FIRE SPRINKLER DEMONSTRATION TRAILER



Similar documents
WHAT YOU NEED TO KNOW ABOUT INSURING A HOME WITH FIRE SPRINKLERS

FIVE YEAR CERTIFICATION REPORT

Home Fire Sprinkler Facts vs. Myths

Name Of Occupancy Date. Yes No Describe

How To Set Up An Rv Camper Trailer

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

EFSN Training i Module Minutes

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Class 5 to 7 Truck and Bus Hydraulic Brake System

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Inspection and Testing of Water-Based Systems

CANTON FIRE DEPARTMENT

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Your safety and the safety of others are very important.

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Make sure oven is OFF. Never remove parts or touch the fan unless the oven is OFF.

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Please keep this manual for f uture reference.

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Troubleshooting Guide for Jacks Down LED Lights

Installation Instructions for Alarm Module Kit A043F059

CARING FOR YOUR WATER HEATER

Walbro 255lph Inline Fuel Pump Install Procedure

Town of Bellingham Fire Department

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Maintaining Fire Protection Systems

15GAL STEEL OIL DRAIN WITH 110V PUMP

Cooling system components, removing and installing

18SP653* EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation

Roland Garcia Pearland Fire Department

Cooling system components, removing and installing

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Fighting Fire in Sprinklered Buildings. Student Guide

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:


HYLA NST Cleaning System

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

XL PREMIUM OIL COOLER KIT

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions and Service Manual

Fire Pump Plan Review March 2010

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Installation Instructions and Service Manual

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Power Window/Power Lock Installation. To begin with you will need all the parts listed below:

MARKETING HOMES PROTECTED BY FIRE SPRINKLER SYSTEMS

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Geyser-R Heat pump water heater Installation manual

Risk Engineering Guideline

COOLING SYSTEM Section Page

Pressure Vessels (Air Compressors) and LPG Tanks

Automatic Fire Sprinkler Submittal Requirements

National- Spencer Inc.

Commercial Fire Inspections

Emergency Response Guide

Utility Distribution Systems

Emergency Response. Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc.

Rexroth Hydraulic Pump A10VO Series User Manual

VOYAGER 570G. 744A Sprayer Control

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

Assembly overview - fuel tank

Air Conditioner Water Heater Model ACWH18

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Firefighter Review. Instructor Guide

TENANT AND LANDLORD REPAIR RESPONSIBILITIES

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

A Do-It-Yourself Home Water Audit

TECHNICAL ADVISORY BULLETIN

Turbocharger system components, servicing

Draining and filling cooling system

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

1R / 4-BUTTON SERIES

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Lebanon Fire Department Lebanon Engine 512 Check Sheet

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

1000-LB. TRAILER JACK OWNER S MANUAL

Transcription:

IFIA FIRE SPRINKLER DEMONSTRATION TRAILER Recommendations for utilizing the fire sprinkler demonstration trailer in your fire department, business or association: INDEX: A) Picking up and towing the Trailer. B) Conducting a live burn demonstration. C) Recommendations for the Public Education presentation. The trailer is stored at Fire Sprinkler Fitters Local #281 training hall at 11900 S. Laramie, Alsip, IL (just north of Alsip Fire Department Station #2). Their phone number is 708.597.1800. A) Instructions for towing the IFIA Fire Sprinkler Trailer: FROM THE ILLINOIS VEHICLE CODE: (625 ILCS 5/Ch. 12 Art. III heading) ARTICLE III. BRAKES (625 ILCS 5/12-301) (from Ch. 95 1/2, par. 12-301) Sec. 12-301. Brakes 4. Except as provided in paragraph 4.1, every trailer or semi-trailer of a gross weight of over 3,000 pounds, when operated upon a highway must be equipped with brakes adequate to control the movement of, to stop and to hold such vehicle, and designed so as to be operable by the driver of the towing vehicle from its cab. Such brakes must be so designed and connected that in case of an accidental breakaway of a towed vehicle over 5,000 pounds, the brakes are automatically applied. 4.1 Every boat trailer of a gross weight of over 3,000 pounds, when operated upon a highway, must be equipped with brakes adequate to control the movement of, to stop, and to hold that boat trailer. The brakes must be designed to ensure that, in case of an accidental breakaway of a towed boat trailer over 5,000 pounds, the brakes are automatically applied. 5. Every motor vehicle, trailer, pole trailer or semi-trailer, sold in this state or operated upon the highways shall be equipped with service brakes upon all wheels of every such vehicle, except any motor-driven cycle, and except that any trailer, pole trailer or semi-trailer 3,000 pounds gross weight or less need to be equipped with brakes, and except that any trailer or semi-trailer with gross weight over 3,000 pounds but under 5,001 pounds need be equipped with brakes on only one wheel on each side of the vehicle. Any motor vehicle and truck tractor having 3 or more axles and manufactured prior to July 25, 1980 need not have brakes on the front wheels, except when such vehicles are equipped with at least 2 steerable axles, the wheels of one such axle need not be equipped with brakes. However, a vehicle that is more than 30 years of age and which is driven on the highways only in going to and returning from an antique auto show or for servicing or for a demonstration need be equipped with 2 wheel brakes only.

TOWING The towing vehicle must have a Class III hitch, and a 2 5/16 ball. The safety sway bars must be attached. Hitch must be secure with rod & nuts. Trailer brake light connector has a hexagon shaped adapter and must be connected before towing vehicle (test all lights before moving). Retract trailer jack stand and connect safety chains before towing. Remove the wood blocks under the wheels. (Wood blocks provided for jack stand are to remain with vehicle at all times.) When towing, all access panels and doors should be closed and locked. Steps should be in the retracted position and all four leveling jacks should be brought to the upright position. Electrical 110V adapter must be stored on the inside of trailer through the port hole. * Trailer weight is 7,000 lbs. **Ensure that the water tank is empty! (Open main drain before turning the main trailer hand crank screw, and before towing.) B) Fire Sprinkler Trailer Valve Position Description (Make sure the fire sprinkler valves are in the following positions) PRIMING VALVE: Normally closed. (Black) PUMP TEST VALVE: Normally closed. (Also acts as a drain.) (Yellow) TANK MAIN DRAIN: Normally closed. Use to drain tank and lines when burns are complete PRIOR to transport. (Red) MAIN CONTROL VALVE: Normally open. To remain in open position for all burns. Close valve when changing sprinkler head. (Blue) EMERGENCY DELUGE CONTROL VALVE: Normally closed. Controls deluge head in burn room. Use to test if water is in system and in emergency. (Black) PUMP TEST: Normally closed; unless testing. (Yellow) Instructions for Conducting Fire Sprinkler Burn Demonstrations: REMOVE GENERATOR FROM THE TRAILER. 1. Connect trailer extension cord and adapters to an electrical source (wall outlet, generator, etc.). Remove cord from

wall and route through the hole in front of trailer (left side of tank) to the electrical source. Check main electric panel to verify that there is power to the trailer. Switch on all of the breakers. Operate all wall switches for lights and fans. 2. Check the smoke detector and 9V battery with the test button. 3. At this point, turn all valves on the riser to the closed position. Fill the water tank with a garden hose, direct fill pipe, booster line, or fire hose through the top, twist open cap (approx. 150+ gal.). If relying on the reserve tank, do not conduct burns with less than ¼ tank of water. (The sprinkler head can utilize approximately 15 gallons per minute while operating.) Option: Fire Department Connection If the pump is not operating or you do not wish to use the pump, the FDC (Fire Department Connection) can be utilized. Connect to a hydrant using 1 ½ or 1 ¾ hose or to a pumper using idle pressure only. Flush the hydrant prior to connecting the fire hose to remove sediment and debris. 4. Using a piece of 100% cotton material (or unbleached muslin) size for use as a simulated curtain. Hang fabric over the bar so that it rests partially into the supplied metal garbage can. Then secure with clips. 5. Overfill the garbage can with newspaper loosely crumpled into rounded spheres. 6. Install a 155 degree residential quick response fire sprinkler head in the burn room; be sure to wrap the threads with

Teflon tape and only use the supplied sprinkler wrench to tighten. Other types of wrenches may damage the head. NO TORQUE PRESSURE NECESSARY. NO CONCEALED HEADS 7. Bleed air from pump by opening the priming valve/black handle on the side of the pump. Close the valve after air is expelled and only water is coming out through the drain tube. 8. Open PUMP TEST/MAIN DRAIN (normally closed) to verify the pump is primed and working properly prior to lighting any fires in the trailer. 9. Have an operator stand by the electrical controls and fire pump controls. i. This person is to operate the emergency deluge valve if there is insufficient heat generated to activate the sprinkler head or in the remote chance that the head does not operate. ii. If using the storage tank, turn the pump on at this point. This person will also operate the smoke removal fans immediately after the fire sprinkler activates. 10. Light the fire with a match, candle, or cigarette lighter. Protect your hand with a fire rated glove. 11. Immediately after the sprinkler head activates turn on the ventilation fans in the burn room. 12. Open the windows if necessary in conjunction with the exhaust fans to assist in ventilation. 13. Shut off the water supply to the sprinkler head when the visible fire is out. If using the storage tank, turn off the pump. If another burn is desired, begin again at Step #2. When completed with all of your live burns and prior to towing: Drain the tank utilizing the tank main drain. Return electrical cords into the trailer. Store the generator. Shut off all circuit breakers. Use the shovel and squeegee to clean the trailer so that it is ready for the next fire department. Report any problems or deficiencies to the Illinois Fire Inspectors Association (IFIA) at 847-756-4750 and/or to NIFSAB at (708) 403-4468. Materials available: Cloth (100% cotton or 100% unbleached muslin) Sprinkler Heads (135-155 residential quick response only!) Sprinklerman Coloring Books for children Flashover Charts/Residential Brochures for adults

How a Sprinkler Operates hard card Your New Home Should Have flyer C) Recommendations for the Public Education presentation: Equipment Available: -Spare residential sprinkler heads -Spare battery operated smoke detector - A large font digital clock Bullet Point Messages Residential quick response fire sprinklers operate 4 times faster than standard sprinklers of the same temperature rating preventing flashover. 82% of the fire deaths occur in a residential occupancy. Only the sprinkler closest to the heat of the fire will activate. Water spray from a residential quick response sprinkler head sprays water high on the wall to cool hot fire gases. SPRINKLER DEMO TALKING POINTS Fire Facts In 2006, there were 412,500 reported home fires in the United States, resulting in 2,580 deaths, 12,925 injuries and $6.9 billion in direct property damage. In the U.S., a home structure fire is reported every 76 seconds and someone dies from a home fire every 162 minutes. Nationally, in one- and two-family homes, the two most frequent causes of fires are cooking (30%) and heating equipment (22%). More than half of all home fire deaths in the U.S. resulted from fires were reported between the hours of 11:00 pm and 7:00 am. But only one-fifth (20%) of home fires occur between those hours. According to NFPA, more than a quarter (28%) of fatal home fire victims had a disability, an age-related limitation, or were impaired prior to the fire. According to NFPA, "two of every five fatal fire victims never wake up before being injured." Many people think the smoke from a fire will wake them up, but they are more likely to have a harder time waking because of the toxic smoke." A home fire becomes deadly in just three minutes.

Smoke Alarm Facts A U.S. telephone survey found that 96% of the households surveyed had at least one working smoke alarm. NFPA's 2007 U.S. Experience with Smoke Alarms report: "Sixty-five percent of home fire deaths occurred in homes without working smoke alarms..." 43% occurred in homes where no smoke alarms were present at all. 65% (or two-thirds) of reported home fire deaths result from fires in homes with no working smoke alarms. Working smoke alarms cut the risk of dying in a home fire in half. In homes with smoke alarms, 20% had none that worked. When smoke alarms fail, it is most often because of missing, disconnected, or dead batteries. Sprinkler Facts If you have a home fire and you have sprinklers installed, they will save your life. Sprinklers prevent flashover -- the point where everything in the room ignites. No one can survive flashover. Sprinklers have been saving lives for well over 100 years. Having working smoke alarms cuts your risk of dying in half. Having both smoke alarms and fire sprinklers cuts your risk by 82%, compared to having neither. Sprinklers are linked by a network of piping, usually behind your walls and ceilings. Sprinklers work independently. The high heat of flames causes a sprinkler to open and allow water to flow over the fire. Smoke cannot set off a sprinkler. An operating smoke alarm cannot set off a sprinkler. Only the high temperature of the fire can make them work. The sprinkler closest to the fire will activate. In home fires, usually only one sprinkler is needed to control or even put out the fire. Sprinklers work so fast, they only need to use a fraction of the water that fire hoses have to use in fires where there were no sprinklers. WE NOW HAVE: ( ) HOME PROTECTED BY SPRINKLERS ( ) TOWNHOMES PROTECTED BY SPRINKLERS ( ) CONDOMINUM UNITS PROTECTED BY SPRINKLERS Good Luck! Please send photos to the Illinois Fire Inspectors Association and NIFSAB!