Passion for electricity Cabling solutions for networks Cables, modules, applications and data centers Intelligent system and switch components I/O components, routers and switch cabinet components in cooperation with
System overview Category 6A Cat.6A, Cat.6 A? There is some confusion on the market as to the designations and the specifications of the Cat.6 A standard, as two valid standards apply to it. The specifications of the TIA/EIA (American standard) are characterized by less strict values and do not distinguish between the cabling section and the component. Everything is referred to as a category (Cat.) here. On the other hand, the ISO/IEC (international standard) distinguishes between cabling sections (Class) and the component (Cat.), and the specifications are more demanding. In addition, the two standards differ in the spelling of Cat.6A (TIA/EIA) and Cat.6 A or Class E A (ISO/IEC). The performance of a Cat.6 A channel link according to EIA/TIA is not comparable with the performance of a Class E A channel link according to ISO/IEC! If you want to make sure as a user that you obtain optimum cabling according to Class E A, then you must use the components of the Cat.6 A specification according to ISO/IEC. Independent certification The connection system complies with the international Cat.6 A standard and has been tested and certified by an independent accredited test laboratory according to ISO/IEC 11801 Ed.2.2 5 (FPDAM 2009-04), TIA/EIA-568-C.2 (2009-08) and IEC 60603-7-51 Ed.1 (12/2008). The requirements for Class E A are also complied with in the permanent and channel link according to the standard specified above. 2 Passion for electricity
Installation cables Category 6 A, Category 7, Category 7 A GC1500 pro22 Cat.7 A S/FTP 4P LSHF-FR AWG22 S/FTP Applicable standards: EN 50173-1:2011-09; ISO/IEC 11801 Ed.2.2:2011-09; EN50288-4-1; IEC61156-5 and IEC61156-7 Flame retardance: IEC60332-1; IEC60332-3-24; IEC 60754-2 and IEC 30034 GC1200 pro22 Cat.7 A S/FTP LSHF-FR AWG22 S/FTP Applicable standards: EN 50173-1:2011-09; ISO/IEC 11801 Ed.2.2:2011-09; IEC 61156-5 and IEC61156-7 GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR AWG23 S/FTP Applicable standards: EN 50173-1:2011-09; ISO/IEC 11801 Ed.2.2:2011-09; EN50288-41; IEC61156-5 and IEC61156-7 GC1000 plus23 Cat.7 S/FTP LSHF AWG23 S/FTP Applicable standards: EN 50173-1:2011-09; ISO/IEC 11801 Ed.2.2:2011-09; IEC61156-5 and IEC61156-7 GC600 F1 23 Cat.6 A U/FTP 4P LSHF AWG22 S/FTP Applicable standards: EN 50173; ISO/IEC 11801 and EIA/TIA 568A C6 A modul 180 and C6 A modul K 180 Modul cut-out Keystone cut-out C6Amodul 180 and C6Amodul K 180 Modular termination unit RJ45 Certified GHMT Cat.6 A re-embedded PVP Component testing for Cat.6 A to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09, TIA/EIA-568-C.2 (2009-08) and IEC 60603-7-51 Ed.1 (12/2008), certified to GHMT Compliance with class E A up to 500 MHz to ISO/IEC 11801 Ed.2.2:2011-06, class E A EN 50173-1:2011-09 Tested: component up to 600 MHz, link up to 800 MHz For 10 GBit Ethernet (IEEE 802.3an) Suitable for Power over Ethernet (PoE, PoE plus and UPoE) Easy to install connection of data lines AWG 26/1 to 22/1 (solid wire) and AWG 26/7 to 22/7 (stranded wire) to insulation displacement connectors (IDC) Intelligent cable management in stuffer cap - also suitable for heavily twisted cables Conductor assignment to T568A and T568B is directly printed on the stuffer cap Solid, one-piece and reusable module housing refined with zinc die-casting Mounting without special tools; strain relief directly snapped on to stuffer cap Mounting version: Modul cut-out, cable feed 180, 270 or 90 Keystone cut-out, cable fee 180, 270 or 90 Passion for electricity 3
Assembly scheme C6 A modul 180 and C6 A modul K 180 1 2 3 8 7 2 1 5 4 3 6 Assignation des brins PIN No. T568A T568B 1 WH-GN WH-OG 2 GN OG 3 WH-OG WH-GN 4 4 BU BU 5 WH-BU WH-BU 6 OG GN 7 WH-BN WH-BN 8 BN BN Equipped and unequipped applications 19 Module frame 1RU aluminum/black unequipped REGplus IP20 C6 A modul 180 & C6 A modul 270 Modul IP44SG surface mounting housing unequipped Lockable flush-mounted IP44 outlet, with two keyswith lock with instantaneous locking action (identical locks and keys) Cover closes completely, even when patch cables are plugged in For two individual modules in Modul design (not suitable for OpDAT modules) Ball-throw proof according to DIN 18032 Can be operated with standard patch cables Clearly visible nomenclature panel Bottom section of housing can be turned 180, with cable feed possible from top and bottom With space to install the required spare cable lengths Gray Keystone wall outlet AP surface mounting unequipped Very compact 1-port surface-mounted termination unit for one individual Keystone module Module plug direction 90 downwards Strain relief with cable tie at the module Label window for identification labels (labels included in the delivery) Integrated dust protection shutter Cover parts in color similar to pure white RAL 9010, glossy surface Not suitable for 180 couplers (anti-bend sleeves for patch cables usually too long) Variants: 1 port, 2 ports 4 Passion for electricity
Equipped and unequipped applications Patch cable Cat. C6 A AWG26 Fully shielded Cat.6 A patch cable AWG 26/7 Two shielded RJ45 connectors; 1:1 assignment Class E A Link up to 500 MHz to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09 Suitable for 10 GBit Ethernet (IEEE 802.3an) Molded snagless anti-bend sleeve -coated in cable color with integrated lock hook protection Halogen-free Colors may differ slightly due to different protection lots Keystone wall outlet for 6/12 port surface mounting Very compact 6/12-port surface-mounted termination unit for six/twelve individual Keystone modules Module plug direction 90 downwards Strain relief with cable tie at the module Cover parts in color similar to pure white RAL 9010, glossy surface With shielded modules suitable for 6 modules C6 A Module 270 Surface-mount or flush-mount termination unit with C6 A modul 270 Certified to GHMT Cat.6 A re-embedded PVP Component testing for Cat.6 A to ISO/IEC 11801 E.2.2:2011-06, DIN EN 50173-1:2011-09, TIA/EIA-568-C.2 (2009-08) and IEC 60603-7-51 Ed.1 (12/2008), certified to GHMT Compliance with class E up to 500 MHz to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09 Tested: component up to 600 MHz, link up to 800 MHz for 10 GBit Ethernet (IEEE 802.3an) Suitable for Power over Ethernet (PoE, PoE plus and UPoE) Connection of data lines AWG 26/1 to 22/1 (solid wire) and AWG 26/7 to 22/7 (stranded wire) to insulation displacement connectors (IDC) Module plug direction 45 downwards Strain relief snapped on to stuffer cap With label window for enclosed identification labels Label sheet 209 x 294 mm Integrated dust protection covers (also colored) Cover parts in pure white RAL 9010, structured surface with matt finish C6A RJ45 field plug pro 180 Cat.6A class EA RJ45 plug to be assembled in the field (fully shielded and multi-port capable) Compliance with class EA to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09 10 GBit suitable according to IEEE 802.3an Straight (180 ) cable feed Easy assembly - connection without special tools Wire connection: stranded wire AWG 27/7 to 22/7, wire diameter from 0.46 to 0.76 mm Wire connection: solid wire AWG 26/1 to 22/1, wire diameter from 0.4 to 0.64 mm C6A RJ45 field plug pro 360 Cat.6A class EA RJ45 plug to be assembled in the field (fully shielded and multi-port capable) Compliance with class EA to ISO/IEC 11801 Ed.2.2:2011-06, DIN EN 50173-1:2011-09 10 GBit suitable according to IEEE 802.3an Variable (360 ) cable feed, freely selectable Easy assembly - connection without special tools wire connection: stranded wire AWG 27/7 to 22/7, wire diameter from 0.46 to 0.76 mm wire connection: solid wire AWG 26/1 to 22/1, wire diameter from 0.4 to 0.64 mm Passion for electricity 5
System overview Fiber optic Performance classes fiber optic cable Multimode Singlemode Standard IEC 11801 OM2 OM3 OM4 OS2 IEC 60793-2-10 A1a.1 ITU-T 60793-2-10 A1a.2 6073-2-10 A1a.3 60793-2-50 B6_a / B6_b G.657.A2/B2 Type of fiber 50/125 µm 50/125 µm 50/125 µm 9/125 µm Attentuation 850 nm 2,7 db/km 3,0 db/km 3,0 db/km 1300 nm 0,8 db/km 1,0 db/km 1,0 db/km 1310 nm 0,38 db/km 1550 nm 0,23 db/km Bandwidth (OFL) 850 nm 500 MHz.km 1500 MHz.km 3500 MHz.km 1300 nm 500 MHz.km 500 MHz.km 500 MHz.km Bandwidth EMB) 850 nm 2000 MHz.km 4700 MHz.km Fiber performace Singlemode OS2 Multimode OM1 Multimode OM2 Multimode OM3 Multimode OM4 10-gigabit transfer 2000 m 33 m 86 m 300 m 550 m OpDAT installation cables Universal cable (U-DQ(ZN)BH): Loose tube cable for interior and exterior with 4, 8, 12, 24 or 48 fibers (0.25 mm) Mini breakout cable (U-VQ(ZN)H): Cable for interior and exterior, with 4, 12 or 24 wires (0.9 mm) Breakout cable (I-V(ZN)HH): Interior cable with 2 cables All cable jackets LSHF (low-smoke, halogen-free) Fiber types: OM2, OM3, OM4, OS2. All fibers are bend insensitive. OpDAT patch cables & pigtails Assembly with all variations of plug types LC, SC and ST. Other plug types on request. Fiber types: OM2, OM3, OM4, OS2. Patch cable (Duplex, Figure 8) with outer diameter 2.0 x 4.2 mm. Cable jacket LSHF-FR (low-smoke, halogen-free, flame-retardant). Available in different lengths, maximum length 20 m Pigtails with compact wire 0.9 mm, length 2 m, primary and secondary coating (0.25 mm / 0.9 mm) same color. Available as individual pigtail or in a set of 12. 100% optically inspected for insertion and return loss. Test reports are enclosed. OpDAT pre-assembled installation cables Assembly with all variations of plug types LC, SC and ST. Other plug types on request. Three cable versions: Universal cable: Loose tube cables for interior and exterior with up to 48 fibers (0.25 mm), Mini breakout cable: Cable for interior and exterior with 4, 12 or 24 wires (0.9 mm) Breakout cable: Interior cable with 2 cables (2.1 mm) Fiber types: OM2, OM3, OM4, OS2. All fibers are bend insensitive. Customized manufacture, maximum length 1000 m. 100% optically inspected for insertion and return loss. Test reports are enclosed. OpDAT patch panels Fiber optic patch panels for 19 inch technology, 1 rack unit (RU) Lightweight aluminum construction Fitted with pigtails and couplers (screwed) Service-friendly mounting through snap-on cover or removable drawer Splice trays with pigtails and crimp splice holders prepared ready-to-splic Pigtails cleaned and plugged into couplers Assignment according to color code to IEC 60304 Available with SC-Duplex, LC-Duplex and ST couplers. Other types on request. 6 Passion for electricity
Intelligent system composants Highly communicative and decentralized control Bus modules C Logline stands for intelligent system composants for a highly communicative and decentralized control in the application and products areas building automation, measurement and monotoring relays, interface modules, industrial relays and telecommunication. LON I/Os CAN-bus I/Os M-Bus I/Os Ethernet I/Os BACnet I/Os MOD-Bus I/Os MR-DIO4/2-IP LF-AI8 FRAS 4/21 MOXA EtherDevice Switch 8 Port Interface modules KRA-SRA-F10/21 RM3-2W 24 V DC ADU-C12 R274-4 changeover contacts (DPST) ADU-C12 Time, measurement and monotoring relays MR-DIO4/2-IP LF-AI8 Passion for electricity 7
Compact solutions for data centers The heart of every network is its data center. The type of processed data ranges from simple text documents up to complex design drawings, from production control systems up to building management plans. And the requirements in terms of performance and capacity rise exponentially. Networks soon reach their limits in the light of the extreme large data volumes that must be processed and archived today so that they must again and again be extended. And in those cases compact, inexpensive and quick solutions must be provided that use the available space in ideal fashion and reduce immobilization times to the absolute minimum. The compact solutions from METZ CONNECT in copper (Cat.6A) and FO are exactly tailored to the demands arising from data centers. The DataCenterCompactSolution (DCCS) excels not only by its high packing density, its low installation works and costs (pre-assembled RJ45 and FO plugs) but also by its Plug & Play design. This pre-assembled and measured system prevents installation errors. With this solution also jammed cable lines are a matter of the past. This optimizes the transparency and reduces the risk of heat accumulation. The use of DCCS installation cables leads also to a significant reduction of the thermal load. The following pages present all those numerous products and systems, which will help you to prepare also your data center for the next challenges. DCCS 6 x LC-D Link Prefabricated fiber optic link consisting of 2 subassembliesdc- CS2 with 6 LC-D couplers mounted to a 12 fiber mini breakout cable Port numbering of the DCCS2 19 subassembly frame remains in place when installing the FO subassemblies For 10 GBit Ethernet (IEEE 802.3an) The locking levers of patch cords connected to DCCS2 subassemblies show upwards and are easy to handle at any time Solid and refined assembly housing Cable diameter less than 6,5 mm Delivery with serial number and 12 attenuation measurements reports Mounting version: DCCS2 Available in prefabricated, customer specific lengths Maximum length: 500 m Configuration tool in Microsoft Excel available on request Variants: SM (OS2), SM (OS2 APC), MM (OM4), MM (OM3) DCCS2 fiber optic MPO link Pre-assembled fiber optic link consisting of one MPO plug on each side and a 24-fiber connection cable For up to 10 GBit Ethernet (IEEE 802.3an) 9 = 12 fibers E9/125 OS2 5 = 12 fibers 50/125 OM3 7 = 12 fibers 50/125 OM4 0010 = 1.0 m 0015 = 1.5 m 0050 = 5.0 m 0100 = 10.0 m 0150 = 15.0 m 0200 = 20.0 m 0995 = 99.5 m 1000 = 100.0 m 5000 = 500.0 m Fiber type Length 130D2F X MP X XXXXX E Allocation A = Polarity, method A B = Polarity, method B C = Polarity, method C 8 Passion for electricity
Polarity, method A Module Key up to Key up Key up Key Down A-to-B Patch cord Position 1 Position 1 A-to-B Patch cord Key up to Key up Key up Key Down Position 1 Position 1 Module Polarity, method B Module Key up to Key up Key down to Key down A-to-B Patch cord Position 1 Position 1 A-to-B Patch cord Key down to Key down Key up to Key up Position 1 Position 1 Module Polarity, method C Key up to Key up Module Key up to Key down A-to-B Patch cord Position 1 Position 1 A-to-B Patch cord Key up to Key up Key up to Key down Position 1 Position 1 Module Passion for electricity 9
Industrial cabling IP protected connectors The Fit-for-All principles Benefit from maximum flexibility! This range of products does not only offer decisive advantages for your industrial applications but also for their planning, assembly and their daily use. All housings are designed to the protection degree IP67. Simply select your type of application and your desired material. You may choose between plastic and metal. Same color dot = combination possible. Plug inserts Plug housing Flange housing Flange inserts Industry IP67 V1 metal plug housing * Industry IP67 V1 metal bulkhead * Modul RJ45 Magnetics E-DAT Industry RJ45 plug insert * E-DAT Industry RJ45 coupler insert * Industry IP67 V1 plug housing * Industry IP67 V1 bulkhead * E-DAT Industry RJ45 field jack * E-DAT Industry RJ45 field plug insert * Industry IP67 V4 plug housing * Industry IP67 V4 bulkhead * OpDAT Industry SC-RJ/2SC adapter insert * OpDAT Industry 2SC plug insert * OpDAT Industry LC-D adapter insert * Industry IP67 V5 metal plug housing * Industry IP67 V5 metal bulkhead * OpDAT Industry 2LC plug insert * LC-D SFP Transceiver Industry IP67 V14 plug housing * Industry IP67 V14 bulkhead * E-DAT Industry USB A coupler insert * 10 Passion for electricity
Ethernet M12 Ethernet M12 round connectors The Ethernet M12 plug is an industrial plug of the round plug category; it has a metrical M12 thread 1. The METZ CONNECT Ethernet M12 plug series has been especially designed and compiled for data transmission systems in industrial environments. METZ CONNECT offers 2-pair twisted-pair connectors M12 with D-coding and 4-pair twisted-pair connectors M12 with X-coding. The 4-pole Ethernet M12 plug with D-coding offers a transmission ratio of 100 MBit/s. For higher data transmission ratios up to some Gigabits (e. g. 10 Gigabit), we offer 8-pole Ethernet M12 plugs with X-coding. The rugged Ethernet M12 plugs excel by their extremely strong mechanical and electrical resistance. In addition they are resistant against dirt and humidity once they are plugged in (IP67). This ensures safe contacts and a trouble-free data transmission. M12 field plug straight M-coded plug based on IEC PAS 61076-2-109 and suitable for field packaging 10 GBit suitable according to IEEE 802.3an Suitable for Power over Ethernet (PoE, PoE plus and UPoE) 8-wire M12 plug for AWG 22 to be assembled in the field Connection of AWG 26/7-22/7; AWG 24/1-22/1 possible Solid copper wire diameter from 0.4 to 0.64 mm Stranded copper wire diameter from 0.48 to 0.76 mm Conductor diameter up to 1.6 mm Cable jacket from 5.0 to 9.7 mm Consists of only 2 parts Easy assembly - connection without special tools Zinc die-cast housing for industrial use Passion for electricity 11
Telec Belgium Passion for electricity Rue des Rivageois 1A 4000 Liège Belgium Phone: +32 (0)4 252 75 73 Fax: +32 (0)4 252 70 14 cable@telec.be www.telec.be Telec Luxembourg Passion for electricity Rue de Marbourg 19 box 3 9764 Marnach Luxembourg Phone: +352 (0)245 193 21 Fax: +352 (0)245 193 33 cable@telec.lu www.telec.lu Passion for electricity