Siemens S7 PLC and FC 300 Profibus



Similar documents
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Continuous PROFIBUS PA Instruments and Step 7. Configuring a Siemens Continuous Level PROFIBUS PA device in a S7-300 or S7-400 PLC

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

1 Application Description Objective Goals... 3

Manual. MOVIDRIVE MDX61B MOVI-PLC DHP11B Control Card. Edition 09/2005 FA / EN

S7 for Windows S7-300/400

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

AF-650 GP TM & AF-600 FP TM Profibus DP. Instruction Manual

Development of a Gateway to PROFIBUS for Remote Diagnostics

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

PROFIBUS fault finding and health checking

Commissioning IDENTControl Compact IC-KP2-2HB17-2V1D Profinet Protocol with a Siemens S7 PLC

Install the DeviceNet Module using the following procedure:

L5354 ControlNet Communications Interface

Manual. Fieldbus Interface DFP21B PROFIBUS DP-V1. Edition 07/2006 FA / EN

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

TECHNICAL NOTE TNOI34

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

Service & Support. How can you establish a connection between a S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

Industrial Training Schedule Spring 2012

Configuration a Profibus-DP node using Step7 and WAGO-I/O components Application note

Application about Communication

Everything you ever wanted to know about DPV1 diagnostics but were afraid to ask!

Introduction to PROFIBUS and PROFINET

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE C2. High Level Programming with S7-SCL

SIEMENS S

1 How configure S7 PLC in the configuration tool

RcWare SoftPLC Modbus server mapping editor User manual

QuickPanel Control DeviceNet Master Communications Card (IC754DVNM01) Quick Start Guide. Thursday September 20, 2007

FAQ configuration profibus example for series SX502


PROFINET IO Diagnostics 1

Service & Support. How can you establish a connection between an S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

FAQ Communication over IE

Contents. MCT 10 Set-up Software. MCT 10 Set-up Software

Technical Report CDC PC Station Guide Tutorial Nuno Cruz

Profibus DP V1. About this Document Profibus DPV1 introduction Principle of data exchange by Profibus DPV1... 4

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

Pluto Gateway Siemens S7 Integration Manual

S7 OPC Server Tutorial

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

SOFTLINK 300. CPU Specifications. Reference Manual

SIMATIC Expert Communication Connecting S7-400H to PC Station (WinCC)

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

G3 Series PROFIBUS DP Technical Manual

Service & Support. How Can You Have Diagnostics Data of IPCs Displayed in WinCC? WinCC, IPC and DiagMonitor. FAQ July Answers for industry.

FAQ about Drive Technology

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

CB15/CB155. PROFIBUS Module

The CP FO provides access to different communication services of the PROFIBUS bus system:

Cover sheet. Consistent Data. PROFIBUS DP and PROFINET IO. FAQ September Service & Support. Answers for industry.

Applications & Tools. Connecting a SINAMICS G120 Drive to an S7-300/400 CPU in TIA Portal V11 SINAMICS G120 (CU 240E-2 PN(-F)), SIMATIC S7-300/400

SIMATIC. ET 200S distributed I/O IM151-1 STANDARD interface module (6ES7151-1AA05-0AB0) Preface. Properties 1. Parameters 2.

How-To-Do. Hardware Configuration SLIO CPU 014

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

PROFIBUS diagnostics and network monitoring

State of Michigan Data Exchange Gateway. Web-Interface Users Guide

Research of PROFIBUS PA s integration in PROFINET IO

Permissible ambient temperature Operation Storage, transport

CP Page 1342 Mar 2008 Siemens ITS

Start-up of IVI-KHD2-4HRX, IVI-KHA6-4HRX at S7-300 V1.1. Table of Contents TABLE OF CONTENTS... 1

Application Note Profinet Modules

USER S MANUAL. Profibus Option Card For Toshiba VF-S11 Inverter

The CP provides access to different communication services of the PROFIBUS bus system:

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

DeviceNet Motor Control

Anybus OPC Server. Application Note. Doc.Id. SCM Rev HMS Industrial Networks AB

GE Proficy Machine Edition Profibus/Profinet SARTUP GUIDE

Configuring PROFINET

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

User Manuals. Connection to Siemens S5 PU (AS511) Part Number: Version: 2. Date:

1 Application Description System Topology Hardware and Software Requirements... 3

Radio Interface Setup

SmartWire Panel Wiring Solutions the easy way to connect

Applications & Tools. Configuration and Diagnostics of a PROFINET IO System. PROFINET IO Configuration Example. Application Description January 2010

UE4140 PROFIBUS PROFIsafe UE4740 PROFINET IO PROFIsafe UE1140 PROFIBUS UE1840 Ethernet TCP/IP UE1940 CANopen

The Answer to the 14 Most Frequently Asked Modbus Questions

PROFIBUS / MODBUS GATEWAY Application Note for Communication between Premium CPU & XPS-MC Safety Controllers

VLT Motion Control Tools MCT 10 Set-up Software

Profinet to EDV111 Series LED Signs Siemens Function Block Software Manual

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

GW-7552 PRIFIBUS/MODBUS GATEWAY

6ES BE01-0AB0 6ES BE01-0AB0

RFID systems. Communications modules ASM 450 4/139. Overview

MCT 10 Setup Software

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

User Manual Revision English

Omron I/O Driver (Series 2) Programmable Serial Interface Card

Transcription:

Introduction This application note describes how to set up a PROFIBUS system between a Danfoss Drives FC 300 frequency converter and S7 PLC 315-2 from Siemens. It is assumed that you are already familiar with the Simatic S7 system. Only the steps which are required in order to establish communication between the FC 300 Profibus and the Simatic S7-315-2 DP PLC are shown. NOTE!: The examples do not describe all the functions needed for a real application, for example error handling. This note describes: System description Downloading and troubleshooting Check of communication Simatic project for download Details of some of the components/ software: FC 300 with PROFIBUS interface - sw. version 2.xx. FC 300 GSD version 2.00 PLC S7-315-2 DP (6ES7 315-2AG10-0AB0 / V2.0) SIMATIC Manager version 5.3 + SP1 System description The drawing shows the system in this application note. On the PROFIBUS network the stations are programmed in the following way: S7 PLC 315-2 DP: Address number 1. FC 300: Address number 5 PPO Type 2 Module consistent. 1

Start the SIMATIC Manager and create a new project. Open Hardware configuration in S7 Manager to configure the system. In order to configure a PROFIBUS system, the configuration tool needs a GSD file for each type of slave on the network. The GSD file is a PROFIBUS DP "standard" text file containing the necessary communications setup data for a slave. Download the necessary GSD files at http://www.danfoss.com/businessareas/ DrivesSolutions The first step in configuration of the PROFIBUS Master is to import the GSD file in the configuration tool. The steps outlined below show how to add a new GSD file to the Simatic Manager software tool. For each drive series, a GSD file is typically imported once only, following the initial installation of the software tool. Using the browser for the GSD file, choose to install the needed GSD files. Both the GSD file and a bitmap for the device will be imported into the Hardware catalogue. 2

The GSD file is now imported and will be accessible via the following path in the Hardware catalogue. Note that the GSD revision should display a revision higher than 2.00. Insert a Profibus network and add a PROFIBUS Master system. Setup the Profibus network to a baud rate from 9.6 kbaud to 12 Mbaud. Select FC 300 from the Hardware catalogue and drag and drop it to the PROFIBUS network. A window for the address of the FC 300 now appears. Select the address from the scroll-down list. Note that this address setting must match the address setting in par. 9-18 Node address. 3

The next step is to set up the peripheral input and output data via a PPO type. In the peripheral area data is transmitted cyclically via PPO types. In the example below, a PPO type 2 Module consistent is dragged and dropped to the first slot. The choice of PPO type is made in the master configuration, and is then automatically recorded in the frequency converter. No manual setting of PPO types in the FC 300 is required. The current PPO type can be read in par. 9-22 Telegram selection. In addition, all PPO types can be set up as word consistent or module consistent. For FC 300, the process data area can be word or module consistent, whereas the parameter channel must always be module consistent. Module consistent data is transmitted as sets of interrelated words transferred simultaneously between the PLC program and the Profibus master. Word consistent data is transmitted as individual independent words between the PLC and the Profibus master. 4

The system is now set up to use the PPO type 2 in the following peripheral I/O area: Parameter Characteristic (PCA), i.e. read and write to parameters. Process data, i.e. write a Control word and Reference and receiving a Status word and Main Actual Value. Parameter channel (PCA) PCA Index High PVA PQW PQW PQW 256 258 260 Low PVA PQW 262 Master to Slave Process channel (PCD) PCD 1 PCD 2 PCD 3 PCD 4 PCD 5 PCD 6 Control Reference Torque Ramp 1 Empty Empty word limit up time PQW 264 PQW 266 PQW 268 PQW PQW PQW 270 272 274 Parameter channel (PCA) PCA Index High PVA PIW PIW PIW 256 258 260 Low PVA PIW 262 Slave to Master Process channel (PCD) PCD 1 PCD 2 PCD 3 PCD 4 PCD 5 PCD 6 Status Main Actual Motor Frequency Digital Empty word Value current input PIW 264 PIW 266 PIW PIW 270 PIW PIW 268 272 274 PQW means the data from the Master to the Slave. By PCA the output data will contain the request of a parameter read or write. By Process data the first word of output data is the Control word of the FC 300 and the next is the Reference. The rest of the words can be freely configured to transmit different kind of data to the FC 300 in parameter 915 PCD Write Configuration. PIW means the data from the Slave to the Master. By PCA the input data will contain the response of a parameter read or write. By Process data the first word of input data is the Status word of the FC 300 and the next is the Main Actual Value. The rest of the words can be freely configured to transmit different kind of process data in parameter 916 PCD Read Configuration. See example on next page. 5

Normally the setup of the PCD area is done in parameter 915 PCD Write Configuration and 916 PCD Read Configuration via the LCP or the MCT 10 Setup Software. In FC 300 it is possible to automatic configure the PCD area in the PLC via the GSD file in Simatic Manager. The configuration of parameter 915 and 916 is done when either the PLC or the VLT is being power up via the parameterise telegram. Note that to configure the PCD area via the PLC the FC 300 and the GSD file need to have a software version higher than 2.00. Double click on the FC 300 and the click on Parameter assignment: By Device-specific parameters it is possible to use the Scroll down list to setup the PCD area. Remember to chose "Enable Autoconfig" for automatic configuration of PCD data. P915/0 to P915/9 is process data written from the PLC to the FC 300, PQW area. P916/0 to P916/9 process data from the FC 300 to the PLC, PIW area. 6

The Parameter channel can only be access as consistent data and there for System Function Call (SFC) are needed. In Simatic you should use SFC 14 for reading data and SFC 15 for writing data. The Process channel can be access as module or word consistent. In this example module consistent is used and therefore again SFC 14 / 15 is needed. If a PPO type 2 Word consistent was chosen the peripheral I/O area can be access in each word. 7

Downloading and troubleshooting Set the PLC in stop with the key on the PLC processor and download the program. Note that the FC 300 will show a Fieldbus fault while the PLC is in Stop mode. Before the PLC can be set in RUN mode ensure that the node address in par. 918 match the corresponding address in the program. Note that a change of parameter 918 is first active at next power up. After the download of the PLC program the LED marked as "NS" on the Profibus card should be solid green when the key on the S7 master is set in RUN. This indicate that the master and slave is communicating. The LED marked "MS" indicates the module status, i.e. acyclical DP V1 communication from either a PROFIBUS master class 1 (PLC) or a master class 2 (MCT 10, FDT tool). When this light shows constant green, then DP V1 communication from master classes 1 and 2 is active. If the "NS" LED on the FC 300 Profibus card isn't solid green the fault could be: - Wrong address setting in parameter 918 Node address according to the master. - After changing the parameter 918 Node address the power hasn t been cycle. - Wrong cable connection, check the cable by the master and the FC 300. 62 = RxD/TxD-P Red cable 63 = RxD/TxD-N Green cable - The termination of the Profibus network isn't correct done. - Wrong GSD file. Check that the used GSD file is for FC 300. See the FC 300 Profibus Operating Instruction for a more comprehensive troubleshooting. Check of the communication To easily check the communication between a Master and the FC 300 in the Simatic Manager a Variable Table (VAT) can be created. Go to S7 Programs and Blocks and create a VAT table. 8

Check of the communication Open the VAT table and insert a range of variable from PIW 256 of 10 words and range of variable from PQW 256 of 10 words. Now the peripheral input data from PIW 256 274 can be monitored by clicking on the glasses. In this example the peripheral input data will show the following: - PIW 256 shows the PCA response of a parameter transfer double word (parameter 351). - PIW 262 shows the data of parameter 351 (300) - PIW 264 shows the FC 300 Status word - PIW 266 shows the Main actual Value - PIW 268 shows the actual Motor current (1.55 Amp) - PIW 270 shows the frequency (12.6 Hz) - PIW 272 shows the status of the digital inputs (terminal 19 = 1) 9

Simatic project A Simatic project is available for downloading on http://www.danfoss.com/ BusinessAreas/DrivesSolutions. This project contains a Function Block 50 which can be used to parameterise and control a FC 300 via PP0 type 2 Module consistent. Download the zip file???. 10