Detcon Model Series 700



Similar documents
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Engineering Specifications XNX Universal Transmitter

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

Ultima X Series Gas Monitors

Application Requirement

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

sierra monitor corporation Fire and Gas Detection Systems

Lockout Specification BW Clip Maintenance-free single gas detector

ALTAIR 5X Multigas Detector Bid Specification

TABLE OF CONTENT

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

EXPLORER 4 MULTIPOINT

Buckeye Detection Systems Fixed Detection Systems Application Survey

ABSTRACT INTRODUCTION

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Global Gas Detection and Monitoring Solutions

MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries

Sieger Searchpoint Optima Plus

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Gas and flame detection Stack gas and dust analysis

How To Use An Irius Pid Detector

The Ambient Air Monitoring System

PortaSens ll G AS DETECTOR

Detcon Model 1000 H 2 S Process Analyzer - Electrochemical Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

An easy and flexible way to do gas detection.

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

Technical data sheet TDS0070

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

COMBIMASS. Technical Data COMBIMASS eco-bio +

with Electronic Assistant

Thermal Mass Flow Meter (Series MST)

SMS GSM Alarm Messenger

Online Infrared Flue Gas Analyzer Gasboard 3000

MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

Honeywell Analytics Lines of Business

Microcor Wireless Transmitter (MWT)

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

SEC 1500 Gas Detector Instruction Manual

Power Supplies 3. SDN-P DIN Rail Series

Automotive Air Quality Sensors: industrial innovations to protect people s health

Analytical Instruments Smart Analyzer 90 Type SMA

The. Hoffer Collection. Perfecting Measurement " A powerful source of Turbine Flowmeters and Electronics for a wide range of flow applications.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PIEZOMETER AIRFLOW MEASURING RING

Triple Waveband Infra-Red Flame Detection

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Natural gas chromatograph LNG gas quality testing

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Rosemount 333 HART Tri-Loop

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

Thermatel Model TA1 Mass Flow Transmitter

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

S-series Mass Connection Solutions

RAEGuard EC FGM-13XX

How to Select a Flame Detector

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Carbon Monoxide (CO) Gas Detection and Control System

3500/62 Process Variable Monitor

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Core Product Guide Gas Leak Detection Solutions for all your building needs

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Product Guide. Total Solution Provider for Gas and Flame Detection. Because every life has a purpose...

Electronic Flow Switches

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Rosemount 751 Field Signal Indicator

Touchpoint Pro. Flexible Gas Control System

M-series FOUNDATION Fieldbus I/O

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

EX-5175-EC Sensor/Transmitter Manual

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

RECON-4 Portable Multi-gas Detector Software Manual

EX 2000/EX 2000 C/ GD 2000/GDP

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

G4 Digital DC Output Modules. G4 Digital DC Output Modules. Features. Description. Part Numbers

Regards from the Team at Rheology Solutions.

Gas sensors for greenhouse measurements

Transcription:

Detcon Model Series 700 GAS DETECTORS Catalog #700-0814 Removing the Environmental Equation from your Gas Detection Decisions 316 SS Construction Encapsulated Electronics Water-Proof Vibration-Proof Corrosion-Proof Multi-Layer Surge Protection Preemptive Fault Diagnostics detcon inc. www.detcon.com GF-00005A-EN 010814

Model Series 700 Gas Detectors Description Detcon Model Series 700 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% encapsulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The gas detector sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Model Series 700 intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output. It is becoming increasingly important that safety systems meet the Safety Integrity Level (SIL) requirements of IEC 61508 and IEC 61511. The SIL rating can only be determined by considering the complete safety system. The Detcon 700 series sensor modules are designed with this in mind and feature a new and unmatched level of pre-emptive fault diagnostics. Application variables like input voltage range, operating temperature range, maintenance schedule, detector reliability and output integrity are all monitored and reported via the 4-20 ma and RS-485 serial output. As a component of a SIL rated system, the Safe Failure Fraction (SFF) of Detcon Model Series 700 sensors are designed to meet the requirements for any SIL 2 rated system. Model Series 700 sensors utilize six distinctive gas detection technologies to satisfy a wide range of industrial applications that require monitoring of oxygen, toxic and flammable gases. Sensors for Hydrogen Sulfide CHEMFET MOS Solid State Technology Harsh and Extreme Locations Wide Temperature & Humidity Range 10-year Sensor Warranty Electrochemical Technology Quick Response Time Long Term Calibration Stability Low Power Consumption Sensors for Combustible Gas Catalytic Technology Non-selective Combustible Gas Detector 3 to 5 Year Life Expectancy Rugged Construction Infrared Technology Combustible Hydrocarbon Gas Detector 5-Year Warranty Miniature Plug-in Optical Detector Sensors for Toxic Gases Oxygen Sensors Electrochemical Technology Quick Response Time Long Term Calibration Stability Low Power Consumption Electrochemical Technology Quick Response Time Embedded Temperature Compensation 2-year Sensor Warranty CO2 Sensors Photo Ionization Universal Non-Selective VOC Sensor Miniature Plug-in Detector Infrared Technology CO2 Gas Detector 5-Year Warranty Miniature Plug-in Optical Detector

Anatomy of a Model Series 700 Junction Box Surge Protection Termination RS-485 Modbus serial output Power 11.5-28 VDC 4-20 ma output 3/4" NPT Thread Fully Encapsulated Circuitry Eliminates failures due to water ingress, corrosion, and vibration Microprocessor Controlled Circuitry With advanced level of I/O protection Corrosion Resistant Electropolished 316SS sensor housing Viewing Lens and Display Scrolling alpha-numeric LED display. Displays reading, status, and supports user interface Internal Magnetic Programming Non-intrusive and simplified operator interface via handheld magnet. Plug-in Replaceable Gas Sensors Catalytic Bead, IR, Solid State H2S, Electrochemical, O2, PID Corrosion-Resistant Lower Housing Electropolished 316 SS threaded housing for quick release. Harsh Environment Splashguard Integral Calibration Port

Technology Features Environmentally Bulletproof Electropolished 316SS Construction 100% Encapsulated Circuitry Bullet-Proof I/O Protection Over-voltage Miswiring EMI/RFI Immunity Water-Proof, Corrosion-Proof, Vibration-Proof Gold Plated Mating Pins Modular and Serviceable Modular Design Plug and Play Components Minimal Spare Parts Universal Design Concept Quick Thread Release For Sensor Replacement Integral Calibration Port Main Housing Lower Housing Plug-in Sensor Splashguard Failsafe User-Friendly Interface LED Display With Antiglare Cover Full Text Display Method Non-intrusive Interface Scrolling Full Message/Text Display PGM1 PGM2 ZERO SPAN Pre-emptive Fault Diagnostics input voltage range Auto Zero/Auto Span Sequence 0% operating temperature Range Detector signal amplitude output signal loop integrity Autospan RS-485 reminder Output RS-485 Output & ma Output Auto zero zero complete auto span apply 50% LEL span ok sensor life 100% remove gas span complete

Installation & Integration Options Model Series 700 gas detectors provide the end-user with a wide variety of output & integration options. The standard intelligent sensor module features an industry standard 4-20 ma output and a RS-485 MODBUS RTU interface. These outputs can be used simultaneously. Additional integration options include a Remote Sensor/Alarm Relay, Wireless Interface and communication interface modules for HART, and Foundation Fieldbus. Shown below are some typical system integration approaches: 4-20 ma, Remote Model Sensor 410-N1 Separation & Local Model 612-N1 4-20 ma Remote Sensor Separation Detcon Alarm Station Local Serial Input Model X40 RS-485 Detcon Alarm Station High Density System - 4-20 ma or Serial Model MCX-32 Distributed I/O Controller RS-232, RS-485, Ethernet 4-20 ma Detcon Alarm Station RS-485 HMI Wide Range DCS/DAS and Integration Options Remote Control Alarm Relay Hart RAM Hart Bridge Foundation Fieldbus Wireless Interface

Ordering Information Combustible Gas Sensor (matched pair catalytic bead) FP-700 Combustible Gas 0-100 % LEL -40 C to +75 C 2 Years Hydrogen Sulfide Gas Sensor (solid state metal oxide semiconductor) TP-700 Hydrogen Sulfide/H2S 0-100 ppm -40 C to +75 C 10 Year conditional Oxygen Gas Sensor (galvanic metal air battery) DM-700-O2 Oxygen/O2 0-25 % -20 C to +50 C 2 Years Combustible Hydrocarbon & Carbon Dioxide Gas Sensors (non-dispersive infrared optical - NDIR) IR-700-CH Combustible Hydrocarbons 0-100 % LEL -40 C to +75 C 5 Years pro-rated IR-700-CO2 Carbon Dioxide/CO2 0-3 % -40 C to +75 C 5 Years pro-rated Volatile Organic Compound (VOC) Gas Sensors (photo ionization detector - PID) PI-700-VOC Volatile Organic Compounds 0-10 ppm -20 C to +50 C 6 Months PI-701-VOC Volatile Organic Compounds 0-1,000 ppm -20 C to +50 C 6 Months Toxic Gas Sensors (electrochemical fuel cell) DM-700-C2H2 Acetylene/C2H2 0-100 ppm 20 C to +50 C 2 Years DM-700-NH3 Ammonia/NH3 0-100 ppm 20 C to +40 C 2 Years DM-700-AsH3 Arsine/AsH3 0-1 ppm 20 C to +40 C 1 1/2 Years DM-700-Br2 Bromine/Br2 0-5 ppm 20 C to +50 C 2 Years DM-700-C4H6 Butadiene/C4H6 0-100 ppm 20 C to +50 C 2 Years DM-700-CO Carbon Monoxide/CO 0-100 ppm 40 C to +50 C 3 Years DM-700-Cl2 Chlorine/Cl2 0-10 ppm 20 C to +50 C 2 Years DM-701-ClO2 Chlorine Dioxide/ClO2 0-1 ppm 20 C to +50 C 2 Years DM-700-B2H6 Diborane/B2H6 0-5 ppm 20 C to +40 C 1 1/2 Years DM-700-C2H5OH Ethanol/C2H5OH 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H5SH Ethyl Mercaptan/C2H5SH 0-100 ppm 40 C to +50 C 2 Years DM-700-C2H4 Ethylene/C2H4 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H4O Ethylene Oxide/C2H4O 0-100 ppm 20 C to +50 C 2 Years DM-700-F2 Fluorine/F2 0-1 ppm 10 C to +40 C 1 1/2 Years DM-700-CH2O Formaldehyde/CH2O 0-100 ppm 20 C to +50 C 2 Years DM-700-GeH4 Germane/GeH4 0-2 ppm 20 C to +40 C 1 1/2 Years DM-700-N2H4 Hydrazine/N2H4 0-1 ppm 10 C to +40 C 1 Year DM-700-H2 Hydrogen/H2 0-100 ppm 20 C to +50 C 2 Years DM-701-H2 Hydrogen/H2 LEL 40 C to +40 C 2 Years DM-702-H2 Hydrogen/H2 0-1% 40 C to +40 C 2 Years DM-700-HBr Hydrogen Bromide/HBr 0-30 ppm 20 C to +40 C 1 1/2 Years DM-700-HCl Hydrogen Chloride/HCl 0-30 ppm 20 C to +40 C 1 1/2 Years DM-700-HCN Hydrogen Cyanide/HCN 0-30 ppm 40 C to +40 C 2 Years DM-700-HF Hydrogen Fluoride/HF 0-10 ppm 20 C to +35 C 1 Years DM-700-H2S Hydrogen Sulfide/H2S 0-100 ppm 40 C to +50 C 2 Years DM-700-CH3OH Methanol/CH3OH 0-100 ppm 20 C to +50 C 2 Years DM-700-CH3SH Methyl Mercaptan/CH3SH 0-100 ppm 40 C to +50 C 2 Years DM-700-NO Nitric Oxide/NO 0-100 ppm 20 C to +50 C 3 Years DM-700-NO2 Nitrogen Dioxide/NO2 0-10 ppm 20 C to +50 C 2 Years DM-700-O3 Ozone/O3 0-1 ppm 10 C to +40 C 2 Years DM-700-PH3 Phosphine/PH3 0-5 ppm 20 C to +40 C 1 1/2 Years DM-700-SiH4 Silane/SiH4 0-50 ppm 20 C to +40 C 1 1/2 Years DM-700-SO2 Sulfur Dioxide/SO2 0-20 ppm 20 C to +50 C 2 Years Accessories Description Remote Control/Alarm Relay in NEMA 7 Junction Box (Aluminum or Stainless Steel) Hart RAM in NEMA 7 Junction Box (Aluminum or Stainless Steel) Hart Bridge in NEMA 7 Junction Box (Aluminum or Stainless Steel) Foundation Fieldbus in NEMA 7 Junction Box (Aluminum or Stainless Steel) Wireless Interface in NEMA 7 Junction Box (Aluminum or Stainless Steel) *Standard Range - contact factory for other ranges. **Replaceable plug-in sensor. Contact the factory for other gases not on this list. Cross sensitivity data available on request. Specifications Common Specifications Input Voltage 11.5-28 VDC standard Power Consumption <2 watts typical Outputs Linear 4-20 ma DC RS-485 Modbus -RTU Electrical Classification Explosion Proof FP-700, TP-700, IR-700-CH, IR-700-CO2: Class I, Division 1, Groups B, C, D Class I, Zone 1, Group IIB+H2 (ATEX) DM-700 Toxics, DM-700-O2, PI-700: Class I, Division 1, Groups A, B, C, D Class I, Zone 1, Group IIC (ATEX) Safety Approvals CSA/NRTL (US OSHA Certified) ATEX GOST INMETRO CNEX PESO ABS Dimensions 7" High x 2 1/8" Diameter (sensor only) Weight 2 Lbs Functional Safety Rating IEC 61508 SIL2 Certified (IR, TP, FP, DM) Exida assessed SIL2 (FMEDA) Performance Approvals IR-700, FP-700 to ISA 12.13, CSA #152 TP-700, DM-700 to ISA 92.0.01 Technology Specifications Accuracy/Repeatability FP-700: ±3% 0-50% LEL; ±5% 50-100% TP-700: ±10% of reading or ±2 ppm (greater of) DM-700-O2: ±2% full scale IR-700-CH: ±2% F.S. (0-50% LEL) IR-700-CO2: ±5% full scale PI-700: ±10% of reading; ±2.5% of range (greater of) DM-700 (toxics): ±2% full scale Response/Clearing Time FP-700: T50 <10 seconds; T90 <30 seconds TP-700: T50 <30 seconds; T80 <60 seconds DM-700-O2: T90 <20 seconds IR-700-CH: T50 <10 seconds; T90 <30 seconds IR-700-CO2: T50 <15 seconds; T90 <40 seconds PI-700: T50 <10 seconds; T90 <30 seconds DM-700 (toxics): Contact factory for specific gases Operating Humidity Range (Continuous) FP-700: 0-99% RH non-condensing TP-700: 15-100% RH non-condensing DM-700-O2: 0-99% RH non-condensing IR-700-CH: 0-99% RH non-condensing IR-700-CO2: 0-99% RH non-condensing PI-700: 0-100% non-condensing DM-700 (toxics): typically 10-90% RH contact factory for specific gases Warranty Detcon Inc. warrants each new Model 700 Intelligent Transmitter to be free from defects in material and workmanship under intended normal use for a period of two years from the date of shipment to the original purchaser. Detcon warrants each new plug-in replaceable sensor to be free from defects in material and workmanship under intended normal use for the period described in the table on the left. All warranties are FOB the Detcon factory located in The Woodlands, Texas, USA.