RF Test Gage R&R Improvement



Similar documents
SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Wafer Level Testing Challenges for Flip Chip and Wafer Level Packages

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

Silicon Schottky Barrier Diode Bondable Chips and Beam Leads

INTELLIGENT DEFECT ANALYSIS SOFTWARE

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Test-data validation. Ing. Rob Marcelis

Comprehensive Approach to Control Contact Resistance Instability and Improve First Pass Yield of Bumped Devices

SKY LF: 20 MHz-3.0 GHz High Power SP4T Switch With Decoder

Connectivity in a Wireless World. Cables Connectors A Special Supplement to

GaAs, phemt, MMIC, 0.25 W Power Amplifier, DC to 40 GHz HMC930A

Measurement Systems Correlation MSC for Suppliers

MITSUBISHI RF MOSFET MODULE RA07H4047M

Enhancing Second Harmonic Suppression in an Ultra-Broadband RF Push-Pull Amplifier

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

1.Introduction. Introduction. Most of slides come from Semiconductor Manufacturing Technology by Michael Quirk and Julian Serda.

TQP4M3019 Data Sheet. SP3T High Power 2.6V 2x2 mm CDMA Antenna Switch. Functional Block Diagram. Features. Product Description.

EMC Expert System for Architecture Design

Spectrum Analyzer. Software Instruction Manual

Application Notes FREQUENCY LINEAR TUNING VARACTORS FREQUENCY LINEAR TUNING VARACTORS THE DEFINITION OF S (RELATIVE SENSITIVITY)

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Vertical Probe Alternative for Cantilever Pad Probing

The Phase Modulator In NBFM Voice Communication Systems

RF IF. The World Leader in High-Performance Signal Processing Solutions. RF Power Amplifiers. May 7, 2003

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption

AN-837 APPLICATION NOTE

Pristine s Day Trading Journal...with Strategy Tester and Curve Generator

Objective. Testing Principle. Types of Testing. Characterization Test. Verification Testing. VLSI Design Verification and Testing.

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Using S-Parameter and Load Pull Measurements to Validate Transistor Large-Signal Fundamental and Harmonic Tuning Performance

MASW T. HMIC TM PIN Diode SP2T 13 Watt Switch for TD-SCDMA Applications. Features. Functional Diagram (TOP VIEW)

Quick Setup Guide. Philips Lifeline GoSafe Mobile Button Landline Home Communicator

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

Delivering Dependable Performance... A Spectrum of Radar Solutions

Π8: Indoor Positioning System using WLAN Received Signal Strength Measurements Preface

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

GaAs Switch ICs for Cellular Phone Antenna Impedance Matching

23-26GHz Reflective SP4T Switch. GaAs Monolithic Microwave IC in SMD leadless package

Apple/AuthenTec TMDR92 iphone 5s, 6, and 6 Plus Fingerprint Sensor

General Survey of Radio Frequency Bands 30 MHz to 3 GHz

Outsourcing Test What are the most valuable engagement periods?

Welcome. Rulon VanDyke RF System Architect, Agilent Technologies. David Leiss Senior RF Simulation Consultant, Agilent Technologies

LCD Drawer User Manual

GHz Frequency Multiplier. GaAs Monolithic Microwave IC. Output power (dbm)

SPI HS70. Remote Control of Multiple Lines with RMCworks. Systematic Process Management by Inspection Spec Server

FEATURE ARTICLE. Figure 1: Current vs. Forward Voltage Curves for Silicon Schottky Diodes with High, Medium, Low and ZBD Barrier Heights

Modification Details.

MRF175GU MRF175GV The RF MOSFET Line 200/150W, 500MHz, 28V

Field Calibration Software

Actual vs. Programmed Overtravel for Advanced Probe Cards

Direct and Reflected: Understanding the Truth with Y-S 3

How to Cheat On A Survey Don t Be A Victim

Instructions for - Installation of Satellite Channels

Microwave Amplifier Design (part 1)

RF Switches Guide Signals In Smart Phones

ADS Tutorial Stability and Gain Circles ECE145A/218A

Implementing Voice Over Wireless Networks: Realities and Challenges

Signal Types and Terminations

Prototyping Printed Circuit Boards

Card electrical characteristic, Parallelism & Reliability. Jung Keun Park Willtechnology

KVPX CONNECTOR SERIES HIGH SPEED SIGNAL INTEGRITY REPORT

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Understanding Mixers Terms Defined, and Measuring Performance

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Electrical Hazards. Power Tools. Extension Cords

Owner s Manual channel amplifier

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

HP 8970B Option 020. Service Manual Supplement

Introduction to JIGS AND FIXTURES

LS RS. Figure 1: Assumed inductor model

VOICE OVER WI-FI CAPACITY PLANNING

DESIGN OF CLASS-E RADIO FREQUENCY POWER AMPLIFIER. Saad Al-Shahrani DOCTOR OF PHILOSOPHY. Electrical Engineering.

SKY LF: 0.5 to 6.0 GHz SPDT Switch, 50 Ω Terminated

AN1991. Audio decibel level detector with meter driver

CX Zoner Installation & User Guide

The Road to 450 mm Semiconductor Wafers Ira Feldman

Easy Machining Center Setup

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

A Guide to Calibrating Your Spectrum Analyzer

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

Scanning Acoustic Microscopy Training

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

Build your own solution with UMS

Voice over Wi-Fi Voice Quality Assessment Test

Multi-Carrier GSM with State of the Art ADC technology

Interference Analysis

Parameter Min. Typ. Max. Units. Frequency Range GHz. Minimum Insertion Loss db. Dynamic 38 GHz 26 db

Omni Antenna vs. Directional Antenna

SSPI-APPN OTES: PARALLEL C ONNECTIONS

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Salient Dashboard Designer Training Guide

Low and Stable Contact Resistance With Reduced Cleaning......A Paradigm Shift

PGA103+ Low noise, high dynamic range preamp for VHF and UHF

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

Transcription:

Percentage Contribution RF Test Gage R&R Improvement James Oerth and Mike Downs Skyworks Solutions, Inc 20 Sylvan Road, Woburn, MA, 01801, USA Tel: (781) 376-3076, Email: jim.oerth@skyworksinc.com Keywords: RF, test, gage study Abstract Advanced cell phone architectures require high performance multi-throw RF switches. Reliably measuring the very low RF power levels of the third harmonic signal of these switches is a significant challenge. This paper discusses the use of Gage studies to identify and measure the sources of variation in RF probe measurements. Tester Gage study results are presented. Evaluations of factors including test instrument repeatability, probe card wear, probe tip planarity, probe pressure, and probe placement within the bond pad are presented. The data indicated the repeatability of the test instrumentation was very good. However, the reproducibility needed improvement. The most significant factor in achieving reproducible RF measurements is sufficient probe contact. A method to provide probe operators feedback of sufficient probe contact was developed and implemented. As a result, the Gage study passed. Further, the percentage of die requiring re-test was reduced significantly. INTRODUCTION State of the art multi-throw RF switches need to meet third harmonic performance specifications in the range of -30 to -40 dbm power at RF frequencies in the range of 824 to 915 MHz. -30 and -40 dbm correspond to 1uW and 100nW of power respectively. To provide known good switch die for Skyworks Front End Modules (FEM), the Skyworks phemt wafer fab performs RF probe testing on all switch die. Reliably making these low power measurements at high frequencies in a probe test environment requires advanced test instruments and rigid production discipline. The Skyworks Quality System requires Gage studies be performed on all measurement equipment. Further, Skyworks customers can and do request measurement system Gage study results. data was reviewed and 21 functional die were selected which had a range of third harmonic performance from very good to very bad. Four operators, one from each shift, measured the die three times each. All 21 die were tested, then the setup was taken apart, put back together and the die tested again. Each of the four operators did this three times each. This maximized variation by requiring all electrical connections between the tester and the prober to be remade, the probe card to be reset, and the probe pressure adjusted each time. The top level results of the Gage study are shown in Figure 1. The total Gage study result was 14%, which is marginally passing. Results of less than 10% are considered acceptable. Results between 10% and 30% are marginal. Results greater than 30% are unacceptable. The repeatability portion of the Gage study indicates the amount of variation due to the measurement equipment. This result was very good at 0.5%. The reproducibility portion of the Gage study indicates the amount of variation due to the operator. This result was marginal at 13.5%. Figure 1 Third Harmonic Gage R&R Results Wafer Probe 3rd Harmonic Gauge R & R 100 90 80 70 60 50 40 30 20 10 0 Total Gauge R&R 13.98 Repeatability 0.52 Reproducibility 13.46 Part to Part 86.02 DISCUSSION Gage Study A Gage study for third harmonics was performed. A production wafer was taken from the line after RF test. The The third harmonic variation was analyzed by operator (shift). Systematic differences between operators were observed (Figure 2). Further, the difference between operators was larger for better performing parts. We look at it as you can make a good part bad, but you can t make a bad

part good. Note the data is shown in dbc. This is the third harmonic power level relative to the input power. dbc = input power (dbm) measured 3F0 (dbm) Table 1 Third Harmonic in (dbc) Results by Shift Table 1 List of Potential Factors Influencing Reproducibility Probe pressure/planarity Probe wear Probe cleanliness Probe placement on bond pad The hypothesis is that variations in these factors could change the third harmonic measurement by changing the impedance of the path from probe tip to each bond pad. Experiments were run to evaluate probe tip wear, probe placement within the bond pad, and probe pressure. We did not run a probe tip cleanliness experiment because we could not think of a way to dirty probe tips in a controlled manner. Probe Pressure Evaluation Figure 2 Graph of Third Harmonics By Part and Shift To evaluate the effect of probe pressure, the third harmonics were measured on the same die on the same wafer using four different probe pressure settings. A new, never been used before, probe card was used to make the measurements. This eliminated any variation due a worn or non-planar probe card. The four probe settings were 0, 0.1, 0.2, and 0.3 mil over travel. The zero pressure was when the experienced operator believed all probes were touching the bond pads. The results are show in Figure 3. The zero over travel setting resulted in highly variable results. The 0.1, 0.2, and 0.3 mil over travel reading resulted in reproducible measurements (Figure 4). The data shows with a new, planar probe card, an over travel of.1 mils is sufficient to obtain reproducible 3rd harmonic measurements. By inference, maintaining probe planarity is critical to obtaining consistent measurements. Figure 3 Third Harmonics by Probe Pressure The test engineering group met to discuss possible reasons for the reproducibility results. The team listed the factors listed in Table 1 as possible sources of test result variation than can be influenced by the operator.

Delta 3F0 dbc Figure 4 Third Harmonics by Probe Pressure Figure 6 Third Harmonics By to Probe Placement Within The Bond 3rd Harmonics By Probe Placement 78 77 76 75 74 73 72 71 70 69 68 67 1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 81 86 91 Die 3Harm_1.01.05 Lower Left 3Harm_1.01.05 Middle 3Harm_1.01.05 Upper Right Probe Placement Within The Bond Pad The placement of the probe tip within the bond pad was identified as a possible source of variation in third harmonic results. To evaluate this effect, 94 die on a production wafer measured with deliberate placement of the probe in the center and opposite corners of the bond pad (Figure 5). A newer probe card was used to make these measurements to reduce any variation due to probe tip wear. The probe card had been used for only 95,000 touches. We routinely achieve probe life in the 500,000 to 2,000,000 touches. The delta of the measurements from center placement to the corner measurements was calculated. A statistically significant difference of 0.14 dbm between the probe placements was observed (Figure 7). However, the difference was small, so in practice it is irrelevant (Figure 6). Probe placement within the bond pad is not the cause of the marginal reproducibility results of the Gage study. Figure 5 Illustration of Probe Tip Placement Within a Bond Pad Probe Placement Lower Left Probe Placement Middle Probe Placement Upper Right 0.6 0.5 0.4 0.3 0.2 0.1 0-0.2-0.3-0.4 Figure 7 Difference in Third Harmonics Due to Probe Placement Within The Bond Pad 3rd Harmonic Delta FromCenter Probe Placement -0.1 1 6 11 16 21 26 31 36 41 46 51 56 61 66 71 76 81 86 91 96 Probe Wear Upper right reduced 3 rd Harmonic by.09 db Delta C to LL Delta C to UR Lower Left increased 3 rd Harmonic by.05 db The 1 mil diameter probe tips used for RF test are very small and fragile. During usage, the probe tips wear and change from sharp to dull. The probe marks left by a new probe tip are narrower and deeper than a dull tip, which tends to be wide and push more of the bond pad metal. This wear effect was identified as a possible source of variation in third harmonic results. To evaluate this effect, two probe cards were utilized. A newer card with 95,000 touches and and older card with 1,160,000 touches were used. Figure 8 shows the third harmonic results sorted from best to worst. Figure 9 shows the point by point difference between the two probe cards. There was no statistically significant difference observed between an old and new probe card. Probe tip wear is not the cause of the marginal Gage study result for reproducibility.

3rd Harmonics dbm 3rd Harmonics dbc 78 77 76 75 74 73 72 71 70 69 Figure 8 THIRD HARMONICS VS PROBE TIP WEAR RP0985 3rd Harmonic by Probe Wear 68 1 5 9 131721252933374145495357616569737781858993 Die 3Harm_1.01.05 95K touches 3Harm_1.01.05 1.16M touches Figure 10 Wafer Map Showing Atypical Pattern Due to Probe Pressure. Blue color is for failing die Figure 9 Difference in Third Harmonics Due to Probe Tip Wear 0.2 0.15 0.1 0.05-0.1-0.15-0.2-0.25 Delta between 95k & 1.16M No significant difference observed between new and worn probe card 0 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 Delta between 95k & 1.16M -0.05 Repeat of Gage Study For Third Harmonics The Gage study was repeated with carefully controlled probe pressure. Once again, four operators were used in the study each repeating their measurements three times with the set up being redone after each measurement. The results showed the reproducibility improved from 14% to less than 1%. See Figure 11 and 12. Figure 11 Gage Study Repeat After Learning Improving Control of Probe Pressure G age R & R 3rd Harmonics -35 1 9 17 25 33 41 49 57 65 73 81 89 97 105 113 121 129 137 Shift The operator is responsible for setting probe pressure using our EG4090 and EG2001 automatic probers. To ensure adequate probe pressure, the test engineering group at Skyworks developed a visual system to aid the operators. A wafer map is generated real time as the wafer is being tested. The map indicates passing die, functional die that fail, and non-functional die. Functional die are those which pass a minimal functional screen but do not pass the high performance specifications. The non-functional die fail the minimal screen. When die fail the functional screen, some special cause is at work. For example, an out of control process step, equipment failure, or operator error. The limits have been chosen such that poor probe contact is reported as non-functional die. When an operator sees excessive non-functional die, the probe pressure is one of the items to be checked (Figure 10). Typically, when probe pressure is insufficient, an abnormal pattern in the data is revealed. -40 A1 A2 A3 B1-45 B2 B3 C1-50 C2 C3 D1 D2-55 D3-60 Part Trial # The 3 rd Harmonic Measurements were both repeatable and reproducible. Each die was measured 12 times. 4 operators (on 4 shifts) measured each part 3 times. The Average range of the 12 measurements for 139 die was 0.48 dbm.

Range of 12 Readings Figure 12 Gage Study Repeat After Learning Reproducibility Figure 14 RF Probe Re-Test Rate Before and After Probe Pressure Control Probe Re-Test Rate Before and After Probe Pressure Control 16.00% 6.00% 5.70% 14.00% 12.00% 10.00% 13.50% 5.00% 4.00% 8.00% Reproducibility 3.00% Probe Re-Test Rate 6.00% 2.00% 4.00% 1.30% 2.00% 1.00% 0.00% Original 0.04% Repeat 0.00% Before After The range each of the twelve readings was calculated (4 operators, 3 times each) for each of the test data points. The range was then plotted as a function of the third harmonic performance. Figure 13 shows the range of measurements increases with increasingly better third harmonic performance. At -40dBm (100nW), the range of 12 repeated readings was <0.5 db. Above -50 dbm (10nW), the range of measurements increases. This is likely due to reaching the noise floor of the test hardware. Figure 13 Range of 12 Repeated Measurements vs Performance Range of 3rd Harmonics vs Harmonic Measured CONCLUSIONS It was shown that Gage studies are a useful tool to identify and reduce variation in RF test results. Probe placement and probe wear were observed to be insignificant factors in third harmonic measurement results. Insufficient probe pressure was identified as a plausible explanation for marginal reproducibility of the third harmonic measurement in our initial Gage study. A repeat of the gage study passed with careful attention to probe pressure. A method to provide probe operators feedback of sufficient probe contact was developed and implemented. As a result, the percentage of die requiring re-test was reduced significantly. 2.00 1.80 1.60 1.40 1.20 1.00 0.80 Range ACKNOWLEDGEMENTS The authors would like to thank Steve Cousineau, Leo Sennott, Ed Aspell, and Jorge Willemsen for the Parameter Viewer wafer mapping tool they developed. 0.00-60.00-55.00-50.00-45.00-40.00-35.00-30.00 Re-Test Rate Average 3rd Harmonics After learning the significant contribution to variation in probe results that is caused by probe pressure control and implementing the visual aid for operators to recognize insufficient probe pressure, the need for re-test decreased (Figure 14). 0.60 0.40 0.20 REFERENCES [1] J. Oerth, C. Doucette, S. Singh, S. Doonan Yield Improvement Methodology in a phemt GaAs Fabrication Facility 2008 International Conference on Compound Semiconductor Manufacturing [2] L. Sennott Web Based Business intelligence for Semiconductor Manufacturing 2009 International Conference on Compound Semiconductor Manufacturing [3] R. Green RF Measurement Test Basics For the Non-RF Engineer Keithley Instruments, Inc. ACRONYMS RF: Radio Frequency phemt: Pseudomorphic High Electron Mobility Transistor Gage R&R: Gage Repeatability and Reproducibility