Inverters & Variable Frequency Drives



Similar documents
AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy.

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

WIND TURBINE TECHNOLOGY

AC Induction Motor Slip What It Is And How To Minimize It

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

FRENIC5000MS5 for Machine Tool Spindle Drives

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL

EET272 Worksheet Week 9

FREQUENCY CONTROLLED AC MOTOR DRIVE

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

WHITE PAPER. DC Motors Explained. DC Motors Explained: White Paper, Title Page

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

Application for Small Generator Facility Interconnection Tier 2, Tier 3 or Tier 4 Interconnection

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

Principles of Adjustable Frequency Drives

Physical Address: City: State: Zip Code:

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Variable Frequency Drives and Energy Savings

AMZ-FX Guitar effects. (2007) Mosfet Body Diodes. Accessed 22/12/09.

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

SYNCHRONOUS MACHINES

INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

SECTION VARIABLE FREQUENCY DRIVES

Coordination Control of a Hybrid AC/DC Microgrid With Various Renewable Energy Sources

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE

Energy Systems Integration

Grid integration of renewable energy

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

Speed Control Motors. Speed Control Motors. Brushless Motor's Structure and Principle of Operation H-40. Structure of Brushless Motor

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

SUSTAINABLE TECHNOLOGY

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

Micropower from Tidal Turbines

Motor Fundamentals. DC Motor

Vertical Axis Wind Turbine at WVU Tech. Alex Perry, Tavon Johnson Undergraduate Mechanical Engineering Students

How to Optimize Performance and Minimize Size in High Speed Applications High Performance Brushless DC Motors

Inductance. Motors. Generators

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S

ABB drives. Technical guide No. 4 Guide to variable speed drives

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Lab 14: 3-phase alternator.

Smart Grid and Renewable Energy Grid Integration. Jian Sun, Professor and Director Department of ECSE & Center for Future Energy Systems

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

Understanding Variable Speed Drives

EFC Frequency converters

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Power Quality Paper #3

Lecture 4 Energy Conversion in Wind Turbine

Small Coreless DC Motors

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile

EssPro Energy Storage Grid Substation The power to control energy

VLT AutomationDrive for Marine winch applications

Innovative Medium-Speed Drivetrain Design Program and Dynamometer Testing

Siemens Standard Drives. Application Handbook

Discover the power of e-learning! The Quick Guide to AC Variable Frequency

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

Synchronous motor. Type. Non-excited motors

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Product Data Bulletin

8 Speed control of Induction Machines

Motors and Generators

Principles and Working of DC and AC machines

Solar Power Plant Design and Interconnection

Contractors Guide Central Inverter System Installation

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Offshore Platform Powered With New Electrical Motor Drive System

LOSSELESS STARTING METHOD FOR THE WOUND ROTOR INDUCTION MOTOR

Advantages of 6-Pulse VFD with Lineator AUHF vs Active Front End (AFE) Drives

Electrical Engineering

Passion for Offshore. Wind Power & Renewables Division Market Unit Offshore

BMD. Permanent Magnet AC Synchronous Motors

PowerFlex Dynamic Braking Resistor Calculator

What Is Regeneration?

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

Haliade 150-6MW Experiencia funcional con la nueva generación offshore

PI734D - Technical Data Sheet

GE Power & Water Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY.

PI734B - Technical Data Sheet

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

SUCCESS EPCOS Capacitors

WIND Power Technology: IMD Integrated Motor Drive

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

A1000 Cheat Sheet (Open Loop Vector)

Alternative and Renewable Energy Systems

VARIABLE FREQUENCY DRIVES THEORY, APPLICATION, AND TROUBLESHOOTING

TOSVERT VF-MB1. Functions for lift application

Cree PV Inverter Tops 1kW/kg with All-SiC Design

vacon ac drives for mining & minerals

Application Information

Advance Electronic Load Controller for Micro Hydro Power Plant

SFC Start-up inverter of gas turbo-sets Integrated compact units

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Contactless Power Transfer : Inductive charging of EV

Transcription:

Inverters & Variable Frequency Drives NREL / NWTC 5 MW Dynamometer Rob Wills, Intergrid, LLC Temple, NH, rwills @ intergrid.us 603-801-4749 1

About the Presenter.. Renewable Energy since 1982 Codes and Standards Power Electronics & Inverters Chairing NEC & IEEE WGs on Microgrids NREL - Silicon Carbide-Based Inverters for Intermediate Wind Applications Single & Three Phase Inverters 20-50 kw for Wind and Storage. Variable Speed Drives (VFD) as active front-end. Acknowledgement & Thanks NREL Subcontract - NFC-5-52012-03 CIP Program 2

What is a VFD (Variable Frequency Drive)? A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variablespeed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage. https://en.wikipedia.org/wiki/variable-frequency_drive ABB (Finland) Hitachi (Japan) Yaskawa (Japan) Owns Solectria USA 3

What is a VFD (Variable Frequency Drive)? 4

What is a VFD (Variable Frequency Drive)? Three Phase Rectifier Three Phase Inverter 5

What is a VFD (Variable Frequency Drive)? We use the VFD output inverter as an active PFC rectifier Three Phase Rectifier Three Phase Inverter 6

Why Use VFDs for The Wind Drive Train? 1. Torque Control Torque control is essential for VAWTs Rotor inertia smooths out torque ripple in hub and drive Torque control benefits stall controlled HAWTs Provides more accurate speed control 7

Why Use VFDs? 2. UL Listed Turbine Front End & Assemblies VFDs: UL 508C -> UL 61800-5-1 (2012) Assemblies: UL508 UL 508 Certified Assemblers IEC 61800-5-1 specifies requirements for adjustable speed power drive systems, or their elements, with respect to electrical, thermal and energy safety considerations. It does not cover the driven equipment except for interface requirements. 8

Why Use VFDs? 3. DC Injection Braking DC Injection Braking may eliminate the need for a diversion load http://machinedesign.com/mechanicaldrives/three-phase-induction-motors-putbrakes 9

Why Use VFDs? 4. Ability to use Induction Generators Off The Shelf (OTS) Lower Cost Higher Efficiency - Lower Iron Losses (B ~ Torque) Simple Construction No Magnet Thermal Issues No Cogging VFD supplies required reactive power excitation 10

5. Increased Efficiency Why Use VFDs? Non-Sinusoidal Current causes Higher generator and wiring losses (P = I 2 R) Improvements of a few % to 10% possible with long cables Also, 460V class generators and drives can be used (700V output). Reduces currents and wire size 11

Why Use VFDs? 6. Integral or Optional Diversion Load Control Considering development costs, a VFD is likely less expensive than a custom rectifier and diversion load controller 12

Why Use VFDs? 7. Internal Programming Complex control programs can be embedded in the VFD. For example, startup and shutdown sequences, Torque curve programming (T ~ RPM 2 ) 13

8. Cost Why Use VFDs? Considering development costs, a VFD is likely less expensive than a custom rectifier and diversion load controller 14

What s the Downside? VFD flexibility means lots of setup parameters, complexity and a significant learning curve (500 page software manual) Manufacturers show little interest in low-volume non-traditional applications Field support staff require education 15

Regenerative VFDs Currently, Siemens is the only MFR with a UL1741 listed regen drive. (120 kw three phase). No interest in single phase. 16

Using A Separate Inverter Inverter runs with constant input bus voltage VFD rectifies and boosts input alternator voltage to bus voltage Power output is proportional to VFD torque command No VFD-to-Inverter comm. needed. 17

Intergrid SiC Inverter Development Addressing 25 40 kw Single Phase Market (120/240V) Up to 100 kw 480V three phase Suitable for Battery Energy Storage High Rate LiTi Diversion Load CREE SIC FET Breadboard Prototype Acknowledgement & Thanks NREL Subcontract - NFC-5-52012-03 18

Contact: Dr. Rob Wills, PE Intergrid PO Box 48 Temple, NH 03084 603-801-4749 rwills @ intergrid.us Allan Villiers, 1929 Christmas is coming.. PortandStarboard.com 19