Super Blue Pennant Switchboards Warehouse Stock



Similar documents
ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

IRRIGATION PUMPING Table of Contents - Section 900

Section 10 Electric Switchboards: 0 Through 600 Volts

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Secondary Unit Substations

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Distribution Dry Type Transformers

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

Approved Meter Sockets and Cabinets

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

MCC Ratings. Voltage Rating

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Sentron Series Circuit Breakers

Description. Lugs for NEMA Stud Kits a. (2) #6-350 kcmil SUK350TA (1) #2-600 kcmil SUK600TA. (2) # kcmil SUK1000TA.

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC B S E C W

Selection and application guide. Panelboards. usa.siemens.com/panelboards

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

SPEEDFAX TM 2011 Disconnect Switches Contents

Mini Power-Zone Unit Substation

Corner-Grounded Delta (Grounded B Phase) Systems

Equipment. Metering. Metering Equipment 1. Contents

Sample - No Commercial Use

Power Outlet Panels. Product Guide

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC B S E C W. [previous page #: 2-18; 2-22]

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Temporary Power Outlet Panels. Selection and Application Guide.

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Primary and Secondary Electrical Distribution Systems

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Temporary Power Outlet Panels

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Engineers Edge, LLC PDH & Professional Training

Bolted contact switches. Pringle switches

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

ASCO SERIES 185 Power Transfer Switches

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

tiastar and legacy Motor Control Center Aftermarket Renewal Parts Catalog

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Applications. Remote Display Mounting Kits

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

8146/5 Series Breaker Panelboards

Siemens STEP 2000 Course Basics of Electrical Products

Fusible Disconnect Switch

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Please check with your local inspection authority for any additional requirements before installation.

Electrical Service Guidelines

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

CHAPTER 5 PARTS. This chapter describes assemblies / subassemblies / parts considered replaceable at on-site field installation.

METERING INSTALLATION REQUIREMENTS

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Panelboards 11 PANELBOARDS. Type P2 Panelboards. General

ELEC ELE TR CTRIC P IC PRODUCTS RODUCT

Type 1, 3, & 3R Enclosures

Section 5 Meters and Service Entrance Equipment

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

The following components are common to most cubicles; this example is an ABB HK cubicle.

The Ultimate Load Center Features INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Services. Three Phase Service

Distribution Dry Type Transformers

RAY-MAX Integrated Solar Power Strip

Electrical Service Requirements (ESR)

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Cable/Conduit Conversion

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Customer Metering and Services Guide

LVA Take Offs in Bid Manager

Medium Voltage Motor Control Assemblies

Customer Substation Manual 08/05/02

Introduction. Upon completion of Basics of Electrical Products, you should be able to:

Duke Energy Carolinas. Inverter Based Generation Interconnection

Switchboards DE6 SWITCHBOARDS. Selection Guide. MDS Switchboard. QED Switchboard DE6-1. Description

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Retail Reference Guide Answers for infrastructure.

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Electrical Code Regulation

GE Power Controls. MiniFORM Switchboards

Transcription:

Warehouse Stock Features The Super Blue Pennant service entrance switchboard is designed to meet the needs of main over current protection with distribution devices for medium duty service applications. Main service disconnects can be either Siemens Vacu-Break fusible switch or Siemens molded case circuit breakers. Either type of device provides dependable performance with series rated combinations available. The switchboard is labeled as suitable for use only as service equipment. Super Blue Pennant switchboards meet EUSERC utility requirements. A NEMA Type 1 indoor or Type 3R outdoor self-contained enclosures are constructed of code gauge steel and painted ANSI-61 light gray. B Rating label information is clearly visible on the equipment front panel. Danger, short circuit rating labels and UL listing label present necessary information to conform with NEMA Standard PB-2. C Metering and test block provisions meet EUSERC utility specifications. D Incoming main lugs are mechanical screw-type mounted on studs accepting a wide range of cable sizes. E Barriered hot sequence utility metering and fully bussed power company current transformer compartment meet EUSERC utility standards. F Service disconnect can be fusible Vacu-Break switch through 200,000 AIC or circuit breaker with maximum rating of 65,000 AIC at 240 volts and 50,000 AIC at 480 volts. G Distribution panel kits are optional and field addable with ratings of 400 800 amperes. Up to 40 branch circuit provisions available, 18 branch circuit minimum. High interrupting capacity subfeed kits with molded case circuit breaker ratings of 225 or 400 amperes. Series rated combinations are available. Consult sales office. Contact sales office for warehouse stocking locations. 8 SWITCHBOARDS Ampere Ratings 400 600 800 Ampere Circuit Breaker Main 400 600 Ampere Fusible Vacu-Break Main Voltage Ratings 120/240 Volts 1 Phase, 240/120 Volts 3 Phase, Delta 240 Volts 3 Phase, Delta 208Y/120 Volts 3 Phase, 480Y/277 Volts 3 Phase, 480 Volts 3 Phase, Delta I.C. Ratings The short circuit current rating is limited to the lowest current interrupting rating, at the supply voltage, of any device installed. Only Siemens breakers with short circuit interrupting ratings equal to or greater than the marked short circuit current rating shall be used for replacement or additions. 8-5

Type 1 Indoor, Type 3R Outdoor Type 1 Indoor Type 3R Outdoor Weatherproof SWITCHBOARDS 8 ( ) ( ) ( ) 26.25" 26.25" 3.875" 5.875" 3.875" 14.5" 12.5" 8.75" 14.5" 14.5" 12.5" 8.75" 14.5" 15.625" Dimensions (inches) Description A B C Without Lug Landing 46 14 12 With Lug Landing 58 26 24 Dimensions (inches) Description A B C Without Lug Landing 53 15 13 With Lug Landing 65 27 25 8-6

Main Circuit Breaker Main Circuit Breaker Main Device Meter Distribution Approximate Ampere Service Catalog Number List Price $ Socket Kits Weight (lbs.) Rating Voltage Indoor Outdoor Indoor Outdoor Clips Available Indoor Outdoor 400 Ampere Breaker Rated 65,000A IR at 240 Volts 35,000A IR at 480 Volts Type JD6 PB224 WPB224 3411.00 6023.00 5 PQ2612 Delta 240; 3 Phase, PQ4630 PB424 WPB424 4259.00 6821.00 15 PE4630 PB444 WPB444 5839.00 8423.00 15 320 1050 8 SWITCHBOARDS 600 Ampere Breaker Rated 65,000A IR at 240 Volts 35,000A IR at 480 Volts Type LD6 PB226 WPB226 4365.00 6943.00 5 PQ2612 Delta 240; 3 Phase, PB426 WPB426 5946.00 8530.00 15 PB446 WPB446 8923.00 11534.00 15 PQ4630 PE4630 320 1050 800 Ampere (3) 3 0-500 Breaker Rated 65,000A IR at 240 Volts 50,000A IR at 480 Volts Type MD6 120/240; 1 Phase, PQ2840 PB228 WPB228 5632.00 8224.00 5 PQ2816 Delta 240; 3 Phase, PB428 WPB428 7712.00 10310.00 15 PQ4840 PQ4818 PE4840 PB448 WPB448 11847.00 14420.00 15 PF4809 460 1090 475 1090 475 1090 Price does not include load side lugs, Distribution Panel or Subfeed Kits. For 6-jaw requirements, order 6th clip kit from accessories. Refer to Distribution Panel Kits for list prices. Discount Schedule A 8-7

Main Fusible Switch Main Fusible Switch SWITCHBOARDS 8 Main Device Meter Distribution Approximate Ampere Service Catalog Number List Price $ Socket Kits Weight (Lbs) Rating Voltage Indoor Outdoor Indoor Outdoor Clips Available Indoor Outdoor PF224 WPF224 4001.00 6430.00 5 PQ2612 365 1094 400 Ampere 375 1110 200,000 AIC maximum at 600 Volts 600 Ampere 200,000 AIC maximum at 600 Volts Delta 240; 3 Phase, PQ4630 PF424 WPF424 4877.00 7428.00 15 PE4630 PF444 WPF444 5718.00 8089.00 15 PF226 WPF226 4907.00 7604.00 5 PQ2612 Delta 240; 3 Phase, PQ4630 PF426 WPF426 6764.00 9314.00 15 PE4630 PF446 WPF446 8709.00 11093.00 15 375 1110 370 1100 390 1110 390 1120 Fuses not included. Price does not include load side lugs, Distribution Panel or Subfeed Kits. For 6-jaw requirements, order 6th clip kit from accessories. Refer to Distribution Panel Kits for list prices. Discount Schedule A 8-8

Components Main Device (Circuit Breaker or Fusible Switch) Load Side Lugs Ampere Rating Description Catalog Number Wire Range List Price $ 400 For Fusible LKF4 (1) 3/0-750 kcmil (Cu or Al) 193.00 600 Switch LKF6 (2) 3/0-500 kcmil (Cu or Al) 193.00 400 For Circuit LKB4 (1) 600-750 kcmil (Cu or Al) 193.00 600 Breaker LKB6 (2) 3/0-350 kcmil (Cu or Al) 193.00 800 LKB8 (2) 600-750 kcmil (Cu or Al) 384.00 Distribution Panel Kits Ampere Number and Type of Breaker Poles Catalog Rating Voltage QP or HQ ED4 QJ2 or QJH2 FXD6 Number List Price $ Weight 120/240V; 1 Phase, 30 PQ2630 940.00 12 12 PQ2612 940.00 400 240/120V; 3 Phase, Delta 30 PQ4630 1169.00 and 240V; 3 Phase, 42 600 208Y/120V; 3 Phase, 12 12 1169.00 480Y/277V; 3 Phase, 30 PE4630 990.00 42 480V; 3 Phase, 12 6 990.00 65 120/240V; 1 Phase, 40 PQ2840 1538.00 12 16 PQ2816 1538.00 240/120V; 3 Phase, Delta 40 PQ4840 1945.00 800 240V; 3 Phase, 70 208Y/120V; 3 Phase, 12 18 PQ4818 1945.00 480V; 3 Phase, 40 PE4840 1538.00 65 12 9 PF4809 2174.00 70 39 65 8 SWITCHBOARDS Circuit Breaker Subfeed Kits: (Breakers Not Included) Description Catalog Number List Price $ For FXD6-225A 2 or 3-pole PSFFJ6 507.00 For JXD6, JD6, HJD6 400A 2 or 3-pole PSFJL6 777.00 Price includes phase and neutral load lugs and neutral link assembly. 2-pole FXD6 requires 3-pole space. Price includes branch neutral and disconnect link assembly. 1-pole breakers must not be connected to B phase. 2-pole breakers must be rated 240V. FXD6 circuit breakers are limited to 225A maximum. Price from Molded Case Circuit Breaker section. Discount Schedule A 8-9

Accessories SWITCHBOARDS 8 Description Catalog Number List Price $ Underground Pull Section or Full Height Section For Load Wiring 14.5" Deep 90" High 14" Wide (12" opening) indoor PUG14 1361.00 15" Wide (12" opening) outdoor WPUG14 2870.00 26" Wide (24" opening) indoor PUG26 1589.00 27" Wide (24" opening) outdoor WPUG26 3304.00 10" Wide (load wiring) PLW10 727.00 Lug Landing Kits (Requires Catalog Number PUG26 or WPUG26) 400A 1 Phase, or 3 Phase, PLL44 693.00 600A 1 Phase, or 3 Phase, PLL46 1040.00 800A 1 Phase, or 3 Phase, PLL48 1222.00 R Fuse Clip Adaptor Kit (Set of 3) 400A 250/600V SSRK35 96.00 600A 250/600V SSRK36 96.00 J Fuse Clip Adaptor Kit (Set of 3) 400A 250V W49814 281.00 400A 600V W49816 337.00 600A 240V W49813 391.00 600A 600V W49815 281.00 T Fuse Clip Adaptor Kit (One Pole Kit) 400A 240V TFAK52 72.00 400A 600V TFAK55 107.00 600A 240V TFAK62 85.00 600A 600V TFAK65 123.00 Optional Meter Sockets and Doors Meter Compartment Door (32" Wide x 15" High for S base socket with test block cutout (order necessary meter base from items below) PSP32 435.00 Meter Compartment Door (32" Wide x 30" High) for 2 S base meters with mounting provisions for test block and printing demand meter (order meter base from table below) Left Hand Hinge or Right Hand Hinge PSDP32 491.00 Blank Meter Compartment Door (32" Wide x 15" High) PBP32 207.00 5 Clip Meter Socket with ring PMS5 221.00 6 Clip Meter Socket with ring PMS6 250.00 8 Clip Meter Socket with ring PMS8 270.00 13 Clip Meter Socket with ring PMS13 491.00 15 Clip Meter Socket with ring PMS15 521.00 Filler Plates QP-HQP-QJ2-QJ2H-QJH2 QF3 2.10 Handle Blocking and Padlock Devices Blocking (QP-HQP 1, 2 and 3-pole) QL1 6.70 Blocking (QJ2, QJ2-H, QJH2) QJHS1 12.00 Blocking (ED2, ED4, ED6) E2HBL 14.30 Padlock (QP-HQP) QLD3 6.80 Padlock (QJ2, QJ2-H, QJH2) HL9419 13.50 Padlock (ED2, ED4, ED6) ED2HPL 14.30 Equipment Ground Bus PEGB42 86.00 A PUG26 or WPUG26 Underground pull section is required when using these lug landing kits. Discount Schedule A 8-10