LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic overload relay EF65, EF96 and EF146

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Electronic overload relay EF19 and EF45

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

RM4TG20 three-phase network control relay RM4-T - range V

Technical catalogue. Modular DIN rail components Installation contactors

Type: DILM50(230V50HZ,240V60HZ) Article No.:

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

Type: DILM32 10(24V50HZ) Article No.:

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

PSR The compact range Description

Manual motor starter MS116

Bimetallic Overload Relay Specifications

Catalog. Modular DIN rail components Installation contactors

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: DILM9 10(24VDC) Article No.:

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Bulletin 150 SMC Flex Smart Motor Controller Specifications

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Three-phase monitoring relay CM-PFE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Technicaldata General

38 Series - Relay interface modules A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Safety automation solutions

38 Series - Relay interface modules A

49 Series - Relay interface modules A. Features

Thermistor motor protection

Relés e Contatores de Estado Sólido SIRIUS

Catalog January. Heavy industrial power applications Motor contactors and starters

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

How To Protect A Motor From Overcurrent

Power Supplies 3. SDN-P DIN Rail Series

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

MasterINTERFACE 39 Series - Relay interface modules

Phone: Fax: Web: info@clrwtr.com

Safety detection solutions

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

R.C.C.B. s two-pole LEXIC

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Solid State Timers Type F

MasterINTERFACE 39 Series - Relay interface modules

Bulletin 1489 Circuit Breakers. Selection Guide

Safety technique. Emergency stop module BO 5988 safemaster

40 Series - Miniature PCB/Plug-in relays A. Features

Telemecanique Zelio Relay complementary and easy to assemble

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Switching Devices Contactors and Contactor Assemblies Special Applications

Circuit Breakers. NRC Series. NRC Series

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

80 Series - Modular timers 16 A. Features

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Manual Motor Starter MS 116 up to 16 A Technical Data

RY2 miniature industrial relays

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Tmax MCCBs. Molded case circuit breakers. Tmax

Circuit Breakers. Next Generation of Protection Capabilities

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Pluggable interface relays CR-P Pcb relays

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

Relays and Timers Specifications Bulletin Number 700

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

BETA Protecting SITOR Semiconductor Fuses

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SURGE PROTECTIVE DEVICES

Voltage Regulator SPAU 341 C. Product Guide

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Vario-Series Accessories

CompactLogix Power Supplies Specifications

Series 8146/5-V37 and Series 8150/5-V37

60 Series - General purpose relays 6-10 A. Features

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Redundancy Module QUINT-DIODE/40

3753 en /b VE/B - VE/RG Va V riable speed drives

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Control relays RH plug-in relays

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Transcription:

D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information............................................... - 3 Mini-Contactors Characteristics.................................................. - Selection...................................................... - 35 Auxiliary Contacts, Timers and Accessories........................... 36-5 Replacement Coils.............................................. 53-60 Dimensions and Mounting........................................ 6-66 Schematics.................................................... 67-69 Overload Relays Characteristics................................................. 70-75 Selection...................................................... 76-79 Dimensions, Mounting, and Schematics.............................. 80-8 Low Consumption DC Coil Mini-Contactors Characteristics................................................. 85-89 Selection...................................................... 90-93 Auxiliary Contacts, Timers, and Accessories.......................... 9-96 Dimensions and Mounting............................................97 Schematics........................................................98 Capacitor Switching Contactors..................................99-03 Plate-Mounted Starters.........................................0-05 Wye-Delta Starters........................................... 06 - Enclosed Contactors and Starters Horsepower Rated Devices for North American Applications....... - 9 Kilowatt Rated Devices for International Applications............. 0 - Definitions and Comments.........................................

D-Line Contactors, Overload Relays and Accessories General Information Introduction The Telemecanique family of IEC style contactors and starters are the largest selling motor control devices in the world. When the application calls for world class products, select the Telemecanique IEC style contactors and starters for products that are marketed and sold in over 60 countries. Most devices are UL listed, CSA certified, CE marked, meet IEC 97 standards and are approved by most other international approved agencies. The Telemecanique family of IEC style contactors and starters include the following: K-Line mini-contactors and overload relays are for general purpose starting and protection in a small package for loads up to Amps or resistive loads up to 0 Amps. D-Line contactors and overload relays offer the largest offering of accessories for maximum flexibility in customer applications and automated systems up to 50 motor full-load Amps or 00 Amp resistive loads. F-Line contactors and solid state overload relays are for inductive loads up to 800 Amps or resistive loads up to 350 Amps and share common accessories with the D-Line. GV manual starters provide manual isolation, manual motor control and overcurrent protection in one compact unit. They are approved for Group Motor Installations when used alone or with D-Line contactors. Integral self-protected starters combine all the functions of a disconnect switch, circuit breaker, contactor and overload relay in one coordinated unit to reduce required panel space by as much as 60% and reduce installation and wiring time. Selection of Telemecanique K-Line, D-Line and F-Line contactors are based on Utilization Categories, a combination of application and duty cycle rates defined by the following: The type of application (inductive motor loads or resistive loads) The conditions under which making or breaking current takes place (motor starting or running, reversing, plugging or jogging, locked rotor or stalled motor) Number of making and breaking operations (or cycles) required for the life of the contactor When specifying Telemecanique IEC contactors and starters refer to the following Square D documents: Catalog No. 850CT980 Catalog No. 850CT9703 Catalog No. 850CT970 Catalog No. 850CT970 Catalog No. 50CT950 Catalog No. 8539CT90 IEC Contactors Selection Guide K-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories F-Line Contactors, Overload Relays and Accessories GV/GV3 Manual Starters and AK5 Panel Busbar System Integral Self-Protected Starters 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories General Information The D-Line Contactors and Overload Relays are the largest selling line of contactors and starters in the world. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry. Contactor ratings D-Line contactors and overload relays are available in eleven contactor ratings for the USA market for inductive motor applications up to 50 full load Amps and resistive loads up to 00 Amps. They offer motor control and overload protection for motors rated up to 00 horsepower at 80 VAC or 5 horsepower at 600 VAC. 3-pole and -pole contactor versions available. Most contactors include built-in auxiliary contacts. All screw connections have IP0 rated Finger-safe terminals with both North American and International terminal markings. D-Line contactors can be panel mounted with screws or DIN rail mounted. Available in 3-pole contactor versions with built-in auxiliary contact for holding circuit or -pole contactor versions Easily installed Accessories Auxiliary contact blocks with serrated wiping action Front mount dust tight auxiliary contact blocks Pneumatic time delay blocks Transient voltage surge suppressors Interface modules and electronic timers Mechanical latching blocks Control circuit flexibility The D-Line contactors are available with AC or DC operating coils. Several devices utilize a low consumption DC coil with built-in transient suppression for operation with a low level DC signal from a computer or PLC without need for an interposing relay. Overload relays Class 0 or Class 0 bimetallic overload relays are available up to 0 Amps. They are ambient compensated and are available with or without single phase sensitivity for phase unbalance and phase loss protection. New solid state overload relays are available for 90 to 50 Amp applications. Both bimetallic and solid-state overload relays include the following features: isolated N.C. trip contact and N.O. alarm contacts, Manual or Automatic reset function, tamper resistant window for FLA settings and Test trip button. 7/98 998 Square D All Rights Reserved 3

D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Type Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to standards LC-D09 LC-D LC-D8 LC-D5 LP-D09 LP-D LP-D8 LP-D5 UL/CSA V 690 690 690 690 To IEC 97--, overvoltage category III, degree of pollution: 3 V 000 000 000 000 Conforming to UL, CSA V 600 600 600 600 Conforming to IEC 97 kv 8 8 8 8 Meets the essential requirements of the LV & EMC directives IEC 97-, 97--, NFC 63-0, VDE 0660, BS 5, JEM 038., EN 6097-, EN 6097--. Approvals E686 CCN NLDX LR336 Class 3 0 ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI, Conforming to SNCF, Sichere Trennung recommendations Power connections Protection against direct finger contact IP X Degree of protection c Conforming to VDE 006 Coil connections Protection against direct finger contact IP X Protective treatment Conforming to IEC 68 TH Storage - 60 to + 80 C (-76 to +76 F) Ambient air temperature around the Operation at 80 to 0% nominal control voltage device - 5 to + 55 C (-3 to +3 F) Permissible at nominal control voltage - 0 to + 70 C (-0 to +58 F) Maximum operating altitude Without derating 3000m (8900 ft) Operating positions Without derating ± 30 possible, in relation to normal vertical mounting plane Flame resistance Shock resistance a / sine wave = ms Vibration resistance a 5 to 300 Hz Pole characteristics Conforming to UL 9 V V V V Conforming to IEC 695-- 960 960 960 960 Contactor open 0 g 0 g 0 g 8 g Contactor closed 5 g 5 g 5 g 5 g Contactor open g g g g Contactor closed g g g g Number of poles 3 3 or 3 3 or In AC-3, θ 55 C (3 F) A 9 8 5 Rated operational current (Ie) In AC-, θ 0 C (0 F) A 0 5 3 0 Rated operational voltage (Ue) Up to V 690 690 690 690 Frequency limits Of the operational current Hz 5 to 00 5 to 00 5 to 00 5 to 00 Rated thermal current (Ith) θ 0 C (0 F) A 0 5 3 0 Rated making capacity ( rms) Conforming to IEC 97- A 50 50 300 50 Rated breaking capacity ( rms) Conforming to IEC 97 Permissible short time rating from cold state, no current flowing for previous 5 minutes, at θ 0 C c Protection provided for the cable c.s.a. indicated on pages 0 and and for cable connections. a In the least favorable direction, without change of contact state (coil supplied at Ue). 0-380-5-0 V 50 50 300 50 500 V A 75 75 50 00 690 V 85 85 0 80 For s A 0 0 0 380 For 0 s A 05 05 5 0 For min A 6 6 8 0 For 0 min A 30 30 0 50 By circuit breaker Select circuit breaker in accordance with NEC and local codes Short-circuit protection By fuses Maximum 00% of motor full load Amps Average impedance per pole A Ith and 50 Hz mω.5.5.5 Power dissipation per pole for the AC-3 W 0.0 0.36 0.8.5 above operational currents AC- W.56.56.5 3. 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Characteristics LC-D3 LC-D38 LC-D0 LC-D50 LC-D65 LC-D80 LC-D95 LC-D5 LC-D50 LP-D3 LP-D0 LP-D50 LP-D65 LP-D80 690 690 690 690 690 690 690 690 690 000 000 000 000 000 000 000 000 000 600 600 600 600 600 600 600 600 600 8 8 8 8 8 8 8 8 8 IEC 97-, 97--, NFC 63-0, VDE 0660, BS 5, JEM 038., EN 6097-, EN 6097--. ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI, Conforming to SNCF, Sichere Trennung UL, CSA recommendations Protection against direct finger contact IP X Protection against direct finger contact IP X except LP-D0 to D80 TH - 60 to + 80 C (-76 to +76 F) - 5 to + 55 C (-3 to +3 F) - 0 to + 70 C (-0 to +58 F) 3000m (8900 ft) ± 30 possible, in relation to normal vertical mounting plane V V V V V V V V V 960 960 960 960 960 960 960 960 960 8 g 8 g 8 g 8 g 8 g 8 g 8 g 6 g 6 g 5 g 0 g 0 g 0 g 0 g 0 g 0 g 5 g 5 g g g g g g g g g g g g 3 g 3 g 3 g 3 g 3 g g g 3 3 3 or 3 3 or 3 or 3 3 or 3 3 38 0 50 65 80 95 5 50 50 50 60 80 80 5 5 00 00 690 690 000 000 000 000 000 000 000 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 5 to 00 50 50 60 80 80 5 5 00 00 550 800 900 000 00 550 800 900 000 00 50 800 900 000 00 80 00 00 630 60 30 30 70 80 900 990 00 00 00 60 30 30 00 50 60 800 950 00 38 50 65 08 60 30 00 550 580 60 60 7 8 0 35 35 50 50 Select circuit breaker in accordance with NEC and local codes Maximum 00% of motor full load Amps.5.5 0.8 0.8 0.6 0.6. 3.7. 5. 7. 7.9 3.5 5 5 5. 9.6 6..5.5 7/98 998 Square D All Rights Reserved 5

D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Type LC-D09 LC-D LC-D8 LC-D5 Control circuit characteristics Rated control circuit voltage (Uc) 50 or 60 Hz V to 660 Control voltage limits (θ 55 C) 50 or 60 Hz coils 50/60 Hz coils Operational Drop-out Operational Drop-out 0.8 to. Uc 0.3 to 0.6 Uc 0.85 to. Uc at 60 Hz 0.3 to 0.6 Uc 50 Hz coil VA 60 60 60 90 Inrush Cos ϕ 0.75 0.75 0.75 0.75 50/60 Hz coil VA 70 70 70 0 50 Hz AC 50 Hz coil VA 7 7 7 7.5 Sealed Cos ϕ 0.3 0.3 0.3 0.3 50/60 Hz coil VA 8 8 8 8.5 Average consumption at 0 C and at Uc 60 Hz coil VA 70 70 70 00 Inrush Cos ϕ 0.75 0.75 0.75 0.75 50/60 Hz coil VA 70 70 70 00 60 Hz AC 60 Hz coil VA 7.5 7.5 7.5 8.5 Sealed Cos ϕ 0.3 0.3 0.3 0.3 50/60 Hz coil VA 8 8 8 8.5 Heat dissipation 50/60 Hz W to 3 to 3 to 3.5 to 3.5 Operating time c Mechanical durability in millions of operating cycles Maximum operating rate at ambient temperature 55 C Closing C ms to to to 5 to Opening O ms to 9 to 9 to 9 5 to 9 50 or 60 Hz coil 0 0 6 6 50/60 Hz coil at 50 Hz 5 5 5 In operating cycles per hour 3600 3600 3600 3600 c The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the mains poles separate. 6 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Characteristics LC-D3 LC-D38 LC-D0 LC-D50 LC-D65 LC-D80 LC-D95 LC-D5 LC-D50 to 660 to 660 to 50 0.8 to. Uc 0.85 to. Uc 0.3 to 0.6 Uc 0.3 to 0.5 Uc 0.85 to. Uc at 60 Hz 0.8 to.5 Uc at 50/60 Hz 0.3 to 0.6 Uc 0.3 to 0.5 Uc 90 90 00 00 00 00 00 300 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.8 0.9 00 00 5 5 5 5 5 50 50 7.5 7.5 0 0 0 0 0 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.9 8.5 8.5 6 6 6 6 6 6 6 00 00 0 0 0 0 0 300 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.8 0.9 00 00 5 5 5 5 5 50 50 8.5 8.5 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.9 8.5 8.5 6 6 6 6 6 6 6.5 to 3.5.5 to 3.5 6 to 0 6 to 0 6 to 0 6 to 0 6 to 0 7 to 8 6 to 7 5 to 5 to 0 to 6 0 to 6 0 to 6 0 to 35 0 to 35 0 to 50 5 to 35 5 to 9 5 to 9 8 to 8 to 8 to 6 to 0 6 to 0 6 to 0 0 to 55 6 6 6 6 6 0 0 8 6 6 6 8 8 3600 3600 3600 3600 3600 3600 3600 00 00 7/98 998 Square D All Rights Reserved 7

D-Line Contactors, Overload Relays and Accessories Characteristics Type LP-D09, D, D8 LP-D5, D3 LP-D0, D50, D65 LP-D80 Control circuit characteristics LC-D5 LC-D50 Rated control circuit voltage (Uc) DC V to 0 to 0 to 0 Control voltage limits (θ 55 C) Average consumption at 0 C and at Uc Standard coil 0.8 to. Uc 0.85 to. Uc 0.7 to. Uc Operational Wide range coil 0.7 to.5 Uc 0.75 to. Uc Drop-out 0. to 0.5 Uc 0. to 0.3 Uc 0. to 0. Uc DC Inrush W 9 6 Sealed W 9 6 Closing C ms 0 to 8 5 to 6 85 to 0 95 to 30 5 to 35 Operating time c average at Uc Opening O ms 6 to 8 to 0 to 35 0 to 35 0 to 35 Note: the arcing time depends on the circuit switched by the poles. For normal three-phase applications, arcing time is normally less than 0 ms. The load is isolated from the supply after a time equal to the sum of the opening time and the arcing time. Mechanical durability at Uc In millions of operating cycles 30 5 0 0 8 Maximum operating rate at ambient temperature 55 C In operating cycles per hour 3600 3600 3600 3600 00 c The operating times depend on the type of contactor electromagnet and its control mode. The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the mains poles separate. 8 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Integrated auxiliary contacts Rated operational voltage (Ue) Up to V 690 Conforming to IEC 97- V 000 Rated insulation voltage (Ui) Conforming to UL, CSA V 600 Rated thermal current (Ith) For ambient temperature 0 C (0 F) A 0 Frequency of operational current Hz 5 to 00 U min (minimum voltage) V 7 Minimum switching capacity I min (minimum current) ma 5 Short-circuit protection Conforming to IEC 97-5- gg fuse: 0 A Rated making capacity Conforming to IEC 97-5-, I rms A 0 AC, 50 DC s A 00 Short time rating Permissible for 500 ms A 0 00 ms A 0 Insulation resistance MΩ > 0 Non-overlap time Guaranteed between N.C. and N.O. contacts ms.5 on energization and on de-energization Operational power of contacts conforming to IEC 97-5- AC supply categories AC- and AC-5 Electrical durability (up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making power (cos ϕ 0.7) = 0 times the power broken (cos ϕ 0.). DC supply category DC-3 Electrical life (up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V 8 0/ 7 0/30 380/00 0 600 V 8 0 0 0 600 million operating cycles VA 50 300 00 80 500 500 500 W 0 90 75 68 6 58 3 million operating cycles VA 80 70 50 90 30 30 30 W 70 50 38 33 8 7 0 million operating cycles VA 30 65 90 0 30 30 30 W 5 8 0 9 Occasional making capacity VA 00 600 7000 3 000 5 000 3 000 9000 W 000 700 00 60 0 70 Breaking limit of contacts for: maximum of 50 operating cycles at 0 s intervals. (power broken = making power x cos 0.7). Electrical durability of contacts: - for million operating cycles (a). - for 3 million operating cycles (b). - for 0 million operating cycles (c). 3 Breaking limit of contacts for: maximum of 0 operating cycles at 0 s intervals and with current passing for 0.5 s per cycle. Thermal limit. Power broken in VA 6 000 0 000 8000 6000 5000 000 3000 000 000 800 600 500 00 300 00 00 80 60 0 a b c 8 0 0 0 380 500 0 690 V Power broken in VA 50 00 0 00 50 0 000 700 500 300 00 00 80 60 50 0 30 0 0 8 6 3 a b c 8 0 0 0 600 V 7/98 998 Square D All Rights Reserved 9

D-Line Contactors, Overload Relays and Accessories Characteristics Type LCkD and LPkD contactors Power and control circuit connections Type Power circuit connections Cabling Bus bar connection Control circuit connections Cabling Stranded cable without cable end Flexible cable with cable end Connector type LC-D09 LP-D09 Screw clamp terminals LC-D LP-D LC-D8 LP-D8 LC-D5 LP-D5 conductor AWG 8-0 8-0 8-8 8-8 conductors AWG 8-0 8-0 8-8 8-8 conductor mm / /.5/6.5/0 conductors mm / /.5/6.5/6 conductor AWG 8-6 8-6 8-3 8-3 conductors AWG 8-0 8-0 8-6 8-3 conductor mm / / /6 /6 conductors mm /.5 /.5 / / conductor AWG 8-8 8-8 8-8 8-8 conductors AWG 8-8 8-8 8-8 8-8 Solid cable without cable end conductor mm / /.5/6.5/6 conductors mm / /.5/6.5/6 Phillips head type N N N N Screwdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Hexagon spanner Tightening torque 7 lb.-in.. Nkm 7 lb.-in.. Nkm 5 lb.-in..7 Nkm Connection by bus bar or ring tongue terminals Bar c.s.a. Lug external Ø mm 8 8 8 0 Screw Ø mm M3.5 M3.5 M3.5 M Phillips head type N N N N Screwdriver Ø Ø 6 Ø 6 Ø 6 Ø 6 Hexagon spanner Tightening torque Stranded cable without cable end Stranded cable with cable end 7 lb.-in.. Nkm Connection by cable Screw clamp terminals 7 lb.-in.. Nkm 5 lb.-in..7 Nkm 5 lb.-in..85 Nkm 5 lb.-in..85 Nkm or conductors AWG 8-8- 8-8- conductor mm / / / / conductors mm / / / / conductor mm / / / / conductors mm /.5 /.5 /.5 /.5 conductor mm / / / / Solid cable without cable end conductors mm / / / / Phillips head type N N N N Screwdriver Ø mm Ø 6 Ø 6 Ø 6 Ø 6 Tightening torque 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm Connection by bus bar or ring tongue terminals Lug external Ø mm 8 8 8 8 Screw Ø mm M3.5 M3.5 M3.5 M3.5 Phillips head type N N N N Screwdriver Ø Tightening torque 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 7 lb.-in.. Nkm 3/6 in. Ø 6 7 lb.-in.. 0 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Characteristics LC-D3 LP-D3 LC-D38 LC-D0 LP-D0 LC-D50 LP-D50 LC-D65 LP-D65 LC-D80 LP-D80 LC-D95 LC-D5 LC-D50 Box lug terminals LA9D560 terminals -6 0-3 0-3 0-3 0-8-50 mcm 8-50 mcm -6 0-0- 0-0- 8-0+8-50 mcm 8-0+8-50 mcm.5/0.5/0.5/5.5/5.5/5 /50 /50 0/0 0/0.5/0.5/0.5/6.5/6.5/6 /5 /5 0/0+ 0/50 0/0+ 0/50 8-3/0 0-0- 0-0- - - - - - /0 /0.5/5.5/5.5/5 /50 /50 0/0 0/0.5/6.5/6.5/0.5/0.5/0 /6 /6 0/0+ 0/50 0/0+ 0/50-8 0-3 0-3 0-3 0-3 8-50 mcm 8-50 mcm 0-8 8-0+ 8-50mcm 8-0+8-50 mcm.5/0.5/0.5/5.5/5.5/5 /50 /50 0/0 0/0.5/0.5/0.5/6.5/6.5/6 /5 /5 0/0+ 0/50 0/0+ 0/50 N N Ø 6 Ø 6 Ø 6 to Ø 8 Ø 6 to Ø 8 Ø 6 to Ø 8 Ø 6 to Ø 8 Ø 6 to Ø 8 mm mm mm mm mm mm mm 0 lb.-in..5 Nkm.5 Nkm 5 lb.-in. 5 Nkm 5 lb.-in. 5 Nkm 5 lb.-in. 5 Nkm 00 lb.-in. 9 Nkm 9 Nkm 00 lb. in. Nkm Connection by bus bar or ring tongue terminals 3 x 6 3 x 6 5 x 5 5 x 5 0 0 3 6 6 7 7 5 5 M M M5 M6 M6 M6 M6 M8 M8 N N 3/6 in. Ø 6 mm 3/6 in. Ø 6 mm 0 mm 0 mm 3 mm 3 mm.5.5 6 8 8 8 8 00 lb. in. Nkm Connection by cable Screw clamp terminals 8-8- 8-8- 8-8- 8-8- 8- / / / / / / / /.5 /.5 / / / / / / / /.5 /.5 / / / / / / / /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 /.5 / / / / / / / /.5 /.5 / / / / / / / /.5 /.5 N N N N N N N N N Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 Ø 6 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm 7 lb.-in.. Nkm Connection by bus bar or ring tongue terminals 8 8 8 8 8 8 8 8 8 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 M3.5 N N N N N N N N N 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 3/6 in. Ø 6 7 lb.-in.. 7 lb.-in.. Nkm 3/6 in. Ø 6 7 lb.-in.. 7/98 998 Square D All Rights Reserved

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications 3-pole contactors with Fingersafe terminals for power cabling LC-D090kk LC-D50kk LC-D95kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operating current in AC-3 0V up to Instantaneous auxiliary contacts * Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 3 5.5 5.5 5.5 7.5 7.5 7.5 9 9 0 0 8 5.5 5 5 5 7.5 5 5 5 8.5 8.5 3 Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. Weight LC-D0900kk 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D00kk 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D800kk 0.355 (0.79) LC-D80kk q 0.365 (0.8) LC-D80kk q 0.365 (0.8) LC-D500kk 0.00 (0.89) LC-D50kk q 0.530 (.8) LC-D50kk q 0.530 (.8) LC-D300kk 0.55 (.) LC-D30kk q 0.555 (.) LC-D30kk q 0.555(.3) LC-D380kk 0.555 (.3) 9 8.5 8.5 8.5 8.5 8.5 38 LC-D380kk 0.555 (.3) 8.5 30 0 LC-D0kk q.00 (3.) 5 5 30 30 33 30 50 LC-D50kk.00 (3.) 8.5 30 37 37 37 37 37 65 LC-D65kk.00 (3.) 37 5 5 55 5 5 80 LC-D80kk.590 (3.53) 5 5 5 5 55 5 5 95 LC-D95kk.60 (3.58) 30 55 59 59 75 80 75 5 LC-D500kk.0 (5.38) 0 75 80 80 90 00 90 50 LC-D5000kk.0 (5.) aac Coil Selection Volts 8 0 0 08 0 30 0 77 380 00 5 0 80 500 575 600 660 LC-D09 to D95 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 X5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 S7 Other voltages from to 660 V, see pages 53 to 56. LC-D500kk 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Horsepower ratings for North American applications 3-pole contactors with Fingersafe terminals for power cabling LC-D090kk LC-D50kk LC-D95kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting hp hp hp hp hp hp A N/O N/C kg (lb.) 0.5 5 7.5 9 3 3 7.5 0 3 5 5 0 5 8 3 7.5 7.5 5 0 5 5 0 0 0 30 3 Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. Weight LC-D0900kk 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D090kk q 0.30 (0.75) LC-D00kk 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D0kk q 0.35 (0.77) LC-D800kk 0.355 (0.79) LC-D80kk q 0.365 (0.8) LC-D80kk q 0.365 (0.8) LC-D500kk 0.00 (0.89) LC-D50kk q 0.530 (.8) LC-D50kk q 0.530 (.8) LC-D300kk 0.55 (.) LC-D30kk q 0.555 (.) LC-D30kk q 0.555(.3) Not UL listed or CSA certified LC-D380kk 0.555 (.3) 38 Not for North American applications LC-D380kk 0.555 (.3) 3 5 0 0 30 30 0 LC-D0kk q.00 (3.) 3 7.5 5 5 0 0 50 LC-D50kk.00 (3.) 5 0 0 0 50 50 65 LC-D65kk.00 (3.) 7.5 5 5 30 60 60 80 LC-D80kk.590 (3.53) Not UL listed or CSA certified Not for North American applications 95 LC-D95kk.60 (3.58) 30 0 75 00 5 LC-D500kk.0 (5.38) 0 50 00 5 50 LC-D5000kk.0 (5.) aac Coil Selection Volts 8 0 0 08 0 30 0 77 380 00 5 0 80 500 575 600 660 LC-D09 to D95 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 X5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 S7 Other voltages from to 660 V, see pages 53 to 56. LC-D500kk 7/98 998 Square D All Rights Reserved 3

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications 3-pole contactors for ring-tongue terminals or bus bar power connections LC-D5006kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operating current in AC-3 0V up to Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 3 5.5 5.5 5.5 7.5 7.5 7.5 9 9 0 0 8 5.5 5 5 5 7.5 5 5 5 8.5 8.5 3 Weight LC-D09006kk 0.335 (0.7) LC-D0906kk 0.335 (0.7) LC-D0906kk 0.335 (0.7) LC-D006kk 0.335 (0.7) LC-D06kk 0.335 (0.7) LC-D06kk 0.335 (0.7) LC-D8006kk 0.35 (0.77) LC-D806kk 0.35 (0.78) LC-D806kk 0.35 (0.78) LC-D5006kk 0.390 (0.87) LC-D506kk 0.50 (.5) LC-D506kk 0.50 (.5) LC-D3006kk 0.535 (.8) LC-D306kk 0.55 (.) LC-D306kk 0.55 (.) LC-D3806kk 0.55 (.) 9 8.5 8.5 8.5 8.5 8.5 38 LC-D3806kk 0.55 (.) 8.5 30 0 LC-D06kk.30 (.93) 5 5 30 30 33 30 50 LC-D506kk.30 (.93) 8.5 30 37 37 37 37 37 65 LC-D656kk.30 (.93) 37 5 5 55 5 5 80 LC-D806kk.600 (3.55) 5 5 5 5 55 5 5 95 LC-D956kk.600 (3.55) 30 55 59 59 75 80 75 5 LC-D5006kk.0 (.69) 0 75 80 80 90 00 90 50 LC-D50006kk.30 (.69) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page. 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: AC Horsepower ratings for North American applications 3-pole contactors for ring-tongue terminals or bus bar power connections LC-D5006kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting hp hp hp hp hp hp A N/O N/C kg (lb.) 0.5 5 7.5 9 3 3 7.5 0 3 5 5 0 5 8 3 7.5 7.5 5 0 5 5 0 0 0 30 3 Weight LC-D09006kk 0.335 (0.7) LC-D0906kk 0.335 (0.7) LC-D0906kk 0.335 (0.7) LC-D006kk 0.335 (0.7) LC-D06kk 0.335 (0.7) LC-D06kk 0.335 (0.7) LC-D8006kk 0.35 (0.77) LC-D806kk 0.35 (0.78) LC-D806kk 0.35 (0.78) LC-D5006kk 0.390 (0.87) LC-D506kk 0.50 (.5) LC-D506kk 0.50 (.5) LC-D3006kk 0.535 (.8) LC-D306kk 0.55 (.) LC-D306kk 0.55 (.) Not UL listed or CSA certified LC-D3806kk 0.55 (.) 38 Not for North American applications LC-D3806kk 0.55 (.) 3 5 0 0 30 30 0 LC-D06kk.30 (.93) 3 7.5 5 5 0 0 50 LC-D506kk.30 (.93) 5 0 0 0 50 50 65 LC-D656kk.30 (.93) 7.5 5 5 30 60 60 80 LC-D806kk.600 (3.55) Not UL listed or CSA certified Not for North American applications 95 LC-D956kk.600 (3.55) 30 0 75 00 5 LC-D5006kk.0 (.69) 0 50 00 5 50 LC-D50006kk.30 (.69) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page 3. 7/98 998 Square D All Rights Reserved 5

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole contactors with Finger-safe terminals for power cabling LC-D090kk LC-D50kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operat. current in AC-3 0V up to Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 3 5.5 5.5 5.5 7.5 7.5 7.5 9 9 0 0 8 5.5 5 5 5 Weight LP-D090kk 0.60 (.) LP-D090kk 0.60 (.) LP-D0kk 0.60 (.) LP-D0kk 0.60 (.) LP-D80kk 0.650 (.) LP-D80kk 0.650 (.) LP-D50kk 0.95 (.05) LP-D50kk 0.95 (.05) LP-D30kk 0.950 (.) 7.5 5 5 5 8.5 8.5 3 LP-D30kk 0.950 (.) 8.5 30 0 LP-D0kk.85 (.85) 5 5 30 30 33 30 50 LP-D50kk.85 (.85) 8.5 30 37 37 37 37 37 65 LP-D65kk.90 (.87) 37 5 5 55 5 5 80 LP-D80kk.55 (5.6) 30 55 59 59 75 80 75 5 LC-D500kk.0 (5.) 0 75 80 80 90 00 90 50 LC-D5000kk.0 (5.) Note: Auxiliary contact blocks and modules: see pages to 9. c For LP-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LP-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Volts 36 8 60 7 0 5 0 50 0 LP-D09 to D3 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD LC-D65kk U 0.7 to.5 Uc JW BW CW EW SW FW MW U 0.7 to.5 Uc JW BW CW EW SW FW MW LP-D0 to D80 U 0.85 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75 to. Uc JW BW CW EW SW FW MW LC-D5 and D50 (coils with built-in surge suppression) U 0.7 to. Uc BD ED ND SD FD GD MD UD RD Other voltages from to 0 V, see pages 57 to 60. LC-D500kk 6 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Horsepower ratings for North American applications 3-pole contactors with Finger-safe terminals for power cabling LC-D090kk LC-D50kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting hp hp hp hp hp hp A N/O N/C kg (lb.) 0.5 5 7.5 9 3 3 7.5 0 3 5 5 0 5 8 3 7.5 7.5 5 0 5 Weight LP-D090kk 0.60 (.) LP-D090kk 0.60 (.) LP-D0kk 0.60 (.) LP-D0kk 0.60 (.) LP-D80kk 0.650 (.) LP-D80kk 0.650 (.) LP-D50kk 0.95 (.05) LP-D50kk 0.95 (.05) LP-D30kk 0.950 (.) 5 0 0 0 30 3 LP-D30kk 0.950 (.) 3 5 0 0 30 30 0 LP-D0kk.85 (.85) 3 7.5 5 5 0 0 50 LP-D50kk.85 (.85) 5 0 0 0 50 50 65 LP-D65kk.90 (.87) 7.5 5 5 30 60 60 80 LP-D80kk.55 (5.6) 30 0 75 00 5 LC-D500kk.0 (5.) 0 50 00 5 50 LC-D5000kk.0 (5.) Note: Auxiliary contact blocks and modules: see pages to 9. c For LP-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LP-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Volts 36 8 60 7 0 5 0 50 0 LP-D09 to D3 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD LC-D65kk U 0.7 to.5 Uc JW BW CW EW SW FW MW U 0.7 to.5 Uc JW BW CW EW SW FW MW LP-D0 to D80 U 0.85 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75 to. Uc JW BW CW EW SW FW MW LC-D5 and D50 (coils with built-in surge suppression) U 0.7 to. Uc BD ED ND SD FD GD MD UD RD Other voltages from to 0 V, see pages 57 to 60. LC-D500kk 7/98 998 Square D All Rights Reserved 7

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole contactors for ring-torque terminals or bus bar power connections LC-D5006kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operat. current in AC-3 0V up to Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting 000V kw kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 3 5.5 5.5 5.5 7.5 7.5 7.5 9 9 0 0 8 5.5 5 5 5 Weight LP-D0906kk 0.630 (.0) LP-D0906kk 0.630 (.0) LP-D06kk 0.630 (.0) LP-D06kk 0.630 (.0) LP-D806kk 0.60 (.) LP-D806kk 0.60 (.) LP-D506kk 0.95 (.03) LP-D506kk 0.95 (.03) LP-D306kk 0.90 (.09) 7.5 5 5 5 8.5 8.5 3 LP-D306kk 0.90 (.09) 8.5 30 0 LP-D06kk.75 (.83) 5 5 30 30 33 30 50 LP-D506kk.75 (.83) 8.5 30 37 37 37 37 37 65 LP-D656kk.80 (.8) 37 5 5 55 5 5 80 LP-D806kk.55 (5.59) 30 55 59 59 75 80 75 5 LC-D5006kk.30 (.73) 0 75 80 80 90 00 90 50 LC-D50006kk.30 (.73) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page 6. 8 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Motor Control Control Circuit: DC Horsepower ratings for North American applications 3-pole contactors for ring-torque terminals or bus bar power connections Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz 5/ 0V 30/ 0V 00/ 08V 0/ 0V 60/ 80V 575V 600V Maximum inductive current in AC-3 category 600V Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting Weight hp hp hp hp hp hp A N/O N/C kg (lb.) LC-D5006kk LP-D0906kk 0.630 (.0) 0.5 5 7.5 9 LP-D0906kk 0.630 (.0) LP-D06kk 0.630 (.0) 3 3 7.5 0 LP-D06kk 0.630 (.0) LP-D806kk 0.60 (.) 3 5 5 0 5 8 LP-D806kk 0.60 (.) LP-D506kk 0.95 (.03) 3 7.5 7.5 5 0 5 LP-D506kk 0.95 (.03) LP-D306kk 0.90 (.09) 5 0 0 0 30 3 LP-D306kk 0.90 (.09) 3 5 0 0 30 30 0 LP-D06kk.75 (.83) 3 7.5 5 5 0 0 50 LP-D506kk.75 (.83) 5 0 0 0 50 50 65 LP-D656kk.80 (.8) 7.5 5 5 30 60 60 80 LP-D806kk.55 (5.59) 30 0 75 00 5 LC-D5006kk.30 (.73) 0 50 00 5 50 LC-D50006kk.30 (.73) 3-pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages see page 7. 7/98 998 Square D All Rights Reserved 9

D-Line Contactors, Overload Relays and Accessories Selection Resistive Loads Control circuit: AC 3 or -pole contactors with Fingersafe terminals for power cabling Non-inductive loads maximum current (θ 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight LC-D00kk LC-D6500kk LC-D500kk A N/O N/C N/O N/C kg (lb.) LC-D0900kk 0.30 (0.75) or LC-D00kk q 0.35 (0.77) LC-D090kk 0.30 (0.75) 3 or LC-D0kk q 0.35 (0.77) 5 LC-D090kk 0.30 (0.75) or LC-D0kk q 0.35 (0.77) LC-D00kk 0.350 (0.77) LC-D008kk 0.350 (0.77) LC-D800kk 0.355 (0.79) 3 3 LC-D80kk 0.365 (0.8) LC-D80kk 0.365 (0.8) LC-D500kk 0.00 (0.89) 3 LC-D50kk 0.530 (.8) 0 LC-D50kk 0.530 (.8) LC-D500kk 0.530 (.8) LC-D5008kk 0.535 (.9) LC-D300kk 0.55 (.) LC-D30kk 0.555 (.3) 50 3 or LC-D380kk LC-D30kk 0.555 (.3) or LC-D380kk 3 LC-D0kk.00 (3.) 60 LC-D000kk.0 (3.0) LC-D0008kk.50 (3.) LC-D50kk.00 (3.) 3 or LC-D65kk q.00 (3.) 80 LC-D6500kk.0 (3.0) LC-D65008kk.50 (3.) LC-D80kk.590 (3.53) 3 or LC-D95kk q.60 (3.58) 5 LC-D8000kk.760 (3.9) LC-D80008kk.80 (.09) LC-D500kk.0 (5.38) 3 00 LC-D5000kk q.0 (5.) or LC-D500kk.860 (6.35) Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages???? to?????. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. aac Coil Selection Volts 8 0 0 7 08 0 30 0 77 380 00 5 0 80 500 575 600 660 LC-D09 to D95 50 Hz B5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 S5 X5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 Other voltages from to 660 V, see pages 53 to 56. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT980. 0 998 Square D All Rights Reserved 7/98

Control Circuit: AC D-Line Contactors, Overload Relays and Accessories Selection Resistive Loads 3 or -pole contactors for ring tongue terminals or bus bar power connections Non-inductive loads maximum current (θ 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight LC-D5006kk A N/O N/C N/O N/C kg (lb.) LC-D09006kk 0.335 (0.7) or LC-D006kk q 0.335 (0.7) LC-D0906kk 0.335 (0.7) 3 or LC-D06kk q 0.335 (0.7) 5 LC-D0906kk 0.335 (0.7) or LC-D06kk q 0.335 (0.7) LC-D006kk 0.30 (0.75) LC-D0086kk 0.30 (0.75) LC-D8006kk 0.35 (0.77) 3 3 LC-D806kk 0.35 (0.78) LC-D806kk 0.35 (0.78) LC-D5006kk 0.390 (0.87) 3 LC-D506kk 0.50 (.5) 0 LC-D506kk 0.50 (.5) LC-D5006kk 0.50 (.5) LC-D50086kk 0.55 (.7) LC-D3006kk 0.535 (.9) LC-D306kk 0.55 (.) 50 3 or LC-D3806kk 0.55 (.) LC-D306kk 0.55 (.) or LC-D3806kk 0.55 (.) 3 LC-D06kk.30 (.93) 60 LC-D0006kk.30 (3.8) LC-D00086kk.0 (3.0) LC-D506kk.30 (.93) 3 or LC-D656kk q.30 (.93) 80 LC-D65006kk.30 (3.8) LC-D650086kk.0 (3.0) LC-D806kk.600 (3.55) 3 or LC-D956kk q.600 (3.55) 5 LC-D80006kk.750 (3.89) LC-D800086kk.830 (.07) LC-D5006kk.0 (.68) 3 00 or LC-D50006kk.30 (.73) LC-D5006kk q.50 (5.) 3 or -pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: 3-pole contactors without auxiliary contacts conform to standard EN 500. Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. For LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages: see page 0. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT980. 7/98 998 Square D All Rights Reserved

D-Line Contactors, Overload Relays and Accessories Selection Contactors for Resistive Loads Control Circuit: DC 3 or -pole contactors with Fingersafe terminals for power cabling Non-inductive loads maximum current (q 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight A N/O N/C N/O N/C kg (lb.) LC-D00kk LC-D6500kk LP-D090kk 0.60 (.) or LP-D0kk q 0.60 (.) 3 LP-D090kk 0.60 (.) 5 or LP-D0kk q 0.60 (.) LP-D00kk 0.60 (.) or LP-D008kk 0.60 (.) 3 3 3 0 LP-D80kk 0.650 (.) LP-D80kk 0.650 (.) LP-D50kk 0.95 (.05) LP-D50kk 0.95 (.05) LP-D500kk 0.930 (.07) LP-D5008kk 0.930 (.07) LP-D30kk 0.950 (.) 50 3 LP-D30kk 0.950 (.) 3 LP-D0kk.85 (.85) 60 LP-D000kk.05 (.90) LP-D0008kk.00 (.88) LP-D50kk.85 (.85) 3 or LP-D65kk q.90 (.86) 80 LP-D6500kk.0 (.9) LP-D65008kk.0 (.93) 3 LP-D80kk.55 (5.6) 5 LP-D8000kk.695 (5.99) LP-D80008kk.90 (6.7) LC-D500kk.0 (5.) 3 00 or LC-D5000kk q.0 (5.) LC-D500kk.900 (6.) Auxiliary contact blocks and modules: see pages???? to?????. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. For LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. LC-D500kk a DC Coil Selection Volts 36 8 60 7 0 5 0 50 0 LP-D09 to D3 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW LP-D0 to D80 U 0.85 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.75 to. Uc JW BW CW EW SW FW MW LC-D5 and D50 (coils with built-in surge suppression) U 0.7 to. Uc BD ED ND SD FD GD MD UD RD Other voltages from to 0 V, see pages 57 to 60. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT980. 998 Square D All Rights Reserved 7/98

Control Circuit: DC D-Line Contactors, Overload Relays and Accessories Selection Contactors for Resistive Loads 3 or -pole contactors for ring tongue terminals or bus bar power connections Non-inductive loads maximum current (θ 55 C) Utilization category AC- Number of poles Instantaneous auxiliary contacts Catalog number. Complete with code indicating control circuit voltage a. c DIN rail or screw mounting Weight LC-D5006kk A N/O N/C N/O N/C kg (lb.) LP-D0906kk 0.630 (.0) or LP-D06kk q 0.630 (.0) 3 LP-D0906kk 0.630 (.0) 5 or LPD06kk q 0.630 (.0) LP-D006kk 0.630 (.0) LP-D0086kk 0.630 (.0) 3 3 3 0 LP-D806kk 0.60 (.) LP-D806kk 0.60 (.) LP-D506kk 0.95 (.03) LP-D506kk 0.95 (.03) LP-D5006kk 0.90 (.0) LP-D50086kk 0.90 (.0) LP-D306kk 0.90 (.09) 50 3 LP-D306kk 0.90 (.09) 3 LP-D06kk.75 (.83) 60 LP-D0006kk.90 (.87) LP-D00086kk.90 (.87) LP-D506kk.75 (.83) 3 or LP-D656kk q.80 (.8) 80 LP-D65006kk.00 (.89) LP-D650086kk.0 (.9) 3 LP-D806kk.55 (5.59) 5 LP-D80006kk.680 (5.95) LP-D800086kk.900 (6.) LC-D5006kk.30 (.73) 3 00 or LC-D50006kk q.30 (.73) LC-D5006kk.70 (5.9) 3 or -pole contactors for connection with slip-on connectors For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Note: Auxiliary contact blocks and modules: see pages to 9. c For LC-D09 to D3: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. For LC-D0 to D80: clip-on mounting on 75 mm ( DIN rail AM-DL or screw mounting. For LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages, see page????. q Selection according to number of operating cycles, see AC- curve in IEC Contactors Selection Guide 850CT980. 7/98 998 Square D All Rights Reserved 3

D-Line Contactors, Overload Relays and Accessories Selection Reversing Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications, pre-assembled, horizontally mounted 3-pole reversing contactors with Fingersafe terminals for power cabling Includes pre-wired power connections q f Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3 Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c Weight LC-D0kk LC-D50kk 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V 000 V 0 V up to kw kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 3 5.5 5.5 5.5 7.5 7.5 7.5 9 9 0 0 8 5.5 5 5 5 LC-D090kk q 0.700 (.55) LC-D090kk f LC-D0kk q 0.700 (.55) LC-D0kk f LC-D80kk q 0.750 (.67) LC-D80kk f LC-D50kk q.00 (.) LC-D50kk f LC-D30kk q.00 (.67) 7.5 5 5 5 8.5 8.5 3 LC-D30kk f 9 8.5 8.5 8.5 8.5 8.5 38 LC-D380kk q.00 (.67) 8.5 30 0 LC-D0kk q.00 (5.33) 5 5 30 30 33 50 LC-D50kk q.00 (5.33) 8.5 30 37 37 37 37 65 LC-D65kk q.00 (5.33) 37 5 5 55 5 80 LC-D80kk q 3.00 (7.) 5 5 5 5 55 5 95 LC-D95kk q 3.00 (7.) 30 55 59 59 75 80 75 5 LC-D500kk f 6.500 (.) 0 75 80 80 90 00 90 50 LC-D5000kk f 6.600 (.) Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. aac Coil Selection Volts 8 0 0 7 08 0 30 0 77 380 00 5 0 80 500 575 600 660 LC-D09 to D95 50 Hz B5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0). 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Selection Reversing Contactors for Motor Control Control Circuit: AC Horsepower ratings for North American applications, 3-pole reversing contactors with Fingersafe terminals for power cabling Pre-wired power connections q f LC-D0kk LC-D50kk Maximum horsepower ratings Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c -phase 50/60 Hz 3-phase 50/60 Hz hp hp hp hp hp hp A N/O N/C kg (lb.) LC-D090kk q 0.700 (.55) 0.5 5 7.5 9 LC-D090kk f LC-D0kk q 0.700 (.55) 3 3 7.5 0 LC-D0kk f LC-D80kk q 0.750 (.67) 3 5 5 0 5 8 LC-D80kk f LC-D50kk q.00 (.) 3 7.5 7.5 5 0 5 LC-D50kk f LC-D30kk q.00 (.67) 5 0 0 0 30 3 LC-D30kk f Not UL listed or CSA certified Not for North American applications 38 LC-D380kk q.00 (.67) 3 5 0 0 30 30 0 LC-D0kk q.00 (5.33) 3 7.5 5 5 0 0 50 LC-D50kk q.00 (5.33) 5 0 0 0 50 50 65 LC-D65kk q.00 (5.33) 7.5 5 5 30 60 60 80 LC-D80kk q 3.00 (7.) Not UL listed or CSA certified Not for North American applications 95 LC-D95kk q 3.00 (7.) 30 0 75 00 5 LC-D500kk f 6.500 (.) 0 50 00 5 50 LC-D5000kk f 6.600 (.) Weight Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages???? to????. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D95: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. aac Coil Selection Volts 8 0 0 7 08 0 30 0 77 380 00 5 0 80 500 575 600 660 LC-D09 to D95 50 Hz B5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 LC-D09 to D50 (coils D5 and D50 with built-in surge suppression) 50/60 Hz B7 D7 E7 F7 FE7 M7 P7 U7 Q7 V7 N7 R7 T7 q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for switching contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0) and pre-wired for switching contactor operating coils. 7/98 998 Square D All Rights Reserved 5

D-Line Contactors, Overload Relays and Accessories Selection Reversing Contactors for Motor Control Control Circuit: AC Kilowatt ratings for international applications 3-pole reversing contactors for ring tongue terminals or bus bar power connections Includes pre-wired power connections q f Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Rated operational current in AC-3 Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c Weight 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V 000 V 0 V up to kw kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 3 5.5 5.5 5.5 7.5 7.5 7.5 9 9 0 0 8 5.5 5 5 5 LC-D0906kk q 0.700 (.55) LC-D096kk f LC-D06kk q 0.700 (.55) LC-D6kk f LC-D806kk q 0.750 (.67) LC-D86kk f LC-D506kk q.00 (.) LC-D56kk f LC-D306kk q.00 (.67) 7.5 5 5 5 8.5 8.5 3 LC-D36kk f 9 8.5 8.5 8.5 8.5 8.5 38 LC-D3806kk q.00 (.67) 30 55 59 59 75 80 75 5 LC-D5006kk f 5.950 (3.) 0 70 80 80 90 00 90 50 LC-D50006kk f 6.000 (3.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages, see page. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0). 6 998 Square D All Rights Reserved 7/98

Horsepower ratings for North American applications Control Circuit: AC Selection Reversing Contactors for Motor Control 3-pole reversing contactors ring tongue terminals or bus bar power connections Pre-wired power connections q f Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c Weight hp hp hp hp hp hp A N/O N/C kg (lb.) 0.5 5 7.5 9 LC-D0906kk q 0.700 (.55) LC-D096kk f 3 3 7.5 0 LC-D06kk q 0.700 (.55) LC-D6kk f 3 5 5 0 5 8 LC-D806kk q 0.750 (.67) LC-D86kk f 3 7.5 7.5 5 0 5 LC-D506kk q.00 (.) LC-D56kk f 5 0 0 0 30 3 LC-D306kk q.00 (.67) LC-D36kk f Not UL listed or CSA certified Not for North American applications 38 LC-D3806kk q.00 (.67) 30 0 75 00 5 LC-D5006kk f 5.950 (3.) 5 5 0 0 50 LC-D50006kk f 6.000 (3.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL Recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D09 to D38: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D5 and D50: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. a Standard control circuit voltages, see page 5. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. f Included with electrical contacts integrated in mechanical interlock (type LA9Dkk0). 7/98 998 Square D All Rights Reserved 7

Selection Reversing Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole reversing contactors with Finger-safe terminals for power cabling Includes pre-wired power connections q LP-D090kk LP-D50kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V Rated operational current in AC-3 0 V up to Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 LP-D090kk q.00 (.67) 3 5.5 5.5 5.5 7.5 7.5 LP-D0kk q.00 (.67) 7.5 9 9 0 0 8 LP-D80kk q.70 (.8) 5.5 5 5 5 LP-D50kk q.750 (3.89) 7.5 5 5 5 8.5 8.5 3 LP-D30kk q.850 (.) Weight Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC 36 8 60 7 0 5 0 50 0 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 8 998 Square D All Rights Reserved 7/98

Control Circuit: DC Horsepower ratings for North American applications Selection Reversing Contactors for Motor Control 3-pole reversing contactors with Fingersafe terminals for power cabling Includes pre-wired power connections q LP-D090kk LP-D50kk Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c hp hp hp hp hp hp A N/O N/C kg (lb.) 0.5 5 7.5 9 LP-D090kk q.00 (.67) 3 3 7.5 0 LP-D0kk q.00 (.67) 3 5 5 0 5 8 LP-D80kk q.70 (.8) 3 7.5 7.5 5 0 5 LP-D50kk q.750 (3.89) 5 0 0 0 30 3 LP-D30kk q.850 (.) Weight Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC 36 8 60 7 0 5 0 50 0 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 7/98 998 Square D All Rights Reserved 9

Selection Reversing Contactors for Motor Control Control Circuit: DC Kilowatt ratings for international applications 3-pole reversing contactors for ring tongue terminals or bus bar power connections Includes pre-wired power connections Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. Rated operational current in AC-3 0 V up to Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c kw kw kw kw kw kw A N/O N/C kg (lb.). 5.5 5.5 9 LP-D0906kk q.00 (.67) 3 5.5 5.5 5.5 7.5 7.5 LP-D06kk q.00 (.67) 7.5 9 9 0 0 8 LP-D806kk q.70 (.8) 5.5 5 5 5 LP-D506kk q.750 (3.89) 7.5 5 5 5 8.5 8.5 3 LP-D306kk q.850 (.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. a DC Coil Selection Uc (Volts) DC 36 8 60 7 0 5 0 50 0 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. Weight 30 998 Square D All Rights Reserved 7/98

Control Circuit: DC Horsepower ratings for North American applications Selection Reversing Contactors for Motor Control 3-pole reversing contactors for ring tongue terminals or bus bar power connections Includes pre-wired power connections Maximum horsepower ratings -phase 50/60 Hz 3-phase 50/60 Hz Maximum inductive current in AC-3 category 600 V Instantantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a DIN rail or screw mounting c hp hp hp hp hp hp A N/O N/C kg (lb.) 0.5 5 7.5 9 LP-D0906kk q.00 (.67) 3 3 7.5 0 LP-D06kk q.00 (.67) 3 5 5 0 5 8 LP-D806kk q.70 (.8) 3 7.5 7.5 5 0 5 LP-D506kk q.750 (3.89) 5 0 0 0 30 3 LP-D306kk q.850 (.) 3-pole reversing contactors for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Weight Auxiliary contact blocks and add-on modules, see pages to 9. c Clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. a DC Coil Selection Uc (Volts) DC 36 8 60 7 0 5 0 50 0 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 7/98 998 Square D All Rights Reserved 3

Selection Changeover Contactors for Resistive Loads Control Circuit: DC -pole changeover contactors with Fingersafe terminals for power cabling Includes pre-wired power connections Utilization category AC- Non inductive loads Maximum rated operational current (θ < 55 C) Instantaneous auxiliary contacts per contactor Contactors supplied with coils. Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting Weight LC-D00kk A N/O N/C kg (lb.) 5 LC-D00kk q 0.700 (.) 0 LC-D500kk q.00 (.) 60 LC-D000kk q.00 (5.33) 80 LC-D6500kk q 3.00 (7.) 5 LC-D8000kk q 3.00 (7.) 00 LC-D500kk f 7.50 (6.)???? lbs -pole changeover contactor pairs, for ring tongue terminals or bus bar connections Includes pre-wired power connections 5 LC-D006kk q 0.700 (.) LP-D6500kk 0 LC-D5006kk q.00 (.) 60 LC-D0006kk q.00 (5.33) 80 LC-D65006kk q 3.00 (7.) 5 LC-D80006kk q 3.00 (7.) 00 LC-D5006kk f 6.50 (6.)???? lbs -pole changeover contactor pairs for connection with slip-on connectors Power connections to be made by the customer For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: UL recognized E686 NLDX x 6.35 mm (0.5 in.) on the power poles and x 6.35 mm (0.5 in.) on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D and D5: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D80: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC 36 8 60 7 0 5 0 50 0 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 3 998 Square D All Rights Reserved 7/98

Selection Changeover Contactors for Resistive Loads Control circuit: DC -pole changeover contactor pairs with Fingersafe terminals for power cabling Includes pre-wired power connections Utilization category AC- Non inductive loads Maximum rated operational current (θ < 55 C) Instantaneous auxiliary contacts per contactor Contactors supplied with coils Catalog number. Complete with code indicating control circuit voltage a c DIN rail or screw mounting Weight LC-D00kk A N/O N/C kg (lb.) 5 LP-D00kk q.00 (.67) 0 LC-D500kk q.750 (3.89) -pole changeover contactor pairs for ring tongue terminals or bus bar power connections 5 LC-D006kk q.00 (.67) 0 LC-D5006kk q.750 (3.89) -pole changeover contactor pairs for connection with slip-on connectors Power connections to be made by the customer LP-D6500kk For contactors LC-D09 and LC-D only, replace the last digit 6 in the above catalog numbers, with a 9. Example: LC-D0906kk becomes LC-D0909kk. These contactors include slip-on connectors: E686 NLDX x 6.35 mm on the power poles and x 6.35 mm on the coil terminals. Accessories (to be ordered separately) Auxiliary contact blocks and add-on modules, see pages to 9. c LC-D and D5: clip-on mounting on 35 mm ( DIN rail AM-DP or screw mounting. LC-D0 to D80: clip-on mounting on 35 mm ( DIN rail AM-DE or 75 mm ( DIN rail AM-DL or screw mounting. LC-D5: clip-on mounting on x 35 mm ( DIN rails AM-DP or screw mounting. adc Coil Selection Uc (Volts) DC 36 8 60 7 0 5 0 50 0 U 0.8 to. Uc JD BD CD ED ND SD FD GD MD UD RD U 0.7 to.5 Uc JW BW CW EW SW FW MW Other voltages from to 0 V, see pages 57 to 60. q Includes mechanical interlock (type LA9Dkk978) without electrical contacts. Installer to complete wiring for electrically interlocking contactor operating coils by utilizing a N/C auxiliary contact integrated in the contactor or optional LADN or LA8DN type auxiliary contact block. 7/98 998 Square D All Rights Reserved 33

Combinations Reversing contactors types LC-D and LP-D Components for assembling reversing contactors and changeover contactor, for customer assembly Contactors Mechanical interlocks Sets of power connections Reversers using identical contactors horizontally mounted type Without electrical interlocking With integral electrical interlocking ( x N.C. contacts) 3-pole reversing contactors L L L3 A 3 5 3 5 A 3 or -pole changeover contactor pairs A A A A /L /L /L3 U V 6 6 6 W 3 5 L L L3 8 7 N /L /L /L3 N A A N 6 8 3 5 7 LC-D09 LC-D LC-D8 LC-D5 LC-D3 LC-D38 LP-D09 LP-D LP-D8 LP-D5 LP-D3 LA9-D09978 LA9-D090 LA9-D69 LA9-D869 LA9-D569 LA9-D369 LA9-D70 (P) LA9-D570 (P) LC-D0 LC-D50 LC-D65 LA9-D50978 LA9-D00 LA9-D6569 LA9-D6570 (P) LP-D0 LP-D50 LP-D65 LC-D80 LC-D95 LA9-D8069 LA9-D8070 (P) LP-D80 LA9-D80978 LA9-D800 LA9-D8069 LA9-D8070 (P LC-D5 LC-D50 Not available LA9-D50 LA9-D569 LA9-D57 (3P) LA9-D570 (P) (D5 only) 3 998 Square D All Rights Reserved 7/98

Selection Components for assembling reversing contactors and changeover contactors, horizontally mounted, for customer assembly Component parts (including mechanical interlock with integrated electrical contacts) With identical contactors c Set of power connections Catalog number Weight kg (lb.) For assembly of 3-pole reversing contactors for motor control Mechanical interlock kit Catalog number Weight kg (lb.) LC/LP-D09/D LA9-D69 0.05 (0.033) LA9-D090 0.060 (0.3) LC/LP-D8 LA9-D869 0.030 (0.066) LA9-D090 0.060 (0.3) LC/LP-D5 LA9-D569 0.030 (0.066) LA9-D090 0.060 (0.3) LC/LP-D3/D38 LA9-D369 0.00 (0.088) LA9-D090 0.060 (0.3) LC/LP-D0/D50 LA9-D6569 0.90 (0.638) LA9-D00 0.70 (0.37) LC/LP-D65 LC-D80/D95 LA9-D8069 0.90 (.078) LA9-D00 0.70 (0.37) LP-D80 LA9-D8069 0.90 (.078) LA9-D800 0.70 (0.37) LC-D5/D50 LA9-D569.50 (3.90) LA9-D50 0.90 (0.638) For assembly of 3-pole changeover contactors LC-D5/D50 LA9-D57 0.960 (.) LA9-D50 0.90 (0.638) For assembly of -pole changeover contactors (3-phase + neutral distribution system) LC/LP-D00 LA9-D70 0.00 (0.0) LA9-D090 0.060 (0.3) LC/LP-D500 LA9-D570 0.00 (0.0) LA9-D090 0.060 (0.3) LC/LP-D000/D6500 LA9-D6570 0.50 (0.330) LA9-D00 0.70 (0.37) LC-D8000 LA9-D8070 0.80 (0.66) LA9-D00 0.70 (0.37) LP-D8000 LA9-D8070 0.80 (0.66) LA9-D800 0.70 (0.37) LC-D500 LA9-D570.60 (.77) LA9-D50 0.90 (0.638) Component parts (including mechanical interlock without electrical contacts) For assembly of 3-pole reversing contactors for motor control LC/LP-D090/D0 LA9-D69 0.05 (0.033) LA9-D09978 0.030 (0.066) LC/LP-D80 LA9-D869 0.030 (0.066) LA9-D09978 0.030 (0.066) LC/LP-D50 LA9-D569 0.030 (0.066) LA9-D09978 0.030 (0.066) LC/LP-D30/D380 LA9-D30 0.00 (0.088) LA9-D09978 0.030 (0.066) LC/LP-D0/D50 LC/LP-D65 LA9-D6569 0.90 (0.638) LA9-D50978 0.55 (0.3) LC-D80/D95 LA9-D8069 0.90 (.078) LA9-D50978 0.55 (0.3) LP-D80 LA9-D8069 0.90 (.078) LA9-D80978 0.80 (0.396) For assembly of -pole changeover contactors (3-phase + neutral distribution system) a LC/LP-D00 LA9-D70 0.00 (0.0) LA9-D09978 0.030 (0.066) LC/LP-D500 LA9-D570 0.00 (0.0) LA9-D09978 0.030 (0.066) LC/LP-D000/D6500 LA9-D6570 0.50 (0.330) LA9-D50978 0.55 (0.3) LC-D8000 LA9-D8070 0.80 (0.66) LA9-D50978 0.55 (0.3) LP-D8000 LA9-D8070 0.80 (0.66) LA9-D80978 0.80 (0.396) c To order the contactors: see pages to 3. a Order contact blocks LA8-DNk or LA-DNk to obtain electrical interlockingof operating coils. See pages and 3. 7/98 998 Square D All Rights Reserved 35

Characteristics Auxiliary contact blocks without dust and damp protected contacts Type LA-D LA-D LA3-D LA8-D c Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 337-, 97-, 97-5, 97-5-, NF C 63-0. VDE 0660, BS 79 Approvals E686 CCN NLDX LR336 Class 3 0 ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Storage - 60 to + 80 C (-76 to +76 F) Ambient air temperature around the device For operation at 80 to 0% of nominal control voltage - 5 to + 55 C (+3 to +3 F) Permissible for operation at nominal control voltage - 0 to + 70 C (-0 to +58 F) Maximum operating altitude Without derating 3000m (8900 ft.) or conductors AWG 8 to Cabling Stranded or solid cable with or without cable end mm to.5 Tightening torque Phillips head No. or Ø 6 mm (3/6 in.) screwdriver 0.8 Nkm (7 lb. in.) Instantaneous and time delay contacts Number of contacts or Rated operational voltage (Ue) Up to V 660 Conforming to IEC 97- V 690 Rated insulation voltage (Ui) Conforming to VDE 00 group C V 750 Conforming to CSA V 600 Rated thermal current (Ith) For ambient temperature 0 C (0 F) A 0 Frequency of operational current Hz 5 to 00 U min V 7 Minimum switching capacity I min ma 5 Short-circuit protection To IEC 97-5- and VDE 0660. gg fuse. A 0 Rated making capacity Conforming to IEC 97-5- I rms A AC: 0; DC: 50 s A 00 Short time rating Permissible for 500 ms A 0 00 ms A 0 Insulation resistance MΩ > 0 Non-overlap time Guaranteed between N.C. and N.O. contacts ms.5 (on opening and closing) Overlap time Guaranteed between N.C. and N.O. on LA-DC ms.5 Time delay (LA-D and LA3-D contact blocks) Accuracy only valid for setting range indicated on the front face c For use on contactors LC-D and LP-D only. Ambient air temperature for operation - 0 to + 70 C (-0 to +58 F) - 0 to + 70 C (-0 to +58 F) Repeat accuracy ± % ± % Drift up to 0.5 million operating cycles + 5 % + 5 % Drift depending on ambient air temperature 0.5 % per C 0.5 % per F 0.5 % per C 0.5 % per F Mechanical durability In millions of operating cycles 30 5 5 30 Operational power of contacts See page 37 36 998 Square D All Rights Reserved 7/98

Characteristics Auxiliary contact blocks without dust and damp protected contacts Operational power of contacts (conforming to IEC 97-5-) AC supply, categories AC- and AC-5 Electrical durability (up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet: making power (cos ϕ 0.7) = 0 times the power broken (cos ϕ 0.). V 8 0/7 0/ 30 380/00 0 600 million operating cycles VA 50 300 00 80 500 500 500 3 million operating cycles VA 80 70 50 90 30 30 30 0 million operating cycles VA 30 65 90 0 30 30 30 Occasional making capacity VA 00 600 7000 3 000 5 000 3 000 9000 0 000 8000 6000 5000 000 3000 000 000 800 600 500 00 300 00 a Breaking limit of contacts for: maximum of 50 operating cycles at 0 s intervals (breaking power = making power x cos ϕ 0.7). Electrical durability of contacts: - for million operating cycles (a). - for 3 million operating cycles (b). - for 0 million operating cycles (c). Thermal limit. 00 80 60 0 b c 8 0 0 0 380 500 0 690 V DC supply, category DC-3 Electrical durability (up to 00 operating cycles/hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the power. V 8 0 0 0 600 million operating cycles W 0 90 75 68 6 58 3 million operating cycles W 70 50 38 33 8 7 0 million operating cycles W 5 8 0 9 Occasional making capacity W 000 700 00 60 0 70 50 000 700 500 300 00 3 Electrical durability of contacts: - for million operating cycles (a). - for 3 million operating cycles (b). - for 0 million operating cycles (c). 3 Breaking limit of contacts for: maximum of 0 operating cycles at 0 s intervals and with current passing for 0.5 s per operating cycle. Thermal limit. 00 0 00 50 0 00 80 60 50 0 30 0 0 8 6 a b c 8 0 0 0 600 V 7/98 998 Square D All Rights Reserved 37

Characteristics Auxiliary contact blocks with dust and damp protected contacts Type LA-DX LA-DZ LA-DY Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 97-5-, VDE 0660 Approvals E686 CCN NLDX LR336 Class 3 0 UL, CSA Protective treatment Conforming to IEC 68 TH TH TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Ambient air temperature around the device Storage Operation - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) - 5 to + 70 C (-3 to +58 F) or conductors AWG 8 to 8 to 8 to Cabling Stranded or solid cable with or without cable end mm to.5 to.5 to.5 Tightening torque Phillips head No. or Ø 6 mm (3/6 in.) flat blade screwdriver 0.8 Nkm (7 lb. in.) 0.8 Nkm (7 lb. in.) 0.8 Nkm (7 lb. in.) Number of contacts Characteristics of dust and damp protected contacts ( non dust & damp protected) Rated operational voltage (Ue) Up to V 50 50 Rated insulation voltage (Ui) Conforming to IEC 97 5- V 50 50 50 Maximum operational current (Ie) ma 500 500 50 U min V 7 7 3 Minimum switching capacity I min ma 0.3 Insulation resistance MΩ > 0 > 0 > 0 Mechanical durability In millions of operating cycles 5 5 5 Materials and technology used for dust and damp protected contacts Characteristics of non dust and damp protected contacts Silver Single break Silver Single break Rated operational voltage (Ue) Up to V 690 Conforming to IEC 97 5- V 690 Rated insulation voltage (Ui) Conforming to UL/CSA V 600 Rated thermal current (Ith) For ambient temperature 0 C A 0 Frequency of operational current Hz 5 to 00 U min V 7 Minimum switching capacity I min ma 5 Short-circuit protection Conforming to IEC 97 5-. gg fuse A 0 Rated making capacity Conforming to IEC 97 5- I rms A c: 0; a: 50 s A 00 Short time rating Permissible for 500 ms A 0 00 ms A 0 Insulation resistance MΩ > 0 Operational power of contacts See page 37 Gold Single break with crossed bars 38 998 Square D All Rights Reserved 7/98

Characteristics Interface Modules Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 55-5 File 6353 CCN NKCR LR336 Class 3 0 Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Ambient air Storage - 0 to + 80 C (-0 to +76 F) temperature Operation at 80 to 0% of nominal control voltage - 5 to + 55 C (-3 to +3 F) around the device Permissible for operation at Uc - 5 to + 70 C (-3 to +58 F) Other characteristics Type LA-DFBQ LA-DFB LA-DFE LA-DLB LA-DLE LA-DWB With relay With relay With relay With relay + override Solid state Rated insulation voltage Conforming to IEC 97- V 00 50 Rated operational voltage Conforming to IEC 97- V 00 50 Indication of input state By integral LED which illuminates when the contactor coil is energized Input signals Control voltage (E-E) V DC DC 8 DC DC 8 DC DC Permissible variation V 7 to 30 7 to 30 33 to 60 7 to 30 33 to 60 5 to 30 Current consumption at 0 C ma 5 5 5 5 5 U V <. <. <.8 <. <.8 <. State 0 guaranteed for I ma < < <.3 < <.3 < State guaranteed for U V 7 7 33 7 33 5 Built-in protections Against reversed polarity By diode Of the input By diode Electrical durability at 0/0 V In millions of operating cycles 3 0 0 3 3 0 Maximum immunity to micro-breaks ms Power dissipated At 0 C W 0.6 0.6 0.6 0.6 0.6 0. For use with contactor Total operating time at Uc (of the contactor) Cabling Tightening torque With to 50 V DC coil LP-D09 to D3 to 50 V coil AC LC-D09 to D50 00 to 50 V coil AC 380 to 5 V coil AC LC-D09 to D50 Operating times depend on the type of contactor electromagnet and its control mode. The closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time O is measured from the moment the coil supply is switched off to the moment the main poles separate. With LA-DF, DL or conductors Stranded or solid cable with or without cable end Phillips head No. or Ø 6 mm (3/6 in.) flat blade screwdriver LC-D09 to D8 LC-D5 to D38 LC-D0 to D65 LC-D80 and D95 LP-D09 to D8 8.5 for 5V 5 for V LC-D09 to D38 LC-D0 to D5 LP-D5 and D3 C ms 0 to 30 3 to 3 8 to 3 8 to 3 8 to 56 60 to 7 O ms 6 to 7 to 3 0 to 8 to 3 8 to 6 0 to 6 AWG 8 to mm to.5 0.8 Nkm (7 lb. in.) 7/98 998 Square D All Rights Reserved 39

Characteristics Electronic serial timer modules Type LA-DT (On-delay) LA-DR (Off-delay) for LC-D Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 55-5 Approvals E686 CCN NLDX LR336 Class 3 0 UL, CSA Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Storage - 0 to + 80 C (-0 to +76 F) Ambient air temperature around the device Operation at 80 to 0% of nominal control voltage - 5 to + 55 C (-3 to +3 F) Permissible for operation at Uc - 5 to + 70 C (-3 to +58 F) Rated insulation voltage (Ui) To IEC 97- and VDE 00 (group C) V 50 Cabling or conductors AWG 8 to Stranded or solid cable with or without cable end mm to.5 Tightening torque Phillips n or Ø 6 mm (3/6 in.) flat blade screwdriver 0.8 Nkm (7 lb.-in.) Control circuit characteristics On input By varistor By varistor Built-in protection Suppression of contactor By varistor By bidirectional peak limiting diode Rated control circuit voltage (Uc) V to 50 AC or DC to 50 DC Permissible variation 0.8 to. Uc 0.8 to. Uc Type of control By mechanical contact only By mechanical contact only connecting cable < 0 m (30 ft.) Time delay characteristics Timing ranges s 0. to ;.5 to 30; 5 to 500 0. to ;.5 to 30; 5 to 500 Repeat accuracy 0 to 0 C ± 3 % (0 ms minimum) ± 3 % (0 ms minimum) Reset time During the time delay period ms 50 5 After the time delay period ms 50 During the time delay period ms 0 0 Immunity to micro-breaks After the time delay period ms Minimum control pulse duration ms 0 Indication of time delay By LED Illuminates during time delay period Illuminates during time delay period Switching characteristics (solid state type) Maximum power dissipated W 3.5 Leakage current ma < 5 < 5 Residual voltage V 3.3 3.3 Short-circuit protection 3 kv; 0.5 joule 3 kv; 0.5 joule Electrical durability In millions of operating cycles 30 30 Operating diagrams LA-DT on-delay electronic timers LA-DR off-delay electronic timers U supply (A-A) Time delay output Contactor coil 0 0 0 0 ms t U supply (A-A) Control (A-B) Time delay output 0 0 t Red LED Contactor coil Red LED 0 998 Square D All Rights Reserved 7/98

Characteristics Control modules, coil suppressor modules and mechanical latch block Environment Approvals Meets the essential requirements of the LV & EMC directives File 6353 CCN NKCR LR336 Class 3 0 Protective treatment Conforming to IEC 68 TH Degree of protection Conforming to VDE 006 Protection against direct finger contact IPX Storage - 0 to + 80 C (-0 to +76 F) Ambient air temperature around the device Operation at 80 to 0% of nominal control voltage - 5 to + 55 C (-3 to +3 F) Permissible for operation at Uc - 5 to + 70 C (-3 to +58 F) Automatic - Manual - Stop modules LA-DM Recommendation The Auto-Man selector switch must only be operated with the Start-Stop ( O - I ) switch in position O Rated insulation voltage Conforming to IEC 97- V 50 Rated operational voltage Conforming to IEC 97- V 50 Protection Against electric shocks kv Built-in protection Contactor coil suppression By varistor Indication By integral LED Illuminates when the contactor coil is energized Electrical durability In operating cycles 0 000 Coil suppressor modules Type LA-DA LA-DB LA-DC LA-DE Type of protection Rated control circuit voltage (Uc) Maximum peak voltage V RC circuit to 5 AC 300% nominal voltage Bidirectional peak limiting diode to 7 AC or DC 00% nominal voltage Diode to 50 DC 00% nominal voltage /8 V Hz 00 50/7 V Hz 00 Natural RC frequency 0/0 V Hz 00 380/5 V Hz 50 Mechanical latch block characteristics Type LA6-DK0 LA6-DK0 LC-D09 to D65 LC-D80 to D50 For mounting on contactor LP-D09 to D65 LP-D80 Approval UL, CSA UL, CSA Rated insulation voltage Conforming to IEC 97 V 690 690 Rated control circuit voltage 50/60 Hz AC and DC V to 5 to 5 AC VA 5 5 Power required For unlatching DC W 30 30 Maximum operating rate In operating cycles per hour 00 00 On-load factor 0 % 0 % Mechanical durability at Uc In millions of operating cycles 0.5 0.5 Varistor to 50 AC or DC 00% nominal voltage Unlatching can be manually operated or electrically controlled (pulsed). The LA6-DK does not include a coil clearing contact. The latch coil and the LC-D operating coil must not be energized or maintained simultaneously. Duration of control signals 00 ms. 7/98 998 Square D All Rights Reserved

Auxiliary Contact Blocks 0-7V AC-DC 50/60Hz E E LA-DN0, DN0 LA6-DK 0 LA6 DK0 LA8-DN LA-DN LA8-DN LC-LP LA-DN, DC LA-DT, DS LA3-DR LA-DX, DY, DZ 998 Square D All Rights Reserved 7/98

Selection - Auxiliary Contact Blocks For type LCk-D and LPk-D: Auxiliary contact blocks Instantaneous auxiliary contact blocks For use in normal operating environments Number of contacts per block Clip-on mounting on contactor Auxiliary Contacts Catalog number Weight Front mount Side mount c f N/O N/C kg (lbs.) LC-D5 to D95 LA-DN0 a 0.00 (0.0) LP-D5 to D80 LA-DN0 a 0.00 (0.0) LA-DN 0.030 (0.066) LC-D09 to D50 LP-D09 to D80 LA-DN0 0.030 (0.066) LA-DN0 0.030 (0.066) LC-D09 to D50 LA8-DN q 0.030 (0.066) LP-D09 to D3 LA8-DN0 q 0.030 (0.066) LA-DN 0.050 (0.) 3 LA-DN3 0.050 (0.) LC-D09 to D50 LA-DN0 0.050 (0.) LP-D09 to D80 LA-DN0 0.050 (0.) 3 LA-DN3 0.050 (0.) LA-DC a 0.050 (0.) With terminal referencing conforming to standard EN 500 LC-D090 to D380 LA-DNM 0.030 (0.066) LP-D090 to to D30 LC/LP-D0900 to D300 LA-DNP 0.030 (0.066) LC-D500/D5000 LC-D0 to D95 LA-DNG 0.030 (0.066) LP-D0 to D80 LA-DNM 0.050 (0.) LC-D090 to D380 LP-D090 to D30 3 LA-DN3M 0.050 (0.) 3 LA-DN3M 0.050 (0.) LA-DNP 0.050 (0.) LC/LP-D0900 to D300 LC-D500/D5000 3 LA-DN3P 0.050 (0.) 3 LA-DN3P 0.050 (0.) LC-D0 to D95 0.050 (0.) LA-DNG LP-D0 to D80 0.050 (0.) Instantaneous auxiliary contact blocks with dust and damp protected contacts For use in harsh industrial environments LC-D09 to D50 to 50 V LA-DX0 0.00 (0.088) LP-D09 to D80 5 to V LA-DY0 f 0.00 (0.088) LC-D09 to D50 to 50 V LA-DZ0 0.050 (0.) LP-D09 to D80 to 50 V LA-DZ3 0.060 (0.3) a Maximum number of blocks per contactor: block from D5 to D38, blocks from D0 to D95. q Set of shims required for mounting on LC-D0 to D95, to be ordered separately, see page 5. f Supplied with grounding terminal connections. c Dust-tight auxiliary contacts (IP5) NEMA rating. 7/98 998 Square D All Rights Reserved 3

Seriplex Module, Time Delay Blocks and Mechanical Latch Blocks 0-7V AC-DC 50/60Hz E E LA-DN0, DN0 LA6-DK 0 LA6 DK0 LA-DN0, DN0 LA8-DN LA-DN LA8-DN LC-LP LA-DN, DC LA-DT, DS LA-SPX LA3-DR LA-DX, DY, DZ 998 Square D All Rights Reserved 7/98

Selection Seriplex module, time delay auxiliary contact blocks and mechanical latch blocks Seriplex Seriplex block per contactor Clip-on front mounting Operates coils up to Approvals File E96 CCN NRAQ LR5353 Class 5 0 Contactor adaptor t module LC-D09 to D80 LP-D09 to D80 Time delay auxiliary contact blocks 77 VAC VDC LA-SPX 0.07 (0.60) Number of contacts block per contactor Time delay Catalog number c Weight Clip-on front mounting Type Setting range kg (lb.) 0. to 3 s a LA-DT0 0.060 (0.3) N.O. + N.C. Mechanical latch blocks LC-D09 to D50 LP-D09 to D80 On-delay Off-delay 0. to 30 s LA-DT 0.060 (0.3) 0 to 80 s LA-DT 0.060 (0.3) to 30 s q LA-DS 0.060 (0.3) 0. to 3 s a LA3-DR0 0.060 (0.3) 0. to 30 s LA3-DR 0.060 (0.3) 0 to 80 s LA3-DR 0.060 (0.3) Unlatching control Manual or electric block per contactor Clip-on front mounting LC-D09 to D65 LP-D09 to D65 LC-D80 to D50 LP-D80 Catalog number to be completed f Weight kg (lb.) LA6-DK0k 0.070 (0.5) LA6-DK0k 0.090 (0.98) c Sealing cover, LA9-D90 to be ordered separately, see page 5. a With extended scale from 0. to 0.6 s. q With switching time of 0 ms ± 5 ms between opening of the N.C. and closing of the N.O. contact. f Standard control circuit voltages (for other voltages, please consult our local representatives or agents). Volts 50/60 Hz, a 3/36 /8 60/7 00 0/7 0/0 56/77 380/5 Code B C E EN K F M U Q t For more information refer to Seriplex catalog 833OCT960 7/98 998 Square D All Rights Reserved 5

Selection - Electronic Timers and Interface Modules LA-DT LA-DR LA-DF LA-DL LA-DW LA-DM LC-D LA-DT LA-DF LA-DL LA-DM 6 LP-D 998 Square D All Rights Reserved 7/98

Selection Electronic Timers and Interface Modules Electronic serial timer modules c The solid state modules delay the energizing and de-energizing of the contactor coil. a Operational voltage to energize contactor coil Time delay Catalog number Weight AC DC to 50 V 00 to 50 V to 50 V kg (lb.) On-delay type D09 to D38 D0 to D50 D09 to D3 Off-delay type D09 to D8 D5 to D50 0. to s LA-DT0U 0.00 (0.088).5 to 30 s LA-DTU 0.00 (0.088) 5 to 500 s LA-DTU 0.00 (0.088) 0. to s LA-DR0U 0.050 (0.).5 to 30 s LA-DRU 0.050 (0.) 5 to 500 s LA-DRU 0.050 (0.) Interface modules c Operational voltage to energize contactor coil Input signal voltage DC Catalog number Weight AC DC to 50 V 00 to 50 V 380 to 5 V to 50 V E-E kg (lb.) Relay interface D09 to D50 V LA-DFBQ 0.055 (0.) V LA-DFB 0.055 (0.)!??! D09 to D50 D09 to D3 8 V LA-DFE 0.055 (0.)!??! Relay interface with manual override switch (output forced ON ) V LA-DLB 0.05 (0.099) D09 to D50 D09 to D3 8 V LA-DLE 0.05 (0.099) Solid state interface D09 to D38 D0 to D5 V LA-DWB 0.05 (0.099) Auto-Man-Stop control modules c For local override operation tests with -position Auto-Man switch and O-I switch Operational voltage to energize contactor coil Catalog number Weight AC DC to 00 V 00 to 50 V to 00 V 00 to 50 V kg (lb.) D09 to D50 D09 to D3 LA-DMK 0.00 (0.088) D09 to D50 D09 to D3 LA-DMU 0.00 (0.088) c Mounted directly on terminals A and A screws. a For V, operation, the contactor must be fitted with a V coil (code Z5 for 50 Hz, Z6 for 60 Hz or ZD for DC). 7/98 998 Square D All Rights Reserved 7

Coil Suppressor Modules LA-Di LA-Di LC-D LA-Di LA-Di, Di3 LP-D 8 998 Square D All Rights Reserved 7/98

Selection Coil suppressor modules RC circuits (resistor-capacitor) c Mounted at top For use with contactor a Reference Weight of contactor on coil terminals A Rating Type and A AC DC V V kg Clip-on mounting and to 8 LA-DAE 0.0 (0.06) connection without tools to the contactor 50 to 7 LA-DAG 0.0 (0.06) D09 to D38 coil terminals. Mounting of an input module is still possible 0 to 0 LA-DAU 0.0 (0.06) Screw connection to the contactor coil terminals. Mounting ot the input module not possible. D09 to D50 Varistors (peak limiting) q Clip-on mounting and electrical connection. Mounting of an input module is still possible Screw mounting Diodes f Clip-on mounting and electrical connection. Mounting of an input module is still possible Screw mounting D09 to D38 D09 to D38 D0 to D5 D0 to D5 Bidirectional peak limiting diode t Clip-on mounting and electrical connection. Mounting of an input module is still possible Screw connection to the contactor coil terminals. Mounting ot the input module not possible. to 8 LA-DAE 0.08 (0.039) 50 to 7 LA-DAG 0.08 (0.039) 0 to 0 LA-DAU 0.08 (0.039) 380 to 5 LA-DAN 0.08 (0.039) to 8 to 8 LA-DEE 0.0 (0.06) 50 to 7 50 to 7 LA-DEG 0.0 (0.06) 0 to 50 0 to 50 LA-DEU 0.0 (0.06) to 8 to 8 LA-DEE 0.08 (0.039) 50 to 7 50 to 7 LA-DEG 0.08 (0.039) 0 to 50 0 to 50 LA-DEU 0.08 (0.039) to 8 LA-DEE 0.08 (0.039) 50 to 7 LA-DEG 0.08 (0.039) 0 to 50 LA-DEU 0.08 (0.039) to 8 LA-DE3E 0.08 (0.039) 50 to 7 LA-DE3G 0.08 (0.039) 0 to 50 LA-DE3U 0.08 (0.039) D09 to D3 to 50 LA-DCU 0.0 (0.06) D09 to D3 to 50 LA-DCU 0.08 (0.039) D0 to D80 to 50 LA-DC3U 0.08 (0.039) D09 to D38 D09 to D3 LA-DBB 0.0 (0.06) 7 LA-DBS 0.0 (0.06) LA-DBB 0.0 (0.06) 7 LA-DBS 0.0 (0.06) D09 to D95 LA-DBB 0.08 (0.039) 7 LA-DBS 0.08 (0.039) D09 to D3 LA-DBB 0.08 (0.039) 7 LA-DBS 0.08 (0.039) D0 to D80 LA-DB3B 0.08 (0.039) 7 LA-DB3S 0.08 (0.039) c Effective protection for circuits highly sensitive to high frequency interference. For use only in cases where the voltage is virtually sinusoidal, i.e. - 5% total harmonic distortion. Voltage limited to 3 Uc max and oscillating frequency limited to 00 Hz max. Slight increase in drop-out time (. to times the normal time). a For satisfactory protection, a suppressor module must be fitted across the coil of each contactor. q Protection provided by limiting the transient voltage to Uc max. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (. to.5 times the normal time). f No overvoltage or oscillating frequency. Increase in drop-out time (6 to 0 times the normal time). Polarised component. t Protection provided by limiting the transient voltage to Uc max. Maximum reduction of transient voltage peaks. 7/98 998 Square D All Rights Reserved 9

Selection - Contactors and Reversing Contactors LA9-D60 LA9-D860 LA9-D096 LA9-D8096 LA9-D360 LA9-D560 LA9-D6 LA9-D8096 LA9-D0963 LA9-D56 LA9-D6 LA9-D80963 LA9-D8067 LA9-D6567 LA9-D563 LA9-D63 LC-D3, D38 LP-D3 LC-D8 LP-D8 LC-D80, D95 LP-D80 LC-D0, D50, D65 LP-D0, D50, D65 LC-D5 LP-D5 LA9-D9 LC-D09, D LP-D09, D LA9-D93 50 LA9-D9 998 Square D All Rights Reserved 7/98

Types LCk-D and LPk-D Accessories for main pole and control connections Selection - Contactors and Reversing Contactors LA9-D860 LA9-D550k LA9-D560k Description Connectors for larger cable sizes IP0 Finger-safe terminals for stranded or solid cable Connectors for ring tongue terminals or bus bar Links for parallel connection of For use on contactors Sold in lots of Catalog number Weight LC LP kg (lb.) -pole 0 mm D09, D D09, D LA9-D60 0.030 (0.066) 3-pole 5 mm D500 D3, D38 D3 LA9-D360 0.00 (0.088) D8 D8 LA9-D860 0.035 (0.077) -pole 5 mm D5 D5 LA9-D560 0.050 (0.) 3-pole 0 mm D5, D50 D5, D50 LA9-D5603 0.50 (0.88) -pole 0 mm D5 D5 LA9-D560 0.730 (.606) 3-pole D5, D50 D5, D50 LA9-D5503 0.30 (0.506) -pole D5 D5 LA9-D550 0.30 (0.70) poles 3 poles (Wye-delta shorting strap) D09, D D09, D 0 LA9-D6 0.0 (0.06) D5 D5 0 LA9-D56 0.060 (0.3) D0 to D65 D0 to D65 LA9-D096 0.0 (0.06) D80, D95 D80 LA9-D8096 0.060 (0.3) D09, D D09, D 0 LA9-D6 0.003 (0.006) D80, D95 D80 LA9-D8096 0.080 (0.76) D09, D D09, D LA9-D63 0.0 (0.053) D5 D5 LA9-D563 0.07 (0.037) poles D0 to D65 D0 to D65 LA9-D0963 0.070 (0.5) D80, D95 D80 LA9-D80963 0.00 (0.) Staggered coil connection D0 to D80 0 LA9-D09966 0.006 (0.03) Control circuit take-off from main pole Spreaders for increasing the pole pitch to 5 mm D500, D5000 D0 to D65 0 LA9-D6567 0.00 (0.0) D80 0 LA9-D8067 0.00 (0.0) D500. D5000 3 GV7-AC03 0.80 (0.00) LA9-D6 LA9-D8096 LA9-D6567 7/98 998 Square D All Rights Reserved 5

Selection - Contactors and Reversing Contactors Contactors and reversing contactors types LCk-D and LPk-D Sets of contacts For contactor Type Catalog number Weight kg (lb.) LC-D500 LA5-D5803 0.0 (0.8) 3-pole LC-D5000 LA5-D5803 0.0 (0.8) -pole LC-D500 LA5-D580 0.80 (0.66) Arc chamber LC-D500 LA5-D550 0.360 (0.79) 3-pole LC-D5000 LA5-D5050 0.360 (0.79) -pole LC-D500 LA5-D550 0.60 (.0) Accessories for protection and marking LA9-D9 Description For use on Sold in lots of Catalog Weight number Contactors Add-on blocks AC DC kg (lb.) Miniature fuse holder type 5 x 0 with A-50 V fuse D09 to D50 D09 to D80 LA9-D9 0.05 (0.055) Legend holder 8 x mm snap-in Legend holder 8 x 7 mm snap-in D09 to D50 D09 to D80 LA-D ( contacts) LA-D, LA3-D, LA6-DK LA-DN ( contacts) LA-D Bag of 300 labels (blank, self-adhesive) 7 x mm D09 to D50 D09 to D80 ( contacts) LA-D, LA3-D, LA6-DK 00 LA9-D9 0.00 (0.00) 00 LA9-D90 0.00 (0.00) LA9-D93 0.00 (0.00) Bag of 00 labels (blank, self-adhesive) 7 x 6 mm LA-DN LA9-D9 0.00 (0.00) ( contacts) Sealing cover (for time-delay LA, LA3-D LA9-D90 0.005 (0.0) auxiliary contact block) Mounting accessories 35mm DIN rail (7.5mm deep x mm long) D09 to D38 AM-DP00 0.650 (.0) 35mm DIN rail (5mm deep x mm long) D09 to D38 AM-ED00.30 (.880) 75mm DIN rail (5mm deep x mm long) D0 to D95 AM-DL00 3.000 (6.600) Adaptor for mounting on ' rail D09 to D38 D09 to D3 LA9-D973 0.05 (0.055) Mounting plates for fixing on ' D09 to D8 D09 to D8 0 DX-AP5 0.065 (0.3) rails (0 mm fixing centers) D5 and D38 D5 and D38 0 DX-AP6 0.08 (0.80) Mounting plate Replacement F5, F50 by D5.D50 LA9-D730 0.360 (0.79) Set of shims for attacing side-mounting blocks LA8-DN on LC-D0 to D95 contactors LA9-D5 0.00 (0.0) 5 998 Square D All Rights Reserved 7/98

AC coils For contactors LC-D09, D, D8, D500 D-Line Contactors, Overload Relays and Accessories Selection LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 Hz: 60 VA, 60 Hz: 70 VA. - sealed (cos ϕ = 0.3) 50 Hz: 7 VA, 60 Hz: 7.5 VA. Operating range (θ 55 C): 0.8 to. Uc. 50 Hz 60 Hz a 6.3 0.6 LX-DZ5.98 0. LX-DZ6 0.070 (0.5) 6.8 0.3 LX-DB5 5.5 0.5 LX-DB6 0.070 (0.5) 3.6 0.8 LX-DC5 0.070 (0.5).3 0.93 LX-DD5 0.070 (0.5) 8 8.05. LX-DE5.09.0 LX-DE6 0.070 (0.5) 0 8. 5.7 LX-DF5 6.6.5 LX-DF6 0.070 (0.5) 0 39. 5. LX-DG6 0.070 (0.5) 7 9.5 7.5 LX-DG5 0.070 (0.5) 08 7.8 6.6 LX-DL6 0.070 (0.5) 0 90. 8.5 LX-DM6 0.070 (0.5) 0/30 63.3 3 LX-DM5 0.070 (0.5) 30 69.7 5 LX-DP5 0.070 (0.5) 0 76.6 5 LX-DU5 587. LX-DU6 0.070 (0.5) 56 86 3 LX-DW5 0.070 (0.5) 77 78.5 30 LX-DW6 0.070 (0.5) 380 86 55 LX-DQ6 0.070 (0.5) 380/00 88 67 LX-DQ5 0.070 (0.5) 00 069 68 LX-DV5 0.070 (0.5) 5 9 78 LX-DN5 86 69 LX-DN6 0.070 (0.5) 0 59 8 LX-DR5 89 7 LX-DR6 0.070 (0.5) 80 30 85 LX-DT6 0.070 (0.5) 500 385 07 LX-DS5 0.070 (0.5) 575 33 9 LX-DS6 0.070 (0.5) 600 3678 35 LX-DX6 0.070 (0.5) 660 563 90 LX-DY5 0.070 (0.5) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50/60 Hz: 70 VA to 50 Hz. - sealed (cos ϕ = 0.3) 50/60 Hz: 8 VA to 50 Hz. Operating range (θ 55 C): 0.85 to. Uc. 50/60 Hz a 5.6 0. LX-DZ7 0.070 (0.5) 6.9 0.6 LX-DB7 0.070 (0.5) 9.5 0.77 LX-DD7 0.070 (0.5) 8 5 LX-DE7 0.070 (0.5) 0 30 5.5 LX-DF7 0.070 (0.5) 5 LX-DFE7 0.070 (0.5) 0 59 6.7 LX-DG7 0.070 (0.5) 0/30 q 539 LX-DM7 0.070 (0.5) 30 595 LX-DP7 0.070 (0.5) 30/0 f 65 5 LX-DU7 0.070 (0.5) 380/00 580 60 LX-DQ7 0.070 (0.5) 00 80 6 LX-DV7 0.070 (0.5) 5 938 7 LX-DN7 0.070 (0.5) 0 79 LX-DR7 0.070 (0.5) Weight c The last digits of the reference represent the voltage code. a Voltage for special coils in contactors with LA-DT or LA-DR electronic serial timer modules, with V supply. q This coil can be used on 0 V at 60 Hz. f This coil can be used on 30/0 V at 50 Hz and at 0 V only at 60 Hz. 7/98 998 Square D All Rights Reserved 53

D-Line Contactors, Overload Relays and Accessories Selection AC coils For contactors LC-D5 (except LC-D500), D3, D38 LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 Hz: 90 VA, 60 Hz: 00 VA. - sealed (cos ϕ = 0.3) 50 Hz: 7.5 VA, 60 Hz: 8.5 VA. Operating range (θ 55 C): 0.8 to. Uc. 50 Hz 60 Hz a 3.5 0.3 LX-DZ5.9 0. LX-DZ6 0.070 (0.5).5 0.5 LX-DB5 3.5 0.8 LX-DB6 0.070 (0.5) 3 8.6 0.5 LX-DC5 0.070 (0.5). 0.78 LX-DD5 0.070 (0.5) 8 8.6. LX-DE5.5 0.7 LX-DE6 0.070 (0.5) 0 05 5. LX-DF5 8 3.8 LX-DF6 0.070 (0.5) 0 98.5 LX-DG6 0.070 (0.5) 7 36 7. LX-DG5 0.070 (0.5) 08 7 LX-DL6 0.070 (0.5) 0 35 5 LX-DM6 0.070 (0.5) 0/30 3 LX-DM5 0.070 (0.5) 30 5 3 LX-DP5 0.070 (0.5) 0 56 5 LX-DU5 05 8 LX-DU6 0.070 (0.5) 56 565 9 LX-DW5 0.070 (0.5) 77 55 LX-DW6 0.070 (0.5) 380 00 30 LX-DQ6 0.070 (0.5) 380/00 306 6 LX-DQ5 0.070 (0.5) 00 389 73 LX-DV5 0.070 (0.5) 5 595 76 LX-DN5 0.070 (0.5) 0 70 85 LX-DR5 35 6 LX-DR6 0.070 (0.5) 80 605 7 LX-DT6 0.070 (0.5) 500 68 0 LX-DS5 0.070 (0.5) 575 360 03 LX-DS6 0.070 (0.5) 600 80 3 LX-DX6 0.070 (0.5) 660 398 9 LX-DY5 0.070 (0.5) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50/60 Hz: 00 VA to 50 Hz. - sealed (cos ϕ = 0.3) 50/60 Hz: 8.5 VA to 50 Hz. Operating range (θ 55 C): 0.85 to. Uc. 50/60 Hz a 3. 0.8 LX-DZ7 0.085 (0.87).3 0.3 LX-DB7 0.085 (0.87) 3.5 0.69 LX-DD7 0.085 (0.87) 8 6 0.9 LX-DE7 0.085 (0.87) 0 9.9 LX-DF7 0.085 (0.87) 5 LX-DFE7 0.085 (0.87) 0 07 5.5 LX-DG7 0.085 (0.87) 0/30 q 367 6 LX-DM7 0.085 (0.87) 30 377 LX-DP7 0.085 (0.87) 30/0 f 5 3 LX-DU7 0.085 (0.87) 380/00 86 3 LX-DQ7 0.085 (0.87) 00 00 65 LX-DV7 0.085 (0.87) 5 383 70 LX-DN7 0.085 (0.87) 0 78 78 LX-DR7 0.085 (0.87) Weight c The last digits of the reference represent the voltage code. a Voltage for special coils in contactors with LA-DT or LA-DR electronic serial timer modules, with V supply. q This coil can be used on 0 V at 60 Hz. f This coil can be used on 30/0 V at 50 Hz and at 0 V only at 60 Hz. 5 998 Square D All Rights Reserved 7/98

AC coils For contactors LC-D0, D50, D65, D80, D95 D-Line Contactors, Overload Relays and Accessories Selection LX-D6kk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 Hz: 00 VA, 60 Hz: 0 VA. - sealed (cos ϕ = 0.3) 50 Hz: 0 VA, 60 Hz: VA. Operating range (θ 55 C): 0.85 to. Uc. 50 Hz 60 Hz. 0.09 LX-D6B5.05 0.06 LX-D6B6 0.80 (0.66) 3.6 0.6 LX-D6C5 0.80 (0.66). 0.7 LX-D6D5 0.80 (0.66) 8 5.5 0.35 LX-D6E5. 0.3 LX-D6E6 0.80 (0.66) 0 3.9 LX-D6F5. LX-D6F6 0.80 (0.66) 0 8.5 LX-D6G6 0.80 (0.66) 7. LX-D6G5 0.80 (0.66) 08 86.3 LX-D6L6 0.80 (0.66) 0 98.8 LX-D6M6 0.80 (0.66) 0/30 7 7.5 LX-D6M5 0.80 (0.66) 30 33 8. LX-D6P5 0.80 (0.66) 0 5 8.7 LX-D6U5 0 5.7 LX-D6U6 0.80 (0.66) 56 66 0 LX-D6W5 0.80 (0.66) 77 57 8 LX-D6W6 0.80 (0.66) 380 300 LX-D6Q6 0.80 (0.66) 380/00 38 LX-D6Q5 0.80 (0.66) 00 5 LX-D6V5 0.80 (0.66) 5 63 6 LX-D6N5 0.80 (0.66) 0 53 30 LX-D6R5 39 9 LX-D6R6 0.80 (0.66) 80 80 3 LX-D6T6 0.80 (0.66) 500 668 38 LX-D6S5 0.80 (0.66) 575 675 33 LX-D6S6 0.80 (0.66) 600 775 36 LX-D6X6 0.80 (0.66) 660 0 67 LX-D6Y5 0.80 (0.66) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) 50 /60 Hz: 5 VA to 50 Hz. - sealed (cos ϕ = 0.3) 50/60 Hz: 6 VA to 50 Hz. Operating range (θ 55 C): 0.85 to. Uc. 50/60 Hz. 0.08 LX-D6B7 0.80 (0.66) 3.5 0.5 LX-D6D7 0.80 (0.66) 8 5 0.3 LX-D6E7 0.80 (0.66) 0 6.7 LX-D6F7 0.80 (0.66) 5 LX-D6FE7 0.80 (0.66) 0 3 LX-D6G7 0.80 (0.66) 0/30 a 0 6.7 LX-D6M7 0.80 (0.66) 30 5 7.7 LX-D6P7 0.80 (0.66) 30/0 q 3 8.3 LX-D6U7 0.80 (0.66) 380/00 f 30 0 LX-D6Q7 0.80 (0.66) 00 39 3 LX-D6V7 0.80 (0.66) 5 390 LX-D6N7 0.80 (0.66) 0 0 7 LX-D6R7 0.80 (0.66) Weight c The last digits of the reference represent the voltage code. a For use on 30 V 50 Hz, apply a multiplying factor of 0.6 to the mechanical durability of the contactor, see pages 6 and 7. This coil can be used on 0 V at 60 Hz. q This coil can be used on 30/0 V at 50 Hz and at 0 V only at 60 Hz. f For use on 00 V 50 Hz, apply a multiplying factor of 0.6 to the mechanical durability of the contactor, see pages 6 and 7. 7/98 998 Square D All Rights Reserved 55

D-Line Contactors, Overload Relays and Accessories Selection AC coils For contactors LC-D5 LX-D8kk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c V Ω H Ω H kg (lb.) Specifications Average consumption at 0 C: - inrush (cos ϕ = 0.75) -50 or 60 Hz: 300 VA. - sealed (cos ϕ = 0.3) -50 or 60 Hz: VA. Operating range (θ 55 C): 0.85 to. Uc. 50 Hz 60 Hz. 0.09 LX-D8B5 0.87 0.07 LX-D8B6 0.80 (0.66) 3. 0.7 LX-D8C5 0.80 (0.66) 3.9 0.8 LX-D8D5 0.80 (0.66) 8.5 0.36 LX-D8E5 3.9 0.8 LX-D8E6 0.80 (0.66) 0 6.53.00 LX-D8F5 9.97.5 LX-D8F6 0.80 (0.66) 5 6.53.00 LX-D8FE5 0.80 (0.66) 0.0.70 LX-D8G6 0.80 (0.66) 7 3.75. LX-D8FC5 0.80 (0.66) 08 67.9 5.06 LX-D8L6 0.80 (0.66) 0 0.77 7.65 LX-D8M5 79.6 5.69 LX-D8M6 0.80 (0.66) 30 0.77 8.9 LX-D8P5 0.80 (0.66) 0 5.5 8.89 LX-D8U5 97.0 6.75 LX-D8U6 0.80 (0.66) 77 5.75 8.89 LX-D8W6 0.80 (0.66) 380 338.5.6 LX-D8Q5 3.07 7.0 LX-D8Q6 0.80 (0.66) 00 368.3 5.55 LX-D8V5 0.80 (0.66) 5 368.3 7.65 LX-D8N5 0.80 (0.66) 0.56 30.3 LX-D8R5 338.5.6 LX-D8R6 0.80 (0.66) 80 368.3 5.55 LX-D8T6 0.80 (0.66) 500 566.6 38. LX-D8S5 0.80 (0.66) Weight For contactors LC-D5, D50 Specifications Average consumption at 0 C: - inrush: cos ϕ = 0.9-50 VA. - sealed: cos ϕ = 0.9-6 VA. Operating range (θ 55 C): 0.8 to.5 Uc. Coils with built-in surge suppression device, class B 50/60 Hz 7 3.03 LX-D8B7 0.300 (0.66) 3 30 8.8 LX-D8C7 0.300 (0.66) 98 3.3 LX-D8D7 0.300 (0.66) 8 06.9 LX-D8E7 0.300 (0.66) 0 377 09.69 LX-D8F7 0.300 (0.66) 5 377 09.69 LX-D8FE7 0.300 (0.66) 0 377 09.69 LX-D8G7 0.300 (0.66) 7 6586 5.65 LX-D8FC7 0.300 (0.66) 08 0 895 60.5 LX-D8L7 0.300 (0.66) 0 9895 0.7 LX-D8M7 0.300 (0.66) 30 9895 0.7 LX-D8P7 0.300 (0.66) 0 9895 0.7 LX-D8U7 0.300 (0.66) 77 988 533.7 LX-D8UE7 0.300 (0.66) 380 0 8. LX-D8Q7 0.300 (0.66) 00 0 8. LX-D8V7 0.300 (0.66) 5 0 8. LX-D8N7 0.300 (0.66) 0 50 507.7 LX-D8R7 0.300 (0.66) 80 3 9 938. LX-D8T7 0.300 (0.66) 500 3 9 938. LX-D8S7 0.300 (0.66) c The last digits of the reference represent the voltage code. 56 998 Square D All Rights Reserved 7/98

DC coils For contactors LP-D09, D, D8 D-Line Contactors, Overload Relays and Accessories Selection LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: 9 W. Operating range (θ 55 C): 0.8 to. Uc. 7 0.79 LX-DJD 0.75 (0.385) a 5..6 LX-DZD 0.75 (0.385) 7 3. LX-DBD 0.75 (0.385) 36 9.7 7. LX-DCD 0.75 (0.385) 8 67.9 LX-DED 0.75 (0.385) 60 9 LX-DND 0.75 (0.385) 7 609 6 LX-DSD 0.75 (0.385) 0 6.8 LX-DFD 0.75 (0.385) 5 78 77.8 LX-DGD 0.75 (0.385) 0 535 LX-DMD 0.75 (0.385) 50 633 7 LX-DUD 0.75 (0.385) 0 9 785 793 LX-DRD 0.75 (0.385) For contactors LP-D5, D3 Specifications Average consumption: W. Operating range (θ 55 C): 0.8 to. Uc. 3.3 0.73 LX-DJD 0.65 a 36.. LX-DZD 0.65 53.9 LX-DBD 0.65 36 0.3 7.7 LX-DCD 0.65 8.3 LX-DED 0.65 LX-Dkk 60 33 7.8 LX-DND 0.65 7 73 7.5 LX-DSD 0.65 0 63.6 LX-DFD 0.65 5 3 8 LX-DGD 0.65 0 6 37 LX-DMD 0.65 50 60 338 LX-DUD 0.65 0 7 50 93 LX-DRD 0.65 c The last digits of the reference represent the voltage code. a Voltage for special coils in contactors with LA-DT or LA-DR electronic serial timer modules, with V supply. 7/98 998 Square D All Rights Reserved 57

D-Line Contactors, Overload Relays and Accessories Selection DC coils For contactors LP-D0, D50, D65 LX-D6kk Control circuit voltage Uc Average resistance at 0 C ± 0% Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: W. Operating range: 0.85 to. Uc. 7. 0. LX-D6JD 0.5 (0.93) 6.8.69 LX-D6BD 0.5 (0.93) 36 58 3.55 LX-D6CD 0.5 (0.93) 8 09 6.86 LX-D6ED 0.5 (0.93) 60 73 0.9 LX-D6ND 0.5 (0.93) 7 3.7 LX-D6SD 0.5 (0.93) 0 560 35.8 LX-D6FD 0.5 (0.93) 5 77 5. LX-D6GD 0.5 (0.93) 0 55 LX-D6MD 0.5 (0.93) 50 90 85 LX-D6UD 0.5 (0.93) 0 9080 57 LX-D6RD 0.5 (0.93) For contactors LP-D80 Specifications Average consumption: W. Operating range: 0.85 to. Uc. 6.6 0.6 LX-D7JD 0.680 (.96) 7.89 LX-D7BD 0.680 (.96) 36 57 LX-D7CD 0.680 (.96) 8 07 7.5 LX-D7ED 0.680 (.96) LX-D7kk 60 70.9 LX-D7ND 0.680 (.96) 7 30 6. LX-D7SD 0.680 (.96) 0 56 39.5 LX-D7FD 0.680 (.96) 5 78 50.3 LX-D7GD 0.680 (.96) 0 5 55 LX-D7MD 0.680 (.96) 50 850 00 LX-D7UD 0.680 (.96) 0 995 60 LX-D7RD 0.680 (.96) c The last digits of the reference represent the voltage code. 58 998 Square D All Rights Reserved 7/98

DC coils For contactors LC-D5, D50 Control circuit voltage Uc D-Line Contactors, Overload Relays and Accessories Selection Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: 6 W. Operating range: 0.7 to. Uc. Coils with built-in surge suppression, class B. 7 3.03 LX-D8BD 0.300 (0.66) 8 06.9 LX-D8ED 0.300 (0.66) 60 673 38. LX-D8ND 0.300 (0.66) 7 500 56.7 LX-D8SD 0.300 (0.66) 0 377 09.69 LX-D8FD 0.300 (0.66) 5 6586 5.65 LX-D8GD 0.300 (0.66) 0 9895 0.7 LX-D8MD 0.300 (0.66) 50 8 0 35.0 LX-D8UD 0.300 (0.66) 0 50 68.66 LX-D8RD 0.300 (0.66) LX-D8kk c The last digits of the reference represent the voltage code. 7/98 998 Square D All Rights Reserved 59

D-Line Contactors, Overload Relays and Accessories Selection Wide range DC coils (for greater voltage operating range) For contactors LP-D09, D, D8 LX-Dkk Control circuit voltage Uc Average resistance at 0 C ± 0 % Inductance of closed circuit Catalog number c Weight V Ω H kg (lb.) Specifications Average consumption: W. Operating range: 0.7 to.5 Uc. Coils with TH treatment as standard. 5.6 0.7 LX-DJW f 0.75 (0.385) 58.7.9 LX-DBW f 0.75 (0.385) 36.6 5.3 LX-DCW f 0.75 (0.385) 8 3 9.9 LX-DEW f 0.75 (0.385) 7 530. LX-DSW f 0.75 (0.385) 0 05. LX-DFW f 0.75 (0.385) 0 593 85 LX-DMW f 0.75 (0.385) For contactors LP-D5, D3 LX-Dkk Specifications Average consumption: 3 W. Operating range: 0.7 to.5 Uc. Coils with TH treatment as standard..3 0.68 LX-DJW f 0.65 (0.583) 9..7 LX-DBW f 0.65 (0.583) 36 00.7 5.57 LX-DCW f 0.65 (0.583) 8 99 0.8 LX-DEW f 0.65 (0.583) 7 0.3 LX-DSW f 0.65 (0.583) 0 9 5 LX-DFW f 0.65 (0.583) 0 3953 08 LX-DMW f 0.65 (0.583) For contactors LP-D0, D50, D65 LX-D6kk Specifications Average consumption: W. Operating range: 0.75 to. Uc. Coils with TH treatment as standard. 6.8 0.5 LX-D6JW f 0.5 (0.93) 30.9 LX-D6BW f 0.5 (0.93) 36 53 3.5 LX-D6CW f 0.5 (0.93) 8 0 7. LX-D6EW f 0.5 (0.93) 7 5. LX-D6SW f 0.5 (0.93) 0 580 38.3 LX-D6FW f 0.5 (0.93) 0 0 0 LX-D6MW f 0.5 (0.93) For contactors LP-D80 Specifications Average consumption: 3 W. Operating range: 0.75 to. Uc. Coils with TH treatment as standard. 6. 0.9 LX-D7JW f 0.680 (.96) 3.5.75 LX-D7BW f 0.680 (.96) 36 5.9.8 LX-D7CW f 0.680 (.96) 8 9. 7 LX-D7EW f 0.680 (.96) 7 0 5.7 LX-D7SW f 0.680 (.96) 0 83 36 LX-D7FW f 0.680 (.96) 0 9 LX-D7MW f 0.680 (.96) c The last digits of the reference represent the voltage code. f Wide range coils cannot be used on contactors utilizing both front and side mounted auxiliary contact blocks. 60 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Dimensions Contactors, types LC-D LC-D09, D LC-D8, LC-D500 Dimensions shown in millimeters (mm X.039 = inches) LC-D50, D50, D50 LC-D3 = = 0 Minimum electrical clearance c c(la) c(la6-dk0) c3(la,la3) 7,5 (LA8) LA 77(Di) 90(Di) 5,5 (LA8) 97(3)(DF,DT) 05(3) (DM,DR,DW,DL) 0 Minimum electrical clearance c c(la) c(la6-dk0) c3(la,la3) 8,5 (LA8) LA 87(Di) 00(Di) 56,5 (LA8) 07(3)(DF,DT) (DM,DR,DW,DL) 5(3) LC- c c c c c3 a LC- c c c c c3 a D09, D 80 3 5 33 D50, D50, D50 93 7 38 6 D8, D500 85 8 30 38 D3 99 3 5 () With or contacts. () With or contacts; contact = 0 (D5) and 5 (D3) (LA-DN0 or DN0) () + mm with sealing cover. () + mm with sealing cover. (3) With or without combined use of a coil suppressor module (LA-DA, DB, DE). (3) With or without combined use of a coil suppressor module (LA-DA, DB, DE). LC-D0, D50, D65 LC-D80, D95 8 3 Minimum electrical clearance 7 LA 35(Di, Di3) (DF,DT) 50(DM,DR,DW,DL) Minimum electrical clearance 7 LA 35(Di, Di3) (DF,DT) 50(DM,DR,DW,DL) () 6()(LA) 57(LA6-DK0) 65()(LA,LA3),5 (LA8) (3),5 (LA8) 5() 53()(LA) 65(LA6-DK0) 73()(LA,LA3),5 (LA8) (3),5 (LA8) () With or contacts; contact = 39 (LA-DN0 or DN0) () With or contacts; contact = 7 (LA-DN0 or DN0) () + mm with sealing cover. () + mm with sealing cover. (3) 75: 3-pole, 85: -pole. (3) 85: 3-pole, 96: -pole. () 5: LC-Dkk008. () 0: LC-Dkk008. LC-D5, D50 68()(LA,LA3) LA 58 LA8 7(Di, Di3) 85(DF,DT) 88(DM,DR,DW,DL) c 50()(LA) 55(LA6-DK0) a LC- c a D500, D5000 3 0 D500 3 55 D5006, D50006 5 0 D5006 5 55 () With or contacts. () + mm with sealing cover. 7/98 998 Square D All Rights Reserved 6

D-Line Contactors, Overload Relays and Accessories Dimensions Contactors, types LC-D LP-D09, D, D8 Dimensions shown in millimeters (mm X.039 = inches) LP-D5, D3 = = Minimum electrical clearance 7 LA 77(Di) 90(Di) 97(3)(DF,DT) 05(3)(DM,DL) Minimum electrical clearance 8 LA 87(Di) 00(Di) 07(3)(DF,DT) 5(3)(DM,DL) 0 c c(la) c(la6-dk0) c3(la,la3),5 (LA8) 5,5 (LA8) 0 c c (LA) c(la6-dk0) c3(la,la3),5 (LA8) 56,5 (LA8) LP- c c c c c3 a LP- c c c c c3 a D09, D 6 8 60 68 D5 30 63 7 83 D8 5 65 73 D3 35 68 79 87 () With or contacts () With or contacts; contact: 57 (D5), 6 (D3) (LA-DN0 or DN0) () + mm with sealing cover () + mm with sealing cover (3) With or without combined use of a coil suppressor module (LA-DB, DC, DE). (3) With or without combined use of a coil suppressor module (LA-DB, DC, DE). LP-D0, D50, D65 Minimum electrical clearance LA-Di3 LP-D80 Minimum electrical clearance LA-Di3 7 7 7() 0()LA) 3(LA6-DK0) ()(LA,LA3) (3) 8() 0()(LA) (LA6-DK0) 9()(LA,LA3) (3) () With or contacts; contact: 96 (LA-DN0 or DN0) () With or contacts; contact: 0 (LA-DN0 or DN0) () + mm with sealing cover () + mm with sealing cover (3) 75: 3-pole, 85: -pole (3) 85: 3-pole, 96: -pole () 8: LP-Dkk008 () 96: LP-Dkk008 6 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Mounting Contactors, types LC-D and LP-D LC-D09 to D38, LP-D09 to D3 On mounting rail AM-DP00 or AM-DE00 (width 35mm) Dimensions shown in millimeters (mm X.039 = inches) LC-D0 to D95, LP-D0 to D80 On mounting rail AM-DL00 or DL0 (width 75 mm) For LC on mounting rail AM-EDkkk or AM-DE00 (width 35 mm) = b = 7 = c c LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 b 7 7 7 8 8 8 c (AM-DL00) 3 3 3 c (AM-DP00) 8 8 87 95 00 00 c (AM-DL0) 3 3 c (AM-DE00) 90 90 95 03 08 08 c (AM-EDkkk or DE00) 3 3 LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c (AM-DP00) 7 7 3 37 c (AM-DL00) 88 88 88 98 c (AM-DE00) 5 5 30 0 5 c (AM-DL0) 78 78 78 98 LC-D5, D50 On mounting rail AM-DP00 or AM-DE00 (width 35mm) = 00 = 58 = c LC- D500 D500 6 D5000 D5000 6 c (AM-DP00 or DR00) 3.5 7.5 3.5 7.5 c (AM-DEkkk or EDkkk).5 5.5.5 5.5 LC-D09 to D38, LP-D09 to D3 On mounting rail DZ5-MB and clip-on mounting plate LA9-D973 D09 to D8 LA9-D973 D5, D3 LA9-D973 LC-D0 to D95, LP-D0 to D80 On mounting rails DZ5-MB on 0 mm centers DZ5-ME5 c = 35 = = 0 5 50 5 9 5 50 5 = 0 0 c 5 0 LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 c 80 80 85 93 98 98 c 5 5 LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c 5 5 0 30 35 c 7 7 7 8 7/98 998 Square D All Rights Reserved 63

D-Line Contactors, Overload Relays and Accessories Mounting Contactors, types LC-D and LP-D LC-D09 to D38, LP-D09 to D3 On mounting rails DZ5-MB on 0 mm centres DZ5-ME5 Dimensions shown in millimeters (mm X.039 = inches) On mounting rails DZ5-MB on 60 mm centres DZ5-ME8 () 0 0 60 50 c 5 G c 7 LC- D09 D D8 D5 D3 D38 LC- D09 D D8 D5 D3 D38 a 5 5 5 57 57 57 c 80 80 85 93 98 98 c 80 80 85 93 98 98 G 35 35 35 LP- D09 D D8 D5 D3 LP- D09 D D8 D5 D3 a 5 5 57 57 57 c 5 5 0 30 35 c 5 5 0 30 35 G 35 35 35 0 or 50 0 or 50 () DX-AP5 (Lk-D09 to D8), DX-AP6 (Lk-D5 and D3) LC-D09 to D38, LP-D09 to D3 On pre-slotted mounting plate AM-PA, PB, PC AF-EA a LC-D0 to D95, LP-D0 to D80 On pre-slotted mounting plate AM-PA, PB, PC 50 0 c LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 c 80 80 85 93 98 98 c 5 5 G 35 35 35 LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c 5 5 0 30 35 c 7 7 7 8 G 35 35 35 0 or 50 0 or 50 LC-D09 to D38, LP-D09 to D8 Panel mounted with #8 screws G xm xø.5mm LP-D5 and D3 Panel mounted with #8 screws c LC-D0 to D95, LP-D0 to D80 Panel mounted with / screws 0 AF-EA6 3xØ6.5mm c = 50 = = G = = G = = 00/0 = c = 0 = LC- D09 D D8 D5 D3 D38 LC- D0 D50 D65 D80 D95 c 80 80 85 93 98 98 c 5 5 G 35 35 35 LP- D09 D D8 D5 D3 LP- D0 D50 D65 D80 c 5 5 0 30 35 c 7 7 7 8 G 35 35 35 50 50 LC-D5, D50 Panel mounted with / screws 30 = 58 c = = G = LC- D500 D5006 D5000 D50006 c 3 5 3 5 G (3-poles) 96/0 96/0 96/0 96/0 G (-poles) 30/ 30/ 6 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Dimensions, mounting Reversing contactors types LC-D and LP-D LC-D09 to D38 x LC-D09 to D38 Panel mounted with #8 screws b e Dimensions shown in millimeters (mm X.039 = inches) xø.5mm 50/60 = LP-D09 to D3 x LP-D09 to D3 Panel mounted with #8 screws b e xø.5mm 50/60 = = = c e = G = a c e = G = a LC- or x LC- a b c e (3 P) e ( P) G LP- or x LP- a b c e (3 P) e ( P) G D09, D 05 7 8 7 6 95 D09, D 05 7 9 7 6 95 D8 06 7 9 8 95 D8 06 7 7 8 95 D5 7 8 99 8 7 D5 7 8 36 8 7 D3, D38 7 8 7 0 D3 7 8 5 0 c, e and e including cabling c, e and e including cabling LC-D0 to D65 x LC-D0 to D65 Panel mounted with / screws b e 6xØ6.5mm = G = 00/0 8 x LP-D0 to D65 Panel mounted with / screws b e 6xØ6.5mm = G = 3 3 00/0 8 c e = 0 G 0 = c e = 0 G 0 = a a LC- or x LC- (3-pole) a b c e G G x LP- (3-pole) a b c e G G D0, D50, D65 65 7 5 50 90 D0, D50, D65 65 7 99 5 50 90 LC- or x LC- (-pole) a b c e G G x LP- (-pole) a b c e G G D0, D65 8 7 33 57 97 D0, D65 8 7 90 57 97 c, e and e including cabling c, e and e including cabling LC-D80 and D95 x LC-D80 and D95 Panel mounted with / screws b e 6xØ6.5mm = G = 00/0 8 x LP-D80 Panel mounted with / screws b e 6xØ6.5mm = G = 3 00/0 8 3 c e = 0 G 0 = a c e = 0 G 0 = a LC- or x LC- (3-pole) a b c e G G x LP- (3-pole) a b c e G G D80, D95 8 7 58 3 57 96 D80 8 7 5 3 57 96 LC- or x LC- (-pole) a b c e G G x LP- (-pole) a b c e G G D80 07 7 58 0 7 D80 07 7 5 0 7 c, e and e including cabling c, e and e including cabling c Dimensions with auxiliary contact blocks and add-on modules, see pages 6 and 6. 7/98 998 Square D All Rights Reserved 65

D-Line Contactors, Overload Relays and Accessories Dimensions, mounting Reversing contactors types LC-D and LP-D LC-D5 and D50 x LC-D5 and D50 Panel mounted with / screws Dimensions shown in millimeters (mm X.039 = inches) 58 e 30 = c e = G = a = LC- or x LC- (3-pole) a c e e G D5, D50 66 8 56 8 /56 LC- or x LC- (-pole) a c e e G D5 33 8-60 30/3 c, e and e including cabling 66 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Schemes Contactors, types LC-D and LP-D 3-pole contactors LC-D0900 to D300 LC-D500 and D5000 LC-D090 to D380 LP-D090 to D30 LC-D090 to D380 LP-D090 to D30 LC and LP- D0 to D95 -pole contactors LC and LP- D00 to D8000 LC-D500 LC and LP- D008 to D5008 LC and LP- D0008 to D80008 Front-mounting contact blocks Instantaneous auxiliary contacts N.O. LA-DN0 c N.C. LA-DN0 c N.O. + N.C. LA-DN N.O. LA-DN0 N.C. LA-DN0 N.O. + N.C. LA-DN N.O. + 3 N.C. LA-DN3 N.O. LA-DN0 N.C. LA-DN0 N.O. + N.C. including N.O. + N.C. make before break LA-DC 3 N.O. + N.C. LA-DN3 Front-mounting contact blocks Instantaneous auxiliary contacts conforming to standard EN 500 N.O. + N.C. LA-DNP N.O. + N.C. LA-DNG N.O. + N.C. LA-DNM N.O. + 3 N.C. LA-DN3P 3 N.O. + N.C. LA-DN3P N.O. + N.C. LA-DNP N.O. + N.C. LA-DNG N.O. + 3 N.C. LA-DN3M 3 N.O. + N.C. LA-DN3M N.O. + N.C. LA-DNM 3/NO /NC 3 3/NC 3/NO 3 3/NC /NC 5 53/NO 6 63/NO /NC 3 3/NC /NC 5 53/NO /NC 3 33/NO 3/NO 5 53/NO /NC 3 3/NC 3/NO 5 53/NO 3/NO /NC 3 3/NC 3/NO /NC 3 33/NO 3/NO /NC 3 3/NC /NC 3/NO /NC 3 33/NO 3/NC 5 5/NC 6 6/NC 7 7/NC 8 8/NC 5 53/NO 6 6/NC 76 75/NC 88 87/NO 5 53/NO 6 6/NC 7 73/NO 8 83/NO 5 5/NC 6 6/NC 5 53/NO 6 6/NC 7 7/NC 8 83/NO 5 53/NO 6 6/NC 7 7/NC 8 8/NC 5 53/NO 6 63/NO 7 73/NO 8 83/NO 3/NO (93) (9) /NC (9) (9) 5 53/NO 6 6/NC 5 53/NO 6 63/NO A T/ T/ T3/6 T/8 A R R A R R A A A /L 3/L 5/L3 7/L R R3 3 R 3 R3 A A T/ /L T/ 3/L T3/6 5/L3 A A T/ /L T/ 3/L T3/6 5/L3 3/NO A A T/ /L T/ 3/L T3/6 5/L3 /NC A A T/ /L T/ 3/L T3/6 5/L3 3/NO /NC c Single pole auxiliary contact blocks mounted on right-hand side of contactor. 7/98 998 Square D All Rights Reserved 67

D-Line Contactors, Overload Relays and Accessories Schemes Contactors, types LC-D and LP-D Front-mounting contact blocks Dust and damp protected instantaneous auxiliary contacts N.O. (-50 V) LA-DX0 N.O. (5- V) LA-DY0 Includes grounding terminal points N.O. protected (-50 V) N.O. standard LA-DZ0 N.O. protected (-50 V) + N.O. + N.C. normal LA-DZ3 Front-mounting contact blocks Time delay auxiliary contacts On-delay N.O. + N.C. LA-DTk Off-delay N.O. + N.C. LA3-DRk On-delay N.C. with N.O. break before make LA-DSk Mechanical latch blocks LA6-DK0 and LA6-DK0 Side-mounting contact blocks Instantaneous auxiliary contacts N.O. + N.C. LA8-DN N.O. LA8-DN0 5 53/NO (83) (8) 6 6/NC (7) (7) 5 53/NO (83) (8) 6 63/NO (73) (7) E A A E 56 55/NC 68 67/NO 58 57/NO 66 65/NC 56 55/NC 68 67/NO 5 53/NO 6 63/NO 5 53/NO 6 63/NO 5 53/NO 6 63/NO 7 73/NO 8 83/NO 5 53/NO 6 6/NC 7 73/NO 8 83/NO Electronic serial timer modules On-delay LA-DTkU Off-delay LA-DRkU LA-DMk Auto-Man-Stop control modules A A 0 c a K t A A A A c B 0 t K A A A A () B K c a A A c Programmable controller Interface modules Relay interface LA-DFk Relay interface LA-DFBQ Relay interface Relay interface with manual override switch LA-DLk Solid state LA-DWBk A c E + A E A c A c E + E A c A c E + E A c A c E + E A c K A A K A A K A A K A 68 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Schemes Contactors, types LC-D and LP-D Reversing contactors, horizontally mounted LC-D09 to D38, LP-D09 to D3 Reversing contactors, horizontally mounted LC-D0 to D95 Changeover contactors, horizontally mounted LC-D, LP-D Reversing contactors, horizontally mounted LC-D5 and D50 U V W L L L3 N A 6 6 A A A /L 3 /L 6 5 /L3 8 7 N /L 3 /L 6 5 /L3 8 7 N A A A 0 0 3 5 3 5 A 0 0 L L L3 U V W U V W A A 3 6 5 /NC 3 6 5 /NC A A A A 3 6 5 3/NO /NC 3 6 5 3/NO /NC A A L L L3 L L L3 Electrical interlocking of contactors with mechanical interlock with integrated electrical contacts LA9-Dkkk0 Electrical interlocking of contactors with mechanical interlock without integrated electrical contacts LA9-Dkkk78 A A 0 A A KM 0 0 0 0 KM KM KM KM Coil 0 0 KM Coil 0 KM A A KM KM A A A A A A KM A A 7/98 998 Square D All Rights Reserved 69

D-Line Contactors, Overload Relays and Accessories Scheme, setting-up, 3-pole bimetallic overload relays LR or LR3-D Scheme LR-D LR3-D 3 5 Reset { Auto Man. 6 96 95 97 98 Setting-up the special functions of LR-D and LR3-D thermal overload relays Setting the relay Manual-Automatic selection 7 6 3 6 7 5,5 TEST 8 A LR D 3 STOP M RESET A U T O 5 RESET A U T O RESET A U T O NO NC 98 97 95 96 k Lift the transparent cover to gain access to the settings and controls. k Adjustment is achieved by turning dial which is graduated directly in amperes. k The setting can be locked by sealing 3 of the cover. Stop function 5 Test function 6 Manual reset Automatic reset k After having lifted the transparent cover, the type of reset operation can be selected by turning the blue RESET selector : - turn to the left for manual reset, - push and turn to the right for automatic reset. The selector is then held in the automatic position and is released by turning the selector to the left (return to manual operation). k With the cover folded down, the selector is locked. k Manual resetting of the relay is achieved by pressing the blue RESET button. STOP ET A U T O RESET A U T O TEST Stop Locking Test Trip indicator k The Stop function is obtained by pressing the red STOP button 5. k Pressing the STOP button: -actuates the N.C. contact, - does not affect the N.O. contact. k The STOP button can be locked by fitting a U clip (ref. LA7-D90). With the cover folded down, the device is locked. k The Test function is obtained by pressing the red TEST button 6 with a screwdriver. k Operation of the TEST button simulates tripping of the relay and: - actuates both N.O. and N.C. contacts, - actuates the trip indicator 7. 70 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Characteristics 3-pole bi-metallic overload relays LR or LR3-D Application LR and LR3-D 3-pole bimetallic overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, long starting times and prolonged stalling of the motor. Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 97-, IEC 97-, NF C 63-650, VDE 0660, BS 9 Approvals E6353 CCN NKCR LR336 Class 3 03 LR D, D, D3: ASE, CSA, UL, DEMKO, NEMKO, FI, SEMKO, Sichere Trennung, PTB. LR-D: UL, CSA Degree of protection Conforming to VDE 006 Protection against direct finger contact Protective treatment Standard version TH Ambient air temperature around Storage - 60 to + 70 C (-76 to +58 F) the device Normal operation without derating (IEC 97-) - 30 to + 55 C (- to +3 F) Operational limits (with derating) - 0 to + 70 C (-0 to +58 F) Direct mounting Beneath the contactor LC-D, LP-D Operating positions without derating In relation to normal vertical mounting plane 90 80 90 90 90 80 Auxiliary contact characteristics Rated thermal current A 5 Maximum sealed consumption for operating coils of controlled contactors (Occasional operating cycles of contact 95-96) AC supply V 8 0 0 380 600 VA 00 00 00 600 600 600 V 8 0 0 0 DC supply W 00 00 50 5 5 Short-circuit protection By circuit breaker Select in accordance with NEC and local codes By fuses Maximum 00% of motor FLA Cabling Min./max. c.s.a. Flexible cable without cable end or conductors mm /.5 Flexible cable with cable end or conductors mm /.5 Solid cable without cable end or conductors mm /.5 Tightening torque. Nkm (0 lb.-in.) Minimum x 8 AWG Maximum x AWG 7/98 998 Square D All Rights Reserved 7

D-Line Contactors, Overload Relays and Accessories Characteristics 3-pole bi-metallic overload relays LR or LR3-D Electrical characteristics of power circuit Type LR-D LR3-D LR-D LR3-D LR-D3 LR3-D3 LR-D Conforming to IEC 97- V 690 690 000 000 Rated insulation voltage (Ui) Conforming to UL, CSA V 600 600 600 600 Rated impulse withstand voltage (Uimp) kv 6 6 6 6 Frequency limits Of the operational current Hz 0 to 00 0 to 00 0 to 00 0 to 00 Tripping class Conforming to UL 508, IEC 97-0 or 0 0 0 or 0 0 0 or 0 0 0 Setting range Depending on model A 0. to 5 3 to 0 7 to 0 80 to 0 Cabling Stranded cable without cable end or conductors Tightening torque Stranded cable with cable end Solid cable without cable end Operating characteristics or conductors or conductors AWG -8 mm.5/0 AWG 8 mm / AWG 8-8 mm /6.85 N m (5 lb.-in.) -8.5/0 8 /6-8.5/0.5 Nkm (5 lb.-in.) 0-0 /35 /35 0-8 /35 9 Nkm (5 lb.-in.) 0- /50 0- /35 0-0 /50 9 Nkm (5 lb.-in.) Reset Manual or automatic Selected by a switch, which can be locked and sealed, on the front face of the relay Indication On front face of relay Relay trip indicator Stop function Test function Tripping curves LR-D Average operating times depending on multiples of the current setting Relay can be locked in Stop position Accessed by pressing the Test button with a screwdriver Time Operating the Stop button: - actuates the N.C. contact, - does not affect the N.O. contact. Operating the Test button allows: - checking of control wiring, - simulation of relay ripping (actuates both N.C. and N.O. contacts). Class 0 Time Class 0 0 0 0 0 0 0 3 0,8 0,8 6 0 7 0 0 0 0 0 0 0 3 0,8 0,8 6 0 7 0 Balanced operation, 3-phase, from cold state. Balanced operation, -phase, from cold state. 3 Balanced operation, 3-phase, after a long period at the set current (hot state). 7 998 Square D All Rights Reserved 7/98

3-pole Solid-state Overload Relays LR9-D Scheme, setting-up Scheme LR9-D KM /L 3/L /T /T 6/T3 96 5/L3 98 6 3 5 L L L3 () Test Stop Reset man. % () (3) 95 97 A M 3 M KM 3 () Tripped N KM A A () () Overload (3) Setting current () Specialized circuit Setting up the special functions of the LR9-D solid state overload relay Setting the relay 7 07 90 LR9 D 5369 Ir(A) 7 50 protection électronique moteur ELECTRONIC MOTOR PROTECTION NO 98 97 NC 95 96 6 5 3 Lift the transparent cover (7) to gain access tot he various settings and controls. Adjustment is achieved by turning dial () which is graduated directly in amperes. The setting can be locked by sealing cover (7). Stop function (3) Test function () Stop Test Trip indicator The Stop function is obtained by pressing the red STOP button (3). Pressing the STOP button: - actuates the N/C contact, - does not affect the N/O contact. The STOP button can be locked by fitting a U clip (reference LA7-D90). The TEST function is obtained by pressing the red TEST button () with a screwdriver. Operation of the TEST button simulates tripping of the relay and: - actuates both the N/O and N/C contacts, - actuates the trip indicator (5). 7/98 998 Square D All Rights Reserved 73

3-pole Solid-state Overload Relays LR9-D Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 97-, 55-8, 55-7 and VDE 0660 Product vertifications E6353 CCN NKCR LR336 Class 3 03 UL 508, CSA -, PTB pending Degree of protection Conforming to VDE 006 IP X Protective treatment Standard version TH Ambient air temperature around the device (conforming to IEC 55-8) Storage C - 0 to +85 C (-0 to +85 F) Normal operation C - 0 to + 55 C (- to +3 F) Maximum operating altitude Without derating 000 m (6500 ft.) Operating positions without derating In relation to normal vertical mounting plane Any position Shock resistance Permissible acceleration conforming to IEC 68--7 5 g - ms Vibration resistance Permissible acceleration conforming to IEC 68--6 6 g Dialectric strength 50 Hz Conforming to IEC 55-5 kv 6 Impulse withstand voltage Conforming to IEC 55-5 kv 6 Resistance to electrostatic discharges Conforming to IEC 55-5 kv 8 Resistance to radio-frequency conducted disturbances Conforming to IEC 55-5 V/m 0 Resistance to fast transient currents Conforming to IEC 55-5 kv Electromagnetic compatibility Draft EN5008- and, EN5008- Meets requirements Auxiliary contact characteristics Rated thermal current A 5 Maximum sealed consumption for operating coils of controlled contactors (Occasional operating cycles of contact 95-96) AC supply V 8 0 0 380 600 VA 00 00 00 600 600 600 V 8 0 0 0 DC supply W 00 00 50 5 5 Short-circuit protection By circuit breaker Select in accordance with NEC and local codes By fuses Maximum 00% of motor FLA Cabling Min./max. c.s.a. Flexible cable without cable end or conductors mm /.5 Flexible cable with cable end or conductors mm /.5 Solid cable without cable end or conductors mm /.5 Tightening torque. Nkm (0 lb.-in.) Minimum x 8 AWG Maximum x AWG 7 998 Square D All Rights Reserved 7/98

3-pole Solid-state Overload Relays LR9-D Electrical characteristics of power circuit Type c Not for use with soft start units or variable speed controllers. LR9-D5369, LR9-D5569 Rated insulation voltage (Ui) Conforming to IEC 97- V 000 Rated insulation voltage (Ue) Conforming to VDE 00 gr C V 000 Rated impulse withstand voltage (Uimp) kv 8 Frequency limits Of the operational current Hz 50/60 c Tripping class Conforming to UL 508, IEC 97-0, 0A or 0 Setting range A 90 to 50 Cabling Tightening torque Operating characteristics Using DZFG lug AWG 6 to 3/0 Using LA9F03 terminal AWG 6 to 300 mcm Using DZFG lug Using LA9F03 terminal.5 Nkm (00 lb-in.) Nkm (00 lb-in.) with mm (5/3 in) Hex key Temperature compensation - 0 to + 70 C (- to +58 F) Reset Manual on front face of relay Fault indication On front face of relay Stop function Actuation of the N/C contact without affecting the N/O contact Test function On front face of relay Tripping thresholds Conforming to IEC 97-- A. ± 6% of In Sensitivity to phase failure Conforming to IEC 97-- Tripping in s ± 0% in the event of phase failure Setting (nominal motor current) By setting dial on front face of relay Sealing Yes Tripping curve LR9-D Average operating times depending on multiples of the current setting 00 0 0, 3 5 6 7 8 9 0 7/98 998 Square D All Rights Reserved 75

Selection 3-pole bi-metallic overload relays Class 0 c bi-metallic overload relays LRk-D Thermal overload relays - ambient compensated with manual or automatic reset - relay trip indicator - for AC or DC - with or without single-phase sensitivity LR-D3kk LR-D3kk LR-D33kk Short -circuit protection for North American applications Relay setting range European type fuses maximum rating By circuit breaker By fuses For direct mounting beneath contactor c Standard IEC 97- specifies a tripping time for 7. times the setting current I R : class 0: between and 0 seconds. Select in accordance with NEC and local codes Maximum 00% of motor FLA Catalog number am gg BS88 LC LP With single phase Without single phase A A A A sensitivity sensitivity kg (lb) 0.0 to 0.6 0.5 D09 to D38 D09 to D3 LR-D30 LR3-D30 0.65 (0.363) 0.6 to 0.5 0.5 D09 to D38 D09 to D3 LR-D30 LR3-D30 0.65 (0.363) 0.5 to 0.0 D09 to D38 D09 to D3 LR-D303 LR3-D303 0.65 (0.363) 0.0 to 0.63 D09 to D38 D09 to D3 LR-D30 LR3-D30 0.65 (0.363) 0.63 to D09 to D38 D09 to D3 LR-D305 LR3-D305 0.65 (0.363) to.6 6 D09 to D38 D09 to D3 LR-D306 LR3-D306 0.65 (0.363).6 to.5 6 0 D09 to D38 D09 to D3 LR-D307 LR3-D307 0.65 (0.363).5 to 6 0 6 D09 to D38 D09 to D3 LR-D308 LR3-D308 0.65 (0.363) to 6 8 6 6 D09 to D38 D09 to D3 LR-D30 LR3-D30 0.65 (0.363) 5.5 to 8 0 0 D09 to D38 D09 to D3 LR-D3 LR3-D3 0.65 (0.363) 7 to 0 0 0 D09 to D38 D09 to D3 LR-D3 LR3-D3 0.65 (0.363) 9 to 3 6 5 5 D to D38 D to D3 LR-D36 LR3-D36 0.65 (0.363) to 8 0 35 3 D8 to D38 D8 to D3 LR-D3 LR3-D3 0.65 (0.363) 7 to 5 5 50 50 D5 to D38 D5 and D3 LR-D3 LR3-D3 0.65 (0.363) 3 to 3 0 63 63 D5 to D38 D5 and D3 LR-D353 LR3-D353 0.30 (0.70) 30 to 0 0 80 80 D3 and D38 D3 LR-D355 LR3-D355 0.30 (0.70) 7 to 5 5 50 50 D0 to D95 D0 to D80 LR-D33 LR3-D33 0.50 (.) 3 to 3 0 63 63 D0 to D95 D0 to D80 LR-D3353 LR3-D3353 0.50 (.) 30 to 0 0 00 80 D0 to D95 D0 to D80 LR-D3355 LR3-D3355 0.50 (.) 37 to 50 63 00 00 D50 to D95 D50 to D80 LR-D3357 LR3-D3357 0.50 (.) 8 to 65 63 00 00 D50 to D95 D50 to D80 LR-D3359 LR3-D3359 0.50 (.) 55 to 70 80 5 5 D65 to D95 D65 and D80 LR-D336 LR3-D336 0.50 (.) 63 to 80 80 5 5 D80 and D95 D80 LR-D3363 LR3-D3363 0.50 (.) 80 to 0 00 60 60 D95 LR-D3365 LR3-D3365 0.50 (.) 80 to 0 5 00 60 D5 and D50 LR-D365 LR3-D365 0.900 (.98) 95 to 0 5 00 D5 and D50 LR-D367 LR3-D367 0.900 (.98) 0 to 0 60 50 00 D50 LR-D369 LR3-D369 0.900 (.98) Thermal overload relays for use on 000 V supplies For relays LR-D30 to LR-D3 only, for an operating voltage of 000 V and only for independent mounting, the reference becomes LR-D33kkA66. Example: LR3-D3 becomes LR-D33A66. Order an LA7-D306 terminal block separately, see pages 78 and 79. Weight 76 998 Square D All Rights Reserved 7/98

Selection - 3-pole bimetallic and solid state overload relays Class 0 q bi-metallic overload relays, LRk-D Thermal overload relays - ambient compensated with manual or automatic reset - relay trip indicator - for AC or DC - with or without single phase sensitivity LR-D5kk LR-D5kk Short -circuit protection for North American applications Relay setting range European type fuses maximum rating By circuit breaker By fuses For direct mounting beneath contactor Select in accordance with NEC and local codes Maximum 00% of motor FLA Catalog number am gg BS88 LC LP With single phase Without single phase A A A A sensitivity sensitivity kg (lb.).5 to 6 0 6 D09 to D3 D09 to D3 LR-D508 LR3-D508 0.90 (0.8) to 6 8 6 6 D09 to D3 D09 to D3 LR-D50 LR3-D50 0.90 (0.8) 5.5 to 8 0 0 D09 to D3 D09 to D3 LR-D5 LR3-D5 0.90 (0.8) 7 to 0 6 0 5 D09 to D3 D09 to D3 LR-D5 LR3-D5 0.90 (0.8) 9 to 3 6 5 5 D to D3 D to D3 LR-D56 LR3-D56 0.90 (0.8) to 8 5 35 0 D8 to D3 D8 to D3 LR-D5 LR3-D5 0.90 (0.8) 7 to 5 3 50 50 D5 and D3 D5 and D3 LR-D5 LR3-D5 0.90 (0.8) 3 to 3 0 63 63 D5 and D3 D5 and D3 LR-D553 LR3-D553 0.35 (0.759) 7 to 5 3 50 50 D0 to D95 D0 to D80 LR-D35 LR3-D35 0.535 (.79) 3 to 3 0 63 63 D0 to D95 D0 to D80 LR-D3553 LR3-D3553 0.535 (.79) 30 to 0 50 00 80 D0 to D95 D0 to D80 LR-D3555 LR3-D3555 0.535 (.79) 37 to 50 63 00 00 D50 to D95 D50 to D80 LR-D3557 LR3-D3557 0.535 (.79) 8 to 65 80 5 00 D50 to D95 D50 to D80 LR-D3559 LR3-D3559 0.535 (.79) 55 to 70 00 5 5 D65 to D95 D65 to D80 LR-D356 LR3-D356 0.535 (.79) 63 to 80 00 60 5 D80 and D95 D80 LR-D3563 LR3-D3563 0.535 (.79) Class 0 and 0 q solid state overload relays, LR9D Weight Thermal overload relays - ambient compensated and single phase sensitivity - trip indicator - for AC only - for direct mounting on contactor or independent panel mounting a LR-D35kk Short -circuit protection for North American applications Relay setting range European type fuses maximum rating am gg LC By circuit breaker By fuses For direct mounting beneath contactor Select in accordance with NEC and local codes Maximum 00% of motor FLA Catalog number Weight A A A kg (lb.) Class 0 q 90 to 50 60 50 D5 and 50 LR9-D5369 0.885 (.97) Class 0 q 90 to 50 00 50 D5 and 50 LR9-D5569 0.885 (.97) a Power terminals can be protected against direct finger contact by the addition of an LA9-F03 insulated terminal block, to be ordered separately (see page 79). q Standard IEC 97- specifies a tripping time for 7. times the setting current I R : Class 0: between and 0 seconds Class 0: between and 0 seconds 7/98 998 Square D All Rights Reserved 77

Selection overload relay accessories LA7-D06 DX-AP5 LA7-D305 LR-D LR-D LR3-D LA7-D03 R LA7-D03 LA7-D06 LA7-D90 DX-AP6 LR-D ZA-BZ3 LA7-D00 LR-D LR3-D ZA-BL3 LA7-D306 LA7-D90 LA7-D00 ZA-BZ3 ZA-BA639 78 LR-D3 LR3-D3 998 Square D All Rights Reserved 7/98

Selection overload relay accessories Accessories LRk-D (to be ordered separately) LA9-F03 Drawing of lug DXFG must be made Description For use with relays Sold in lots of Catalog number Terminal blocks for clip-on mounting on 35 mm DIN rail (AM-DP00) or for screw mounting. Power terminals adaptor for mounting an LRk-D3 overload relay beneath an LC-D0, D50 or D65 contactor Power terminals adaptor for mounting an LR-D3 overload relay beneath an LC-D5 or D50 contactor Mounting plates for screw mounting on.33 in. (0 mm) centers Weight kg (lb.) LR-D, LR3-D LA7-D06 c 0.00 (0.0) LR-D, LR3-D LA7-D06 c o.0 (0.6) LR-D3, LR3-D3 LA7-D306 c a 0.05 (0.5) LR-D3, LR3-D3 LA7-D058 0.080 (0.76) LR-D3 LA7-D3058 0.080 (0.76) LR-D, LR3-D 0 DX-AP5 q 0.065 (0.3) LR-D, LR3-D 0 DX-AP6 q 0.08 (0.80) LR-D3, LR3-D3 LA7-D90 q 0.30 (0.86) Marker holder snap-in LR-D, LR3-D, LR9-D 00 LA7-D903 0.00 (0.00) Bag of 00 labels (blank, self-adhesive) 0.76 x 0.630 in. (7 x 6 mm) LA9-D9 0.00 (0.00) Locking device for Stop button LR-D, LR3-D 0 LA7-D90 0.005 (0.0) Remote tripping and electrical reset device LR-D, LR3-D, LR9-D u LA7-D03 k f t 0.090 (0.98) IP0 Finger-safe terminal block for power cabling LR9-D LA9-F03 0.560 (.3) Extruded lugs for power cabling LR9-D LR9-D DZ-FG DZFG6 (pkg. of 6) Reset function By flexible cable (length =.6 ft., 0.5 m) LR-D, LR3-D, LR9-D LA7-D305 0.075 (0.65) Stop and/or Reset function For mounting, remove the terminal protection shrouds and order the following 3 products: Adaptor for door mounted operator LR-D, LR3-D, LR9-D LA7-D00 0.005 (0.0) Rod (snap-off end to obtain required length between.670 and.78 in., 7 and 0 mm) LR-D, LR3-D, LR9-D 0 ZA-BZ3 0.00 (0.0) Operating head for spring return pushbutton LR9-D LR-D, LR3-D ZA-BL3 (red) ZA-BA639 (blue) 0.0 (0.06) c Terminal blocks are supplied with terminals protected against direct finger contact and ready-to-tighten screws. a Add suffix 6 for terminals for ring type connectors. For example: LA7-D306 becomes LA7-D3066. q Remember to order the LA7-Dk06 terminal block corresponding to the overload relay size. f The time for which the coil of remote tripping and electrical resetting device LA7-D03 can remain energized depends on its rest time: s pulse duration with 9 s rest time; 5 s pulse duration with 30 s rest time; 0 s pulse duration with 90 s rest time; maximum pulse duration of 0 s with a rest time of 300s. Minimum impulse time: 00 ms. t Reference to be completed by adding the coil voltage code below. t Control circuit voltages Volts 8 96 0 0/30 380/00 5/0 50/60 Hz AC B E F M Q N Consumption, inrush and sealed: < 00 VA DC J B E DD F M Consumption, inrush and sealed: < 00 W. u For remote reset applications only when used with LR9Dkkkk solid state overload relays. 7/98 998 Square D All Rights Reserved 79

Dimensions 3-pole bi-metallic overload relays LR or LR3-D LR, LR3-D Mounting beneath contactors LC-D09 to D3, LP-D09 to D38 and LP-D AM-Dkkkk 35mm DIN rail AM-DP00 AM-DE00 d 9.5 b c c e g LC-D09, D, D8 8 98 50 0 e LC-D5 86 08 55 0.7 b LC-D3, D38 86 09 55 8. 7 () LP-D09, D, D8 8 33 50 0 9 c d 8 7 g LP-D5 86 5 55 0.7 LP-D3 86 53 55 8. LP-D 8 98 50 0 c + 5 mm for LR-D5kk LR, LR3-D Direct mounting beneath contactors LC-D5 to D38, LP-D5 and D3 35mm DIN rail AM-DP00 AM-DE00 AM-Dkkkk d 9.5 b c e g LC-D5 97.5 98 60.5 LC-D3, D38 97.5 98 60 0.5 e LP-D5 97.5 55 60.5 b LP-D3 97.5 55 60 0.5 59 9 c d 3 5 g LR, LR3-D3 Direct mounting beneath contactors LC-D0 to D95 and LP-D0 to D80 AM-DLkkk 75mm DIN rail AM-DL0 AM-DL00 d 7 7 e b c e g (3P) g (P) LC-D0 9 7..5 3 LC-D50 9 7..5 LC-D65 9 7..5 3 LC-D80 5.5 76.9 9.5 b LC-D95 5.5 76.9 9.5 LP-D0 76 7..5 3 5 LP-D50 76 7..5 09 c d 30 70 g LP-D65 76 7..5 3 LP-D80 5.5 79. 76.9 9.5 80 998 Square D All Rights Reserved 7/98

Dimensions 3-pole bimetallic and solid-state overload relays LR -D LR-D bimetallic overload relay Direct mounting beneath contactors LC-D5 and D50 3 d 0 35mm DIN rail dimensions AM-DP00 and DR00 AM-DEkkk and EDkkk d.5 0.5 LR9-D solid-state overload relay Direct mounting beneath contactors LC-D5 and D50 7 36 55 89 50 67 3 d 0 35mm DIN rail dimensions AM-DP00 and DR00 AM-DEkkk and EDkkk d.5 0.5 7/98 998 Square D All Rights Reserved 8

Mounting 3-pole bi-metallic overload relays LR or LR3-D LR, LR3-D Independent mounting on 50 mm centers or on 35mm wide DIN rail AM-DP00 or DE00 5 LA7-D06 = 35 = Independent mounting on 0 mm centers LA7-D06 Dimensions shown in millimeters (mm X.039 = inches) = 6 = 3.5 79 50/60() 5 0 = 98 d xø.5 8 7 35mm wide DIN rail dimensions AM-DP00 AM-DE00 08 DX-AP5 xø6.5 = d 9.5 () + 5 mm for LR-D5kk LR, LR3-D3, LR9D Remote trip or electrical reset device LA7-D03 c 96 9 () Can be mounted on RH or LH side of relays LR, LR3-D LR, LR3-D Independent mounting on 50 mm centers or on 35mm wide DIN rail AM-DP00 or DE00 55 LA7-D06 = 0 = Independent mounting on 0 mm centers LA7-D06 = 57 = 3.5 90 3 50/60 0 = 98 d xø.5 3 35mm wide DIN rail dimensions 08 AM-DP00 AM-DE00 d 9.5 Remote tripping or electrical reset device = 5 DX-AP6 xø6.5 LA7-D03 c 96 9 c Can be mounted on RH or LH side of relays LR, LR3-D 8 998 Square D All Rights Reserved 7/98

Mounting 3-pole bi-metallic and solid-state overload relays LRk-D LR, LR3-D Independent mounting on 50 mm centers or on 35mm wide DIN rail AM-DP00 or DE00 75 LA7-D306 = 50 = Independent mounting on 0 mm centers LA7-D306 LA7-D90 Dimensions shown in millimeters (mm X.039 = inches) = 75 = 5.5 00 75/87 6 3xØ6.5 0 d xø.5 3 3.5 3 = 0 = 35mm wide DIN rail dimension AM-DP00 AM-DE00 d 9.5 () + 5 mm for LR-D5ii LR, LR3-D3, LR9D Remote trip or electrical reset LA7-D03 c 9 c Can be mounted on RH or LH side of relays LR, LR3-D. For mounting on RH side of LR9D only for remote reset applications. Will not mount on LH side of LR9D for remote tripping applications. 7/98 998 Square D All Rights Reserved 83

Mounting 3-pole bi-metallic and solid-state overload relays LA7-D00 Adaptor for door mounted operator Stop Reset c 0 Dimensions shown in millimeters (mm X.039 = inches) c: adjustable from 7 to 0 mm LA7-D00 LA7-D305 Reset by flexible cable Mounting with cable straight Mounting with cable bent LA7-D305 e c e M0x c: up to 550 mm e: up to 0 mm e: up to 0 mm 8 998 Square D All Rights Reserved 7/98

Low consumption contactors LP-D contactors and LP5-D reversing contactors operate on a low-level DC supply. Their low consumption operating coil allows direct control from solid state outputs without the need for additional interface modules or interposing relays in the control circuit. They are available in versions: LP-D0 Contactors with standard low consumption coil. Contactors with low consumption coil with bidirectional peak limiting diode for built-in suppression. This version provides a perfect working combination between power and electronic circuits. Contactors with wide range low consumption coils, allowing correct operation between 0.7 and.5 of the control voltage Uc. These are essential where solid state components are connected in series with the control circuit or on machines based on special-purpose electronic cards. Contactors LP-D and LP5-D can be used for the control of motors in category AC-3 up to 5 A (5 hp at 60 VAC). Contactors with wide range low consumption coils with built-in suppression as standard via bidirectional peak limiting diode, allowing correct operation between 0.7 and.5 of the control voltage (Uc). Benefits Low heat dissipation: allowing higher component density in control panels. Use on battery supplies: for on-board equipment, use on battery supply allows easy backup and independent supply shared with programmable controllers. Thermal protection: Telemecanique bi-metallic overload relays can be used with these low consumption contactors. Uniform design: low consumption contactors are the same size as standard contactors LC-D09 and LC-D. Variable composition: low consumption contactors can be fitted with special front-mounting auxiliary blocks. LP-D contactors can also be fitted with electronic serial timer modules LA-DT and Auto-Man- Stop interface modules LA-DM. + DC supply Programmable Logic Controller Printed Circuit Board CA-D LC-F LP5-D LP-D LR9F LR-D LR-D 7/98 998 Square D All Rights Reserved 85

Characteristics - Low consumption contactors LP-D and LP5-D Environment Conforming to standards Meets the essential requirements of the LV & EMC directives IEC 58-, 55-, 337-, 97- and 97-, VDE 0660, NF C 63-0 and 5-50, BS 5, JIS C835, JEM 038 Approvals E686 CCN NLDX LR336 Class 3 0 ASE, UL, CSA, DEMKO, NEMKO, SEMKO, FI Protective treatment Standard version TH Degree of protection Conforming to VDE 006 Protection against direct finger contact Maximum operating altitude Without derating 3000m (9800 ft.) Ambient air temperature around the device Storage - 0 to + 80 C (-0...+76 F) Operating positions for ambient temperature 55 C (3 F) Operation (0.8 to. Uc) For operation at Uc Without derating in the following positions - 5 to + 55 C (+3...+3 F) - 5 to + 70 C (-3 to +58 F) 30 80 30 90 90 Power pole cabling Tightening torque Stranded cable without cable end Stranded cable with cable end Solid cable without cable end Control connections Power connections conductor conductors LPk-D AWG 7 to 7 to LPk-D8 mm to to LPk-D5 AWG 6 to 0 mm.5 to 6 6 to 0.5 to 6 LPk-D AWG 7 to 7 to LPk-D8 mm to to LPk-D5 AWG 7 to 0 mm to 6 7 to to LPk-D AWG 7 to 7 to LPk-D8 mm to to LPk-D5 AWG 6 to 0 mm.5 to 6. Nkm (0 lb.-in.). Nkm (0 lb.-in.) 6 to 0.5 to 6 86 998 Square D All Rights Reserved 7/98

Characteristics - Low consumption contactors LP-D and LP5-D Control circuit characteristics Rated insulation voltage Conforming to VDE D0 (group C) V 50 Conforming to IEC 58-, BS 5 V 50 Conforming to CSA C- n V 300 Maximum voltage Of the control circuit, a V 7 Shock resistance c / sine wave ms Vibration resistance c 5 to 300 Hz Average consumption DC supply Operating time a at Uc and at 68 F (0 C) Contactor open Contactor closed Contactor open Contactor closed Standard coil (0.8 to. Uc) Wide range coil (0.7 to.5 Uc) C O c Without change of contact state, in the least favorable direction. a Closing time C is measured from the moment the coil supply is switched on to initial contact of the main poles. Opening time O is measured from the moment the coil supply is switched off to the moment the main poles separate. 0 gn gn 5 gn 0 gn Inrush Sealed LPk-D W.. LPk- D8 W.6.6 LPk-D5 W LPk-D W.6.6 LPk-D8 W LPk-D5 W.. LPk-D ms 60 LPk-D8 ms 50 LPk-D5 ms 60 LPk-D ms 5 LPk-D8 ms 5 LPk-D5 ms 5 Operational 0.8 to. Uc Control circuit voltage limits θ 3 F, (55 C) Drop-out 0. to 0.3 Uc Time constant (L/R) ms 0 Mechanical life LP-Dkk 30 In millions of operating cycles (mechanical durability) LP5-Dkk 0 Maximum operating rate At ambient temperature 3 F (55 C) Op cycs/h 3600 7/98 998 Square D All Rights Reserved 87

Characteristics - Low consumption contactors LP-D and LP5-D Pole characteristics Rated insulation voltage Conforming to VDE 00 C V 750 To IEC 58-, 97-, BS 5, NF C 0-00 V 690 Conforming to CSA C - n, UL 508 V 600 Rated impulse withstand voltage (U imp) kv 8 Conventional rated thermal current (Ith) For θ 0 F (0 C) LPk-D A 0 LPk-D8 A 5 LPk-D5 A 0 Frequency limits Hz 5 to 00 Rated operational voltage (Ue) V 690 Rated making capacity Conforming to IEC 58- LPk-D A 30 and IEC 97- LPk-D8 A 300 LPk-D5 A 30 Rated breaking capacity Conforming to IEC 58- and IEC 97- V 0 380 5 0 500 660/690 I rms LPk-D A 30 30 30 30 75 85 LPk-D8 A 300 300 300 300 50 0 LPk-D5 A 30 30 30 5 350 50 Permissible short time rating In free air, for s 5 s 0 s 30 s min 3 min 0 min from cold state (θ 0 F, 0 C) LPk-D A 0 30 05 76 6 30 LPk-D8 A 0 85 5 05 8 58 0 LPk-D5 A 380 80 0 55 0 80 50 Pole impedance At 50 Hz, at Ith mω 3 Operation in category AC- Maximum operational current θ 0 F (0 C) θ 3 F (55 C) (resistive circuits, heating, lighting) LPk-D A 0 6 LPk-D8 A 5 0 LPk-D5 A 0 3 Rated operational power, V 0/30 380/00 5 0 500 660/690 depending on voltage 50 or 60 Hz 3-phase LPk-D kw 8 3 5 7 3 LPk-D8 kw 9 5 7 8 0 7 LPk-D5 kw 5 7 9 33 3 Increase in operational thermal current by parallel poles in parallel : k =.6 connection of poles. Apply these coefficients to the maximum currents above. The coefficients take into account the often unbalanced current distribution between poles. Use connecting links to connect poles 3 poles in parallel : k =.5 in parallel. Operation in category AC-3 Rated operational power, depending V 0/30 380/00 5 0 500 660/690 (squirrel cage motors) on voltage 50 or 60 Hz 3-phase. LPk-D kw 3 5.5 5.5 5.5 7.5 7.5 Standard motor power ratings LPk-D8 kw 7.5 9 9 0 0 LPk-D5 kw 5.5 5 5 Motor power ratings conforming to UL, CSA V 30 60 600 LPk-D hp 3 7.5 0 LP-D8 hp 5 0 5 LP5-D8 hp 5 0 0 LP-D5 hp 5 5 0 LP5-D5 hp 5 5 5 Maximum operating rate (in cycles/hour) depending On-load factor Operational power Cycles/hour on the % of the rated operational power P 85 % P 00 85 % 0.5 P 3000 5 % P 800 Short circuit protection By circuit breaker Select in accordance with NEC and local codes By fuses Maximum 0% of motor FLA 88 998 Square D All Rights Reserved 7/98

Characteristics - Low consumption contactors LP-D and LP5-D Electrical life Utilization category AC- and operational voltage <0 V LP -D LP -D8 Millions of operating cycles LP -D5 3 0,8 0,6 0, 0, 0, 3 5 6 7 8 9 0 5 0 5 30 0 Current broken in A Utilization category AC-3 and operational voltage < 0 V Millions of operating cycles LP -D LP -D8 LP -D5 3.5,5.5,5 3 5 6 7 8 9 0 5 8 0 5 30 0 50 Current broken in A 7/98 998 Square D All Rights Reserved 89

References Low consumption contactors Kilowatt ratings for international applications 3-pole contactors for Finger-safe terminals for power cabling Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operational current in AC-3 0 V up to Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q Weight kw kw kw kw kw kw A A N/O N/C DIN rail or mounting c kg (lb.) LP-D0BD LP-D090kk(k) 0.35 (0.693). 5.5 5.5 9 0 LP-D090kk(k) 0.35 (0.693) LP-D0kk(k) 0.35 (0.693) 3 5.5 5.5 5.5 7.5 7.5 0 LP-D0kk(k) 0.35 (0.693) LP-D80kk(k) 0.30 (0.70) 7.5 9 9 0 0 8 5 LP-D80kk(k) 0.30 (0.70) 5.5 5 5 5 0 LP-D500kk(k) 0.355 (0.78) c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC 5 8 7 Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC 5 8 7 Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable. 90 998 Square D All Rights Reserved 7/98

Horsepower ratings for North American applications 3-pole contactors for Finger-safe terminals for power cabling References Low consumption contactors Maximum horsepower rating -phase 50/60Hz 3-phase 50/60Hz Maximum inductive current in AC-3 category Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q Weight LP-D0BD 5V 0V 30V 0V 00V 08V 0V 0V 60V 80V 600V N/O N/C hp hp hp hp hp hp A A DIN rail or mounting c kg (lb.) 0.5 5 7.5 9 0 3 3 7.5 0 0 LP-D090kk(k) 0.35 (0.693) LP-D090kk(k) 0.35 (0.693) LP-D0kk(k) 0.35 (0.693) LP-D0kk(k) 0.35 (0.693) LP-D80kk(k) 0.30 (0.70) 3 5 5 0 5 8 5 LP-D80kk(k) 0.30 (0.70) 3 7.5 7.5 5 0 5 0 LP-D500kk(k) 0.355 (0.78) c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC 5 8 7 Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC 5 8 7 Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable. 7/98 998 Square D All Rights Reserved 9

References Low consumption reversing contactors Pre-assembled, horizontally mounted, pre-wired power connections Kilowatt ratings for international applications 3-pole reversing contactors for Finger-safe terminals for power cabling Pre-wired power connections Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0V 30V 380V 00V 5V 0V 500V 660V 690V Rated operational current in AC-3 0 V up to Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q Weight LP-D0BD kw kw kw kw kw kw A A N/O N/C DIN rail or mounting c kg (lb.). 5.5 5.5 9 0 LP5-D090kk(k) 0.670 (.7) 3 5.5 5.5 5.5 7.5 7.5 0 LP5-D0kk(k) 0.670 (.7) 7.5 9 9 0 0 8 5 LP5-D80kk(k) 0.680 (.96) 5.5 5 5 5 0 LP5-D500kk(k) 0.770 (.69) c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC 5 8 7 Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC 5 8 7 Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable. 9 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Selection Low consumption reversing contactors Pre-assembled, horizontally mounted, pre-wired power connections Horsepower ratings for North American applications 3-pole reversing contactors with Finger-safe terminals for power cabling LP5-D0BD Maximum horsepower rating -phase 50/60Hz 3-phase 50/60Hz 5V 0V 30V 0V 00V 08V 0V 0V 60V 80V 600V Maximum inductive current in AC-3 category Maximum operational current in AC- θ 55 C Instantaneous auxiliary contact Catalog number. Complete with code indicating control circuit voltage a q hp hp hp hp hp hp A A DIN rail or mounting c kg (lb.) 0.5 5 7.5 9 0 LP5-D090kk(k) 0.670 (.7) 3 3 7.5 0 0 LP5-D0kk(k) 0.670 (.7) 3 5 5 0 5 8 5 LP5-D80kk(k) 0.680 (.96) 3 7.5 7.5 5 0 5 0 LP5-D500kk(k) 0.770 (.69) Weight c Clip-on mounting on 35 mm DIN rail AM-DP or screw mounting. Power terminals: protected against direct finger contact and ready-to-wire terminals a Coil selection Standard coils (0.8 to. Uc) q Volts AC 5 8 7 Code AD JD BD ED SD Coils fitted with integral bidirectional peak limiting diode suppressor (0.8 to. Uc) q Volts AC 5 8 7 Code AD3 JD3 BD3 ED3 SD3 Wide range coils (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW EW SW Wide range coils fitted with integral bidirectional peak limiting diode suppressor (0.7 to.5 Uc) q Volts AC 8 7 Operating range 7 to 30 V 3 to 60 V 50 to 90 V Code BW3 EW3 SW3 q Coil not interchangeable. 7/98 998 Square D All Rights Reserved 93

D-Line Contactors, Overload Relays and Accessories Selection Accessories for low consumption contactors LA9-D6 LA-DMK LA9-D60 LA9-D6 LA-DT LA9-D63 LP5-D LP-D LA9-D9 LN-DN LA9-D90 LA9-D93 LA9-D9 LR-D 9 998 Square D All Rights Reserved 7/98

Type LPk-D Accessories (to be ordered separately) Instantaneous auxiliary contact blocks D-Line Contactors, Overload Relays and Accessories Selection Accessories for low consumption contactors Front clip-on mounting on Number of contacts Composition Catalog number Weight N/O N/C kg (lb.) LP, LP5 LN-DN 0.030 (0.066) Electronic serial timer modules Type Time delay For use on Operational voltage c Catalog number Weight kg (lb.) 0. to s LP, LP5 AC /7 V LA-DT0U 0.00 (0.088) On-delay.5 to 30 s LP, LP5 AC /7 V LA-DTU 0.00 (0.088) 5 to 500 s LP, LP5 AC /7 V LA-DTU 0.00 (0.088) Auto-Man-Stop control module For local override operation tests For use on Operational voltage Catalog number Weight kg (lb.) With O-I switch and -position Auto-Man switch LP, LP5 AC /7 V LA-DMK 0.00 (0.088) 3-pole bi-metallic overload relays Compensated, with manual or automatic reset For mounting beneath contactor Relay setting range Type Catalog number Weight kg (lb.) LP or LP5 Accessories 0. to 0.6 A up to 7 to 5 A With single-phase sensitivity LR-Dkkk a 0.65 (0.363) Without single-phase sensitivity LR3-Dkkk a 0.65 (0.363) Description For use on Sold in lots of Catalog number Weight kg (lb.) Connector for cable connection c For V operation, the contactor must have a V wide range coil (code BW). a Basic reference, to be completed: see page 76 and 77. -pole, 0 mm LPk-D09, D, D8 LA9-D60 0.030 (0.066) 3-pole, 5 mm LPk-D5 LA9-D360 0.00 (0.088) poles LP-D09, D, D8 0 LA9-D6 0.0 (0.06) Paralleling links for 3 poles LP-D09, D, D8 0 LA9-D6 0.003 (0.007) poles LP-D09, D, D8 LA9-D63 0.0 (0.053) 8 x mm clip-in legend holder LP, LP5 00 LA9-D9 0.00 (0.00) 8 x 7 mm clip-in legend holder LN-DN 00 LA9-D90 0.00 (0.00) Bag of 300 blank, self-adhesive legend plates - 7 x mm Marker holder LA9-D9 LA9-D93 0.00 (0.00) Bag of 00 blank, self-adhesive legend plates - 7 x 6 mm Marker holder LA9-D90 LA9-D9 0.00 (0.00) 7/98 998 Square D All Rights Reserved 95

D-Line Contactors, Overload Relays and Accessories Characteristics - Low consumption contactors type LP-D Auxiliary contact blocks Type LP, LP5 LN-DN Instantaneous auxiliary contact characteristics (add-on or integral) Number of contacts (LP-D09, D, D8) Rated operational voltage Conforming to IEC 97-5; up to V 690 690 Rated insulation voltage (Ui) Conforming to IEC 97-5 V 690 690 Conforming to UL, CSA V 600 600 Rated thermal current (Ith) For ambient temperature 0 C A 0 6 Minimum switching capacity U V 7 7 I ma 5 5 Short-circuit protection To IEC 97-5- and VDE 0660. gg fuse. Rated making capacity (rms) Conforming to IEC 97-5- A 0 80 Permissible short time rating For s A 00 0 500 ms 0 60 00 ms 0 80 Insulation resistance MΩ > 0 > 0 Non-overlap time Guaranteed between N.C. and N.O. contacts ms,5 Mechanical durability In millions of operating cycles 30 30 Breaking limit of contacts for: a maximum of 50 operating cycles, at 0 s intervals (power broken = making power x ϕ 0.7). Electrical durability of contacts: - for million operating cycles (a), - for 3 million operating cycles (b), - for 0 million operating cycles (c). 3 Breaking limit of contacts for: a maximum of 0 operating cycles, at 0 s intervals and with current passing for 0.5 s per operating cycle. Thermal limit. AC supply, categories AC- and AC-5 Power broken in VA 5 000 0 000 8000 6000 000 000 000 800 600 00 00 00 80 60 50 8 0 0 380 660 V a b c DC supply, category DC-3 Power broken in W 500 000 800 600 00 50 00 0 00 50 0 00 00 80 60 0 0 0 8 6 8 0 0 380 500 5/7 0 660 V a b c 96 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Dimensions, mounting Low consumption contactors and reversing contactors Type LPk-D Dimensions shown in millimeters (mm X.039 = inches) Dimensions LP-D LP5-D 0 c 0 c b b (LA-DT) b (LA-DM) b b (LA-DT) b (LA-DM) c (LN-DN) 5 c (LN-DN) 03 b b b c c b b b c c LP-D09, D, D8 7 97 0 78.5 LP5-D09, D, D8 7 97 0 78.5 LP-D5 76 99 06 87 0 LP5-D5 76 99 06 87 0 Mounting LP-D LP5-D on rail AM-D00 on panel with #8 screws on rail AM-D00 on panel xø5 xø5 = = = 60 = = = 60 = = c = 35 = c = 9 = LPk-D09 LPk-D LPk-D8 LPk-D5 AM-DP00 80.5 80.5 80.5 89. AM-DE00 88 88 88 96.6 Mounting of contactors LP, LP5-D09, D & D8 with bi-metallic overload relay LRk-D Mounting of contactors LP, LP5-D5 with bi-metallic overload relay LRk-D 7 7 8 8 50 5 9 97 d 7 8 9 97 d 7 8 35mm wide DIN rail dimension 35mm wide DIN rail dimension d d AM-DP00 AM-DP00 AM-DE00 9.5 AM-DE00 9.5 7/98 998 Square D All Rights Reserved 97

D-Line Contactors, Overload Relays and Accessories Schemes - Low consumption contactors and reversing contactors Type LPk-D Contactors LP-Dkk0 3P + N.O. LP-Dkk0 3P + N.C. LP-D500 3P Reversing contactors LP5-Dkk0 3P + N.O. LP5-D500 3P U V W U V W A 6 6 A A 6 6 A A 3 5 3 3 5 3 A A 3 5 3 5 A L L L3 L L L3 A A T/ /L T/ 3/L T3/6 5/L3 3/NO A A T/ /L T/ 3/L T3/6 5/L3 /NC A A T/ /L T/ 3/L T3/6 5/L3 LP5-D09-D-D8 Integral electrical interlocking of the contactors Add-on auxiliary contact block LN-DN N.C. + N.O. A A A A K K 53/NO 5 6 /NC K K 98 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Schemes - Low consumption contactors and reversing contactors STANDARD CONTACTORS Capacitors, together with the circuits to which they are connected, form oscillatory circuits which can, at the moment of switch-on, give rise to high transient currents (> 80 In) at high frequencies ( to 5 khz). As a general rule, the peak current on energization is lower when: the mains inductances are high, the line transformer ratings are low, the transformer short-circuit voltage is high, the ratio between the sum of the ratings of the capacitors already switched into the circuit and that of the capacitors to be switched in is small (for multiple step capacitor banks). In accordance with standards IEC 70, NF C 5-00, VDE 0560, the switching contactor must be able to withstand a continuous current of.3 times the rated current of the capacitor bank step being switched. The rated operational powers given in the tables opposite take this overload into account. Short-circuit protection is normally provided by gl type HRC fuses rated at.7 to In. CONTACTOR APPLICATIONS Operating conditions Capacitors are directly switched. The values of peak current at switch-on must not exceed the values indicated opposite. An inductor may be inserted in each of the three phases supplying the capacitors to reduce the peak current, if necessary. Inductance values are determined according to the selected operating temperature. Power factor correction by a single-step capacitor bank The use of a choke inductor is unnecessary : the inductance of the mains supply is adequate to limit the peak to a value compatible with the contactor characteristics. Power factor correction by a multiple-step capacitor bank Select a special contactor as defined on page. If a standard contactor is used, it is essential to insert a choke inductor in each of the three phases of each step. 7/98 998 Square D All Rights Reserved 99

D-Line Contactors, Overload Relays and Accessories Selection guide for switching three phase capacitors International applications only Capacitor switching Capacitors, together with the circuits to which they are connected, form oscillatory circuits which can, at the moment of switch-on, give rise to high transient currents (> 80 In) at high frequencies ( to 5 khz). As a general rule, the peak current on energisation is lower when: - the mains inductances are high, - the line transformer ratings are low, - the transformer short-circuit voltage is high, - the ratio between the sum of the ratings of the capacitors already switched into the circuit and that of the capacitors to be switched in is small (for multiple step capacitor banks). In accordance with standards IEC 70, NF C 5-00, VDE 0560, the switching contactor must be able to withstand a continuous current of.3 times the rated current of the capacitor bank step being switched. The rated operational powers given in the tables opposite take this overload into account. Short-circuit protection is normally provided by gl type HRC fuses rated at.7 to In. E686 CCN NLDX LR336 Class 3 0 Contactor selection Operating conditions Capacitors are directly switched. The values of peak current at switch-on must not exceed the values indicated on the following page. Inductors may be inserted in each of the three phases supplying the capacitors to reduce the peak current, if necessary. Inductance values are determined according to the selected operating temperature. Power factor correction by a single-step capacitor bank The use of a choke inductor is unnecessary: the inductance of the mains supply is adequate to limit the peak to a value compatible with the contactor characteristics. Power factor correction by a multiple-step capacitor bank Select a special contactor as defined on page. If a standard contactor is used, it is essential to insert a choke inductor in each of the three phases of each step. 00 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Selection guide for switching three phase capacitors Maximum operational power of contactors: International applications only Standard contactors Maximum operating rate: 0 operating cycles/hour. Electrical durability at maximum load: 00 000 operating cycles. With choke inductors connected, where necessary. Operational power at 50/60 Hz c Upper limit of temperature category conforming to IEC 70. Maximum peak current Contactor θ 0 F (0 C) c θ 3 F (55 C) c 0 V/0 V 00 V/0 V 600 V/690 V 0 V/0 V 00 V/0 V 600 V/690 V kvar kvar kvar kvar kvar kvar A 6 5 6 5 560 LC-D09, D 9 5 0 9 5 0 850 LC-D8 0 5 0 5 600 LC-D5 5 30 5 30 900 LC-D3 7 30 37 7 30 37 60 LC-D0 0 50 0 50 60 LC-D50 0 50 0 50 300 LC-D65 35 60 75 35 60 75 300 LC-D80, D95 50 90 5 37.5 75 80 300 LC-F5 60 0 35 0 85 90 300 LC-F50 70 5 60 50 00 00 3500 LC-F85 80 0 90 60 0 0 000 LC-F5 90 60 5 75 5 5 5000 LC-F65 00 90 75 85 0 65 6500 LC-F330 5 0 300 00 60 00 8000 LC-F00 80 300 00 5 0 300 0 000 LC-F500 50 00 600 90 350 500 000 LC-F630 00 350 500 80 350 500 5 000 LC-BL 300 550 650 50 500 600 5 000 LC-BM 500 850 950 00 750 750 5 000 LC-BP 600 00 300 500 000 000 5 000 LC-BR 7/98 998 Square D All Rights Reserved 0

D-Line Contactors, Overload Relays and Accessories Contactors for capacitor switching LC-DkK: International applications only Special contactors Special contactors LC-DkK are designed for switching 3-phase, single or multiple-step capacitor banks; they conform to standards IEC 70 and 83, NFC 5-00, VDE 0560. Contactor applications Specification LC-DFKkk Contactors fitted with a block of early make poles and damping resistors, limiting the value of the current on closing to 60 In max. This current limitation at switch-on increases the life of all the components in the installation, in particular that of the fuses and capacitors. The patented design of the add-on block (n 90 9-0) guarantees the safety and long life of the installation. Operating conditions There is no need to use choke inductors for either single or multiple-step capacitor banks. Short-circuit protection must be provided by gi type fuses rated at.7 to In. Maximum operational power The power values given in the selection table below are for the following operating conditions Prospective peak current at switch-on LC-DkK 00 In Maximum operating rate LC-DFK, DGK, DLK, DMK, DPK 0 operating cycles/hour. LC-DTK, DWK 00 operating cycles/hour. Electrical durability at rated load Operational power at 50/60 Hz θ 3 F, 55 C a 0 V 00 V 660 V LC-DFK, DGK 00 V 300 000 operating cycles. LC-DLK, DMK, DPK, DTK, DWK 690 V 00 000 operating cycles. Instantaneous auxiliary contacts Tightening torque on cable end of power tterminals Basic reference. Complete with code indicating control circuit voltage c Weight 0 V 0 V 690 V kvar kvar kvar N.O. N.C. lb-in (N m) lb (kg) 6.7.5 8 0.66 (.) LC-DFKkk 0.98 (0.30) 0.66 (.) LC-DFK0kk 0.98 (0.30) 8.5 6.7 5.0 (.7) LC-DGKkk 0.99 (0.50) 5.0 (.7) LC-DGK0kk 0.99 (0.50) 0 0 30 6.88 (.9) LC-DLKkk.3 (0.600) 6.88 (.9) LC-DLK0kk.3 (0.600) 5 5 36. (.5) LC-DMKkk.389 (0.630). (.5) LC-DMK0kk.389 (0.630) 0 33.3 8. (5) LC-DPKkk.866 (.300) 5 0 58. (5) LC-DTKkk.866 (.300) 0 60 9 79.96 (9) LC-DWKkk 3.60 (.650) LC-DPKkk Switching of multiple capacitor banks (with equal or different power ratings). The correct contactor for each step is selected from the above table, according to the power rating of the step to be switched. Example: 50 kvar 3-step capacitor bank. Temperature: F (50 C) and U = 00 V or 0 V. One 5 kvar step: contactor LC-DMK, one 5 kvar step: contactor LC-DGK and one 0 kvar step: contactor LC-DFK. c Standard control circuit voltages c Coil selection Volts 8 0 0 30 0 380 00 5 0 500 660 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 D6 E6 F6 M6 U6 Q6 R6 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 a The average temperature over a -hour period, in accordance with IEC 70 and 83 is 3 F (5 C). 0 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Contactors for capacitor switching Dimensions LC-DFK, DGK LC-DPK, DTK 30 7 80 7 c 5 50 75 LC- c Contactor LC- Contactor DFK 7 LC-D DPK LC-D0 DGK LC-D8 DTK LC-D50 LC-DLK, DMK LC-DWK 0 8 00 7 c 56 57 85 LC- c Contactor LC- Contactor DLK 7 LC-D5 DWK LC-D80 DMK LC-D3 Schemes LC-DkK () A A /T /L 3/L 5/L3 } R /T 6/T3 R R = Resistor connections, pre-wired () Mains supply () Application } () (3) } (3) Do not connect anything to these 3 auxiliary poles Cabling Contactor type LC- DFK DGK DLK DMK DPK, DTK DWK Number of conductors Stranded cable with cable end.5.5.5 6 6 6 50 5 Solid cable without cable end 6 6 0 6 6 0 5 6 50 35 7/98 998 Square D All Rights Reserved 03

D-Line Contactors, Overload Relays and Accessories Plate-mounted starters LC-D: International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Includes contactor and European style fused disconnect switch on mounting plate. LC-D09kk Utilization category AC-3 Fuses to be fitted by Catalog number. Weight the customer Complete with code Standard power ratings of 3-phase motors Operational indicating control 50/60 Hz current circuit voltage a c 0/30 V 380/00 V 5 V 0 V 500 V 660/690 V 0 up to Size Class am kw kw kw kw kw kw A A kg (lb.). 5.5 9 0 x 38 LC-D09kk 0.870 (.98) 3 5.5 5.5 5.5 7.5 0 x 38 6 LC-Dkk 0.870 (.98) 7.5 9 9 0 8 0 x 38 0 LC-D8kk.50 (.535) 5.5 5 5 0 x 38 5 LC-D5kk.580 (3.83) 7.5 5 5 5 8.5 8.5 3 x 5 3 LC-D3kk.630 (5.798) 8.5 30 0 x 5 0 LC-D0kk.930 (6.59) 5 5 30 30 33 50 x 58 63 LC-D50kk 3.00 (7.05) 8.5 30 37 37 37 37 65 x 58 80 LC-D65kk 3.30 (7.363) 37 5 5 55 5 80 x 58 80 LC-D80kk 3.650 (8.07) Specifications Pre-wired power and control circuit connections 3-pole off-load switch fuse: LC-D09 to D80 c Thermal overload relay to be ordered separately (see pages 76 and 77). a Coil selection Volts 8 0 0/30 30 0 380/00 00 5 0 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LC-D0kk 0 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Plate mounted starters - Dimensions and wiring diagrams LCD: International applications only Plate mounted starters LC-D09, D, D8, D5 9 00 xø. LC-D3 xø6. b 73 50 63 0 36 0 33 c c c () = = 55 7 86 = = 00 0 () 60 () (3) = 90 65 88 = LC- b c c c D09, D 8 0 3 D8 8 5 8 7 D5 0 36 55 c with LA-Dkkk () with LA-Dkkk c with LA-Dkk or LA3-Dkk () with LA-Dkk or LA3-Dkk () + mm with lead sealing kit (3) + mm with lead sealing kit LC-D0, D50, D65, D80 LC- a b b c c c c3 G xø7 D0 8 3 5 30 56 75 00 63 Plate mounted starters c c c () c3 b b = G = a xø7 = 60 = = 00/0 = D50, 8 3 5 30 56 75 78 63 D65 D80 3 3 8 0 63 8 78 93 c with LA-Dkkk c with LA-Dkk or LA3-Dkk () + mm with lead sealing kit Note: Dimensions are expressed in millimeters. To calculate inches, multiply by 0.039. For example, mm = (0.039) in. =.73 LC-D09 to D80 LC-D09 to D5 LC-D3 to D80 Q/ 0 9 Q/ Q F Q Q KM /L U 3/L 3 3 V 5/L3 W 6 5 6 5 6 Commande à distance N Q/6 3 KM 3 95 96 3 KM A A Commande à distance N Q/6 3 3 Q KM KM 3 96 95 A A 7/98 998 Square D All Rights Reserved 05

D-Line Contactors, Overload Relays and Accessories Wye-Delta starters LC3-D: International applications only Wiring methods differ from typical North American practice. Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Standard power ratings of squirrel cage motors Auxiliary contacts available on each contactor Star-delta mechanical interlock Catalog number. Complete with code indicating control circuit voltage a c Weight line KM delta KM3 star KM Mains voltage - delta connection 0 V 380 V 5 V 0 V kw kw kw kw kg (lb.) Plate mounted LC3-Dkk Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds. Without LC3-D09kk.500 (3.306) 7.5 7.5 7.5 q With LC3-D09kkA6.530 (3.373) Without LC3-Dkk.500 (3.306) 5.5 q With LC3-DkkA6.530 (3.373) Without LC3-D8kk.700 (3.78) 8.5 q With LC3-D8kkA6.730 (3.8) Without LC3-D3kk.000 (.09) 5 5 30 30 q With LC3-D3kkA6.030 (.75) Without LC3-D0kk.360 (9.6) 8.5 37 37 37 q With LC3-D0kkA6.500 (9.90) Without LC3-D50kk.360 (9.6) 30 55 59 59 q q With LC3-D50kkA6.500 (9.90) Without LC3-D80kk 5.00 (.6) 37 75 75 75 q q With LC3-D80kkA6 5.00 (.90) Rail mounted (35 mm DIN rail) Maximum operating rate: starts/hour. Maximum starting time: 30 seconds. 3 5.5 5.5 5.5 With LC3-K06kk.63 (0.70) 7.5 7.5 7.5 With LC3-K09kk.63 (0.70) Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds. 7.5 7.5 7.5 q 5.5 q 8.5 q 5 5 30 30 q Without LC3-D090kk.500 (3.306) With LC3-D090kkA6.530 (3.373) Without LC3-D0kk.500 (3.306) With LC3-D0kkA6.530 (3.373) Without LC3-D80kk.700 (3.78) With LC3-D80kkA6.730 (3.8) Without LC3-D30kk.000 (.09) With LC3-D30kkA6.030 (.75) c Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current. a Coil selection Star-delta starters LC3-K06 and K09 Volts AC 50/60 Hz 36 8 0 7 0/30 30 30/0 Code B7 C7 D7 E7 F7 FC7 M7 P7 U7 Star-delta starters LC3-D09 to D80, LC3-D090 to D30 Volts AC 50/60 Hz 8 0 0/ 30 30 0 380/00 00 5 0 Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 For other voltages, please consult your Regional Sales Office. q One auxiliary contact block type LA-Dkkk can also be added. 06 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Wye-Delta starting: International applications only Current.5.5 0.5 3 0 0 0.5 0.50 0.75 Speed Starting in direct delta connection Starting in star connection Torque 7 6 5 3 0 0 0.5 0.50 0.75 Starting in direct delta connection Starting in star connection 3 Machine resistive torque Speed This method of starting is only applicable to 3-phase motors whose delta connection corresponds to the mains voltage and on which all 6 stator terminals are accessible. Star-delta starting should be used for motors starting on no-load or having a low load torque and gradual build-up: - the starting torque in star connection is reduced to one third of the direct starting torque, i.e. about 50% of the rated torque; - the starting current in star connection is about.8 to.6 times the rated current. The transition from star to delta connection must occur when the machine has run up to speed. A too rapid build-up in load torque would cause the stabilised run-up speed to be too low and would therefore eliminate any advantage in this method of starting: this is the case with certain machines whose load torque depends on its speed (a characteristic of centrifugal machines, for example). All star-delta starters are supplied with a special LA-DS or LA-KTk time delay relay which imposes a delay on the delta contactor during the transition period in order to allow the star contactor sufficient breaking time. c Motor manufacturers generally specify machine load torques. Example: maximum resistive torque on completion of star-delta start (expressed as a proportion of the rated torque). 7/98 998 Square D All Rights Reserved 07

D-Line Contactors, Overload Relays and Accessories Wye-Delta starting: International applications only Wiring methods differ from typical North American practice d d c c KM a KM3 KM e c b 08 998 Square D All Rights Reserved 7/98

Wiring methods differ from typical North American practice Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Contactors Standard power ratings of squirrel cage motors f Mains voltage - delta connection D-Line Contactors, Overload Relays and Accessories Wye-Delta starter kits: International applications only Contactors (Catalog number. Complete with code indicating control circuit voltage) a c 0 V 380 V 5 V 0 V line delta star kw kw kw kw KM KM3 KM Type Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds. 7.5 7.5 7.5 LC-D090kk LC-D090kk LC-D090kk D09 5.5 LC-D0kk LC-D0kk LC-D090kk D 8.5 LC-D80kk LC-D80kk LC-D090kk D8 5 5 30 30 LC-D30kk LC-D30kk LC-D80kk D3 8.5 37 37 37 LC-D0kk LC-D0kk LC-D50kk D0 30 55 59 59 LC-D50kk LC-D50kk LC-D0kk D50 37 75 75 75 LC-D80kk LC-D80kk LC-D50kk D80 Component parts Description Illustration item no. (p.0) For use on Catalog number Component parts (see below) Assembly kit comprising: D09, D LA9-D7 0.80 (0.397) - instantaneous auxiliary contact block LA-DN (D09 to D0). a D8 LA9-D87 0.90 (0.9) - time delay contact block LA-DS (D09 to D80). b D3 LA9-D37 0.30 (0.683) - power circuit connections (D09 to D80). - screws and clamps for fixing contactors to mounting plate (D0 to D80). c d D0 LA9-D07 0.380 (0.838) - terminal block (D09 to D3). e D50 LA9-D507 0.80 (.058) D80 LA9-D807 0.680 (.99) Equipment mounting plate D09, D, D8 LA9-D97 0.50 (0.33) D3 LA9-D397 0.80 (0.397) D0 and D50 LA9-D0973 0.300 (0.66) D80 LA9-D80973 0.300 (0.66) c Protection must be provided by the addition of an overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 of the full load rated motor current, see pages 76 and 77. a See page 06. q For mounting, assembly and cabling: refer to installation instructions supplied with the equipment. Weight kg (lb.) 7/98 998 Square D All Rights Reserved 09

D-Line Contactors, Overload Relays and Accessories Wye-Delta starters Wiring diagrams LE3-D: International applications only Wye-delta starters with isolator LE3-D096 to D806 Q KM 3 5 KM3 6 3 5 KM Recommended cabling for reversal of motor rotation (standard motor viewed from shaft end). U V W 6 U V 3 5 W 6 6 3 5 6 U /L 3/L 5/L3 V W U V W 6 0 998 Square D All Rights Reserved 7/98

Wye-delta starters with isolator LE3-D096 to D6 LE3-D86 to D806 Q/ 0 9 Q/ Q 3 Q F 3 Q O 95 96 96 95 S 56 5 53 8 7 l KM KM 55 KM 67 3 3 KM l 56 53 (3) KM 5 () 68 KM 55 KM 67 3 KM 68 KM3 KM KM3 KM N KM A KM A KM3 A N KM A KM A KM3 A Q/6 A A A Q/6 A A A ( ) for LE3-D506, D806. 7/98 998 Square D All Rights Reserved

Enclosed IEC non-combination starters D-line in metal enclosures Horsepower ratings for North American applications E6336 CCN NKJH CCN NKJH7 LR05 06 3 08 D-line enclosed full voltage starters are available in Type and Type /3R enclosures through 50 hp at 60V. The enclosed D-line uses LC-D contactors and LR-D overload relays and accepts standard D-line accessories and all Insta-kit pilot device and control power transformer kits. Enclosed full voltage non-reversing startersa Max. Horsepower Ratings (AC3) Auxiliary Contacts Catalog Number c a Weight Catalog Number c a Weight Phase 3 Phase 5 30 00V 30V 60V 575V N.O. N.C. Type lb. Type/3R lb. 0.5 5 7.5 - LE--UD0936kk 6.90 LE-UD0937kk 7.70 3 3 7.5 0 - LE-UD36kk 6.90 LE-UD37kk 7.70 3 5 5 0 5 - LE-UD836kk 6.93 LE-UD837kk 7.73.5 3 5 7.5 5 0 - LE-UD536kk 7.8 LE-UD537kk 8.08 5 7.5 0 0 5 - LE-UD336kk 9.58 LE-UD337kk 0. 3 5 0 0 30 30 LE-UD036kk. LE-UD037kk.7 3 7.5 0 5 30 0 LE-UD5036kk. LE-UD5037kk.7 5 0 5 0 0 50 LE-UD6536kk 6.8 LE-UD6537kk 7. 5 0 0 0 50 60 LE-UD8036kk 6.83 LE-UD8037kk 7.79 c Substitue S in place of in catalog number for single phase devices. Ex: LES-UD0936k Enclosed full voltage reversing startersa Max. Horsepower Ratings (AC3): 3 Phase Auxiliary Contacts Catalog Number Weight Catalog Number Weight 00V 30V 60V 575V N.O. N.C. Type lb. Type/3R lb. 5 7.5 LE-UD0936kk 9.93 LE-UD0937kk 0.8 3 3 7.5 0 LE-UD36kk 9.96 LE-UD37kk 0.8 5 5 0 5 LE-UD836kk 0.08 LE-UD837kk 0.9 5 7.5 5 0 LE-UD536kk - LE-UD537kk - 7.5 0 0 5 LE-UD336kk - LE-UD337kk - 0 0 30 30 LE-UD036kk - LE-UD037kk - 0 5 30 0 LE-UD5036kk - LE-UD5037kk - 5 0 0 50 LE-UD6536kk - LE-UD6537kk - 0 0 50 60 LE-UD8036kk - LE-UD8037kk - Coil voltages for enclosed non-combination starters a Coil selection Volts 0 0 7 08 0 0 77 380 5 0 80 575 600 50Hz B5 F5 - G5 - M5 U5 - Q5 N5 R5 - - - 60Hz B5 F6 G6 - L6 M6 U6 W6 Q6 - R6 T6 S6 X6 50/60Hz B7 F7 - - - M7 U7 - Q7 N7 R7 - - - a Bimetallic overload relay must be ordered separately. See Page 07 for thermal overload relay tables. See Pages to 9 for a complete selection of D-line accessories. See Page 6 for Insta-Kit accessories. How to order: To order specify - Type number - Coil voltage code - Insta-Kits - Overload relays Catalog number Type Coil code Insta-kits form Overload relay (separate item) LE-UD0936 F7 AP LR-D305 998 Square D All Rights Reserved 7/98

Enclosed IEC non-combination starters Overload relays for non-combination starters LE-UD non-combination starter Motor full load current range Amperes For direct mounting under Contactor LE/LE Class 0 Catalog number Class 0 Catalog number.0-.6 DO9-D3 LRD30 -.06-.5 DO9-D3 LRD30 -.5-.0 DO9-D3 LRD303 -.0-.63 DO9-D3 LRD30 -.63- DO9-D3 LRD305 - -.6 DO9-D3 LRD306 -.6-.5 DO9-D3 LRD307 -.5- DO9-D3 LRD308 LRD508-6 DO9-D3 LRD30 LRD50 5.5-8 DO9-D3 LRD3 LRD5 7-0 DO9-D3 LRD3 LRD5 9- D-D3 LRD36 LRD56-7.5 D-D3 LRD3 LRD5 7- D5 LRD3 LRD5 7-5 D3 LRD3 LRD5 3-8 D3 LRD353 LRD553 3-30 D0-80 LRD3353 LRD3553 30-37 D0-80 LRD3355 LRD3555 37-0 D0 LRD3357 LRD3557 37-8 D50-80 LRD3357 LRD3557 8-56 D65-80 LRD3359 LRD3559 55-63 D80 LRD336 LRD356 63-65 D80 LRD3363 LRD3563 7/98 998 Square D All Rights Reserved 3

Enclosed IEC combination starters D-Line in metal enclosure with fusible disconnect switch or circuit breaker Horsepower ratings for North American applications E6336 NKJH NKJH7 LR0506 3 08 IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient compact package. All devices provide Type Coordination through 30 hp at 60V. Devices are available in Type and Type /3R enclosures. The IEC combination starter line accepts standard D-line accessories and all Insta-kit pilot device and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. Enclosed full voltage non-reversing fusible combination startersa Max. Horse Power Ratings (AC3) Fuse Clip Rating Auxiliary Catalog Number c Weight Catalog Number c Weight 3 Phase Contacts 00V 30V 60V 575V Amperes UL Class N.O. N.C. TYPE lb. Type /3R lb. 5 7.5 30A CC - LE-UD0986kk 8 LE-UD0987kk 8 3 3 7.5 0 30A CC - LE-UD86kk 8 LE-UD87kk 8 5 5 0 5 30A J - LE-UD886kk 8 LE-UD887kk 8 5 7.5 5 0 30A J - LE-UD586kk 8 LE-UD587kk 8 7.5 0 0 5 60A J - LE-UD386kk 6 LE-UD387kk 6 0 0 30 30 60A J LE-UD086kk 8 LE-UD087kk 8 Enclosed full voltage reversing fusible combination startersa Max. Horse Power Ratings (AC3) Fuse Clip Rating Auxiliary Catalog Number c Weight Catalog Number c Weight 3 Phase Contacts 00V 30V 60V 575V Amperes UL Class N.O. N.C. TYPE lb. Type /3R lb. 5 7.5 30A CC LE-UD0986kk 6 LE-UD0987kk 6 3 3 7.5 0 30A CC LE-UD86kk 6 LE-UD87kk 6 5 5 0 5 30A J LE-UD886kk 6 LE-UD887kk 6 5 7.5 5 0 30A J LE-UD586kk 6 LE-UD587kk 6 7.5 0 0 5 60A J LE-UD386kk 7 LE-UD387kk 7 0 0 30 30 60A J LE-UD086kk 3 LE-UD087kk 3 Enclosed full voltage non-reversing circuit breaker combination startersa Max. Horse Power Ratings (AC3) Auxiliary Contacts Maximum Catalog Number c Weight Catalog Number c Weight 3 Phase Current Rating Circuit Breaking 00V 30V 60V 575V N.O. N.C. TYPE lb. Type /3R lb. 5 7.5-5A LE-UD0996kk 0 LE-UD0997kk 0 3 3 7.5 0-5A LE-UD96kk 0 LE-UD97kk 0 5 5 0 5-30A LE-UD896kk 0 LE-UD897kk 0 5 7.5 5 0-30A LE-UD596kk 0 LE-UD597kk 0 7.5 0 0 5-50A LE-UD396kk 7 LE-UD397kk 7 0 0 30 30 50A LE-UD096kk 9 LE-UD097kk 9 Enclosed full voltage reversing circuit breaker combination startersa Max. Horse Power Ratings (AC3) Auxiliary Contacts Maximum Catalog Number c Weight Catalog Number c Weight 3 Phase Current Rating Circuit Breaking 00V 30V 60V 575V N.O. N.C. TYPE lb. Type /3R lb. 5 7.5 5A LE-UD0996kk LE-UD0997kk 3 3 7.5 0 5A LE-UD96kk LE-UD97kk 5 5 0 5 30A LE-UD896kk 8 LE-UD897kk 8 5 7.5 5 0 30A LE-UD596kk 8 LE-UD597kk 8 7.5 0 0 5 50A LE-UD396kk 8 LE-UD397kk 8 0 0 30 30 50A LE-UD096kk 3 LE-UD097kk 3 acoil selection Volts 0 0 7 08 0 0 77 380 5 0 80 575 600 50Hz B5 F5 G5 M5 U5 Q5 N5 R5 60Hz B6 F6 G6 L6 M6 U6 W6 Q6 R6 T6 S6 X6 50/60Hz B7 F7 M7 U7 Q7 N7 R7 How to order: To order specify - Type number - Coil voltage code - Insta-Kits - Overload relays Catalog number Type Coil Code Insta-kits form Overload relay (separate item) LE-UD0986 F7 AP LR-D305 c Thermal overload relay must be ordered separately. See page 5 for selection. a Bimetallic overload relay must be ordered separately. See page 5 for selection. See pages to 9 for a complete selection of D-Line accessories. See page 6 for Insta-Kit accessories. 998 Square D All Rights Reserved 7/98

Enclosed IEC combination starters Overload relays for combination starters with fusible disconnect switch or circuit breaker LE-UD enclosed combination starters Current Setting Range For Direct Mounting under Contactor LC/LC Amperes Fusible Circuit Breaker Class 0 Catalog Number Class 0 Catalog Number.0 -.6 D09-D5 LR-D30.6 -.5 D09-D5 LR-D30.5 -.0 D09-D5 LR-D303.0 -.63 D09-D5 LR-D30.63 - D09-D5 LR-D305 -.6 D09-D5 LR-D306.5 - D09-D5 LR-D306.6 -.5 D09-D5 LR-D307.5 - D09-D5 LR-D308 LR-D508-6 D09-D5 D09-D LR-D30 LR-D50 5.5-8 D09-D5 D09-D LR-D3 LR-D5 7-9 D09-D5 D09-D LR-D3 LR-D5 9 - D-D5 D LR-D36 LR-D56-7.5 D8-D5 D8-D5 LR-D3 LR-D5 7 - D5 D5 LR-D3 LR-D5 7-5 D3 D3 LR-D3 LR-D5 3-8 D3 D3 LR-D353 LR-D553 3-30 D0 D0 LR-D3353 LR-D3553 30-37 D0 D0 LR-D3355 LR-D3555 37-0 D0 D0 LR-D3357 LR-D3557 7/98 998 Square D All Rights Reserved 5

Enclosed IEC combination starters Insta-Kits Insta-Kits prewired prewired pilot device kits and control power transformer kits can be factory installed by selecting the factory modification form number or installed by the customer by selecting the Insta-Kits reference number as a separate item. LA9FFTK Insta-Kits Selection E639 CCN XPTQ CCN XPTQ7 All others E839 CCN NKCR CCN NKCR7 a Replace (*) with the suffix letter corresponding to the pilot light voltage. Voltage V 0V 08/0V 80V Suffix Letter B K P W LR05 06 3 0 Description Factory Modification Insta-Kit Form Catalog Number On/Off Selector Switch C6 LA9-C6 Hand-Off-Auto Selector Switch C LA9-C Green Pilot Light (0V) P c LA9-P c Red Pilot Light (0V) P c LA9-P c Green Transformer Pilot Light P5 c LA9-P55* ac Red Transformer Pilot Light P5 c LA9-P55* ac Start/Stop Pushbutton A LA9-A Start/Stop (Mushroom Head) Pushbutton A LA9-A I/O (Start/Stop) Pushbutton A6 On/Off Selector Switch with Green Pilot Light (0V) C6P LA9-C6P On/Off Selector Switch with Red Pilot Light (0V) C6P LA9-C6P Hand-Off-Auto Selector Switch with Green Pilot Light CP LA9-CP Hand-Off-Auto Selector Switch with Red Pilot Light CP LA9-CP H-O-A Selector Switch with Green Transformer Pilot Light CP5 LA9-CP55* a H-O-A Selector Switch with Red Transformer Pilot Light CP5 LA9-CP55* a Forward-Reverse-Stop Pushbuttons A LA9-A Start/Stop Pushbutton with Green Pilot Light (0V) AP LA9-AP Start/Stop Pushbutton with Red Pilot Light (0V) AP LA9-AP Start/Stop Pushbutton with Green Transformer Pilot Light AP5 LA9-AP55* a Start/Stop Pushbutton with Red Transformer Pilot Light AP5 LA9-AP55* a Standard Control Transformer with Top Mounted Fuse Block: 50 VA Transformer 80/0V-0V FFT LA9-FFTKF50D 50 VA Transformer 08-0V FFT LA9-FFTKF50D3 00 VA Transformer 80/0V-0V FFT0 LA9-FFTKF00D 00 VA Transformer 08-0V FFT0 LA9-FFTKF00D3 50 VA Transformer 80/0V-0V FFT LA9-FFTKF50D 50 VA Transformer 08-0V FFT LA9-FFTKF50D3 Local/Remote Adapter - Three Wire c LA9-3W Local/Remote Adapter - Four Wire c LA9-W Local/Remote Adapter - Five Wire c LA9-5W Local/Remote Adapter - Seven Wire c LA9-7W Kit for Remote LA9-FK For factory modification, add form number to the end of the catalog number. k LA93W required when START/STOP pushbutton remote station is used in conjunction with START/STOP local control OR if local pilot light only is used. k LA9W required when FOR/REV/STOP is required for both local and remote control. k LA95W required when START/STOP pushbutton with pilot light remote station OR pilot light oly remote is used with START/STOP pushbutton local control. k LA97W required for remote control only applications. Insta-Kits shown with LE-UD non-combination starter Insta-Kits is a trademark of Schneider Canada. 6 998 Square D All Rights Reserved 7/98

Approximate dimensions Enclosed combination and non-combination IEC starters Combination starter dimensions Type Dimensions in inches 0" 5" /" 7 /" 8" 3" /" 7 /" / " " 6 / " 8 " Provision for /" screw D09-D5 FVNR Provision for /" screw D09-D5 FVR D3-D0 FVNR and FVR Type /3R 0" 5" /" 3/8" 7 3/" 8" 3" /" 3/8" 7 3/" 5 5/8" 7/8" " 9 5/8 " 8 7/8 " 8 " 7/6" Provision for /" screw 7/6" Provision for /" screw D09-D5 FVNR D09-D5 FVR D3-D0 FVNR and FVR Non-combination starter dimensions A.50 Dimensions shown in inches J K R C B E.75.56 D D/ PROVISION FOR /" SCREW F G H TYPE TYPE /3R Non-reversing Reversing A B C D E F G H J K D E D09-5 6.77 0.0 6.5 5.38 9.00 - / / - 3 / - / / - 3 / 5.38.37 D3-50 D09-3 8.66 0.83 7. 7.5 9.75 / - / / - 3 / - / - / / - 3 / 5.38.5 D65-80 D0-80 0.63 3.98 7. 9..9 / - / / - 3 / - / - / / - 3 / 5.38 5.30 Type enclosures include conduit knockouts indicated by F, G, H, J and K diameter dimensions. Type /3R enclosures do not include conduit knockouts. For additional information on combination starters, reference catalog number 950HO960. For additional information on non-combination starters, reference catalog number 950HO90. 7/98 998 Square D All Rights Reserved 7

Schemes Enclosed IEC non-combination starters Non-reversing, non-combination 3-phase starter LE-UDkk36 and LE-UDkk37 GND A A L L L3 3 7 8 9 M 5 6 A3 T T T3 3 97 95 D0 Only Insta-Kit Harness Receptacle ALARM OL 98 T T T3 96 Non-reversing, non-combination -phase starter LES-UDkk36 and LES-UDkk37 GND A A L L L3 3 7 8 9 M 5 6 A3 T T T3 3 97 95 D0 Only Insta-Kit Harness Receptacle ALARM OL 98 T T T3 96 Reversing, non-combination 3-phase starter LE-UDkk36 and LE-UDkk37 Insta-Kit Harness Receptacle GND A A FWD L L L3 O 3 A A REV L L L3 O 3 7 8 9 F F 5 6 A3 FWD T T T3 O FWD A3 REV T T T3 O REV 3 97 95 ALARM OL 98 T T T3 96 8 998 Square D All Rights Reserved 7/98

Schemes Enclosed IEC combination starters Non-reversing, combination 3-phase starter LE-UDkk86 and LE-UDkk87, 97 L L L3 Disconnecting Means T T T3 GND 7 8 9 A A FWD L L L3 3 5 6 F 3 A3 FWD T T T3 Insta-Kit Harness Receptacle Alarm 97 95 OL D0 Only 98 T T T3 96 Reversing, combination 3-phase starter LE-UDkk86, 96 and LE-UDkk87, 97 L L L3 Disconnecting Means T T T3 A A REV L L L3 O 3 A A FWD L L L3 O 3 R F REV A3 T T T3 O A3 FWD T T T3 O GND 37 33 7 8 9 5 6 38 T T T3 6 OL 3 Insta-Kit Harness Receptacle 7/98 998 Square D All Rights Reserved 9

Enclosed contactors LE-D International applications only Contains UL listed, CSA certified and CE marked components. Assemblies are not UL listed or CSA certified. LE-D093kk LE-D05kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 c Overload protection by thermal overload relay, to be ordered separately. Operational current 0 V up to Type of enclosure Basic reference. Complete with code indicating control circuit voltage a 0/30 V 380/00 V 5 V 0 V 500 V 660/690 V kg (lb) kw kw kw kw kw kw A.5.. 3 6 LE-K06kk 0.55 (.) Protected LE-K06kkA3 0.9 (.08). f 9 Sealed Protected Weight LE-K065kk 0.55 (.) LE-K065kkA3 0.9 (.08) LE-K09kk 0.55 (.) LE-K09kkA3 0.9 (.08) LE-K095kk 0.55 (.) Sealed LE-K095kkA3 0.9 (.08). f 5.5 5.5 9 Protected LE-D09kk 0.55 (.) Sealed LE-D093kk 0.9 (.08) 3 5.5 5.5 5.5 7.5 7.5 Protected LE-Dkk 0.55 (.) Sealed LE-D3kk 0.9 (.08) 7.5 9 9 0 0 8 Protected LE-D88kk 0.995 (.93) Sealed LE-D85kk.05 (.38) 5.5 5 5 5 Protected LE-D58kk 0.995 (.93) Sealed LE-D55kk.05 (.38) 7.5 5 5 5 8.5 8.5 3 Sealed LE-D35kk.3 (9.5) 8.5 30 0 Sealed LE-D05kk.8 (0.66) 5 5 30 30 33 50 Sealed LE-D505kk.85 (0.69) 8.5 30 37 37 37 37 65 Sealed LE-D655kk.85 (0.69) 37 5 5 55 5 80 Sealed LE-D805kk 5. (.33) 5 5 5 5 55 5 95 Sealed LE-D955kk 5. (.993) Specifications Enclosure Control by pushbuttons mounted on enclosure cover LE-K06 and K09 Double insulated enclosure, IP 659, l: 80 mm Double insulated enclosure, IP 659, l: LE-K06kkkA3, LE-K09kkkA3 75 mm LE-D09 and D Double insulated enclosure, IP 659 LE-D8 and D5 Double insulated enclosure, IP 557 LE-D3 to D95 Metal enclosure, IP 559 LE-K06 and K09, LE-D09 to D95 green Start button I red Stop/Reset button O Connections LE-D09 to D95 Pre-wired power circuit connections a Coil selection LE-K Volts AC 50/60 Hz 36 8 0 7 0/30 30 30/0 380/00 00 00/5 0 500 660/690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE-D Volts AC 50/60 Hz 8 0 0/30 30 0 380/00 00 5 0 Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: LE-K and LE-D please consult your Regional Sales Office. 0 998 Square D All Rights Reserved 7/98

Enclosed contactors LE-D Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference a No pushbuttons on cover LE-D09 to D95 A0 blue Reset button R LE-D09 to D95 A05 3-position selector switch ( I - O - II ) ( I : Automatic Start; O : Stop; II : Manual start) blue Reset button R -position selector switch O - I ( O : Stop; I : Manual Start) blue Reset button "R Knock-outs for x 6P cable glands (instead of x 3P) green Start button I red Stop button O blue Reset button R Special device for control of compressor and vacuum valve (no-load starting). Maintained control. Limits the IP rating to only. neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply. LE-D09 and D LE-D09 and D LE-D09 and D LE-D09 and D LE-D09 to D5 LE-K06 and K09 LE-D09 to D95 A09 A3 A0 A35 A0 A59 Accessories (mounted by the customer) Description For use on Reference Start button latching device for stay-put operation (Start-Stop) Miniature control circuit fuse holder size 5 x 0 A/50 V Fuse supplied a Example: LE-D093F7A0. Weight kg (lb.) LE-D8 to D65 LA9-D09907 0.060 (0.3) LE-D09 and D LA9-D93 0.00 (0.088) LE-D8 and D5 LA9-D9 0.05 (0.055) 0 V LE-D09 to D5 LA9-D9 0.00 (0.0) Pilot light with neon bulb red lens and locking ring 0 V LE-D09 to D5 LA9-D95 0.00 (0.0) 380, 5 V LE-D09 to D5 LA9-D96 0.00 (0.0) front-mounting block of auxiliary contacts LE-D09 to D95 LA-DNii 0.030 (0.066) 7/98 998 Square D All Rights Reserved

Enclosed contactors with fused disconnect switch LE-K and LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-K065kk LE-D096kk Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Operational current Fuses to be fitted by the customer Basic reference. Complete with code indicating control circuit voltage a 0/30 V 380/00 V 5 V 0 V 500 V 660/690 V 0 V up to Size Type am kw kw kw kw kw kw A A lb (kg).5.. 3 6 0 x 38 0 LE-K065kk.50 (3.97) LE-K095kk.50 (3.97). 9 0 x 38 LE-D096kk q.960 (.3). 5.5 9 0 x 38 LE-D096kk.960 (.3) 3 5.5 5.5 5.5 7.5 0 x 38 6 LE-D6kk.960 (.3) 7.5 9 9 0 8 0 x 38 0 LE-D86kk.00 (.850) 5.5 5 5 0 x 38 5 LE-D56kk.00 (.850) 7.5 5 5 5 8.5 8.5 3 x 5 3 LE-D36kk 5.90 (.) 8.5 30 0 x 5 0 LE-D06kk 5.770 (.70) 5 5 30 30 33 50 x 58 63 LE-D506kk 6.0 (.98) 8.5 30 37 37 37 37 65 x 58 80 LE-D656kk 6.670 (.705) 37 5 5 55 5 80 x 58 80 LE-D806kk f 7.00 (5.653) Specifications Enclosure Control by pushbuttons mounted on enclosure cover LE-K06, K09 Double insulated enclosure, IP 659 LE-D09 to D5 Double insulated enclosure, IP 557 LE-D3 to D80 Metal enclosure, IP 559 LE-K06, K09 LE-D09 to D65 No pushbuttons on cover LE-D80 Isolator with external operator Connections LE-K06, K09 LE-D09 to D5 LE-D3 to D80 LE-K06, K09 LE-D09 to D80 green Start button I red Stop/Reset button O 3-pole isolator 3-pole isolator + additional pole LA8-D5 3-pole isolator and circuit breaker GB-CB08 Pre-wired power and control circuit connections. Weight c Overload protection by thermal overload relay to be ordered separately. a Coil selection LE-K Volts AC 50/60 Hz 36 8 0 7 0/30 30 30/0 380/00 00 00/5 0 500 660/690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE-D Volts AC 50/60 Hz 8 0 0/30 30 0 380/00 00 5 0 Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: LE-K and LE-D, please consult your Regional Sales Office. q Selected according to overall dimensions and number of operating cycles. f Supplied with 3 entries. LE-D06kk 998 Square D All Rights Reserved 7/98

Enclosed contactors with fused disconnect switch LE-K and LE-D International applications only Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference a No pushbuttons on cover LE-D09 to D65 A0 blue Reset button R LE-D09 to D80 A05 Special device for control of compressor and vacuum valve (no-load starting). Maintained control. Limits IP rating to only. neutral terminal. Fitted as standard on starters ordered with 0 V (U7) control supply. Accessories (mounted by the customer) LE-D09 to D5 LE-K06 and K09 LE-D09 to D80 A0 A59 Description For use on Catalog number Weight kg (lb.) Start button latching device for stay-put operation (Start-Stop) Miniature control circuit fuse holder size 5 x 0, A/50 V Fuse supplied LE-D09 to D65 LA9-D09907 0.060 (0.35) LE-D09 to D5 LA9-D9 0.05 (0.056) Pilot light with neon bulb red lens and locking ring front-mounting block of auxiliary contacts 0 V LE-D09 to D5 LA9-D9 0.00 (0.05) 0 V LE-D09 to D5 LA9-D95 0.00 (0.05) 380, 5 V LE-D09 to D5 LA9-D96 0.00 (0.05) LE-D09 to D95 LA-DNkk 0.030 (0.067) a Example: LE-D096F7A0. 7/98 998 Square D All Rights Reserved 3

Enclosed starters LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified LE-D3 Operational current up to Minimum c.s.a. of phase conductors Fuses to be fitted separately For use with relay LR-D or kit LA9-D (to be ordered separately) Basic reference. Complete with code indicating control circuit voltage a am gi A mm A A kg (lb.) 6.5 6 LA9-D75 f LE-D3kk 0.90 (.06) 7.5.5 0 LR-D3 q LE-D3kk 0.90 (.06).5 5 LR-D3 q LE-D55kk.05 (.78) 3 6 3 LA9-D0975 f LE-D55kk.05 (.78) 50 0 50 LE-D05kkA0 t.80 (0.86 57 0 63 LR-D3359 q LE-D05kk.80 (0.86) 63 6 63 LE-D655kkA0 t.850 (0.883) 76 6 80 LR-D3363 q LE-D655kk.850 (0.883 90 5 00 LR-D3365 q LE-D805kk 5.0 (.53) 00 35 00 LE-D805kkA0 t 5.0 (.53) Specifications Enclosure LE-D Double insulated, degree of protection IP 659 LE-D5 Double insulated, degree of protection IP 557 LE-D0 to D80 Metal, degree of protection IP 559 Control ( pushbuttons mounted on enclosure cover) No pushbuttons on cover LE-D to D80 green Start button I red Stop/Reset button O Weight LE-DkkkkkA0 Connections LE-D to D80 Pre-wired control circuit connections c 3-phase 0/30 V or 380/00 V or 5 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 95 F ( 35 C), conforming to NF C 5-00. a Control circuit voltage 0/30 V 50/60 Hz (code M7) or 380/00 V (code Q7). q Order the required LR-D thermal overload relay separately. For use on balanced circuits only. f As protection is provided by type gi fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA9-Dkk75. t Equipment supplied without pushbuttons; external Start-Stop station required. LE-D05 998 Square D All Rights Reserved 7/98

Enclosed starters LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. Forms (mounted by Telemecanique) Description For use on Suffix to be added to the reference q No pushbuttons on cover LE-D & D5 A0 blue Reset button R LE-D to D80 A05 green Start button I and red Stop button "O with N.C. contact (for distribution circuits without thermal overload relay) -position selector switch "O-I ("O : Stop ; "I : Manual Start) blue Reset button "R Knock-outs for x 6 mm plastic cable glands (instead of x 3 plastic glands) LE-D & D5 LE-D LE-D A07 A3 A0 neutral terminal (3-phase + N circuits) LE-D to D80 A59 Accessories (mounted by the customer) Description For use on Unit reference Weight kg (lb.) Start button latching device for stay put operation (Start-Stop) LE-D5 to D65 LA9-D09907 0.060 (0.3) Kits to provide stop function without thermal overload relay fitted Miniature control circuit fuse holder size 5 x 0 A /50 V Fuse supplied Pilot light with neon bulb, red lens and locking ring front-mounting block of auxiliary contacts (see page????) LE-D LA9-D75 0.00 (0.088) LE-D5 LA9-D0975 0.00 (0.0) LE-D LA9-D93 0.00 (0.088) LE-D5 LA9-D9 0.05 (0.055) 0 V LE-D & D5 LA9-D9 0.00 (0.0) 0 V LE-D & D5 LA9-D95 0.00 (0.0) 380, 5 V LE-D & D5 LA9-D96 0.00 (0.0) LE-D to D80 LA-DNkk 0.030 (0.066) c 3-phase 0/30 V or 380/00 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 95 F (35 C), conforming to NF C 5-00. a Order LR-D thermal overload relay separately. For use on balanced circuits only. q Example: LE-D3M7A0. 7/98 998 Square D All Rights Reserved 5

Enclosed starters with fused disconnect switch LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-D6kk Operational Minimum c.s.a. Fuses to be fitted by customer For use with relay LR- Basic reference. Weight current up to of phase D or kit LA9-D (to be Complete with code conductors Size Type ordered separately) indicating control circuit am gi voltage a A mm A A kg (lb.) 6.5 0 x 38 6 LA9-D0975 f LE-D6kk.960 (.3) 7.5.5 0 x 38 0 LR-D3 q LE-D6kk.960 (.3) 0.5 0 x 38 0 LA9-D0975 f LE-D56kk.00 (.850).5 0 x 38 5 LR-D3 q LE-D56kk.00 (.850) 0 0 x 5 0 LE-D06kkA0 t 5.770 (.70) 5 0 x 5 50 LR-D3357 q LE-D06kk 5.770 (.70) 63 6 x 58 63 LE-D656kkA0 t 6.670 (.70) 76 6 x 58 80 LR-D3363 q LE-D656kk 6.670 (.70) 90 5 x 58 00 LR-D3365 q LE-D806kk t 7.00 (5.65) 00 35 x 58 00 LE-D806kk t 7.00 (5.65) Specifications Enclosure Control ( pushbuttons mounted on enclosure cover) No pushbuttons on cover LE-D and D5 Double insulated, degree of protection IP 557 LE-D0 to D80 Metal, degree of protection IP 559 LE-D to D65 LE-DkkkkkA0 LE-D80 green Start button I red Stop/Reset button O Isolator with LE-D and D5 3-pole isolator + additional pole LA8-D5 external operator LE-D0 to D80 3-pole isolator + circuit breaker GB-CB08 Connections LE-D to D80 Pre-wired power and control circuit connections c 3-phase 0/30 V or 380/00 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, ceilings, in cable racks or ducting, laid singly, ambient temperature 95 F (35 C), conforming to NF C 5-00. a Control circuit voltage 0/30 V 50/60 Hz (code M7) or 380/00 V (code Q7). q Order the required LR-D thermal overload relay separately. For use on balanced circuits only. f As protection is provided by type gi fuses only, the Stop function normally provided by the thermal overload relay (where am type fuses are used) can be obtained by means of kit LA9-D0975. t Equipment supplied without pushbuttons; external Start-Stop station required. LE-D06 6 998 Square D All Rights Reserved 7/98

Enclosed starters with fused disconnect switch LE-D International applications only Forms (mounted by Telemecanique) Description For use on Suffix to be added to reference q No pushbuttons on cover LE-D & D5 A0 blue Reset button R LE-D to D80 A05 green Start button I and red Stop button O with N.C. contact (for distribution circuits without thermal overload relay) LE-D & D5 A07 neutral terminal (for 3-phase + N circuits) LE-D to D80 A59 Accessories (mounted by the customer) Description Start button latching device for stay put operation (Start-Stop) Kit to provide Stop function without thermal overload relay fitted Miniature control circuit fuse holder size 5 x 0, A/50 V Fuse supplied Pilot light with neon bulb, red lens and locking ring front-mounting block of auxiliary contacts (see page????) For use on Reference Weight kg (lb.) LE-D to D65 LA9-D09907 0.060 (0.3) LE-D & D5 LA9-D0975 0.00 (0.0) LE-D & D5 LA9-D9 0.05 (0.055) 0 V LE-D & D5 LA9-D9 0.00 (0.0) 0 V LE-D & D5 LA9-D95 0.00 (0.0) 380, 5 V LE-D & D5 LA9-D96 0.00 (0.0) LE-D to D80 LA-DNkk 0.030 (0.066) c 3-phase 0/30 V or 380/00 V 50/60 Hz. 3-core or 3 + N (unprotected neutral) insulated PVC cable, fixed to walls, in cable racks or ducting, laid singly, ambient temperature 95 F (35 C), conforming to NF C 5-00. a Order the required LR-D thermal overload relay separately. For use on balanced circuits only q Example: LE-D6M7A0. 7/98 998 Square D All Rights Reserved 7

Enclosed reversing starters LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-K065 Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V Operational current 0 V up to Basic reference. Complete with code indicating control circuit voltage a kw kw kw kw kw kw A kg (lb.).5.. 3 6 LE-K065kk.080 (.38). 9 LE-K095kk.080 (.38) or LE-D095kk q.00 (.630) 5.5 5.5 9 LE-D095kk.00 (.630) 3 5.5 5.5 5.5 7.5 7.5 LE-D5kk.00 (.630) 7.5 9 9 0 0 8 LE-D85kk.0 (5.33) 5.5 5 5 5 LE-D55kk.570 (5.666) 7.5 5 5 5 8.5 8.5 3 LE-D35kk.00 (9.039) 8.5 30 0 LE-D05kk 5.70 (.68) 5 5 30 30 33 50 LE-D505kk 5.70 (.059) 8.5 30 37 37 37 37 65 LE-D655kk 5.70 (.059) 37 5 5 55 5 80 LE-D805kk 6.700 (.77) 5 5 5 5 55 5 95 LE-D955kk 7.000 (5.3) Specifications Enclosure LE-K065 and K095 Double insulated enclosure, IP 659 LE-D09 to D5 Double insulated enclosure, IP 557 LE-D3 to D95 Metal enclosure, IP 559 Control by operator mounted on enclosure cover LE-D09 to D95 blue Reset button R Connections LE-D09 to D95 Pre-wired power and control circuit connections Weight Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference t No pushbuttons on cover LE-D09 to D95 A0 blue Reset button R LE-K06 and K09 A05 LE-D095 green Start button I green Start button II red Stop/Reset button O LE-D09 to D95 A neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply LE-K06 and K09 LE-D09 to D95 A59 c Overload protection by thermal overload relay, to be ordered separately. a Coil selection LE8-K Volts AC 50/60 Hz 36 8 0 7 0/30 30 30/0 380/00 00 00/5 0 500 660/690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE-D Volts AC 50/60 Hz 8 0 0/30 30 0 380/00 00 5 0 Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 LE-D05 8 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Enclosed reversing starters with fused disconnect switch LE-D International applications only Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE-D096 Standard power ratings of 3-phase motors 50/60Hz in category AC-3 0 V 30 V 380 V 00 V 5 V 0 V 500 V 660 V 690 V Operational current 0 V up to Fuses to be fitted by the customer Size Type am Basic reference. Complete with code indicating control circuit voltage a kw kw kw kw kw kw A A kg (lb.).5.. 3 6 0 x 38 0 LE8-K065kk.60 (3.57) LE8-K095kk.60 (3.57). 9 0 x 38 or LE-D096kkq 3.55 (7.86) 5.5 9 0 x 38 LE-D096kk 3.55 (7.86) 3 5.5 5.5 5.5 7.5 0 x 38 6 LE-D6kk 3.55 (7.86) 7.5 9 9 0 8 0 x 38 0 LE-D86kk 3.70 (8.57) 5.5 5 5 0 x 38 5 LE-D56kk.67 (0.95) 7.5 5 5 5 8.5 8.5 3 x 5 3 LE-D36kk 5.80 (.787) 8.5 30 0 x 5 0 LE-D06kk.7 (3.) 5 5 30 30 33 50 x 58 63 LE-D506kk.70 (3.) 8.5 30 37 37 37 37 65 x 58 80 LE-D656kk.77 (3.56) 37 5 5 55 5 80 x 58 80 LE-D806kk 6.00 (35.7) Specifications LE8-K065 and K095 Double insulated enclosure, IP 659 Enclosure LE-D09 to D80 Metal enclosure, IP 559 Control by operator mounted on enclosure cover LE-D09 to D5 blue Reset button R No pushbuttons on cover LE-D3 to D80 Isolator with external operator Connections LE-D09 to D5 LE-D3 to D80 LE8-K06, K09 LE-D09 to D80 Weight 3-pole isolator + additional pole LA8-D5 3-pole isolator and circuit breaker GB-CB08 Pre-wired power and control circuit connections Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference f No pushbuttons on cover LE-D09 to D5 A0 blue Reset button R green Start button I green Start button II red Stop/Reset button O neutral terminal. Fitted as standard on starters ordered with 0 V (U7) control supply. LE8-K06 and K09. LE-D3 to D80 LE-D09 to D80 LE8-K06, K09 LE-D09 to D80 A05 A A59 c Overload protection by thermal overload relay, to be ordered separately. a Standard control circuit voltages, see page 30. f Example: LE-D096F7A0. LE-D06 7/98 998 Square D All Rights Reserved 9

D-Line Contactors, Overload Relays and Accessories Wye-Delta starters LE3-D International applications only Wiring methods differ from typical North American practice. Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE3-D095 Standard power ratings of squirrel cage motors q Mains voltages - delta connection 0 V 380 V 5 V 0 V Basic reference. Complete with code indicating control circuit voltage a Weight kw kw kw kw kg (lb.) Maximum operating rate in starts/hour: LE3-K: and LE3-D: 30. Maximum starting time: 30 seconds 3 5.5 5.5 5.5 LE3-K065kk.60 (3.9) LE3-K095kk.60 (3.9) 7.5 7.5 7.5 or LE3-D095kk f 3.650 (8.07) 5.5 LE3-D5kk 3.650 (8.07) 8.5 LE3-D85kk 3.750 (8.67) 5 5 30 30 LE3-D35kk 5.60 (.376) 8.5 37 37 37 LE3-D05kk 8.60 (7.989) 30 55 59 59 LE3-D505kk 8.50 (7.967) 37 75 75 75 LE3-D805kk.000 (30.86) Specifications Enclosure LE3-D09 to D80 Metal, degree of protection IP 559 Control ( pushbuttons mounted on enclosure cover) LE3-D09 to D8 green Start button I red Stop/Reset button O No pushbuttons on cover LE3-D3 to D80 LE3-K06 and K09 Connections LE3-D09 to D80 A timer LA-DS imposes a delay of 0 ms ± 5 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time. Forms (mounted by Telemecanique) Pre-wired power and control circuit connections Description For use on Suffix to be added to starter reference t No pushbuttons on cover LE3-D09 to D8 A0 blue Reset button R LE3-D09 to D80 A05 green Start button I red Stop/Reset button O Neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply LE3-D3 to D80 LE3-K06 and K09 LE3-D09 to D80 A06 A59 c Overload protection by means of thermal overload relay to be ordered separately. Select appropriate overload relay for setting at 0.58 the full load rated motor current. a Coil selection LE3-K Volts AC 50/60 Hz 36 8 0 7 0/30 30 30/0 380/00 00 00/5 0 500 660/690 Code J7 B7 C7 D7 E7 F7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 LE3-D Volts AC 50/60 Hz 8 0 0/30 30 0 380/00 00 5 0 Code B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 t Example: LE3-D095F7A0. 30 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Star-Delta starters with fused disconnect switch LE3-D International applications only Wiring methods differ from typical North American practice. Contains UL listed, CSA certified, CE marked components. Assemblies are not UL listed or CSA certified. LE3-D096 Standard power ratings of squirrel cage motors q Mains voltages - delta connection 0 V 380 V 5 V 0 V Size Fuses to be fitted by customer Type am Basic reference. Complete with code indicating control circuit voltage a kw kw kw kw A kg (lb.) Maximum operating rate: 30 starts/hour. Maximum starting time: 30 seconds. 7.5 7.5 7.5 0 x 38 0 LE3-D096kk 3.900 (8.598) 5.5 0 x 38 5 LE3-D6kk 3.900 (8.598) 8.5 x 5 0 LE3-D86kk.850 (0.69) 5 5 30 30 x 58 63 LE3-D36kk 7.650 (6.865) 8.5 37 37 37 x 58 80 LE3-D06kk 6.90 (37.56) 30 55 59 59 x 58 5 LE3-D506kk 7.00 (37.78) 37 75 75 75 0 60 LE3-D806kk 7.50 (60.66) Specifications Enclosure LE3-D09 to D80 Metal enclosure, degree of protection IP 559 Control ( pushbuttons on enclosure cover) LE3-D09 and D No pushbuttons on cover LE3-D8 to D80 Isolator with external operator LE3-D09 and D green Start button l red Stop/Reset button O 3-pole isolator + additional pole LA8-D5 LE3-D8 tp D80 3-pole isolator and circuit breaker GB-CB08 Connections LE3-D09 to D80 Pre-wired power and control circuit connections A timer LA-DS imposes a delay of 0 ms ± 5 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time. Weight Forms (mounted by Telemecanique) Description For use on Suffix to be added to starter reference f No pushbuttons on cover LE3-D09 and D A0 blue Reset button R LE3-D09 to D80 A05 green Start button I red Stop/Reset button O neutral terminal Fitted as standard on starters ordered with 0 V (U7) control supply. LE3-D8 to D80 LE3-D09 to D80 A06 A59 c Overload protection by thermal overload relay, to be ordered separately. Select appropriate overload relay for setting at 0.58 the full load rated motor current. a Coil selection Volts 8 0 0/30 30 0 380/00 00 5 0 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 Other voltages: see replacement coil pages 07/ to 07/7. f Example: LE3-D096F7A0. LE3-D06 7/98 998 Square D All Rights Reserved 3

D-Line Contactors, Overload Relays and Accessories Spare parts and accessories International applications only Operating heads for Start and Stop/Reset pushbuttons Description For use on Unit reference Weight kg (lb.) LE-D09 and D ZA-BA33 c 0.05 (0.033) LE-D8 LA9-D79 0.05 (0.033) ZA-BA33 ZA-BL3 Flush green I Projecting red O Mounting kit for heads ZA-BA33 and ZA-BL3 Operating heads for Reset pushbuttons LE-D5 LA9-D69 0.05 (0.033) LE-D09, D and D5 LA9-D5 0.05 (0.033) LE-D8 LA9-D8 0.05 (0.033) LE-D09 and D ZA-BL3 c 0.00 (0.0) LE-D8 LA9-D8 0.00 (0.0) LE-D5 LA9-D5 0.00 (0.0) LE-D09 and D LA9-D09 0.00 (0.0) LE-D8 LA9-D8 0.00 (0.0) LE-D5 LA9-D5 0.00 (0.0) LE-D09 and D LA9-D090 0.00 (0.088) LE-D09 and D ZA-BA639 a 0.05 (0.033) LE-D8 LA9-D88 0.05 (0.033) LA9-D098 Flush blue R LE-D5 LE-D095 and D5 LE-D09 and D LE-D85 LE-D8 LE-D55 LA9-D58 0.05 (0.033) LA9-D098 0.05 (0.033) LA9-D88 0.05 (0.033) LE-D5 LA9-D58 0.05 (0.033) Mounting kit for head ZA-BA639 LE-D09 and D LA9-D0935 0.05 (0.033) Contact blocks LE-D09 and D LA9-E0906 q 0.05 (0.033) LA9-D0906 LA9-D09906 N.O. spring return LE-D095 and D5 LE-D09 and D LE-D8 and D5 LE-D85 and D55 LE-D8 and D5 LA9-D09906 f 0.05 (0.033) LA9-D6906 q 0.05 (0.033) LE-D09 and D LA9-E0975 t 0.05 (0.033) N.C. spring return LE-D5 LE-D09 to D5 LA9-D0975 t 0.00 (0.0) Contact block support LE-D09 and D LA9-D0909 0.05 (0.033) Accessories Start pushbutton latching device for local stay put operation LE-D8 and D5 LE-D8 and D5 LA9-D09907 0.05 (0.055) Shim LE-D8 LA9-D83 0.00 (0.0) Enclosure sealing kit LE-D09 and D LA9-E099 0.00 (0.0) LE-D8 and D5 LE-D095 to D55 LE-D09 to D5 DE-DS9 0.00 (0.0) Vacuum valve (sold in lots of 5) LE and LE-D09 to D5 LA9-D90 0.050 (0.0) c Remember to order mounting kit LA9-D090 ( kit only required for both heads). a Remember to order mounting kit LA9-D0935. q Color reference green. f Color reference black. t Color reference red. LA9-D09907 3 998 Square D All Rights Reserved 7/98

International applications only D-Line Contactors, Overload Relays and Accessories Spare parts and accessories Empty enclosures for across-the-line starters without off-load isolator For use with Type c Pushbutton operating head(s) or blanking plug(s) mounted on the cover Reference Weight kg (lb.) Without a DE-DS5A0 f 0.30 (0.98) DE-DS53A06 LE-D09, D LE-D88 q LE-D58 LE-D093, D3 LE-D85 q LE-D55 Double insulated degree of protection IP 9 Double insulated degree of protection IP 7 Double insulated degree of protection IP 659 Double insulated degree of protection IP 557 flush blue head R DE-DS5A05 f 0.30 (0.98) flush green head I projecting red head O DE-DS5A06 f 0.30 (0.98) blanking plugs (select or heads from previous page if required) DE-DS68A0 0.585 (.90) Without a DE-DS53A0 f 0.30 (0.98) flush blue head R DE-DS53A05 f 0.30 (0.98) flush green head I projecting red head O DE-DS53A06 f 0.30 (0.98) blanking plugs (select or heads from previous page if required) Empty enclosures for D.O.L. starters with off-load isolator DE-DS65A0 0.585 (.90) blanking plugs DE-DS56A0.330 (.93) DE-DS65A0 LE-D096, D6 LE-D86, D56 Double insulated degree of protection IP 557 Double insulated degree of protection IP 557 flush blue head R blanking plug flush green head I projecting red head O blanking plugs (select or heads from previous page if required) Empty enclosures for reversing starters without off-load isolator DE-DS56A05.330 (.93) DE-DS56A06.330 (.93) DE-DS66A0.30 (3.5) blanking plugs DE-DS55A0.330 (.93) LE-D095, D5 Double insulated degree of protection IP 557 flush blue head R blanking plug flush green head I flush green head II projecting red head O DE-DS55A05.330 (.93) DE-DS55A.330 (.93) LE-D85, D55 Double insulated degree of protection IP 557 blanking plugs (can be fitted with flush blue head R selected from previous page) DE-DS65A0.30 (3.5) DE-DS56A05 c Dimensions and knock-outs for cable glands: see pages 3 to 37. a Cover can be supplied with cut-outs for fitting, or 3 operating heads, see page 3. q Order shim LA9-D83 separately: see page 3. f Variant: to order an enclosure with knock-outs for 6 mm plastic cable glands, add suffix A0 to the reference. Example : DE-DS53A06A0. DE-DS55A 7/98 998 Square D All Rights Reserved 33

D-Line Contactors, Overload Relays and Accessories Dimensions LEkD: International applications only Enclosed D-Line starters without Fused Disconnect Switch LE-D093, D3 LE-D09, D LE-D85, D55 LE-D88, D58 LE-D35, D05, D505, D655 LE3-D095, D5, D85 xø5.5 xø5.5 0 0 66 = = 88 = 50 = 35 85 = = 0 = 65 = 50 6 () 3 xø7.7 = 05 = 8 = 95 = () 50 for LE-DkkkkkA0 (without pushbuttons). LE-D095, D5, D85, D55 xø5.5 LE-D805, D955 LE-D35, D05, D505, D655 LE3-D35 LE-D805, D955 LE3-D05, D505 c c 80 = = = 60 = 65 c 307 xø7.7 = 65 57 = = 65 = 65 c 307 xø7.7 = 65 57 = = 65 = LE- c c c Note: Dimensions are expressed in millimeters. D095 3 35 LE-Dkkk 76 ( pushbuttons I and O ) (mm X.039 = inches) D5 3 35 LE-DkkkkkA0 65 (without pushbuttons) D85 7 LE-Dkkk 69 ( reset pushbutton R ) D55 7 LE3-Dkkk 65 (without pushbuttons) () 90 for LE3-Dkkk (without pushbuttons). LE3-D805 Knock-outs or blanking plugs for cable glands (gland size in mm, P = Plastic) = 35 = Type of enclosure At top At bottom LE-D093, D09 LE-D3, D LE-D095, D5 x 3 P x 3 P 00 () 57.5 350 35 = LE-D85, D88 LE-D55, D58 LE-D85, D55 x 3 P and x 6 P x 6 P LE-D35, D05 x 3 P and x P x 3 P and x P LE-D35 to D655 LE-D505, D655 x 3 P and x 9 P x 3 P and x 9P xm8x5 LE-D805, D955 LE-D805, D955 x 3 P and x 36 P x 3 P and x 36P = LE3-D095, D5 x 6 P and x 3 P x 6 P and x 3P LE3-D85 x P and x 3 P x P and x 6P 0 8 350 00 57.5 LE3-D35 LE3-D05 x P x 9 P x P, x 3 P and x 6 P x 9 P, x 3 P and x P LE3-D505 x 36 P x 36 P, x 3 P and x 9 P LE3-D805 x 36 P x 3 P and 3 x 36 P () + mm with blanking plugs. 3 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Dimensions LEkD: International applications only Enclosed D-Line starters with Fused Disconnect Switch LE-D096, D6, D86, D56 xø5.5 LE-D096, D6, D86 LE3-D096, D6 c c 80 = = = 60 = 3 50 6 () 3 = xø7.7 05 = 8 95 = = 3 LE- c c () 5 for LE-Dkkk ( reset pushbutton R ). D09, D 3 39 D8, D5 5 LE-D56, D36 LE3-D86, D36 LE-D36, D06, D506, D656 b xø7.7 H = b xø7.7 H = = c c () = G a = = 3 c c () = G a = 3 LE- a b c c G H LE3- a b c c G H LE- a b c c G H D56 57 307 65 69 65 65 D86 57 307 65 65 65 65 D36 307 57 65 76 65 65 D06, 506, D36 87 367 90 9 95 5 D36 87 367 90 90 95 5 367 87 90 0 5 95 656 () c = c for LE3-Dkkk (without pushbuttons). () c = c for LE-Dkkkkkk A0 (without pushbuttons). LE-D06, D506, D656, D806 LE3-D06, D506, D806 LE-D806 = a-75 = 3 Knock-outs or blanking plugs for cable glands (gland size in mm, P = Plastic) Type of At top enclosure At bottom b () b+57.5 b-50 xm8x5 b-75 = LE-D096, D6 x 3 P x 3 P LE-D86, D56 x 3 P and x 6 P x 6 P LE-D096 to D56 x 3 P and x 6 P x 3 P and x 6 P LE-D36, D06 LE-D36, D06 x 3 P and x P x 3 P and x P LE-D506, D656 LE-D506, D656 x 3 P and x 9 P x 3 P and x 9 P = LE-D806 LE-D806 x 3 P and x 36 P x 3 P and x 36 P c c a-50 a a+57.5 LE3-D096, D6 x 3 P and x 6 P x 3 P and x 6 P LE3-D86, D36 x P x 3 P, x 6 P and x P () + mm with blanking plugs. LE3-D06 x 9 P x 3 P, x P and x 9 P LE- a b () c c LE3-D506 x 36 P x 3 P, x 9 P and x 36 P D06, D506, D656 300 00 0 8 LE3-D806 x 36 P x 3 P and 3 x 36 P D806 00 00 0 8 Note: Dimensions are expressed in millimeters. LE3- D06, D506 00 500 0 8 (mm X.039 = inches) D806 500 700 53 69 LE- D806 00 00 0 8 7/98 998 Square D All Rights Reserved 35

D-Line Contactors, Overload Relays and Accessories Dimensions LEkK: International applications only Enclosed K-Line starters without Fused Disconnect Switch LE-K06, K09 (except A3) xø5.3 LE-K06kkkA3, K09kkkA3 LE-K06, K09 LE3-K06, K09 9 0 xø5.3 63 3 50 65 0 0 = 80 = 6 8 75 () () For LE Enclosed K-Line starters with Fused Disconnect Switch LE-K06, K09 LE8-K06, K09 9 0 xø5.3 3 50 65 6 0 8 75 () () For LE8 Note: Dimensions are expressed in millimeters. Knock-outs or blanking plugs for cable glands (gland size in mm, P = Plastic) (mm X.039 = inches) Type of enclosure At top At bottom LE-K x 3 P x 3 P LE-KkkA3 x 3 P and x 6 P x 3 P and x 6 P LE-K x 3 P and x 6 P x 3 P and x 6 P LE3 x 3 P and x 6 P x 3 P and x 6 P LE, LE8-K x 3 P and x 6 P x 3 P and x 6 P 36 998 Square D All Rights Reserved 7/98

LG-K and LG-D: International applications only Starters without isolator D-Line Contactors, Overload Relays and Accessories Dimensions LG-K06, K09 LG-D, D8 LG7-K06, K09, D, D8 LG8-K06, K09, K 0 xø5.3 () xø5.3 50 65 () 50 65 0 65 8 75 6 77 8 75 (3) Knock-outs or blanking plugs for cable glands () Emergency stop for starters < 3 kw Type of enclosure At top At bottom () Emergency stop for starters 3 kw LG-K and LG-D x 3 P and x 6 P x 3 P and x 6 P (3) Only for LG7 LG7-K and LG7-D x 3 P and x 6 P x 3 P and x 6 P LG8-K x 3 P and x 6 P x 3 P and x 6 P Note: Dimensions are expressed in millimeters. (mm X.039 = inches) 7/98 998 Square D All Rights Reserved 37

D-Line Contactors, Overload Relays and Accessories Wiring diagrams LE-K and LE-D: International applications only Enclosed non-reversing K-Line starters LE-K06, K09 LE-K06kkkA3, K09kkkA3 LE-K06, K09 LE-K06kkkA3, K09kkkA3 L L 3 L3 5 Q/ KM/5 KM 3 6 5 I 3 KM O KM 96 3 3 95 I U V 6 W N KM/5 O KM A A 96 95 N KM/ KM A A Enclosed non-reversing D-Line starters LE-D09 to D95 LE-DkkkkkA0 LE-D09 and D LE-D8 to D95 LE-DkkkkkA0, LE-DkkkkkA05 KM /L 3/L U V 3 W 6 5 6 5/L3 KM/5 I N KM/ 3 O KM KM 96 95 A 3 A KM/5 l N KM/ 8 7 O KM KM 96 95 A 3 A KM/5 N l O 3 96 95 KM KM A 3 KM/ A 38 998 Square D All Rights Reserved 7/98

LE-K and LE-D: International applications only Enclosed reversing K-Line starters D-Line Contactors, Overload Relays and Accessories Wiring diagrams LE-K06, K09 LE-K06, K09 Variant A05 L L L3 KM/5 KM/5 O 95 R 95 53 53 KM KM 3 5 3 5 KM 6 6 3 3 96 KM 5 5 KM KM KM KM 96 Remote Control 3 5 () () () () U V 6 W N KM/ KM A A A A KM N KM/ KM A A A A KM Enclosed reversing D-Line starters LE-D095 to D55 () For the addition of end of travel limit switches, with automatic stopping in either direction: remove the connections /KM to A/KM and /KM to A/KM LE-D35 to D955 L L L3 KM/5 R 95 L L L3 KM/5 R 3 5 96 3 95 5 3 5 96 KM KM 3 6 6 5 l 3 O KM 5 53 l l KM 53 3 5 KM 6 3 6 5 KM l 3 O 3 (53) KM (5) l l 3 3 (53) KM (5) 3 5 KM KM U V 6 W KM KM U V 6 W N KM/ KM A A A A KM N KM/ KM A A A A KM ( ) for LE-D3 7/98 998 Square D All Rights Reserved 39

D-Line Contactors, Overload Relays and Accessories Wiring diagrams LE-K, LE-D, LE8-K and LE-D: International applications only Across-the-line starters and starters for the control of distribution circuits LE-K06, K09 LE-D09 to D80 LE-DkkkkkA0 Q KM /L U 3/L 3 3 V 5/L3 6 5 6 5 6 W LE-K06, K09 LE-D09 to D5 LE-D3 to D65 LE-D80 LE-DkkkkkA0, DkkkkkA05 Q/ N KM/5 O I KM A A 96 95 3 KM Q/ 0 Q N Q/6 l 8 7 9 O Q KM KM 3 95 96 3 A A Q/ N Q/6 l 8 7 F O Q KM KM 3 95 96 3 A A Q/ N Q/ F 3 Q l O KM 3 96 95 A A KM 3 Reversing starters LE8-K06, K09 LE8-K06, K09 Variant A05 KM/5 KM/5 L L L3 3 Q R 95 Q 3 5 O 95 96 6 3 96 3 Remote Control 3 5 3 5 KM KM 6 6 53 KM 53 KM U 3 V 5 5 5 6 W N KM/ KM KM KM A A () A A () KM N KM/ KM KM () () A A KM KM A A () For the addition of end of travel limit switches, with automatic stopping in either direction: remove the connections /KM to A/KM and /KM to A/KM LE-D096 to D806 LE-D096 to D56 LE-D36 to D806 Q /L 3/L 5/L3 Q/ F 3 Q 95 Q/ F 3 Q 95 3 5 3 5 KM 6 6 KM 3 5 (5) (5) 6 96 O l 3 l l 3 KM 3 (53) KM (5) (5) 96 O l 3 l l 3 3 (53) KM 3 (53) KM 3 (53) 6 KM KM KM KM U V W N KM A A KM N KM A A KM Q/6 A A Q/6 A A ( ) for LE-D3. 0 998 Square D All Rights Reserved 7/98

LG-K, LG-D, LG7-K, LG7-D, LG8-K: International applications only Across-the-line starters D-Line Contactors, Overload Relays and Accessories Wiring diagrams LG-K06, K09, D, D8 LG-K06, K09, D, D8 380/00 V, code Q7 or 00/5 V, code N7 0/30 V, code M7 L3/L L/L L/L3 Ph Q KM/ T3 T 3 T 5 3 KM S 6 3 Q S KM 3 5 6 KM/5 KM A A U V W N M 3 c LG7-K06 LG7-K09, D, D8 LG7-K06, K09, D, D8 380/00 V, code Q7 or 00/5 V, code N7 0/30 V, code M7 /L 3/L 5/L3 /L 3/L 5/L3 D D Ph KM/ Q Q 3 KM S 3 6 KM U 3 5 V 6 F KM W 6 M 3 c U V W M 3 c 3 5 6 E E S A KM KM/5 N A Reversing starters LG8-K06 LG8-K09, K LG8-K06, K09, K 380/00 V, code Q7 or 00/5 V, code N7 0/30 V, code M7 /L 3/L 5/L3 /L 3/L 5/L3 D D Ph KM/5 Q Q S 6 KM KM 3 5 3 5 6 6 KM KM 6 6 3 5 3 5 6 E E KM KM S 0 3 5 KM 53 3 5 KM A A S 53 U V 0 W M 3 c U V W M 3 c KM KM/ N A A KM 7/98 998 Square D All Rights Reserved

D-Line Contactors, Overload Relays and Accessories Contactors -Definitions and comments Altitude Ambient air temperature Rated operational current (Ie) Rated conventional thermal current (Ith) c Permissible short time rating Rated operational voltage (Ue) Rated control circuit voltage (Uc) Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Rated operational power (expressed in kw) Rated breaking capacity a Rated making capacity a On-load factor (m) Pole impedance Electrical durability Mechanical durability The low oxygen atmosphere at high altitudes reduces the dielectric strength of the air and hence the rated operational voltage of the contactor. It also reduces the cooling effect of the air and hence the rated operational current of the contactor (unless the temperature drops at the same time). No derating is necessary up to 3000 m. Derating factors to be applied above this altitude for main pole operational voltage and current (AC supply) are as follows. Altitude 3500 m 000 m 500 m 5000 m Rated operational voltage 0.90 0.80 0.70 0.60 Rated operational current 0.9 0.90 0.88 0.86 The temperature of the air surrounding the device, measured near to the device. The operating characteristics are given: - with no restriction for temperatures between -5 and +55 C - with restrictions, if necessary, for temperatures between -50 and +70 C This is defined taking into account the rated operational voltage, operating rate and duty, utilization category and ambient temperature around the device. The current which a closed contactor can sustain for a minimum of 8 hours without its temperature rise exceeding the limits given in the standards. The current which a closed contactor can sustain for a short time after a period of no load, without dangerous overheating. This is the voltage value which, in conjunction with the rated operational current, determines the use of the contactor or starter, and on which the corresponding tests and the utilization category are based. For 3-phase circuits it is expressed as the voltage between phases. Apart from exceptional cases such as rotor short-circuiting, the rated operational voltage Ue is less than or equal to the rated insulation voltage Ui. The rated value of the control circuit voltage, on which the operating characteristics are based. For AC applications, the values are given for a near sinusoidal wave form (less than 5% total harmonic distortion). This is the voltage value used to define the insulation characteristics of a device and referred to in dielectric tests determining leakage paths and creepage distances. As the specifications are not identical for all standards, the rated value given for each of them is not necessarily the same. The peak value of a voltage surge which the device is able to withstand without breaking down. The rated power of the standard motor which can be switched by the contactor, at the stated operational voltage. This is the current value which the contactor can break in accordance with the breaking conditions specified in the IEC standard. This is the current value which the contactor can make in accordance with the making conditions specified in the IEC standard. This is the ratio between the time the current flows (t) and the duration of the cycle (T) m = t T Cycle duration: duration of current flow + time at zero current The impedance of one pole is the sum of the impedance of all the circuit components between the input terminal and the output terminal. The impedance comprises a resistive component (R) and an inductive component (X=Lω). The total impedance therefore depends on the frequency and is normally given for 50 Hz. This average value is given for the pole at its rated operational current. This is the average number of on-load operating cycles which the main pole contacts can perform without maintenance. The electrical durability depends on the utilization category, the rated operational current and the rated operational voltage. This is the average number of on-load operating cycles (i.e. with zero current flow through the main poles) which the contactor can perform without mechanical failure c Conventional thermal current, in free air, conforming to IEC standards. a For AC applications, the breaking and making capacities are expressed by the rms value of the symmetrical component of the short-circuit current. Taking into account the maximum asymmetry which may exist in the circuit, the contacts therefore have to withstand a peak asymmetrical current which may be twice the rms symmetrical component. NOTE: these definitions are extracted from standard IEC 97-. t T 998 Square D All Rights Reserved 7/98

D-Line Contactors, Overload Relays and Accessories Contactors -Definitions and comments 7/98 998 Square D All Rights Reserved 3

and are registered trademarks of Underwriters Laboratories, Inc. is a registered trademark of Canadian Standards Association FINGERSAFE is a trademark of Square D Company Square D Company 800 Hwy. 6 East Knightdale, NC 755 (99) 66-367 Seriplex is a trademark of Square D Company Square D and are registered trademarks of Square D Company. Catalog No. 850CT970 July 998 998 Square D All Rights Reserved.