CHAPTER 2 : DC METERS



Similar documents
MEASURING INSTRUMENTS. By: Nafees Ahmed, Asstt, Prof, EE Deptt, DIT, Dehradun

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

1. The diagram below represents magnetic lines of force within a region of space.

Navy Electricity and Electronics Training Series

HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Lab 8: DC generators: shunt, series, and compounded.

Motor Fundamentals. DC Motor

Ammeter design. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Essential Electrical Concepts

Chapter 22: Electric motors and electromagnetic induction

Current and Voltage Measurements. Current measurement

DIRECT CURRENT GENERATORS

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Lab E1: Introduction to Circuits

Motors and Generators

Direct Current Motors

Induced voltages and Inductance Faraday s Law

Linear DC Motors Magnetic Flux Permanent Bar Magnets

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

Electrical Measuring Instruments

Chapter 11. Inductors ISU EE. C.Y. Lee

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Slide 1 / 26. Inductance by Bryan Pflueger

Basic voltmeter use. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

DC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Ampere's Law. Introduction. times the current enclosed in that loop: Ampere's Law states that the line integral of B and dl over a closed path is 0

The DC Motor/Generator Commutation Mystery. Commutation and Brushes. DC Machine Basics

ECEN 1400, Introduction to Analog and Digital Electronics

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

Experiment NO.3 Series and parallel connection

Experiment : Ammeter, Voltmeter, and Ohmmeter. I. Purpose: II. Principle:Major referred web site:

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Resistance, Ohm s Law, and the Temperature of a Light Bulb Filament

Lab 3 - DC Circuits and Ohm s Law

STUDY GUIDE: ELECTRICITY AND MAGNETISM

Magnetic electro-mechanical machines

Bipolar Transistor Amplifiers

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Electrical Fundamentals Module 3: Parallel Circuits

Magnetic Fields and Their Effects

ElectroMagnetic Induction. AP Physics B

5. Measurement of a magnetic field

AP Physics Electricity and Magnetism #4 Electrical Circuits, Kirchoff s Rules

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

Chapter 7. Magnetism and Electromagnetism ISU EE. C.Y. Lee

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Inductors & Inductance. Electronic Components

Chapter 22 Further Electronics

Transistor Amplifiers

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

Lesson 3 DIRECT AND ALTERNATING CURRENTS. Task. The skills and knowledge taught in this lesson are common to all missile repairer tasks.

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Building the HVPS High Voltage Power Supply

Line Reactors and AC Drives

4 LEAD DEDICATED SINGLE PHASE LIMA MAC GENERATOR MODELS 250MSL1185 AND 250MSL1152

OPERATIONAL AMPLIFIER

CHAPTER 28 ELECTRIC CIRCUITS

W03 Analysis of DC Circuits. Yrd. Doç. Dr. Aytaç Gören

Series and Parallel Circuits

Kirchhoff s Laws Physics Lab IX

Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance

Chapter 7 Direct-Current Circuits

Introduction to Electricity & Magnetism. Dr Lisa Jardine-Wright Cavendish Laboratory

Resistors. Some substances are insulators. A battery will not make detectible current flow through them.

4 DEDICATED SINGLE PHASE LIMA MAC GENERATOR LIGHT TOWER DUTY MODELS 250MSL1278 AND 250MSL1299 SERVICE PROCEDURE ELECTRICAL COMPONENT TESTING

13 ELECTRIC MOTORS Basic Relations

DC MOTOR ANALYSIS & TROUBLESHOOTING

Electronics. Basic Concepts. Yrd. Doç. Dr. Aytaç GÖREN Yrd. Doç. Dr. Levent ÇETİN

= V peak 2 = 0.707V peak

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

EXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

Measuring Electric Phenomena: the Ammeter and Voltmeter

WINDING RESISTANCE TESTING

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

Understanding the Alternator

V out. Figure 1: A voltage divider on the left, and potentiometer on the right.

Objectives 200 CHAPTER 4 RESISTANCE

Lab 14: 3-phase alternator.

Eðlisfræði 2, vor 2007

The full wave rectifier consists of two diodes and a resister as shown in Figure

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Episode 126: Capacitance and the equation C =Q/V

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

Chapter 3. Diodes and Applications. Introduction [5], [6]

Objectives. Capacitors 262 CHAPTER 5 ENERGY

101 BASICS SERIES LEARNING MODULE 2: FUNDAMENTALS OF ELECTRICITY. Cutler-Hammer

Unit/Standard Number. High School Graduation Years 2010, 2011 and 2012

Measurement and Instrumentation. Analog Electrical Devices and Measurements

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

ELECTRODYNAMICS 05 AUGUST 2014

ANALOG AND DIGITAL METERS ANALOG VS. DIGITAL METERS VOLTMETERS ANALOG AND DIGITAL

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Transcription:

EE 101 MEASUREMENT DC Meter / 1 CHAPTER 2 : DC METERS 2.1 BASIC PRINCIPLE OF ANALOG METER This permanent magnet moving coil meter movement is the basic movement in most analog (meter with a pointer indicator hand) measuring instruments. It is commonly called d'arsonval movement because it was first employed by the Frenchman d'arsonval in making electrical measurements. This type of meter movement is a current measuring device which is used in the ammeter, voltmeter, and ohmmeter. Basically, both the ammeter and the voltmeter are current measuring instruments, the principal difference being the method in which they are connected in a circuit. While an ohmmeter is also basically a current measuring instrument, it differs from the ammeter and voltmeter in that it provides its own source of power and contains other auxiliary circuits. 2.1.1 Basic Principle Operation Of Permanent-Magnetic Moving-Coil Movement a) Basic Construction b) The Permanent-Magnetic Moving-Coil Movement Used In A Meter. Figure 2.1 : Permanent-Magnetic Moving-Coil

EE 101 MEASUREMENT DC Meter / 2 The compass and conducting wire meter can be considered a fixed-conductor moving-magnet device since the compass is, in reality, a magnet that is allowed to move. The basic principle of this device is the interaction of magnetic fields: the field of the compass (a permanent magnet) and the field around the conductor (a simple electromagnet). A permanent-magnet moving-coil movement is based upon a fixed permanent magnet and a coil of wire which is able to move, as in figure 2.2. When the switch is closed, causing current through the coil, the coil will have a magnetic field which will react to the magnetic field of the permanent magnet. The bottom portion of the coil will be the north pole of this electromagnet. Since opposite poles attract, the coil will move to the position shown in figure 2.3. Figure 2.2 : A movable coil in a magnetic field (with current). Figure 2.3. : A movable coil in a magnetic field (no current). The coil of wire is wound on an aluminum frame, or bobbin, and the bobbin is supported by jeweled bearings which allow it to move freely. This is shown in figure 2.4. To use this permanent-magnet moving-coil device as a meter, two problems must be solved. First, a way must be found to return the coil to its original position when there is no current through the coil. Second, a method is needed to indicate the amount of coil movement. The first problem is solved by the use of hairsprings attached to each end of the coil as shown in figure 2.5. These hairsprings can also be used to make the electrical connections to the coil. Figure 2.4. : A basic coil arrangement. Figure 2.5. : Coil and hairsprings.

EE 101 MEASUREMENT DC Meter / 3 With the use of hairsprings, the coil will return to its initial position when there is no current. The springs will also tend to resist the movement of the coil when there is current through the coil. When the attraction between the magnetic fields (from the permanent magnet and the coil) is exactly equal to the force of the hairsprings, the coil will stop moving toward the magnet. As the current through the coil increases, the magnetic field generated around the coil increases. The stronger the magnetic field around the coil, the farther the coil will move. This is a good basis for a meter. But, how will you know how far the coil moves? If a pointer is attached to the coil and extended out to a scale, the pointer will move as the coil moves, and the scale can be marked to indicate the amount of current through the coil. This is shown in figure 2.6. Figure 2.6. - A complete coil. Figure 2.7 : Complete Construction of Permanent Magnet Moving Coil (PMMC) Two other features are used to increase the accuracy and efficiency of this meter movement. First, an iron core is placed inside the coil to concentrate the magnetic fields. Second, curved pole pieces are attached to the magnet to ensure the turning force on a coil increases steadily as the current increases. These same curved pole pieces are found in a motor. 2.1.3. Deflection Torque It has been mentioned that interaction between the induced field and the field produced by the permanent magnet causes a deflecting torque, which results in rotation of the coil. Deflection torque is controlling torque controls the deflection and tries to stop the pointer at its final position. But due to inertia, the pointer oscillates around its final position before coming to rest. Hence damping torque is provided to avoid this oscillation and bring the pointer quickly to its final position.

EE 101 MEASUREMENT DC Meter / 4 Thus the damping torque is never greater than the controlling torque. In fact it is the condition of critical damping which is sufficient to enable the pointer rising quickly to its deflected position without overshooting. The deflecting torque produced is described below in mathematical form: Deflecting Torque, T d = BINA (Equation 2.1) Where B = flux density in Wb/m 2 (Tesla) I = current (A). N = number of turns of the coils. A = area ( length X wide), (m 2 ). Example 1: Given frame of permanent moving coil is 6m 2. The number of winding around coil is 50 and flux 0.12 wb/m 2. If 1mA current through the coil, calculate the deflection torque. Solution T d = BINA = (0.12 wb/m 2 )( 1mA)(50)(6m 2 ) = 36mNm 2.1.5 Damping A problem that is created by the use of a rectifier and d Arsonval meter movement is that the pointer will vibrate (oscillate) around the average value indication. In physics, damping is any effect that tends to reduce the amplitude of oscillations in an oscillatory system, particularly the harmonic oscillator. This oscillation will make the meter difficult to read. The process of "smoothing out" the oscillation of the pointer is known as DAMPING. There are two basic techniques used to damp the pointer of a d Arsonval meter movement. i. The first method of damping comes from the d Arsonval meter movement itself. In the d Arsonval meter movement, current through the coil causes the coil to move in the

EE 101 MEASUREMENT DC Meter / 5 magnetic field of the permanent magnet. This movement of the coil (conductor) through a magnetic field causes a current to be induced in the coil opposite to the current that caused the movement of the coil. This induced current will act to damp oscillations. In addition to this method of damping, which comes from the movement itself, most meters use a second method of damping. ii. The second method of damping used in most meter movements is an airtight chamber containing a vane (like a windmill vane) attached to the coil. As the coil moves, the vane moves within the airtight chamber. The action of the vane against the air in the chamber opposes the coil movement and damps the oscillations. There are two general classes of damped motion, as follows: 1. Periodic, in which the pointer oscillates about the final position before coming to rest. 2. Aperiodic, in which the pointer comes to rest without overshooting the rest position. The point of change between periodic and aperiodic damping is called "critical damping." An instrument is considered to be critically damped when overshoot is present but does not exceed an amount equal to one half the rated accuracy of the instrument. A problem that is created by the use of a rectifier and d Arsonval meter movement is that the pointer will vibrate (oscillate) around the average value indication. This oscillation will make the meter difficult to read. The value of the damping ratio ζ determines the behavior of the system. A damped harmonic oscillator can be: i. Critical damping (ζ = 1) When ζ = 1, there is a double root γ (defined above), which is real. The system is said to be critically damped. A critically damped system converges to zero faster than any other, and without oscillating. An example of critical damping is the door closer seen on many hinged doors in public buildings. The recoil mechanisms in most guns are also critically damped so that they return to their original position, after the recoil due to firing, in the least possible time. ii. Over-damping (ζ > 1) When ζ > 1, the system is over-damped and there are two different real roots. An overdamped door-closer will take longer to close than a critically damped door would iii. Under-damping (0 ζ < 1) Finally, when 0 ζ < 1, γ is complex, and the system is under-damped. In this situation, the system will oscillate at the natural damped frequency ωd, which is a function of the

EE 101 MEASUREMENT DC Meter / 6 natural frequency and the damping ratio. To continue the analogy, an underdamped door closer would close quickly, but would hit the door frame with significant velocity, or would oscillate in the case of a swinging door. Figure 2.8 : Damping Curve

EE 101 MEASUREMENT DC Meter / 7 2.1.6 Common Damping System In Indicating Instrument a. Air friction damping Figure 2.9 : Air Friction Damping. b. Liquid damping Similar principle as air damping only the vane moves in a liquid chamber with a proper concentration. c. Eddy current damping Eddy currents are currents induced in conductors to oppose the change in flux that generated them. It is caused when a conductor is exposed to a changing magnetic field due to relative motion of the field source and conductor; or due to variations of the field with time. This can cause a circulating flow of electrons, or a current, within the body of the conductor. These circulating eddies of current create induced magnetic fields that oppose the change of the original magnetic field due to Lenz's law, causing repulsive or drag forces between the conductor and the magnet. The stronger the applied magnetic field, or the greater the electrical conductivity of the conductor, or the faster the field that the conductor is exposed to changes, then the greater the currents that are developed and the greater the opposing field.

EE 101 MEASUREMENT DC Meter / 8 Figure 2.12 : Eddy Current Damping 2.2 DC VOLTMETER A basic d Arsonval movement can be converted into dc voltmeter by adding in series resistor multiplier as shown in figure 2.9. Figure 2.9 : DC Voltmeter circuit. I M R M R S V = full scale deflection current of the movement (I fsd) = internal resistance of the movement = multiplier resistance = full range voltage of the instrument Current in series; I S = I M (Equation 2.2) From Ohm Law; V = I M (R S + R M) = I M R S + I MR M (Equation 2.3)

EE 101 MEASUREMENT DC Meter / 9 (Equation 2.4) Exercise 2 A basic D Arsonval movement with a full-scale deflection of 50 µa and internal resistance of 500Ω is used as a DC voltmeter. Determine the value of the multiplier resistance needed to measure a voltage range of 0-10V. Solution: = 500Ω = 50 ua

EE 101 MEASUREMENT DC Meter / 10 2.2.3 Multi-Range Voltmeter A DC voltmeter can be converted into a multirange voltmeter by connecting a number of resistors (multipliers) in series with the meter movement. A practical multi-range DC voltmeter is shown in Figure 2.6. R 1 R 2 R m V 1 V 2 + I m _ Figure 2.10 : DC Multi-range Voltmeter circuit. (Equation 2.5) (Equation 2.6) (Equation 2.7) Exercise 3 Convert a basic D Arsonval movement with an internal resistance of 100Ω and a full scale deflection current of 1mA into a multirange dc voltmeter with voltage ranges of 0-15V and 0-50V. Solution i. Range 0 15V = 15KΩ Ω

EE 101 MEASUREMENT DC Meter / 11 ii. Range 0 50V Ω Ω 2.2.7 Loading Effects in DC Voltmeter When a voltmeter is used to measure the voltage across a circuit component, the voltmeter circuit itself is in parallel with the circuit component. Total resistance will decrease, so the voltage across component will also decrease. This is called voltmeter loading. The resulting error is called a loading error. The voltmeter loading can be reduced by using a high sensitivity voltmeter. The exercise below can show the loading effect when using voltmeter with two value sensitivity. Exercise 4 R 1 = 200KΩ 200 R 2 = 50KΩ v Find the voltage across the resistor 50KΩ as shown in figure above if using a. Voltmeter with sensitivity 1000Ω/V b. Voltmeter with sensitivity 20000Ω/V And voltmeter range for both measurements is 0 50V.

EE 101 MEASUREMENT DC Meter / 12 Solution a. At range 50V and the sensitivity voltmeter is 1000Ω/V Actual voltage value across R 2, Ω Ω Ω R 2 V 2 = -------- X V R 1 + R 2 = 40 V Analysis voltmeter with sensitivity 1000Ω/V across R 2. Impendent voltmeter, R in = V (range) x sensitivity = 50V x 1000 Ω/V = 50KΩ When voltmeter connected, the resistance in circuit as s how in figure R 1 = 200KΩ R voltmeter 200V R 2 = 50KΩ V R in = 50KΩ R eq = ------------------ R 2 selari dengan R in The circuit can be simplify as show in figure below R 1 = 200KΩ 200V R eq = 25KΩ Ω

EE 101 MEASUREMENT DC Meter / 13 So, the reading at voltmeter is Voltage across R eq, V b. At range 50V and sensitivity voltmeter is 20000Ω/V The calculation actual voltage value across R 2 is same with a. Analysis voltmeter with sensitivity 20000Ω/V across R 2. Impendent voltmeter, R in = V (range) x sensitivity = 50V x 20000 Ω/V = 1MΩ

EE 101 MEASUREMENT DC Meter / 14 When voltmeter connected, the resistance in circuit as show in figure R 1 = 200KΩ R voltmeter 200V R 2 = 50KΩ V R in = 1MΩ R 2 selari dengan R in The circuit can be simplify as show in figure below R 1 = 200KΩ 200V So, the reading at voltmeter is R eq = 47.62KΩ Ω Voltage across R eq, V =

EE 101 MEASUREMENT DC Meter / 15 2.3 DC AMMETER The PMMC galvanometer constitutes the basic movement of a dc ammeter. The coil winding of a basic movement is small and light, so it can carry only very small currents. The PMMC can use to build an ammeter with connected the shunt resistor and meter in parallel. A low value resistor (shunt resistor) is used in DC ammeter to measure large current. Basic DC ammeter: I I M R M I SH R SH Figure 2.11 : DC Ammeter circuit. R M R SH I SH I M I = internal resistance of the movement = shunt resistance =shunt current = full scale deflection current of the movement = full scale current of the ammeter + shunt (i.e. total current) * R SH is smaller than R M (Equation 2.8) (Equation 2.9) (Equation 2.10) From Ohm s Laws Therefore (Equation 2.11)

EE 101 MEASUREMENT DC Meter / 16 Exercise 5 A 1mA meter movement with an internal resistance of 100Ω is to be converted into a 0-100 ma. Calculate the value of shunt resistance required. Solution Ω = 1.01Ω 2.3.3 Multirange Ammeter Individual Shunt The range of the dc ammeter is extended X by a number of shunts, selected by a range switch. The resistors are placed in parallel to give different current ranges. Switch S (multiposition switch) protects the meter movement from being damage during range changing. a. Individual Shunts I I M R M I SH R SH1 S R SH2 R SH3 R SH4 Figure 2.12 : Individual Shunt circuit. (Equation 2.12)

EE 101 MEASUREMENT DC Meter / 17 b. Ayrton Shunt Julat 10mA R 2 R SHT Julat 100mA R 1 R SH1 R M = 50Ω I M = 2 ma Figure 2.13 : Individual Ayrton Shunt circuit. Total shunt resistor, R SHT = R 2 + R 1 (Equation 2.13) Total resistor, R T = R SHT + R M (Equation 2.14) # To calculate the total shunt resistor, determine from the lowest range. R SHT = (.. + R n + R 2 + R 1) = (Equation 2.15) # To calculate another R SH, start from the highest range. (Equation 2.16) Exercise 6 Refer the circuit above, calculate shunt resistor ( R 1 and R 2) when using range - 10mA and 100mA. Solution To find total shunt resistor use the lowest range 10mA. R SHT = (R 2 + R 1) = Ω = 12.5Ω. For shunt resistor at 100mA (highest range) Ω

EE 101 MEASUREMENT DC Meter / 18 Ω Ω Ω 2.4 OHMMETER The PMMC can change to be ohmmeter with connected voltage source and limited current resistor in series. The type of Ohmmeter is series ohmmeter and parallel ohmmeter. The purpose of an ohmmeter is to measure the resistance placed between its leads. This resistance reading is indicated through a mechanical meter movement which operates on electric current. 2.4.1 Series Ohmmeter R 1 = Limited Current Resistor R 2 = Zero Adjust Resistor R x = unknown Resistance R m = Meter Resistance V Figure 2.14 : Individual Series Ohmmeter circuit. R 2 R 1 R m A B R x Operation of Series Ohmmeter When R x = 0 ( AB terminal short), the current in circuit is maximum and the pointer shown the full reading. Adjust the R 2 until the full scale, I M. The pointer at full scale is mark as 0 ohm. When R x = infinity (AB terminal open), the current in circuit is 0. The unknown resistance must connect series with basic meter movement. This circuit use to measure higher resistance and the pointer is mark as infinity. 0Ω Ω AB Terminal Short AB Terminal open Figure 2.15 : The pointer location

EE 101 MEASUREMENT DC Meter / 19 When R x connected; (Equation 2.17) (Equation 2.18) Exercise 7 Given PMMC with resistance 100Ω was using in series ohmmeter. R 1 = 500Ω, R 2 = 400Ω and supply voltage = 10V. When connected with R x, the reading shows 0.5mA. Find the value of R x. Solution R 1 = 500Ω A 10V R m = 100Ω R x R 2 = 400Ω B Ω 2.4.2 Shunt Resistor in Series Type Ohmmeter R 1 = Limited Current Resistor R 2 = Zero Adjust Resistor R x = unknown Resistance R M = Meter Resistance V R M R 1 A R x R 2 B Figure 2.15 : Individual Shunt resistor in series type ohmmeter circuit.

EE 101 MEASUREMENT DC Meter / 20 (Equation 2.19), the ratio between current reading when R x is connected and full scale current. R eq A I FS when R X = 0 ( AB short) V in B where (Equation 2.20) V in R T B A R x I FS when R X is connected (Equation 2.21) Exercise 8 1.5V R 1 R m A R x Movement meter have 100µA FSD. Assume R1 + R2 + Rm = 15KΩ R 2 B a) State the pointer location when Rx = 0. b) State the location for ohmmeter scale at ½ FSD, ¼ FSD and ¾ FSD.

EE 101 MEASUREMENT DC Meter / 21 Solution a) b) At ½ FSD = ½ X 100µA = 50µA. At ¼ FSD = ¼ X 100µA = 25µA. At ¾ FSD = ¾ X 100µA = 75µA.

EE 101 MEASUREMENT DC Meter / 22 2.4.3 Parallel (Shunt) Ohmmeter R 1 R 2 I I x A I m V R x Figure 2.16 : Individual Shunt Ohmmeter circuit. B (Equation 2.22) Operation of Shunt Ohmmeter R 1 I A + I M V in R x - S 1 R M B Figure 2.17 : Operation of Shunt Ohmmeter. S1 is using for cut-off the battery (Vin) when not using the circuit. When Rx = 0 ( AB terminal short), no current in circuit and the pointer is mark as 0 ohm. When Rx = infinity (AB terminal open), the current (I M) in circuit is maximum. Adjust R1 until the meter movement is full scale, and the pointer is mark as Ω (Infinity). Ω 0Ω AB Terminal Open AB Terminal short Figure 2.18 : The pointer location

EE 101 MEASUREMENT DC Meter / 23 Example 9 I = 5µA R 1 = 4.5KΩ I m I x A State the ohmmeter scale when the current is 0A, ½ FSD, ¼ FSD and FSD V R m = 500Ω R x B Solution At 0A scale, At ½ FSD, At ¼ FSD, At FSD, 2.4.4 Function i. Current limiting resistance A resistor inserted in an electrical circuit to limit the flow of current to some predetermined value. It is used chiefly to protect tubes and other components during warm-up. ii. iii. Zero adjusts resistance. A resistor inserted in an electrical circuit to adjusts the value of resistance to zero. Meter resistance A resistance of the meter's armature coil.

EE 101 MEASUREMENT DC Meter / 24 iv. Unknown resistance A resistance that unknown value in a circuit. 2.4.5 Differentiate typical scale in series and shunt type ohmmeter. Scale in Series Type Ohmmeter Scale starts with infinity at left side and zero at right side Scale in Shunt Type Ohmmeter Scale starts with zero at left side and infinity at right side ϖ 0 R1 0 ϖ - R When point A short B, Rx=0 (Maximum current m flows in circuit) so R2 is adjusted for pointer pointing at Rm zero position (which means current only flow through Rm). Normally it known as 'Zero Adjusted'. E R1 R2 E R m When point A short B, Rx=0 (No current flows in meter) so R1 is adjusted to pointing at zero position. Normally it known as 'Zero Adjusted'. A B A B A R1 A R m R2 Open circuit E R m Open circuit E B When point A-B open, Rx=infinity (No current flows in circuit) so pointer is pointing to infinity position. When point A-B open, Rx=infinity (Maximum current flows in meter) so pointer is pointing to infinity position.

EE 101 MEASUREMENT DC Meter / 25 R1 A R1 A R m R2 Rx E R m B When point A-B connecting to unknown Rx to measure resistance value, pointer will point to a certain value proportional to resistance value. E B -When point A-B connecting to unknown Rx to measure resistance value, pointer will point to a certain value proportional to resistance value. B 2.5 ANALOGUE AND DIGITAL MULTIMETER An instrument designed to measure electrical quantities. A typical multimeter can measure alternating- and direct-current potential differences (voltages), current, and resistance, with several full-scale ranges provided for each quantity. 2.5.1 Analogue Multimeter Figure 2.17 : : Schematic circuit analog multimeter

EE 101 MEASUREMENT DC Meter / 26 Range of Ohm, volt and ampere in analogue multimeter a) DC Voltage: 0.5V, 2.5V, 10V, 50V, 250V, 1000V. b) AC Voltage: 10V, 50V, 250V, 1000V. c) DC Current: 50µA, 2.5mA, 25mA, 250mA. A high current range is often missing from this type of meter. d) AC Current: None. (You are unlikely to need to measure this). e) Resistance: 20, 200, 2k, 20k, 200k. These resistance values are in the middle of the scale for each range. Figure 2.18 : Multimeter Range Scale of Ohm, volt and ampere in analogue multimeter Figure 2.19 : Multimeter Scale. Check the setting of the range switch and choose an appropriate scale.

EE 101 MEASUREMENT DC Meter / 27 Sensitivity of meter Sensitivity is define as the accuracy with which a meter can measure a voltage, current, resistance, or other quantity. Multimeters must have a high sensitivity of at least 20k /V otherwise their resistance on DC voltage ranges may be too low to avoid upsetting the circuit under test and giving an incorrect reading. To obtain valid readings the meter resistance should be at least 10 times the circuit resistance (take this to be the highest resistor value near where the meter is connected). If you are buying an analogue multimeter make sure it has a high sensitivity of 20k /V or greater on DC voltage ranges, anything less is not suitable for electronics. The sensitivity is normally marked in a corner of the scale, ignore the lower AC value (sensitivity on AC ranges is less important), the higher DC value is the critical one. Beware of cheap analogue multimeters sold for electrical work on cars because their sensitivity is likely to be too low. Analogue meters take a little power from the circuit under test t to operate their pointer. They must have a high sensitivity of at least 20k /V or they may upset the circuit under test and give an incorrect reading. Analogue meter resistance Analogue meter resistance is refers to resistance in coil winding armature and it can only carry very small currents. Step to do following measurement using multimeter 1. Measure Resistance using analogue multimeter To measure the resistance of a component it must not be connected in a circuit. If you try to measure resistance of components in a circuit you will obtain false readings (even if the supply is disconnected) and you may damage the multimeter. The resistance scale on an analogue meter is normally at the top, it is an unusual scale because it reads backwards and is not linear (evenly spaced). This is unfortunate, but it is due to the way the meter works. Procedure i. Set the meter to a suitable resistance range. Choose a range so that the resistance you expect will be near the middle of the scale. For example: with the scale shown below and an expected resistance of about 50k choose the 1k range. ii. Hold the meter probes together and adjust the control on the front of the meter which is usually labeled "0 ADJ" until the pointer reads zero (on the RIGHT remember!). If you can't adjust it to read zero, the battery inside the meter needs replacing.

EE 101 MEASUREMENT DC Meter / 28 iii. Put the probes across the component. Avoid touching more than one contact at a time or your resistance will upset the reading! 2. Measuring voltage and current with a multimeter i. Select a range with a maximum greater than you expect the reading to be. ii. Connect the meter, making sure the leads are the correct way round. Digital meters can be safely connected in reverse, but an analogue meter may be damaged. iii. If the reading goes off the scale: immediately disconnect and select a higher range. 2.5.2 DIGITAL MULTIMETERS Figure 2.6. Digital Multimeter

EE 101 MEASUREMENT DC Meter / 29 SELECTOR SWITCH Figure 2.6.1. Model 8000A block diagram Digital Multimeter Function of each block Note that the block diagram divides the instrument into three major sections: 1) The SIGNAL CONDITIONING section consist of input divider (resistors connected in series), current shunt (resistor connected in parallel), selector switch, AC Convertor, active filter ( filter AC signal to DC signal. 2) The ANALOGUE-TO- DIGITAL CONVERTER section consist of Analog IC and Digital IC, convert analog input to digital output. 3) The DISPLAY section consist of four LEDs, analog control, decoder driver. The output from Digital IC are in binary number, will past through BCD (Binary Coded Decimal). and decoder driver where the measured value displayed decimal value. Measuring using digital multimeter 1. Measuring voltage using digital multimeter The steps are the same as analogue multimeter, but Digital meters can be safely connected in reverse, but an analogue meter may be damaged. 2. Measuring current using digital multimeter. The steps are the same as analogue multimeter, but Digital meters can be safely connected in reverse, but an analogue meter may be damaged.

EE 101 MEASUREMENT DC Meter / 30 3. Measuring resistance with a DIGITAL multimeter i. Set the meter to a resistance range greater than you expect the resistance to be. Notice that the meter display shows "off the scale" (usually blank except for a 1 on the left). Don't worry, this is not a fault, it is correct - the resistance of air is very high! ii. iii. Touch the meter probes together and check that the meter reads zero. If it doesn't read zero, turn the switch to 'Set Zero' if your meter has this and try again. Put the probes across the component. Avoid touching more than one contact at a time or your resistance will upset the reading! 2.6. DIFFERENTIATE BETWEEN ANALOG AND DIGITAL MULTIMETER 1. An analogue multimeter used scale on moving coil meter to indicate the measured value while a digital multimeter used LEDs Display to display the measured value. 2. An analogue multimeter used resistors (shunt and multiplier) while a digital multimeter used ICs, LEDs, Convertors, decoder driver. 2.7 COMPARE ADVANTANGES AND DISADVANTAGES 1. The sensitivity of analogue multimeter depends on the voltage ranges. All digital meters contain a battery to power the display so they use virtually no power from the circuit under test. This means that on their DC voltage ranges they have a very high resistance (usually called input impedance) of 1M or more, usually 10M, and they are very unlikely to affect the circuit under test. 2. When measuring voltage using digital multimeter. The steps are the same as analogue multimeter, but Digital meters can be safely connected in reverse, but an analogue meter may be damaged. 3. When measuring current using digital multimeter. The steps are the same as analogue multimeter, but Digital meters can be safely connected in reverse, but an analogue meter may be damaged.

EE 101 MEASUREMENT DC Meter / 31 2.5.8 Multimeter safety precaution As with other meters, the incorrect use of a multimeter could cause injury or damage. The following safety precautions are the MINIMUM for using a multimeter. 1. Deenergize and discharge the circuit completely before connecting or disconnecting a multimeter. 2. Never apply power to the circuit while measuring resistance with a multimeter. 3. Connect the multimeter in series with the circuit for current measurements, and in parallel for voltage measurements. 4. Be certain the multimeter is switched to ac before attempting to measure ac circuits. 5. Observe proper dc polarity when measuring dc. 6. When you are finished with a multimeter, switch it to the OFF position, if available. If there is no OFF position, switch the multimeter to the highest ac voltage position. 7. Always start with the highest voltage or current range. 8. Select a final range that allows a reading near the middle of the scale. 9. Adjust the "0 ohms" reading after changing resistance ranges and before making a resistance measurement. 10. Be certain to read ac measurements on the ac scale of a multimeter. 11. Observe the general safety precautions for electrical and electronic devices.