BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview



Similar documents
Siemens AG Switching Devices. Configuration Manual 10/2010 SENTRON. Answers for infrastructure.

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Technical catalogue. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors

Electronic overload relay EF65, EF96 and EF146

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM9 10(24VDC) Article No.:

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Electronic overload relay EF19 and EF45

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

5SV Residual Current Protective Devices

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

38 Series - Relay interface modules A

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

BETA Protecting SITOR Semiconductor Fuses

ESB and EN installation contactors Application handbook

38 Series - Relay interface modules A

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Switching Devices Contactors and Contactor Assemblies Special Applications

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

ABB i-bus KNX SA/S Switch Actuators Product Manual

Bimetallic Overload Relay Specifications

Residual Current Protective Devices

Manual motor starter MS116

Relés e Contatores de Estado Sólido SIRIUS

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

48 SERIES Relay interface modules 10 A

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

49 Series - Relay interface modules A. Features

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Series 8146/5-V37 and Series 8150/5-V37

Pluggable interface relays CR-P Pcb relays

R.C.C.B. s two-pole LEXIC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technicaldata General

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Three-phase monitoring relay CM-PFE

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MasterINTERFACE 39 Series - Relay interface modules

Thermistor motor protection

ABB i-bus KNX Switch Actuators SA/S Product Information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM4TG20 three-phase network control relay RM4-T - range V

RY2 miniature industrial relays

MasterINTERFACE 39 Series - Relay interface modules

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Safety Relays ESM/ESM-F

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Safety automation solutions

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electric Rotary Actuator - On/Off or programmable control actuator

E-STOP relays, safety gate monitors

D-Line Contactors, Overload Relays and Accessories

How can a charging station for electric vehicles be set up simply and safely?

13 SERIES. Electronic step relays A

PSR The compact range Description

Protection Equipment

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Thyristor-controlled power supplies and battery chargers

15 Series - Electronic step relay and dimmer. Features SERIE

Plug and Socket Devices CES 63 A Series 8579

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

ABB i-bus KNX Switch Actuators SA/S Product Information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermal-Magnetic Circuit Breaker M1-..

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

HERZ-Thermal Actuators

Contact expansion modules

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Vario-Series Accessories

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

mecotron Safety relay ESTOP-2 For emergency stop monitoring

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

E-STOP relays, safety gate monitors

Quick Connect. quick - simple - efficient.

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Digital input modules

Product and functional description

E-STOP relays, safety gate monitors

Transcription:

BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary switches can be mounted without tools. When used with terminal covers, the devices are also sealable. Insta contactors without manual switch They are playing an increasingly significant role in lighting circuits in buildings. Insta contactors are increasingly used in industry for motors where distribution technology plays a major role, e.g. in installations for heat pumps and air conditioning technology. In addition to their basic function, they can also be used to switch single-phase and three-phase electrical motors on and off. Insta contactors with manual switch A key feature of Insta contactors with manual operation is the fact that users can switch consumers/loads on and off by hand. Benefits Extremely long service life of 3 million switching cycles is a testimony to their reliability Switching position indicator for fast recognition of operating state offers greater safety when checking the plant. Safe insertion of conductor through cable entry funnel saves time during installation Insulated right through to the cable entry funnel. This provides enhanced touch protection Auxiliary switches can be retrofitted on all versions even on the type 20 A. More functionality when using the devices. Insta contactors with O/I/Automatic function enable the testing of a plant by manual switch without the need to apply a control voltage. /20 Siemens ET B1 10/200

Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology Technical specifications 1) For NO contacts only. Insta contactors 5TT5 0. 5TT5 2., 5TT5 3. Auxiliary switches 5TT5 4. 5TT5 5. 5TT5 910 Standards IEC 60947-4-1, IEC 60947-5-1, IEC 61095; EN 60947-4-1, EN 60947-5-1, EN 61095, VDE 0660 Approved acc. to VDE 0637 Number of poles 2 4 4 4 2 Rated frequency at AC Hz 50/60 Rated control voltage U c VAC 24, 230 24, 115, 230 24, 230 24, 230 -- Operating range U c 0.5... 1.1 -- Rated operational voltage U e VAC 230 400 230/400 Rated operational current I e A 20 25 40 63 6/4 (230/400 V) Rated power dissipation P v Pick-up power (without manual switch VA/W 6/3. 10/5 15.4/6 -- or manual switch in "I" position) Pick-up power (with manual switch in "AUTO" position) VA/W 12/10 33/25 62/50 -- Holding power VA/W 2./1.2 5.5/1.6 7.7/3 -- Per contact VA 1.7 2.2 4 -- Switching times Closing (NO contacts) ms 15... 25 10... 20 15... 20 -- Opening (NO contacts) ms 20 20 10 -- Closing (NC contacts) ms 20... 30 20... 30 5...10 -- Opening (NC contacts) ms 10 10 10... 15 -- Rated impulse withstand voltage U imp kv 4 Rated insulation voltage U i V 440 500 Contact gap, minimum mm 3.6 3.4 4 Electrical service life At I e and load AC-1/AC-7a For switching 200000 100000 -- cycles AC-3/AC-7b 300000 500000 150000 -- Mechanical service life For switching cycles 3 million Maximum switching frequency At load In switching cycles/h Switching of resistive loads AC-1/AC-7a For rated operational power P s Single-phase 230 V kw 4 5.4.7 13.3 -- Three-phase 400 V kw -- 16 26 40 -- Switching of three-phase asynchronous motors AC-3/AC-7b For rated operational power P s Single-phase 230 V kw 1.3 1) 1.3 3.7 5 -- Three-phase 400 V kw -- 4 11 15 -- Minimum switching capacity V; ma 17; 50 12; 5 Overload withstand capability Per conducting path (NO contacts only) At 10 s A 72 6 176 240 -- Short-circuit protection, acc. to coordination type 1 Back-up fuse characteristic gl/gg A 20 25 63 0 6 Terminals ± screw (Pozidriv) Coil connection 1 1.2 -- Main connection 1 3.5 1 Tightening torques Coil connection Nm 0.6 -- Main connection Nm 1.2 2 0. Conductor cross-sections Coil connection Rigid mm 2 1.0... 2.5 -- Flexible, mm 2 1.0... 2.5 -- with end sleeve Main connection Rigid mm 2 1.0... 10 1...25 1... 2.5 Flexible, with end sleeve mm 2 1.0... 6 1...16 1... 2.5 Permissible ambient temperature For operation C -5... +55 For storage C -30... +0 Degree of protection Acc. to EN 60529 IP20, with connected conductors 600 Siemens ET B1 10/200 /21

BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Selection and ordering data 5TT5 00-0 5TT5 30-0 5TT5 40-0 Version U e I e U c MW DT Order No. Price per PU Insta contactors without manual switch PG PU PS*/ P. unit VAC AAC VAC 1 unit Unit(s) Unit(s) kg Weight per PU approx. For alternating current continuous operation, with switching position indication, with AC magnetic system 2NO 230 20 230 1 } 5TT5 00-0 027 1 1 0.130 24 } 5TT5 00-2 027 1 1 0.130 1NO, 1NC 230 20 230 } 5TT5 01-0 027 1 1 0.130 24 } 5TT5 01-2 027 1 1 0.130 2NC 230 20 230 } 5TT5 02-0 027 1 1 0.130 24 } 5TT5 02-2 027 1 1 0.130 4NO 400 25 230 2 } 5TT5 30-0 027 1 1 0.230 115 B 5TT5 30-1 027 1 1 0.230 24 } 5TT5 30-2 027 1 1 0.230 3NO, 1NC 400 25 230 } 5TT5 31-0 027 1 1 0.230 115 B 5TT5 31-1 027 1 1 0.230 24 B 5TT5 31-2 027 1 1 0.230 4NO For high capacitive loads up to 150 μf 400 25 230 2 B 5TT5 20-0 027 1 1 0.230 2NO, 2NC 400 25 230 } 5TT5 32-0 027 1 1 0.230 24 } 5TT5 32-2 027 1 1 0.230 4NC 400 25 230 } 5TT5 33-0 027 1 1 0.230 24 B 5TT5 33-2 027 1 1 0.230 4NO 400 40 230 3 } 5TT5 40-0 027 1 1 0.30 24 } 5TT5 40-2 027 1 1 0.30 3NO, 1NC 400 40 230 B 5TT5 41-0 027 1 1 0.30 24 B 5TT5 41-2 027 1 1 0.30 2NO, 2NC 400 40 230 B 5TT5 42-0 027 1 1 0.30 24 B 5TT5 42-2 027 1 1 0.30 4NC 400 40 230 } 5TT5 43-0 027 1 1 0.30 24 B 5TT5 43-2 027 1 1 0.30 4NO 400 63 230 3 } 5TT5 50-0 027 1 1 0.30 24 } 5TT5 50-2 027 1 1 0.30 3NO, 1NC 400 63 230 } 5TT5 51-0 027 1 1 0.30 24 B 5TT5 51-2 027 1 1 0.30 2NO, 2NC 400 63 230 B 5TT5 52-0 027 1 1 0.30 24 B 5TT5 52-2 027 1 1 0.30 4NC 400 63 230 } 5TT5 53-0 027 1 1 0.30 24 B 5TT5 53-2 027 1 1 0.30 Auxiliary switches For mounting on right-hand side Max. one auxiliary switch per Insta contactor. 2 NO 230, AC-15 6 -- 0.5 } 5TT5 910-0 027 1 1 0.030 1NO, 1NC 230, AC-15 6 -- } 5TT5 910-1 027 1 1 0.030 5TT5 910-0 Sealable terminal covers For Insta contactor 20 A 1 B 5TT5 910-5 027 1 2 0.002 For Insta contactor 25 A 2 B 5TT5 910-6 027 1 2 0.003 For Insta contactor 40 A and 63 A 3 B 5TT5 910-7 027 1 2 0.004 /22 Siemens ET B1 10/200

Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology Version U e I e U c MW DT Order No. Price per PU PG PU PS*/ P. unit VAC AAC VAC 1 unit Unit(s) Unit(s) kg Insta contactors with manual switch 0/I/Automatic Weight per PU approx. For alternating current continuous operation, with switching position indication, with AC magnetic system 2 NO 230 20 230 1 } 5TT5 00-6 027 1 1 0.135 24 } 5TT5 00-027 1 1 0.135 1 NO, 1 NC 230 20 230 B 5TT5 01-6 027 1 1 0.135 24 B 5TT5 01-027 1 1 0.135 5TT5 00-6 4 NO 400 25 230 2 } 5TT5 30-6 027 1 1 0.235 24 } 5TT5 30-027 1 1 0.235 3 NO, 1 NC 400 25 230 } 5TT5 31-6 027 1 1 0.235 24 B 5TT5 31-027 1 1 0.235 5TT5 30-6 4 NO 400 40 230 3 } 5TT5 40-6 027 1 1 0.3 24 B 5TT5 40-027 1 1 0.3 3 NO, 1 NC 400 40 230 B 5TT5 41-6 027 1 1 0.3 24 B 5TT5 41-027 1 1 0.3 4 NO 400 63 230 } 5TT5 50-6 027 1 1 0.3 5TT5 40-6 Auxiliary switches For mounting on right-hand side Max. one auxiliary switch per Insta contactor. 2 NO 230, AC-15 6 -- 0.5 } 5TT5 910-0 027 1 1 0.030 1 NO, 1 NC 230, AC-15 6 -- } 5TT5 910-1 027 1 1 0.030 Sealable terminal covers For Insta contactor 20 A 1 B 5TT5 910-5 027 1 2 0.002 For Insta contactor 25 A 2 B 5TT5 910-6 027 1 2 0.003 For Insta contactor 40 A and 63 A 3 B 5TT5 910-7 027 1 2 0.004 Siemens ET B1 10/200 /23

BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Dimensional drawings Insta contactors, AC technology Without manual switch I2_1237 I2_123 I2_1239 1 36 54 5TT5 0.-0 5TT5 0.-2 5TT5 20-0 5TT5 3.-0 5TT5 3.-2 5TT5 4.-0 5TT5 4.-2 5TT5 5.-0 5TT5 5.-2 With manual switch 6 4 6 4 I2_1241 I2_1242 I2_1243 1 36 6 4 54 5TT5 0.-6 5TT5 0.- 5TT5 3.-6 5TT5 3.- 5TT5 4.-6 5TT5 4.- 5TT5 5.-6 Auxiliary switches I2_1240 9 44 5TT5 910-0 5TT5 910-1 Schematics A11 3 A11 21 A111 21 A11 3 5 7(13) A1 1 3 5 21 A2 2 4 A2 2 22 A212 22 5TT5 00 5TT5 01 5TT5 02 5TT5 20 5TT5 30 5TT5 40 5TT5 50 A2 2 4 6 (14) A2 2 4 6 22 5TT5 31 5TT5 41 5TT5 51 A113 21 31 43 A214 22 32 44 5TT5 32 5TT5 42 5TT5 52 A111 21 31 41 A212 22 32 42 5TT5 33 5TT5 43 5TT5 53 61 53 62 54 5TT5 910-0 5TT5 910-1 /24 Siemens ET B1 10/200

Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology More information Mounting position, Insta contactors, AC technology The installation of the devices is permissible in the positions shown in the following diagram (0 to, 270 to 0 ). There are no restrictions when the devices are installed in these normal mounting positions. 10 Manual switching with O/I/Automatic function The versions 5TT5...-6 and 5TT5...- are also fitted with a manual switch. The knob allows preselection of 3 positions: Knob in the "AUTO" position Automatic mode normal protective function Knob in the "I" position Continuous operation switched on manually (without control signal, when a control signal is applied, the manual switch on reset, i.e. the knob is automatically reset to the "AUTO" position). Knob in the "O" position Off switched off (coil circuit interrupted) 270 0 I2_1236b Heat dissipation If several Insta contactors with AC magnetic system are mounted in series in a distribution board, there are no restrictions for the types 25 A, 40 A and 63 A within the permissible ambient temperature range up to 55 C. For 20 A types within the temperature range up to 40 C, a 5TG 240 spacer must be installed after every third Insta contactor, and in the temperature range over 40 C to 55 C, after every second contactor. Plant test without applying a control voltage Insta contactors with O/I/Automatic function enable the testing of a plant by manual switch without the need to apply a control voltage. Automatic by control signal When applying a control signal to the terminals A1 and A2, the Insta contactors can be reset from continuous operation mode ("I" position) to automatic mode ("AUTO" position). Siemens ET B1 10/200 /25

BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Switching of AC voltages DC-1 Permissible DC switching currents for NO contacts with resistive load 1 contact 2 contacts in series 3contacts in series 5TT5 0 2-pole, 20 A I e for U e =24V DC A 20 20 -- -- U e =110V DC A 6 10 -- -- U e =220V DC A 0.6 6 -- -- 5TT5 2, 5TT5 3 4-pole, 25 A I e for U e =24V DC A 25 25 25 25 U e =110V DC A 6 10 20 20 U e =220V DC A 0.6 6 15 15 5TT5 4 4-pole, 40 A I e for U e =24V DC A 40 40 40 40 U e =110V DC A 4 10 30 40 U e =220V DC A 1.2 20 40 5TT5 5 4-pole, 63 A I e for U e =24V DC A 63 63 63 63 U e =110V DC A 4 10 35 63 U e =220V DC A 1.2 30 63 4 contacts in series Switching of lamps Incandescent lamp loads, lamp type 1000 W 500 W 200 W 100 W 60 W 5TT5 0, 2-pole 20 A Per NO/NC contact 1 3 10 20 33 5TT5 2, 4-pole 25 A Per NO/NC contact 2 4 10 20 33 5TT5 3, 4-pole 25 A Per NO/NC contact 1 3 10 20 33 5TT5 4, 4-pole 40 A Per NO/NC contact 4 20 40 65 5TT5 5, 4-pole 63 A Per NO/NC contact 5 10 25 50 5 Maximum number of lamps in units, per NO/NC contact at 230 V AC, 50 Hz. Fluorescent and compact lamps in ballast operation (KVG) Uncorrected Parallel-corrected DUO switching, 2-lamp Lamp type W L1 L36 L5 L1 L36 L5 2 L1 2 L36 2 L5 Capacitor capacitance μf -- -- -- 4.5 4.5 7.0 -- -- -- 5TT5 0, 2-pole 20 A Per NO/NC contact 22 17 14 7 7 4 30 17 10 5TT5 2, 4-pole 25 A Per NO/NC contact 41 41 2 33 33 21 54 36 19 5TT5 3, 4-pole 25 A Per NO/NC contact 24 20 17 5 40 24 14 5TT5 4, 4-pole 40 A Per NO/NC contact 65 4 4 31 100 65 40 5TT5 5, 4-pole 63 A Per NO/NC contact 140 95 70 73 73 47 150 95 60 Fluorescent and compact lamps with electronic primary switching device (ECG) 1 lamp 2 lamps Lamp type W 1 L1 1 L36 1 L5 2 L1 2 L36 2 L5 5TT5 0, 2-pole 20 A Per NO/NC contact 25 15 14 12 7 7 5TT5 2, 4-pole 25 A Per NO/NC contact 35 20 19 17 10 9 5TT5 3, 4-pole 25 A Per NO/NC contact 35 20 19 17 10 9 5TT5 4, 4-pole 40 A Per NO/NC contact 100 52 50 50 26 25 5TT5 5, 4-pole 63 A Per NO/NC contact 140 75 72 70 3 36 High-pressure mercury-vapor lamps (HQL) (permissible number of lamps in units per NO contact/nc contact at 230 V AC, 50 Hz) Uncorrected Parallel-corrected Lamp type W 50 0 125 250 400 700 1000 50 0 125 250 400 700 1000 Capacitor capacitance μf -- -- -- -- -- -- -- 7 10 1 25 60 5TT5 0, 2-pole 20 A Per NO/NC contact 14 10 7 4 2 1 1 4 4 3 1 1 0 0 5TT5 2, 4-pole 25 A Per NO/NC contact 1 13 9 5 3 2 1 21 1 15 6 3 2 5TT5 3, 4-pole 25 A Per NO/NC contact 1 13 9 5 3 2 1 5 5 4 2 1 0 0 5TT5 4, 4-pole 40 A Per NO/NC contact 3 29 20 10 7 4 3 31 27 22 12 9 5 4 5TT5 5, 4-pole 63 A Per NO/NC contact 55 42 29 15 10 6 4 47 41 33 1 13 7 5 Halogen metal-vapor lamps (HQI) Uncorrected Parallel-corrected With electronic ballast PCI Lamp type W 70 150 250 400 1000 2000 70 150 250 400 1000 2000 20 35 70 150 Capacitor capacitance μf -- -- -- -- -- -- 12 20 33 35 95 14 -- -- -- -- 5TT5 0, 2-pole 20 A Per NO/NC contact 10 5 3 3 1 0 2 1 0 0 0 0 9 6 5 4 5TT5 2, 4-pole 25 A Per NO/NC contact 12 7 4 3 1 0 12 7 4 4 1 1 9 6 5 4 5TT5 3, 4-pole 25 A Per NO/NC contact 12 7 4 3 1 0 3 1 1 0 0 0 9 6 5 4 5TT5 4, 4-pole 40 A Per NO/NC contact 23 12 7 6 2 1 1 11 6 6 2 1 1 11 10 5TT5 5, 4-pole 63 A Per NO/NC contact 32 1 10 9 3 1 25 15 9 3 2 20 13 12 10 /26 Siemens ET B1 10/200

Siemens AG 200 BETA Switching 5TT5 Insta contactors, AC technology High-pressure sodium-vapor lamps (NAV) Uncorrected Parallel-corrected With electronic ballast PCI Lamp type W 150 250 400 1000 150 250 400 1000 20 35 70 150 Capacitor capacitance μf -- -- -- -- 20 33 4 106 -- -- -- -- 5TT5 0, 2-pole 20 A Per NO/NC contact 5 3 2 0 1 0 0 0 9 6 5 4 5TT5 2, 4-pole 25 A Per NO/NC contact 6 4 2 1 7 4 3 1 9 6 5 4 5TT5 3, 4-pole 25 A Per NO/NC contact 6 4 2 1 1 1 0 0 9 6 5 4 5TT5 4, 4-pole 40 A Per NO/NC contact 17 10 6 3 11 6 4 2 1 11 10 5TT5 5, 4-pole 63 A Per NO/NC contact 22 13 3 16 10 6 3 20 13 12 12 High-pressure sodium-vapor lamps Uncorrected Parallel-corrected Lamp type W 1 35 55 135 10 1 35 55 135 10 Capacitor capacitance μf -- -- -- -- -- -- 5 20 20 26 40 5TT5 0, 2-pole 20 A Per NO/NC contact 22 7 7 4 3 3 6 1 1 1 -- -- 5TT5 2, 4-pole 25 A Per NO/NC contact 27 9 9 5 4 4 30 7 7 5 3 3 5TT5 3, 4-pole 25 A Per NO/NC contact 27 9 9 5 4 4 7 1 1 1 -- -- 5TT5 4, 4-pole 40 A Per NO/NC contact 71 23 23 14 10 10 44 11 11 4 5 5TT5 5, 4-pole 63 A Per NO/NC contact 30 30 19 13 13 66 16 16 12 7 Fluorescent Lumilux lamps T5 type FC, with electronic ballast (ECG) 1 lamp 2 lamps Lamp type W 22 40 55 2 22 2 40 2 55 5TT5 0, 2-pole 20 A Per NO/NC contact 22 12 11 6 4 5TT5 2, 4-pole 25 A Per NO/NC contact 30 15 12 15 7 6 5TT5 3, 4-pole 25 A Per NO/NC contact 30 15 12 15 7 6 5TT5 4, 4-pole 40 A Per NO/NC contact 0 40 30 40 20 15 5TT5 5, 4-pole 63 A Per NO/NC contact 110 60 55 30 22 Fluorescent Lumilux lamps T5 type HE, with electronic ballast (ECG) 1 lamp 2 lamps Lamp type W 14 21 2 35 2 14 2 21 2 2 2 35 5TT5 0, 2-pole 20 A Per NO/NC contact 30 22 1 14 15 11 9 7 5TT5 2, 4-pole 25 A Per NO/NC contact 40 30 22 1 20 15 11 9 5TT5 3, 4-pole 25 A Per NO/NC contact 40 30 22 1 20 15 11 9 5TT5 4, 4-pole 40 A Per NO/NC contact 105 0 60 4 52 40 30 24 5TT5 5, 4-pole 63 A Per NO/NC contact 150 115 70 75 57 35 Fluorescent Lumilux lamps T5 type HO, with electronic ballast (ECG) 1 lamp 2 lamps Lamp type W 24 39 49 54 0 2 24 2 39 2 49 2 54 2 0 5TT5 0, 2-pole 20 A Per NO/NC contact 20 12 10 9 6 10 6 5 4 3 5TT5 2, 4-pole 25 A Per NO/NC contact 26 16 14 13 13 7 6 4 5TT5 3, 4-pole 25 A Per NO/NC contact 26 16 14 13 13 7 6 4 5TT5 4, 4-pole 40 A Per NO/NC contact 70 42 35 32 22 35 21 17 16 11 5TT5 5, 4-pole 63 A Per NO/NC contact 100 62 52 47 32 50 31 26 23 16 Siemens ET B1 10/200 /27