Solenoid Operated Directional Valves



Similar documents
Solenoid Operated Directional Valves

DIRECTIONAL CONTROL VALVES

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

2/2 and 3/2 Way Size 6 Seat Valves

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

SOLENOID VALVES 3-4 WAY

Directional Control Valves

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

3/2- and 2/2-way cartridge valve type BVE

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Unit 24: Applications of Pneumatics and Hydraulics

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Single sub-base valve

Control block EDD Modular Directional Valve

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

General Purpose Relays Accessories. Accessories Miniature Relay PT

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

4 Posiflow Proportional Solenoid Valves

KDG3V-5/7/8, 10 Series

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Assisted lift operated 2/2-way solenoid valves Type EV250B

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

PVH131/141 Variable Displacement Piston Pump - 11 Design

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

3 Port Solenoid Valve

3 Port Solenoid Valve

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

3/2 Solenoid Cartridge Valve, Size 6

Series PVP Variable Volume Piston Pumps

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Circuit Breakers. NRC Series. NRC Series

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Electro-pneumatic control valves

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

Pressure Relief Valves for Pipe Mounting

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

15/40/80CN Series Medium Pressure Filters

Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment

RY2 miniature industrial relays

Variable Displacement Pump AA10VSO

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Load-sensing control block in mono and sandwich plate design

Cable Plug acc. to DIN EN , Form A

Chapter 6: Check Valves

Electro-hydraulic pressure switches type DG

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Electro-Pneumatic Bus Door Control Mechanism

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Valves. Sub-Base Mounted Valves to ISO 5599/2

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

FAQ s on Siemens Magmeters

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Directional seated valves type VP 1

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

3/2-way Solenoid Valve, direct-acting, NC or NO

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Series Hose Reels

Pressure relief valves Size 6

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

15/40/80CN Series Coreless Medium Pressure Filters

mpm DIN CONNECTORS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Hydraulic Flow Control Valves

Proportional Control Valves

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

2.12. page Products for Explosion hazardous Environment

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

3/2-way Mini Solenoid Valve

TS93 EMR T/PT/TDE. Surface applied door closer

STC 3S A Series Solenoid Valves

Line-Mounted Valves L Series

Pressure Relief. Pressure Relief Valves. Vickers

a Nexans company Catalogue 2014

Example. Fluid Power. Circuits

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Transcription:

INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35

Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working pressure*. Oil Immersed, Quiet Solenoid Design: Moving core immersed in hydraulic oil provides quiet operation. High Tank Port Pressure: Up to 3000 psi tank port back pressure (Check each spool type for max. allowable). Twin Tank Line Design: Upper and lower tank line channels (Double Loop) greatly reduces pressure drop. Wiring: Electrical box with indicator lights and terminal strip connection standard. DIN connector provided standard on DIN style coils. (Connectors may optionally be supplied with lights.) Deutsch socket and lead wire also available. Hydraulic/ Electric Shockless: Valve coils available electric shockless (rectified)- reducing voltages spikes, extending relay contact life, and providing even quieter operation. Spool shifting time is increased up to four times by metering the oil in the core tube. Option F (Electrical Box version only) Maintenance: Indicator lamps to diagnose connection; Plug-in coils provide easy changing without disturbing wiring. High Reliability: Valve designed to last 30 million spool shifts under proper use. Bolt Kit included with valve standard *Some spools rated less- check max. pressures and flows chart Specifications Series 35 High Flow/ High Pressure Directional Valves S Electrical Box Type SDS Deutsch Socket SD DIN Type SL Lead Wire Type Note: The maximum flow capacity is shown here. The maximum flow of each valve differs depending on pressure. See HP (Pressure-Flow curve for each model.

Specifications Internal Structure * with Double Loop High Flow Design * @3000psi Viscosity of hydraulic fluid: 150SUS (32mm 2 /s) Symbols

Common 115 VAC Models Common Configurations Symbol Symbol Electrical Box S-1A-115A-35 A S-2H-115A-35 H S-1 - S-5 - S-2 - S-3A- S-1AY-115A-35 AY S-2K-115A-35 K Din Coil S-2B-115A-35 B S-2T-115A-35 T SD-1 - SD-5 - SD-2 - SD-3A- S-2C-115A-35 C S-3A-115A-35 A S-2F-115A-35 F SDS- -12D or 24D Deutsch Connector -SP- -DC Single Spade Connector Example of Code R Reversed (symbols shown in simplified form) SD-2B (standard) SD-2BR (no change to DIN coil valve, electrical box flipped for opposite coil markings) SD-1A (standard) SD-1AR (coil supplied reversed from normal position & spool reversed) SD-5B (standard) SD-5BR (right or b coil side of valve provided) (symbol shown blocked during valve transition only) Pressure Drop Curves

Electrical Information Solenoid Coil Specifications Solenoid Voltage Coil Model S (Elect. Box) Coil Model SD (DIN) Applied Voltage Frequency (Hz) Starting Current (A) Holding Current (A) Holding Power (W) Permissible Voltage Range (V) Insulation Resistance (M ) 115V-AC 2BH-C1/C3 2AH-C1/C3 AC110 AC120 50 60 60 2.2 2.0 2.2 0.54 0.41 0.47 25 22 28 80-120 230V-AC 2BH-C2/C4 2AH-C2/C4 115V-RAC (rectified) 2BF-R1/R3 2AF-R1/R3 AC220 AC240 AC110 AC120 50 60 60 50 / 60 1.1 1.0 1.0 0.25 0.19 0.23 0.31 0.32 25 22 180-240 28 30 32 80-130 100 or above (500V) 230V-RAC (rectified) 2BF-R2/R4 2AF-R2/R4 AC220 AC240 50 / 60 0.15 0.16 30 32 180-250 12V-DC 2BF-D1 2AF-D1 DC12 2.5 30 10.8-13.2 24V-DC 2BF-D2 2AF-D2 DC24 1.25 30 21.6-26.4 Electrical Box Wiring Double Solenoid Single Solenoid Earth Terminal Indicating Light Solenoid (b) Terminal Solenoid (a) Terminal Earth Terminal Indicating Light Solenoid (b) Terminal Solenoid b Solenoid a Solenoid b Solenoid a Common Jumper Common Terminal Indicating Light Earth Terminal Common Terminal Terminal supplied on opposite a side when ordering reversed coil valve (Code R part number) Notes: DIN Coils manufactured to accept standard 3 pin DIN 43 650 and ISO 4400 connectors. AC Coils are rated for both 50/60Hz (rewiring not required) DC coils are not polarity sensitive Rectifier is supplied: in the electrical box- S, in the coil (internal)- SD Hydraulic shockless AC valves are always supplied with rectifier. Hydraulic shockless valves will not operate as shockless until the tank line has become filled with oil- occurs automatically after the first few cycles. Mounting valve below the reservoir oil level or using check valve ensures that the tank line remains filled. Do not supply electrical power to the AC coils unless the coil is mounted on the valve. Do not exceed voltage specifications shown above. Electrical power should be maintained on detented valves (spool code 3A). Detent only maintains start-up position of the valve.

Dimensional Data Electrical Box Type S SF Units: Inches 4.04 4.04 Mounting: (4) 10-24 SHCS x 1-3/4 Torque 40-45 in-lbs 2.60 4.04 1.65 8.07 (2) 1/2 NPT 5.69 DC Solenoid Indicator Light 2.80 1.00 1.87 3.48 0.30 Dia. Indicator Light 1.81 Push pin for manual operation 4.52 1.66 9.04 DIN Type SD 1.88 Units: Inches Mounting: (4) 10-24 SHCS x 1-3/4 Torque 40-45 in-lbs 4.04 5.57 2.60 1.54 4.04 4.04 8.07 DC Solenoid 1.88 3.13 1.00 1.87 3.58 0.30 Dia. 1.81 Push pin for manual operation 4.52 9.04 1.54 Lead Wire Type SL DC Solenoid Units: Inches Mounting: (4) 10-24 SHCS x 1-3/4 Torque 40-45 in-lbs 4.52 1.54 9.04

Parts Breakdown S/ SD/ SL Series 35 Parts Breakdown S/ SD/ SL Series 35 S-2 B-115 A-35 Ordering Information Size Size Code S SD SF SDS Actuator Solenoid Soln. w/ Din Coil Hydraulic Shockless Deutsch Socket ( only) Specify: (special order) SL for Lead Wire SP for Single Spade Plug Thread US Metric 10-24 UNC Code 1 2 3 5 Torque in-lbs/ (Nm) 40-45 (4.5-5.1) Configuration Single solenoid 2 position spring offset Double solenoid 3 position spring centered Double solenoid 2 position no center, detented Single solenoid 2 position spring centered SF All Spools are Open in Transition Mounting Bolt/ O Ring Information O Ring 9mm I.D. x 2mm C.S. Code A AY B C F H K T Spool Function P to A, B to T P to A, B to T All Ports Blocked A & B Blocked P to T A & B to T P Blocked All Ports Open A to T P & B Blocked P to A & B, T Blocked A spool is closed in transition AY spool is open in transition Voltage 12 24 115 230 Current/ Connector A AC D DC Notes: Lights included standard on electrical box style. Code R (reversed) added behind spool code for flow supplied opposite of standard. Codes 1AR & 1AYR: spool & coil reversed Codes 2 R & 3AR: electrical box reversed Code 5 R: coil provided on reversed a side