1 PURE : REliable planning of data center cabling
2 THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for data centers. It eliminates two uncertainty factors that are critical to overall performance in day-to-day operations: UncERtaintY FACTOR: contamination By their very nature, the optical contacts integrated in PURE interfaces make it impossible for contamination or damage to occur during installation. The LC-Duplex interface is sealed at the factory. You just snap it into the back of the front panel. UncERtaintY FACTOR: loss BUdgET PURE connectors have an extremely low, guaranteed insertion loss not just in eachto-each tests, but in real-world applications. This gives you certainty in the planning of transmission paths and allows you to implement more connections per channel. PreconnEct PURE will help to keep your data center running smoothly over the long term. But that s not all. Read the following pages to learn about details and additional features. PURE at A GLANCE Integration of optical contacts in the LC-Duplex interfaces: ruling out contamination during installation Guaranteed parameters for unused channels until they are actually used Factory-sealed to prevent improper opening and handling Insertion loss and return loss exceeding IEC Ed. 1.0 CD Grade Cm (multimode) Guaranteed maximum insertion loss of 0.4 db (application limit, LC multimode 50 µm) Mean insertion loss = 0.15 db (lc multimode 50 µm) Visual quality of ferrule end faces significantly better than IEC Quick, tool-free mounting with simple snap-in on the back of the panel Complete system consisting of trunk cables, patch cables, SMAP-G2 panels and racks Multimode and single mode * In relation to 1.0 db insertion loss, a channel length of 150 m and a loss budget of 1.54 db according to original Fibre Channel 16 Gb/s OM4 specification. 2/3 2/3
3 Dust cap with nipple Completely redesigned interface Seal Shutter PURE INNOVation: NO MORE CONTAMination, no MORE UncERtaintY ABOUT attenuation CLEan CONNEctionS: for ABSOLUTE CERtaintY Studies have shown that about 50% of all network errors are caused by cabling problems. Of these, most involve contamination of fiber-optic cable connections, improper patching or even damage arising from patching. PreconnEct PURE eliminates these causes from the start. PURE trunk cables have preassembled PURE interfaces instead of conventional connectors. The optical contacts integrated in the interfaces are factory-tested for perfect optical quality and absolute cleanliness before the seal is applied. On the patch side the LC-Duplex interfaces are sealed with protective caps, preventing contamination even if the channels are not used for a long time. The warranty permits opening of seals and patching only by certified personnel (see also page 14/15, Cabling Services). In this way PURE not only ensures maximum data transmission over long distances, it saves time and costs by at least 15%, because on-site acceptance tests and cleaning are unnecessary. insertion LOSS: APPlication LIMIT VERSUS PRODUction limit An increase in transmission speed always means a reduction in the maximum permissible attenuation of multimode links. In high-end applications it is therefore essential to keep the insertion loss of fiber-optic connections as low as possible. To impress customers, cable manufacturers often quote the so-called production limit value, which is measured using reference couplers and connectors. But this value is of no relevance to actual practice, in which standard components with varying specifications are involved. OVERAlL PRocESS CAPabilitY PURE CONNEctoRS Frequency of measurement results For this reason Rosenberger OSI always quotes the so-called application limit value for PURE. This value applies to any combination of connectors, and it s guaranteed. The value is 0.4 db*, which is 0.2 db better than the highest performance class specified in IEC Ed. 1.0 CD Grade Cm (see also page 6). The mean* insertion loss (il) measured for PURE components is well below this, at 0.15 db (see Overall process capability chart). This gives you a big safety margin from the application limit value. In actual practice even better values are achieved. Application limit The connection does not have to be opened during installation; thanks to the new interface design, the complete unit can be snapped into the panel from behind. MAXIMUM INSERtion LOSS PURE IEC standard* Insertion loss in db 0.2 *IEC Ed. 1.0 CD Grade Cm /5
4 Overall performance: iec ed. 1.0 cd grade cm VERSUS pure The performance parameters for fiber-optic connections are set forth in the IEC and standards, which define grades. The highest performance class for multimode fibers is IEC Ed. 1.0 CD Grade Cm, which specifies a maximum insertion loss (il) of 0.6 db for 97% of the connections and a minimum return loss (RL) of 20 db. PreconnEct PURE significantly exceeds both of these values: COMPARISON OF MAXIMUM CHannEL LENGTHS* 150 m for IEC Ed. 1.0 CD Grade Cm INStallation: tool-free AND EaSY PURE trunk cables are preassembled with lc-duplex interfaces at both ends and sealed. Thanks to the newly designed interface with an innovative locking mechanism, each channel can easily be snapped from behind into the part front plates of the SMAP-G2 panels. PURE versus IEC Ed. 1.0 cd Grade Cm IL PURE Quality 50µm MM»Application limit«100% max. 0.4 db Mean 0.15 db IEC Ed. 1.0 CD Grade Cm (Grades Am & Bm are not covered by standards, RL Grade 2m) 97% max. 0.6 db Mean 0.35 db RL min. 40 db min. 20 db 165 m for PreconnEct PURE CoMParison of PoSSible connections* With maximum IL (0.4 and 0.6 db respectively) Cladding Core VISUal QUalitY OF THE FIBER SURfacES: in A CLASS OF ITS OWN Every connection between two optical fibers can impede the propagation of light in the channel. To minimize insertion loss it is therefore essential for the fiber ends to meet exactly and for the end faces to have as few imperfections (scratches and defects) as possible. By exercising the utmost care in manufacturing we achieve visual quality results for our PURE interfaces that are well above the requirements of IEC Thus, for any given loss budget, PreconnEct PURE permits up to twice as many connections per channel as with IEC-specified cabling. In addition, the high quality of Rosenberger OSI OM4 fibers allows elongated channel lengths (see illustration at right). 1 connection for IEC Ed. 1.0 CD Grade Cm VISUal QUalitY OF End FACES 2 connections for PreconnEct PURE PURE end faces without scratches and contamination ZONE SPEcification SCRatcHES DEFECTS With mean IL (0.15 and 0.35 db respectively) A: core 0-65 µm PURE MM No scratches > 2 µm No defects permitted IEC MM No scratches > 3 µm Up to 4 defects < 5 µm 2 connections for IEC Ed. 1.0 CD Grade Cm Fiber end faces with scratches and moderate contamination B: cladding µm PURE MM No scratches > 3 µm Up to 5 defects < 3 µm IEC MM No scratches > 5 µm Up to 5 defects < 5 µm 6 connections for PreconnEct PURE 6/7 * Example: Fibre Channel 16 Gb/s OM4
5 PURE products: a perfect product line Technical Data PREconnECT Fiber Trunks CABLE Design StRANDED mini loose tubes Numbers of fibers, max LEG LENgtH STEPPED [cm] approx PreCONNECT PURE Trunk Application Infrastructure cabling of data centers ProPERtiES Both sides factory assembled Standard light propagation channelwise crossed Cable length up to 2,000 m, longer on request Length Definition Order length: length between the connectors at the longest legs at both sides (not between the cable dividers) Length tolerances: up to 10 m = +/- 50 cm 11 m to 30 m = +/- 100 cm 31 m to 100 m = +/- 150 cm longer than 100 m = +/- 2% Leg lengths on both sides stepped acc. to table on page 9 Cable Types With all standard loose tube cables up to 144 fibers available Cable data sheets on request FibER Types OM4 and SM Fiber data sheets on request interface lc-duplex with shutters Optional Cable with increased tensile strength and crush resistance Cable with special armoring DeliVERY FoRM Factory measured IL and RL, including measurement report Product ID labels behind both cable dividers Dependent on the length as cable ring, on cardboard or wooden drum outer [mm] MAx. TensILE StRENgth [N] MAX. crush resistance [N/dm] MIN. blending radius [mm] static dynamic fire load [MJ/m] Part numbers number of fibers / INtERfACEs SM APC 8 9/125 G.657.A OM4 50/125 BI 36 lc-duplex 024P0141 G657 A 024P0101 OM4 48 lc-duplex 024P0126 G657 A 024P0103 OM4 72 lc-duplex 024P0142 G657 A 024P0105 OM4 96 lc-duplex 024P0128 G657 A 024P0107 OM4 144 lc-duplex 024P0129 G657 A 024P0109 OM4 Other interfaces, fiber types and numbers of fibers on request /9
6 PreConnect PURE PaTChCORds Applications Patchcords appropriate for use in data centers ProPERtiES Optimized kink and crush resistance with regards to application requirements Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request Standard light propagation: Full-duplex cables: duplex connectors at both sides acc. to ISO/IEC and EN = crossed Length TolerancES Up to 1 m = +/- 50 mm 2 m to 3 m = +/- 100 mm 4 m to 25 m = +/- 200 mm longer than 25 m = +/- 1% DUPLEx PatCHCoRD Cable type round I-V(ZN)H 2,0 mm FRNC-LSZH part numbers cable types Different FRnc-LSZH cables Cable data sheets on request FibER types OM4 und SM, bend-insensitive Fiber data sheets on request ConnectoRS lc-compact DeliVERY form Factory measured IL and RL, measurement report on request Serial number label at both cable ends for use in network documentation Product ID label on the package Each packed in a foil bag, cables longer than 100 m on cardboard drum DUPLEx PatCHCoRD Cable type round I-V(ZN)H 2,8 mm FRNC-LSZH part numbers connector LENgth SM APC 8 9/125 G.657.A1 OM4 50/125 BI lc-compact» LC-Compact Variable 087P6609 G657 A 087P6601 OM4 Other plug connection, cable- and fiber data on request. part numbers DUPLEx PatCHCoRD Cable type double-jacket-round I-V(ZN)H(ZN) 2,8/5,0 mm FRNC-LSZH connector LENgth SM APC 8 9/125 G.657.A1 OM4 50/125 BI lc-compact» LC-Compact Variable 087P6612 G657 A 087P6613 OM4 Other plug connection, cable- and fiber data on request. connector LENgth SM APC 8 9/125 G.657.A1 OM4 50/125 Bi lc-compact» LC-Compact Variable 087P6622 G657 A 087P6623 OM4 Other plug connection, cable- and fiber data on request. 10/11
7 19 SMAP-G2 PURE DISTRIBUTION PANEL PURE PaTCh location rack Applications For installation in 19 racks To interconnect e.g. PreconnEct PURE Trunks with patchcords in data centers ProPERtiES Maximum modularity and flexibility due to application-specific combinable 1/2 and 1/4 part front plates Very robust panel at low weight Suitable to accept all cables assembled by Rosenberger OSI 1 to 5 HU assembled with 1 HU 1/2 or 1/4 part front plates (PFP) depending on the number of fibers and coupler type Matrix numbering of the PFPs: Part numbers Single CoMPonents 19 SMAP-G2 PURE distribution panel To accept SMAP part front plates, 1 HE 2 HE 3 HE 5 HE SMAP-G2 PURE 1/4 PARt front plate BLIND PARt front plate P channels within PFPs are labeled 1 to n, PFPs within the panel are labeled 1 to n with clips Material and color: Front: steel, powder coated Body: aluminum Back planes: steel, powder coated DeliVERY FoRM Completely factory assembled without couplers. Coupler interfaces on trunk P P P P APPlicationS High density data center infrastructures To build passive data center patch locations with highest density PROPERtiES Innovative barrier-free cable management system No rack pillars that interfere with cable routing due to cable managers being integrated into the pillars Covers of the cable managers are hinged in both directions and completely removable Several perforated feedthroughs in the side and rear walls of the cable managers for easy cable routing in the vertical and horizontal direction Professional routing of large cable volumes from patchfields and storage of cable overlength inside the vertical cable managers Particularly suitable for FO cables due to cable retainers (L-Fingers) and Finger-Slots The rounded L-Fingers ensure high bending and kinking protection for the cables even under tensile load L-Fingers do not have sharp edges and are very robust and break resistant Cables can neither be squeezed nor kinked for there is enough space within the finger-slots During work with open or removed covers the L-Fingers hold the cables back in the finger-slots Dimensions (h x d x w): 213 (46 HU) x 90 x 90 cm Material and color: steel, powder coated, Optional 19 intermediate rack to build rack rows with an uneven number of racks on request DELIVERY FORM Factory mounted on a pallet (total height with pallet and packaging = 230 cm) Incl. adjustable pedestals for on-site mounting NUMBER OF CHANNELS / FIBERS INTERFACES TYPE 19 SMAP-G2 PURE DISTRibUtion PanEL with 1/4 part front plates 12K / 24F LC-Duplex P SMAP-G2 PURE 1/2 PARt front plate BLIND part Front PLAte P NUMBER OF CHANNELS / FIBERS INTERFACES TYPE 24K / 48F LC-Duplex P PART NUMBERS P Other interfaces and numbers of fibers on request. 12/13
8 Maintaining PURE QUalitY: WITH ROSEnbERGER OSI cabling SERVICES THE ADVantagES FOR YOU: You ensure consistent PURE transmission quality over the long term You minimize technical downtimes by relying on experienced specialists You relieve your technical staff of work unrelated to your core business You obtain quick, expert help in an emergency You can plan with confidence on the basis of fixed, foreseeable costs PURE interfaces are guaranteed to be absolutely clean all the way to completion of trunk cable installation. But what happens when they are to be connected? The moment the seal is removed and the protective caps are taken off for connecting a patch cable, the end faces of the fibers can be soiled or damaged if the connector is improperly handled. For this reason our warranty for insertion loss in PURE connectors is valid only if patching is carried out by Rosenberger OSI Cabling Services or certified service providers. We ensure that your project stays on track in each phase of implementation: Cabling Design Advisory services Conception and planning Training and workshops Cabling Installation Installation and mounting Project management and site supervision Quality assurance THREE LEVELS TO ENSURE MAXIMUM PERfoRMance Each data center is different. The requirements relating to performance, security and availability of expert knowledge can vary widely. For this reason Rosenberger OSI BASIC: For midsize companies with small server rooms The most important standard services for basic operation Provision of a technical hotline Implementation via individual contracts The Premium Plus level gives you a choice of eleven service modules in four service areas. From channel qualification to considerably gives you three different service levels to choose from. We have developed them for you based on more than 20 years of experience in the operation of data centers. Premium: For high-performance data centers Including on-site availability of experts and technicians Extended warranty for installed Rosenberger OSI products Implementation via fixed monthly payments Premium PLUS: For high-performance data centers with maximum availability Custom warranty and service Customer-specific activities Implementation via fixed monthly payments extended warranty periods, this is the ultimate in professional cabling management for data centers. With PreconnEct PURE and Rosenberger OSI Cabling Services you can be sure of getting maximum cabling performance over the long term and finally you can ensure a reliable planning of data center cabling. Managed Cabling Basic services for data center operation Guaranteeing of resources Additional services as needed 14/15
9 Rosenberger OSI GmbH & Co. OHG Endorferstr. 6 D Augsburg Telefon: +49 (0) Telefax: +49 (0)
Product Information 19 / 45HU Data-Center-Rack (Cabinet)
The Rosenberger-OSI Data-Center-Rack has been developed especially for FO patch distributors in Data Centers. In Data Centers the requirement for highest density becomes increasingly more important than
BLINK Triple-Play Connector
An innovative optical connector tailored to residential requirements forms the basis of the HUBER+SUHNER Fiber In The Home portfolio. Increased protection against soiling of the connector end surfaces,
12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)
1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled
Polymer Coated Fiber Cable (PCF)
Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability
Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8
Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,
1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.
Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment
Best Practices for Ensuring Fiber Optic System Performance. David Zambrano
Best Practices for Ensuring Fiber Optic System Performance David Zambrano Inspect Before You Connect Optical Connectors in our Networks Contamination and Signal Performance Sources of Contamination Process
LANC Fibre Patch Panel Solution
features and benefits Modular front with interchangeable fibre optic adapter modules Quick mount feature (teardrop design) Port numbers printed above and below adapter modules High-density using LC connectivity
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
MPO. Fast Fibre Solution for Data Centres
MPO Fast Fibre Solution for Data Centres Benefits The Plug & Play MPO solution of Nexans Cabling Solutions provides a comprehensive line of pre-terminated and pre-tested assemblies to meet the current
BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.
FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in
IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
Accelerating Light. Copper Cabling Solutions. Category 6A
Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity
AMP NETCONNECT Data Center Cabling Solutions
AMP NETCONNECT Data Center Cabling Solutions Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision
DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)
DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS) Double Jelly Filled Stainless Steel Tube General Description This document specifies non armour sensing fiber cable with double stainless
HUBER+SUHNER AG Phil Ward
The challenges of building and maintaining Fiber Optic connectivity in the modern Data Center HUBER+SUHNER AG Phil Ward What is our common Global Objective? To connect different types of equipment together
Fiber Optic Specifications
Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will
Migration Strategy for 40G and 100G Ethernet over Multimode Fiber
Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach Dennis Manes, RCDD Senior Applications Engineer Leviton Network Solutions E/8 #2509 Table of Contents Introduction 3 Types of
How To Make A Fibre Cable For A Data Centre
LANmark-OF Fibre Optic Solutions for Data Centres Complex Data Centres require fibre solutions CORE SWITCH ACCESS SWITCH SERVER SAN SWITCH LANmark-OF Slimflex Patch Cords LANmark-OF Single Mode LANmark-OF
Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution. www.commscope.com
Design Guide SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution www.commscope.com Contents Introduction 3 How Does a TAP Work? 3 The TAP Ecosystem 4 InstaPATCH 360 TAP Module Family 4 InstaPATCH
ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6
050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY
R&Mfreenet Advanced Cat 6 A Unshielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions
DIAMOND AVIM Connector
DIAMOND AVIM Connector Fiber optic connector for space applications Dr. François CALOZ, accredited laboratory Frédéric TAUGWALDER, Engineering DIAMOND SA - OCT. 2005 - ATELIER CONNECTIQUE - CNES 1 Motivation
4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
Copper Pre-terminated Assemblies
Copper Pre-terminated Assemblies Copper Pre-Terminated Trunk Assemblies Overview Copper Pre-Terminated trunk assemblies are the perfect solution for Enterprise / Premise & Data Centre applications where
Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U
Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U Applications The High Density Cabinets are suitable for Central Offices and can be used as fiber nodes and termination points
DIGITUS Network & Server Cabinets. UNIQUE Series
DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door
Plug & Play Universal Systems
Plug & Play Universal Systems A LANscape Pretium Plug & Play Universal Systems for Data Centers and Storage Area Networks (SANs) Corning Plug & Play universal systems create a fiber optic tip-to-tip solution
What testing is required for PREMISES Fiber Optic Cabling and the standards used
Testing Cabling in the Data Center Part 1 Fiber Testing Wayne Allen Product Marketing Engineer Asia Pacific Region Fluke Networks In this presentation What testing is required for PREMISES Fiber Optic
Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation
Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS
Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow
MERO Floor Systems - CleanRoom
MERO Floor Systems - CleanRoom Innovative solutions out of one hand Development Access floor Consulting Hollow floor Planning Floor covering and Manufacturing Installation Installation Services Floor systems
Excel Pre-terminated Copper and Fibre Optic Systems
Excel Pre-terminated Copper and Fibre Optic Systems Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise.
Fiber-optic cable drums. Mobile. Robust. Individual. Excellence, that connects. Sachsenkabel Cable drums
Fiber-optic cable drums. Mobile. Robust. Individual. Excellence, that connects. Sachsenkabel Cable drums 9 Whether industry, media broadcasting or carriers success is often measured in seconds. The primary
Optical Fibers Fiber Optic Cables Indoor/Outdoor
presents Optical Fibers Fiber Optic Cables Indoor/Outdoor Content Optical fiber function, types optical effects applications production of optical fibre Cable - general types Indoor Indoor / outdoor Outdoor
Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network
Optical Fiber Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network Carl Roberts [email protected] Cabling considerations for DCs and
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
InstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
HARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations
The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations White Paper www.commscope.com Contents Introduction 3 CommScope solution overview 3 InstaPATCH
DATA CENTER SOLUTIONS. MTP cables Patchcords Cat 6A PDU
DATA CENTER SOLUTIONS MTP cables Patchcords Cat 6A PDU 1 DATA CENTER SOLUTIONS Table of contents ORBIS AS A DATA TRANSFER SUPPLIER 3 MECHANICS 4 Server and Network racks 4 PDU power bars 4 Coolers 5 Cold&Hot
Pretium Connector Housings
Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center
Loss & Continuity Testing with MPO/ MTP Connectors
Loss & Continuity Testing with MPO/ MTP Connectors Deployments of fiber optic systems in data centres are now using multimode ribbon fiber and typically MPO/MTP connectors, which have some very particular
Cable management for rack-mounted systems
Cable management for rack-mounted systems technology brief, 2 nd edition Abstract... 2 Introduction... 2 Cable routing guidelines... 3 Separation of power and data cables... 3 Retention of excess cable...
The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.
10 Cables The cables referred to below are provided with standard single- and multimode fibers. Other commercially available fibers can be provided on request. The bare fibers are colored in all cases
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various
7.4 3M No Polish Connector
Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector
LOW LOSS CABLE PAG. 1
LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies
Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method
Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method Jim Hayes, VDV Works, LLC Abstract: We often are asked questions about testing installed fiber optic cables
Optical Power Meter. Specification & User Manual
Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
Secure/Keyed LC System Solutions Overview
Secure/Keyed LC System Solutions Overview Designing performance and efficiency into your secure network Introduction In recent years, physically discrete fiber connection systems have emerged to respond
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
Category 6 UTP - Cabling System
AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS
NEW HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS Features: New! Reduced size and cost versions Reliable high power handling: As much as 80 Watts High Isolation, up to 50dB isolation possible from
Pretium EDGE HD Solutions
Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE HD Solutions create a fiber optic tip-to-tip solution for Data Centers and Storage Area
ADC Structured Cabling Solutions
ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution
Enabling 21 st Century Connectivity
Enabling 21 st Century Connectivity First MXC Adopters meeting March 11, 2014 MXC is a trademark of US Conec Presenters Victor Krutul Director Marketing, Intel Corp Mike Hughes Director, Product Management,
Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009
Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables Steve Swanson May 5, 2009 Current text in 86.10.1 Insertion loss measurements of installed fiber cables are made
GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.
GOWN Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOWN102
Reliable, Consistent, Quality
Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design
Network Monitoring - Fibre TAP Modules
Network Monitoring - Fibre TAP Modules It all started with. Bend insensitive MM fibre Smaller diameter cables Cable with tighter bend radius Less space in the DC, More organised cable management Greater
FullAXS CONNECTOR SEALING & CABLE ASSEMBLY
FullAXS CONNECTOR SEALING & CABLE ASSEMBLY System Solution Guide Next Generation x-tta Solution Next generation WiMAX and Long Term Evolution (LTE) Fiber/Power/Signal To The Antenna (x-tta) connectivity
Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable
Fiber Optic Cable Assemblies Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable 1 Cable assemblies used in patch panels (Fiber Distribution Units) are an essential interface
Auxiliary equipment for communication with the EuroProt protective devices
Auxiliary equipment for communication with the EuroProt protective devices RS232 cable This cable is used to connect the RS232 connector located on the front panel of the EuroProt devices to the 9 pin
19 DYNAmax Free Standing Server C A B I N E T s
9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect Introduction The primary
Items Supplied. Frequency. Designation Description / Delivery Unit Order Number
Fiber Optic Cleaver D6 For Single- and Multimode Fibers Diamond blade for highest cleave quality and long life (typically > 10,000 cleaves) Fiber cleave length: 3.5 to 15 mm Fiber diameter: 125 µm nominal
Site Solutions Next Generation Site Solutions for All Architectures
Site Solutions Next Generation Site Solutions for All Architectures Intro Rosenberger Group Rosenberger is one of the worldwide leading suppliers of controlled impedance and optical connectivity solutions,
Solar Mounting System
Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,
How To Make A Data Center More Efficient
Data Center: Technology Drivers Infrastructure Trends 40G / 100G Migration Maurice F. Zetena III Vice President Leviton Technology Data Center Group Leviton Network Solutions Technology Drivers Convergence
Data Centre & Enterprise Solutions. RapidNet
H E L L E R M A N N T Y T O N Data Centre & Enterprise Solutions RapidNet data centre & Enterprise solutions HellermannTyton is a leading global manufacturer of network cabling solutions which connect,
IN LEITERPLATTEN INTEGRIERTE OPTISCHE VERBINDUNGSTECHNIK AUF DÜNNGLASBASIS
IN LEITERPLATTEN INTEGRIERTE OPTISCHE VERBINDUNGSTECHNIK AUF DÜNNGLASBASIS Dr. Henning Schröder [email protected], phone: +49 30 46403 277 Outlook n Motivation n Manufacturing n Waveguide
Fibre optic testing best practices
Fibre optic testing best practices Adrian Young Senior Technical Support Engineer Fluke Networks November 2011 Singapore Inspecting and cleaning Keeping the output port on your test equipment clean is
Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices
Optical Fiber Data Center Field Testing ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Abstract Data Centers are a growing segment of the enterprise market. Regardless of whether
How To Properly Maintain A Fiber Optic Infrastructure
How To Properly Maintain A Fiber Optic Infrastructure Best Practices to Minimize Damage and Failures in Fiber Optic Infrastructures White Paper Rodney Casteel, RCDD, NTS, OSP, Technical Manager, CommScope
Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug
Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer
Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer [email protected] Outline Data Center Market Drivers Data Center Trends Optical Fiber and Related Standards Optical Fiber
Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1
Knürr DCM 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM conquers the world Standardization in the data center begins with the Knürr DCM! The Knürr DCM is the modular building block
Discontinued. Volition. Fiber Optic Cable. 3Innovation
Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125
ZMR 80 STEREO MODULAR ZONER USERS MANUAL
ZMR 80 STEREO MODULAR ZONER USERS MANUAL Lime Technologies http://limetechnologies.co.uk Tel: 08712 233127 ZMR80 Stereo Modular Zoner Mixer Introduction The modular construction of the ZMR80 allows it
SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS
Features: SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS Low insertion loss < 0.2 db Excellent repeatability FC/PC, SC, ST, LC, MU, E2000 termination available Custom ferrule termination available Designed
PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS
PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS Bandwidth Requirements Push Fiber Optic Solutions Offices, Operations
Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to 1.22 1.11
Knürr Miracel 19 Network and Server Rack Platform 1.12 to 1.22 1.11 19" Server Rack: Knürr Miracel Strong points 1.13 Knürr Miracel ASP ASP/Server Rack 1.16 Knürr Miracel Server Rack 1.18 Knürr Miracel
Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters
Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of
Fiber in the Data Center
Fiber in the Data Center A NetClear White Paper Rudy Montgelas Senior Fiber Product Manager Ortronics/Legrand Lisa Huff Data Center Applications Engineer Berk-Tek, A Nexans Company March 2008 A New Generation
MapIT G2 Infrastructure Management
MapIT G2 Infrastructure Management Introducing MapIT G2, a complete upgrade of Siemon s popular MapIT intelligent infrastructure management (IIM) solution. MapIT G2 integrates a powerful combination of
Times Microwave Systems Hermetically Sealed Assemblies
SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product
Obsolete Fiber Technology? Not in my Data Center!
Obsolete Fiber Technology? Not in my Data Center! White Paper October 2011 Author: James Young Technical Director, Asia Pacific www.commscope.com Do you remember when people used to say fiber optics are
AMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
HSD High Speed Data interconnection
HSD High Speed Data interconnection Fast, safe and robust Very high data bit rate up to 5 Gbit/s SSR smart strain relief enables unstressed solder joints Excellent resistance against cross-talk and RF-EMC
DATA CENTRES POWERED BY EXCEL
DATA CENTRES POWERED BY EXCEL MAXIMISE EFFICIENCY BOOST PERFORMANCE INCREASE R.O.I. WITHOUT COMPROMISE Excel is a world-class premium performance end-to-end infrastructure solution. Designed, manufactured,
LwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility