1 hot products guide gocsc.com

2 Hardware & Adapter Panels who is CSC? Founded in 1972, Communications Supply Corporation (CSC), a subsidiary of WESCO International, Inc. (NYSE: WCC) distributes a full range of IP infrastructure and security products and solutions. Together, CSC and WESCO form the largest electrical and data communications network in North PRODUCT America, FAMILY with 380 full-service branches, a full suite of global distribution capabilities, and annual sales of over $6 billion. With vast resources at their fingertips, the CSC sales team does more than just provide product. Our tenured sales force has a passionate commitment to understanding your unique business needs and will strive every day to get you the best products, the most robust technical expertise, and the most cost-effective logistics solutions available in the data communications distribution business. why CSC? it's simple. our people, passion, and expertise. That s why customers choose CSC. They know our team will do whatever it takes to make them successful each and every day. They value the passion we put into everything we do, and realize when their jobs are on the line we ll be there with the answers they need. They view us as their trusted advisor, who can help them make the transition from legacy infrastructure technologies to state-of-the-art IP solutions. It s really that simple. More and more companies turn to CSC because of our people, passion, and expertise. services CSC s distribution services help customers increase productivity and reduce costs by identifying and deploying services based on their specific project requirements. CSC offers an extensive range of services to fit your needs, including: 24/7 Customer Service and Support Technology Training and Education ebusiness Solutions Custom and Consolidated Reporting Rapid Return Program Job Trailers Expedited Product Sourcing Energy and Power Audits Feed-the-Job Delivery Recycling Services Project Staging Integrated Supply Kitting and Labeling Real-Time National Network Strategic Sourcing and Supplier Selection Cut-to-Length Cabling Services Flexible Financing solutions CSC distributes a wide range of products to support commercial, residential, and government customer applications, including: Network Cabling and Connectivity Network Cabinets and Racks Data Center Products and Solutions Networking Electronics and Wireless Low-Voltage Cabling Security Solutions Sound and Paging Video Surveillance Notification Professional Audio/Visual Access Control Power, Cooling and Monitoring Power over Ethernet Test Equipment Outside Plant Solutions Smart Grid Solutions FTTx (fiber to the home or business) people, passion, AND expertise.

3 hot products guide Tyco Electronics AMP NETCONNECT overview The AMP NETCONNECT business unit of Tyco Electronics, develops, manufactures, and supplies a comprehensive range of communications infrastructure systems and products for customer-owned networks in most every industry. As a leading provider of commercial premises structured cabling systems for optical fiber and twisted-pair copper technologies, Tyco Electronics has broadened its AMP NETCONNECT product portfolio to include a complete line of infrastructure management, data center, 10 Gigabit, secure network and asset management solutions. about Tyco Electronics Tyco Electronics Ltd. is a leading global provider of engineered electronic components, network solutions, specialty products and undersea telecommunication systems, with fiscal 2009 sales of US$10.3 billion to customers in more than 150 countries. Tyco Electronics designs, manufactures and markets products for customers in a broad array of industries including: Automotive Data Communication Systems Consumer Electronics Telecommunications Aerospace, Defense and Marine Medical Energy Lighting With approximately 7,000 engineers and worldwide manufacturing, sales and customer service capabilities, Tyco Electronics' commitment is our customers' advantage. table of contents Copper Cable page(s) Shielded Category 6A & 5e 4-Pair F/UTP Unshielded Category 6 Enhanced 4-Pair UTP Unshielded Category 6 4-Pair UTP Unshielded Category 5e 4-Pair UTP Copper Connectivity Modular Jacks & Inserts Modular Furniture Faceplates Faceplates Communication Outlets Modular Patch Panels & Accessories Modular Patch Cords Modular Plugs Style Termination Blocks & Accessories Copper Modular Pre-Terminated Solutions Pre-Terminated Trunking Cables Fiber Optic Cable Tight Buffered, Indoor Loose Tube, Indoor/Outdoor Fiber Optic Connectivity Modular Jacks & Inserts Distribution Panels/Enclosures Fiber Optic Patch Cords Connectors & Couplers Secure Fiber Connectors Fiber Modular Pre-Terminated Systems MPO and MPO SECURE Cassettes & Cable Assemblies Cable Management FOR MORE INFORMATION CALL TOLL FREE OR VISIT 1

4 Copper Cable SHIELDED CATEGORY 6A & 5e 4-PAIR F/UTP Riser & Plenum F/UTP The perfect cable (Cat6A) for 10GBase-T applications on 100m channels Meets or exceeds TIA/EIA-568-B specifications Independently verified by ETL/SEMKO Exceeds all requirements for Gigabit Ethernet Solid conductors For the complete 10Gig Shielded Solution, see pages 4 & 9 for the Tyco AMP Netconnect Shielded Jack and Patch Panels Riser, Shielded, Category 6A, F/UTP, 23 AWG, White Riser, Shielded, Category 6A, F/UTP, 23 AWG, Grey Riser, Shielded, Category 6A, F/UTP, 23 AWG, Blue Riser, Shielded, Category 6A, F/UTP, 23 AWG, Yellow Riser, Shielded, Category 5e, FTP, 24 AWG, Grey Riser, Shielded, Category 5e, FTP, 24 AWG, Blue NOTE: Others colors are available; contact your local CSC Representative Plenum, Shielded, Category 6A, FTP, 23 AWG, White Plenum, Shielded, Category 6A, FTP, 23 AWG, Grey Plenum, Shielded, Category 6A, FTP, 23 AWG, Blue Plenum, Shielded, Category 6A, FTP, 23 AWG, Yellow Plenum, Shielded, Category 5e, FTP, 24 AWG, White Plenum, Shielded, Category 5e, FTP, 24 AWG, Grey Plenum, Shielded, Category 5e, FTP, 24 AWG, Blue UNSHIELDED CATEGORY 6 ENHANCED 4-PAIR UTP Riser & Plenum Exceeds cable specifications for Category 6 with superior NEXT, return loss, and delay skew Performance characterized to 600 MHz Independently verified by ETL/SEMKO Exceeds all requirements for Gigabit Ethernet Lead-free jacketing Category 6E, Riser, 4-Pair/23 AWG, White, RB* Category 6E, Riser, 4-Pair/23 AWG, Grey, RB* Category 6E, Riser, 4-Pair/23 AWG, Blue, RB* Category 6E, Riser, 4-Pair/23 AWG, Yellow, RB* Category 6E, Riser, 4-Pair/23 AWG, White, WR* Category 6E, Riser, 4-Pair/23 AWG, Grey, WR* Category 6E, Riser, 4-Pair/23 AWG, Blue, WR* Category 6E, Riser, 4-Pair/23 AWG, Yellow, WR* * RB = Reel-in-a-Box, WR = Reel Category 6E, Plenum, 4-Pair/23 AWG, White, RB* Category 6E, Plenum, 4-Pair/23 AWG, Grey, RB* Category 6E, Plenum, 4-Pair/23 AWG, Blue, RB* Category 6E, Plenum, 4-Pair/23 AWG, Yellow, RB* Category 6E, Plenum, 4-Pair/23 AWG, White, WR* Category 6E, Plenum, 4-Pair/23 AWG, Grey, WR* Category 6E, Plenum, 4-Pair/23 AWG, Blue, WR* Category 6E, Plenum, 4-Pair/23 AWG, Yellow, WR* UNSHIELDED CATEGORY 6 4-PAIR UTP Riser & Plenum Exceeds cable specifications for Category 6 Performance characterized to 600 MHz ETL/SEMKO listed (CMR/CMP) Independently verified by ETL/SEMKO Lead-free jacketing Category 6, Riser, 4-Pair/23 AWG, White, RB* Category 6, Riser, 4-Pair/23 AWG, Grey, RB* Category 6, Riser, 4-Pair/23 AWG, Blue, RB* Category 6, Riser, 4-Pair/23 AWG, Yellow, RB* Category 6, Riser, 4-Pair/23 AWG, White, WR* Category 6, Riser, 4-Pair/23 AWG, Grey, WR* Category 6, Riser, 4-Pair/23 AWG, Blue, WR* Category 6, Riser, 4-Pair/23 AWG, Yellow, WR* Category 6, Plenum, 4-Pair/23 AWG, White, RB* Category 6, Plenum, 4-Pair/23 AWG, Grey, RB* Category 6, Plenum, 4-Pair/23 AWG, Blue, RB* Category 6, Plenum, 4-Pair/23 AWG, Yellow, RB* Category 6, Plenum, 4-Pair/23 AWG, White, WR* Category 6, Plenum, 4-Pair/23 AWG, Grey, WR* Category 6, Plenum, 4-Pair/23 AWG, Blue, WR* Category 6, Plenum, 4-Pair/23 AWG, Yellow, WR* * RB = Reel-in-a-Box, WR = Reel 2 FOR MORE INFORMATION CALL TOLL FREE OR VISIT

5 Copper Cable UNSHIELDED CATEGORY 5e 4-PAIR UTP Riser & Plenum Exceeds TIA/EIA and ISO Category 5e (Enhanced Category 5) specifications Independently verified by ETL/SEMKO Performance characterized to 350 MHz UL and cul Listed (CMR/CMP) Lead-free jacketing Category 5e, Riser, 4-Pair/24 AWG, White, RB* Category 5e, Riser, 4-Pair/24 AWG, Grey, RB* Category 5e, Riser, 4-Pair/24 AWG, Blue, RB* Category 5e, Riser, 4-Pair/24 AWG, Yellow, RB* Category 5e, Riser, 4-Pair/24 AWG, White, WR* Category 5e, Riser, 4-Pair/24 AWG, Grey, WR* Category 5e, Riser, 4-Pair/24 AWG, Blue, WR* Category 5e, Riser, 4-Pair/24 AWG, Yellow, WR* Category 5e, Riser, 4-Pair/24 AWG, White, PB* Category 5e, Riser, 4-Pair/24 AWG, Grey, PB* Category 5e, Riser, 4-Pair/24 AWG, Blue, PB* Category 5e, Riser, 4-Pair/24 AWG, Yellow, PB* Category 5e, Plenum, 4-Pair/24 AWG, White, RB* Category 5e, Plenum, 4-Pair/24 AWG, Grey, RB* Category 5e, Plenum, 4-Pair/24 AWG, Blue, RB* Category 5e, Plenum, 4-Pair/24 AWG, Yellow, RB* Category 5e, Plenum, 4-Pair/24 AWG, White, WR* Category 5e, Plenum, 4-Pair/24 AWG, Grey, WR* Category 5e, Plenum, 4-Pair/24 AWG, Blue, WR* Category 5e, Plenum, 4-Pair/24 AWG, Yellow, WR* Category 5e, Plenum, 4-Pair/24 AWG, White, PB* Category 5e, Plenum, 4-Pair/24 AWG, Grey, PB* Category 5e, Plenum, 4-Pair/24 AWG, Blue, PB* Category 5e, Plenum, 4-Pair/24 AWG, Yellow, PB* * RB = Reel-in-a-Box, WR = Reel, PB = Pull Box UNSHIELDED CATEGORY 5e 4-PAIR UTP Riser & Plenum Exceeds TIA/EIA and ISO Category 5e (Enhanced Category 5) specifications Independently verified by ETL/SEMKO Performance characterized to 200 MHz UL and cul Listed (CMR/CMP) Lead-free jacketing Category 5e, Riser, 4-Pair/24 AWG, White, RB* Category 5e, Riser, 4-Pair/24 AWG, Grey, RB* Category 5e, Riser, 4-Pair/24 AWG, Blue, RB* Category 5e, Riser, 4-Pair/24 AWG, Yellow, RB* Category 5e, Riser, 4-Pair/24 AWG, White, WR* Category 5e, Riser, 4-Pair/24 AWG, Grey, WR* Category 5e, Riser, 4-Pair/24 AWG, Blue, WR* Category 5e, Riser, 4-Pair/24 AWG, Yellow, WR* Category 5e, Riser, 4-Pair/24 AWG, White, PB* Category 5e, Riser, 4-Pair/24 AWG, Grey, PB* Category 5e, Riser, 4-Pair/24 AWG, Blue, PB* Category 5e, Riser, 4-Pair/24 AWG, Yellow, PB* * RB = Reel-in-a-Box, WR = Reel, PB = Pull Box Category 5e, Plenum, 4-Pair/24 AWG, White, RB* Category 5e, Plenum, 4-Pair/24 AWG, Grey, RB* Category 5e, Plenum, 4-Pair/24 AWG, Blue, RB* Category 5e, Plenum, 4-Pair/24 AWG, Yellow, RB* Category 5e, Plenum, 4-Pair/24 AWG, White, WR* Category 5e, Plenum, 4-Pair/24 AWG, Grey, WR* Category 5e, Plenum, 4-Pair/24 AWG, Blue, WR* Category 5e, Plenum, 4-Pair/24 AWG, Yellow, WR* Category 5e, Plenum, 4-Pair/24 AWG, White, PB* Category 5e, Plenum, 4-Pair/24 AWG, Grey, PB* Category 5e, Plenum, 4-Pair/24 AWG, Blue, PB* Category 5e, Plenum, 4-Pair/24 AWG, Yellow, PB* FOR MORE INFORMATION CALL TOLL FREE OR VISIT 3

6 Copper Connectivity MODULAR JACKS & INSERTS XG Category 6A AMP-TWIST Shielded Modular Jacks 10GBASE-T The perfect jack for Category 6A 10GBase-T applications on 100m channels Easy installation with only two parts, reusable Terminates in under one minute with SL Tool, shown below Universally labeled lacing fixture permits T568A or T568B wiring UL Listed, meets all TIA and ISO requirements Rear Entry, with Dust Cover Rear Entry, without Dust Cover Side Entry, with Dust Cover Side Entry, without Dust Cover AMP NETCONNECT SL Series SL Series 110Connect Shielded Jacks Thin profile improves output density Universal label permits T568A or B wiring Terminates with SL Tool, shown below, or standard punch-down tools UL Listed, meets all TIA and ISO requirements Shielded jacks not available in colors Cat 6, Rear Entry Cat 6, Side Entry Cat 5e, Rear Entry Cat 5e, Side Entry ToolLess, Cat 5e, Rear Entry SL Series 110Connect Unshielded Jacks SL Series provides high density and front loadable connectivity 110-Style termination A wide array of strain reliefs and inserts available Fits standard faceplates and SL Series modules/faceplates Cat 6 Jack, Universal Wiring, Almond Cat 6 Jack, Universal Wiring, Blue Cat 6 Jack with Dust Cover, Universal Wiring, Almond Cat 6 Jack with Dust Cover, Universal Wiring, Blue Cat 5E Jack, Universal Wiring, Almond Cat 5E Jack, Universal Wiring, Blue Cat 5E Jack with Dust Cover, Universal Wiring, Almond Cat 5E Jack with Dust Cover, Universal Wiring, Blue Cat 3 Jack, RJ11C/RJ14C/RJ25C Wiring, Almond Cat 3 Jack, RJ11C/RJ14C/RJ25C Wiring, Blue Cat 3 Jack with Dust Cover, RJ11C/RJ14C/RJ25C Wiring, Almond Cat 3 Jack with Dust Cover, RJ11C/RJ14C/RJ25C Wiring, Blue SL Series Strain Reliefs For use with SL Series 110Connect modular jacks Cat 6 Strain Relief, Bend Limiting Cat 5E Strain Relief, Bend Limiting Cat 6, Cat 5E, Cat 3 Strain Relief NOTE: For additional color options, replace suffix with -1 = Almond, -2 = Black, -3 = White, -4 = Grey; additional prefix required for: = Electrical Ivory (i.e ). 4 FOR MORE INFORMATION CALL TOLL FREE OR VISIT

7 Copper Connectivity MODULAR JACKS & INSERTS AMP NETCONNECT SL Series SL Series Toolless Unshielded Jacks SL Series provides high density and front-loadable connectivity Toolless termination A wide array of strain reliefs and inserts available Fits standard faceplates and SL Series modules/faceplates Cat 5E Jack, Universal Wiring, Almond Cat 5E Jack, Universal Wiring, Blue Cat 5E Jack with Dust Cover, Universal Wiring, Almond Cat 5E Jack with Dust Cover, Universal Wiring, Blue Cat 3 Jack, RJ11C/RJ14C/ RJ25C Wiring, Almond NOTE: For other color options, replace suffix with -2 = Black, -3 = White, -4 = Grey, -5 = Orange, -6 = Blue, -7 = Red, -8 = Yellow, -9 = Green; additional prefix required for: = Violet, = Electrical Ivory (i.e ) Cat 3 Jack, RJ11C/RJ14C/ RJ25C Wiring, Blue Cat 3 Jack with Dust Cover, RJ11C/RJ14C/ RJ25C Wiring, Almond Cat 3 Jack with Dust Cover, RJ11C/RJ14C/ RJ25C Wiring, Blue 110Connect Jacks & Inserts 110Connect Jacks Category 5e, T568A/B, Universal Wiring, Blue Category 5e, T568A/B, Universal Wiring, Blue Category 3, T568A/B, Universal Wiring, Blue Connect Jack Stuffer Cap, Almond NOTE: For other color options, replace suffix with -1 = Almond, -2 = Black, -3 = White, -4 = Grey, -5 = Orange, -6 = Blue, -7 = Red, -8 = Yellow, -9 = Green; additional prefix required for: = Violet, = Electrical Ivory (i.e ). SL Series 110Connect Jack Termination Tool Termination tool for AMP-TWIST and SL Series 110Connect modular jacks Terminates and cuts all eight conductors at once Dramatically speeds terminations Lacing fixture is for use with SL Series 110Connect modular jacks and is included with SL Tool is available without lacing fixture for AMP-TWIST-only installs SL Series 110 Termination Tool SL Series 110 Termination Tool, Less Lacing Fixture SL Tool, Lacing Fixture Only FOR MORE INFORMATION CALL TOLL FREE OR VISIT 5

8 Copper Connectivity MODULAR JACKS & INSERTS AMP NETCONNECT SL Series SL Series Inserts Blank Insert, Almond Blank Insert, White BNC Connector, Almond BNC Connector, White F Connector, Almond F Connector, White Red Dielectric, RCA/110 Insert, Almond Red Dielectric, RCA/110 Insert, White White Dielectric, RCA/110 Insert, Almond White Dielectric, RCA/110 Insert, White Yellow Dielectric, RCA/110 Insert, Almond Yellow Dielectric, RCA/110 Insert, White S-Video, 110 Termination, Almond S-Video, 110 Termination, White mm Headphone Jack, Almond mm Headphone Jack, White Speaker Post, Black Stripe, Almond Speaker Post, Black Stripe, White Speaker Post, Red Stripe, Almond Speaker Post, Red Stripe, White Binding Post, Black, Almond Binding Post, Black, White Binding Post, Red, Almond Binding Post, Red, White MODULAR FURNITURE FACEPLATES FLEX-MODE Faceplates for Modular Furniture Fits most modular furniture raceways Accepts jacks and multimedia inserts Icons for port identification Port, Black Port, Almond Port, Black Port, Almond Port, T568A* Cat 5, Black Port, T568A* Cat 5, Almond Port, T568B* Cat 5, Black Port, T568B* Cat 5, Almond *Includes Category 5 modular jack printed circuit board assembly. NOTE: Also available in Grey; replace suffix with FOR MORE INFORMATION CALL TOLL FREE OR VISIT

9 Copper Connectivity FACEPLATES AMP NETCONNECT SL Series Modules/Faceplates SL Series Modules (Accepts SL Series Jacks/Inserts) Front loading Patented invisible icons stay hidden until used Fits SL Series Jacks and Faceplates Port Straight, 1-Unit, Almond Port Straight, 1-Unit, White Port Angled, 1.5-Unit, Almond Port Angled, 1.5-Unit, White Port Angled, 1.5-Unit, Almond Port Angled, 1.5-Unit, White Port Straight, SC to SC, 1-Unit, Almond Port Straight, SC to SC, 1-Unit, White Port Straight, SC to ST, 1-Unit, Almond Port Straight, SC to ST, 1-Unit, White Blank Module, 1-Unit, Almond Blank Module, 1-Unit, White Blank Module, 1.5-Unit, Almond Blank Module, 1.5-Unit, White SVGA/110 Module, Almond SVGA/110 Module, White SL Series Faceplates (accepts SL Series Modules) Single-Gang, Accepts 3 x 1-Unit or 2 x 1.5-Unit Modules, Almond Single-Gang, Accepts 3 x 1-Unit or 2 x 1.5-Unit Modules, White Double-Gang, Accepts 3 x 1-Unit or 2 x 1.5-Unit Modules, Almond, Double-Gang, Accepts 3 x 1-Unit or 2 x 1.5-Unit Modules, White Double-Gang, Accepts 3 x 1-Unit or 2 x 1.5-Unit Modules Each Side, Almond Double-Gang, Accepts 3 x 1-Unit or 2 x 1.5-Unit Modules Each Side, White Port Mounting Strap for Electrical Faceplate, Almond Port Mounting Strap for Electrical Faceplate, White NOTE: For additional color options, replace suffix with -1 = Almond, -2 = Black, -3 = White, -4 = Grey; additional prefix required for: = Electrical Ivory (i.e ). Faceplates Standard, Iconable, 2-Port, Single-Gang, Almond Standard, Iconable, 2-Port, Single-Gang, White Standard, Iconable, 4-Port, Angled, Single-Gang, Almond Standard, Iconable, 4-Port, Angled, Single-Gang, White Standard, Iconable, 4-Port, Staggered*, Single-Gang, Almond Standard, Iconable, 4-Port, Staggered*, Single-Gang, White Standard, Iconable, 4-Port, Single-Gang, Almond Standard, Iconable, 4-Port, Single-Gang, White Standard, Iconable, 6-Port, Single-Gang, Almond Standard, Iconable, 6-Port, Single-Gang, White Standard, Iconable, 4-Port, Double-Gang, Almond Standard, Iconable, 4-Port, Double-Gang, White Standard, Iconable, 6-Port, Double-Gang, Almond Standard, Iconable, 6-Port, Double-Gang, White Standard, Iconable, 12-Port, Double-Gang, Almond Standard, Iconable, 12-Port, Double-Gang, White Flush, Non-Iconable, 2-Port, Single-Gang, Almond Flush, Non-Iconable, 2-Port, Single-Gang, White Flush, Non-Iconable, 4-Port, Single-Gang, Almond Flush, Non-Iconable, 4-Port, Single-Gang, White Flush, Non-Iconable, Almond, 6-Port, Single-Gang, Flush, Non-Iconable, 6-Port, Single-Gang, White Port Duplex Mounting Strap, Almond Port Duplex Mounting Strap, White NOTE: For other color options, replace suffix with -1 = Almond, -2 = Black, -3 = White, -4 = Grey; additional prefix required for: = Electrical Ivory (i.e ). *Staggered port arrangement. FOR MORE INFORMATION CALL TOLL FREE OR VISIT 7

10 Copper Connectivity COMMUNICATION OUTLETS AMP Communication Outlets (ACO) Installation Kits ACO Inserts Category 6 and 5e inserts are UL verified to comply with all requirements of TIA/EIA-568-A. Dual inserts enable the combination of two applications on one 4-pair cable Single Insert Unshielded, Cat 5e, T568A Wiring Pattern, Almond Single Insert Unshielded, Cat 5e, T568A Wiring Pattern, White Single Insert Unshielded, Cat 5e, T568B Wiring Pattern, Almond Single Insert Unshielded, Cat 5e, T568B Wiring Pattern, White Single Insert Unshielded, Cat 6, T568A, Almond Single Insert Unshielded, Cat 6, T568A, White Single Insert Unshielded, Cat 6, T568B, Almond Single Insert Unshielded, Cat 6, T568B, White Dual Insert Unshielded, Cat 5e, Dual Token Ring Wiring Pattern, Almond Dual Insert Unshielded, Cat 5e, Dual Token Ring Wiring Pattern, White Dual Insert Unshielded, Cat 5e, Dual 10/100Base-T Wiring Pattern, Almond Dual Insert Unshielded, Cat 5e, Dual 10/100Base-T Wiring Pattern, White Dual Insert Unshielded, Cat 5e, Token Ring & 10/100Base-T Wiring Pattern, Almond Dual Insert Unshielded, Cat 5e, Token Ring & 10/100Base-T Wiring Pattern, White Dual Insert Unshielded, Cat 5e, Dual ATM/TP-PMD Wiring Pattern, Almond Dual Insert Unshielded, Cat 5e, Dual ATM/TP-PMD Wiring Pattern, White Blank Insert Cover, Almond Blank Insert Cover, White NOTE: For other color options, replace suffix with -3 = Black, -4 = Grey, -6 = Electrical Ivory. Blank insert not available in -6 = Electrical Ivory, but available in -9 = White. Shielded products also available; contact your local CSC Representative. 110Connect punch down or AMP-BARREL terminations Installation kits with 110Connect edge connectors are pre-loaded for faster termination Installation kits are provided with stuffer caps Dual-Port Installation Kit (unshielded) for 110 Connect Edge Connectors Dual-Port Low-Profile Installation Kit (unshielded) for 110 Connect Edge Connectors Dual-Port Installation Kit (unshielded) for Barrel Edge Connectors Faceplates Offered in five colors Icons and/or labels for easy identification Single-Gang, Iconable, Almond Single-Gang, Iconable, White Single-Gang, Low Profile, Almond Single-Gang, Low Profile, White Single-Gang, Almond Single- and double-gang offerings Durable ABS plastic construction Single-Gang, White Double-Gang, Iconable, Almond Double-Gang, Iconable, White Double-Gang, Almond Double-Gang, White NOTE: For other color options, replace suffix with -3 = Black, -4 = NEMA Grey, 6 = Electrical Ivory. Surface Mount Boxes Single-gang box has cable/raceway entry on top and bottom Double-gang box has cable/raceway entry on all four sides Additional cable entry in rear on both boxes Single-Gang, Almond Single-Gang, White Double-Gang, Almond Double-Gang, White NOTE: For other color options, replace suffix with -2 = Black, -4 = Grey, -5 = Electrical Ivory. 8 FOR MORE INFORMATION CALL TOLL FREE OR VISIT

11 Copper Connectivity MODULAR PATCH PANELS & ACCESSORIES AMP NETCONNECT Shielded Patch Panels Port Multimedia Panel Standard, No Jacks* Port Multimedia Panel Angled, No Jacks* Port Multimedia Panel Standard, No Jacks* Port Multimedia Panel Angled, No Jacks* Port XG Category 6A Shielded AMP TWIST Panel Standard, Jacks Included Port XG Category 6A Shielded AMP TWIST Panel Angled, Jack Included Port XG Category 6A Shielded AMP TWIST Panel Standard, Jacks Included Port XG Category 6A Shielded AMP TWIST Panel Angled, Jacks Included * For Shielded Jacks see page 4. SL Series Unshielded Patch Panels Category 6 12 Ports, Universal Wiring, Category 6 24 Ports, Universal Wiring, 1 RMS* Category 6 24 Ports, Angled, Universal Wiring, 1 RMS* Category 6 24 Ports, Hinged, Universal Wiring, 1 RMS* Category 6 48 Ports, Universal Wiring, 2 RMS* Category 6 48 Ports, Angled, Universal Wiring, 2 RMS* Category 6 48 Ports, Hinged, Universal Wiring, 2 RMS* 110Connect Enhanced Category 5e Ports, Universal Wiring, Ports, Universal Wiring, 1 RMS* Ports, Universal Wiring, 1 RMS* Ports, Universal Wiring, 2 RMS* Ports, Universal Wiring, 4 RMS* 12-Port panel includes an 89D bracket for wall mounting. NOTE: Also available in angled and hinged models. *RMS = 1.75" Category 6 96 Ports, Universal Wiring, 4 RMS* Category 5E 12 Ports, Universal Wiring, Category 5E 24 Ports, Universal Wiring, 1 RMS* Category 5E 24 Ports, Angled, Universal Wiring, 1 RMS* Category 5E 48 Ports, Universal Wiring, 2 RMS* Category 5E 48 Ports, Angled, Universal Wiring, 2 RMS* Category 5E 96 Ports, Universal Wiring, 4 RMS* * RMS = 1.75", -2 = Unloaded, jacks bagged. 12-Port panel includes an 89D bracket for wall mounting. -2 ONLY for now on, NO -1 available. FOR MORE INFORMATION CALL TOLL FREE OR VISIT 9

12 Copper Connectivity MODULAR PATCH CORDS AMP NETCONNECT Shielded Category 6, Booted ', Grey ', Blue ', White ', Grey ', Blue ', White Unshielded Category 6, Booted ', Black ', Blue ', White ', Black ', Blue ', White ', Black ', Blue Unshielded Enhanced Category 5, Booted ', Black ', Blue ', White ', Black ', Blue ', White ', Black ', Blue Unshielded Enhanced Category 5, Bootless ', Grey ', Blue ', White ', Grey ', Blue ', White Slim plug and boot design provides additional space between adjacent plugs ', White ', Black ', Blue ', White ', Black ', Blue ', White ', White ', Black ', Blue ', White ', Black ', Blue ', White ', Black ', Blue ', White ', Black ', Blue ', White ', Black ', Blue ', White ', Black ', Blue ', White ', Black ', Blue ', White NOTE: Patch cords available in Black, Grey, Blue, Green, Red, White, Yellow, Orange, and Violet colors. Contact your local CSC Representative. Patch cords available in 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 15, 16, 20, 25, 30, 40, and 50' lengths. Contact your local CSC Representative. 10 FOR MORE INFORMATION CALL TOLL FREE OR VISIT

13 Copper Connectivity MODULAR PLUGS High-Performance Modular Plugs for Category 6 Applications Position, Unshielded, Stranded, 100 per Package Position, Unshielded, Solid, 100 per Package NOTE: These plugs are designed to accommodate 24 AWG stranded conductors with a maximum conductor insulation diameter of 0.043" and cable jacket outside diameters in the range of ". High-Performance Modular Plugs for Category 5E, Category 5 Applications These High-Performance Modular Plugs exceed TIA/EIA-568A and TSB-40A requirements for 4-pair (RJ45) unshielded twisted pair applications. Cable assembly manufacturing using this high-performance plug has been made easier through the use of AMP load bar, which provides a means of maintaining the 1 2" untwist requirement Position, Unshielded, Stranded, 100 per Package Position, Unshielded, Solid, 100 per Package Position, Shielded, Stranded, 100 per Package Position, Shielded, Solid, 100 per Package NOTE: These plugs are designed to accommodate 24 AWG stranded conductors with a maximum conductor insulation diameter of 0.039" and cable jacket outside diameters in the range of ". Plugs for Category 3 Applications Modular Plug Crimp Tools and Dies 8 Position Round Cable Plugs, AWG Stranded Wire, 8 Positions/8 Contacts Modular Plugs, AWG Solid Wire, 6 Positions/6 Contacts Modular Plugs, AWG Solid Wire, 8 Positions/8 Contacts Also available. For ordering information, contact your local CSC Representative. FOR MORE INFORMATION CALL TOLL FREE OR VISIT 11

14 Copper Connectivity 110 STYLE TERMINATION BLOCKS & ACCESSORIES AMP NETCONNECT 110 Hardware Wiring Blocks 610XC wiring blocks accept AWG conductors. Blocks are available in 50-, 100-, and 300-pair sizes with legs for backboard mounting. Wiring blocks without legs in 50- and 100-pair sizes are also available Category 5E, 50-Pair with Legs Category 5E, 100-Pair with Legs Category 5E, 300-Pair with Legs Category 5E, 50-Pair without Legs Category 5E, 100-Pair without Legs Connecting Blocks 610XC connecting blocks utilize double-ended insulation displacement contacts (IDC) that terminate AWG solid or stranded conductors with a maximum O.D. of 0.063". The blocks are available in 3-, 4-, and 5-pair sizes with the appropriate color coding. Cross-Connect Kits Includes wiring blocks with legs, connecting blocks, designation strips, and white labels for the pair counts identified Category 5E, 100-Pair; 4-Pair Connecting Blocks Category 5E, 100-Pair; 5-Pair Connecting Blocks Category 5E, 300-Pair; 4-Pair Connecting Blocks Category 5E, 300-Pair; 5-Pair Connecting Blocks Cross-Connect Distribution Frame Kit Kit includes metal back frame, wiring blocks, connecting blocks, cable management troughs, designation strips, and appropriate hardware Category 5E, 300-Pair; 4-Pair Connecting Blocks Category 5E, 300-Pair; 5-Pair Connecting Blocks Category 5E, 900-Pair; 4-Pair Connecting Blocks Category 5E, 900-Pair; 5-Pair Connecting Blocks Category 5E 4-Pair Connecting Blocks Category 5E 5-Pair Connecting Blocks NOTE: 610XC components are not compatible with 110Connect XC components. All 610XC products are color Black. Cable Management Trough Category 5E with Legs, White Category 5E without Legs, White NOTE: 610XC components are not compatible with 110Connect XC components. 110 Labels and Holders Clear NOTE: Other label colors available; contact your local CSC Representative. Change to 110Connect XC Patch Plugs and Cable Assemblies 110Connect XC patch plugs are verified for Category 5e performance Accommodates AWG stranded conductors Field terminability enables customers to create custom patch cables Termination is easy; lace conductors in one half of connector and simply snap two halves together Polarization feature to ensure proper connection Pair Cable Assembly Pair Cable Assembly, , 10' Pair Cable Assembly, 110-Modular (T568A), 10' Pair Cable Assembly, 110-Modular (T568B), 10' NOTE: Also available in 2', 4', 6', and 8' lengths; contact your local CSC Representative. 12 FOR MORE INFORMATION CALL TOLL FREE OR VISIT

15 Copper Modular Pre-Terminated Solutions PRE-TERMINATED TRUNKING CABLES The MRJ21 is a high-performance, high-density, small form factor copper cabling solution for current and future applications, including Gigabit Ethernet, VoIP, and powered Ethernet. The dense CHAMP style MRJ21 connector and cabling reduces cable bulk in pathways and spaces, enabling much higher port counts in a smaller space. The system s modular, pluggable, reusable design significantly reduces installation time. All components are factory terminated and tested, enabling true plug-and-play performance. Many switchgear manufacturers are adopting this interface with additional hardware options coming soon. MRJ21 Cassettes High-density, small form factor connectivity converts one MRJ21 interface to six or twelve RJ45 Modular, pluggable design Factory terminated and tested Port MRJ21 Cassette, 10/100/1000Base-T (4-Pair) Port MRJ21 Cassette, 10/100Base-T (2-Pair) MRJ21 Cassette Panel for 3 MRJ21 Cassettes, 1U MRJ21 Patch Panels High-density, small form factor connectivity Factory terminated and tested Modular, pluggable design AMPTRAC Ready Panels also available Port, 10/100/1000Base-T, 4-Pair, Patch Panel, 1U, Standard Footprint Port, 10/100/1000Base-T, 4-Pair, Patch Panel, 1U, Standard Footprint Port, 10/100Base-T, 2-Pair, Patch Panel, 1U, Standard Footprint Port, 10/100/1000Base-T, 4-Pair, Patch Panel, 1U, Angled Footprint MRJ21 Cable Assemblies Dense CHAMP design connectors with 25-pair, unshielded 24 AWG conductor cable Dense contact layout and footprint reduces cross talk and built-in compensation Offers significantly increased port density over RJ21 and RJ45 interfaces Jackscrews for positive latching and secure cable retention Configuration Table Connector A Connector B Cable Rating Cable Color Base Part No. MRJ21(180 ) MRJ21(180 ) Riser Grey X MRJ21(180 ) MRJ21(180 ) Plenum Blue X MRJ21(180 ) MRJ21(45 ) Riser Grey X Standard Lengths are 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 17, 20, 25, 30, 35, 40, 50, 60, 70, 80, and 90 meters. Example part number for 10 meter MRJ21 to MRJ21 plenum assembly: Custom cable assemblies are available; contact your local CSC Representative. Ordering Information: Because of the large number of options and configurations available, we cannot list all of them in this catalog. For availability and applications assistance, contact your local CSC Representative. FOR MORE INFORMATION CALL TOLL FREE OR VISIT 13

16 Fiber Optic Cable TIGHT BUFFERED, INDOOR Premise Distribution Multimode Cable Suitable for horizontal and in-building backbone cabling Designed for direct termination with LightCrimp, LightCrimp Plus, epoxy/polish, and MT-RJ Jacks TIA color-coded fibers for easy identification UL and cul Listed in both riser and plenum configurations Interlocking armored cables are available Fiber, 62.5/125, MM, Riser Fiber, 62.5/125, MM, Riser Fiber, 62.5/125, MM, Riser Fiber, 50/125, MM, Riser Fiber, 50/125, MM, Riser Fiber, 50/125, MM, Riser Fiber, XG, MM, Riser Fiber, XG, MM, Riser Fiber, XG, MM, Riser Fiber, 62.5/125, MM, Plenum Fiber, 62.5/125, MM, Plenum Fiber, 62.5/125, MM, Plenum Fiber, 50/125, MM, Plenum Fiber, 50/125, MM, Plenum Fiber, 50/125, MM, Plenum Fiber, XG, MM, Plenum Fiber, XG, MM, Plenum Fiber, XG, MM, Plenum LOOSE TUBE, INDOOR/OUTDOOR Indoor/Outdoor Single Loose Tube Multimode Cable Suitable for horizontal and in-building backbone cabling TIA color-coded fibers for easy identification UL and cul Listed in both riser and plenum configurations Water-blocked buffer tube for water penetration protection Can go directly from outdoors into building riser or plenum spaces Fiber, 62.5/125, MM, Riser Fiber, 62.5/125, MM, Riser Fiber, 62.5/125, MM, Riser Fiber, 50/125, MM, Riser Fiber, 50/125, MM, Riser Fiber, 50/125, MM, Riser Fiber, XG, MM, Riser Fiber, XG, MM, Riser Fiber, XG, MM, Riser Fiber, 62.5/125, MM, Plenum Fiber, 62.5/125, MM, Plenum Fiber, 50/125, MM, Plenum Fiber, 50/125, MM, Plenum Fiber, XG, MM, Plenum Fiber, XG, MM, Plenum 14 FOR MORE INFORMATION CALL TOLL FREE OR VISIT

17 Fiber Optic Connectivity MODULAR JACKS & INSERTS AMP NETCONNECT SL Series Fiber Inserts MT-RJ jacks are two fiber, reterminable connectors which eliminate the need for separate couplers MT-RJ outlet jacks include an SL Series housing for mounting in faceplates as well as bend limiting boot, fiber guide and actuation key for termination LC, SC and ST couplers allow fiber connectors of various fiber types to be mounted in AMP NETCONNECT faceplates MT-RJ, Multimode, 50/125 μm, Black, Almond MT-RJ, Multimode, 50/125 μm, Black, Blue MT-RJ, Multimode, 62.5/125 μm, Beige, Almond MT-RJ, Multimode, 62.5/125 μm, Beige, Blue Secure MT-RJ, Multimode 50/125 μm, Almond Secure MT-RJ, Multimode 50/125 μm, Blue Secure MT-RJ Multimode 62.5/125 μm, Almond Secure MT-RJ Multimode 62.5/125 μm, Blue For use in SL Series Modules and Faceplates, see page Multimode ST Connector, Almond Multimode ST Connector, White Multimode LC Duplex Connector, Almond Multimode LC Duplex Connector, White Singlemode ST Connector, Almond Singlemode ST Connector, White Singlemode LC Duplex Connector, Almond Singlemode LC Duplex Connector, White DISTRIBUTION PANELS/ENCLOSURES Rack Mount Enclosures 24- and 48-Port Rack Enclosures Removable back cover for easy installation Cable strain-relief brackets in back Snap-in adapter plates Edge guard on front and rear cable entry Port Capacity, Unloaded, 3.5" (2U) High, Black Port Capacity, Unloaded, 5.25" (3U) High, Black Port Capacity, Unloaded, 7.0" (4U) High, Black NOTE: Uses the same Snap-in Adapter Plates as the AMP Wall Mount boxes (see below) Port Rack Enclosure Wall Mount Enclosure Assemblies Wall Mount Enclosure Assembly 12-Port, Loaded with ST Style MM Bushings, without Side Protective Cover, Black Anodized Wall Mount Enclosure Assembly 12-Port, Loaded with ST Style MM Bushings, with Side Protective Cover, Black Anodized Wall Mount Enclosure Assembly 12-Port Capacity, Unloaded, Black Wall Mount Enclosure Assembly 24-Port Capacity, Unloaded, Black Optional Fiber Snap-In Adapter Plate 6-Fiber, ST-Style, Multimode Optional Fiber Snap-In Adapter Plate 6-Fiber, ST-Style, Singlemode Optional Fiber Snap-In Adapter Plate 6-Fiber, SC Duplex, Multimode Optional Fiber Snap-In Adapter Plate 6-Fiber, SC Duplex, Singlemode Optional Fiber Snap-In Adapter Plate 12-Fiber, MT-RJ (order jacks separately) FOR MORE INFORMATION CALL TOLL FREE OR VISIT 15

18 Fiber Optic Connectivity FIBER OPTIC PATCH CORDS Duplex Fiber Patch Cords (Ceramic Ferrules) Multimode SC/SC, 1m Length Multimode SC/SC, 2m Length Multimode SC/SC, 3m Length Multimode SC/SC, 5m Length Multimode SC/SC, 10m Length Multimode ST/SC, 1m Length Multimode ST/SC, 2m Length Multimode ST/SC, 3m Length Multimode ST/SC, 5m Length Multimode ST/SC, 10m Length Multimode ST/ST, 1m Length Multimode ST/ST, 2m Length Multimode ST/ST, 3m Length Multimode ST/ST, 5m Length Multimode ST/ST, 10m Length Multimode SC/LC, 1m Length Multimode SC/LC, 2m Length Multimode SC/LC, 3m Length Multimode SC/LC, 5m Length Multimode SC/LC, 10m Length NOTE: Other configurations and lengths are available; contact your local CSC Representative Singlemode SC/SC, 1m Length Singlemode SC/SC, 2m Length Singlemode SC/SC, 3m Length Singlemode SC/SC, 5m Length Singlemode SC/SC, 10m Length Singlemode ST/SC, 1m Length Singlemode ST/SC, 2m Length Singlemode ST/SC, 3m Length Singlemode ST/SC, 5m Length Singlemode ST/SC, 10m Length Singlemode ST/ST, 1m Length Singlemode ST/ST, 2m Length Singlemode ST/ST, 3m Length Singlemode ST/ST, 5m Length Singlemode ST/ST, 10m Length Singlemode SC to LC, 1m Length Singlemode SC to LC, 2m Length Singlemode SC to LC, 3m Length Singlemode SC to LC, 5m Length Singlemode SC to LC, 10m Length MT-RJ Cable Assemblies MT-RJ two-fiber cable assemblies are factory terminated and tested. They enable connection directly to MT-RJ based electronics or to legacy products (SC or ST based) via hybrid assemblies. Custom lengths or configurations are available upon request. MT-RJ to MT-RJ MT-RJ to SC Multimode Cable Assembly 50/125 μm Multimode Cable Assembly 62.5/125 μm Singlemode Cable Assembly NOTE: Assemblies shown are 3 meter. Available in other lengths. Change -3 to denote desired length in meters: 1 = 1, 2 = 2, 5 = 5 or 1-0 = 10. MT-RJ to ST Multimode Cable Assembly 50/125 μm Multimode Cable Assembly 62.5/125 μm Singlemode Cable Assembly NOTE: Assemblies shown are 3 meter. Available in other lengths. Change -3 to denote desired length in meters: 1 = 1, 2 = 2, 5 = 5 or 1-0 = Duplex Multimode Cable Assembly 50/125 μm Duplex Multimode Cable Assembly 62.5/125 μm Duplex Singlemode Cable Assembly Simplex Multimode Cable Assembly 50/125 μm Simplex Multimode Cable Assembly 62.5/125 μm NOTE: Assemblies shown are 3 meter. Available in other lengths. Change -3 to denote desired length in meters: 1 = 1, 2 = 2, 5 = 5 or 1-0 = 10. MT-RJ to LC Multimode Cable Assembly 50/125 μm Multimode Cable Assembly XG Fiber Multimode Cable Assembly 62.5/125 μm Singlemode Cable Assembly NOTE: Assemblies shown are 3 meter. Available in other lengths. Change -3 to denote desired length in meters: 1 = 1, 2 = 2, 5 = 5 or 1-0 = FOR MORE INFORMATION CALL TOLL FREE OR VISIT

19 Fiber Optic Connectivity CONNECTORS & COUPLERS ST Style RoHS Compliant LightCrimp Plus (no epoxy/no polish); Application: MM LightCrimp Plus (no epoxy/no polish); Application: MM LightCrimp Epoxyless Polymer; Application: MM LightCrimp Epoxyless Ceramic; Application: MM ST-Style Polymer (epoxy cure); Application: MM ST-Style Ceramic (epoxy cure); Application: MM LightCrimp Epoxyless Ceramic; Application: SM ST-Style Ceramic (epoxy cure); Application: SM SC Style RoHS Compliant LightCrimp Plus (no epoxy/no polish) Ceramic; Application: MM LightCrimp Plus (no epoxy/no polish) Ceramic; Application: MM LightCrimp (no epoxy/polish) Ceramic, Simplex; Application: MM LightCrimp (no epoxy/polish) Ceramic, Duplex; Application: MM LightCrimp Plus (no epoxy/no polish) Ceramic, Simplex; Application: SM LightCrimp Plus (no epoxy/no polish) Ceramic, Duplex; Application: SM Epoxy Cure, Ceramic, Simplex, 2 Piece; Application: MM Epoxy Cure, Ceramic, Duplex, 2 Piece; Application: MM Epoxy Cure, Ceramic, Simplex, 1 Piece; Application: SM Epoxy Cure, Ceramic, Duplex, 1 Piece; Application: SM Couplers ST to ST, Simplex, Metallic Body; Application: MM Tool Kits & Consumables LightCrimp Plus ST, SC, and LC Termination Kit LightCrimp Plus ST-Style Termination Kit LightCrimp ST-Style Termination Kit, without Microscope LightCrimp SC Termination Kit, with Premium Microscope Combined LightCrimp ST-Style/SC Termination Kit, with Premium Microscope ST-Style Termination Kit, Epoxy Style, without Microscope SC Termination Kit, Epoxy Style, without Microscope FOR MORE INFORMATION CALL TOLL FREE OR VISIT 17

20 Fiber Optic Connectivity CONNECTORS & COUPLERS MT-RJ Workstation Jacks This two-fiber, pre-polished, epoxyless, and reusable fiber jack fits into existing RJ45 style jack workstation faceplate openings and most conventional wall boxes. The MT-RJ workstation jack length has been reduced so that it is now comparable to a copper jack. This feature reduces the possible interference with outlet boxes or furniture raceway systems. It can be re-terminated and is suitable for use with industry-standard fiber cable or ribbon fiber innovations. The kit includes a one-piece jack, a dust cover, and a disposable actuator key MT-RJ Jack, Multimode 50/125 μm (almond) MT-RJ Jack, Multimode 62.5/125 μm (almond) MT-RJ High-Density Patch Panel Jacks High-density, two-fiber jacks are epoxyless, reusable, and pre-polished for consistent performance. Jacks fit into 6-position snap-in adapter plate in the AMP Solarum Patch Panel, which enables 24 ports in a 1U space, equaling the density of copper. The jacks also fit into a snap-in adapter plate for use in existing rack and wall-mount enclosures. Jacks are used with industrystandard fiber cable or ribbon fiber innovations. The kit includes six patch panel jacks, dust covers, two actuator keys, an icon wheel, and both 90 μm and 250 μm fiber guide (beige = MM, blue = SM) MT-RJ Jack for 250 μm Coated Fiber Terminations, Multimode 50/125 μm (pack of 6 pieces), Black MT-RJ Jack for 250 μm Coated Fiber Terminations, Multimode 62.5/125 μm (pack of 6 pieces), Beige MT-RJ Jack for 900 μm Coated Fiber Terminations, Multimode 50/125 μm (pack of 6 pieces), Black MT-RJ Jack for 900 μm Coated Fiber Terminations, Multimode 62.5/125 μm (pack of 6 pieces), Almond Tool Kits & Consumables MT-RJ Jack Termination Kit Tool Kit for Termination of MT-RJ Jacks; Contents: Cleave Tool, Miller Strip Tool, Cable Stripper, Micro Stripper, Scissors, MT-RJ Jack Strip Length Template, Actuator Key, Alcohol Wipes, Soft Case Universal Termination Kit Tool Kit for Termination of LightCrimp, LightCrimp Plus, and MT-RJ Jacks 18 FOR MORE INFORMATION CALL TOLL FREE OR VISIT

SECURE Fiber Optic Products

SECURE Fiber Optic Products SECURE Fiber Optic Products LC SECURE Fiber Optic Products (Pages 9 and 10) LC SECURE Connectors, Cable Assemblies and Adapters MPO SECURE Fiber Optic Products (Pages 11 and 12) MPO SECURE Cable Assemblies

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

AMP NETCONNECT Product Catalog. Our commitment. Your advantage.

AMP NETCONNECT Product Catalog. Our commitment. Your advantage. AMP NETCONNECT Product Catalog TM Our commitment. Your advantage. CONTACTS Visit our website at :: Instruction Sheets :: Cut Sheets :: White Papers :: Data Sheets :: Product/Part Number Searches :: AMP

More information

Patch Cords for Data Center Applications

Patch Cords for Data Center Applications Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails

More information

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions TABLE OF CONTENTS TABLE OF CONTENTS... 2 INTRODUCTION... 3 CABLING

More information

AMP NETCONNECT. EMEA Product Catalog

AMP NETCONNECT. EMEA Product Catalog AMP NETCONNECT EMEA Product Catalog What s New! & System Selector What s New...2 System Selector... 4 Table of Contents AMP NETCONNECT Systems by Name 1. MRJ21 System... 9 2. Sigma-Link System...15 3.

More information

AMP NETCONNECT Data Center Cabling Solutions

AMP NETCONNECT Data Center Cabling Solutions AMP NETCONNECT Data Center Cabling Solutions Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

Physical & Network Security Infrastructure Solutions

Physical & Network Security Infrastructure Solutions Physical & Network Security Infrastructure Solutions people. passion. expertise. gocsc.com What is the Secure(it) Program? Secure(it) is a bundle of the industry s latest solutions, designed to protect

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

Reliable, Consistent, Quality

Reliable, Consistent, Quality Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic

More information

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8 Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,

More information

Pretium Connector Housings

Pretium Connector Housings Pretium Connector Housings A LANscape Pretium Solutions Product Applications Main cross connect, intermediate cross connects and telecommunications rooms Rack or equipment cabinet installations Data center

More information

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

Developing the Green Data Center

Developing the Green Data Center Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Developing the Green Data Center Introduction...5 Airflow Management in the Data Center...6 Angled Panels Glide Cable

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

Innovative Connectivity Solution for Maximum Performance and Security

Innovative Connectivity Solution for Maximum Performance and Security Innovative Connectivity Solution for Maximum Performance and Security Financial Institutions Supports high performance backbone which enables transfer of real-time financial information through voice,

More information

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch

More information

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM

AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM AMP NETCONNECT TM AMPTRAC TM CONNECTIVITY MANAGEMENT SYSTEM The AMPTRAC Connectivity Management System turns cabling systems and their connected devices into intelligent networks by reducing costly and

More information

Cable Assembly Solutions at the Speed of Light

Cable Assembly Solutions at the Speed of Light Cable Assembly Solutions at the Speed of Light Peggy Kovling ACI Founder Peggy Kovling credits her extensive knowledge of the cable business, along with her abilities in customer relationship management,

More information

THE AMP NETCONNECT MT-RJ OPTICAL FIBER SYSTEM

THE AMP NETCONNECT MT-RJ OPTICAL FIBER SYSTEM THE AMP NETCONNECT MT-RJ OPTICAL FIBER SYSTEM The Most Significant Development In Fiber Optic Connectivity Is Now The Connectivity Choice For The Networks Of Today And Tomorrow 2 TABLE OF CONTENTS The

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

Uniprise Solutions. Information Security Network Solutions

Uniprise Solutions. Information Security Network Solutions Uniprise Solutions Information Security Network Solutions Information Security Network Solutions Companies today face the challenges of maintaining data security throughout the enterprise. Network managers

More information

The AMP NETCONNECT Cabling System Products

The AMP NETCONNECT Cabling System Products The AMP NETCONNECT Cabling System Products About the AMP NETCONNECT Business Unit The AMP NETCONNECT business unit of Tyco Electronics develops, manufactures and supplies a comprehensive range of communications

More information

ADC-APC Integrated Cisco Data Center Solutions

ADC-APC Integrated Cisco Data Center Solutions Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the

More information

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution

More information

Data Centre & Enterprise Solutions. RapidNet

Data Centre & Enterprise Solutions. RapidNet H E L L E R M A N N T Y T O N Data Centre & Enterprise Solutions RapidNet data centre & Enterprise solutions HellermannTyton is a leading global manufacturer of network cabling solutions which connect,

More information

ADC Structured Cabling Solutions

ADC Structured Cabling Solutions ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large

More information

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.

More information

INTELLIGENT INFRASTRUCTURE MANAGEMENT

INTELLIGENT INFRASTRUCTURE MANAGEMENT F/ System F/ Assemblies, 9.0 W W W. S I E M O N. C O M SECTION CONTENTS System...............................9. IM Software........................... 9. Analyzers..............................9. System

More information

1st Edition Ethernet/Data Connectivity

1st Edition Ethernet/Data Connectivity 1st Edition Ethernet/Data Connectivity Distribution Frames Patch Panels Accessories Table of Contents Distribution Frame Introduction...1 Ethernet Distribution Frame...5 Glide Cable Manager...6 Patch

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

Belden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems

Belden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems Belden Optical Fiber Catalog One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems With the IBDN FiberExpress Systems, Belden takes a complete approach to fiber optic cabling.

More information

Panduit 28 AWG Patch Cords Installation Guideline

Panduit 28 AWG Patch Cords Installation Guideline Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

Cable Installation Project

Cable Installation Project Cable Installation Project 1. Intent. It is the intent of the U.S. Court of Appeals to install Category 6 (CAT6) data cabling in the Robert F. Peckham Federal Building and United States Courthouse, 280

More information

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

IT Cabling Solutions

IT Cabling Solutions IT Cabling Solutions Signamax & Hitachi Cable America System Performance Signamax & Hitachi Cable America (Hitachi) system quality assurance testing is based on the worst-case model - four-connector 100-meter

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

Secure/Keyed LC System Solutions Overview

Secure/Keyed LC System Solutions Overview Secure/Keyed LC System Solutions Overview Designing performance and efficiency into your secure network Introduction In recent years, physically discrete fiber connection systems have emerged to respond

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

SECTION 16750 VOICE AND DATA COMMUNICATION CABLING

SECTION 16750 VOICE AND DATA COMMUNICATION CABLING SECTION 16750 VOICE AND DATA COMMUNICATION CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Store drawing set and general provisions of the Contract, including General and Supplementary Conditions and

More information

Copper Closet. Copper Closet

Copper Closet. Copper Closet Copper Closet Copper Closet Copper Closet Contents: CC-2 CC-5 CC-8 CC-12 CC-13 CC-14 CC-17 Limited Axcess Category 6a Solutions Patch Panels Cable Assemblies Category 6 Patch Cords 110 Wiring Products

More information

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications 3M Telecommunications Solutions for Networks Volition Network Solutions Leading the way in Network Migration through Innovative Connectivity Solutions Innovation The Broadband Migration Path 3M TM Volition

More information

InstaPATCH Cu Cabling Solutions for Data Centers

InstaPATCH Cu Cabling Solutions for Data Centers SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 Instapatch Cu Solution Specification 2 Harness Assembly Design 3

More information

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS Document ID: WP-07-01-ENG Original Issue Date: May 2007 Version: 1.0 FTE Cabling Best Practices 1 Table of Contents Introduction and Applicable Standards...3

More information

AMPTRAC CONNECTIVITY MANAGEMENT SYSTEM

AMPTRAC CONNECTIVITY MANAGEMENT SYSTEM Connectivity Management System CONNECTIVITY MANAGEMENT SYSTEM Analyzers............................................................232 Twisted Pair Patch Panels............................................

More information

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS Bandwidth Requirements Push Fiber Optic Solutions Offices, Operations

More information

Pretium EDGE HD Solutions

Pretium EDGE HD Solutions Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE HD Solutions create a fiber optic tip-to-tip solution for Data Centers and Storage Area

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope.

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope. SYSTIMAX Solutions GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions www.commscope.com The SYSTIMAX GigaSPEED X10D Shielded Solution provides unprecedented performance

More information

Plug & Play Universal Systems

Plug & Play Universal Systems Plug & Play Universal Systems A LANscape Pretium Plug & Play Universal Systems for Data Centers and Storage Area Networks (SANs) Corning Plug & Play universal systems create a fiber optic tip-to-tip solution

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems Rudolph A Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand November, 006 Introduction: Optical communication systems provide

More information

hot products guide people. passion. expertise. gocsc.com

hot products guide people. passion. expertise. gocsc.com hot products guide gocsc.com who is CSC? Founded in 1972, Communications Supply Corporation (CSC), a subsidiary of WESCO International, Inc. (NYSE: WCC), distributes a full range of IP infrastructure and

More information

Copper Pre-terminated Assemblies

Copper Pre-terminated Assemblies Copper Pre-terminated Assemblies Copper Pre-Terminated Trunk Assemblies Overview Copper Pre-Terminated trunk assemblies are the perfect solution for Enterprise / Premise & Data Centre applications where

More information

Belden. Copper Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN Copper Systems

Belden. Copper Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN Copper Systems Belden Copper Catalog One Enterprise. One Infrastructure. One Partner. Belden IBDN Copper Systems Belden has the end-to-end copper cabling system to meet your current networking challenges while providing

More information

Developing the Green Data Centre

Developing the Green Data Centre Products and Solutions to Support Energy Efficiency Ordering Guide Table of Contents Supporting the Green Data Centre Table of Contents Introduction...5 Airflow Management in the Data Centre...6 Angled

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

MapIT G2 Infrastructure Management

MapIT G2 Infrastructure Management MapIT G2 Infrastructure Management Introducing MapIT G2, a complete upgrade of Siemon s popular MapIT intelligent infrastructure management (IIM) solution. MapIT G2 integrates a powerful combination of

More information

Network Infrastructure Security Solution

Network Infrastructure Security Solution Network Infrastructure Security Solution Network Infrastructure Security Solution Technology has rapidly become a critical asset for driving improvements in operational and financial efficiencies. With

More information

7.4 3M No Polish Connector

7.4 3M No Polish Connector Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector

More information

DEPARTMENTAL REGULATION

DEPARTMENTAL REGULATION U.S. DEPARTMENT OF AGRICULTURE WASHINGTON, D.C. 20250 DEPARTMENTAL REGULATION SUBJECT: Service Center Technology Modernization Project (SCTMP) Wiring/Cabling Specifications for Service Center Agencies

More information

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection.

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection. DIVISION 16 ELECTRICAL Section 16740 Telephone System PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects. FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in

More information

Keyed LC Connector Solution

Keyed LC Connector Solution features and benefits Eight color-coded mechanical key positions Meets TIA/EIA-568-B requirements Keyed connectors and adapters Full solution availability Keyed LC Connectors Photo LAN758 SPECIFICATION

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

Network Infrastructure Security Solution

Network Infrastructure Security Solution Network Infrastructure Security Solution Network Infrastructure Security Solution Technology has rapidly become a critical asset for driving improvements in operational and financial efficiencies. With

More information

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011)

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011) Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011) A. Objectives The Information Technology (IT) Department of Embry-Riddle Aeronautical University (ERAU) seeks to establish a standards-based

More information

Cat7/Class F New Installation Concept New infrastructure. Handbook

Cat7/Class F New Installation Concept New infrastructure. Handbook Cat7/Class F New Installation Concept New infrastructure Handbook contents 1 Introduction 3 2 What is the Cat7/Class F installation concept 3 3 Distribution centre 3 3.1 Patch Modules 3 4 How to handle

More information

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines This document contains critical information regarding the installation of a certified SYSTIMAX SCS that meets or exceeds performance

More information

1U Multi-Function Fibre Enclosure

1U Multi-Function Fibre Enclosure FEATURES AND SPECIFICATIONS Features and Benefits The is a configurable rack mount unit for storing and terminating incoming fibre cable. The fibre enclosure has been designed to accommodate various termination

More information

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd

More information

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS AMPINNERGY Modular Power Distribution System................... 270 Raised Access Floor/Zone Wiring Distribution System................ 270

More information

Standards Affecting a Premise T-1 Installation

Standards Affecting a Premise T-1 Installation Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

How To Make A Data Center More Efficient

How To Make A Data Center More Efficient Data Center: Technology Drivers Infrastructure Trends 40G / 100G Migration Maurice F. Zetena III Vice President Leviton Technology Data Center Group Leviton Network Solutions Technology Drivers Convergence

More information

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com DATA CENTER NETWORK INFRASTRUCTURE Cable and Connectivity for the Most Demanding Networks Customer-focused, technology-driven, quality-assured for an unparalleled RETURN ON infrastructure investment DATA

More information

Ethernet Cat 5e & Cat 6 Patch Panels

Ethernet Cat 5e & Cat 6 Patch Panels Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e

More information

Intelligent Infrastructure Management System

Intelligent Infrastructure Management System Intelligent Infrastructure Management System System Overview AMPTRAC Hardware Overview Unused Port Patched Port AMPTRAC System and Components AMPTRAC Basic Operating Principle Robust th wire in patch cords

More information

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Enterprise Networks EMEA. Core Products FOR DATA CENTRES Enterprise Networks EMEA Core Products FOR DATA CENTRES EMEA Data Centre Core Products 1 Data Centres GET IT RIGHT, Right Now. Corning Cable Systems offers tens of thousands of fibre optic products for

More information

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Product Family: Product: Fibre: LANscape Hardware Solutions FCS-FCT-FCP Housings and Connector Panels InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2 Applications Corning Cable

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

Copper Patch Cords. Impact On Network Performance and Reliability

Copper Patch Cords. Impact On Network Performance and Reliability Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on

More information

AMP CO Ultra System Catalog

AMP CO Ultra System Catalog Catalog Table of Contents AMP CO Ultra Panels... 1 AMP CO Ultra Outlets... 3 AMP CO Inserts... 7 AMP CO Tools...16 AMP CO Ultra Panels AMP CO Ultra 24 Port High Density Patch Panel 19 2 U Patch Panel for

More information

integrated communication solution copper

integrated communication solution copper integrated communication solution copper integrated communication solution copper Contents: CC Copper Closet WS Workstation CU Copper UTP Cable AFC Group s range of integrated communication products includes

More information

www.commscope.com Data Center Topology Guide

www.commscope.com Data Center Topology Guide www.commscope.com Data Center Topology Guide Data Center Areas 1 Network Operations Center (NOC) The network operations center or NOC is the location where control of all data center networking, server

More information

114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification

114-22008. 8-Position Cat5e (EMT) Modular Plug Connectors. Application Specification Application Specification 114-22008 02/May/2008 Rev H 8-Position Cat5e (EMT) Modular Plug Connectors NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are

More information

Cable Assemblies. Corning Cable Systems

Cable Assemblies. Corning Cable Systems Corning Cable Systems OptiFit Node Assembly Photo CAPSS1721 Description As the industry s leading supplier of single-mode cable assemblies, Corning Cable Systems offers the most complete line of connectors

More information

November/December2007. president s message 3. BICSInewsadvancing. bicsi update 34-35 course schedule 36-37 standards report 38. Volume 28, Number 6

November/December2007. president s message 3. BICSInewsadvancing. bicsi update 34-35 course schedule 36-37 standards report 38. Volume 28, Number 6 November/December2007 BICSInewsadvancing president s message 3 EXECUTIVE DIRECTOR MESSAGE 4 bicsi update 34-35 course schedule 36-37 standards report 38 Volume 28, Number 6 Making Sense of TIA-942 Data

More information