Eye Tracking Instructions



Similar documents
Tobii TX 300. Experiment Room. Participant

Protocol for Microscope Calibration

Intro to 3D Animation Using Blender

MAINTENANCE & TROUBLESHOOTING

3D-GIS in the Cloud USER MANUAL. August, 2014

SMART board 101. SMART board 101 Training

Create a Poster Using Publisher

CATIA Basic Concepts TABLE OF CONTENTS

Lab 3 - DC Circuits and Ohm s Law

Tutorial for Tracker and Supporting Software By David Chandler

HOW TO VIEW AND EDIT PICTURES

Care and Use of the Compound Microscope

Introduction to Google SketchUp (Mac Version)

PowerWorld Simulator

Chapter 1. Creating Sketches in. the Sketch Mode-I. Evaluation chapter. Logon to for more details. Learning Objectives

Instructions for Formatting APA Style Papers in Microsoft Word 2010

User Guide LUXXOR VIDEO MICROSCOPE. 2 Luxxor Video Microscope Set Up

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On

Photoshop- Image Editing

SMART Boards. If the board is connected to a different computer - Orientation is needed whenever you connect it to a new or different computer.

The Lighting Effects Filter

Handout: Word 2010 Tips and Shortcuts

Communicate: In Print

Introduction to SketchUp

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

Kinect Interface to Play Computer Games with Movement

Maximizing Microsoft Office Communicator

Organizing image files in Lightroom part 2

If you know exactly how you want your business forms to look and don t mind

-ipad 2: Quick Reference Guide-

1. Three-Color Light. Introduction to Three-Color Light. Chapter 1. Adding Color Pigments. Difference Between Pigments and Light. Adding Color Light

MestRe-C User Guide Megan Bragg 04/14/05

MAINTENANCE & TROUBLESHOOTING

LEGO Digital Designer 4.3 User Manual

Scan2CRM for ACT! User Guide

Instructions for Formatting MLA Style Papers in Microsoft Word 2010

Adobe Illustrator CS5 Part 1: Introduction to Illustrator

COLLEGE OF MEDICINE. Sony Portable Video Conference Systems. Operations Manual

LESSON 7: IMPORTING AND VECTORIZING A BITMAP IMAGE

Getting Started on the Computer With Mouseaerobics! Windows XP

Micro Cam Software. User Manual V1.3

E-Loader Operation Manual

Operating Manual for UVEX-p (JAN Scientific, Inc. Aug 2014)

SolarTrak Users Guide GPS Satellites

3D Viewer. user's manual _2

Epson Brightlink Interactive Board and Pen Training. Step One: Install the Brightlink Easy Interactive Driver

Recipes4Success. Animate a Rocket Ship. Frames 6 - Drawing Tools

Word 2007 WOWS of Word Office 2007 brings a whole new basket of bells and whistles for our enjoyment. The whistles turn to wows.

Eye Tracking System Instruction. Manual. Model Mobile Head Mounted Optics with Mobile Electronics Package (Addendum to Model 501 manual)

HP Display Assistant User Guide

SpaceClaim Introduction Training Session. A SpaceClaim Support Document

understanding sensors

Instructions for Creating a Poster for Arts and Humanities Research Day Using PowerPoint

Laser Cutter User Manual

What Do You Think? for Instructors

3DVista Virtual Tour Suite

Windows XP Pro: Basics 1

5. Tutorial. Starting FlashCut CNC

The Applied Imaging Cytogenetic Workstation

1. Installing The Monitoring Software

DVB-T PenType USB Receiver. User s Manual

Tutorials. If you have any questions, comments, or suggestions about these lessons, don't hesitate to contact us at

AODA Mouse Pointer Visibility

Quick Start Guide Simple steps for editing and manipulating your photo.

Creating a Logo in CorelDRAW

Microsoft PowerPoint 2010 Handout

Video Baby Monitor System. User Guide

Chapter 23: Drafting in Worksheet View

Pro Flight Rudder Pedals

Create A Collage Of Warped Photos

GETTING STARTED TABLE OF CONTENTS

CONSTRUCTING SINGLE-SUBJECT REVERSAL DESIGN GRAPHS USING MICROSOFT WORD : A COMPREHENSIVE TUTORIAL

Using Microsoft Word. Working With Objects

Open icon. The Select Layer To Add dialog opens. Click here to display

HOW TO GET A SOIL MAP FROM THE WEB SOIL SURVEY

Adobe InDesign Creative Cloud

EEG Cap Instructions

NVMS User Manual

Microsoft Picture Manager. Picture Manager

Software Application Tutorial

X-Trade Brokers Dom Maklerski S.A. XTB Expert Builder. Tutorial. Michał Zabielski

Avigilon Control Center Web Client User Guide

Internet Explorer 7. Getting Started The Internet Explorer Window. Tabs NEW! Working with the Tab Row. Microsoft QUICK Source

DIVA User Guide. DIVA User Guide. Version 2.0.1

Lead Management System

D2L: An introduction to CONTENT University of Wisconsin-Parkside

CREATING A 3D VISUALISATION OF YOUR PLANS IN PLANSXPRESS AND CORTONA VRML CLIENT

TouchKit Software User manual for Windows 7 Version:

EPSON SCANNING TIPS AND TROUBLESHOOTING GUIDE Epson Perfection 3170 Scanner

Welcome to CorelDRAW, a comprehensive vector-based drawing and graphic-design program for the graphics professional.

Blender 2.49b How to generate 3D-images?

USER S MANUAL. AXIS Mobile Monitor

How to use the Microfilm Reader/Scanner

Creating Drawings in Pro/ENGINEER

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

Publisher 2010 Cheat Sheet

Microsoft PowerPoint Tutorial

idisplay v.2.0 User Guide

Transcription:

Eye Tracking Instructions [1] Check to make sure that the eye tracker is properly connected and plugged in. Plug in the eye tracker power adaptor (the green light should be on. Make sure that the yellow cable is connected to the gold RCA plug, and the black cable is connected to the black power adaptor plug. The red cable should never be detached! Remove the lens cap from the camera (if applicable). [2] Know the parts of the eye tracker. forehead rest/nose piece helps to keep subjects still chin rest help to keep subjects still light bulb infra-red illumination camera infrared filter; only sensitive to IR light y adjust loosen these knob to move up/down z adjust loosen these to move towards/away from Ss x adjust loosen these knobs to move camera left/right Always make sure y adjust knobs are well tightened!!!

[3] Start the eye tracker / set up subject Start the viewpoint eye tracker control program by clicking on the shortcut to viewpoint.exe. You will see a welcome screen that looks like this: Click on the white splash screen to start using the eye tracker. Make sure that the eye tracker is clean. (Alcohol and cotton squares are on the back table). Loosen all three y-adjust knobs. Have your subject sit (ideally) on one of the lab stools. This will prevent the subject from swinging back and forth. They should lean forward so that they are comfortable (not slouching) and you should move the forehead rest for them. Make sure that the forehead rest is tightened.

Next, adjust the chin rest (using both y and z adjust) to the subject s chin. You will need to move the camera out of the way for this. Lastly, move the camera (using y and z, and x only if necessary) so that you can see the eye on the viewpoint eye tracker window. If your experiment requires headphones, make sure they are positioned and sound-checked before you position the eye camera! [4] Tracking the eye / how eye tracking works The black circle (outlined in yellow here, meaning that the computer is tracking the pupil) is the pupil where light enters the eye. The light doesn t reflect back out, so the pupil shows up as black. It is surrounded by the iris, which is colored under visible light, but grey under IR light. The white spot just below the pupil is a reflection (of the IR light bulb) off of the cornea, and is called the glint. The subwindow that shows the image of the eye is called the EyeCamera subwindow.

The eye tracker works most accurately by comparing the relationship of the location of the glint to the location of the pupil. Activate this function of the eye tracker by switching to the EyeA dialog in the Controls subwindow. [Next, select Glint-Pupil Vector from the Feature Method drop-down box at the top of the dialog. Have the subject look at the white circle on the upper edge of the monitor during this initial testing, or at the image of their own eye.]** ** As of 2/2010, this is pre-set in the start-up settings. You will notice that the glint is now surrounded by a red circle (this means that the computer has found the glint), and that a blue line has been drawn out from the center of the pupil. You may have trouble getting the computer to find the glint. Here are two trouble shooting techniques: [A] Adjust the camera Be very careful when performing any of these operations. The camera can be adjusted in five different ways. 1. use the z adjust to move the camera closer or farther away from the eye (the glint should not be too large or doubled) 2. use the x adjust the move the camera left or right 3. change the tilt of the camera (about 30º above the horizontal is good) 4. change rotation of the camera (so that the eye is horizontal) 5. change the focus of the camera (the eye should be just out of focus) When the subject looks to the upper left of the monitor (the initial test position), the pupil should be in the upper right quadrant of the larger box on the screen. Illumination should be good over the entire camera view. There should only be one glint visible and the pupil should not be occluded by eyelashes. Note that glasses and screen printed contacts will cause the eye tracker to fail to track in most cases.

[B] Adjust the threshold and search region settings. If the eye is positioned correctly, but the computer is still not tracking correctly, there may be a problem with the threshold or with the region that the eye tracker is searching. Problems with the pupil threshold lead to the green dot mesh extending to areas beyond the pupil, and may result in the yellow pupil tracking circle moving or becoming very large. These occur because the computer is looking for dark areas (i.e. the pupil). You should set the threshold as low as possible while still being able to consistently track the pupil. Solution: Use the Pupil slider in the Control subwindow to select the grey values that will be considered as pupil. This value will likely be 0.12 or below, but could be as high as 0.20 with a good image. Positive-Lock Threshold Tracking should be off (unchecked). Problems with the glint threshold lead to the glint hopping from one location to another and to an expansion of the purple dot mesh. The computer is searching for bright (white) areas in this case; the threshold should be set as high as possible. Solution: Use the Glint slider in the Control subwindow to select the grey values that will be considered as glint. This value will likely be 0.80 or above; in the majority of cases, this value will be 1.00. Note that the green and purple meshes never extend beyond the two boxes on the screen. These boxes determine the area of the camera view that will be searched for the pupil and glint, and can be used to avoid dark/mascara covered eyelashes (pupil) and extraneous reflections off of the skin or eye ball (glint). The black dot in a box and the white dot in a box buttons on the right side of eh EyeCamera subwindow allow you to redraw these boxes. The button and the corresponding box will turn red when selected.

Always draw boxes from upper left to lower right! Click on the lock button on the right side of the EyeCamera subwindow when you are done adjusting the boxes. Note that the pupil must be within the pupil boxes no matter where the subject looks on the screen in order for the tracker to work (and likewise for the glint and the glint box). Have the subject look at all four corners of the screen to make sure that any boxes you redraw are acceptable. Use the letters and central eye on the stimulus display or your mouse cursor to accomplish this. You may also want to show the subject their own eye. Note that the eye tracking computers use a two monitor setup. The monitor that the subject will be viewing stimuli on is monitor 2. Click, hold, and drag the title bar of the Viewpoint EyeTracker window over to monitor 2. You will need to press F2 first to turn off the stimulus display before moving the window. When you have the subject look around the stimulus display (at the letters), read the letters in random order, or the subjects will try to guess and won t hold their eye steady. The yellow pupil circle and the red glint circle should be stable no matter where on the screen the subject looks. If it is unstable in one of the far corners, calibrate will extra points (25 or 36) and omit the points that don t work. If the circles are stable, is time to teach the computer how the eye is moving relative to the screen. If not, use the trouble shooting steps above. [Lastly, set up monitor 2 for the subject. Under the Stimuli menu, select View Source and then Viewpoint Stimulus Window (not Interactive Computer Display). Pressing F2 will toggle whether or not the subject s (stimulus) screen is visible. Press F2 and more the Viewpoint EyeTracker window back to monitor 1.] ** As of 2/2010, this is pre-set in the start-up settings. (optional) If you are running a High Precision study, press the Mode button on the EyeCamera window and switch the Mode to High Precision.

[5] Calibrate the eye tracker Calibration is the process of teaching the computer how the eye moves relative to where a person is looking on the screen. For a good calibration: 1. The pupil and glint must be tracked successfully in all regions of the screen. 2. The computer must record images of the eye while the subject looks at known points on the screen. 3. The eye must be stationary when those images are recorded. Below the EyeCamera subwindow is the EyeSpace subwindow. It records how the computer is translating images of the eye into locations on the screen. It starts out as a very large, regular grid. You should have a much smaller, but still regular grid when you are done calibration. Read the following to your subject to prepare them for calibration: We are now going to give the computer information about how your eye is positioned when you look at different points on the screen. This is called calibration. In a moment, the screen in front of you will turn grey. You will see a Get Ready warning sign, and then a green box will appear on the screen. Look at the center of the box. The box will get smaller and smaller until it disappears into a white dot, then it will get larger again. Keep looking at white dot in the center of the box while this happens! This process will re-occur a total of sixteen times. Don t try to guess where the box will appear next it s totally random. I ll monitor the computer s progress, and we may redo some points if necessary. Once we are done with this procedure, you need to remain as still as possible. Try not to talk or move your head. Give me a thumb s up sign if you are ready. When the subject is ready, click the Auto-Calibrate button in the EyeSpace subwindow. The calibration sequence will begin.

Often the subject will not hold their eyes stationary during one or more calibration points, so the expected evenly-space grid does not form. This is readily evident in the EyeSpace window because one or more points will be out of place on the grid.. The cursor that the subject is moving with their eyes (on monitor 2) will also track poorly (relative to what they are looking at). You can click directly on the out of place points to select them for recalibrating. Press the Re-present button to present the trouble points a second (or third, or fourth) time. If the point will not move into the grid, watch the EyeCamera subwindow you may be losing either the pupil or the glint at that point. If it is impossible to track that particular corner (it usually is one of the corner points), press the omit button to leave that point out of the calibration. This will lead to poor tracking in that corner, but we using display stimuli with a safety border around them anyway. Use the Re-center button and the Zoom slider to get a better look at your grid. This grid is pretty wicked good. The box represents the location of the subject s eye. Move your mouse cursor around monitor 2 and have the subject follow it to check calibration.

[6] Run the start-up test file (currently MAPS). This will help you get used to monitoring monitor the eye in the EyeCamera subwindow, and the subject s eye movements in the GazeSpace subwindow (these will show up as green lines and spots). The subject will also get used to seeing displays change most tracking failures occur early on, so this will give you a change to correct things. Press CTRL-L to open up the settings file dialog. Navigate to the MAPS folder and choose the first settings file lista.txt. Give the subject the following instructions: You will now see a series of maps on the computer screen. Simply look at the maps while I monitor the computer equipment to make sure that it is running correctly. This is a test of the equipment, not part of the experiment. A series of images will be displayed on the monitor. Simply monitor the subject s eye and eye movements to ensure that nothing seems odd. A data file will be opened automatically by the program. The name of that file will be listed next to File on the Status Window. Write down the name of the data file. When you see an exclamation mark after the series of pictures has been completed, you may start your experiment. [7] Now start the your experiment. Press CTRL-L to open up the settings file dialog. Navigate to the correct folder and choose the appropriate settings file. Always remember to write down the data file name. The program should close your data file automatically when done. Press CTRL-W to close the data file if it does not.