LG Checkpoint-codes. Versie 2.4P-M vervangt U02.3.M
|
|
- Richard Gervase Baldwin
- 8 years ago
- Views:
Transcription
1 LG LG Checkpoint-s Versie 2.4P-M vervangt U02.3.M BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THE SERVICEMANUAL. ONLY FOR AUTHORIZED SERVICE PERSONNEL. 1
2 Hoofdstukindeling Single A (vloer- & plafond UV / cassette UT / kanaal UB) Aan / Uit - Inverter UU..(W) - Variabel (aan/uit)...26 AT-C.. / AT-H.. / LB-C.. / LB-D.. / LB-G.. / LB-H.. / LT-B.. / LT-C.. / LT-D.. / LT-E.. / LV-B.. / P..AH Multi-split Inverter FM..AH - Variabel (aan/uit)...92 M..AC/AH 2
3 - Multi-split tot A2-C.. / A3-C.. / A2-H.. / A3-H.. / LM.. RAC Standaard wandunit (aan/uit)...97 LS-J.. / LS-K.. / LS-L.. / S..ACL / S..ACP / S..AH(P) / G..AH - ART COOL Deluxe / Panel (aan/uit)...97 LS-P.. / A09AH* / -12- / -18- / C07AH* / -09- / Standaard wandunit Inverter...99 LS-N.. / LS-Q.. / LS-R.. / S..AN / S..AW - ART COOL Deluxe Inverter C09AW* / C12AW* - ART COOL Deluxe Inverter C18AW* / C24AW* -ART COOL Panel Inverter A09AW* / A12AW* / A09AW1 / A12AW1 3
4 LG Single A (vloer- & plafond UV / cassette UT / UB kanaal) UU..(W) Inverter 1-fase (single-split) Inverter 3-fase (Single-split) Synchro (master/slave) Variabel (aan/uit, single-split) 4
5 6.6 Check Trouble shooting CH01, CH02, CH06 5. Trouble Shooting Title Cause of error Check point & rmal condition 01 Indoor air sensor Connector connection error Faulty PCB Faulty sensor (Open / Short) rmal resistor : 10KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C(Plugged) Refer to sensor resistance table. 02 Indoor inlet pipe sensor Connector connection error Faulty PCB Faulty sensor (Open / Short) rmal resistor : 5KΩ/ at 25 C(Unplugged) rmal voltage : 2.5Vdc / at 25 C(Plugged) Refer to sensor resistance table. 06 Indoor outlet pipe sensor Connector connection error Faulty PCB Faulty sensor (Open / Short) rmal resistor : 5KΩ/ at 25 C(Unplugged) rmal voltage : 2.5Vdc / at 25 C(Plugged) Refer to sensor resistance table. Check Flow Chart Unplug the sensor on Indoor unit PCB Estimate the Voltage of each sensor. Check the Connector connection Is the voltage of the sensor 2.5Vdc at 25 C Correct connection Is it normal? Correct connection Repair or Change the PCB. Unplugged Plugged Estimate the resistance of each sensor. Is the resistance of the sensor 10Ω / 5kΩ at 25 C? Correct connection 10kΩ Ω 2.5Vdc V Plug the sensor on Indoor unit PCB Check the resistance Check the voltage 5
6 5. Trouble Shooting 6.7 Check Trouble shooting CH03 Title Cause of error Check point & rmal condition 03 Communication Error (Wired remote controller) Connector connection error Faulty PCB / Remote controller Connection wire break Connection of wire Main PCB Volt. DC12V ise interference Check Flow Chart Check the wire connection(open / Short / Miswirring) CN-REMO Is it normal? Correct connection Or change connection wire Is the soldering state of connector is normal? Check the volt. of main PCB power source. (DC 12V,DC 5V) Re-soldering component Or change the PCB Wired R/C S 12V GND (YL) (RD) (BR) Indoor Unit 12V S GND (RD) (YL) (BR) Is it normal? Check the installation of wired remote controller. (ise interference) Correct connection Or change the PCB 12Vdc V 12Vdc V Is it normal? Adjust the state of installation Check the Volt. Check the Volt. Copyright 2008 LG Electronics. Inc. All right reserved
7 6.8 Check Trouble shooting CH04 5. Trouble Shooting 04 Title Cause of error Check point & rmal condition Drain pump / Float switch Float switch open. (rmal : short) Water over flow The connection of wire (Drain pump/ Float switch) Drain pump power input. (220V) Drain tube installation. Indoor unit installation. (Inclination) Check Flow Chart Check the level of water (Float moves top position) Is it normal? Check Drain Pump CN-Float CN-Float Is the float switch clean? Clean float switch Drain pump check Check the wire connection (Open, Soldered poorly) Is it normal? Is the resistance of f loat switch normal (short)? Correct connection Or re-soldering PCB Change the float switch Check the wire connection (Open, Soldered poorly) Is it normal? Is the resistance of Drain Pump? rmal ( about 400Ω )? Correct connection Or re-soldering PCB Change the Drain Pump Is the drain pump clean? Clean drain pump Check drain tube installation Copyright 2008 LG Electronics. Inc. All right reserved
8 5. Trouble Shooting 6.9 Check Trouble shooting CH09, CH10 Title Cause of error Check point & rmal condition 09 EEPROM Check sum (Indoor) Check sum error Check the poor soldering. Change PCB 10 BLDC motor fan lock (Indoor) Fan motor break down Fan motor & PCB poor contact Obstruction to the fan Check the indoor fan motor. Check the connection status between PCB and fan motor. Check Flow Chart Check the indoor fan motor. (Fan is locked by obstruction) Is it normal? Remove obstruction Check the connection status between PCB and fan motor Is it normal? Correct connection Or re-soldering PCB Check the DC Motor signal Is it normal? Change Indoor Motor Copyright 2008 LG Electronics. Inc. All right reserved
9 6.10 Check Trouble shooting CH05, CH53 5. Trouble Shooting 05 / 53 Title Cause of error Check point & rmal condition Communication (Indoor Outdoor) The connector for transmission is disconnected. The connecting wires are misconnected. The communication line is break Outdoor PCB is abnormal. Indoor PCB is abnormal. Check power input AC 230V. (Outdoor, Indoor) Check connector for transmission Check wires are misconnecting. Check transmission circuit of outdoor PCB Check transmission circuit of indoor PCB Check Flow Chart Check the input power AC230V (Outdoor, Indoor unit) Is the connection of GND,GND1,GND2, correctly connected? Correct connection Is it normal? ( 230V ±10% ) Needs electric work Change PCB Check the communication wires are correctly connected. Is it normal? Check the resistance between communication line and GND. (rmal : Over 2MΩ) Adjust the connection of wire Confirm the wire of "Live", "Neutral", "Signal" Is it normal? Is connector for communication correctly connected? Correct connection CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit. Copyright 2008 LG Electronics. Inc. All right reserved
10 5. Trouble Shooting 6.11 Check Trouble shooting CH21 Title Cause of error Check point & rmal condition 21 DC Peak Instant over current Over Rated current Poor insulation of IPM An instant over current in the U,V,W phase - Comp lock - The abnormal connection of U,V,W Over load condition - Overcharging of refrigerant - Pipe length. Poor insulation of compressor Check Flow Chart Check the wire connection.(u,v,w) Is it normal? (1 Ph : 230V ±10% 3 Ph : 400V ±10% ) Needs electric work Is it normal? Check the resistance of comp. ( difference at each terminal) Is it normal? Check the electricity leakageof the compressor. (Refer to comp check table) Correct connection Change Compressor Check DC link capacitor Is it normal? (Refer to belows) Check Over load condition - Overcharging of refrigerant - Pipe Length - Condenser is blocked - Outdoor fan is locked Change Main PCB Change DC link capacitor Or Main PCB Remove obstruction Change outdoor fan or motor Change refrigerant Is it normal? Check the input power (Outdoor, Indoor unit) Change Compressor Dc link voltage table DC Link Voltage Model Type n operating Operating 1 Phase AUUW126C PSC DC300V 10% DC280V 10% AUUW186C PSC DC300V 10% DC280V 10% AUUW246D PFC DC300V 10% DC380V 10% AUUW306D PFC DC300V 10% DC380V 10% AUUW366D PFC DC300V 10% DC380V 10% AUUW426D PFC DC300V 10% DC380V 10% AUUW486D PFC DC300V 10% DC380V 10% AUUW606D PFC DC300V 10% DC380V 10% 3 Phase AUUW368D PSC DC540V 10% DC500V 10% AUUW428D PFC DC540V 10% DC680V 10% AUUW488D PFC DC540V 10% DC680V 10% AUUW608D PFC DC540V 10% DC680V 10% Copyright 2008 LG Electronics. Inc. All right reserved
11 5. Trouble Shooting 6.12 Check Trouble shooting CH22 Title Cause of error Check point & rmal condition 22 Max. C/T Over current Malfunction of compressor Blocking of pipe Low voltage input Refrigerant, pipe length, blocked, Check Flow Chart Check the wire connection.(u,v,w) Is it normal? (1 Ph : 230V ±10% 3 Ph : 400V ±10% ) Needs electric work Is it normal? Check the resistance of comp. ( difference at each terminal) Is it normal? Check the electricity leakageof the compressor. (Refer to comp check table) Correct connection Change Compressor Check DC link capacitor Is it normal? (Refer to belows) Check Over load condition - Overcharging of refrigerant - Pipe Length - Condenser is blocked - Outdoor fan is locked Change Main PCB Change DC link capacitor Or Main PCB Remove obstruction Change outdoor fan or motor Change refrigerant Is it normal? Check the input power (Outdoor, Indoor unit) Change Compressor Dc link voltage table DC Link Voltage Model Type n operating Operating 1 Phase AUUW126C PSC DC300V 10% DC280V 10% AUUW186C PSC DC300V 10% DC280V 10% AUUW246D PFC DC300V 10% DC380V 10% AUUW306D PFC DC300V 10% DC380V 10% AUUW366D PFC DC300V 10% DC380V 10% AUUW426D PFC DC300V 10% DC380V 10% AUUW486D PFC DC300V 10% DC380V 10% AUUW606D PFC DC300V 10% DC380V 10% 3 Phase AUUW368D PSC DC540V 10% DC500V 10% AUUW428D PFC DC540V 10% DC680V 10% AUUW488D PFC DC540V 10% DC680V 10% AUUW608D PFC DC540V 10% DC680V 10% Copyright 2008 LG Electronics. Inc. All right reserved
12 5. Trouble Shooting 6.13 Check Trouble shooting CH40 Title Cause of error Check point & rmal condition 40 C/T Internal circuit Initial current error Malfunction of current detection circuit. (Open / Short) The voltage of C01N Is 4.0Vdc (25A). Check Flow Chart Check the input power AC230V (Outdoor, Indoor unit) Is it normal? ( 230V±10%) Correct connection TRANS Check C01N Is it normal (4.0Vdc )? Change Main PCB C01N Check Check TRANS Is it normal? Change TRANS Change main PCB V Copyright 2008 LG Electronics. Inc. All right reserved
13 6.14 Check Trouble shooting CH23, CH28 5. Trouble Shooting 23 Title Cause of error Check point & rmal condition DC Link Low voltage. 1ph : DC link volt. is 140Vdc. 3ph : DC link volt. is 250Vdc. Check the power source. Check the components. 28 DC Link High voltage 1ph : DC link volt. is 140Vdc. 3ph : DC link volt. is 250Vdc. Check the power source. Check the components. 25 Input voltage Abnormal Input voltage (140Vac, 300Vac ) Check the power source. Check the components. Check Flow Chart Check DC link voltage Check the wire connection.(u,v,w) V Is it normal? Correct connection Check TRANS1 Is it normal? Is it normal? Check the input power Change Compressor Change Compressor Dc link voltage table CN_TRANS 1 DC Link Voltage Model Type n operating Operating 1 Phase AUUW126C PSC DC300V 10% DC280V 10% AUUW186C PSC DC300V 10% DC280V 10% AUUW246D PFC DC300V 10% DC380V 10% AUUW306D PFC DC300V 10% DC380V 10% AUUW366D PFC DC300V 10% DC380V 10% AUUW426D PFC DC300V 10% DC380V 10% AUUW486D PFC DC300V 10% DC380V 10% AUUW606D PFC DC300V 10% DC380V 10% 3 Phase AUUW368D PSC DC540V 10% DC500V 10% AUUW428D PFC DC540V 10% DC680V 10% AUUW488D PFC DC540V 10% DC680V 10% AUUW608D PFC DC540V 10% DC680V 10% Copyright 2008 LG Electronics. Inc. All right reserved
14 5. Trouble Shooting 6.15 Check Trouble shooting CH24 Title Cause of error Check point & rmal condition 24 Press S/W Open Low / High press S/W open. Check the connection of CN_PRESS Check the SVC V/V open. Check the leakage of refrigerant. Check Flow Chart Is the wire connection normal? Is the soldering state of connector is normal? Is the SVC Valve opened? Check the leakage of refrigerant. Check Pressure of suction pipe Check Pressure of discharge pipe Correct connection Re-soldering component Open SVC Valve Pressure switch table Switch Low pressure switch High pressure switch Spec 0.03 Mpa 4.3 Mpa Model AUUW126C AUUW246D AUUW186C AUUW306D AUUW366D AUUW426D AUUW486D AUUW606D AUUW368D AUUW428D AUUW488D AUUW608D CN_PRESS Is it normal? Change main PCB Re-vaccuming system & Re-charging Copyright 2008 LG Electronics. Inc. All right reserved
15 5. Trouble Shooting 6.16 Check Trouble shooting CH26, CH27 Title Cause of error Check point & rmal condition 26 DC Compressor Position Compressor position detect error Check the connection of comp wire U,V,W Malfunction of compressor Check the component of IPM, detection parts. 27 PSC Fault PFC Fault Over current at IGBT /PFC module Check the component of IGBT /PFC module. Check the components. Check Flow Chart Check the wire connection.(u,v,w) Is it normal? (1 Ph : 230V ±10% 3 Ph : 400V ±10% ) Needs electric work Is it normal? Check the resistance of comp. ( difference at each terminal) Is it normal? Check the electricity leakageof the compressor. (Refer to comp check table) Correct connection Change Compressor Check DC link capacitor Is it normal? (Refer to belows) Check Over load condition - Overcharging of refrigerant - Pipe Length - Condenser is blocked - Outdoor fan is locked Change Main PCB Change DC link capacitor Or Main PCB Remove obstruction Change outdoor fan or motor Change refrigerant Is it normal? Check the input power (Outdoor, Indoor unit) Change Compressor Dc link voltage table DC Link Voltage Model Type n operating Operating 1 Phase AUUW126C PSC DC300V 10% DC280V 10% AUUW186C PSC DC300V 10% DC280V 10% AUUW246D PFC DC300V 10% DC380V 10% AUUW306D PFC DC300V 10% DC380V 10% AUUW366D PFC DC300V 10% DC380V 10% AUUW426D PFC DC300V 10% DC380V 10% AUUW486D PFC DC300V 10% DC380V 10% AUUW606D PFC DC300V 10% DC380V 10% 3 Phase AUUW368D PSC DC540V 10% DC500V 10% AUUW428D PFC DC540V 10% DC680V 10% AUUW488D PFC DC540V 10% DC680V 10% AUUW608D PFC DC540V 10% DC680V 10% Copyright 2008 LG Electronics. Inc. All right reserved
16 4. Trouble Shooting 29 Title Cause of error Check point & rmal condition Inverter compressor over current Inverter compressor input current is over 30A 1. Overload operation (Pipe clogging/covering/eev defect/ref. overcharge) 2. Compressor damage(insulation damage/motor damage) 3. Input voltage low 4. ODU inverter PCB assembly damage Error Diagnosis and Countermeasure Flow Chart Is installation condition normal? Are the resistance Between each phase and insulation resistance of Inverter compressor normal? Is compressor Wire connection condition normal? 1. Check Pipe clogging/distortion 2. Check Covering (Indoor/Outdoor Unit) 3. Check EEV connector assemble condition/normal operation 4. Check refrigerant pressure Reassemble or manage if abnormality found 1. Check resistance between each terminal of compressor (0.188 ±7%) 2. Check insulation resistance between compressor terminal and pipe (over 50MΩ ) Replace compressor if abnormality found 1. Check inverter PCB assembly U,V,W connector connection condition 2. Check wire disconnection and wiring 3. Check compressor terminal connection condition (bad contact) Reassemble if abnormality found Is input voltage normal? Check L~N phase is 220V ±15% Check connection condition and wiring if power is abnormal Is inverter PCB assembly normal? Check inverter PCB assembly IPM normality Replace inverter PCB assembly Recheck power and installation condition Copyright 2007 LG Electronics. Inc. All right reserved
17 5. Trouble Shooting 6.17 Check Trouble shooting CH32, CH33 32 Title Cause of error Check point & rmal condition D-pipe (Inverter) temp. high (105 C ) Discharge sensor (Inverter) temp. high Check the discharge pipe sensor for INV. Check the install condition for over load. Check the leakage of refrigerant. Check the SVC V/V open. Refer to sensor resistance table. 33 D-pipe (Constant) temp. high (105 C ) Discharge sensor (Cons.) temp. high Check the discharge pipe sensor for Cons. Check the install condition for over load. Check the leakage of refrigerant. Check the SVC V/V open. Refer to sensor resistance table. Check Flow Chart Check Over load condition - Refrigerant leakage - Condenser is blocked - Outdoor fan is locked Unplug the sensor on Outdoor unit PCB Remove obstruction Change outdoor fan or motor Change refrigerant Is the resistance of the sensor is 200kΩ at 25 C? Plug the sensor on Indoor unit PCB Change the sensor Check the Connector connection Estimate the Voltage of each sensor. Is it normal? Correct connection Is the voltage of the sensor is 4.5Vdc at 25 C Change the sensor Estimate the resistance of each sensor. Repair or Change the PCB. Copyright 2008 LG Electronics. Inc. All right reserved
18 4. Trouble Shooting Title Cause of error Check point & rmal condition 39 Transmission Error Between (PFC Micom INV Micom) Communication Error Between PFC Micom and INV Micom. 1. Micom defect/circuit defect 2. Different Micom S/W Version 3. ODU inverter PCB assembly damage Error Diagnosis and Countermeasure Flow Chart Is PFC Micom & INV Micom S/W Program normal? Upgrade Micom Program Is Inverter PCB assembly normal? Replace inverter PCB assembly Recheck power and installation condition Copyright 2007 LG Electronics. Inc. All right reserved
19 5. Trouble Shooting 6.18 Check Trouble shooting CH41, CH44, CH45, CH46, CH47, CH65 Title Cause of error Check point & rmal condition D-pipe sensor(inv) D-pipe sensor(cons) Connector connection error Faulty PCB Faulty sensor (Open / Short) rmal resistor : 200KΩ/ at 25 C (Unplugged) rmal voltage : 4.5Vdc / at 25 C (plugged) Refer to sensor resistance table. 44 Air sensor Connector connection error Faulty PCB Faulty sensor (Open / Short) rmal resistor : 10KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) Refer to sensor resistance table Condenser Pipe sensor Suction Pipe sensor Connector connection error Faulty PCB Faulty sensor (Open / Short) rmal resistor : 5KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) Refer to sensor resistance table. 65 Heat sink sensor Connector connection error Faulty PCB Faulty sensor (Open / Short) rmal resistor : 5KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) Refer to sensor resistance table. Check Flow Chart Unplug the sensor on Indoor unit PCB Estimate the Voltage of each sensor. Check the Connector connection Is the voltage of the sensor is 4.5Vdc / 2.5Vdc at 25 C Change the sensor Is it normal? Correct connection Repair or Change the PCB. Unplugged Plugged Estimate the resistance of each sensor. Is the resistance of the Sensor is 200kΩ/10kΩ /5kΩ at 25 C? Change the sensor 10kΩ 2.5Vdc Ω V Plug the sensor on Indoor unit PCB Check the resistance Check the voltage Copyright 2008 LG Electronics. Inc. All right reserved
20 5. Trouble Shooting 6.19 Check Trouble shooting CH51, CH60 Title Cause of error Check point & rmal condition 51 Over capacity Over capacity Combination Check the indoor unit capacity. Check the combination table. 60 EEPROM Check sum Check sum error Check the connection port. Check the poor soldering. Check Flow Chart (CH51) Check the indoor unit combination Check the outdoor unit max combination Is it normal? Check PCB Correct connection Check Flow Chart (CH60) Check the the connection port. Is it normal? Correct connection Change EEPROM Copyright 2008 LG Electronics. Inc. All right reserved
21 Single A: Inverter & Synchro (UU..W & UU72 / 100) Title Cause of error 52 Transmission error between (Inverter PCB Main PCB) Main controller of Master unit of Master unit can t receive signal from inverter controller 4. Trouble Shooting Check point & rmal condition 1. Power cable or transmission cable is not connected 2. Defect of outdoor Main fuse/ise Filter 3. Defect of outdoor Main / inverter PCB Error diagnosis and countermeasure flow chart Is transmission LED (Yellow) of inverter compressor PCB on? Is noise filter or fuse normal? Replace noise filter or fuse Replace inverter compressor PCB Is transmission cable connected correctly? Re-connect transmission cable Is MAIN PCB normal? Replace MAIN PCB Replace inverter compressor PCB Check Point - Check the Transmission connector and LED (Main & Inverter) 48/56k <Inverter PCB> Copyright 2007 LG Electronics. Inc. All right reserved. <MAIN PCB>
22 Troubleshooting Guide 14) Troubleshooting CH54 Title Cause of error Check point & rmal condition 54 3-phase wrong wiring of main outdoor unit 3-phase wrong wiring of outdoor unit (Reverse Phase /omission of phase) Abnormal Main PCB connection of CN_Phase Changed R, S, T connection order Check Point 1. Check the connection condition of R,S,T wire. 2. Check the connection condition of CN_Phase. 3. Check the outdoor main fuse. 22
23 6.20 Check Trouble shooting CH61, CH62 5. Trouble Shooting Title Cause of error Check point & rmal condition 61 Condenser pipe sensor temp. high condenser pipe sensordetected high temp.(65 C) Check the load condition. Check the sensor of Condenser pipe sensor. rmal resistor : 5KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (Plugged) 62 Heat sink sensor temp. high heat sink sensor detected high temp. (85 C) Check the load condition. Check the sensor of heat sink. rmal resistor : 10KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (Plugged) Check Flow Chart Check Over load condition - Refrigerant leakage - Condenser is blocked - Outdoor fan is locked Unplug the sensor on Outdoor unit PCB Remove obstruction Change outdoor fan or motor Change refrigerant Is the resistance of the Sensor is 5kΩ /10kΩ at 25 C? Plug the sensor on Indoor unit PCB Change the sensor Check the Connector connection Estimate the Voltage of each sensor. Is it normal? Correct connection Is the voltage of the sensor is 4.5Vdc / 2.5Vdc at 25 C Change the sensor Estimate the resistance of each sensor. Repair or Change the PCB. Copyright 2008 LG Electronics. Inc. All right reserved
24 4. Trouble Shooting 73 Title Cause of error Check point & rmal condition AC input instant over current error (Matter of software) Inverter PCB input power current is over 48A(peak) for 2ms 1. Overload operation (Pipe clogging/covering/eev defect/ref.overcharge) 2. Compressor damage (Insulation damage/motor damage) 3. Input voltage abnormal (L, N) 4. Power line assemble condition abnormal 5. Inverter PCB assembly damage (input current sensing part) Error Diagnosis and Countermeasure Flow Chart Is installation condition normal? 1.Check Pipe clogging/distortion 2.Check Covering (Indoor/Outdoor Unit) 3.Check EEV connector assemble condition/normal operation 4.Check refrigerant pressure Reassemble or manage if abnormality found Is input voltage normal? Check L~N phase voltage is 220V ± 10% Check connection condition and wiring if power is abnormal Is AC input Wire connection condition normal? 1.Check L,N connection condition 2.Check wire disconnection and wiring Reassemble if abnormality found Is compressor Wire connection condition normal? 1.Check inverter PCB assembly U,V,W connector connection condition 2.Check wire disconnection and wiring 3.Check compressor terminal connection condition(bad contact) Reassemble if abnormality found Is inverter PCB assembly normal? Check inverter PCB assembly IPM normality Replace inverter PCB assembly Recheck power and installation condition Copyright 2007 LG Electronics. Inc. All right reserved
25 Troubleshooting Guide 16) Troubleshooting CH67, CH105 Title Cause of error Check point & rmal condition 67 Outdoor fan lock Outdoor fan is not operating Check the fan condition. Check the fan connector 105 Communication error between main PCB and fan PCB Communication error between main PCB and fan PCB Short or fusing of communication line Poor outdoor unit PCB Power input when the DC link capacitor discharges Check Point CH Check the install condition for fan. CH Is communication line between the main PCB and the fan PCB normal? 2. Is the communication LED on? 25
26 Single A Aan / uit, Single-split AT-C.. / AT-H.. LB-C.. / LB-D.. / LB-E.. / LB-G.. / LB-H.. LT-B.. / LT-C.. / LT-D.. / LT-E.. LV-B.. P03AH / P05AH / P08AH 26
27 Troubleshooting Guide 1) Troubleshooting CH01, CH02, CH06 Title Cause of error Check point & rmal condition 01 Indoor air sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 10K. / at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 02 Indoor inlet pipe sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 5K. / at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 06 Indoor outlet pipe sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 5K. / at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 10k. 2.5Vdc. V Check the resistance Check the voltage Check Point 1. Unplug the sensor on Indoor unit PCB. 2. Estimate the resistance of each sensor. 3. If the resistance of the sensor is 10K. / 5K. at 25 C, then sensor is normal. 4. If the resistance of the sensor is 0 K. or 8, then sensor is abnormal. Change the sensor. 5. Plug the sensor on Indoor unit PCB and Power ON. 6. Estimate the voltage of each sensor. 7. If the voltage of the sensor is 2.5Vdc at 25 C, then sensor is normal. 8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. Repair or Change the PCB. 27
28 Troubleshooting Guide 2) Troubleshooting CH03 03 Title Cause of error Check point & rmal condition Communication Wired R/C Open / Short Wrong connection Connection of wire Main PCB Volt. DC12V ise interference Wired R/C 12V S GND Indoor Unit 12V S GND CN-REMO 12Vdc 12Vdc V V Check the Volt. Check the Volt. Check Point 1. Check the wire connection. (Open / Short) Repair the connection 2. Check the soldering state of connector. (Soldered poorly) Repair or Change the PCB. 3. Check the volt. Of main PCB power source. (DC 12V, DC 5V) Repair or Change the main PCB. 4. Check the installation of wired remote controller. (ise interference) Adjust the state of installation 28
29 Troubleshooting Guide 3) Troubleshooting CH04 04 Title Cause of error Check point & rmal condition Drain pump / Float switch Float switch Open. (rmal : short) The connection of wire(drain pump/ Float switch) Drain pump power input. (220V) Drain tube installation. Indoor unit installation. (Inclination) CN Float 0. CN-Float CN-D/PUMP. Check the resistance Check Point 1. Check the wire connection. (Open, Soldered poorly) Repair the connection or change the PCB. 2. Check the resistance of float switch (Abnormal : Open, rmal : short) Check the float switch. 3. Check the level of water 4. Check the volt. Of Drain pump power supply. (AC 230V) Repair or Change the main PCB. 29
30 Troubleshooting Guide 4) Troubleshooting CH05, CH53 05 / 53 Title Cause of error Check point & rmal condition Communication (Indoor Outdoor) Communication poorly Power input AC 220V. (Outdoor, Indoor) The connector for transmission is disconnected. The connecting wires are misconnected. The GND1,2 is not connected at main GND. The communication line is shorted at GND. Transmission circuit of outdoor PCB is abnormal. Transmission circuit of indoor PCB is abnormal. Check Point 1. Check the input power AC230V. (Outdoor, Indoor unit) 2. Check the communication wires are correctly connected. Adjust the connection of wire Confirm the wire of Live, Neutral 3. Check the resistance between communication line and GND. (rmal : Over 2M. ) 4. Check the connector for communication is correctly connected. 5. Check the connection of GND1, GND2, and main GND. 6. If one indoor unit is operated normally, outdoor PCB is no problem. Check the another indoor unit. * CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit. 30
31 Troubleshooting Guide 5) Troubleshooting CH21 21 DC Peak Title Cause of error Check point & rmal condition Instant over current Over Rated current Poor insulation of IPM An instant over current in the U,V,W phase - Comp lock - The abnormal connection of U,V,W Over load condition - Overcharging of refrigerant - Pipe length. Poor insulation of compressor Comp U Resistance(. ) at 20 C V W. Terminal U-V V-W W-U Inverter comp Constant comp Comp Copper pipe. Resistance(. ) at 20 C Terminal U-GND V-GND W-GND Inverter comp. 2M. 2M. 2M. Constant comp. 2M. 2M. 2M. Check Point 1. Check the wire connection. (U,V,W) 2. Check the load condition. (Refrigerant, Pipe length, ) Adjust the load condition 3. Check the electricity leakage of the compressor. rmal : Over 2M.. 4. Check the resistance of compressor. rmal : (INV), 0.8. (Cons.) difference at each terminal. 5. Check the insulation from water at IPM part. Check the trace of water. 6. Check the IPM circuit. 31
32 Troubleshooting Guide 6) Troubleshooting CH21, CH22 21 Title Cause of error Check point & rmal condition Max. C/T Over current (14A ) Malfunction of compressor Blocking of pipe Low voltage input Refrigerant, pipe length, blocked, 22 C/T Internal circuit Initial current error Malfunction of current detection circuit. (Open / Short) The voltage of C01N Is 4.0Vdc(25A). V Check Point 1. Check the power source. 2. Check the fan operation is right. 3. Check the current Check the install condition. 5. Check the internal circuit. (C/T, Diode, Resistor) 108 Universal System Air Conditioner
33 Troubleshooting Guide 8) Troubleshooting CH24, CH25 Title Cause of error Check point & rmal condition 24 Press S/W Open Low / High press S/W open. Check the connection of CN_Press. Check the components. 25 Input voltage Abnormal Input voltage (140Vac, 300Vac. Check the power source. Check the components. TRANS1 50Hz, DC12V CN PRESS CN TRNAS1 Check Point CH Check the connection of CN_PRESS 2. Check the install condition for over load. 3. Check the SVC V/V open. 4. Check the leakage of refrigerant. CH Check the power source. 2. Check the components (Trans1, B/Diode, Diode, Resistance) 110 Universal System Air Conditioner
34 Troubleshooting Guide 10) Troubleshooting CH32, CH33 32 Title Cause of error Check point & rmal condition D-pipe (Inverter) temp. high (105 C ) Discharge sensor (Inverter) temp. high Check the discharge pipe sensor for INV. Check the install condition for over load. Check the leakage of refrigerant. Check the SVC V/V open. 33 D-pipe (Constant) temp. high (105 C ) Discharge sensor (Cons.) temp. high Check the discharge pipe sensor for Cons. Check the install condition for over load. Check the leakage of refrigerant. Check the SVC V/V open. D-Pipe temp. Toff(105) C T2(95) C T1(90) C COMP Frequency (Hz) rmal rmal OFF LEV Openness (Pulse) rmal rmal OFF Control Check Point CH Check the install condition for over load. 2. Check the SVC V/V open. 3. Check the leakage of refrigerant. CH Check the install condition for over load. 2. Check the SVC V/V open. 3. Check the leakage of refrigerant. 4. Check the constant compressor. (same with CH21) 34
35 Troubleshooting Guide 11) Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65 Title Cause of error Check point & rmal condition 41 D-pipe sensor (Inverter) Open / Short Soldered poorly Internal circuit error rmal resistor : 200K. / at 25 C (Unplugged) rmal voltage : 4.5Vdc / at 25 C (plugged) 44 Air sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 10K. / at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 45 Condenser Pipe sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 5K. / at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 46 Suction Pipe sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 5K. / at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 47 D-pipe sensor (Constant) Open / Short Soldered poorly Internal circuit error rmal resistor : 200K. / at 25 C (Unplugged) rmal voltage : 4.5Vdc / at 25 C (plugged) 65 Heat sink sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 10K. / at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged). Check Point 1. Estimate the resistance of each sensor.(unplugged) 2. Estimate the voltage of each sensor.(plugged) 3. If the resistance of the sensor is 0 k. or 8, then sensor is abnormal. If the voltage of the sensor is 0 V or 5Vdc, then sensor is abnormal. 35
36 Troubleshooting Guide 12) Troubleshooting CH51, CH60 Title Cause of error Check point & rmal condition 51 Over capacity Over capacity Combination Check the indoor unit capacity. Check the combination table. 60 EEPROM Check sum Check sum error Check the PCB ASM P/. Check the poor soldering. Model Gross max. capacity Max. single indoor unit capacity AUUW126B 21k 12k AUUW186B AUUW246B 24k 12K AUUW306B AUUW366B 33k 18K AUUW k 18K AUUW k 24K Check Point CH Check the indoor unit capacity. CH Check the insertion condition of EEPROM. 2. Check the poor soldering 36
37 Troubleshooting Guide 13) Troubleshooting CH61, CH62 Title Cause of error Check point & rmal condition 61 Condenser pipe sensor temp. high Condenser pipe sensor detected high temp.(65 C) Check the load condition. Check the sensor of Condenser pipe sensor. 62 Heat sink sensor temp. high Heat sink sensor detected high temp.(85 C) Check the fan is locked. Check the sensor of heat sink. Heat Sink temp. Toff C T2 C T1 C COMP Frequency (Hz) rmal rmal OFF rmal Check Point CH Check the install condition for over load. (Refrigerant, Pipe length, Blocked, ) CH Check the fan is locked. 2. Check the Outdoor temp. is very high. 37
38 Troubleshooting Guide Troubleshooting CH54 Title Cause of error Check point & rmal condition 54 Phase error Phase change Check the Main power Check the CN_PHASE connector U V W Phase_A Phase_B 5.3 msec Phase_C Check Point 1. Check the Main power. 2. Check the connecting state of connector CN_3PHASE on the outdoor pcb ass'y. 38
39 LG Multi-split Inverter FM..AH 39
40 6.6 Troubleshooting Indoor Error 4. Trouble Shooting Title Cause of error Check point & rmal condition 01 Indoor air sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 10KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 02 Indoor inlet pipe sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 5KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 06 Indoor outlet pipe sensor Open / Short Soldered poorly Internal circuit error rmal resistor : 5KΩ/ at 25 C (Unplugged) rmal voltage : 2.5Vdc / at 25 C (plugged) 10kΩ 2.5Vdc Ω V Check the resistance Check the voltage Check Point 1. Unplug the sensor on Indoor unit PCB. 2. Estimate the resistance of each sensor. 3. If the resistance of the sensor is 10KΩ/ 5KΩ at 25 C, then sensor is normal. 4. If the resistance of the sensor is 0 KΩ or, then sensor is abnormal. Change the sensor. 5. Plug the sensor on Indoor unit PCB and Power ON. 6. Estimate the voltage of each sensor. 7. If the voltage of the sensor is 2.5Vdc at 25 C, then sensor is normal. 8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. Repair or Change the PCB. Copyright 2007 LG Electronics. Inc. All right reserved
41 4. Trouble Shooting 03 Title Cause of error Check point & rmal condition Communication Wired R/C Open / Short Wrong connection Connection of wire Main PCB Volt. DC12V ise interference Wired R/C 12V S GND Indoor Unit 12V S GND CN-REMO 12Vdc 12Vdc V V Check the Volt. Check the Volt. Check Point 1. Check the wire connection. (Open / Short) Repair the connection 2. Check the soldering state of connector. (Soldered poorly) Repair or Change the PCB. 3. Check the volt. Of main PCB power source. (DC 12V, DC 5V) Repair or Change the main PCB. 4. Check the installation of wired remote controller. (ise interference) Adjust the state of installation Copyright 2007 LG Electronics. Inc. All right reserved
42 4. Trouble Shooting 04 Title Cause of error Check point & rmal condition Drain pump / Float switch Float switch Open. (rmal : short) The connection of wire(drain pump/ Float switch) Drain pump power input. (220V) Drain tube installation. Indoor unit installation. (Inclination) CN Float 0Ω CN-Float CN-D/PUMP Ω Check the resistance Check Point 1. Check the wire connection. (Open, Soldered poorly) Repair the connection or change the PCB. 2. Check the resistance of float switch (Abnormal : Open, rmal : short) Check the float switch. 3. Check the level of water 4. Check the volt. Of Drain pump power supply. (AC 230V) Repair or Change the main PCB. Copyright 2007 LG Electronics. Inc. All right reserved
43 4. Trouble Shooting 6.7 Troubleshooting Outdoor Error FM15AH t/m FM25AH 05 / 53 Title Cause of error Check point & rmal condition Communication (Indoor Outdoor) Communication poorly Power input AC 220V. (Outdoor, Indoor) The connector for transmission is disconnected. The connecting wires are misconnected. The GND1,2 is not connected at main GND. The communication line is shorted at GND. Transmission circuit of outdoor PCB is abnormal. Transmission circuit of indoor PCB is abnormal. Check Point 1. Check the input power AC230V. (Outdoor, Indoor unit) 2. Check the communication wires are correctly connected. Adjust the connection of wire Confirm the wire of Live, Neutral 3. Check the resistance between communication line and GND. (rmal : Over 2MΩ) 4. Check the connector for communication is correctly connected. 5. Check the connection of GND1, GND2, and main GND. 6. If one indoor unit is operated normally, outdoor PCB is no problem. Check the another indoor unit. * CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit. Copyright 2007 LG Electronics. Inc. All right reserved
44 Multi-split: Inverter FM..AH 4. Trouble Shooting FM27AH t/m FM57AH Title 05 / 53 Title Communication (Indoor Outdoor) Cause of error Communication poorly Check point & rmal condition Power input AC 220V. (Outdoor, Indoor) The connector for transmission is disconnected. The connecting wires are misconnected. The communication line is shorted at GND. Transmission circuit of outdoor PCB is abnormal. Transmission circuit of indoor PCB is abnormal. Check Point 1. Check the input power AC230V. (Outdoor, Indoor unit) 2. Check the communication wires are correctly connected. Adjust the connection of wire Confirm the wire of "Live", "Neutral" 3. Check the resistance between communication line and GND. (rmal : Over 2MΩ) 4. Check the connector for communication is correctly connected. 5. If one indoor unit is operated normally, outdoor PCB is no problem. Check the another indoor unit. * CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit. 6. If all indoor unit is displayed CH05 but outdoor PCB not display CH53 : Check the CN_COM and CN_POWER is correctly connected. L N < TERMINAL BLOCK > 27/30/40k 1. In Case of CH53, Check the Connection L, N at the terminal block 48/56k 1. In Case of CH05, Check the Connection CN-POWER, CN-COMM at the Main PCB 2. In Case of CH53, Check the Connection CN-COMM at the Main PCB L, N at the terminal block L N N L N CN-COMM CN-Power < MAIN PCB > Copyright 2007 LG Electronics. Inc. All right reserved
45 4. Trouble Shooting 21 Title Cause of error Check point & rmal condition DC PEAK (IPM Fault) Instant over current Over Rated current Poor insulation of IPM An instant over current in the U,V,W phase - Comp lock - The abnormal connection of U,V,W Over load condition - Overcharging of refrigerant Pipe length. Outdoor Fan is stop Poor insulation of compressor Error Diagnosis and Countermeasure Flow Chart Is installation condition normal? Are the resistance Between each phase and insulation resistance of Inverter compressor normal? Is compressor Wire connection condition normal? 1. Check Pipe clogging/distortion 2. Check Covering (Indoor/Outdoor Unit) 3. Check EEV connector assemble condition/normal operation 4. Check refrigerant pressure Reassemble or manage if abnormality found 1. Check resistance between each terminal of compressor (1.083~1.123Ω ±5%) 2. Check insulation resistance between compressor terminal and pipe (over 50M ) Replace compressor if abnormality found 1. Check inverter PCB assembly U,V,W connector connection condition 2. Check wire disconnection and wiring 3. Check compressor terminal connection condition (bad contact) Reassemble if abnormality found Is inverter PCB assembly normal? Check inverter PCB assembly IPM normality Replace inverter PCB assembly Recheck power and installation condition Comp checking method Comp U Resistance(Ω) at 20 C Ω Terminal Inverter comp. V W U-V V-W W-U Comp Copper pipe Ω Resistance(Ω) at 20 C Terminal U-GND V-GND W-GND Inverter comp. 50MΩ 50MΩ 50MΩ Copyright 2007 LG Electronics. Inc. All right reserved. 45
46 Multi-split: Inverter FM..AH FM15AH t/m FM25AH 4. Trouble Shooting 1. Wait until inverter PCB DC voltage is discharged after main power off. 2. Pull out CN-L1(R), CN-L2(S), CN-L3(T) and CN-COMP Connector. 3. Set multi tester to resistance mode. 4. If the value between P and N terminal of IPM is short(0ω) or open(hundreds MΩ), PCB needs to be replaced.(ipm damaged) 5. Set the multi tester to diode mode. 6. In case measured value is different from the table, PCB needs to be replaced.(pcb damaged). P U V W Nu Nv Nw P U V W Nu Nv Nw ~ 0.6 V 0.4 ~ 0.6 V PFC_IPM check U, V, W R S T CAUTION In case that the control box is opend and before checking electrical parts, it should be checked that the LED 01M, 02M turned off(wait 7 minutes after main power OFF), otherwise it may cause electrical shock. Copyright 2007 LG Electronics. Inc. All right reserved. 46
47 4. Trouble Shooting 21 Title Cause of error Check point & rmal condition DC PEAK (IPM Fault) Instant over current Over Rated current Poor insulation of IPM An instant over current in the U,V,W phase - Comp lock - The abnormal connection of U,V,W Over load condition - Overcharging of refrigerant Pipe length. Outdoor Fan is stop Poor insulation of compressor Error Diagnosis and Countermeasure Flow Chart Is installation condition normal? Are the resistance Between each phase and insulation resistance of Inverter compressor normal? Is compressor Wire connection condition normal? 1. Check Pipe clogging/distortion 2. Check Covering (Indoor/Outdoor Unit) 3. Check EEV connector assemble condition/normal operation 4. Check refrigerant pressure Reassemble or manage if abnormality found 1. Check resistance between each terminal of compressor (0.34~0.35 7%) 2. Check insulation resistance between compressor terminal and pipe (over 50M ) Replace compressor if abnormality found 1. Check inverter PCB assembly U,V,W connector connection condition 2. Check wire disconnection and wiring 3. Check compressor terminal connection condition (bad contact) Reassemble if abnormality found Is inverter PCB assembly normal? Check inverter PCB assembly IPM normality Replace inverter PCB assembly Recheck power and installation condition Comp checking method V Comp U W Ω Resistance(Ω) at 20 C Terminal U-V V-W W-U Inverter comp Constant comp Comp Copper pipe Ω Resistance(Ω) at 20 C Terminal U-GND V-GND W-GND Inverter comp. 2MΩ 2MΩ 2MΩ Constant comp. 2MΩ 2MΩ 2MΩ Copyright 2007 LG Electronics. Inc. All right reserved
48 Multi-split: Inverter FM..AH 4. Trouble Shooting FM27AH t/m FM41AH LED01M LED02M U,V,W CONNECTOR U V W 1. Wait until inverter PCB DC voltage is discharged after main power off. 2. Pull out V, V, W COMP connector. 3. Set multi tester to resistance mode. 4. If the value between P and N terminal of IPM is short(0ω) or open(hundreds MΩ), PCB needs to be replaced.(ipm damaged) 5. Set the multi tester to diode mode. 6. In case measured value is different from the table, PCB needs to be replaced.(pcb damaged). P U V W Nu Nv Nw P U V W Nu Nv Nw ~ 0.6 V 0.4 ~ 0.6 V PFC_IPM chec U, V, W R S CAUTION In case that the control box is opend and before checking electrical parts, it should be checked that the LED 01M, 02M turned off(wait 7 minutes after main power OFF), otherwise it may cause electrical shock. Copyright 2007 LG Electronics. Inc. All right reserved. 48
49 Multi-split: Inverter FM..AH 4. Trouble Shooting FM49AH t/m FM57AH U V W LED01M LED02M CN(L)_BRWON CN(N)_BLUE U,V,W CONNECTOR 1. Wait until inverter PCB DC voltage is discharged after main power off. 2. Pull out CN(L), CN(N) connectors and U,V,W COMP Connector. 3. Set multi tester to resistance mode. 4. If the value between P and N terminal of IPM is short(0ω) or open(hundreds MΩ), PCB needs to be replaced.(ipm damaged) 5. Set the multi tester to diode mode. 6. In case measured value is different from the table, PCB needs to be replaced.(pcb damaged). P U V W Nu Nv Nw P U V W Nu Nv Nw ~ 0.6 V 0.4 ~ 0.6 V PFC_IPM chec U, V, W R S CAUTION In case that the control box is opend and before checking electrical parts, it should be checked that the LED 01M, 02M turned off(wait 7 minutes after main power OFF), otherwise it may cause electrical shock. Copyright 2007 LG Electronics. Inc. All right reserved
50 4. Trouble Shooting Title Cause of error Check point & rmal condition 22 Max. C/T Input Over Current 1. Malfunction of Compressor 2. Blocking of Pipe 3. Low Voltage Input 4. Refrigerant, Pipe length, Blocked... Error Diagnosis and Countermeasure Flow Chart Is installation condition normal? Are the resistance Between each phase and insulation resistance of Inverter compressor normal? Is compressor Wire connection condition normal? 1. Check Pipe clogging/distortion 2. Check Covering (Indoor/Outdoor Unit) 3. Check EEV connector assemble condition/normal operation 4. Check refrigerant pressure Reassemble or manage if abnormality found 1. Check resistance between each terminal of compressor 1.083~1.123Ω ±5% 2. Check insulation resistance between compressor terminal and pipe (over 50MΩ ) Replace compressor if abnormality found 1. Check inverter PCB assembly U,V,W connector connection condition 2. Check wire disconnection and wiring 3. Check compressor terminal connection condition (bad contact) Reassemble if abnormality found Is inverter PCB assembly power connection normal? Check connection between inverter PCB assembly and bridge diode(misconnection, disconnection) wiring again if abnormality found Is input voltage normal? Check R~S/S~T/T~R phase voltage is 380V ±10% R~N/S~N/T~N phase voltage is 220V ±10% Check connection condition and wiring if power is abnormal. Is inverter PCB assembly normal? Check inverter PCB assembly IPM normality Replace inverter PCB assembly Recheck power and installation condition Copyright 2007 LG Electronics. Inc. All right reserved
51 Check Point 1. Check the power source.(200~240v) 2. Check the fan operation is right. 3. Check the current. 4. Check the install condition. 5. Check the CT Sensor Output signal (Check output pin 1.2 of the CT Sensor : 5V ) 4. Trouble Shooting Tester CT Sensor Output (at the INVERTER PCB) Copyright 2007 LG Electronics. Inc. All right reserved
52 4. Trouble Shooting 22 Max. C/T Title Cause of error Check point & rmal condition Input Over Current(27/30/40k-17A 48/56k-29A ) 1. Malfunction of Compressor 2. Blocking of Pipe 3. Low Voltage Input 4. Refrigerant, Pipe length, Blocked... Error Diagnosis and Countermeasure Flow Chart Is installation condition normal? Are the resistance Between each phase and insulation resistance of Inverter compressor normal? Is compressor Wire connection condition normal? 1. Check Pipe clogging/distortion 2. Check Covering (Indoor/Outdoor Unit) 3. Check EEV connector assemble condition/normal operation 4. Check refrigerant pressure Reassemble or manage if abnormality found 1. Check resistance between each terminal of compressor (0.188 ±7%) 2. Check insulation resistance between compressor terminal and pipe (over 50MΩ ) Replace compressor if abnormality found 1. Check inverter PCB assembly U,V,W connector connection condition 2. Check wire disconnection and wiring 3. Check compressor terminal connection condition (bad contact) Reassemble if abnormality found Is inverter PCB assembly power connection normal? Check connection between inverter PCB assembly and bridge diode(misconnection, disconnection) wiring again if abnormality found Is input voltage normal? Check L~N phase is 220V ±15% Check connection condition and wiring if power is abnormal Is inverter PCB assembly normal? Check inverter PCB assembly IPM normality Replace inverter PCB assembly Recheck power and installation condition Copyright 2007 LG Electronics. Inc. All right reserved
53 FM27AH t/m FM57AH Multi-split: Inverter FM..AH 4. Trouble Shooting Check Point 1. Check the power source.(220v ±15%) 2. Check the fan operation is right. 3. Check the current. 4. Check the install condition. 5. Check the CT Sensor Output signal (27/30/40k - Check output the CT Sensor : DC 2.5±0.2V) (48/56k - Check output pin 1.2 of the CT Sensor : 5V ) Vdc < Input Power Source Check Point > < Main PCB> <CT Sensing Check Point> < Inverter PCB> Copyright 2007 LG Electronics. Inc. All right reserved. <CT Sensing Check Point>
54 4. Trouble Shooting Title Cause of error Check point & rmal condition 23 DC Link Low voltage DC Link volt is below 300V Check point & rmal condition Check the TAB1 is connect. At not operating : DC Link voltage(260v ) At Comp operating : DC Link voltage(500v ) Error Diagnosis and Countermeasure Flow Chart Is DC Link voltage under 380V? Check the DC link Voltage AD Input of Inverter PCB If AD Input is strange, change the Inverter PCB (refer the next page.) Is input voltage normal? R~S/S~T/T~R phase voltage is 400V ±10% R~N/S~N/T~N phase voltage is 220V ±10% Check connection condition and wiring if power is abnormal. Is Inverter PCB assembly Power connection normal? Check connection from terminal block to Inverter PCB assembly CN_L1(R), CN_L2(S), CN_L3(T) Is Inverter PCB rmal? Replace inverter PCB assembly Recheck power and installation condition Copyright 2007 LG Electronics. Inc. All right reserved
55 FM15AH t/m FM27AH Multi-split: Inverter FM..AH 4. Trouble Shooting Check Point 1. Check the Tab1 connection condition. (Refer to outdoor wiring diagram) 2. Check the CN_L1(R), CN_L2(S), CN_L3(T) connection condition 3. Check the DC Link voltage at not operating(380v ) 4. Check the DC Link voltage at Comp operating(500v ) 5. Check DC Link Sensing Signal (Refer the Picture) Vdc 500Vdc ±10% + GND <INVERTER PCB> <DC Link Voltage Check Point> GND Tester DC Link Voltage oltage INV <INPUT VOLTAGE Check Point> Copyright 2007 LG Electronics. Inc. All right reserved
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More information14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
More informationSplit and Multi Split air conditioners Service information
Split and Multi Split air conditioners Service information Programming LG wired controllers 2 New type 2 Old type 7 Fault codes 9 Wall units (single split) 9 Universal split and multi split 10 Detailed
More informationService manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V
Resistance The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V 9.2 Troubleshooting for indoor unit E0 E1 E2 E3 E5 E6 P0
More informationSERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/
SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the
More information13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit
Troubleshooting 13. Troubleshooting Indoor unit s LED indication of Corona DC inverter unit MCAC-HTSM-2007-11 E0 E1 E2 E3 E5 E6 P0 P1 P2 P3 P5 EEPROM error outdoor communication error Zero-crossing examination
More informationIndoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More informationTechnical service manual 2009
MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual 2009 KSIM MULTI ZONE SERIES R410A DC Inverter multi Series Models KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 CONTENT 1. Product features
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationTAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O
SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O DC MULTI OUTDOOR UNITS CONTENTS 1. General information of Outdoor Units... 3 2. Dimensions... 4 3. Wiring Diagram...
More informationService manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
More informationHaier Air conditioner
For Europe Haier Air conditioner HAND in HAND HIGHER and HIGHER Page:1 For Europe HSU-09/12HVA103/R2(DB) HSU-09/12RHA103/R2(DB) Page:2 Error Codes and Description indoor and outdoor display(1) indoor Code
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationPANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
More informationTechnical service manual
GD Midea Refrigeration Equipment Co.,Ltd ODMI-A-1202 MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual R410A Multi DC inverter 220~240V-1Ph-50Hz Outdoor units Models M2OC-14HRDN1 M2OC-14HRDN1-Q
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL
More information1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target
4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection
More informationRepair Guideline for TCL DC Inverter Air Conditioner
Repair Guideline for TCL DC Inverter Air Conditioner FLOS SERIE---V3 0 CONTENTS Ⅰ. Introduction of New control board for outdoor unit...2 1. The structure of control board... 2 2. Diagram of outdoor unit........4
More informationsip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
More informationFILE NO. SVM-07013 11. HOW TO DIAGNOSE THE TROUBLE
FILE. SVM-070. HOW TO DIAGSE THE TROUBLE The pulse motor circuits are mounted to both indoor and outdoor units. Therefore, diagnose troubles according to the trouble diagnosis procedure as described below.
More informationSi10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
More informationSERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
More informationSimple Self-Diagnosis by Malfunction Code
Simple Self-Diagnosis by Code After Sales Service Division (SM-TS2) Detail Division 0 Indoor Unit System Others A C E F H J L P U M 7 8 9 External device activated (unified) Protection devices activated
More information10.1 Indoor Unit Error Display
10.1 Indoor Unit Error Display Display E0 E1 E2 E3 E5 E6 P0 P1 P2 P4 LED STATUS EEPROM parameter error Indoor / outdoor units communication protection Zero-crossing signal error Fan speed out of control
More informationAIR CONDITIONER OUTDOOR UNIT. Product Specifications. Disassembly and Reassembly. Troubleshooting. PCB Diagram. Wiring Diagram.
SYSTEM AIR CONDITIONER OUTDOOR UNIT AM036FXMDCH AM048FXMDCH AM053FXMDCH AIR CONDITIONER CONTENTS Product Specifications Disassembly and Reassembly Troubleshooting PCB Diagram Wiring Diagram Reference Sheet
More informationAIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
More informationHITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS
HITACHI INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS SET FREE FSG(1)/FS3, FS5 SERIES AND SET FREE FXG/FX3 SERIES Models In-the-Ceiling Type RPI-0.8FSG1 RPI-2.5FSG1 RPI-8FSG1
More informationMP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
More informationRoom Air Conditioner SVC MANUAL(General)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(General) MODEL : General Wall Mounted-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General
More informationRepair Guideline for SANYO New Erp. DC Inverter Air Conditioner (Published in May, 2013)
Repair Guideline for SANYO New Erp DC Inverter Air Conditioner (Published in May, 2013) Contents I. Electronic Control of DC Inverter Air Conditioner 2 1. Main parts of the electronic control of DC inverter
More informationSingle Zone Air Conditioner SVC MANUAL(General)
Single Zone Air Conditioner SVC MANUAL(General) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 960-914-06 Air Conditioner Service
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A5UW306FA3 CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
More informationHow To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationPanasonic/Sanyo A/C Interface Modbus RTU Installation Instructions
Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions Preface Safety warnings To avoid injury, or damage to the Modbus interface, read all installation and configuration instructions in this
More informationSERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FE18NA has been added. Please void OBH543. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 REVISED EDITION-A Models MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA Indoor
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationSERVICE MANUAL AE-X2M14LR MULITI SPLIT TYPE ROOM AIR CONDITIONERS (OUTDOOR UNIT) MODEL. No. S2038AEX2MLRT CONTENTS AEX2M14LR
TopPage AEX2M14LR SERVICE MANUAL. S2038AEX2MLRT MULITI SPLIT TYPE ROOM AIR CONDITIONERS (OUTDOOR UNIT) MODEL AE-X2M14LR In the interests of user-safety (Required by safety regulations in some countries)
More informationRepair Guideline for TCL DC Inverter Air Conditioner
Repair Guideline for TCL DC Inverter Air Conditioner Contents I. Electrical Control of Inverter Air Conditioner 2 1. Main compositions of the electrical control of inverter air conditioner 2 2. Wiring
More informationSERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationModel: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
More informationService Manual. Heat Pump and Heat Recovery Variable Refrigerant Flow Outdoor Units 6.0 to 42.0 Tons
SM-MultiV-IV-Air-Outdoor-Units-4-15 Heat Pump and Heat Recovery Variable Refrigerant Flow Outdoor Units 6.0 to 42.0 Tons Service Manual Heat Pump 208 / 230V, 60Hz, 3-phase and 460V, 60Hz, 3-phase ARUN072BTE4
More information800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
More informationSERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED
More informationINSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
More informationFault Code Check List
FAULT COVER&TABS_COVERS 26/09/2011 17:14 Page 1 Fault Code Check List This Fault Code Check List is intended to provide an easy-to-use, quick reference guide on all Fault Codes across our product range.
More informationDTC B1423/23 Pressure Sensor Circuit
AIR CONDITIONI AIR CONDITIONI SYSTEM (for Manual Air Conditioning System) 145 DTC B1423/23 Pressure Sensor Circuit DESCRIPTION This DTC is output when the refrigerant pressure is either extremely low (0.19
More informationInstruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
More informationUser Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1
User Manual Hybrid 1KW-5KW INVERTER / CHARGER Version: 1.1 Table of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Product Overview... 3 INSTALLATION...
More informationUSER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
More informationUser s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
More informationTechnical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
More informationAUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM
SECTION 7D AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM TABLE OF CONTENTS Description and Operation... 7D- General... 7D- FATC Control... 7D- FATC Input/Output Routing Diagram...
More informationEVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
More informationUSER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
More informationLG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
More informationCAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
More informationPanel Mounted Air Conditioners by Dantherm, Inc.
Panel Mounted Air Conditioners by Dantherm, Inc. CS020020A/B with USACG-6 Control PRODUCT INFORMATION MANUAL AC-2 CS020020 USACG-6 Manual Rev H Page 1 of 17 Dantherm, Inc. 110 Corporate Drive, Suite K
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
More informationSERVICE Manual AIR CONDITIONER INDOOR UNIT AS30C2BC OUTDOOR UNIT US30C2BC. 1. Installation. 2. Disassembly and Reassembly. 3.
ROOM AIR CONDITIONER INDOOR UNIT AS30C2BC OUTDOOR UNIT US30C2BC SERVICE Manual AIR CONDITIONER. Installation CONTENTS 2. Disassembly and Reassembly 3. Troubleshooting 4. Exploded Views and Parts List 5.
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH
More informationgood sleep Mode good sleep mode can help you sleep quickly and soundly and wake up refreshed.
good sleep Mode good sleep mode can help you sleep quickly and soundly and wake up refreshed. Catech in Filter Silver Nano Evap orator Deo dorizing Filter then withclean,refreshin air Model AQ09VFUAGM/CV
More informationAIR CONDITIONER OUTDOOR UNIT. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting
SYSTEM AIR CONDITIONER OUTDOOR UNIT AIR CONDITIONER CONTENTS 1. Precautions 2. Product Specifications 3. Disassembly and Reassembly 4. Troubleshooting 5. PCB Diagram and Parts List 6. Wiring Diagram 7.
More informationMDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
More informationPORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
More informationCAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual
Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description
More informationSERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
More informationUser Guide. Model 380260 Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
More informationSERVICE MANUAL. Room Air Conditioner Split Wall-Mounted Type. FSAI-Pro-91AE2 / FSOAI-Pro-91AE2. FSAI-Pro-241AE2 / FSOAI-Pro-241AE2
SERVICE MANUAL Room Air Conditioner Split Wall-Mounted Type FSAI-Pro-91AE2 / FSOAI-Pro-91AE2 FSAI-Pro-121AE2 / FSOAI-Pro-121AE2 FSAIF-Pro-181AE2 / FSOAIF-Pro-181AE2 FSAI-Pro-241AE2 / FSOAI-Pro-241AE2 NOTE:
More informationHVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC
HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC Page. Basic Diagnostic Procedure.... General Description...3 3. Electrical Components Location...6 4. A/C Control Module I/O Signal...8 5. Self-diagnosis...0 6.
More informationAutomatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
More informationESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE Protected by one or more of the following U.S. Patents (3,507,354; 3,575,234; 3,596,936; 3,605,797; 3,685,329; 4,045,977; 4,698,982; 926,673 and
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationSERVICE & MAINTENANCE MANUAL
SERVICE & MAINTENANCE MANUAL 2005 TABLE OF CONTENTS PAGE NO. 1. Precautions for Service & Maintenance 2 2. Split System Description 3 3. Unit Model Designation & Identification 4 4. Unit Models & Part
More informationSERVICE MANUAL INDOOR UNIT
SPLIT-TYPE AIR CONDITIONERS Revision B: "How to check miswiring and serial signal error" for MUZ type has been added. The description about "Low standby power control" has been added to "TECHNICAL CHANGES".
More informationHAIER WINDOW TYPE AIR CONDITIONER. Service Manual. Part # AC-8888-104. HAIER TRADING COMPANY, LLC www.haieramerica.com
HAIER WINDOW TYPE AIR CONDITIONER Service Manual Part # AC-8888-104 HAIER TRADING COMPANY, LLC www.haieramerica.com 1 SERVICE MANUAL Models HWR08XC5 ESA3065 ESA3085 Features Top-Discharge Air Flow Ultra
More informationRoom Air Conditioner Service and Parts Manual
Fan Only Cool Dry Money Saver Temp Room Air Conditioner Service and Parts Manual Mode Timer 0n/ 0ff 0F hr Fan Speed Auto Swing Power 115Volts CP10F10 CP12F10 CP10 - CP12 Svc Parts 2010 (05/10) Air Conditioner
More informationGas Oven Repair Guide
- /6 - Gas Oven Repair Guide [ FX70*, FX50*] Ver. Aug-0 Ignition Failure Cooktop ignition Oven ignition Heating defect Oven Cooktop Abnormal Flame Button, Motors Lamp Others Smell, Smoke, Noise No Display,
More informationCAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationLOCAL INTERCONNECT NETWORK (LIN)
54B-1 GROUP 54B LOCAL INTERCONNECT NETWORK (LIN) CONTENTS GENERAL INFORMATION 54B-2 SPECIAL TOOLS 54B-3 54B-4 DIAGNOSIS FUNCTION 54B-4 DIAGNOSTIC TROUBLE CODE CHART 54B-6 DIAGNOSTIC TROUBLE CODE PROCEDURES
More informationA/C-HEATER SYSTEM - AUTOMATIC
A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationSplit-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
More informationSERVICE & MAINTENANCE MANUAL
SERVICE & MAINTENANCE MANUAL Specifications are subject to change without notice according to Carrier Policy of continuous development. 03502566 Revision : (0) - 2009 TABLE OF CONTENTS PAGE NO. 1. Precautions
More informationPortable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
More informationMatch. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More informationINDEX MITSUBISHI HEAVY INDUSTRIES - PAC SERVICE MANUAL MAINTENANCE DATA 2 ERROR CODES 4 PCB INDOOR UNITS 8 ERROR DISPLAY & REMEDY CHART 12
SERVICE MANUAL FDA Series Split Systems FDA Series Multi Systems MITSUBISHI HEAVY INDUSTRIES - PAC SERVICE MANUAL INDEX MAINTENANCE DATA 2 ERROR CODES 4 PCB INDOOR UNITS 8 ERROR DISPLAY & REMEDY CHART
More informationMulti Air Conditioner SVC MANUAL(General)
Internal Use Only http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(General) MODEL : Multi-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only
More informationRoom Air Conditioner SVC MANUAL(General)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(General) MODEL : General Wall Mounted-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationWALL MOUNTED AIR CONDITIONER SERVICE MANUAL 11M INVERTER
WALL MOUNTED AIR CONDITIONER SERVICE MANUAL 11M INVERTER This manual applies to the models: 42HVM109303 / 38HVM109303(P) 42HVM112303 / 38HVM112303(P) 42HVM118303 / 38HVM118303(P) 42HVM124303 / 38HVM124303(P)
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402
TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE
More informationBITMAIN. APW3-12-1600 PSU Series User Guide
BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...
More informationSERVICE MANUAL MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA INDOOR UNIT. No. OBH647. Models. Revision A: MSZ-HJ50VA- E1 has been added.
SPLIT-TYPE AIR CONDITIONERS Revision A: MSZ-HJ50VA- E1 has been added. Please void OBH647. INDOOR UNIT SERVICE MANUAL. OBH647 REVISED EDITION-A Models MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA - E1 - E1 - E1 CONTENTS
More information