more than a breaker it s a breakthrough Compact NSX



Similar documents
Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

Low voltage electrical distribution. Electronic trip units. User manual 09/2009

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Wiring diagrams. Compact NSX. Contents

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Catalogue. Merlin Gerin Compact LV circuit breakers and switch-disconnectors 80 to 3200A

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Circuit Breakers. Next Generation of Protection Capabilities

Number 1 in efficiency

ABB PSPS Erich Steinmann; Generator control-2013

RM4TG20 three-phase network control relay RM4-T - range V

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

The complete range of consumer switchboards and switchgear

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Sentron Series Circuit Breakers

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

SENTRON Switching and Protection Devices Air Circuit Breakers

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bimetallic Overload Relay Specifications

48 SERIES Relay interface modules 10 A

TX OPEN RS232/485 module

White paper. ABB solutions for switching and protection of low speed wind turbines

Tmax MCCBs. Molded case circuit breakers. Tmax

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

General information Circuit breakers for power distribution T1 T3

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Charge Controller CC611/CC612 Preliminary datasheet

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Manual motor starter MS116

Low Voltage Products. Switches Automatic Transfer Switches

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Specifying a Variable Frequency Drive s

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

PSR The compact range Description

Safety Relays ESM/ESM-F

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Breaking and protection devices

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

49 Series - Relay interface modules A. Features

Power Meter Series 700

R.C.C.B. s two-pole LEXIC

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Low and Medium Voltage Division Erlangen, February 18, New MCCBs for Increased Line Protection and Availability

THERMAL MANAGEMENT SOLUTIONS

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

mecotron Safety relay ESTOP-2 For emergency stop monitoring

More than just OK. Okken: Low voltage switchboard for electrical distribution and motor control

Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Manual Motor Starter MS 116 up to 16 A Technical Data

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Electrical Network Management System

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Type: DILM9 10(24VDC) Article No.:

User s Manual Before using the inverter, you need to read and save the safety instructions.

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Three-phase monitoring relay CM-PFE

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

Thermal-Magnetic Circuit Breaker M1-..

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Compact NS. LV circuit breakers from 630 to 3200 A. Network protection. Supervision. Compact

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Table of Contents. TransformerIQ FAQs 1

38 Series - Relay interface modules A

Technical catalogue SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

80 Series - Modular timers 16 A. Features

Safety automation solutions

The Application of Circuit Breakers to Reduce Downtime in Datacentres

Transcription:

Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A

Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever, the current situation compels each and everyone to achieve more while using less resources. As Global specialist in energy management, Schneider Electric innovates its new MCCB Compact NSX which is the optimum measurement and communication solution that meet your energy efficiency challenges through optimized energy consumption, increased energy availability and improved installation management. For the first time, you can monitor both energy and power, offering new performance in a remarkably compact device. Our main aim is to make energy safe, reliable and efficient.

Compact NSX more than a breaker Traditional breaker... @ Switch on/off the circuit @ Protection against: > overload, > short circuit, > earth leakage. @ Isolation The breakthrough... @ Combine safety & performance: > Roto active technology, > New breaking capacities. @ Monitoring and Management > Integrated monitoring for all electrical parameters (I, V, E THD,... etc), > Accessibility of Information. @ Better continuity of service > Improved discrimination, > Preventive maintenance. @ Added simplicity > Torque limiting screws, > Green ready led. @ Ease of communication

Combine safety and performance Compact NSX is innovative it incorporates monitoring and communication functions, from 40 amps upward, combined with perfect protection. 23 new patents pending confirm the innovative character of Compact NSX Expert technology A roto-active contact breaking principle provides better limitation and endurance performance: @ very high breaking capacity in a very small device, @ exceptional fault current limitation for extended system life. Reduced installation costs Achieve up to 30% savings: @ total discrimination is ensured particulary in the case of miniature circuit breakers for considerable savings at the time of installation, @ smaller devices mean more economical switchboards for a significant impact on overall cost of installation no need for over-calibration. NS400 NSX250 New breaking capacities New performance levels improve application targeting: @ 25kA standard low short-circuit level applications, e.g., in service businesses, @ 36-50kA standard applications (industrial plants, buildings and hospitals), @ 70-100kA high performance at controlled cost, @ 150kA demanding applications (marine). Enhanced protection for motors Compact NSX meets the requirements of IEC 60947-4-1 standards for protection of motors: @ well adapted to motor-starting solutions up to 315kW at 400V, providing protection against short circuits, overloads, phase unbalance and loss, @ set up additional protection systems for starting and braking with the motor running, reverse braking, jogging or reversing in complete safety, @ used in conjonction with a Schneider Electric contactor; Compact NSX complies with the requirements of so-called type 2 coordination. NS160 (100 A) NSX100 Multi 9

Monitoring & management Compact NSX is a single device, which contains a monitoring unit to control energy consumption and power. Integrated monitoring @ A Micrologic electronic tripping device with next-generation sensors: > an "iron sensor for the power supply to the electronics, > an "air" sensor (Rogowski coils) for the measurement part. @ The originality lies in how Compact NSX measures, processes and displays data, either directly on screen, on the switchboard front panel, or via a monitoring system. - 10 % Monitoring consumption can help reduce energy costs by as much as 10%. Accessibility of information To keep costs under control and ensure service continuity, relevant information must be available in real time: @ a kilowatt-hour meter helps optimise costs and their allocation, @ harmonic distortion rate shows the quality of electrical supply, @ alarm notification secures operational control and maintenance planning, @ event logs and tables, activated continuously, ensure the installed equipment base operates correctly, so energy efficiency is maximized. Installation supervision Used in conjunction with PowerLogic monitoring software, Compact NSX provides users with a set of parameters and tools to make it easy to monitor installations. ASIC Electronics (ASIC), independent of measurement, manage protection functions. The high degree of integration in electronics guarantees protection against conducted or radiated interference.

Better service continuity Compact NSX makes discrimination its main advantage in minimizing the impact of short circuits, ensuring service continuity for installations. Total discrimination @ With 30 years of experience and as an expert in discrimination, users can be sure of service continuity. Downstream circuit breaker trips as close as possible to the fault, so upstream circuit breaker is not overloaded. 100 % service continuity Service continuity Adding an SDX module remotes the trip or alarm condition of compact NSX breaker, ensuring total service continuity: @ The SDX module indicates tripping due to overload fault, @ The module can be assigned to overload pre-alarm function, @ The module indicates ground fault trip. Preventive maintenance Maintenance indicators provide information on the number of operations, level of wear on contacts and total load rates. Maintenance is now preventive, avoiding faults. Direct access to maintenance indicators

Added simplicity Compact NSX takes the principles of easy installation and use which made its predecessor so successful to a higher level. Simple in design @ Installers mount and wire Compact NSX in the same way as Compact NS, which makes engineering for a retrofit or extension simple. @ Integration in help software, for parameter settings and switchboard installation, eases design. Simple to install @ A Limited Torque Screw (LTS) system ensures proper installation of the tripping device, for added flexibility. @ A transparent sealed flap protects access to tripping device switches and prevents settings from being changed. @ New electrical control adjustment also has a transparent sealable cover to prevent it from being operated accidentally. Simple to use @ Users customise alarms for all parameters, assign them to indicator lights, choose display priorities, and configure time delay thresholds and modes. @ Continuously-activated event logs and tables, a wealth of information, enable users to ensure that the installed equipment base operates correctly, and to optimize settings. 65% time savings in installation compared with a classic monitoring solution. The green "Ready" LED flashes to show that all is well. LTS installation system Transparent protective cover

Ease of communication Pre-wired connectivity and plug and play interface modules allows easy integration with communication networking. BSCM Module Communication states and orders. Modbus IFM interface Interface with Modbus network. FDM 121 switch board display unit @ Direct access to essential information. @ Uses the sensors and processing capacity of the Micrologic. @ No special software or settings is required. NSX Plug and play cord cables Communication with switchboard display unit and/or the Modbus interface without parameter setting. Modbus IFM interface Modbus NSX cord FDM121 switchboard display unit Compact NSX + BSCM Module

Compact NSX, an optimum compitability with Ecodial V 3.4 Providing more expertise and time saving in your electrical design installations, Schneider Electric innovates special adapted software helping you to design solutions that meet the different business requirements. Ecodial V 3.4 is fully adapted to the local market The new version of the Ecodial is adapted for the Egyptian market & complies with the latest electrical standards. The selection of the electrical products & cables are complying with the local market needs. Cascading and discrimination calculations are based on the available sizes & ratings in the South African market. Ecodial V 3.4 new functionalities @ New ergonomics @ A cable summary is at your disposal @ The report now includes power sum results @ Improvement of the motor starter management @ Curve direct evolution: > save the tripping-curve and settings as an.rtf file > display the tripping-curves of thermal relays @ You can choose variable speed drives manually @ Ecodial V3.4 takes into account the tuning frequencies of detuning reactors as part of compensation Compact NSX Ecodial software Maximum control & energy measurement ; Ecodial V 3.4... your efficient assistant for electrical installations.

Compact NSX Characteristics Common characteristics Rated voltages Insulation voltage (V) Ui 800 Impulse withstand voltage (kv) Uimp 8 Operational voltage (V) Ue AC 50/60 Hz 690 Suitability for isolation IEC/EN 60947-3 yes Utilisation category A Pollution degree IEC 60664-1 3 Control Manual With toggle With direct or extended rotary handle Electrical With remote control Versions Fixed Withdrawable Plug-in base Chassis Circuit breakers Breaking-capacity levels Electrical characteristics as per CEI/IEC 60947-2 Rated current (A) In 40 C Number of poles Breaking capacity (ka rms) Service breaking capacity (ka rms) lcu AC 50/60 Hz 220/240 V 380/415 V 440 V 500 V 525 V 660/690 V lcs AC 50/60 Hz 220/240 V 380/415 V 440 V 500 V 525 V 660/690 V Durability (C-O cycles) Mechanical Electrical 440 V In/2 In 690 V In/2 In Characteristics as per Nema AB1 Breaking capacity (ka rms) AC 50/60 Hz 240 V 480 V 600 V Characteristics as per UL 508 Breaking capacity (ka rms) AC 50/60 Hz 240 V 480 V 600 V Type of protection and applications MA magnetic TM-D Micrologic 2 Micrologic 5 / 6 A or E thermal-magnetic electronic 5 A or E 6 A or E 6 E-M classe Distribution and motors Distribution Generators Distribution Service connection (public distribution) Generators Motors (I only) Motors Distribution and generators Distribution and generators Motors

>30A >95 % T 185 140 120 210 100 220 Ir (A).7.4.3 1.2 OFF Ig (x In) >30A Ir Cl. N Mode >95 % T 400 320 280 470 250 500 Ir (A).7.4.5.6.8.3.9.2 OFF Ig (x In) Isd 1/A 2/B 3/C Iunbal tunbal Ijam tjam Ig A test OK Ir Cl. Isd Iunbal tunbal Ijam tjam Ig tg Mode N 1/A 2/B 3/C tg A test OK Ii=6500A IEC60947-4-1 Ir 7.2Ir Class Isd NSX100 NSX160 NSX250 NSX400 NSX630 B F N H S L B F N H S L B F N H S L F N H S L F N H S L 100 160 250 400 630 2, 3, 4 2, 3, 4 2, 3, 4 3, 4 3, 4 40 85 90 100 120 150 40 85 90 100 120 150 40 85 90 100 120 150 40 85 100 120 150 40 85 100 120 150 25 36 50 70 100 150 25 36 50 70 100 150 25 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 20 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 130 15 25 36 50 65 70 15 30 36 50 65 70 15 30 36 50 65 70 25 30 50 65 70 25 30 50 65 70-22 35 35 40 50-22 35 35 40 50-22 35 35 40 50 20 22 35 40 50 20 22 35 40 50-8 10 10 15 20-8 10 10 15 20-8 10 10 15 20 10 10 20 25 35 10 10 20 25 35 40 85 90 100 120 150 40 85 90 100 120 150 40 85 90 100 120 150 40 85 100 120 150 40 85 100 120 150 25 36 50 70 100 150 25 36 50 70 100 150 25 36 50 70 100 150 36 50 70 100 150 36 50 70 100 150 20 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 130 7,5 12,5 36 50 65 70 15 30 36 50 65 70 15 30 36 50 65 70 25 30 50 65 70 25 30 50 65 70-11 35 35 40 50-22 35 35 40 50-22 35 35 40 50 10 11 11 12 12 10 11 11 12 12-4 10 10 15 20-8 10 10 15 20-8 10 10 15 20 10 10 10 12 12 10 10 10 12 12 50000 40000 20000 15000 15000 50000 20000 20000 12000 8000 30000 10000 10000 6000 4000 20000 15000 10000 6000 6000 10000 7500 5000 3000 2000 40 85 90 100 120 150 40 85 90 100 120 150 40 85 90 100 120 150 40 85 100 120 150 40 85 100 120 150 20 35 50 65 90 130 20 35 50 65 90 130 20 35 50 65 90 130 30 42 65 90 130 30 42 65 90 130-8 20 35 40 50-20 20 35 40 50-20 20 35 40 50-20 35 40 50-20 35 40 50-85 85 85 - - - 85 85 85 - - - 85 85 85 - - 85 85 85 - - 85 85 85 - - - 25 50 65 - - - 35 50 65 - - - 35 50 65 - - 35 50 65 - - 35 50 65 - - - 10 10 10 - - - 10 10 10 - - - 15 15 15 - - 20 20 20 - - 20 20 20 - - Circuit breakers and trip units COMPACT NSX 100/160/250 Ready Alarm 155 170 200.5.6.8 6.2 E-M Micrologic 220 MA Distribution and motors COMPACT NSX 400/600 TM-D Distribution TM-G Generators 2.2 Distribution 2.2-AB Service connection (public distribution) 2.2-G Generators 2.2-M Motors 5.2 A Distribution and generators 5.2 E Distribution and generators 6.2 A Distribution and generators 6.2 E Distribution and generators 6.2 E-M Motors Ready Alarm Micrologic 6.3 E-M 350 380 440 500 1.3-M Distribution and motors 2.3 Distribution 2.3-AB Service connection (public distribution) 1.3-M Motors (I only) 2.3-M Motors 5.3 A Distribution and generators 5.3 E Distribution and generators 6.3 A Distribution and generators 6.3 E Distribution and generators 6.3 E-M Motors

Schneider Electric South Africa (Pty) Ltd Head Office 1 River View Office Park, Janadel Avenue, Halfway Gardens, Midrand, 1685 Tel.: +27 (0)11 254 6400 http://www.schneider-electric.co.za As standard specifications and designs change from time to time, please ask for confirmation of the information given in this publication. SEE 98039 / E