SHARP Varmepumpe. Alarmkode påp. Malfunction No. Sub category

Similar documents
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE MANUAL AE-X2M14LR MULITI SPLIT TYPE ROOM AIR CONDITIONERS (OUTDOOR UNIT) MODEL. No. S2038AEX2MLRT CONTENTS AEX2M14LR

14. Troubleshooting Guide

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

PANASONIC TROUBLE SHOOTING GUIDE

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Failure code manual. content

Haier Air conditioner

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Repair Guideline for SANYO New Erp. DC Inverter Air Conditioner (Published in May, 2013)

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

Service manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

10.1 Indoor Unit Error Display

Repair Guideline for TCL DC Inverter Air Conditioner

Repair Guideline for TCL DC Inverter Air Conditioner

SERVICE MANUAL 12KHR-N SPLIT TYPE AIR TO AIR HEAT PUMP MODEL CONTENTS 12KHR-N

Split and Multi Split air conditioners Service information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Technical service manual 2009

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

TopPage AYXP12FRN CONTENTS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

INSTALLATION MANUAL. Address card EKAC10B

Simple Self-Diagnosis by Malfunction Code

FILE NO. SVM HOW TO DIAGNOSE THE TROUBLE

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

, User s Manual

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

How To Power A Car With A Fan And A Fan (Power)

SERVICE MANUAL INDOOR UNIT

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Customized Assessment Blueprint

Technical service manual

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Room Air Conditioner SVC MANUAL(General)

MP-4000 Alarm List (Software version or later)


How To Wire Wire Wire A Power Supply On A Powerline (Powerline) From A Powerstation To A Powerplant (Powerplant) (Powerplant) (Control Board) (Wire) (Switchboard) (Wired) (

CARING FOR YOUR WATER HEATER

SERVICE MANUAL INDOOR UNIT MSZ-EF35VEW MSZ-EF22VEB - - E1 MSZ-EF25VEB E1 MSZ-EF35VEB - - E1 MSZ-EF35VEB E1 MSZ-EF35VES - E1 - E1 MSZ-EF22VEW -

TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Fault Code Check List

evo+ Installation, Service & Troubleshooting DUCTLESS SYSTEM

SERVICE MANUAL MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA INDOOR UNIT. No. OBH647. Models. Revision A: MSZ-HJ50VA- E1 has been added.


SERVICE MANUAL. Model No. HSU24VHJ(DB) Wall mounted Type DC Inverter EA-Series WARNING. Haier Group. Order No.AC1101S021V0

Split Air Conditioner

[9] TROUBLE CODE LIST

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Gas Oven Repair Guide

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Midea Commercial Air Conditioner Malfunction Handbook

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

COMPRESSOR REPLACEMENT PROCEDURE

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Air Conditioning Sign-Off Sheet

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-HJ25VA MUZ-HJ35VA OUTDOOR UNIT. No. OBH648. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

SERVICE MANUAL INDOOR UNIT

HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS

AIR CONDITIONING & HEAT PUMP SYSTEMS

*.ppt 11/2/ :48 PM 1

How To Measure Temperature On A Thermostat

Operating Instructions Air Conditioner

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SERVICE MANUAL MSZ-A18YV - E1 MSZ-A24YV - MSZ-A24YV - E1 INDOOR UNIT. No. OB345 REVISED EDITION-A. Models. Revision A : SPLIT-TYPE AIR CONDITIONERS

How To Make A High Efficiency Thermostat

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Instruction manual for Firstline FCS12000CH

LG Checkpoint-codes. Versie 2.4P-M vervangt U02.3.M

USER S MANUAL HSC-24A

6. Diagnostics for A/C System Malfunction

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Technical Information

INDEX MITSUBISHI HEAVY INDUSTRIES - PAC SERVICE MANUAL MAINTENANCE DATA 2 ERROR CODES 4 PCB INDOOR UNITS 8 ERROR DISPLAY & REMEDY CHART 12

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Instruction Manual Model: GT-SKR010B GT-SKR015B GT-SKR020B GT-SKR030B

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Transcription:

Alarmkode påp SHARP Varmepumpe Når en feilparameter blir registrert stoppes driften, 1. Slå anlegget av med fjerrkontrollen 2. Håll AUX knappen inne på innnedelen i >5Sekunder 3. LED lamper på innedelen blinker før å vise vilken kode som er registrert. ( Operation, Timer, Plasmacluster ION lamper blinker ) clock 4 + 1 2 = 5 = 2

Alarmkoder SHARP varmepumpe 4 + 1 = 5-2 = 2 Før komplett liste alarmkoder se, servicemanual

Malfunction diagnosis indications, descriptions, inspection methods and remedies : Flashes in 2-sec intervals(normal) in operation Normal flashing 1time :On :Off :Flashes3timesin0.2-secintervals by operation lamp on indoor 0 1 short-circuit - Normal Heat exchanger shortcircuit Outdoor temperature short circuit Suction short circuit Inspection location/method (1) Measure resistance of the. (2) Check the lead wire of the for torn sheath and short-circuit. (3) No abnormality found in above inspections(1)and(2). Remedy (1) Replace the (2) Replace the (3) Replace the control [9] CHART -3 2Way valve thermitor short circuit. 3 14 2time 2 Cycle temperature Compressor high temperature (1) Check the air outlet for blockage. (2)Checkifthepowersupplyvoltageis216 Vorhigheratfullpower. (3) Check the pipe connections for refrigerant leaks. (4) Measure resistance of the compressor. (TH1:Approx.53k½at25¼C) (5) Check the expansion valve for proper operation. (1) Ensure unobstructed air flow from the air outlet. (2) Connect power supply of proper voltage. (3) Charge the specified amount of refrigerant. (4) Replace the compressor (5) Replace the expansion valve coil, expansion valve or control Indoor in operation in temporary stop -3 to compressor discharge overheat*3 to heat exchanger overheat *3 to indoor heat exchanger overheat *3-4 toipmoverheat*3 (Temporary stop for parts protection) -5 IPM high temperature (1) Measure resistance of the heat sink. (1) Replace the heat sink. 3time 3 Dry operation Temporary stop due to dehumidifying operation*3 *3: The content of diagnosis is transferred to the indoor via serial communication, but it does not trigger a complete operation. Number of repetition : No complete

: Flashes in 2-sec intervals(normal) : On : Off : Flashes 3 times in 0.2-sec intervals 5time by operation lamp on indoor 5-4 - short-circuit Heat exchanger opencircuit Outdoor temperature open circuit Suction open-circuit Discharge open circuit Inspection location/method (1) Check the connector of the for secure installation. (2) Measure resistance of the. (3) Check the lead wire of the. Remedy (2) Replace the (3) Replace the (4) Replace the control 3 15 6time 6 DC DC overcurrent (1) IPM continuity check (2) Check the IPM and heat sink for secure installation. (3) Check the fan motor for proper rotation. (5) No abnormality found in above inspections(1) through(4). (1) Replace the control (2) Correct the installation (tighten the screws). Apply silicon grease. (3) Replace the fan motor. (4) Replace the control (5) Replace the compressor. 7time 7 AC AC overcurrent AC overcurrent AC maximum current (1)ChecktheIPMisattachedcorrectlyto the control PWB. (1) Check the air outlet for blockage. (2) Check the fan for proper rotation. (1) Check the air outlet for blockage. (2) Check the fan for proper rotation. (1) Replace the control (1) Ensure unobstructed air flow from the air outlet. (2) Check the fan motor. (1) IPM continuity check (1) Replace the control PWB (1) Ensure unobstructed air flow from the air outlet. (2) Check the fan motor. -3 AC current deficiency (1) Check if there is an open-circuit in the secondary winding of the current transformer of the control PWB. (2) Check if the refrigerant volume is abnormally low. (3) Check if the refrigerant flows properly. (1) Replace the control (2) Charge the specified amount of refrigerant. (3) Correct refrigerant clogs.(2-way valve, 3-way valve, pipe, expansion valve) *3: The content of diagnosis is transferred to the indoor via serial communication, but it does not trigger a complete operation. Number of repetition : No complete

: Flashes in 2-sec intervals(normal) : On : Off : Flashes 3 times in 0.2-sec intervals by operation lamp on indoor - Inspection location/method Remedy in compleate 9time cooling/heating switchover Thermistor installtion or 4-way valve (1)Checkto makesure TH2(heat exchanger) and TH5 (2-way valve) are installed in correct posittions. (2) Measure resistance of TH1 and TH5. (2) Replace the (3)Checkthe4-wayvalveforproper operation. (4) No abnormality found in above inspections (1) (3) Replace the 4-way valve. (4) Replace the control PWB -3 Torque control (1) Check if the refrigerant volume is abnormally low. (2)Checkthe4-wayvalveforproper operation. (1) Change the speccified amount of refrigerant. (2) Replace the 4-way valve. (3) Check to see compressor type is correct (3) Replace the compressor with correct. 3 16 in compleate 10 time 10-4 Gas leak EEPROM EEPROM() EEPROM() data (1)Checktomakesure TH2(heatexchange) or indoor thermitor TH2(Heat exchange) is installed in correct poctions. (2) Check if the refrigerant volume is abnomally low. (2) Change the speccified amount of refrigerant. (1) Replace the control PWB 11 time 11 DC fan DC fan rotation. (1)ChecktheconnectorCN3ofthe DC fan motor for secure installation. (2) Check DC fan motor for proper rotation. (3) Check fuse FU3. (4) control PCB. (2) Replace the fan motor. (3) Replace the control PCB (4) Replace the control PCB 12 time 12 Outdoor terminal bord fuse. Outdoor terminal bordfuseopen. (1) Check the connector CN10 for secure installation. (2) Check the fuse open of terminal board. (2) Replace the terminal board. *3: The content of diagnosis is transferred to the indoor via serial communication, but it does not trigger a complete operation. Number of repetition : No complete

3 17 : Flashes in 2-sec intervals(normal) : On : Off : Flashes 3 times in 0.2-sec intervals Indoor in operation in temporary stop Indoor in operation in temporary stop by operation lamp on indoor 13 time 13 14 time 14 17 18-3 - Inspection location/method Remedy DC compressor PAM Wires between s Wires between s Compressor start up Compressor rotation (120 energing ) Compressor rotation (180 energing ) Inverter current detection circuit PAM over voltage Compressor rotation. PAM clock Serial open circuit does notturnondueto erroneous wiring Serial short circuit Erroneous serial wiring (1) Check the colors (red, white, orange) of the compressor cords for proper connection.(pwb side, compressor side) (2) Check if the IPM terminal resistance values are uniform. (3) No abnormality found in above inspections(1)and(2). (1) Check the AC power supply voltage for fluctuation. (2) No abnormality found in above inspection (1) Check the wires between s. (2) Check voltage between Nos. 1 and 2 on the terminal boards. (1) Check the wires between s. (2) Check the fuse. (3)Check15-V,13-Vand5-Vvoltageson the PWB. Check resistance between IPM terminals. (4)CheckpinsNo.5and7ofconnectorCN3of the fan motor for short-circuit. (5) control PWB (1) Check the wires between s. (U:Red,V:White,W:Orange) (2) Replace the control (3) Replace the control (4) Replace the compressor. (1) Check inverter current detection circuit. (1) Replace the control PWB (1) Connect the connector. (2) Replace the active filter. (1) Check the PAM clock for proper input. (1) Replace th control PWB (1) Connect stable power supply. (2) Replace the control (1) Correct the wiring. (2) Replace the fuse or control (3) Replace the control (4) Replace the fan motor. (5) Replace the control (1) Correct the wiring. (1) Check the wires between s. (1) Correct the wiring. 19 20 Indoor fan Indoor control PWB Indoor fan EEPROM data (1) Checktheindoorfanmotorforproper rotating operation.(check for fan lock.) (2)Checktheleadwireoftheindoorfan motor for open-circuit. (3) Check CN1 of the indoor fan motor for secure installation. (1) Error in data read from the indoor EEPROM (1) Replace the indoor fan motor. (2) Replace the indoor fan motor. (3) Correct the installation of CN1 of the indoor fan motor. (4) Replace the indoor control PWB. (1) Replace the indoor control PCB. *3: The content of diagnosis is transferred to the indoor via serial communication, but it does not trigger a complete operation. Number of repetition : No complete