Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications



Similar documents
VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

32VFD Variable Frequency Drives for Centrifugal Chillers

HVAC DRIVE H300 HVAC Drive for Building Automation

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

SECTION VARIABLE FREQUENCY DRIVES

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Specifying a Variable Frequency Drive s

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

TR1 Series VFD. Variable Frequency Drives TR1-SLB005-EN

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Principles of Adjustable Frequency Drives

A1000 Cheat Sheet (Open Loop Vector)

Product Bulletin. ABB drives for HVAC applications ACH550, 1 to 550 Hp

vacon x series rugged drives for the real world

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Variable Speed Drives

EnVisioneering.

Altivar 212 Drive. Selection Guide. Make the most of your energy SM

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

FREQUENCY CONTROLLED AC MOTOR DRIVE

VLT 6000 HVAC. Contents

MC1000 Series Installation and Operation Manual

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Easy to connect - Easy to configure Easy to install

SmartVFD HVAC and BYPASS

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

GPD 506/P5 Start-up Procedure and Checklist

... Electronic Softstarter...

Diesel Engine Driven Generators Page 1 of 6

EET272 Worksheet Week 9

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Frequency Converter Fv

HVAC BUILDING SERVICES

NX Series Inverters. HVAC Pocket Programming Guide

Limited Service Fire Pump Controllers Features

Variable Speed Drives

How To Use The Vacon 0 Machinery

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Uninterruptible Power Supply

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Permissible ambient temperature Operation Storage, transport

PUMP CONTROL. AC Variable Speed Drive PUMP CONTROL. Energy efficient pumping with. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

TABLE OF CONTENTS. Fig. 1 EV Pictorial Wiring Diagram 5. Section 2 Inverter Option Modules 6

Reliance Electric GV3000/SE Industrial AC Drive

Number 1 in efficiency

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DC Motor control Reversing

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Products and solutions for lifting systems

Pulse Width Modulated (PWM) Drives. AC Drives Using PWM Techniques

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Understanding Variable Speed Drives

HVAC Applications. VFD considerations for HVAC systems...

Analog Servo Drive 25A8

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

J1000. System configuration

Fundamentals of Inverter Fed Motors

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

Unidrive M Energy Savings

What Is Regeneration?

Products and solutions for pumping, irrigation and piping

Pulse Width Modulated (PWM)

with Electronic Assistant

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Thyristor-controlled power supplies and battery chargers

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

vacon 100 hvac for indoor climate control

PowerFlex 525 AC Drive. The Next Generation of PowerFlex Compact Drives

PanelView Plus 7 Performance Operator Interface. 7-inch to 19-inch Displays

PRODUCT PROFILE FEATURES

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

1 Application Description Objective Goals... 3

Transcription:

Z1000 HVAC Drive 3 HP to 500 HP Fan and Pump Applications The Z1000 variable speed drive is designed for building automation applications such as fans, pumps, and cooling towers through 500 HP. The Z1000 features an easy-to-read LCD keypad that provides Hand- Off-Auto interface and a real time clock. These features make the Z1000 perfect for most building automation applications that require reliable motor control. Harmonic Mitigation* Built-in 5% line impedance for input harmonic reduction. Noise Filter* On board EMI/RFI filter complies with IEC 61800-3 restricted distribution for first environment. Serial Communications Embedded BACnet communications (BTL Certified), along with Modbus/ Memobus. Ratings Plenum Rated (UL 1995). Seismic Rated (IBC 2006 - Certification 12/2011). Made with RoHS compliant materials. Internal Real-Time Clock Time and date stamping for events, along with timer controls for starting stopping and speed changes without the need for external controls. PI Feature Maintains a set point for closed loop control of fans and pumps for pressure, flow or temperature regulation and eliminates the need for a closed loop output signal from a BAS. Independent PI to control an external device in the system. LCD Operator 5-Line 16 character alpha-numeric, easy to read and understand display, with Hand-Off-Auto functions. Carrier Frequency 5 khz carrier frequency with dynamic noise control for quiet motor operation. Application Macros Choose from pre-configured set up macros to match the application for quick and easy set up. Sealed Heatsink Allows for drive to be mounted in a NEMA 12 enclosure with heatsink external. Specifications Overload Capacity 110% for 60 seconds, Output Frequency 0.01 to 240 Hz Control Methods V/Hz Control Open Loop Vector Control for Permanent Magnet motors Motor Types Squirrel Cage Induction Interior Permanent Magnet (IPM) Enclosures NEMA Type 1 / IP20 : 3-100 HP 208V and 3-250 HP 480V Open Type / IP00 : 125-150 HP 208V and 300-500 HP 480V Ambient Operating Temperature -10 C to 40 C (14 F to 104 F) Global Certification UL, CSA, CE, RoHS Standard I/O Seven Multi-Function Programmable Digital Inputs (24Vdc) Two Multi-Function Programmable Analog Inputs (0-10VDC or 4-20mA) One Fault Relay Output (Form C - 2 Amps at 250Vac max) Three Multi-Function Programmable Relay Output (Form A - 2 Amps @ 250Vac max) Two Multi-Function Programmable Analog Outputs (0-10Vdc or 4-20mA) One 24 Vdc, 150 ma Transducer or Transmitter Power Supply for customer use Network Communications Built-in BACnet, RS485/422 - Programmable up to 76.8 kbps Optional: LonWorks, Metasys, APOGEE FLN, EtherNet/IP * Available only as options, 300-500HP ratings. Yaskawa America, Inc. Tel: 1-800-YASKAWA (927-5292) www.yaskawa.com Drives & Motion Division

Z1000 HVAC Drive 3 HP to 500 HP Fan and Pump Applications Model Number CIMR-ZU2A Rated Output Current (Amps) HP Dimensions (in.) H W D Enclosure Type FREE Estimating Tools Energy Savings Predictor 0011FAA 10.6 3 0017FAA 16.7 5 0024FAA 24.2 7.5 0031FAA 30.8 10 0046FAA 46.2 15 0059FAA 59.4 20 0075FAA 74.8 25 0088FAA 88.0 30 0114FAA 114 40 0143FAA 143 50 0169FAA 169 60 0211FAA 211 75 0273FAA 273 100 0343AAA 343 125 0396AAA 396 150 14.1 8.6 4.9 17.6 9.2 20.1 7.9 9.4 21.3 10.0 10.3 30.5 13.4 15.7 31.5 19.7 13.8 IP20 NEMA Type 1 IP00 Open-Type Harmonics Estimator Carbon Footprint Calculator Energy Savings Predictor Software Harmonics Estimating Tool Yaskawa Electric America, Inc. Tel: 1-800-YASKAWA (927-5292) www.yaskawa.com 2011 All Rights Reserved Model Number CIMR-ZU4A Rated Output Current (Amps) HP Dimensions (in.) H W D Enclosure Type 0005FAA 0008FAA 4.8 7.6 3 5 14.1 8.6 0011FAA 11.0 7.5 0014FAA 14.0 10 4.9 0021FAA 21.0 15 17.6 9.2 0027FAA 27.0 20 0034FAA 34.0 25 0040FAA 40.0 30 20.1 7.9 9.4 0052FAA 52.0 40 0065FAA 65.0 50 0077FAA 77.0 60 21.3 10 10.3 0096FAA 96.0 75 0124FAA 124 100 27.6 11.8 11.4 0156FAA 156 125 0180FAA 180 150 30.5 14.2 15.7 0240FAA 240 200 0302FAA 302 250 41.1 16.1 18.9 0361AAA 361 300 37.4 19.7 0414AAA 414 350 0480AAA 480 400 14.6 44.9 26.4 0515AAA 515 450 0590AAA 590 500 IP20 NEMA Type 1 IP00 Open-Type itunes App Energy savings app for the iphone and the ipod touch is available at itunes.com - search for Yaskawa. Document Number: FL.Z1000.01 10-15-2011 2011 Yaskawa America, Inc. Tel: 1-800-YASKAWA (927-5292) www.yaskawa.com Drives & Motion Division

Z1000 Model Number Designation Page 1 of 1 Global Sites Home Site Map Contact Us Search Advanced Search Products Support Downloads Sales Training Industries/Applications About Us Partner Info Login Home > Commercial HVAC Drives > Model Number Designation Login Z1000 Drive Z1000 Bypass Z1000 Configured E7 Drive E7S Slim Configured Package E7C Drive Configured E7N Narrow Bypass Package E7L Drive Bypass E7B Drive Bypass E7E Drive Engineered Model Number Designation for Z1000 Drive Find Local Contact Sales Rep Distributor Service Center Enter Request Application and Product Help Literature Quote Technical Support View Models and Ratings Home Site Map Contact Us Search Copyright 2012 Yaskawa America, Inc. All Rights Reserved. Conditions of Use Privacy Policy Drives & Motion Division http://www.yaskawa.com/site/products.nsf/productdetailpages/commercial%20hvac%2... 9/19/2012

GENERAL Date Customer Job Name P.O. / S.O. 8/21/2012 PROFESSIONAL MECHANICAL SHORES The Z1000 is a high performance PWM (pulse-widthmodulated) AC drive. Three-phase input line power is converted to a sine-coded, variable frequency output, which provides optimum speed control of any conventional squirrel cage induction motor and permanent magnet motor. The use of IGBTs (Insulated Gate Bipolar Transistors), with a carrier frequency range of 1 khz to 12.5 khz, permits quiet motor operation. This drive has one control logic board for all horsepower ratings. Printed circuit boards employ surface mount technology, providing both high reliability, and small physical size of the printed circuit assemblies. The dual 32 bit microprocessors deliver the computing power necessary for complete three phase motor control in building automation systems. Operating Principle: Input three phase AC line voltage is first rectified to a fixed DC voltage. Using pulse width modulation (PWM) inverter technology, the DC voltage is processed, to produce an output waveform in a series of variable-width pulses. Unique firmware algorithms optimize motor magnetization through control of voltage, current and frequency applied to generate a nearly sinusoidal output waveform. STANDARDS UL 508C (Power Conversion) CSA 22.2 No. 14-95 (Industrial Control Equipment) UL 1995 (Plenum) CE mark 2006/95/EC LVD CE mark 2004/108/EC IEC 61800-5-1 (LVD) EN 61800-3 IEC 529 IEEE C62.41 BTL Listed UL, cul listed; CE marked ENVIRONMENTAL & SERVICE CONDITIONS Ambient service temperature: Variable Frequency Drive (VFD) Z1000 Mechanical Specification Submittal (For NEMA 1 Rated Drives) NEMA 1 (IP20): -10 C to 40 C (14 F to 104 F) Ambient storage temperature: -20 C to 70 C (-4 F to 158 F) Humidity: 0 % to 95 %, non-condensing Altitude: to 1000 meters (3300 feet), higher by derating Service factor: 1.0 Vibration: 9.81m/s 2 (1 G) maximum at 10 to 20 Hz, 2.0 m/s 2 (0.2 G) at 20 Hz to 55 Hz. Plenum mounting capable (IP20) RoHS Compliant QUALITY ASSURANCE In circuit testing of all printed circuit boards is conducted, to ensure proper manufacturing. Final printed circuit board assemblies are functionally tested, via computerized test equipment. All fully assembled controls are computer tested with induction motor loads to assure unit specifications are met. The average MTBF (Mean Time Between Failure) is 28 years CONSTRUCTION Input Section - VFD power input stage converts three phase AC line power into a fixed DC voltage, via a solid state full wave diode rectifier, with MOV (Metal Oxide Varistor) surge protection. An internal 5% DC bus reactor reduces harmonics for cleaner power. Intermediate Section - DC bus maintains a fixed DC voltage, with filtering and short circuit protection, as a DC supply to the VFD output section. It is interfaced with the VFD diagnostic logic circuit, to continuously monitor and protect the power components. Output Section - Insulated Gate Bipolar Transistors (IGBTs) convert DC bus voltage to a variable frequency and voltage, utilizing a PWM sine-coded output to the motor. IGBT output allows motor noise, at 60 Hz, to measure less than 2 db (@ 1 meter) above that resulting from across the line operation. Power and control electronics housings: NEMA 1 (IP20) wall-mounted enclosure: 208 V, 3 thru 100 HP; 480 V, 3 thru 250 HP Z1000 Subs 10/25/2011 1

CONSTRUCTION (continued) Microprocessor based control circuit Non-Volatile memory (NV RAM); all programming memory is saved when the VFD is disconnected from power. Current transformers detect the output current for motor control and protective functions Digital operator keypad and display, with copy function, provides local control and readout capability: Hand/Off/Auto commands Speed Reference command Reset command Easy to remove heat sink cooling fan with programmable on/off control USB Type B port for quick and easy PC Connection PRODUCT FEATURES Displacement power factor of.98 throughout the motor speed range Input phase insensitive; sequencing of the three phase input is unnecessary Internal EMI/RFI filter complies with IEC 61800-3 restricted distribution for first environment Built-In real time clock for time and date stamping events along with timer functions for starting, stopping and speed changes without the need for external controls Volt meter, ammeter, kilowatt meter elapsed run time meter and heat sink temperature monitoring functions Two internal (PI) Controls 1. Drive internal PI closed loop control with selectable engineering units 2. Independent PI control for use with external device Differential PI feedback feature Sleep function in both closed loop and open loop control Feedback signal low pass filter Feedback signal loss detection and selectable response strategy Feedback signal inverse and square root capability 24 Vdc, 150ma transmitter power supply Input and output terminal status indication Diagnostic fault indication VFD efficiency: 96% at half-speed; 98% at full-speed S-curve soft start / soft stop capability Run/Fault output contacts Serial communication loss detection and selectable response strategy Up/Down floating point control capability Controlled speed range of 40:1 Critical frequency rejection capability: 3 selectable, adjustable bandwidths 100% starting torque capability, available from 3 Hz to 60 Hz Remote speed reference (speed command) signal: 0 to 10 VDC (20 k ) 4 to 20 ma DC (250 ) Adjustable carrier frequency, from 1 khz to 12.5 khz Dynamic noise control for quiet motor operation Programmable security code 7 programmable multi-function input terminals (24Vdc) providing 60+ programmable features, including: Customer Safeties BAS / Damper Interlock Emergency Override Preset Speed PI control enable / disable 3 programmable multi-function output relays (Form A rated 2 amps @ 250Vac & 30Vdc), providing 50+ functions, including: Damper control Hand / Auto Status Contactor Control for External Bypass Overtorque/undertorque detection Serial communication status No load detection (broken belt alert) One fixed Fault form C output relay (Rated 2 amps @ 250Vac & 30Vdc) 7 preset speeds Built-in BACnet protocol along with Modbus/Memobus. Protocol are accessible via RS-422/485 communication, which is standard Stationary motor auto-tuning Kinetic Energy Braking (KEB) function stops the motor in up to half the time it would take without this function. LCD keypad: Hand/Off/Auto functions with a built-in copy feature, Motor preheat function Flash upgradeable firmware Customizable monitor display Heat sink over temperature speed fold-back feature Bumpless transfer between Hand and Auto modes Emergency override can be used as smoke purge function Fan failure detection and selectable drive action Z1000 Subs 10/25/2011 2

OPERATION Output frequency and speed display can be programmed for other speed-related and control indications, including: RPM, CFM, GPM, PSI, in WC, % of maximum RPM or custom Power loss ride-thru (2 seconds capable) Time delay on start, peak avoidance VFD accepts either a direct acting or a reverse acting speed command signal Bi-directional Speed Search capability, in order to start into a rotating load. Two types: current detection and residual voltage detection DC injection braking, to prevent fan wind milling Remote Run/Stop command input Two programmable 0 to 10 VDC or 4-20ma analog outputs, proportional to drive monitor functions including: output frequency, output current, output power, PI feedback, output voltage and more.. 5-Line 16 Character LCD display provides readout functions that include: output frequency, output voltage, output current, output power, DC bus voltage, interface terminal status, PI feedback and fault status. Programmable HVAC specific application macros Over 100 programmable functions, resettable to factory HVAC presets User parameter initialization, re-establish project specific parameters Ramp-to-stop or coast-to-stop selection Auto restart capability: 0 to 10 attempts with adjustable delay time between attempts One custom selectable Volts/Hertz pattern and multiple preset Volts/Hertz patterns Auto speed reference input signal, adjustable for bias and gain While the VFD is running, operational changes in control and display functions are possible, including: Acceleration time (0 to 6000 seconds) Deceleration time (0 to 6000 seconds) Frequency reference command Hand/Off/Auto commands Monitor display Removable digital operator Automatic energy saving, reduced voltage operation PROTECTION Output current overload rating of 110 % of drive s continuous current rating for 60 seconds Output short circuit protection Current limited stall prevention (overload trip prevention) during acceleration, deceleration, and run conditions Optically isolated operator controls Fault display and last 10 faults storage Hunting prevention logic Electronic ground fault protection Electronic thermal motor overload protection (UL approved) DC bus charge indication Heat sink over temperature protection Cooling fan operating hours recorded Input/Output phase loss protection Reverse prohibit selectability Short circuit withstand rating of 100K amps RMS OPTIONS LonWorks Interface EtherNet/IP Siemens Apogee FLN Metasys N2 Z1000 Subs 10/25/2011 3