Teseq ESD Simulator Verification

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

AN3353 Application note

Automotive Electronics Council Component Technical Committee

Frequency Response of Filters

Cable Analysis and Fault Detection using the Bode 100

Impedance 50 (75 connectors via adapters)

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Kit Watt Audio Amplifier

CAN bus ESD protection diode

2. The Vector Network Analyzer

TEST REPORT EN (1997) +A1 (2001)

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Measuring Impedance and Frequency Response of Guitar Pickups

AMP CO Plus Insert for Cat. 6 A Applications

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

METHODS FOR THE CALIBRATION OF ELECTROSTATIC MEASURING INSTRUMENTS

Test Report #: Date: April 8, 2005

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

CDM Testing. Marcos Hernandez

Current Probes, More Useful Than You Think

FM Radio Transmitter & Receiver Modules

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

PS323. Precision, Single-Supply SPST Analog Switch. Features. Description. Block Diagram, Pin Configuration, and Truth Table. Applications PS323 PS323

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

Current Probes. User Manual

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Coupling/Decoupling Networks (CDN)

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

SECTION 2 Transmission Line Theory

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

NI USB-5681 RF Power Meter Specifications

Agilent Time Domain Analysis Using a Network Analyzer

RClamp0821P. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics

LOW LOSS CABLE PAG. 1

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

ESD Line Ultra-Large Bandwidth ESD Protection

Utilizing Time Domain (TDR) Test Methods For Maximizing Microwave Board Performance

ELECTRON SPIN RESONANCE Last Revised: July 2007

SCS Directory Accreditation number: SCS 0115

uclamp0541z Ultra Small μclamp 1-Line ESD Protection

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

RClamp0504P RailClamp Low Capacitance TVS Array

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

TI GPS PPS Timing Application Note

PRTR5V0U2F; PRTR5V0U2K

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Evaluating Oscilloscope Bandwidths for Your Application

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4]

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

MEASUREMENT SET-UP FOR TRAPS

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

A wave lab inside a coaxial cable

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Lab #9: AC Steady State Analysis

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Application Note SAW-Components

uclamp3301h Low Voltage μclamp TM for ESD and CDE Protection PRELIMINARY Features

RClamp0522PA RClamp0524PA

Design and Certification of ASH Radio Systems for Japan

PIEZO FILTERS INTRODUCTION

Features. Symbol JEDEC TO-220AB

How To Make An Electric Static Discharge (Esd) Protection Diode

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

The EMI-Receiver according to CISPR

11: AUDIO AMPLIFIER I. INTRODUCTION

Understanding Power Impedance Supply for Optimum Decoupling

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Transcription:

Teseq ESD Simulator Verification

Background Greg Senko, President Teseq Inc. North American division of Teseq Laboratory Technical Manager Edison NJ This presentation was first given in 2003 when lab was Schaffner Co-authored with Ken Wyatt, Lab Manager Agilent Technologies Teseq first ISO 17025 accredited by A2LA March 2006. Audited for re-accreditation in 2008 and 2010 & 2012. Teseq scope of accreditation now includes IEC 61000-4-2: 2008-12 as well as many other industry standards: EN 61000-4-2, IEC 801-2, ISO TR 10605, ISO 10605, SAE J1113-13, ANSI C63.16, FORD ES-XW7T-1A278-AC, GMW 3097, DC-10614, DC-11224 Presentation includes these updates and experiences 2

Outline Virtually every EMC laboratory has one or more ESD simulator. Many are equipped to verify the ESD simulators performance but few to the latest requirements. Topics: Verification techniques, including ISO, SAE, ANSI and IEC standards Latest changes to verification requirements How the new systems compare to older systems Practical aspects of measurement setup and performance Conflicts between specifications Recommendation for air-discharge verification 3

ESD Simulator Verification What parameters must be measured? Tip voltage continuous, not discharge Current waveform contact discharge Peak Rise time Current at 30ns (for IEC network) Current at 60ns (for IEC network) Current waveform air discharge (automotive only) Rise time Time Constant 4

ESD Simulator Verification Measuring tip voltage Measured at standard test levels: ±2kV, ±4kV, ±6kV, ±8kV, ±15kV and ±25kV Measured using Electrometer or Giga-ohm meter Most standards don t specify requirements ISO 10605 specifies 100GOhm minimum input impedance The simulator s tip voltage not affected by the measurement If a Giga-ohm meter is used, the simulator must continuously charge the high-voltage capacitor 5

ESD Simulator Verification Tip voltage measurement using Giga-ohm meter 6

ESD Simulator Verification Idealized ESD simulator waveform 7

ESD Simulator Verification Actual waveform measurement 8

Measurement System How do we measure the current waveform? A low impedance shunt is used to represent a discharge into a large metallic object The shunt impedance is < 2.1 Ohms Block diagram: TARGET ESD ATTENUATOR OSCILLOSCOPE 9 GROUND PLANE CABLE

Measurement Target Axial resistors IEC 61000-4-2 target Found where older standard editions are referenced Difficult to precisely control dimensions, center can shift Poor impedance control 10

Insertion loss [db] Typical transfer characteristic of a Pellegrini target (MD 101) 15 15 20 25 Ins ertion los s of the Pellegrini target 30 S21_dB 35 40 45 50 11 60 55 60 1MHz 1 10 9 2 10 9 3 10 9 4 10 9 5 10 9 6 10 9 f_mess 6GHz frequency [Hz]

Measurement System Typical ESD current measurement system with Faraday cage example from IEC 61000-4-2 12

Measurement System Typical ESD current measurement system actual system used in some Teseq labs 13

Attenuators Choosing attenuators Target transfer function is ~1V/A when loaded by 50 Ohms Contact mode peak current at 8kV is ~30A Input range of most oscilloscopes is < 10V in 50 Ohm mode Attenuator is needed to reduce the signal level 20dB is typically chosen for 10:1 ratio Contact mode to 25kV may require additional attenuation 14

Attenuators Choosing attenuators Low power attenuators may damaged by the short term peak power Attenuators are available with 1kW peak power ratings Use an 18GHz attenuator with low SWR, < 1.25 to 8GHz The attenuator accuracy requires that the entire chain be calibrated Accuracy variation db Percentage 0.1 1.16% 0.3 3.51% 0.5 5.93% 0.7 8.39% 0.9 10.92% 15

Cables Choosing cables A low loss cable is required Cable length < 1m is required by most standards Double shielding is required by most standards The ANSI standard recommends RG 400 RG 214 is twice the diameter, 1/2 the loss and is commonly available 16

Bandwidth Oscilloscopes - bandwidth The BW/risetime of the oscilloscope is the single most limiting factor to accurately measure the pulse risetime. The true risetime is related to the observed risetime as follows: risetime esd _ pulse risetime 2 observed risetime 2 measurement _ chain The above correction is proposed in the ANSI draft standard and assumes a Gaussian rolloff in frequency response. However most digitizers use a sharper cutoff filter, 20dB/decade or higher. 17

ESD Simulator Verification How does bandwidth affect observed risetime? Let s assume a Gaussian rolloff Oscilloscopes - bandwidth Pulse Risetime (ps) Scope BW (GHz) Scope Risetime (ps) Observed Risetime (ps) Difference % Error 700 1 350 783 82.62379 11.8% 700 1.5 233 738 37.86479 5.4% 700 2 175 722 21.54348 3.1% 700 3 117 710 9.655629 1.4% 700 4 88 705 5.447553 0.8% 700 6 58 702 2.42635 0.3% 18

ESD Simulator Verification Oscilloscopes sampling rate Single-shot sampling rate is the key Sharp/traingular peak requires fast sample rate Risetime of 800ps from 10%-90% is 80% of waveform 10Gs/s = 100ps/sample 8 samples in 800ps or 10%/sample! Since peak is symmetrical and somewhat rounded actual error is < 5% Effective sampling rate increased by capturing multiple shots Must have stable waveform Contact mode only - never for air discharge Shot to shot variation is low for most simulators Should be used for verification - not for calibration 19

ESD Simulator Verification Shot to shot variation 20 shots 33.3A peak Std dev.425 ±0.64% of peak 898ps Rise Std dev 11.9 ±0.66% of risetime 20

Sampling Rate Oscilloscopes sampling rate SAE and ISO recommend 4Gs/s minimum 2 Gs/s - 27.87A -16.0% 10 Gs/s - 32.23A -2.9% 5 Gs/s - 31.92A -3.8% 20 Gs/s 33.18A 21

Interpolation / Vectors Oscilloscopes interpolation ON or OFF? Interpolation ON Interpolation OFF 22

ESD Simulator Verification Other factors Dos and don ts Shielding Do we need it? Position of ground cable Will it affect waveform? Orientation of simulator Will it affect waveform? Automatic Measurements Must use Min and Max values to calculate 10% and 90% points Other cables Keep them well separated 23

Faraday Cage? Oscilloscope shielding do we need it? Standards say yes, but probably not necessary - use distance test Scope inside chamber Scope at corner of plane Scope next to simulator 24

Measurement System Working ESD current measurement system without Faraday cage 25

Ground Cable Ground cable position Does affect results peak, rise and duration 20 Gs/s - 33.6A, 891ps Natural loop Loop closer to plane 20 Gs/s - 36.9A, 926ps 26

Simulator Orientation Simulator orientation to target Does affect results peak, rise and duration 20 Gs/s - 33.6A, 891ps 20 Gs/s - 33.6A, 913ps 20 Gs/s - 34.5A, 945ps Simulator on axis Simulator up 10 Up 30 27

Air Discharge Waveform Air discharge What risetime/peak do you want? Approach speed and environmental factors will greatly affect results - not repeatable Obtaining a passing waveform is a matter of patience! 28

The New IEC -4-2 Changes to Simulator Verification in IEC 61000-4-2: 2008 Method for measuring low frequency system transfer impedance Improved measurement target with RF specifications to 4GHz Target calibration adapter defined Minimum 2GHz oscilloscope bandwidth Faraday cage may not be required Peak current tolerance relaxed from ±10% to ±15% Minimum rise time reduced from 700ps to 600ps Ground cable position defined Uncertainty calculation examples in Appendix E 29

Target Evolution Target design history IEC 801-2: 1991 No longer referenced by any current standard No performance specifications Poor design - lots of ringing Small ground plane IEC 61000-4-2: 1995, 2001 Referenced by virtually all current standards No performance specifications Transfer function zero at 5-6 GHz IEC 61000-4-2: 2008-12 New design with flatness specified to 4GHz 2GHz Oscilloscope required Adapter to evaluate high frequency performance 30

A Better Target IEC 61000-4-2: 2008 Target (example) SMD resistors Tighter tolerances Better impedance control 31

ESD Simulator Verification Waveforms of IEC 801-2 target vs. ANSI target IEC 801-2 target ANSI target Less HF ringing and shows true peak shape 32

Commercial Target System New target with adapter to measure transfer characteristics Calibration Adapter Measurement Target 33 Tool for removing center

Target Calibration Calibrating the target-attenuator-scope chain It is recommended that the DC transfer function of the entire chain be measured as follows: Inject a known current Measure the resulting voltage at the oscilloscope The attenuation factor = Injected current / Observed Voltage Attenuation factor is used to correct waveform amplitude CURRENT SOURCE TARGET CABLE ATTENUATOR ATTENUATOR OSCILLOSCOPE GROUND PLANE 34

Target Calibration IEC 61000-4-2 target and adapter specifications Variation of attenuation of the adapter-target-attenuator-cable chain < ±0.5dB from DC to 1GHz (< ±5.9%) < ±1.2dB from 1GHz to 4GHz (< ±14.8%) Adapters must be tested too! Return loss of two adapters face-to-face > 30dB from DC to 1GHz > 20dB from 1GHz to 4GHz Insertion loss of two adapters face-to-face < 0.3dB up to 4 GHz 35

Ground Cable Orientation IEC 61000-4-2: 2008 and ISO 10605: 2008 36

Scope Bandwidth Effects TDS 7104, 1GHz, 10GS/s Peak I 29.02A Rise 827ps I 30 16.8A I 60 8.8A Sample rate - 40ps/s Oscilloscope 1GHz vs. 2.5GHz oscilloscope 37 TDS 7254, 2.5GHz, 20GS/s Peak I 28.17A Rise 803ps I 30 16.5A I 60 8.3A Sample rate 10ps/s

ESD Simulator Verification Measurement uncertainty The estimated bounds of the deviation of a measured quantity from its true value List all the possible error sources and compute the uncertainty Uncertainty budget for each measured parameter Statement of confidence that can be placed in the value of uncertainty Does measured result truly fall within acceptable limits? National Association for Measurement and Sampling publication NIS81, The Treatment of Uncertainty in EMC Measurements Extensive reference information with examples in IEC 61000-4-2: 2008 Appendix E 38

The New 10605 Changes to Simulator Verification in ISO 10605: 2008 New RC networks added to existing 150pF / 2kΩ, 330pF / 2kΩ 150pF/ 330Ω same specs as IEC 61000-4-2 330pF/ 330Ω DC 10614 New networks have IEC-like limits ±10% peak vs. +30/-0% No air discharge verification variability too high Voltage Approach speed Humidity Arc length Ionization 39

Comparing Standards New 330/330 network No issues RC Network: 330pF, 330Ω Contact Rise Time IEC 61000-4-2: 2001 IEC 61000-4-2: 2008 ISO 10605: 2008 Ford CS-2009, GMW 3097: 2006 ISO 10605:2001 O O 0.7-1.0ns O O 1rst Peak O O +10/-10% O O Air Discharge O O O O O Current at 30, 60ns O O ±30% O O 40

Comparing Standards Certificate to IEC -4-2 does not fulfill ISO 10605 RC Network: 150pF, 330Ω Contact Rise Time IEC 61000-4-2: 2001 IEC 61000-4-2: 2008 ISO 10605: 2008 Ford CS-2009, GMW 3097: 2006 ISO 10605:2001 0.7-1.0ns 0.6-1.0ns 0.7-1.0ns O O 1rst Peak +10/-10% +15/-15% +10/-10% O O Air Discharge O O O O O Current at 30, 60ns ±30% ±30% ±30% O O 41

Comparing Standards 10605: 2008 Cert. does not fulfill Ford and GM, use 2001 ed. RC Network: 150pF, 2kΩ 330pF, 2kΩ Contact Rise Time IEC 61000-4-2: 2001 IEC 61000-4-2: 2008 ISO 10605: 2008 Ford CS-2009, GMW 3097: 2006 ISO 10605:2001 O O 0.7-1.0ns 1.0ns 0.7-1.0ns 1rst Peak O O +30/-0% +30/-0% +30/-0% Air Discharge O O O Current at 30, 60ns Rise 20ns, Time Const. Rise 5ns, Time Const. O O ±30% O O 42

That Pesky Air-Discharge! Requirements from ISO 10605: 2001 Only single events are allowed Start at least 15mm away from the target Approach slowly, 5mm/s or less Levels are 4, 8 and 15kV both polarities Rise time must be less than 5ns Acceptable waveforms must be repeatable at least 6 of 10 attempts Time constant is 300ns ± 60ns for 150pF network Time constant is 660ns ± 130ns for 150pF network Target from IEC 61000-4-2: 1995 referenced, no target plane req s 43

That Pesky Air-Discharge! Series of 20 Discharges, 12 of 20 <5ns 4.63ns 6.66ns 7.79ns 3.02ns 8.10ns 4.16ns 4.35ns 5.89ns 2.82ns 3.35ns 3.03ns 5.39ns 3.25ns 5.56ns 3.10ns 5.45ns 4.12ns 3.63ns 2.70ns 5.14ns 44

That Pesky Air-Discharge! Series of 20 Discharges, Event #1 45

Do you Remember this Measurement Target? ISO 10605: 1994 Target from IEC 801-2 with Ball Tip 46

Balls of Steel Spherical center exchanged for flat center 47

Spherical Center How do we know the HF characteristic is OK? Standard Center Rise 817ps Peak 27.9A Spherical Center Rise 822ps, +5ps, reproducibility 14ps Peak 28.0A, +0.1, reproducibility 0.24A 48

49 Spherical and Standard Center Waveforms Overlayed

That Pesky Air-Discharge! Summary Some checks should be applied There will be a high degree of variability shot-to-shot Internal contact discharge relays increase variability Environmental characteristics pay a big role Contact shape affects discharge waveform Flat targets perform worse than spherical centers Spherical center does not alter target characteristics 50

Multiples Are they really there? Very hard to capture A second and sometimes a third discharge occurs Typically >100ms between discharges Fast sampling rate required to catch event, >1Gs/s Long record length required For 500ms, 500Mb! Peak detect sampling mode works well 51

Multiples Two ESD simulators from different manufacturers Photos are enhanced to make peaks more visible 52

Multiples Why do they occur? At 15kV, the first discharge arc occurs well before the contacts touch Arc can be 5 to >10mm At 5mm/s, 1 2 seconds from first arc to contact The ESD discharge lasts for just 10 s of nanoseconds Arc extinguishes when current is low but before all energy discharged Additional discharge happens when tip gets close enough for new arc, approx. 200 400ms after first event 53

ESD Simulator Verification Thank you for your attention Your feedback is welcome Gregory Senko, President Teseq, Inc. 978-764-7358 gregory.senko@teseq.com 54