Chapter 6: Converter circuits



Similar documents
The Flyback Converter

Power supplies. EE328 Power Electronics Assoc. Prof. Dr. Mutlu BOZTEPE Ege University, Dept. of E&E

Chapter 17 The Ideal Rectifier

Current Ripple Factor of a Buck Converter

98% Efficient Single-Stage AC/DC Converter Topologies

DC-DC Converter Basics

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Introduction to Power Supplies

Power Electronic Circuits

Chapter 20 Quasi-Resonant Converters

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Chapter 14: Inductor design

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

The full wave rectifier consists of two diodes and a resister as shown in Figure

DC-DC Power Converters

Chapter 11 Current Programmed Control

Chapter 4. LLC Resonant Converter

Switched Mode Power Supplies

Lecture - 4 Diode Rectifier Circuits

A NEW TWO SWITCH TOPOLOGY BUCK BOOST CONVERTOR IN UNIVERSAL INPUT PFC APPLICATION

Chapter 19 Resonant Conversion

Bridgeless PFC Implementation Using One Cycle Control Technique

Welcome to this presentation on Switch Mode Drivers, part of OSRAM Opto Semiconductors LED Fundamentals series. In this presentation we will look at:

Boundary between CCM and DCM in DC/DC PWM Converters

EMI and t Layout Fundamentals for Switched-Mode Circuits

The leakage inductance of the power transformer

Fairchild On-Line Design Tool: Power Supply WebDesigner Step-by-Step Guide

Analog & Digital Electronics Course No: PH-218

Design of an Auxiliary Power Distribution Network for an Electric Vehicle

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Three-port DC-DC Converters to Interface Renewable Energy Sources with Bi-directional Load and Energy Storage Ports

Line Reactors and AC Drives

HIGH FREQUENCY POWER CONVERTERS. Authors: Rudy Severns, Springtime Enterprises Hal Wittlinger, Intersil Semiconductor

A Zero-Voltage Switching Two-Inductor Boost Converter With an Auxiliary Transformer

Which is the best PFC stage for a 1kW application?

EE 221 Circuits II. Chapter 13 Magnetically Coupled Circuits

Application Note AN- 1095

Application Report SLVA057

Power supply output voltages are dropping with each

AND8147/D. An Innovative Approach to Achieving Single Stage PFC and Step-Down Conversion for Distributive Systems APPLICATION NOTE

The D.C Power Supply

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Properties of electrical signals

Topic 5. An Interleaved PFC Preregulator for High-Power Converters

Hybrid Power System with A Two-Input Power Converter

Chapter 15: Transformer design

Development of High Frequency Link Direct DC to AC Converters for Solid Oxide Fuel Cells (SOFC)

CYCLOCONVERTERS. Fig.1 Block diagram of a cycloconverter

Keywords: input noise, output noise, step down converters, buck converters, MAX1653EVKit

Parametric variation analysis of CUK converter for constant voltage applications

Designers Series XII. Switching Power Magazine. Copyright 2005

Rectifier circuits & DC power supplies

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

Semiconductor Diode. It has already been discussed in the previous chapter that a pn junction conducts current easily. Principles of Electronics

High Performance ZVS Buck Regulator Removes Barriers To Increased Power Throughput In Wide Input Range Point-Of-Load Applications

DRIVE CIRCUITS FOR POWER MOSFETs AND IGBTs

MAS.836 HOW TO BIAS AN OP-AMP

ELECTRONIC POWER SYSTEMS

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

SWITCHING REGULATORS

Capacitor Ripple Current Improvements

Implementation of High Step-Up Solar Power Optimizer for DC Micro Grid Application

Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391

Switch Mode Power Supply Topologies

CHAPTER 2B: DIODE AND APPLICATIONS. D.Wilcher

Power Supplies. 1.0 Power Supply Basics. Module

When the Power Fails: Designing for a Smart Meter s Last Gasp

Single-Stage High Power Factor Flyback for LED Lighting

Operational Amplifier - IC 741

High Intensify Interleaved Converter for Renewable Energy Resources

electronics fundamentals

Evaluating AC Current Sensor Options for Power Delivery Systems

Drive circuit basics + V. τ e. Industrial Circuits Application Note. Winding resistance and inductance

High-Efficiency Power Conversion for Renewable Energy and Distribution Generation

National Semiconductor Power Products - Seminar 3 (LED Lighting)

AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION

AN100. The Elusive Tapped Output Inductor. By Colonel Wm. T. McLyman

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

Design Considerations for an LLC Resonant Converter

Design A High Performance Buck or Boost Converter With Si9165

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

Application Notes. Magnetics. Determining L min for Buck/Boost Converters

Chapter 3. Diodes and Applications. Introduction [5], [6]

Design, Analysis, and Implementation of Solar Power Optimizer for DC Distribution System

4. ACTIVE-CLAMP BOOST AS AN ISOLATED PFC FRONT-END CONVERTER

Chapter 1 dc-dc and regulation theory. Chapter 2 Small-signal theory

Magnetics in Switched-Mode Power Supplies

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

Application Report SLVA061

Basic Electronics Prof. Dr. Chitralekha Mahanta Department of Electronics and Communication Engineering Indian Institute of Technology, Guwahati

SPI-8001TW. Switching Regulators. Dual 1.5 A, DC/DC Step-Down Converter. SANKEN ELECTRIC CO., LTD.

Chapter 2 MENJANA MINDA KREATIF DAN INOVATIF

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Planar versus conventional transformer

3-Phase Synchronous PWM Controller IC Provides an Integrated Solution for Intel VRM 9.0 Design Guidelines

Power Electronics. Alberto Tibaldi. July 13, 2010

International Journal of Science and Research (IJSR) ISSN (Online): Index Copernicus Value (2013): 6.14 Impact Factor (2014): 5.

= V peak 2 = 0.707V peak

Modeling Grid Connection for Solar and Wind Energy

Transcription:

Chapter 6. Converter Circuits 6.. Circuit manipulations 6.2. A short list of converters 6.3. Transformer isolation 6.4. Converter evaluation and design 6.5. Summary of key points Where do the boost, buck-boost, and other converters originate? How can we obtain a converter having given desired properties? What converters are possible? How can we obtain transformer isolation in a converter? For a given application, which converter is best?

6.. Circuit manipulations L 2 C R Begin with buck converter: derived in chapter from first principles Switch changes dc component, low-pass filter removes switching harmonics Conversion ratio is M = D 2

6... Inversion of source and load Interchange power input and output ports of a converter Buck converter example 2 = D port port 2 L 2 2 Power flow 3

Inversion of source and load Interchange power source and load: port port 2 L 2 2 Power flow 2 = D = D 2 4

Realization of switches as in chapter 4 Reversal of power flow requires new realization of switches Transistor conducts when switch is in position 2 Interchange of D and D port port 2 2 Power flow L = D' 2 Inversion of buck converter yields boost converter 5

6..2. Cascade connection of converters converter converter 2 = M (D) = M 2 (D) D = M (D) g = M(D)=M (D)M 2 (D) = M 2 (D) 6

Example: buck cascaded by boost L L 2 2 2 C C 2 R { { Buck converter Boost converter = D = D = D D 7

Buck cascaded by boost: simplification of internal filter remove capacitor C L L 2 2 2 C 2 R combine inductors L and L 2 2 L i L 2 Noninverting buck-boost converter 8

Noninverting buck-boost converter L i L 2 2 subinterval subinterval 2 i L i L 9

Reversal of output voltage polarity subinterval subinterval 2 noninverting buck-boost i L i L inverting buck-boost i L i L 0

Reduction of number of switches: inverting buck-boost subinterval subinterval 2 i L i L One side of inductor always connected to ground hence, only one SPDT switch needed: 2 i L = D g D

Discussion: cascade connections Properties of buck-boost converter follow from its derivation as buck cascaded by boost Equivalent circuit model: buck :D transformer cascaded by boost D : transformer Pulsating input current of buck converter Pulsating output current of boost converter Other cascade connections are possible Cuk converter: boost cascaded by buck 2

6..3. Rotation of three-terminal cell Treat inductor and SPDT switch as threeterminal cell: three-terminal cell A a b B c C 2 v Three-terminal cell can be connected between source and load in three nontrivial distinct ways: a-a b-b c-c a-c b-a c-b a-a b-c c-b buck converter boost converter buck-boost converter 3

Rotation of a dual three-terminal network A capacitor and SPDT switch as a threeterminal cell: A a three-terminal cell b B 2 c v C Three-terminal cell can be connected between source and load in three nontrivial distinct ways: a-a b-b c-c a-c b-a c-b a-a b-c c-b buck converter with L-C input filter boost converter with L-C output filter Cuk converter 4

6..4. Differential connection of load to obtain bipolar output voltage dc source load converter = M(D) D converter 2 2 Differential load voltage is = 2 The outputs and 2 may both be positive, but the differential output voltage can be positive or negative. 2 = M(D') D' 5

Buck converter } Differential connection using two buck converters 2 2 Converter # transistor driven with duty cycle D Converter #2 transistor driven with duty cycle complement D Differential load voltage is = D D' 2 Simplify: Buck converter 2{ =(2D) 6

Conversion ratio M(D), differentially-connected buck converters M(D) =(2D) 0 0.5 D 7

Buck converter } Simplification of filter circuit, differentially-connected buck converters Original circuit Bypass load directly with capacitor 2 2 2 2 2 Buck converter 2{ 8

Simplification of filter circuit, differentially-connected buck converters Combine series-connected inductors 2 Re-draw for clarity L g 2 i L C R 2 2 H-bridge, or bridge inverter Commonly used in single-phase inverter applications and in servo amplifier applications 9

Differential connection to obtain 3ø inverter dc source converter 3øac load With balanced 3ø load, neutral voltage is = M(D ) n = 3 ( 2 3 ) D converter 2 2 = M(D 2 ) 2 v bn v an v cn n Phase voltages are an = n bn = 2 n cn = 3 n D 2 converter 3 3 = M(D 3 ) D 3 3 Control converters such that their output voltages contain the same dc biases. This dc bias will appear at the neutral point n. It then cancels out, so phase voltages contain no dc bias. 20

3ø differential connection of three buck converters dc source 3øac load v an 2 v bn n v cn 3 2

3ø differential connection of three buck converters Re-draw for clarity: dc source 3øac load v an v bn v cn n oltage-source inverter or buck-derived three-phase inverter 22

6.2. A short list of converters An infinite number of converters are possible, which contain switches embedded in a network of inductors and capacitors Two simple classes of converters are listed here: Single-input single-output converters containing a single inductor. The switching period is divided into two subintervals. This class contains eight converters. Single-input single-output converters containing two inductors. The switching period is divided into two subintervals. Several of the more interesting members of this class are listed. 23

Single-input single-output converters containing one inductor Use switches to connect inductor between source and load, in one manner during first subinterval and in another during second subinterval There are a limited number of ways to do this, so all possible combinations can be found After elimination of degenerate and redundant cases, eight converters are found: dc-dc converters buck boost buck-boost noninverting buck-boost dc-ac converters bridge ac-dc converters current-fed bridge Watkins-Johnson inverse of Watkins-Johnson 24

Converters producing a unipolar output voltage. Buck M(D)=D M(D) 2 0.5 0 0 0.5 D 2. Boost M(D)= D M(D) 2 4 3 2 0 0 0.5 D 25

Converters producing a unipolar output voltage 3. Buck-boost M(D)= D D 0 0 0.5 D 2 2 3 4 M(D) 4. Noninverting buck-boost M(D)= D D M(D) 2 4 3 2 2 0 0 0.5 D 26

Converters producing a bipolar output voltage suitable as dc-ac inverters 5. Bridge M(D)=2D M(D) 2 g 2 0 0.5 D 6. Watkins-Johnson 2 or M(D)= 2D D 2 M(D) 0 2 0.5 D 2 3 27

Converters producing a bipolar output voltage suitable as ac-dc rectifiers 7. Current-fed bridge M(D)= 2D M(D) 2 2 2 0 2 0.5 D 8. Inverse of Watkins-Johnson 2 or M(D)= D 2D 2 M(D) 2 0 0.5 D 2 2 28

Several members of the class of two-inductor converters. Cuk M(D)= D D 0 0 0.5 D 2 2 3 4 M(D) 2. SEPIC M(D)= D D M(D) 2 4 3 g 2 0 0 0.5 D 29

Several members of the class of two-inductor converters 3. Inverse of SEPIC M(D)= D D M(D) 4 3 2 2 0 0 0.5 D 4. Buck 2 M(D)=D 2 M(D) 2 2 0.5 0 0 0.5 D 30

6.3. Transformer isolation Objectives: Isolation of input and output ground connections, to meet safety requirements Reduction of transformer size by incorporating high frequency isolation transformer inside converter Minimization of current and voltage stresses when a large step-up or step-down conversion ratio is needed use transformer turns ratio Obtain multiple output voltages via multiple transformer secondary windings and multiple converter secondary circuits 3

A simple transformer model Multiple winding transformer Equivalent circuit model i n : n 2 i 2 i i M i ' n : n 2 i 2 v v 2 v L M v 2 i 3 i 3 : n 3 v 3 v n = v 2 n = v 3 2 n =... 3 0=n i 'n 2 i 2 n 3 i 3... : n 3 v 3 ideal transformer 32

The magnetizing inductance L M Models magnetization of transformer core material Appears effectively in parallel with windings If all secondary windings are disconnected, then primary winding behaves as an inductor, equal to the magnetizing inductance At dc: magnetizing inductance tends to short-circuit. Transformers cannot pass dc voltages Transformer saturates when magnetizing current i M is too large Transformer core B-H characteristic B v dt saturation slope L M H i M 33

olt-second balance in L M The magnetizing inductance is a real inductor, obeying di v =L M M dt integrate: i M i M (0) = L t v (τ) dτ M 0 Magnetizing current is determined by integral of the applied winding voltage. The magnetizing current and the winding currents are independent quantities. olt-second balance applies: in steady-state, i M (T s ) = i M (0), and hence v i i M L M i ' n : n 2 : n 3 ideal transformer i 2 v 2 i 3 v 3 0= T T s v dt s 0 34

Transformer reset Transformer reset is the mechanism by which magnetizing inductance volt-second balance is obtained The need to reset the transformer volt-seconds to zero by the end of each switching period adds considerable complexity to converters To understand operation of transformer-isolated converters: replace transformer by equivalent circuit model containing magnetizing inductance analyze converter as usual, treating magnetizing inductance as any other inductor apply volt-second balance to all converter inductors, including magnetizing inductance 35

6.3.. Full-bridge and half-bridge isolated buck converters Full-bridge isolated buck converter Q D Q 3 D 3 i : n D 5 i D5 L i v T v s C R v Q2 D 2 Q4 D 4 : n D 6 36

Full-bridge, with transformer equivalent circuit Q D Q 3 D 3 i i ' i M : n D 5 i D5 i L v T L M v s C R v Q2 D 2 Q4 D 4 : n ideal D 6 i D6 transformer model 37

Full-bridge: waveforms i M v T i v s i D5 I conducting devices: L M 0 0 n i 0 i L M n 0.5 i 0.5 i 0 0 DT s T s T s DT s 2T s Q D Q 5 2 D 5 Q 4 D Q 6 3 D 6 D 5 D 6 0 38 t During first switching period: transistors Q and Q 4 conduct for time DT s, applying voltseconds DT s to primary winding During next switching period: transistors Q 2 and Q 3 conduct for time DT s, applying voltseconds DT s to primary winding Transformer volt-second balance is obtained over two switching periods Effect of nonidealities?

Effect of nonidealities on transformer volt-second balance olt-seconds applied to primary winding during first switching period: ( (Q and Q 4 forward voltage drops))( Q and Q 4 conduction time) olt-seconds applied to primary winding during next switching period: ( (Q 2 and Q 3 forward voltage drops))( Q 2 and Q 3 conduction time) These volt-seconds never add to exactly zero. Net volt-seconds are applied to primary winding Magnetizing current slowly increases in magnitude Saturation can be prevented by placing a capacitor in series with primary, or by use of current programmed mode (chapter ) 39

Operation of secondary-side diodes v s i D5 conducting devices: n i D 5 D 6 i D5 i D6 0 i v s L C n 0.5 i 0.5 i 0 t 0 DT s T s T s DT s 2T s Q D Q 5 2 D 5 Q 4 D Q 6 3 D 6 D 5 D 6 R 0 v During second (D ) subinterval, both secondary-side diodes conduct Output filter inductor current divides approximately equally between diodes Secondary amp-turns add to approximately zero Essentially no net magnetization of transformer core by secondary winding currents 40

olt-second balance on output filter inductor i D 5 i D5 i L v s I i v s C R v n 0 n 0 D 6 i D6 i D5 i 0.5 i 0.5 i 0 t 0 DT s T s T s DT s 2T s = v s = nd conducting devices: Q D Q 5 2 D 5 Q 4 D Q 6 3 D 6 D 5 D 6 M(D) = nd buck converter with turns ratio 4

Half-bridge isolated buck converter Q D C a i : n D 3 i D3 L i v T v s C R v Q2 D 2 C b : n D 4 Replace transistors Q 3 and Q 4 with large capacitors oltage at capacitor centerpoint is 0.5 v s is reduced by a factor of two M = 0.5 nd 42

6.3.2. Forward converter n : n 2 : n 3 D 2 L D 3 C R Q D Buck-derived transformer-isolated converter Single-transistor and two-transistor versions Maximum duty cycle is limited Transformer is reset while transistor is off 43

Forward converter with transformer equivalent circuit n : n 2 : n 3 D 2 L i M i ' L M v v 2 v 3 D 3 v D3 C R Q i i 2 i 3 D v Q 44

Forward converter: waveforms v i M n n 2 0 Magnetizing current, in conjunction with diode D, operates in discontinuous conduction mode L M n n 2 L M 0 Output filter inductor, in conjunction with diode D 3, may operate in either CCM or DCM v D3 n 3 n 0 0 DT s D 2 T s D 3 T s T s t conducting devices: Q D D 3 D 2 D 3 45

Subinterval : transistor conducts i M n : n 2 : n 3 i ' D 2 on L L M v v 2 v 3 v D3 C R i i 2 i 3 Q on D off 46

Subinterval 2: transformer reset n : n 2 : n 3 L i M i ' L M v v 2 v 3 D 3 on v D3 C R Q off i i 2 = i M n /n2 i 3 D on 47

Subinterval 3 n : n 2 : n 3 L i M = 0 L M v i ' v 2 v 3 D 3 on v D3 C R i i 2 i 3 Q off D off 48

Magnetizing inductance volt-second balance v 0 n n 2 i M L M n n 2 L M 0 DT s D 2 T s D 3 T s T s t conducting devices: Q D 2 D D 3 D 3 v = D ( )D 2 ( n /n 2 )D 3 (0)=0 49

Transformer reset From magnetizing current volt-second balance: Solve for D 2 : v = D ( )D 2 ( n /n 2 )D 3 (0)=0 D 2 = n 2 n D D 3 cannot be negative. But D 3 = D D 2. Hence Solve for D D 3 =DD 2 0 D 3 =D n 2 n 0 D n 2 for n D = n 2 : 2 n 50

What happens when D > 0.5 magnetizing current waveforms, i M D < 0.5 for n = n 2 i M DT s D 2 T s D 3 T s t D > 0.5 DT s D 2 T s t 2T s 5

Conversion ratio M(D) L D 2 D 3 v D3 C R v D3 n 3 n v D3 = = n 3 n D 0 0 DT s D 2 T s D 3 T s T s t conducting devices: Q D 2 D D 3 D 3 52

Maximum duty cycle vs. transistor voltage stress Maximum duty cycle limited to D n 2 n which can be increased by increasing the turns ratio n 2 / n. But this increases the peak transistor voltage: max v Q = n n 2 For n = n 2 D 2 and max v Q =2 53

The two-transistor forward converter D Q D 3 L : n D 4 C R D 2 Q 2 = nd D 2 max v Q = max v Q2 = 54

6.3.3. Push-pull isolated buck converter Q v T : n i D D i L v s C R v T D 2 Q 2 = nd 0 D 55

Waveforms: push-pull i M v T i v s i D I conducting devices: L M 0 0 n i 0 i L M n 0.5 i 0.5 i 0 0 DT s T s T s DT s 2T s Q D Q 2 D D D 2 D 2 D 2 0 t Used with low-voltage inputs Secondary-side circuit identical to full bridge As in full bridge, transformer volt-second balance is obtained over two switching periods Effect of nonidealities on transformer volt-second balance? Current programmed control can be used to mitigate transformer saturation problems. Duty cycle control not recommended. 56

6.3.4. Flyback converter buck-boost converter: Q D L construct inductor winding using two parallel wires: L Q D : 57

Derivation of flyback converter, cont. Isolate inductor windings: the flyback converter Q D : L M Flyback converter having a :n turns ratio and positive output: L M :n D C Q 58

The flyback transformer i g L M transformer model i :n v L D C i C R v A two-winding inductor Symbol is same as transformer, but function differs significantly from ideal transformer Energy is stored in magnetizing inductance Q Magnetizing inductance is relatively small Current does not simultaneously flow in primary and secondary windings Instantaneous winding voltages follow turns ratio Instantaneous (and rms) winding currents do not follow turns ratio Model as (small) magnetizing inductance in parallel with ideal transformer 59

Subinterval transformer model i g i :n i C L M v L C R v v L = i C = R v i g =i CCM: small ripple approximation leads to v L = i C = R i g =I 60

Subinterval 2 i g =0 transformer model i v L v/n :n i/n C i C R v v L = v n i C = i n v R i g =0 CCM: small ripple approximation leads to v L = n i C = I n R i g =0 6

CCM Flyback waveforms and solution v L olt-second balance: v L = D ( )D'( n )=0 /n Conversion ratio is i C I/n /R M(D)= =n D D' Charge balance: i g /R I 0 i C = D ( R )D'(I n R )=0 Dc component of magnetizing current is I = n D'R Dc component of source current is conducting devices: DT s T s D'T s Q D t I g = i g = D (I)D'(0) 62

Equivalent circuit model: CCM Flyback v L = D ( )D'( n )=0 i C =D( R )D'(I n R )=0 I g DI D' D'I n R D n I I g = i g =D(I)D'(0) : D D' : n I g I R 63

Discussion: Flyback converter Widely used in low power and/or high voltage applications Low parts count Multiple outputs are easily obtained, with minimum additional parts Cross regulation is inferior to buck-derived isolated converters Often operated in discontinuous conduction mode DCM analysis: DCM buck-boost with turns ratio 64

6.3.5. Boost-derived isolated converters A wide variety of boost-derived isolated dc-dc converters can be derived, by inversion of source and load of buck-derived isolated converters: full-bridge and half-bridge isolated boost converters inverse of forward converter: the reverse converter push-pull boost-derived converter Of these, the full-bridge and push-pull boost-derived isolated converters are the most popular, and are briefly discussed here. 65

Full-bridge transformer-isolated boost-derived converter i L v T Q Q 3 : n D i o v T C R v : n Q 2 Q 4 D 2 Circuit topologies are equivalent to those of nonisolated boost converter With : turns ratio, inductor current i and output current i o waveforms are identical to nonisolated boost converter 66

Transformer reset mechanism v T i o conducting devices: 0 0 0 DT s Q Q 2 Q 3 Q 4 /n I/n 0 /n I/n D'T s DT s D'T s T s Q Q Q 2 T s Q 2 Q 4 Q 3 D Q 3 Q 4 D 2 t As in full-bridge buck topology, transformer voltsecond balance is obtained over two switching periods. During first switching period: transistors Q and Q 4 conduct for time DT s, applying volt-seconds DT s to secondary winding. During next switching period: transistors Q 2 and Q 3 conduct for time DT s, applying volt-seconds DT s to secondary winding. 67

Conversion ratio M(D) v L /n /n Application of volt-second balance to inductor voltage waveform: v L = D ( )D'( /n)=0 i I Solve for M(D): M(D)= = n D' conducting devices: Q Q 2 Q 3 Q 4 Q D DT s Q Q 2 Q 3 Q 4 T s D'T s Q 4 Q 2 Q 3 D 2 t boost with turns ratio n 68

Push-pull boost-derived converter i o v L T i C R v L v T Q : n D Q 2 D 2 M(D)= = n D' 69

Push-pull converter based on Watkins-Johnson converter Q : n D C R Q 2 D 2 70

6.3.6. Isolated versions of the SEPIC and Cuk converter Basic nonisolated SEPIC L C D L 2 C 2 R v Q L C D Isolated SEPIC i i p i s C 2 R v Q : n 7

Isolated SEPIC i p i L C i p i i 2 : n is D Q L M = L 2 C 2 R v i s i 2 (i i 2 ) / n ideal transformer model 0 i I M(D)= = nd D' i 2 I 2 conducting devices: DT s T s D'T s Q D t 72

Inverse SEPIC Nonisolated inverse SEPIC Q C L 2 L D C 2 R v Isolated inverse SEPIC : n C D L 2 C 2 R v Q 73

Obtaining isolation in the Cuk converter L L 2 Nonisolated Cuk converter C Q D C 2 R v L C a C b L2 Split capacitor C into series capacitors C a and C b Q D C 2 R v 74

Isolated Cuk converter Insert transformer between capacitors C a and C b C L a C b Q D L2 C 2 R v M(D)= = nd D' : n Discussion Capacitors C a and C b ensure that no dc voltage is applied to transformer primary or secondary windings Transformer functions in conventional manner, with small magnetizing current and negligible energy storage within the magnetizing inductance 75

6.4. Converter evaluation and design For a given application, which converter topology is best? There is no ultimate converter, perfectly suited for all possible applications Trade studies Rough designs of several converter topologies to meet the given specifications An unbiased quantitative comparison of worst-case transistor currents and voltages, transformer size, etc. Comparison via switch stress, switch utilization, and semiconductor cost Spreadsheet design 76

6.4.. Switch stress and switch utilization Largest single cost in a converter is usually the cost of the active semiconductor devices Conduction and switching losses associated with the active semiconductor devices often dominate the other sources of loss This suggests evaluating candidate converter approaches by comparing the voltage and current stresses imposed on the active semiconductor devices. Minimization of total switch stresses leads to reduced loss, and to minimization of the total silicon area required to realize the power devices of the converter. 77

Total active switch stress S In a converter having k active semiconductor devices, the total active switch stress S is defined as where S = k Σ j = j I j j is the peak voltage applied to switch j, I j is the rms current applied to switch j (peak current is also sometimes used). In a good design, the total active switch stress is minimized. 78

Active switch utilization U It is desired to minimize the total active switch stress, while maximizing the output power P load. The active switch utilization U is defined as U = P load S The active switch utilization is the converter output power obtained per unit of active switch stress. It is a converter figure-of-merit, which measures how well a converter utilizes its semiconductor devices. Active switch utilization is less than in transformer-isolated converters, and is a quantity to be maximized. Converters having low switch utilizations require extra active silicon area, and operate with relatively low efficiency. Active switch utilization is a function of converter operating point. 79

CCM flyback example: Determination of S During subinterval 2, the transistor blocks voltage Q,pk equal to plus the reflected load voltage: L M :n D C Q,pk = / n = D' Q Transistor current coincides with i g. RMS value is I Q,rms = I D = P load D i g I Switch stress S is S = Q,pk I Q,rms =( /n)(i D) DT s 0 D'T s t conducting devices: T s Q D 80

CCM flyback example: Determination of U Express load power P load in terms of and I: P load = D' I n Previously-derived expression for S: S = Q,pk I Q,rms =( /n)(i D) : D D' : n I g I R CCM flyback model Hence switch utilization U is U = P load S = D' D 8

Flyback example: switch utilization U(D) For given,, P load, the designer can arbitrarily choose D. The turns ratio n must then be chosen according to 0.4 0.3 max U = 0.385 at D = /3 n = D' D U 0.2 Single operating point design: choose D = /3. small D leads to large transistor current 0. large D leads to large transistor voltage 0 0 0.2 0.4 0.6 0.8 D 82

Comparison of switch utilizations of some common converters Table 6.. Active switch utilizations of some common dc-dc converters, single operating point. Converter U(D) max U(D) max U(D) occurs at D = Buck Boost Buck-boost, flyback, nonisolated SEPIC, isolated SEPIC, nonisolated Cuk, isolated Cuk Forward, n = n 2 Other isolated buck-derived converters (fullbridge, half-bridge, push-pull) Isolated boost-derived converters (full bridge, push-pull) D D' D D' D 2 D D 2 2 D' 2 D 0 2 3 3 = 0.385 3 2 2 = 0.353 2 2 2 = 0.353 2 0 83

Switch utilization : Discussion Increasing the range of operating points leads to reduced switch utilization Buck converter can operate with high switch utilization (U approaching ) when D is close to Boost converter can operate with high switch utilization (U approaching ) when D is close to Transformer isolation leads to reduced switch utilization Buck-derived transformer-isolated converters U 0.353 should be designed to operate with D as large as other considerations allow transformer turns ratio can be chosen to optimize design 84

Switch utilization: Discussion Nonisolated and isolated versions of buck-boost, SEPIC, and Cuk converters U 0.385 Single-operating-point optimum occurs at D = /3 Nonisolated converters have lower switch utilizations than buck or boost Isolation can be obtained without penalizing switch utilization 85

Active semiconductor cost vs. switch utilization semiconductor cost per kw output power = semiconductor device cost per rated ka voltage derating factor current derating factor converter switch utilization (semiconductor device cost per rated ka) = cost of device, divided by product of rated blocking voltage and rms current, in $/ka. Typical values are less than $/ka (voltage derating factor) and (current derating factor) are required to obtain reliable operation. Typical derating factors are 0.5-0.75 Typical cost of active semiconductor devices in an isolated dc-dc converter: $ - $0 per kw of output power. 86

6.4.2. Converter design using computer spreadsheet Given ranges of and P load, as well as desired value of and other quantities such as switching frequency, ripple, etc., there are two basic engineering design tasks: Compare converter topologies and select the best for the given specifications Optimize the design of a given converter A computer spreadsheet is a very useful tool for this job. The results of the steady-state converter analyses of chapters -6 can be entered, and detailed design investigations can be quickly performed: Evaluation of worst-case stresses over a range of operating points Evaluation of design tradeoffs 87

Spreadsheet design example Specifications maximum input voltage 390 minimum input voltage 260 output voltage 5 maximum load power P load 200W minimum load power P load 20W switching frequency f s 00kHz maximum output ripple v 0. Input voltage: rectified 230rms ±20% Regulated output of 5 Rated load power 200W Must operate at 0% load Select switching frequency of 00kHz Output voltage ripple 0. Compare single-transistor forward and flyback converters in this application Specifications are entered at top of spreadsheet 88

Forward converter design, CCM n : n 2 : n 3 D 2 L D 3 C R Q D Design variables reset winding turns ratio n 2 / n turns ratio n 3 / n 0.25 inductor current ripple i 2A ref to sec Design for CCM at full load; may operate in DCM at light load 89

Flyback converter design, CCM :n D L M C Q Design variables turns ratio n 2 / n 0.25 inductor current ripple i 3A ref to sec Design for CCM at full load; may operate in DCM at light load 90

Enter results of converter analysis into spreadsheet (Forward converter example) Maximum duty cycle occurs at minimum and maximum P load. Converter then operates in CCM, with D = n n 3 g Inductor current ripple is Solve for L: i = D' T s 2L L = D' T s 2 i i is a design variable. For a given i, the equation above can be used to determine L. To ensure CCM operation at full load, i should be less than the full-load output current. C can be found in a similar manner. 9

Forward converter example, continued Check for DCM at light load. The solution of the buck converter operating in DCM is = n 3 2 g n 4K/D 2 with K =2L/RT s, and R = 2 / P load These equations apply equally well to the forward converter, provided that all quantities are referred to the transformer secondary side. Solve for D: D = 2 K 2 2n 3 n in DCM D= n n 3 g in CCM at a given operating point, the actual duty cycle is the small of the values calculated by the CCM and DCM equations above. Minimum D occurs at minimum P load and maximum. 92

More regarding forward converter example Worst-case component stresses can now be evaluated. Peak transistor voltage is max v Q = n n 2 Rms transistor current is I Q, rms = n 3 n D I 2 ( i) 2 /3 n 3 n DI (this neglects transformer magnetizing current) Other component stresses can be found in a similar manner. Magnetics design is left for a later chapter. 93

Results: forward and flyback converter spreadsheets Forward converter design, CCM Flyback converter design, CCM Design variables Design variables reset winding turns ratio n 2 / n turns ratio n 2 / n 0.25 turns ratio n 3 / n 0.25 inductor current ripple i 3A ref to sec inductor current ripple i 2A ref to sec Results Results maximum duty cycle D 0.462 maximum duty cycle D 0.36 minimum D, at full load 0.308 minimum D, at full load 0.235 minimum D, at minimum load 0.25 minimum D, at minimum load 0.79 Worst-case stresses Worst-case stresses peak transistor voltage v Q 780 peak transistor voltage v Q 50 rms transistor current i Q.3A rms transistor current i Q.38A transistor utilization U 0.226 transistor utilization U 0.284 peak diode voltage v D 49 peak diode voltage v D 64 rms diode current i D 9.A rms diode current i D 6.3A peak diode voltage v D2 49 peak diode current i D 22.2A rms diode current i D2.A rms output capacitor current i C.5A rms output capacitor current i C 9.A 94

Discussion: transistor voltage Flyback converter Ideal peak transistor voltage: 50 Actual peak voltage will be higher, due to ringing causes by transformer leakage inductance An 800 or 000 MOSFET would have an adequate design margin Forward converter Ideal peak transistor voltage: 780, 53% greater than flyback MOSFETs having voltage rating greater than 000 are not available (in 995) when ringing due to transformer leakage inductance is accounted for, this design will have an inadequate design margin Fix: use two-transistor forward converter, or change reset winding turns ratio A conclusion: reset mechanism of flyback is superior to forward 95

Discussion: rms transistor current Forward Flyback.3A worst-case transistor utilization 0.226.38A worst case, 22% higher than forward transistor utilization 0.284 CCM flyback exhibits higher peak and rms currents. Currents in DCM flyback are even higher 96

Discussion: secondary-side diode and capacitor stresses Forward Flyback peak diode voltage 49 rms diode current 9.A /.A rms capacitor current.5a peak diode voltage 64 rms diode current 6.3A peak diode current 22.2A rms capacitor current 9.A Secondary-side currents, especially capacitor currents, limit the practical application of the flyback converter to situations where the load current is not too great. 97

Summary of key points. The boost converter can be viewed as an inverse buck converter, while the buck-boost and Cuk converters arise from cascade connections of buck and boost converters. The properties of these converters are consistent with their origins. Ac outputs can be obtained by differential connection of the load. An infinite number of converters are possible, and several are listed in this chapter. 2. For understanding the operation of most converters containing transformers, the transformer can be modeled as a magnetizing inductance in parallel with an ideal transformer. The magnetizing inductance must obey all of the usual rules for inductors, including the principle of volt-second balance. 98

Summary of key points 3. The steady-state behavior of transformer-isolated converters may be understood by first replacing the transformer with the magnetizing-inductance-plus-ideal-transformer equivalent circuit. The techniques developed in the previous chapters can then be applied, including use of inductor volt-second balance and capacitor charge balance to find dc currents and voltages, use of equivalent circuits to model losses and efficiency, and analysis of the discontinuous conduction mode. 4. In the full-bridge, half-bridge, and push-pull isolated versions of the buck and/or boost converters, the transformer frequency is twice the output ripple frequency. The transformer is reset while it transfers energy: the applied voltage polarity alternates on successive switching periods. 99

Summary of key points 5. In the conventional forward converter, the transformer is reset while the transistor is off. The transformer magnetizing inductance operates in the discontinuous conduction mode, and the maximum duty cycle is limited. 6. The flyback converter is based on the buck-boost converter. The flyback transformer is actually a two-winding inductor, which stores and transfers energy. 7. The transformer turns ratio is an extra degree-of-freedom which the designer can choose to optimize the converter design. Use of a computer spreadsheet is an effective way to determine how the choice of turns ratio affects the component voltage and current stresses. 8. Total active switch stress, and active switch utilization, are two simplified figures-of-merit which can be used to compare the various converter circuits. 00