1 a Nexans company Catalogue 2014
2
3 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of accessories for underground cables: premoulded EPDM rubber connectors for cables and epoxy bushings for transformers and switchgear, as well as a large range of coldshrinkable terminations and joints from to 42 kv. Euromold is also the manufacturer of electrical components for the high voltage accessories of the Nexans group. ISO 9001 Certificate Since 1992, Euromold s commitment to quality is demonstrated by its ISO 9001 certification. International standards All our products meet the International standards like CENELEC HD 629.1, CENELEC EN 50180, IEC 60137, IEC or country specifications. Official certificates, CESI, KEMA, ATEX prove the conformity of our products. Long duration tests of existing or new products are continuously performed in our test fields. Laboratory accreditation Since June 2000, Euromold s independent ELAB laboratory obtained the BELAC accreditation no.144-test conform with the European standards for laboratories ISO for electrical testing of low and medium voltage cable accessories according to the international standards EN 50393, IEC , IEC and HD 629. While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products described in this catalogue as standards and technology evolve. 1
4 EQUIPMENT BUSHINGS Table of contents 180AR-1 - interface A1 bushing 180AR-2 - interface A1 bushing 180AR-3 - interface A1 bushing 250SFR-P - interface A1 bushing 180A-P-O - interface A1 in-air bushing 400T1 - interface B2 bushing 400AR-1 - interface B2 bushing 400AR-2 - interface B2 bushing 400AR-8 - interface B1 bushing 400SFR-P - interface B2 bushing 400AR-3 - interface C1 bushing 400AR-4 - interface C2 bushing 400AR-5 - interface C2 bushing 400AR-6 - interface C1 bushing 400SFR-B - interface C1 & C2 bushing 400A-B - interface C1 in-air bushing 670AR-2 - interface D2 bushing 900AR-1 - interface F3 bushing 900AR-2 - interface F2 bushing 900AR-3 - interface F1 bushing 900AR-4 - interface F1 bushing 2
5 Dimensions These diagrams show the dimensions of the interfaces of bushings according to CENELEC standards EN 50180:2010 and EN 50181:2010. Dia. 56 ±0.2 Dia. 46 ±0.2 DIMENSIONS & RATINGS OF EQUIPMENT BUSHINGS Dia. for pin Dia. 56 ±0.2 Dia. 46 ±0.2 Dia. 22 min for C1 Dia. 32 nominal for C2 M16 x 2-6H Dia ±0.2 Dia Dia. for pin min 29 min 90 ± ± min Dia ± min 11 min Interface A1 Dia. 70 ±0.2 Interface B1 & B2 Dia. 70 ±0.2 Interface C1 & C2 Dia ±0.2 Dia ±0.2 Dia ±0.2 Dia. 32 nominal M16 x 2-6H Dia. 64 ±0.2 M16 x 2-6H Dia. 50 min for F1 Dia. 22 nominal for F2 Dia. 32 nominal for F min 29 min 81 ± ± min Short circuit ratings Dia ±0.2 Interface D1 & D2 Interface F1, F2 & F3 Interface type Contact type Current rating (A) RMS symm. (ka) 1 sec. 2 sec. 3 sec. Peak asymm. (ka) A1 B1 B2 C1 C2 D1 D2 F1 F2 F3 Pin and socket Pin and socket Pin and socket Bolted Bolted Bolted Bolted Bolted Bolted Bolted >150 5 > >150 3
6 180AR-1 /180AR-2 /180AR-3 INTERFACE A1 EQUIPMENT BUSHINGS Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Specifications and standards The plug-in type bushings 180AR- meet the requirements of CENELEC EN and IEC Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The bushings are moulded epoxy insulated parts in accordance with CENELEC EN The 180AR-2 bushing has a length B outside this standard. The standard bushings, (K)180AR-1 /-2 /-3, are equipped with 6 tabs for the bail restraint. The (K)180AR-1-G and (K)180AR-3-G are equipped with 4 tabs and 2 threaded inserts M6 (-G version). Type 180AR-1-G /-3-G Type 180AR-1 /-2 /-3 M A Ordering instructions To order the bushing, specify the type. The bushings are supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. K180AR-1/J. Minimum oil level: - kv: 40 mm - kv: 50 mm Dia. 16 Dia. 75 Dia. 110 M10 B 19 Equipment bushing type Voltage Um (kv) Current Ir (A) A Dimensions (mm) B 180AR-1 K180AR-1 180AR-2 K180AR-2 180AR-3 K180AR
7 180AR-1/GS 180AR-1-G/GS 180AR-2/GS 180AR-3/GS and 180AR-3-G/GS Bushings FIXINGS FOR EQUIPMENT BUSHINGS 180AR-1/J 180AR-1-G/J 180AR-2/J 180AR-3/J and 180AR-3-G/J Bushings bushing interface fixing studs NF C clamp E DIN stud clamp sealing gasket tabs for bail restraint A DIN fixing flange earth plate earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC standards, simply specify KBCNF Contents: - 3 x claw clamp NF200-1 x sealing gasket. standards NF C French standards. M8 or M10 M10 Bushing clamping kit To order the bushing clamping kit, according to DIN standards, simply specify: KBCD-200. Contents: - 1 x fixing flange A - 4 x stud clamp E - 1 x sealing gasket. standards DIN German standards. Min. 55 Max. 30 Min. 55 Max fixing studs Dia. 78 Dia. 6 4 fixing studs Dia. 78 Dia. 3 5
8 Application For use in insulated with SF 6 gas. Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 250SFR-P INTERFACE A1 EQUIPMENT BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Design The bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN The 250SFR-P bushing has a shank outside this standard, adapted to use in SF 6 gas. Dia. 70 Dia Specifications and standards The plug-in type bushings 250SFR-P meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, simply specify the type. Dia. 70 Dia. 109 M10 Dia. 20 Equipment bushing type Voltage Um (kv) Current Ir (A) 250SFR-P K250SFR-P
9 FIXINGS FOR EQUIPMENT BUSHINGS 250SFR-P Bushing for gas insulated switchgear UNMOUNTED 60 earth M M6 Dia Dia Dia. 4 MOUNTED bail tab sealing O-ring gasket 6 fixing screws M6 earth M4 7
10 Application For use in insulated with air, typically for dry type transformers, motors, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 180A-P-O INTERFACE A1 IN-AIR BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Specifications and standards The plug-in type bushings 180A-P-O are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50181, IEC and IEC Dia A Dia. 110 Ordering instructions To order the bushing, specify the type. The bushings are supplied with an earth jumper. To include the ring clamp, add: /B, if per British standards /D, if per German standards /F, if per French standards. E.g. 180A-P-O/F Dia B Dia. 80 M10 Equipment bushing type Voltage Um (kv) Current Ir (A) Creepage distance A-B (mm) 180A-P-O 180A-P-O
11 180A-P-O In-air bushing bushing interface fixing studs and nuts M10 earth jumper FIXINGS FOR EQUIPMENT BUSHINGS gasket fixing flange BCA-B or BCA-D fixing flange BCA-F tabs for bail restraint Dia Dia. 10 Dia. 10 Dia Dia. 111 Dia F 6 BS 2562 stand.: 0 DIN stand.: 3 Dia. 150 Type BCA-B : BS 2562 British standards Type BCA-D : DIN German standards standards DIN German standards. 0 Dia. 150 Type BCA-F : NFC French standards standards NF C French standards. M10 M10 Min. 55 Max. 20 Min. 55 Max fixing studs 3 fixing studs Dia. 82 Dia. 3 Dia. 82 Dia. 6 9
12 400T1 /400AR-1 /400AR-2 INTERFACE B2 EQUIPMENT BUSHINGS Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv 19/33 () kv Specifications and standards The plug-in type bushings are moulded epoxy insulated parts and meet the requirements of IEC The (K)(M)400T1 also meets CENELEC EN C Ordering instructions To order the bushing, specify the type. The bushings are supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. K400AR-1/J. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 75 mm Dia. H B A E Dia. 70 Dia. F Dia. G D Equipment bushing type Voltage Um (kv) Current Ir (A) Dimensions (mm) A B C D E Dia. F Dia. G Dia. H 400T1 K400T1 M400T1 400AR-1 K400AR-1 M400AR-1 400AR-2 K400AR-2 M400AR M M M M M M M16 M16 M
13 400AR-2/GS Bushing 400AR-2/J Bushing FIXINGS FOR EQUIPMENT BUSHINGS 400AR-1/J and 400T1/J Bushings bushing interface fixing studs bushing interface fixing studs NF C claw clamp fixing flange F DIN stud clamp fixing flange B DIN E DIN stud clamp sealing gasket sealing gasket tabs for the bail restraint tabs for the bail restraint earth plate earth jumper earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC standards, simply specify KBCNF-400 (for bushing type 400AR-2). Contents: - 4 x claw clamp NF400-1 x sealing gasket. standards NF C French standards. Bushing clamping kit To order the bushing clamping kit, simply specify: KBCDS- 400B. Contents: - 1 x fixing flange - 6 x stud clamp F - 1 x sealing gasket. Bushing clamping kit To order the bushing clamping kit, according to DIN standards, simply specify KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. standards DIN German standards. M10 or M M M10 Min. 55 Max. 25 Min. 60 Max. 30 Min. 55 Max fixing studs Dia. 105 Dia fixing studs Dia. 105 Dia fixing studs Dia. 90 Dia
14 Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-8 INTERFACE B1 EQUIPMENT BUSHING Up to kv A 6/10 () kv 6,35/11 () kv 8,7/15 (17,5) kv /20 () kv,7/22 () kv 18/30 () kv Specifications and standards The plug-in type bushings 400AR-8 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, specify the type. The bushings can be supplied with an earth jumper (/J). E.g. M400AR-8/J. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 75 mm Dia M10 Dia. 74 Dia. 110 Equipment bushing type Voltage Um (kv) Current Ir (A) 400AR-8 K400AR-8 M400AR
15 FIXINGS FOR EQUIPMENT BUSHINGS 400AR-8/J Bushing bushing interface 4 x fixing stud M10 Bushing clamping kit To order the bushing clamping kit, according to DIN standards, simply specify: KBCD-200. Contents: - 1 x fixing flange A - 4 x stud clamp E - 1 x sealing gasket. A DIN fixing flange E DIN stud clamp sealing gasket standards DIN German standards. tabs for the bail restraint M10 Min. 55 Max. 30 earth jumper 4 fixing studs Dia. 78 Dia. 3 13
16 Application For use in insulated with SF 6 gas. Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400SFR-P INTERFACE B2 EQUIPMENT BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv 19/33 () KV Design The bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN The 400SFR-P bushing has a shank outside this standard, adapted for use in SF 6 gas. Dia. 70 Specifications and standards The plug-in type bushing 400SFR-P meets the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, simply specify the type. Dia. 25 Dia. 70 Dia. 109 M Equipment bushing type Voltage Um (kv) Current Ir (A) 400SFR-P K400SFR-P M400SFR-P
17 FIXINGS FOR EQUIPMENT BUSHINGS 400SFR-P Bushing for gas insulated switchgear UNMOUNTED 60 earth M M6 Dia Dia Dia. 4 MOUNTED 97.5 Dia. 100 bail tab sealing O-ring gasket 6 fixing screws M6 earth M4 15
18 Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-3 INTERFACE C1 EQUIPMENT BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv 19/33 () kv Specifications and standards The bolted type bushings 400AR-3 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, specify the type. The bushings can be supplied with an earth jumper (/J). E.g. M400AR-3/J. For use in potentially explosive atmospheres (for kv max), order: 400AR-3/ATEX. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 75 mm Dia M16 Dia. 70 Dia. 88 Dia. 8 Equipment bushing type Voltage Um (kv) Current Ir (A) 400AR-3 K400AR-3 M400AR
19 FIXINGS FOR EQUIPMENT BUSHINGS 400AR-3/J Bushing bushing interface fixing studs Bushing clamping kit To order the bushing clamping kit, according to DIN standards, simply specify KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. fixing flange B DIN E DIN stud clamp sealing gasket standards DIN German standards. M10 Min. 55 Max fixing studs Dia. 90 Dia. 140 earth jumper 17
20 Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-4 INTERFACE C2 EQUIPMENT BUSHING Up to kv - 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv 19/33 () kv Specifications and standards The bolted type bushings 400AR-4 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, specify the type. The bushings can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. M400AR-4/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 75 mm Dia M16 Dia. 70 Dia. 100 Dia. 150 Equipment bushing type Voltage Um (kv) Current Ir (A) 400AR-4 K400AR-4 M400AR
21 400AR-4/GS Bushing FIXINGS FOR EQUIPMENT BUSHINGS 400AR-4/J Bushing bushing interface fixing studs fixing flange NF C claw clamp F DIN stud clamp sealing gasket earth plate earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC standards, simply specify KBCNF-400. Contents: - 4 x claw clamp NF400-1 x sealing gasket. standards NF C French standards. Bushing clamping kit To order the bushing clamping kit with DIN style fixing flange, simply specify KBCDS-400. Contents: - 1 x fixing flange DIN style - 6 x stud clamp F DIN x sealing gasket. M10 or M M Min. 55 Max. 25 Min. 60 Max fixing studs Dia. 105 Dia fixing studs Dia. 105 Dia
22 Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-5 INTERFACE C2 EQUIPMENT BUSHING Up to kv - 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv Specifications and standards The bolted type bushings 400AR-5 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, specify the type. The bushings can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. M400AR-5/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 70 mm Dia M16 Dia. 76 Dia. 150 Equipment bushing type Voltage Um (kv) Current Ir (A) 400AR-5 K400AR-5 M400AR
23 FIXINGS FOR EQUIPMENT BUSHINGS 400AR-5/GS Bushing 400AR-5/J Bushing bushing interface fixing studs NF C claw clamp sealing gasket fixing flange F DIN stud clamp earth plate earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC standards, simply specify KBCNF-400. Contents: - 4 x claw clamp NF400-1 x sealing gasket. standards NF C French standards. Bushing clamping kit To order the bushing clamping kit with DIN style fixing flange, simply specify KBCDS-400. Contents: - 1 x fixing flange DIN style - 6 x stud clamp F DIN x sealing gasket. M10 or M M Min. 55 Max. 25 Min. 60 Max fixing studs Dia. 105 Dia fixing studs Dia. 105 Dia
24 Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400AR-6 INTERFACE C1 EQUIPMENT BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv 19/33 () kv Specifications and standards The bolted type bushings 400AR-6 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, specify the type. The bushings can be supplied with an earth jumper (/J). This earth must be specified when ordering. E.g. M400AR-6/J Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 75 mm Dia Dia. 70 Dia. 74 Dia. 8 M16 Equipment bushing type Voltage Um (kv) Current Ir (A) 400AR-6 K400AR-6 M400AR
25 FIXINGS FOR EQUIPMENT BUSHINGS 400AR-6/J Bushing fixing studs fixing flange B DIN E DIN stud clamp bushing interface sealing gasket Bushing clamping kit To order the bushing clamping kit, according to DIN standards, simply specify KBCD-400B. Contents: - 1 x fixing flange B - 6 x stud clamp E - 1 x sealing gasket. standards DIN German standards. M10 Min. 55 Max fixing studs Dia. 80 Dia. 140 earth jumper 23
26 Application For use in insulated with SF 6 gas. Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400SFR-B INTERFACE C1 & C2 EQUIPMENT BUSHING Up to kv 630 A & 50 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv 19/33 () kv Design The bushing is a moulded epoxy insulated part with a connector interface in accordance with CENELEC EN The 400SFR-B bushing has a shank outside this standard, adapted to use in SF 6 gas. Dia Specifications and standards The bolted type bushing 400SFR-B meets the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, simply specify the type. M Dia. D Dia. 70 Dia. 109 Equipment bushing type Voltage Um (kv) Interface Current Ir (A) Dia. D (mm) 400SFR-B K400SFR-B M400SFR-B 400SFR-B 50 A K400SFR-B 50 A M400SFR-B 50 A C1 C1 C1 C2 C2 C
27 FIXINGS FOR EQUIPMENT BUSHINGS 400SFR-B Bushing for gas insulated switchgear UNMOUNTED 60 earth M M6 Dia Dia MOUNTED bushing interface 6 fixing screws M6 sealing O-ring gasket earth M4 25
28 Application For use in insulated with air, typically for dry type transformers, motors, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 400A-B INTERFACE C1 IN-AIR BUSHING Up to kv A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv Specifications and standards The bolted type bushings 400A-B are moulded epoxy insulated parts and meet the requirements of CENELEC EN 50180, IEC and IEC Ordering instructions To order the bushing, specify the type. The bushings are supplied with an earth jumper. To include the ring clamp, add: /B, if per British standards /D, if per German standards /F, if per French standards. E.g. 400A-B/D. For use in potentially explosive atmospheres (for kv max), order: -/ATEX. A Dia. 80 Dia. 110 Dia B Dia. 80 M16 Equipment bushing type Voltage Um (kv) Current Ir (A) Creepage distance A-B (mm) 400A-B 400A-B
29 400A-B In-air bushing FIXINGS FOR EQUIPMENT BUSHINGS bushing interface fixing studs and nuts M10 earth jumper gasket fixing flange BCA-B or BCA-D fixing flange BCA-F Dia Dia. 111 Dia. 10 Dia. 10 Dia Dia F 6 BS 2562 stand.: 0 DIN stand.: 3 Dia. 150 Type BCA-B : BS 2562 British standards Type BCA-D : DIN German standards 0 Dia. 150 Type BCA-F : NFC French standards standards DIN German standards. standards NF C French standards. M10 M10 Min. 55 Max. 20 Min. 55 Max fixing studs 3 fixing studs Dia. 82 Dia. 3 Dia. 82 Dia. 6 27
30 670AR-2 INTERFACE D2 EQUIPMENT BUSHING Application For use in insulated with oil fluid, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. Up to kv - 50 A 6/10 () kv 6,35/11 () kv 8,7/15 (17,5) kv /20 () kv.7/22 () kv Specifications and standards The bolted type bushings 670AR-2 are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, specify the type. The bushings can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. K670AR-2/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm Dia Dia. 70 Dia. 100 Dia. 150 M16 Equipment bushing type Voltage Um (kv) Current Ir (A) 670AR-2 K670AR
31 670AR-2/GS Bushing FIXINGS FOR EQUIPMENT BUSHINGS 670AR-2/J Bushing bushing interface fixing studs fixing flange NF C claw clamp F DIN stud clamp sealing gasket earth jumper earth plate Bushing clamping kit To order the bushing clamping kit, according to NFC standards, simply specify KBCNF-400. Contents: - 4 x claw clamp NF400-1 x sealing gasket. standards NF C French standards. Bushing clamping kit To order the bushing clamping kit with DIN style fixing flange, simply specify KBCDS-400. Contents: - 1 x fixing flange DIN style - 6 x stud clamp F DIN x sealing gasket. M10 or M M Min. 55 Max. 25 Min. 60 Max fixing studs Dia. 105 Dia fixing studs Dia. 105 Dia
32 Application For use in, typically for transformers, switchgear, capacitors... Technical characteristics Each bushing is tested for AC withstand and partial discharge prior to leaving the factory. 900AR-1 / 900AR-2 900AR-3 / 900AR-4 INTERFACE F1, F2 & F3 EQUIPMENT BUSHING Up to 52 kv Up to 2500 A 6/10 () kv 6.35/11 () kv 8.7/15 (17.5) kv /20 () kv.7/22 () kv 18/30 () kv 19/33 () kv 20.8/ (42) kv 26/45 (52) kv Specifications and standards The bolted type bushings 900AR-X are moulded epoxy insulated parts and meet the requirements of CENELEC EN and IEC Ordering instructions To order the bushing, specify the type. Add a 'K' for use up to kv, add an 'M' for use up to kv, add a 'P' for use up to 42 kv, add a 'Q' for use up to 52 kv. The bushings can be supplied with an earth jumper (/J) or an earth plate (/GS). This earth must be specified when ordering. E.g. 900AR-4/GS. Minimum oil level: - kv: 40 mm - kv: 50 mm - kv: 75 mm -42 kv: 0 mm -52 kv: 175 mm Dia. C B 40 A Dia. 100 Dia. 150 M16 Equipment bushing type Interface type Voltage Um (kv) Current Ir (A) Dimensions (mm) A B Dia. C 900AR-1 900AR-2 900AR-3 900AR-4 F3 F2 F1 F
33 900AR-X/GS Bushing FIXINGS FOR EQUIPMENT BUSHINGS 900AR-X/J Bushing bushing interface fixing studs fixing flange NF C claw clamp 400/630 series F DIN stud clamp sealing gasket earth plate earth jumper Bushing clamping kit To order the bushing clamping kit, according to NFC standards, simply specify KBCNF-400. Contents: - 4 x claw clamp NF400-1 x sealing gasket. standards NF C French standards. Bushing clamping kit To order the bushing clamping kit with DIN style fixing flange, simply specify KBCDS-400. Contents: - 1 x fixing flange DIN style - 6 x stud clamp F DIN x sealing gasket. M10 or M Min. 55 Max fixing studs Dia Dia
34 NOTES 32
35
36 Additional catalogue information on power cable accessories is available by contacting us at the address below: Distributed by: a Nexans company Nexans Network Solutions N.V. - Div. Euromold Zuid III, Industrielaan, B-9320 Erembodegem Tel.: +32 (0) sales.euromold@nexans.com Catalogue also available on CD-ROM, website and Mobile Apps
a Nexans company Catalogue 2013
a Nexans company Catalogue 03 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationa Nexans company Catalogue 2015
a Nexans company Catalogue 2015 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated
More informationCompact catalogue 2014/2015
Compact catalogue 20/20 Nexans Power Accessories Germany GmbH Technical instructions and application information The data given were determined diligently, but do not release our customers of the duty
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationTransformer Bushings for GIS
Transformer Bushings for GIS Oil to SF6 Connections GARIP RTKG 725-55 kv SQS certified ISO 91 / ISO 141 Bushings RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is
More information1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide
1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible
More informationEDITION 2012 CABLE SYSTEMS
EDITION 2012 CABLE SYSTEMS Cable fittings for high voltage networks Welcome to the CABLE SYSTEMS Centre of Competence. Our range of cable accessories offers solutions for virtually all applications in
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More information4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
More informationCABLE ACCESSORIES 110-220 kv
CABLE ACCESSORIES 110-220 kv Termination 110 kv Technical description Termination MKB 126 / 145 with composite type insulator uses for cable line joints with other elements of power-supply systems. Termination
More informationMiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003
MiCAFIL 1 RIP Technology Z. Zic 09/2003 )XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field %XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU
More informationLV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationTakfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal. www.takfanmakina.com.tr
www.takfanmakina.com.tr Plug in Bushing LV Monoblock RMU Bushing 4 Way CT Terminal Solution Partner of Medium Voltage Insulation and Epoxy Casting Design *Medium voltage Switching Equipments Design *Load
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationMETAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationSITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
More informationISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24
Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical
More informationHow To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
More informationCable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13
Cable Accessories for Extruded Dielectric Cable 69kV - 230kV Rated Components used in cable systems 100% Tested Factory Molded For outdoor applications through 230kV For gas insulated substations and transformers
More information400 Series Buccaneer BUCCANEER POWER. bulgin
bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationInstructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
More informationKOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
More information1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide
1ZSC000563-AAC en, Rev. 7 Resin impregnated paper bushing, oil to air, type GSB Technical guide Original instruction The information provided in this document is intended to be general and does not cover
More informationLine-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationModel 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
More information25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp
Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal
More information10 2161.002201 2161.002401 slide flange. 11 2161.001295 2161.001296 slide ring
spareparts list sparepart part No. code No. GP 40 GP 50 shaft seal 10 2161.002201 2161.002401 slide flange 11 2161.001295 2161.001296 slide ring 12 2161.001226 2161.001265 O-ring 13 5642.ABBR01 5642.ABCD01
More informationExplosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
More informationIEC Connectors. Introduction
Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings
More informationVDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials
VDE Information General Information The voltage which can be applied to a terminal depends on the relevant regulations, the installation conditions and, of course, the dimensions and insulating materials
More informationOLI. Oil level indicator
OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationLOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS
Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationproduces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.
www.ppcinsulators.com The very Best. The very Best. That s what we deliver. ong od Insulators Only a company that develops, produces and delivers products worldwide can provide the optimal solution for
More information08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationSolenoid Operated Directional Valves
INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationkymanual or Automatic - it s your Choice
. kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationKAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System
2-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / E-LINE KX Compact Busbar Distribution System 63...63 A E-LINE KB Compact Busbar Distribution System 8...63 A E-LINE KO Plug-in
More informationMetal Clad Indoor Instrument Transformer for Plug-In Systems
Metal Clad Indoor Instrument Transformer for Plug-In Systems RITZ Instrument Transformers GmbH Core competency Under the trading name RITZ Instrument Transformers GmbH RITZ has been pooling its activities
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationToroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationNo: 898501 En Revision 02 2009.08. Parts List. MINEX 8101.171 100-110 222 200-21 3
No: 89850 En Revision 02 2009.08 Parts List MINEX 80.7 www.grindex.com 2 3 6 3 5 00-0 7 8 9 5 6 7 20 2 22 6 8 9 0 2 3 5 20 2 22 23 23 2 25 26 27 7 8 9 50 5 52 53 5 220 22 222 200-2 3 55 56 57 28 58 59
More informationMedium voltage insulator
Medium voltage insulator Line post insulators type R-ET Commercial designation LPI 24 N ET 1) LPI 24 L ET/5 1)2) LPI 24 L ET/6 1)2) LPI 38 L ET 1) esignation acc. to IEC 720 R 12,5 ET 125 N R 12,5 ET 125
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More informationFuse Selection Method Module 2. Date of the presentation
Fuse Selection Method Module 2 Date of the presentation Fuse Selection When selecting LV fuses certain important information must be known. 1.System Voltage This is the voltage of the system or distribution
More informationRPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
More informationALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationNATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationMedium voltage product. Instrument transformers for indoor applications Product overview
Medium voltage product Instrument transformers for indoor applications Product overview 02 Contents Introduction Current transformers Supporting type 6 TPU, TPE 7 KOFA, IHBF 10 Dummy Bus type 8 KOKS 12,
More informationMedium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
More informationA Division Of AVX Corporation. DIN Connectors
A Division Of AVX Corporation DIN Connectors Index by DIN Style Introduction & Applications 4 Press-Fit 7 Design Aids 8 Approvals 8 Technical Specifications 11 Plating 12 Military Cross Reference 12 STYLE
More informationThe Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationvacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall-mounted drives
vacon 100 vacon 100 flow vacon 100 hvac ac drives installation manual wall-mounted drives PREFACE VACON 3 PREFACE Document ID: DPD01711F Date: 8.7.2015 ABOUT THIS MANUAL This manual is copyright of Vacon
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationTechnical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
More informationSurge protection for emergency alarm systems
Surge protection for emergency alarm systems White Paper Contents Lightning and surge protection for a burglar alarm system with pulse polling technology Lightning and surge protection for a fire alarm
More informationPremolded cable termination, indoors SOT 7.2 kv
Premolded cable termination, indoors SOT 7. kv cables 1- or 3-core with Al or Cu conductor for 6.6/7. kv, indoors. t can also be installed in an indoor humid environment*. s CENELEC, HD 69.1 S1 integrated
More informationSolenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
More informationPSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS
PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS AC AND DC GENERATOR SCHEMATIC ENGINE GENERATOR ASSEMBLY REF Description QTY PSS10 PSS12 1 Engine, Honda GX620K1VXC2 Code 637220 1 99779-000 GX670VXC2 Code 637220
More informationReaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationGISMA UNDERWATER CONNECTORS SERIES 40
CONTENTS SEITE / PAGE GENERAL 4 GENERAL ARRANGEMENT 5 DESIGN MECHANICAL FEATURES 7 FIBRE OPTIC FEATURS 7 ELECTRICAL FEATURES 7 REFERENCE SYSTEM 8 REFERENCE SYSTEM CONTACTS 9 CONTACT LAYOUTS 9 SUGGESTIONS
More informationOutdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
More informationMounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationLife Expectancy : Class A Class B Class C Class D 30,000hrs 10,000hrs 3,000hrs 1000hrs
3.2 Motor Run Capacitors : continuous operation ypical Applications : Motor Run Capacitor ideal for various motor applications in washing machine, air conditioner, electric water pump, power factor collection
More informationUniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationGlenair Military and Industrial Power and Signal Connectors
Glenair Military and Industrial Power and Signal Connectors Series ITS (And FRITS) 5015 Type Reverse Bayonet Connectors Derived from MIL-DTL-5015 and VG95234 Mating mechanism (3 reverse bayonets at 120
More information7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
More informationSealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
More informationKTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429