FC18 Controller(Interlocking) Product Manual



Similar documents
Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

FIREDEX Conventional Fire Panels

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Contents. Document information

Drayton Digistat +2RF/+3RF

Duct Humidity Transmitter

User manual Rev 1.3 Contents

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Digital input modules

GST301. (Single Protection Zone) Operation Manual

Installation and Operation Manual

ZC-24DO CANopen I/O Module: 24 Digital Outputs

User s Manual Before using the inverter, you need to read and save the safety instructions.

Modular I/O System Analog and Digital Interface Modules

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Installation Handbook. Interactive Fire Alarm System Release 3. Repeater Panel BU-320 / Information Panel BV-320

Notice. Reverse engineering and disassembly are prohibited.

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

GSM Autodialer Professional GJD700 Speech & Text Autodialer

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

DC Electronic Loads 8500 series

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Operation and Installation Manual

Input module, input/output module

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Features, Benefits, and Operation

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

T7560A,B,C Digital Wall Module

VEGA Analogue Addressable Control Panels

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Wahl C50 Calibrator FEATURES

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

E E V R E - R S - O S L O A L R

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

LIEBERT VNSA Installation Sheet

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

NC-12 Modbus Application

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

User Manual. Before installation and use, please read the user manual carefully.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Radiant Temperature Sensor TY7321

Installation manual. Version

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

User Guide. Model Insulation Tester / Megohmmeter


e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

PD 100A. Printing data system

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

TS93 EMR T/PT/TDE. Surface applied door closer

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

T0118 T2118 T3118. Instruction Manual

Repeaters and Mimics Data Sheet

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

T Zone Weekly Timer

GSM Voice Auto Dialer & SMS Sender JC-999

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Electronic Control Devices The European Product Catalogue 2007

16/32 Channel 1U Rack Mount CCTV Power Supply

TrueAlarm Fire Alarm Systems

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

12 Volt 30 Amp Digital Solar Charge Controller

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

HM-W536 Install Guide

Electronic Control Devices The European Product Catalogue 2007

PowerLogic Sub Meter Display (SMD and SMDOPN)

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

MechoNet TM Network Interface (MNI) Specification Submittal

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

User Guide. 4 wire Earth Resistance Tester Model GRT300

V350-R34 V350J-R34. npn inputs pnp inputs

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

2013 Wireless Video Intercom INSTALLATION GUIDE

Life Alarm Fire Alarm Controls

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

OZW30. Central Unit SYNERGYR

Digital Keypad Use s Manual

Transcription:

Controller(Interlocking) Product Manual 20 controller with 1 line card, max. 252 points 40 controller with 2 line card, max. 504 points Characteristic Multi-language operation menu designed with Windows-like style for fast and easy operation. Shortcut key (right key) for popping out operation items of equipment/event. Large history storage size for up to 10000 records, first in first out order, all events can be recorded during the operation period. LCD backlight Auto-off mode. When no operation or message to display within preset time, LCD backlight will be automatically turn off. When there are events / operations, LCD will light up automatically to display events and/or interlock devices. 2 channels of programmable input/output (Output: 40mA@24VDC, it can be programmed as general alarm output or general trouble output; Input: dry contact). 1 channel of NAC for audible and visible devices (max. 0.5A @24VDC). 8 channels of interlocking functions for automatic control and manual operations of control equipments. Efficient group programming according to different usage. 20 controller can connect up to 252 points, 40 controller can connect up to 504 points. Up to 32 controllers can be networked together with 20 and 40. Controller network bus (-BUS) has a max. distance of 1000m. Twisted paired cable is for polarity-free detection bus (FD18-BUS), max. loop distances is up to 2,500m, and max. stub distance is up to 1,500m. (the wiring capacity is between 1.0 to 1.5 mm2 ) Three user levels for different operation authority. Each user level is accessed by a pre-defined and changeable password. Convenient pluggable terminals with clear marks for field wiring. Fire safety and security products

Auto-mapping function to support on commissioning task. Detection algorithm can be adjusted from controller according to different environment, to provide high reliability of alarm and reduce false alarm. Programming can be done either directly on controller or through computer. Sticker Method easy for commissioning on site. Structure Pinter Terminal board b d Power l Line card 2 Line card 1 Keyboard 1 Main board LED screen Battery CPU board Keyboard 2 Fig. 1 Internal structure Interlocking l Operation Panel Fig. 2 Front overview No. Name 1. LCD 2. Printer 3. Keyboard 4. Indicators and keys 5. Interlocking 2 A6V10281972cen-- Fire safety and security products 07.2012

Installation Fig.3 Installation size (in:mm) Installation must comply with the local regulation! 1. Ensure the wall is dry, clean, flat and firm in which the controller is installed. 2. Chose a proper installation location to make sure the front door can be opened smoothly. 3. Mark the drillings for 4 installation holes on the wall. (Fig. 2-1) 4. Drill the holes, put expansion bolts in and insert the M6 screws. 5. Break the cable entries on the controller. 6. Hang the controller over those screws. 7. Insert cables into the controller. 8. Open the front panel and tighten the screws to fix the controller on the wall. 9. Connect cables to the terminals according to Fig. 4, 5, 6, 7, 8, 9. 10. Install and secure the batteries properly. 11. Close the front panel. Lock it with special tools and store the tools in safe place. Connection To Line 1 BP1 BS1 To Field device AP1 AS1 To Field device Note: In loop mode, wires from BP1 must end at AP1; wires from BS1 must end at AS1. The connection of field devices (except FDCL181 isolator) is polarity free. Fig. 4 Line card connection diagram (the same for Line 2) To FRT FT1810 FTL CAN- FTH CAN Fig. 5 FRT connection diagram 3 A6V10281972cen-- Fire safety and security products 07.2012

To Controller FCH FCL To Controller FCH FCL To Controller Note: Ensure positive and negative connections are properly in place, -Bus is polarity sensitive. Connect a 120Ω resistor as monitoring resistor. It must be connected to the end of the line. ( It can be set by the two-digit Dip-switch on the main board, see Dip-switch connection configuration ) Fig. 6 Network connection diagram NAC-EOL- To NAC Red NAC Orange NAC- 20K resistor Visible and audible device Fig. 7 NAC connection diagram To Input/Output IO IO-EOL- Red Orange 1K 10K Dry Contact IO- Output Fig. 8 Main board input/output connection diagram Input To Int. Chan. 1 KI1 IO-EOL- Red Orange 1K Dry Contact 10K KC1 KO1 Output(40mA@24VDC) Fig. 9 Interlocking panel connection diagram (the same for other channels) Note: the load range of each input is 24VDC, 600Ω 1.2kΩ 4 A6V10281972cen-- Fire safety and security products 07.2012

Dimension In: mm Specification Operating voltage 220 VAC/50 Hz; 110VAC/60Hz Operating temperature 0... 40 C Storage temperature 10... 50 C Relative humidity 95 % rel. Protocol CAN Terminals 1.0... 1.5 mm 2 Protection category GB4208-93 IP30 Order Information Type Part No. Designation Weight 20 100703567 Controller (Inerlocking)-252points 10.35Kg 40 100703708 Controller (Interlocking)-504points 10.50Kg Beijing Siemens Cerberus Electronics Limited No.1,Fengzhidonglu, Xibeiwang, HaiDian District, Beijing, 100094, China Tel: 10 6476 8806 Fax: 10 6476 8899 Data and design subject to change without notice. Doc No. A6V10281972cen-- Manual Edition 07.2012