411-18305-1 26 JUL 2011 Rev. G



Similar documents
Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Assembly Instruction CAI- Connector with universal Endbell

Solar Kit. Complete solution to optimize your photovoltaic system

Universal MATE-N-LOK Connectors

HT-0095 Mini PV Receptacles AWG Crimping Hand Tool. Tool P/N HT-0095

Enphase Engage Cable and Accessories

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

HARAX circular connector

Waterproof Connectors for Outdoor Use

Power Supply Cables and Connectors

AMPSEAL* Automotive Plug Connector and Header Assembly

gesis IP + Heavy Duty Class I, Zone 2

Directory chapter 04

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

UTS discrete wire sealing

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

SOURIAU s discrete wire sealing

400 Series Buccaneer BUCCANEER POWER. bulgin

HAND CRIMP TOOL Specification Sheet Order No

AMERBRITE UNDERWATER WHITE LED POOL LAMP

INSTALLATION INSTRUCTIONS: Viewline 85 mm

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

INSTALLATION INSTRUCTIONS: Viewline 52 mm

picomax The Pluggable Connection System

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Mini USB and USB 2.0-IP67 Connector System

Advantium 2 Plus Alarm

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

08. SEK IDC CONNECTORS

Front brakes (FN- 3), servicing

Fitting Instruction: Daytona 675 Street Triple from VIN , Street Triple R from VIN A

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Cooling system components, removing and installing

400 Series - Mini USB Buccaneer

LIEBERT VNSA Installation Sheet

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

7000 Series Buccaneer

Position Cat5e (EMT) Modular Plug Connectors. Application Specification

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Explosion proof enclosures

MODEL T200-F18 MODEL T125-F18 Finish Nailers

Trapezoidal-Connectors Series TMC

Quick Reference Guide Euro Style Terminal Blocks

Elektromotoren und Gerätebau Barleben GmbH

GPS AutoSteer System Installation Manual

SMS - Qikmate. Performance characteristics

CutMaster Major External Replacement Parts

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Part Name/Description Part Number Quantity. Power Cable

TOYOTA TACOMA HANDS FREE BLU LOGIC Preparation

2003 Audi A4. AUDI' '3.0L V6 - AVK Engine - A4 & A6

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

CutMaster Major External Replacement Parts

GENUINE PARTS INSTALLATION INSTRUCTIONS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

758 Heavy-duty Ratchet Guy Wire Cutter

Switches and Indicators. Swisstac

Universal MATE-N-LOK Connector System

HAND CRIMP TOOL M22520/2-01

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

MCR1900 Media Converter 19-Slot Chassis

.093 [2.36] Commercial Pin and Socket Connectors

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

4RU High Density Shelf Installation Instructions

Relay mounting systems

CAM-03, Camshaft Assembly Oil Seal Replacement

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Application Tooling Specification Sheet

B 246 Assembly instructions

gesis DC SOLAR Connector System for Solar Power Installations Solar Power is Pluggable

Glenair Military and Industrial Power and Signal Connectors

EPIC CIRCON M23 Series Circular Signal Connectors

XL PREMIUM OIL COOLER KIT

Plug and Socket Devices CES 63 A Series 8579

Elektromotoren und Gerätebau Barleben GmbH

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Submersion/Insertion Toroidal Sensor

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Reasons for reissue are in Section 6, REVISION SUMMARY.

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

V Installation instructions, accessories. Digital radio DAB. Volvo Car Corporation Gothenburg, Sweden. V70 (08-) 2011 Volvo Cars Europe

PowerLine. Single Pole Connectors

Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

POWERPOLE CONNECTOR GENERAL INSTALLATION TIPS

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal.

Transcription:

1. Introduction This instruction sheet covers the installation and termination of the SOLARLOK* connectors and accessory. 2. Supporting Documents 2.1. Customer Drawings Dimensions and material specifications for this product can be found in the following customer drawings PN 1394461 Photovoltaic Connector Pin 1 pos. PN 1394462 Photovoltaic Connector Socket 1 pos. PN 1534226 Interlock Clip PN 2106207 SOLARLOK Locking Collar (UL / NEC Certified) PN 1534611, PN 1740277 T-Distributor 2.2. Product Specification Performance results for the SOLARLOK products can be found in Product Specification 108-18701. 2.3. Application Specification 3. Tools Connectors shall be assembled per Application Specifications 114-18488-1, to ensure correct connector assembly and crimp quality. Please refer to SOLARLOK Application Specification 114-94061 for additional details on contact termination. The following tools are available for the contact crimping: Table 1 Pos. Nr. Tyco Electronics- Part number Wire Size Approval Order text 1 4-1579002-2 2.5 + 4.0 + 6.0 mm² N/A SOLARLOK insulating Stripper 2 1-1579004-1 2.5 mm² 3 1-1579004-2 4.0 + 6.0 mm² 4 0-1579004-8 2.5 + 4.0 + 6mm (Alternativ to Pos 2 und 3). 5 1-1102855-3 For all wire sizes N/A Ejection Tool 6 0-1579000-4 For all wire sizes N/A Adapter for Crimphead (To use with the Electric Terminator CS200) 7 539630-1 For all wire sizes / UL Electric Terminator CS 200 8 7-1579001-8 2,5 mm² Crimp head for SOLARLOK screw machined contacts 9 7-1579001-9 4.0 + 6,0 mm² Crimp head for SOLARLOK screw machined contacts 10 2-1579005-1 Recommended for 2.5 mm² Basic Tool short (to use as hand tool together N / A wire size with a Crimphead (Pos 8) 11 2-1579005-2 Recommended for 4-6 mm² Basic Tool long (to use as hand tool together N / A wire size with a Crimp head (Pos 9) 12 1-1579004-8 AWG 14 UL 13 1-1579004-9 AWG 12 UL 14 2-1579004-0 AWG 10 UL 15 1534858 N / A N / A SOLARLOK Field Service Kit 16 5-1579010-4 N / A N / A SOLARLOK Installer Starter Kit, Standard 1 of 7

4. Accessories 4.1. T-Distributor The T-Distributor is used for connecting a parallel circuit or coupling. Take care to ensure that the max. overall current is not exceed. The T-Distributer must always be fully completely connected! CAUTION: Do not disconnect the connector under load (see 5.3.4)! Disconnect circuit from load before unplugging connectors. Cable assemblies should be labeled using Label 1718077-1. 4.2. Interlock Clip and SOLARLOK Locking Collar For application of the interlock clip and the application of the SOLARLOK Locking Collar see Instruction Sheet 408-10296 Figure 1 a: Figure1b: 5. Assembly Procedure for SOLARLOK Plug connector CAUTION: This connector must be used only to interconnect firmly fixed cables. Do not disconnect under load. Current path must only be disconnected using approved disconnect devices. Cable assemblies shall be labeled with PN 1718077-1. To protect against shock, ensure that conductors and their associated connectors are separated from opposite polarity components. 5.1. Caution any kind of pollution (dust, humidity, etc.) during the assembly process can degrade contact and connector performance. This applies in particular to the seals and the crimping of the contacts. A clean/dry assembly environment is therefore essential. 5.2. Termination of the cable wires / crimping of the contacts The connectors accept different contacts for various wire gauges. Possible wire gauges are 2.5 mm², 4.0 mm² and 6mm² (6mm² only Tyco Electronics Solar wire), 14 AWG, 12 AWG, and 10 AWG. The tools to be used are selected based upon the wire gauge. For the application specification, please refer to 114-94061. 2 of 7

To identify the needed contact Part Number (See the following Table 2) Only Cables released from Tyco Electronics are permitted to use with SOLARLOK Components! For further information, please refer to TE Application Specification 114-94061. Table 2 Available Crimp Contacts for Wire Gauges Pin Contact Socket Contact SOLARLOK Crimp Tool 2.5 mm² 0-1987280-1; or * 4-1105300-1 1987281-1; or * 4-1105301-1 2.5 mm² 4 mm² 0-1987280-2; or * 5-1105300-1 1987281-2; or * 5-1105301-1 4 mm² 6.0 mm² 0-1987280-4; or * 7-1105300-2 1987281-3; or * 7-1105301-2 6 mm² 14 AWG 0-1987280-1; or * 4-1105300-1 1987281-1; or * 4-1105301-1 14 AWG 12 AWG 0-1987280-2; or * 5-1105300-1 1987281-2; or * 5-1105301-1 12 AWG 10 AWG 0-1987280-4; or * 7-1105300-2 1987281-3; or * 7-1105301-2 10 AWG * ) Part Number outdated 5.3. Assembling of the Connectors The usage of any type of lubricant or oil is not allowed! Unconnected connectors must always be protected from pollution (e.g. dust, humidity, foreign particle, etc.). The usage of Tyco Electronics Dust caps is recommended (refer to Application Specification 114-18488 for details). In case of replacement of cables or components or of assembling / disassembling of the cable entry gland, new pinch rings and seals have to be used. If a visible deformation appears at the clamping area of the cable, the cable end needs to be trimmed to remove the deformed area. 3 of 7

5.3.1 Selection of Cable Connectors The cable connectors are delivered as Kits, containing all necessary parts including the Crimp Contacts. There are different Cable Connector Kits available. The correct Kit selection needs to be done according to the Outside Diameter of the cable, Wire Gauge and Polarity (See the followings Table 3) Only Cables released from Tyco Electronics are permitted to use with SOLARLOK Components! For further information, please refer to TE Application Specification 114-94061. Table 3 Available Connector Kits for Wire Gauges Polarity Male Female Cable Diameter Pinch Ring Style 2.5 mm² + 0-1394461-1 0-1394462-1 2.5 mm² - 0-1394461-2 0-1394462-2 2.5 mm² N 6-1394461-1-4.0 mm² + 0-1394461-3 0-1394462-3 4.0 mm² - 0-1394461-4 0-1394462-4 4.0 mm² N 6-1394461-2-6.0 mm² + 6-1394461-5 5-1394462-5 6.0 mm² - 6-1394461-6 5-1394462-6 6.0 mm² N 6-1394461-4 - Cable Diameter (Outside) from 5.5mm up to 7.8mm 1987056-1 2.5 mm² + 0-1394461-7 4-1394462-6 2.5 mm² - 0-1394461-8 4-1394462-7 2.5 mm² N 6-1394461-3-4.0 mm² + 7-1394461-0 4-1394462-8 4.0 mm² - 7-1394461-1 4-1394462-9 4.0 mm² N 7-1394461-2 - Cable Diameter (Outside) from 4.5mm up to 5.5mm 1740379-2 When assembling the connectors, the following sequence must be followed: 5.3.2 Stripping the Wire (see Application Spec. 114-94061 (see Fig. 3) 9mm ±1mm Figure 3 5.3.2.1 Insert the stripped wire into the wire crimp barrel until it stops. While holding the wire in place, squeeze tool handles together until ratchet releases (see Fig. 4) Figure 4 4 of 7

For further information, please refer to TE Application Specification 114-94061. Make sure that the contact is correctly positioned in the applicator or hand tool. For easier handling, use the locator. For pre-assembled connectors, start with chapter 5.3.2.4 5.3.2.2 Press seal into the connector housing until it stops (see Fig. 5 and 6). Figure 5 Components of connector housing Figure 6 Pre assembled seal 5.3.2.3 Screw backshell nut onto connector housing (2 to 3 turns max. see Fig. 7) Figure 7 Assembled Connector Housing 5.3.2.4 Push contact with cable into the connector housing until you hear the contact click into plastic housing; pull back slightly to ensure the contact is locked (Figure 8) Figure 8 Contact assembly 5.3.2.5 Screw backshell nut with a torque wrench with slotted insert (TE-PN: 523229-1) onto the connector housing. Tighten backshell nut to an initial torque of max. 1.3 +0.2 Nm (see Fig. 9 and 10) Figure 9 Figure 10 Tighten back shell nut to a initial torque of max. 1.3 +0.2 Nm Label female connector with label Do not disconnect under load. 5 of 7

5.3.3 Connector Mating When mating the SOLARLOK connectors, ensure the following: Connectors labeled with a + or are keyed and can only be mated to similarly marked and keyed connectors. Caution: The neutral designated pin-connectors incorporate no keying features and may be freely mated to either + or keyed female connectors. The neutral product must not be used where maintaining polarity is critical. It is only admitted for serial connections. At Solarlock interconnection System the usage of the neutral designed pin connector is only necessary for the Junction box termination The polarity of the "neutral" connector must be labeled with PN 1718078-1 or -2 nearby the connector. When mating the connector, the following must always be followed: The plus- and minus-coded connectors can only be mated to a similarly coded connector (see Fig. 10). The connector is fully latched only when the latches are flush with the mating connector. Figure 11 (Female connector) 5.3.4 Disconnecting CAUTION: Unplugging Under Load Not Permitted: PV plug connections must not be un-plugged while under load. They can be placed in an unloaded state e.g. by switching off the DC/AC converter or breaking the AC circuit. Plugging and unplugging while under tension is not permitted. Cable assemblies must be labeled using Label PN 0-1718077-1. Unmating of the connector: Figure 12 1. The locking mechanism is opened by depressing the latches as shown in Figure 11. 2. While depressing the latches, disconnect the connector by pulling the connectors halves apart. 6 of 7

5.3.5 Cable Routing A minimum bending radius R 5 x cable diameter must be maintained. The cable must be routed in a way that the tensile stress on the conductor or connections is prevented. 6. Maximum operating conditions max. system voltage: 1000V (for UL 600V) max. current: 25A at 85 C operating temperature: -40 C up to 115 C Ambient temperature (per IEC 85 C / per UL 75 C) plus temperature rise caused by current 7 of 7