The RC Circuit. Pre-lab questions. Introduction. The RC Circuit



Similar documents
RC Circuits and The Oscilloscope Physics Lab X

Lab E1: Introduction to Circuits

Electrical Resonance

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

EXPERIMENT NUMBER 8 CAPACITOR CURRENT-VOLTAGE RELATIONSHIP

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

SERIES-PARALLEL DC CIRCUITS

The Time Constant of an RC Circuit

Inductors in AC Circuits

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Lab 1: The Digital Oscilloscope

Beginners Guide to the TDS 210 and TDS 220 Oscilloscopes

Oscilloscope, Function Generator, and Voltage Division

EE 1202 Experiment #4 Capacitors, Inductors, and Transient Circuits

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

Experiment1: Introduction to laboratory equipment and basic components.

Step Response of RC Circuits

RLC Series Resonance

Using an Oscilloscope

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

Lab 3 - DC Circuits and Ohm s Law

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

Experiment 2 Diode Applications: Rectifiers

Fundamentals of Signature Analysis

Reading assignment: All students should read the Appendix about using oscilloscopes.

Ph 3504 Nuclear Magnetic Resonance and Electron Spin Resonance

AC CIRCUITS - CAPACITORS AND INDUCTORS

Lab 3 Rectifier Circuits

Reading: HH Sections , (pgs , )

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

EXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

MATERIALS. Multisim screen shots sent to TA.

Experiment 5. Strain Gage Measurements

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Lab #9: AC Steady State Analysis

= V peak 2 = 0.707V peak

Annex: VISIR Remote Laboratory

RC & RL Transient Response

INTERFERENCE OF SOUND WAVES

Measuring Impedance and Frequency Response of Guitar Pickups

Basic oscilloscope operation

Physics 42 Lab 4 Fall 2012 Cathode Ray Tube (CRT)

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Frequency Response of Filters

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Lab #4 Thevenin s Theorem

Experiment: Series and Parallel Circuits

Lecture - 4 Diode Rectifier Circuits

CHAPTER 11: Flip Flops

Transistor Amplifiers

Parallel Plate Capacitor

Electronic WorkBench tutorial

Physics 17 Lab Manual

EE101 Labs and ECEbot Assembly/Testing Instructions

Bipolar Transistor Amplifiers

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

6/2016 E&M forces-1/8 ELECTRIC AND MAGNETIC FORCES. PURPOSE: To study the deflection of a beam of electrons by electric and magnetic fields.

Step response of an RLC series circuit

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Resistance, Ohm s Law, and the Temperature of a Light Bulb Filament

ELECTRON SPIN RESONANCE Last Revised: July 2007

Laboratory 4: Feedback and Compensation

Measuring Electric Phenomena: the Ammeter and Voltmeter

Lab Exercise 1: Acoustic Waves

ECEN 1400, Introduction to Analog and Digital Electronics

Measurement of Capacitance

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

CONSTRUCTING A VARIABLE POWER SUPPLY UNIT

CIRCUITS LABORATORY EXPERIMENT 3. AC Circuit Analysis

Maximum value. resistance. 1. Connect the Current Probe to Channel 1 and the Differential Voltage Probe to Channel 2 of the interface.

Creative Inquiry Electronics Project Lab Manual. NI mydaq

Experiment #3, Ohm s Law

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

Introduction to the Smith Chart for the MSA Sam Wetterlin 10/12/09 Z +

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

Understanding Power Impedance Supply for Optimum Decoupling

Tutorial 2: Using Excel in Data Analysis

AC Direct Off-Line Power Supplies

Experiment 8: Undriven & Driven RLC Circuits

Lab Report No.1 // Diodes: A Regulated DC Power Supply Omar X. Avelar Omar de la Mora Diego I. Romero

Q1. The graph below shows how a sinusoidal alternating voltage varies with time when connected across a resistor, R.

Measuring Insulation Resistance of Capacitors

Rectifier circuits & DC power supplies

Op-Amp Simulation EE/CS 5720/6720. Read Chapter 5 in Johns & Martin before you begin this assignment.

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

PHYSICS LAB #2 Passive Low-pass and High-pass Filter Circuits and Integrator and Differentiator Circuits

Chapter 7 Direct-Current Circuits

Transcription:

The RC Circuit Pre-lab questions 1. What is the meaning of the time constant, RC? 2. Show that RC has units of time. 3. Why isn t the time constant defined to be the time it takes the capacitor to become fully charged or discharged? 4. Explain conceptually why the time constant is larger for increased resistance. 5. What does an oscilloscope measure? 6. Why can t we use a multimeter to measure the voltage in the second half of this lab? 7. Draw and label a graph that shows the voltage across a capacitor that is charging and discharging (as in this experiment). 8. Set up a data table for part one. (V, t (0-300s in 20s intervals, 360, and 420s)) Introduction The goal in this lab is to observe the time-varying voltages in several simple circuits involving a capacitor and resistor. In the first part, you will use very simple tools to measure the voltage as a function of time: a multimeter and a stopwatch. Your lab write-up will deal primarily with data taken in this part. In the second part of the lab, you will use an oscilloscope, a much more sophisticated and powerful laboratory instrument, to observe time behavior of an RC circuit on a much faster timescale. Your observations in this part will be mostly qualitative, although you will be asked to make several rough measurements using the oscilloscope. Part 1. Capacitor Discharging Through a Resistor You will measure the voltage across a capacitor as a function of time as the capacitor discharges through a resistor. The simple circuit you will use is shown in Figure 1. The capacitor, C, is an electrolytic capacitor of approximately 1000 F or 10-3 F, with a manufacturing tolerance of ±20%. The resistance of the Figure 1 resistor, R, is 100k (10 5 ohms), with a tolerance of ±5%. DMM represents the digital multimeter used to measure DC voltage across the capacitor. The idea is simple: by closing switch S, you will charge up the capacitor to approximately 10 volts using the adjustable power supply. The capacitor is connected in parallel with a resistor, so that when you open the switch the capacitor will begin discharging through the resistor. Using a stopwatch and multimeter, you will record the capacitor voltage every 20 seconds until the capacitor has almost completely discharged. The goal is to examine the exponential decay of this RC circuit. Department of Physics and Astronomy 73

Part 2. The Series RC Circuit and the Oscilloscope + - 1 2 switch R Figure 2 C o-scope We shall use the oscilloscope to study charging and discharging of a capacitor in a simple RC circuit similar to the one shown in Fig. 2. In place of the multimeter used in the first part of lab, the oscilloscope will be used to measure the voltage across the capacitor. More about the oscilloscope can be found in the Reference section at the end of this experiment. Assume the capacitor has zero charge on its plates and the switch is then put in position 1 as shown. This puts the resistor and capacitor in series with the power supply. Current flows and the capacitor charges up. How does the magnitude of the resistance affect the speed of charging? If R is small, then when the switch is initially switched to position 1, current will flow easily and the charge Q on the capacitor will build up quickly. Simultaneously, the potential difference across the capacitor increases until it equals the potential difference applied to the circuit from the power supply, V. Current will then no longer flow. If on the other hand, R is large, then a smaller current flows initially and it takes a longer time for the capacitor to charge. It can be shown theoretically that the voltage across the charging capacitor in the circuit described above is: V V e. C t / RC (1 ) This discussion is correct only for the charging of the capacitor. What happens if the switch is now moved to position 2? This takes the power supply out of the circuit. The capacitor now 74 University of North Carolina

discharges through the resistor until there is no potential difference between the plates. This is the same situation you studied in Part 1. The voltage across the discharging capacitor is given by: V V e t / RC C. The product RC is called the time constant. With the switch in position 2, VR VC. Later, at t = 1 RC, the voltage across the resistor VR V e = 0.3679V. After this time, the potential difference across the resistor has been reduced to about 37% of its initial value, V. You will observe the potential difference across the capacitor as a function of time for a circuit containing a charging and discharging capacitor. Using this data and equation above, you can estimate the value of the product RC and compare this value with the known value of RC. Why find the time constant? The time constant is a characteristic of all exponential curves and tells us, in a single number, how fast or slow the curve is rising or decaying. For any exponential function, knowing the time constant tells us how long it takes for that function to fall to 1/e, or ~37%, of its initial value for a decay; or how long it will take for a rising exponential function to reach (1 1/e), or ~63% of its final value. For example, under ideal conditions, the number of bacteria in a culture grows exponentially, and the growth can be described by an exponential equation: N(t) = Noe kt, where No is the number of bacteria initially present, N(t) is the number present some time t later, and k is the time constant, indicating how fast the culture will grow. Procedure Part 1. Capacitor Discharging Through a Resistor 1. Fully discharge your capacitor. Measure the capacitance of your capacitor using the capacitance meter provided by your instructor. Note the accuracy rating for the capacitance meter you used (see Appendix Instrument Accuracy), and use this to estimate the uncertainty of your reading. Measure also the resistance of the resistor using the multimeter, and look up the accuracy of the meter for the range you used. 2. Again, make sure the capacitor is fully discharged. Assemble the circuit shown in Fig. 1 using banana plug cables. NOTE THE CAPACITOR HAS + AND LEADS. Be sure the + end is connected to the positive (RED) connector on the power supply and the end is connected to the negative (BLACK) connector. THE CAPACITOR WILL EXPLODE IF LEFT CONNECTED BACKWARDS TO THE POWER SUPPLY. 3. Turn on the digital multimeter and set the selector switch to measure DC voltage. Locate the Data Hold button on the meter, labeled either DATA-H or DATA HOLD. When this button is pushed once, the meter display freezes to display the voltage present when the button was pushed. A DH symbol will appear in the display. Pushing the Data Hold button again releases the display to show the current circuit voltage. Department of Physics and Astronomy 75

4. Turn on the power supply with the control knob fully counterclockwise (zero). Close the switch. Turn the power supply control knob clockwise until the voltage across the capacitor and resistor is approximately 10 volts, as indicated on the multimeter. 5. When the control knob is set where you want it, measure the charged capacitor voltage. Record this value as your starting voltage, V 0, for time t = 0. 6. One lab partner should be ready to write down the voltages called out by the other partner, who will be watching a stopwatch and taking voltage readings. When you re ready to begin, simultaneously open the switch and begin timing. 7. At successive intervals of 20 seconds (20 s, 40 s, 60 s, etc.), push the Data Hold button to read the voltage. Record each voltage, V C, and time, t. Push the button again to release the display and be ready for your next reading. Continue taking readings until at least five minutes (300 seconds) have elapsed. 8. Take two additional readings at one minute intervals, e.g. at 6 minutes and 7 minutes. By now the capacitor voltage should be nearly zero. Part 2. The Series RC Circuit and the Oscilloscope In this experiment, a function (or signal) generator shown in figure 4 will replace the switch and power supply shown in figure 2. This is only a minor difference, and one that you don t need to worry too much about. In essence, the function generator has the effect of opening and closing the switch many times every second in a regular and repeatable way. This allows us to use an oscilloscope to measure the time dependence of the voltage. 1. Measure and record the resistance (R = 5.6 k, nominal value) of the resistor with the multimeter and the capacitance (C = 1 nf, nominal value) of the capacitor with the capacitance meter provided. The accuracy of the capacitance meter is listed in the Appendix. 2. Connect the function generator, capacitor, resistor, and oscilloscope O as shown in Figure 4. Connect the leads from the oscilloscope so that they are measuring the potential difference across the capacitor. Note connections for the positive and negative leads. 3. Set all the controls on the scope as instructed in the oscilloscope exercises in the Reference section to this experiment. Set the sweep rate to 50 s/div. Set the frequency on the signal generator to about 8 khz and make sure it is set to produce square waves. 76 University of North Carolina

4. Turn on the scope and the function generator. Increase the amplitude on the function generator to about half of the maximum. Adjust the gain (volts/div) and the sweep (time/div) knobs on the scope until you see a trace that looks something like Fig. 3. It may be necessary to fine-tune the trigger level setting to get a clear display. Be sure that you can see the point corresponding to t = 0. Adjust the vertical shift knob on the scope and the amplitude knob on the function generator until the maximum and minimum voltage levels of the trace are aligned with the top and bottom horizontal grid lines (graticules) on the screen. Shift the horizontal position of the trace until the beginning of the charging or discharging curve lines up with a vertical graticule. This alignment with the grid lines makes it much easier to read measurements from the scope. Have your instructor check your display before you go further. 5. Using the beginning of the decay as the t = 0 point, measure the amount of time it takes for the capacitor voltage to decay to 37% (e -1 ) of its maximum value at t = 0. Alternatively, you could measure the time it takes for the capacitor to charge to 63% of its maximum value. Either measurement gives the RC time constant for the circuit. If your scope s sweep function has a magnification switch (10x), you may be able to obtain a more precise measurement by expanding part of the trace to fill more of the screen. 6. Temporarily turn off the function generator and remove the 5600-ohm resistor from your circuit. Replace it with a resistor substitution box set to approximately 5600 ohms. Turn the function generator back on and again observe the trace on the oscilloscope. Now change the resistance value and observe how the charging/discharging curve changes. Qualitatively note what happens when you make R much larger or smaller than the original value of 5600 ohms. Be sure that you and your T.A. initial your data sheet. Analysis 1. Make a plot of ln seconds. V c V 0 vs. t from the data obtained in Part 1. Enter your time data in units of t / RC 2. The equation for the capacitor voltage as a function of time is given as VC V0e. Make a least-squares linear fit of your plot of ln V c V 0 vs. t. Identify the parameters used in the fit to the equation for the exponential decay of the capacitor voltage. Discussion For both parts of the experiment, compare the value of the time constant obtained to the predicted value, computed from the known values of R and C. Is the agreement to within the accuracy of the value for RC measured using the capacitance and multimeter? Reference: The Oscilloscope Department of Physics and Astronomy 77

The oscilloscope is such an important tool for scientists that learning how to use one is a major goal of this laboratory. Oscilloscopes provide information about the time varying voltages in a circuit. The oscilloscope works very much like a TV picture tube, where the image you see on its screen is generated by an electromagetically deflected beam of electrons fired from an electron gun located at the back of the tube. The internal circuitry of the oscilloscope itself is quite complex, but the basic operation can be understood by considering several controls. The gain (volts/div) knob increases or decreases vertical size of the trace on the screen. The number of cycles viewable on the screen (along the horizontal axis) at one time is called the sweep rate and is controlled by the sweep (sec/div) knob. The Trigger system lets you select just the right time to begin a trace on the screen, and ensures that every successive pass by the electron beam is redrawn from exactly the same spot on the waveform so that you see a stable pattern. It is helpful to think of the function generator as a switch that opens and closes very rapidly, many times per second. Each time the switch is closed, the oscilloscope triggers on the left side of its display so that what you see is the response of the circuit to the closing of the switch. This is repeated may times per second so that what you see on the screen seems to be a fixed image. This is closely related to the way televisions work. The Coupling switch (marked AC-GND-DC, beneath the Volts/Div knob) should match the type of signal being measured. Many electrical signals have both AC and DC components. Often you are interested in only the AC part of a signal - setting the coupling for AC will feed the incoming signal through a capacitor, which filters out the DC component and passes the AC component undisturbed. Setting the coupling to DC will pass all of a signal, and GND will ground the signal so that you should see only a straight line, corresponding to zero volts. Exercises: Learning to use the Tektronix 2225 and 2213 Oscilloscope 1. Obtaining a baseline trace Before turning on the scope, you should set all of the front-panel controls as follows: Set all horizontal switches to the left. (Don't confuse switches with knobs) Set all vertical switches up. Set CAL knobs to detent position (all the way clockwise, they should click into place). Set all other knobs midrange, except the Trigger VAR HOLDOFF knob, which should be set all the way counterclockwise, to the Norm position. Set Channel 1 (CH 1) Volts/Div to 2.0 V (sometimes called the 'gain') Set Sec/Div to 0.2 ms/div (this is called the 'sweep rate') Set CH1 coupling (AC-GND-DC) to AC Turn on power After a few seconds a trace should appear on the screen. Adjust intensity and focus as needed, and center the line using the horizontal and vertical POSITION knobs. 78 University of North Carolina

2. Making Measurements Set the signal generator to produce a sine wave of frequency of approximately 1kHz: turn the Function knob to its center position, the Frequency Multiplier knob to 1K and the Frequency knob to about 1, and set Attenuation to 0. Connect the signal generator to the CH1 input of the scope, turn it on and increase the power until the wave fills about half of the screen. Turn the CH1 vertical position knob to align the bottom of the wave to one of the bottom horizontal graticule lines (a graticule is any of the solid lines on the oscilloscope screen). Turn the horizontal position knob(s) until a wave peak crosses the center vertical graticule line. To measure the voltage amplitude of the sine wave, count the number of major and minor vertical divisions between the bottom and top of the wave. Multiply the number of divisions by the VOLTS/DIV readout. The result is twice the voltage amplitude. For example, if there are 3 major divisions (graticule lines) and 3 minor divisions (each tick marks a fifth of a division), then twice the amplitude is 2 volts/div times 3.6 divisions, or 7.2 volts. So amplitude equals 3.6 volts. To measure the period of the sine wave, we will take measurements from the waveform on the oscilloscope display, instead of using the frequency from the signal generator dial. Turn the horizontal position knob to line up the peak of the wave with one of the vertical graticule lines. Count the number of horizontal divisions in one wave cycle. You can adjust vertical position to make counting easier, if you like. To find the period of the wave, multiply the SEC/DIV setting by the number of divisions in one wave cycle. You can calculate the frequency from this period measurement. Now without adjusting the signal generator in any way, change the oscilloscope settings: set the volts/div to 5 volts/div, and the sweep rate to 0.5 ms/div. Again measure the potential difference and frequency of the wave. Your measurements should be the same as before: by changing oscilloscope settings you are not altering the signal you are observing, just changing the way you see it. Now try adjusting the volts/div and sweep rate by several clicks in either direction, just to see what happens. 3. Defining Zero Volts This procedure must be done for the RC circuit lab. Note: trigger mode must be AUTO for this procedure, and not NORM. Set the CH1 coupling switch to GND (this is the switch below the volts/div knob). Then adjust the position of the line on the screen using the vertical CH1 position knob: move it to a horizontal graticule. This horizontal graticule will now represent zero volts. Switch the coupling back to AC. Department of Physics and Astronomy 79

4. What to Do When a Signal is Unstable or Non-Existent Adjust the Trigger LEVEL knob. Adjust the VOLTS/DIV knob and/or the sweep rate - the trace may simply be off scale. Adjust the focus and intensity. See if you can get a baseline trace as in step 3. If you can get a trace then whatever is providing the signal may be faulty. 80 University of North Carolina