Basics of RF Amplifier Test with the Vector Network Analyzer (VNA)



Similar documents
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Impedance 50 (75 connectors via adapters)

High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Keysight Vector Network Analyzer Calibration and Connector Care. Timothy Lee Keysight Technologies Australia Pty Ltd Application Engineer

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

Power Amplifier Gain Compression Measurements

Agilent Test Solutions for Multiport and Balanced Devices

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Techniques for precise cable and antenna measurements in the field

Agilent 8753ET/8753ES Network Analyzers

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Agilent 8720 Family Microwave Vector Network Analyzers

Agilent. E5071C ENA Network Analyzer. E5092A Configurable Multiport Test Set. Data Sheet

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Agilent Network Analyzer Selection Guide

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

iva Cable & Antenna Analyzer

Antenna Measurements with the Network Analyzer. Presented by Ernie Jackson RF/uW Applications Engineer Agilent Technologies

RF Network Analyzer Basics

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

A Network Analyzer For Active Components

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

R&S ZNBT8 Vector Network Analyzer Specifications

Basic of Load Pull Measurements Active and Passive load pull & Harmonic load pull testbench

Agilent PNA Network Analyzers 10 MHz to 110 GHz

Agilent Millimeter-Wave Network Analyzers 10 MHz to 110 GHz, with Extensions to 0.5 THz

One Port Network Analyzer

Agilent 10 Hints for Making Better Network Analyzer Measurements. Application Note B

Keysight Technologies Compatibility of USB Power Sensors with Keysight Instruments. Application Note

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Field Calibration Software

iva Cable & Antenna Analyzer

DRM compatible RF Tuner Unit DRT1

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

E5092A Configurable Multiport Test Set

How To Use A Sound Card With A Subsonic Sound Card

Experiment 7: Familiarization with the Network Analyzer

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

R&S ZNC Vector Network Analyzer Specifications

2. The Vector Network Analyzer

HP 8970B Option 020. Service Manual Supplement

khz to 2.7 GHz Spectrum Analyzer

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports

Improving Network Analyzer Measurements of Frequency-translating Devices Application Note

A Guide to Calibrating Your Spectrum Analyzer

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide

MASW T. HMIC TM PIN Diode SP2T 13 Watt Switch for TD-SCDMA Applications. Features. Functional Diagram (TOP VIEW)

Keysight Technical Training Catalog

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

R&S ZVA Vector Network Analyzer High performance up to 67 GHz with up to four test ports

Agilent E5100A Network Analyzer

Agilent Network Analyzer Selection Guide

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m

Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview

R&S ZVA Vector Network Analyzer Specifications

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

R3765/67 CG Network Analyzer

USB Smart Power Sensor

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Michael Hiebel. Fundamentals of Vector Network Analysis

Monolithic Amplifier PMA2-43LN+ Ultra Low Noise, High IP3. 50Ω 1.1 to 4.0 GHz. The Big Deal

Agilent Technologies Measuring Frequency Response with the LF Network Analyzer

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

Keysight Technologies Drive Down the Cost of Test Using the ENA Series of Network Analyzers. Application Note

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

USB Smart Power Sensor

DSA800 Series Spectrum Analyzer

Application Note Noise Frequently Asked Questions

E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

Keysight Technologies N9320B RF Spectrum Analyzer

Product Datasheet P MHz RF Powerharvester Receiver

Keysight N9320B RF Spectrum Analyzer

Understanding Mixers Terms Defined, and Measuring Performance

USB Smart Power Sensor

Advanced Nonlinear Device Characterization Utilizing New Nonlinear Vector Network Analyzer and X-parameters

Agilent U2000 Series USB Power Sensors

Symbol Parameters Units Frequency Min. Typ. Max. 850 MHz

Optimizing IP3 and ACPR Measurements

VCC1,2. H/L Lin. Bias, Enable, Detector Circuits

Agilent E5061B Network Analyzer 5 Hz to 3 GHz. Data Sheet

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Cable Analysis and Fault Detection using the Bode 100

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP

NI USB-5681 RF Power Meter Specifications

Introduction to Network Analyzer Measurements

R&S ZCxxx Millimeter-Wave Converters Specifications

SKY LF: 20 MHz-3.0 GHz High Power SP4T Switch With Decoder

Ideal for high dynamic range measurements from compression to noise floor

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

Transcription:

Basics of RF Amplifier Test with the Vector Network Analyzer (VNA) Taku Hirato Product Marketing Engineer CTD-Kobe, EMG Agilent Technologies Mar. 13, 2012

Objectives Understand what types of amplifier measurements are made with RF VNAs. S-parameter / Stability factor (K-factor) Measurements with power leveling Gain compression (P1dB compression point) Pulsed-RF measurements Intermodulation distortion (IMD) Understand associated key features of the modern VNAs 2

Agenda Agilent VNA Portfolio Amplifier Test - Measurement Parameters S-parameter / Stability factor (K-factor) Measurement with power leveling Gain compression (P1dB compression point) Pulsed-RF measurement Intermodulation Distortion (IMD) Summary Page 3

Agilent VNA solutions PNA-X, NVNA Industry-leading performance 10 M to 13.5/26.5/43.5/50/67 GHz Banded mm-wave to 2 THz FieldFox Handheld RF Analyzer 5 Hz to 4/6 GHz E5061B NA + ZA in one-box 5 Hz to 3 GHz Low cost RF VNA E5071C World s most popular economy VNA 9 khz to 4.5, 8.5 GHz 300 khz to 20.0 GHz E5072A Best performance ENA 30 khz to 4.5, 8.5 GHz 100 k to 1.5/3.0 GHz ENA Series PNA Performance VNA 10 M to 20, 40, 50, 67, 110 GHz Banded mm-wave to 2 THz PNA-L World s most capable value VNA 300 khz to 6, 13.5, 20 GHz 10 MHz to 40, 50 GHz PNA-X receiver 8530A replacement Mm-wave solutions Up to 2 THz PNA Last update:

E5072A = 8753x + 2-port RF E5071C and More. E5072A HP/Agilent 8753x Enhanced power calibrations (Power cal / Receiver cal / Receiver leveling) >150 db wide dynamic range Wide power range (available from -109 to +20 dbm) E5071C RF Options (4.5 / 6.5 / 8.5 GHz) Configurable test set Direct receiver access (S/R/A/B port) Higher power output (up to +20 dbm) High-gain amp measurement (with very low power down to -85 dbm) Basic 2-port measurement Frequency Offset Mode (FOM) Time domain analysis Faster speed Better performance Powerful software analysis Connectivity Upgrade of all options Multiport (>2-port) Opt.TDR

Production Lab. ENA Series Application Mapping Wireless E5071C Wireline E5072A E5061B LF-RF NA option Computer Auto motive Passive Active Power integrity Inter connects E5061B RF NA options Industry/Science /Medical BTS filter tuning Differential components Multiport devices Chip antenna test RFID Antenna evaluation Front end module test RF amp test Mixer test DC/DC converter evaluation Impedance evaluation EMC components evaluation High speed digital Cable/PCB test with Option TDR www.agilent.com/find/ena Material measurements On-wafer measurements Power amp test EMC components evaluation Gain/Phase measurements CATV 75 ohm components MRI coil tests Coax. cable test

Production Lab. ENA Series Application Mapping Wireless E5071C Wireline E5072A E5061B LF-RF NA option Computer Auto motive Passive Active Power integrity Inter connects E5061B RF NA options Industry/Science /Medical BTS filter tuning Chip antenna test RFID Antenna evaluation Differential components Multiport devices Front end module test RF amp test Mixer test DC/DC converter evaluation Impedance evaluation EMC components evaluation High speed digital Cable/PCB test with Option TDR Material measurements On-wafer measurements Power amp test E5072A is best www.agilent.com/find/ena suited for amplifier test EMC components evaluation Gain/Phase measurements CATV 75 ohm components MRI coil tests Coax. cable test

Agenda Agilent VNA Portfolio Amplifier Test - Measurement Parameters S-parameter / Stability factor (K-factor) Measurement with power leveling Gain compression (P1dB compression point) Pulsed-RF measurement Intermodulation Distortion (IMD) Summary

Amplifier Test - S-parameters Linear transmission and reflection measurements are performed with a single connection with the VNA. Gain, gain flatness, phase, group delay,, (S21) Input match, input impedance, VSWR, (S11) Output match, output impedance, VSWR, (S22) Reverse isolation (S12) S11 S12 S21 S22

Amplifier Test - Stability Factor (K-factor) K-factor calculated from all the four S-parameters (S11, S12, S21 and S22) and represents the stability of amplifiers Definition of K-factor S11 S12 S22 Note: When K-factor > 1 while delta is < 1, the amplifier is unconditionally stable for any load. S21 Measurement Challenges: K-factor is calculated from all four S-parameters and should be displayed in real-time. All four S-parameters must be accurate for calculation of K-factor.

VNA Features Equation Editor Computes measurement results and add a new trace to the display. Equations can be based on any combination of existing traces or parameters or constants. Easy setup with pre-defined parameters such as K-factor, μ-factor, maximum available power gain, or maximum stable power gain etc.

Amplifier Test - S-parameters High-gain amplifier outputs high-power above the maximum input level of VNA s receivers. Port 1 Port 2 Optional attenuator to protect VNA s receivers DUT: Highgain amp Measurement Challenges: Dealing with high-gain and high output power of the amplifiers. => Useful VNA Features Uncoupled power Configurable test set / Direct receiver access

VNA Features Uncoupled power Different output power level can be set for port 1 & 2 with independent built-in attenuators. Easy characterization of high-gain power amp without an external attenuator on output port. More accurate reverse measurement (i.e. S12, S22) with wider dynamic range. Block diagram of Agilent E5072A R1 R2 A B ATT = 40 db (Port 1) -85 dbm 0 dbm DUT ATT = 0 db (Port 2)

S-parameters & K-factor Measurement Example DUT: 30 db RF Amp Coupled power (Port 1 = Port 2 = -40 dbm) Uncoupled power (Port 1 = -40 dbm, Port 2 = 0 dbm) S11 S12 S11 S12 S22 S22 S21 S21 K-factor K-factor More accurate S12 measurement with uncoupled power results in better trace of calculated K-factor. 14

S-parameters (High-power amplifier) Configuration with output attenuator Dealing with high output power from high-power amplifier is a challenge. Typical 2-port configuration with large attenuation Measurement example of high-power amplifier R1, A R2, B S22 S11 = A/R1 S12 = A/R2 S22 = B/R2 DUT (High-power amp) Large Attenuator S21 = B/R1 Measurement Challenge: Large output attenuation is necessary for receiver protection; S/N ratio of S22 is significantly degraded because of very low signal input to receiver B. 15

VNA Features Configurable Test Set / Direct Receiver Access The VNA with configurable test set option is associated with six SMA connectors on front. The test configuration can be modified by accessing source / receivers directly. Agilent E5072A Receiver A Input Receiver B Input Receiver R1 Input Receiver R2 Input

S-parameters (High-power amplifier) Configuration using direct receiver access Configuration using direct receiver access Measurement example of high-power amplifier R1, A B S22 R2 S11 = A/R1 S12 = A/R2 Attenuator (optional) S21 = B/R1 S22 = B/R2 DUT (High-power amp) Coupler Circulator / Isolator An alternative configuration is provided by using the direct receiver access and appropriate external components. More accurate reverse measurements (i.e. S22) can be performed. 17

S-parameters (High-power amplifier) Input power level at VNA s receivers Typical 2-port configuration (with large attenuation on output port) Using direct receiver access R1 A -86 dbm -50 dbm B R2 R1 A B R2-26 dbm -86 dbm -20 dbm -50 dbm 0 dbm Forward measurement 0 dbm -60 dbm 30 db ATT 0 dbm Reverse measurement 0 dbm Forward measurement 30 db ATT 10 dbm -20 dbm 0 dbm Reverse measurement -30 dbm 0 dbm 30 dbm DUT 0 dbm DUT coupler isolator 30 dbm 10 dbm 0 dbm Higher input power to the receiver B means guarantees the enough S/N ratio for reverse measurements (i.e. S22) with a test configuration using direct receiver access.

Agenda Agilent VNA Portfolio Amplifier Test - Measurement Parameters S-parameter / Stability factor (K-factor) Measurement with power leveling Gain compression (P1dB compression point) Pulsed-RF measurement Intermodulation Distortion (IMD) Summary Page 19

Amplifier test with leveled power Some power-sensitive amplifiers are characterized when its input power (Pin) or output power (Pout) across frequency range is very flat at a specified value. Gain vs. Frequency Gain (S21) (1) Leveled input power (2) Leveled output power Absolute Power (dbm) Output power (Pout) Absolute Power (dbm) Output power (Pout) Frequency Input power (Pin) Frequency Input power (Pin) Frequency Measurement Challenges: Power leveling of DUT s input or output power within the tolerance of DUT s specifications.

Measurements with leveled power Current solution for power leveling Typical setup of leveling output power (Pout) System Controller e.g. GPIB Pout (dbm) SG s source power is adjusted. Power Sensor Target tolerance SG Pin DUT Pout Coupler SA Frequency Procedure of leveling output power 1. SG s source power is set for a certain measurement point. 2. DUT s output power (Pout) is monitored by power sensor via coupler. 3. SG s output power is calibrated to adjust Pout within the DUT s specification. 4. The power leveling process is continued for all measurement points. Measurement Challenges: The leveling process takes long time. Necessary to reduce time for faster measurement.

VNA features Receiver leveling Adjusts the source power level across frequency or power sweep range using its receiver measurements. The complexity of rack and stack test system for external power leveling can be reduced. Leveling with rack & stack system Leveling with VNA s receiver leveling Agilent E5072A System Controller e.g. GPIB V SG s source power is adjusted. Power Sensor SG Pin Coupler Pout DUT SA Pout DUT Receiver leveling offers fast leveling of DUT s output power with a single instrument.

Measurement with leveled power DUT: 30 db RF Amplifier. Target power (Pin or Pout) = -10 dbm. R1 B Pin Pout Leveled input power (Pin) Leveled output power (Pout) (with receiver leveling with B) Gain (S21) Gain (S21) Pin Pout Pin Pout Ref = -10 dbm, 0.1 dbm/div Ref = -10 dbm, 0.1 dbm/div DUT s Pin and Pout can be monitored with absolute measurements with the VNA Receiver leveling of the VNA accurately adjusts Pin & Pout at target power level (i.e. -10 dbm)

Agenda Agilent VNA Portfolio Amplifier Test - Measurement Parameters S-parameter / Stability factor (K-factor) Measurement with power leveling Gain compression (P1dB compression point) Pulsed-RF measurement Intermodulation Distortion (IMD) Summary Page 24

Output Power (dbm) Gain (i.e. S21) What is gain compression? Parameter to define the transition between the linear and nonlinear region of an active device. The compression point is observed as x db drop in the gain with VNA s power sweep. Linear region Compression (nonlinear) region x db Input Power (dbm) Input Power (dbm) 25

The higher, the better! Enough margin of source power capability is needed for analyzers. ex.) Long-distance test Pin DUT Gain (S21) Sufficient power level to drive DUT Output power is not high enough to compress DUT. VNA Signal loss associated with: Long RF cables, probes, min loss pads (50-to-75 ohm conversion) etc. Input Power (Pin, dbm) Measurement Challenges: Driving DUT with high power Due to loss in the signal path, necessary to boost power to DUT s input for compression measurements. 26

VNA features Higher output power The E5072A has the maximum power with +20 dbm available from the test port. (up to 1 GHz) Wide power sweep (> 65 db) can be done for compression test with a single sweep. Output power level comparison >65 db wide power sweep Power sweep

Gain compression with high-power External booster amps are needed for higher power than the analyzer's source. ex.) High-power test system with a booster amp SG Booster amp Pin DUT SA Gain Actual Pin (dbm) tolerance Target tolerance Frequency When temperature changes, the gain changes.. Target Pin (dbm) Actual input power becomes out of tolerance. Measurement Challenges: Power leveling - Eliminating short-term drift of a booster amplifier s gain; variation of input power to DUT. 28

Gain compression with high-power Power leveling Typical setup of leveling high input power (Pin) SG s source power is adjusted. e.g. GPIB System Controller Actual Pin (dbm) tolerance Power Sensor SG Booster amp Coupler Pin DUT SA Target Pin (dbm) Procedure of leveling input power 1. SG s source power is set for a certain measurement point. 2. Pin is monitored by power sensor via high-power coupler. 3. SG s output power is calibrated to adjust Pin within the DUT s specification / tolerance. 4. The power leveling is performed periodically. (i.e. after ambient temperature & booster amp s gain changes.) Measurement Challenges: Power leveling process takes very long time! Test configuration is complicated; necessary to lower overall cost of test systems.

VNA features Receiver leveling Adjusts the source power level across frequency or power sweep range using its receiver measurements. The complexity of rack and stack test system for external power leveling can be reduced. Leveling with rack & stack system Leveling with VNA s receiver leveling E5072A System Controller e.g. GPIB SG s source power is adjusted. Power Sensor ATT (Optional) V SG Booster amp Coupler Pin DUT SA Coupler Booster Pin amp DUT Receiver leveling offers fast and accurate leveling to compensate a booster amp s short-term drift with a simple connection.

Leveled high-power with receiver leveling Configuration of leveled high-power test Input power (Pin) with receiver leveling ON & OFF Pin (dbm) R1 Receiver leveling ON ATT (Optional) Booster amp High-power Coupler Pin +43 dbm DUT 0.1 dbm/div Receiver leveling OFF Note: frequency sweep is performed to monitor Pin over frequency. DUT s Pin is accurately adjusted at target power level of +43 dbm by using receiver leveling with the VNA.

Agenda Agilent VNA Portfolio Amplifier Test - Measurement Parameters S-parameter / Stability factor (K-factor) Measurement with power leveling Gain compression (P1dB compression point) Pulsed-RF measurement Intermodulation Distortion (IMD) Summary Page 32

Why Pulsed Measurement? Device may behave differently between CW and pulsed signals Changes during pulse might affect RF performance CW signal would destroy your DUT High-power amplifiers not designed for CW operation On-wafer device often lack adequate heat sinking Pulsed test power level can be the same as actual operation Example) Pulsed-RF measurement for GSM Power Amp with VNA Agilent Confidential 33

Pulsed-RF Measurement with ENA Test Configuration Example time Agilent 81110A Pulse/Pattern Generator Ext Trig In Agilent E5072A ENA Series Network Analyzer Trigger Out Output 1 Ref In Ref Out Port 1 Port 2 Data acquisition at VNA s receivers time Control Voltage time Attenuator (Optional) RF In RF Out Pulse Modulator DUT RF On RF On time 34

Pulsed Measurement with VNA Timing Chart Pulse Generator Trigger OUT Pulsed RF Signal from pulse generator Delay Pulse Width RF On Period Duty cycle (%) RF On RF On RF On VNA Trigger Input VNA Data Acquisition Td Ts Ta Td Sampling / Data acquisition

Pulsed-RF Measurement Measurement Example Gain of 30 db amplifier: Pulse Width = 5 us, Period = 100 us. Pulsed / Synchronized (Trigger Source = External) CW / Unsynchronized (Trigger Source = Internal) Synchronized pulsed-rf measurement shows the correct frequency response of the DUT in pulsed operation.

Pulsed-RF (with receiver leveling) Configuration Amplifier measurements with power leveling under pulsed condition. Typical setup of leveling input power (Pin) Pulse generator Ex. Trigger input Port 1 R1 B Port 2 DUT Attenuator (optional) Pulsed signal for modulator Pulse modulator Coupler Pin Measurement Challenges: Accurate power leveling of input power (Pin) in pulsed operation.

Pulsed-RF (with receiver leveling) Measurement Example Gain of 30 db amplifier: Pulse Width = 5 us, Period = 100 us. R1 R 1 Pin B Pout Gain Data trace (With receiver leveling) 0.5 db/div Memory trace (Without receiver leveling) Pin Pout 0.1 dbm/div 0.5 dbm/div Input power level at DUT is adjusted by receiver leveling. Useful for characterization of power-dependent performance or nonlinear operation in pulse mode.

Agenda Agilent VNA Portfolio Amplifier Test - Measurement Parameters S-parameter / Stability factor (K-factor) Measurement with power leveling Gain compression (P1dB compression point) Pulsed-RF measurement Intermodulation Distortion (IMD) Summary Page 39

What is intermodulation distortion (IMD)? A measure of nonlinearity of amplifiers. Two or more tones applied to an amplifier and produce additional intermodulation products. P(F1) DeltaF P(F2) IM3 relative to carrier (dbc) P(2*F1-F2) F_IMD = n * F1 + m * F2 2*F1-F2 F1 F2 2*F2-F1 Frequency 40

IMD Measurement Current solution Typical setup of lmd measurements e.g. GPIB System Controller SA SG x2 DUT Measurement Challenges: It requires a controller to synchronize multiple instruments. If many frequencies must be tested, test time is increased dramatically.

VNA features Frequency Offset Mode Sets different frequency range for the source and receivers. Can be used for harmonics or intermodulation distortion (IMD) measurements with the VNA. Normal Sweep Frequency-offset Sweep Source (Port 1) f1 Receiver (Port 2) f1 Source (Port 1) f1 Receiver (Port 2) f2 Source and receiver are tuned at the same frequency range. (i.e. S-parameter). Source and receiver are tuned at the different frequency range (for harmonics, IMD test etc.)

IMD Measurement Configuration of IMD measurement with VNA Measurement example (sweep delta) SG 10 MHz REF GPIB USB USB/GPIB Interface (i.e. 82357B) f1 (SG) f2 (ENA) ENA Attenuator (Optional) f1 (SG) f2 (ENA) f1 f2 DUT Combiner f_im (ENA) f_im Lo IM3 Power levels of main tones and IM products in swept frequencies can be monitored with the VNA s absolute measurements.

Agenda Agilent VNA Portfolio Amplifier Test - Measurement Parameters S-parameter / Stability factor (K-factor) Measurement with power leveling Gain compression (P1dB compression point) Pulsed-RF measurement Intermodulation Distortion (IMD) Summary Page 44

Summary Modern VNAs have many useful features for amplifier characterization that enable you to: 1. Reconfigure your test system by reducing complexity 2. Simplify time-consuming measurement steps for higher throughput 3. Perform efficient and accurate measurements 45

Application Notes - Available on Agilent Website New application note for RF amplifier test with VNA is available! New Basics of RF Amplifier Measurements with the E5072A (Part Number 5990-9974EN) High-power Measurements with the E5072A (Part Number 5990-8005EN) Visit: www.agilent.com/find/e5072a

47 Questions?

ENA series value add campaign Buy now and get 50% OFF on an USB power sensor! - Get accurate result with easy control - Promotion availability: January 1, 2012 to June 30, 2012. Agilent E5072A ENA Series Network Analyzer Agilent U2000 Series USB Power Sensors + 50% off Best performance ENA 2-port, to 4.5 & 8.5 GHz Power calibration techniques (i.e. receiver leveling) Necessary for power calibrations with the E5072A USB connectivity for automatic plug & play 9 k to 24 GHz and -60 to +44 dbm (sensor option dependent) 48

49 THANK YOU!

Resources E5072A information ENA series web page: http://www.agilent.com/find/ena E5072A web page: http://www.agilent.com/find/e5072a E5072A Configuration Guide: Part number 5990-8001EN E5072A Data Sheet: Part number 5990-8002EN E5072A Quick Fact Sheet: Part number 5990-8003EN E5072A Technical Overview: Part number 5990-8004EN Application Note High-power Measurement using the E5072A (Part Number 5990-8005EN) Basics of RF Amplifier Measurements with the E5072A (Part Number 5990-9974EN) New! TIP: to find any publications online simply enter Pub # or title in search field at: www.agilent.com 50

Appendix

Power-Added Efficiency (PAE) Power-Added Efficiency (PAE) A measure of the power conversion efficiency of amplifiers. The ratio of RF power gain and consumption power. Definition of PAE PAE where P P P out in dc P out P dc P in 100 (%) fundmental output poswer RF drive power DC supplied power PAE represents: the efficiency of power amplifiers / battery operation time of handset. main power consumptions and electricity / cooling cost in BTS systems. => PAE is an important parameter for all amplifiers.

VNA features Receiver calibration Necessary for absolute measurements using the VNA s receivers. An example of a test setup for PAE measurements. AUX connectors (AUX1 & AUX2) on real panel of the E5072A (BNC, +-10 V range) AUX1 AUX2 Port 1 Port 2 Attenuator (Optional) DC power supply Sensing circuit DUT

Equation Tr# Parameter Equation 1 S21 (Log Mag) N/A 2 S21 (Phase) N/A 3 R1 N/A 4 B N/A AUX1 AUX2 5 Aux Input 1 (AI1) N/A 6 Aux Input 2 (AI2) N/A DC power supply Sensing circuit DUT 7 Vsupp data(5) 8 Isupp (data(5) - data(6)) / R - Pout (0.001 * pow(mag(data(4)),2)) - Pin (0.001 * pow(mag(data(4)),2)) / pow(mag(data(1)),2) - Pdc (data(5)*(data(5)-data(6)) / R) 9 PAE 100 * ((0.001 * pow(mag(data(4)),2)) - (0.001 * pow(mag(data(4)),2)) / pow(mag(data(1)),2)) / (data(5) *(data(5)- data(6)) / R) Note R in the equations is the value of a sensing resistor.

PAE Measurement Example DUT: Mini-Circuits ZRL-2400LN+ (1 to 2.4 GHz, 30 db gain), 20 db ATT is added on port 2. Frequency (CW) = 1.126 GHz, IFBW = 1 khz, NOP = 51, Input power (Pin) = -15 to +5 dbm, Response thru cal. Vdc_supply = 10 V Gain compression / AM-to-PM / Pin / Pout / PAE R R1 1 Pin DUT B Pout AM-PM Pin Gain AI1 AI2 Pout Vsupp Isupp PAE (%) PAE calculated by equation editor is displayed.

output power (dbm) What is harmonic distortion? Specified to describe nonlinear behavior of amplifiers. Harmonic level is defined as the difference in absolute power level between the fundamental and the harmonics Expressed in dbc (db relative to carrier) for a specified input or output power Relative to carrier (dbc) fo fo 2fo 3fo... fo 2fo 3fo 56

Harmonic Distortion fo fo 2fo 3fo... SG + SA VNA f1 f1, f2, f3 Using a SG and a SA with CW signals. If many frequencies must be tested, test time is increased dramatically. VNA with frequency-offset mode (FOM) option can set different frequencies at the source and receiver. Real-time swept frequency / power harmonics measurements can be performed. Source power calibration and receiver calibration is available with VNA for accurate absolute power measurements. 57

Harmonic Distortion Measurement results Swept frequency f1 Swept input power f1, f2, f3.. Fundamental (f1) Fundamental (f1) 2nd harmonic (f2) 2nd harmonic (f2) 3rd harmonic (f3) 3rd harmonic (f3) Fundamental frequency (Hz) Fast swept measurements of harmonic distortion measurements. Input power (dbm) Note: DUT s harmonics are displayed with data trace; ENA s source harmonics (filtered with LPF) are displayed with memory trace. 58

VNA features Measurement Wizard ENA series VBA program speeds up measurements of RF amplifiers. Key parameters of amplifiers: S-parameters, harmonics, gain compression (CW or Swept frequency) measurements. Can be downloaded on Agilent.com (www.agilent.com/find/enavba)

VNA features Measurement using wizard f1 f1, f2, f3.. Fund. 2nd 3rd Ch 1 to Ch 5: Power level of fundamental and harmonics (dbm) 4th 5th Harm. (dbc) Ch 6: Harmonics relative to carrier (dbc) Measurement wizard for swept harmonic distortion for the ENA is available on Agilent website. Visit: www.agilent.com/find/enavba

VNA features Amplifier Measurement Wizard Key parameters of amplifiers: S-parameters (K-factor), harmonics, gain compression (CW or Swept frequency). S-parameter & K-factor Swept Harmonics Gain Compression (CW or Swept frequency) S11 S21 K-factor S12 S22 Fund. 4th 2nd 5th 3rd Harm. (dbc) CW Gain vs. Pin AM-PM vs. Pin Pout @ PxdB vs. Pin All the basic amplifier measurements with a simple setup! Swept Gain vs. Pin Pout vs. Pin Pin & Pout @ PxdB vs. Frequency

IMD Measurement Solution with VNA 2x SG + SA SG + VNA Using two SGs and a SA with CW signals. It requires a controller to synchronize instruments. If many frequencies must be tested, test time is increased dramatically. ENA with frequency-offset mode (FOM) option can set different frequencies at the source and receiver. Real-time swept frequency IMD measurements can be performed. Source power calibration and receiver calibration is available with VNA for accurate absolute power measurements. 62

VNA Features Power calibration 1. Source power calibration The VNA s source power level is calibrated using a power sensor to get accurate input power level to DUT. Power level accuracy is directly dependent on the accuracy of the power sensor used. 2. Receiver calibration Necessary for absolute measurements in dbm. Must have a power-calibrated source at the same frequency range. Mathematically removes frequency response in the receiver path and adjusts the VNA s reading to the same as power level in dbm at the calibration plane. Thru 3. Receiver leveling Before each measurement sweep, background sweeps are performed to measure power at the receiver. Power measurements at the receiver are used to adjust the VNA s source power level. Accurate power level adjustment by using high receiver linearity of VNA.

VNA Features (E5072A) Source power calibration You can expect the power at the point of calibration to be within the range of the uncertainty of the power sensor used. At each data point, power is measured using the power meter and the source power level is adjusted until the reading of the power sensor is within the tolerance or the max iteration has been met. Measured Port Power at cal plane (in dbm) Uncorrected power Corrected power Target Power Level Num of Readings: Sets the number of power level measurements. (Averaging factor) Tolerance: Maximum desired deviation from the specified target power. Loss Compen: Compensates for losses when using an attenuator to connect the power sensor. Power Offset: A gain or Loss to account for components between the port and cal plane. For example, the positive value is set if a booster amp is inserted for high-power measurements. Source power + Power offset = Target Power

VNA features Source power calibration Calibration transfers the accuracy of the power sensor, and sets the DUT s input power to be a specified level. At each data point, source power level is adjusted until the reading of the power sensor is within the specified tolerance. Measured power by power sensor (in dbm) Uncorrected power Corrected power tolerance Target Input Power (Pin) Frequency

VNA features Receiver calibration Necessary for absolute measurements using the VNA s receivers. Mathematically removes frequency response In the receiver path and adjusts the reading to the same as the targeted power level. Must have a power-calibrated source at the same frequency. Measured power at receiver B (in dbm) B 0 dbm Calibrated power Power = +0 dbm Attenuator (e.g. 20 db) -20 dbm Uncalibrated power Frequency

E5072A key features 150 db DUT Configurable test set -Easy access to source and receivers -Accurate high-power measurement -Receiver leveling with internal receivers Wide output power range -High output power (max +20 dbm) -Settable from -109 dbm to +20 dbm -Independent output power for port 1 & 2 High receiver sensitivity -Extended dynamic range (> 150 db) -Accurate low-power measurements 4.5 GHz Drop-in Frequency offset measurement -Harmonics measurement -Vector mixer calibration (VMC) -Scalar mixer calibration (SMC) Compatible with 8753 & E5071C -100% code compatible with E5071C -8753 code emulator (cxl) -Same size, U/I etc. 8.5 GHz Upgradability - Upgrade among all hardware & software options 67

Comparison with 8753ES & E5071C Advantages Test frequency Configurable test set (Direct receiver access) Max output power Power range 8753ES 30 k to 3 G / 6 GHz 2-port E5071C (opt.24x, 26x, 28x) 9 k to 4.5 / 6.5 / 8.5 GHz (without bias-tees, opt.xx0) 100 k to 4.5 / 6.5 /8.5 GHz (with bias-tees, opt.xx5) E5072A 30 k to 4.5 / 8.5 GHz (with bias-tees) (Settable down to 9 khz) Yes (Option 014) No Yes (standard) +10 dbm (Option 014) +20 dbm (Option 011) -85 to +10 dbm (Standard) -85 to +8 dbm (Option 014) +10 dbm (up to 5 GHz) -55 to +10 dbm +16 dbm (spec, up to 3 GHz) +20 dbm (SPD, 300 k to 1 GHz) -85 to +16 dbm (spec, up to 3 GHz) -109 to +20 dbm (settable) Dynamic range (IFBW = 10 Hz) 110 db (16 M to 3 GHz) 123 db spec, 130 db SPD (10 M to 6 GHz) 123 db spec,130 db SPD (10 M to 6 GHz) Extended dynamic range (IFBW = 10 Hz) N/A N/A 151 db (SPD, 10 M to 3 GHz) IFBW 10 Hz to 6 khz 10 Hz to 500 khz 10 Hz to 500 khz Cycle Time (Full 2-port Cal, 1601 pt, 1 to 1.2 GHz) 836 ms (IFBW = 6 khz) 43 ms (IFBW = 500 khz) 33 ms (IFBW = 500 khz) Bias tee current 200 ma (spec) 200 ma (spec) 300 ma (spec) 1 A (damage level) 500 ma (damage level) 1 A (damage level) Receiver leveling No No Yes Software Options Time domain, FOM Time domain analysis, FOM, Time Domain, FOM Upgradability No Enhanced time domain analysis Yes (among all options) Note: SPD or Supplemental Performance Data represents the value that is most likely occurs. Not guaranteed by the product warranty. Yes (among all options) E5072A combines 8753ES & E5071C and so much more.

Comparison Chart of the ENA Series Advantages Features / Functions Configurable test set (Direct receiver access) Uncoupled Power (with source attenuators) Max Output Power Power Calibration Receiver Calibration E5071C 2-port RF Options (opt.24x, 26x, 28x) No No +10 dbm (up to 5 GHz) Yes Yes E5072A Yes (standard) Yes +16 dbm (spec, up to 3 GHz) +20 dbm (SPD, 300 k to 1 GHz) Yes (Most accurate with tolerance and max iteration) Yes (with four independent receivers) Receiver Leveling No Yes Harmonic distortion Yes (with FOM option) Yes (with FOM option) Pulsed-RF Yes (wide pulse width) Yes (wide pulse width) Amplifier measurement wizard Yes Yes (High-power measurement is also supported.) Equation Editor Yes Yes Note: SPD or Supplemental Performance Data represents the value that is most likely occurs. Not guaranteed by the product warranty.

E5072A Power Handling Capability As high power levels can damage the instrument and it is costly to repair, it is important to understand the power handling capability of each component in the VNA s signal path. Ex.) E5072A port performance Connector RF Damage Level (Typ.) DC Damage Level (Typ.) 0.1 db Compression Level (SPD*) Test Port 1 & 2 +26 dbm +-35 VDC +6 dbm (30 k to 300 khz) +16 dbm (300 k to 2 GHz) +14 dbm (2 G to 6 GHz) +10 dbm (6 G to 8.5 GHz) CPLR ARM +15 dbm 0 VDC - RCVR A IN, RCVR B IN SOURCE OUT (Port 1 & 2) CPLR THRU (Port 1 & 2) REF 1/2 SOURCE OUT RCVR R1 IN, RCVR R2 IN +15 dbm +-16 VDC -15 dbm (30 k to 300 khz) -10 dbm (300 k to 8.5 GHz) +26 dbm 0 VDC - +26 dbm +-35 VDC - +15 dbm 0 VDC - +15 dbm +-16 VDC -15 dbm (30 k to 300 khz) -10 dbm (300 k to 8.5 GHz) * SPD or supplemental performance data represents the value of a parameter that is most likely to occur, not guaranteed bay the product warranty.