Mounting and System Description for SSZ-Safety-Mats

Similar documents
Tina 2A/B Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

instabus KNX / EIB System System E F G H

PUSH BUTTON START INSTALLATION MANUAL

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

SMS 4 / SMS 5 safety mat Product information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Electrical connection

Modular I/O System Analog and Digital Interface Modules

Charge Controller CC611/CC612 Preliminary datasheet

Cable Plug acc. to DIN EN , Form A

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

Electronic Pressure Switch EDS 300

PERCEDOS. Instruction Manual/Technical Information PERCEDOS

SKR - industry relay

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Phone: Fax: Web: info@clrwtr.com

Fitting/Installation Guide - UNIVERSAL

ATL Fuel Level Sender Probes

Smile 11 AS-i Emergency stop with safe AS-i input node

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

Inwall 4 Input / 4 Output Module

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

User manual DinaSys DTC/DTS and DTC/DTZ

DALI RC BASIC SO. Control unit Operating instructions

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

WE-350 Series ¼ Turn Electric Actuator

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Proximity Switches RS (Reed Switch)

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Combi B Alarm box. Mounting instructions

Shunt lock function 3066

Product and functional description

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Digital Keypad Use s Manual

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

PTU Series Transducer Digital Display Indicator User s Manual

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

IMR 6000/10../20../30

The Child Reminder System Installation Manual


Model 201 Wiegand Touchpad Reader Installation Guide

SECURITY SYSTEM ADP-CAN

US Installation Manual Smappee Monitor

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

7 Lighting Technology

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

KVT-729DVD INSTALLATION MANUAL

Product Information Sheet UH28CS-12kV Hi Pot Tester

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

LED - Indicator Panels

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

WHO ANSWERED FIRST? FIND OUT WITH THIS QUIZ BUZZER KIT

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

INSTALLATION AND OPERATION MANUAL

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

PROXIMITY CARD READERS C-10, C-20, C60, C70

Installation & User Manual Radio Remote rev1.0.3

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Elektromotoren und Gerätebau Barleben GmbH

Charge Regulator SCR 12 Marine

user manual smappee monitor

Drayton Digistat +2RF/+3RF

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

mpm DIN CONNECTORS

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

TMS TANK MANAGEMENT SYSTEM

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

SYSTEM 4C. C R H Electronics Design

ADM1TE 5/30A DIN rail single phase two wire energy meter

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

!Operation:!1. Connect an external power source to J1 (+ and - IN terminals). The

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

CARD CUTTER MACHINE STUDENT.MANUAL

Operating Instructions. UL325 Compliant Non-monitored

WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

12 Volt 30 Amp Digital Solar Charge Controller

Digital display DA 48

Short information Parameters are programmed via front-side membrane keypad

GAE953 Electrical Alarm Unit 19" with Indicator

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RRV934. Multi-controller. Synco living

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

DEVIreg 330 (+5 to +45 C)

Transcription:

Mounting and System Description for SSZ -GmbH Sicherheits- Systeme Zimmermann Thüringerstraße 17 46286 Dorsten )+492369/4094-5 Fax +492369/21597

1 10 The function test of the SSZ-safety mat: The SSZ-safety mat can be tested with help of multi gage or an electric resistance meter. For a function test the mat has to be disconnected from the controller and other connected safety components. The measuring points and results are listed in the following table. Further SSZ Products: - Safety Switching Rails - Safety Bumper - Floor Switches - Protection of shelving alleys PSA/P Connection point Measuring range Measuring result Wire 3/ Wire 4 Wires 5/ 6 open Wire 3/ Wire 4 Wires 5/ 6 shorted Wire 3/ Wire 5 Wire 4/ Wire 6 20 M Ohms 400 K Ohms 200 K Ohms 200 K Ohms <400 K Ohms <140 K Ohms <140 K Ohms - Protection of Fork-lift trucks PSA/S - Special devices and developments The resistance between wire 3 and wire 5 should have approximately same value as the resistance between wire 4 and wire 6.

9 2 Table for connecting two SSZ-safety-mats: 1 x 4 wire connection cable with 4- pole plug Mat #1 Wire no./ colour 3/ blue 4/ brown 5/ black 1 x 4 wire fixed connection cable Connect to Controller clamp 3 Controller clamp 4 Mat #2 wire 3/ blue Mat #2 wire 4/ brown Mat #2 5/ black Controller clamp 5 Controller clamp 6 Mat #1 Wire no./ colour 3/ green 4/ brown 5/ yellow Connect to Controller clamp 3 Controller clamp 4 Mat #2 wire 3/ green Mat #2 wire 4/ brown Mat #2 5/ yellow Controller clamp 5 Controller clamp 6 Application SSZ-safety-mats are areal protections with integrated sensor element and can only be used with controller Type SSZ-AE-N, SSZ-SS-N, SSZ-SQ-N and SSZ-SQP-N. SSZ-safety-mats protect the dangerous working areas on machines and plants and prevent injuries or damage or reduce them to a minimum. SSZ-safety-mats can be used where areas have to be protected. The safety mat/controller fulfils the requirements stage 2 (SSZ-AE-N) or the requirement stage 3 according to pren 954-1. Areas of Application Types - for computer controlled devices - for driverless floor conveying vehicles - for dangerous areas within machines and units - for protecting crushing points and cutting points and many more. SSZ-safety-mats are manufactured on customer demand. The maximum dimensions are 3000 mm x 1500mm. To protect a greater area it is possible to attach several SSZ-safety-mats. Note - the controllers are only allowed to be used in rooms with a minimum protection acc. to IP 54. - the systems have to be checked by the user at least once per day to ensure that they function perfectly. - the valid safety regulations and accident prevention regulations must be observed by the user. - the controller can only be used in voltage circuits that comply with at least the same safety standards.

3 8 Safety Category The SSZ-controller type SSZ-SS-N, SSZ-SQ-N and SSZ-SQP-N apply with the safety category 3. The SSZ-controller type SSZ-AE-N applies with the safety category 2. If two or more SSZ-safety-mats are connected to a controller they have to be connected in series. Please pay attention to the following connection diagramm an the tables on the following page. Approvals The SSZ-safety components are approved according to to the above named safety categories for accident prevention. The according "Baumusterprüfung" is held by the TÜV Hannover/ Sachsen-Anhalt e.v. Important Note The user has to take relevant measures to prevent independent starting after power cuts and starting an emergency stop facility acc. to VDE 0113 T1, 1986, para. 5.5.1.2. Black White Brown Blue Blue Brown Black White Reset push button (Only SQ-N and SQP-N) Operating Voltage A1 S1 S2 3 4 5 6 A2 13 14 23 24 33 34 41 42 Safe release

7 4 The reset of the controller is done by falling edge. This means that the output relais do not resume working condition and the contacts do not close until the contact of the reset button has been opened. Through this measure a by-pass off the reset button is impossible. At last the operating voltage should be connected to the clamps A1 and A2. After this the SSZ-safety-mat should be checked by several activations. Like all SSZ-safety components, SSZ-safety-mats are constructed in a 4 wire system to ensure the highest safety standards. The sensor element which is integrated into the SSZ-safety-mat, conducts 2 signals that are produced by the controller via the sensing area. Signal # 1 To controller Signal # 2 To controller Blue Brown Black White Signal # 1 From controller Reset push button (Only SQ-N and SQP-N) Signal # 2 From controller Operating Voltage A1 S1 S2 3 4 5 6 A2 13 14 23 24 33 34 41 42 Safe release These signals are fed back to the controller via the 4 wire connection cable. When the mat is actuated, the signal conducting contact areas touch each other whereby the signals change. This changing of the signals is transmitted to the output relais K1 and K2 in the controller. Hereby the relais contacts open. This means that the emergency stop circuit of the machine in which the contacts are included, is interrupted and the dangerous movement is prevented.

5 6 If there is any interruption (cable break etc.) in an individual wire in the connection cable or the signal transmitter, the controller no longer receives an appropriate signal. This is indicated by the extinction of one of the two yellow diodes. By this the output relais K1 and K2 decline and the emergency stop circuit of the machine is opened. At a crush-closing or the cutoff of the connection cable these two output relais also decline. The switching condition of the relais is displayed via light emmitting diodes (LED) on the controller. The function of the LEDs is shown in the following table. Name of the LED Colour Function Ub RDY (K1) ON (K1) OFF (K1) RDY (K2) red yellow green red yellow operating voltage signal on clamp 5 relais K1 tightened relais K1 declined signal on clamp 6 ON (K2) green relais K2 tightened OFF (K2) red relais K2 declined The SSZ-safety-mat as well as its connection cable are permanently controlled through this wiring and with the assistance of the controller. The SSZ-safety-mat is mounted to the appropriate part of the machine by the supplied aluminium edging. The controller must be installed in the controlling housing, switch cabinet or the appropriate installation point. After the safety-mat connection cables have been laid, these are connected to the controller. The connection cable is fitted with wire marking and additional colour codes. Clamp on controller Wire No./colour Wire No./colour 1x4 plug 1x4 fixed 3 4 5 6 3/ blue 3/ green 4/ brown 4/ brown 5/ black 5/ yellow The wires labelled 3/4/5 and 6 definately must match clamps 3/4/5 and 6 on the controller to ensure correct functioning. The output contacts of relais K1, N.O. 13/14 or 23/24 must be connected in series with N.O. contacts 33/34 of relais K2 (on the type SSZ-AE-N contacts 11/14 K1 and 21/24 K2) so that a possible fault (sintering by overloading etc.) can be detected. These contacts that are connected in series must now be included in the emergency stop circuit of the machine. As long as the safety-mat is not activated these contacts and therefore the emergency stop circuit is closed. The SSZ-SQ-N and SSZ-SQP-N controller are self locking units. This means that after actuating the safety-mat, the relais remain declined until an acknowledgement has been given via an external potential-free reset button. The reset button is connected to the clamps S1 and S2.