Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

Similar documents
IV. Three-Phase Induction Machines. Induction Machines

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

SYNCHRONOUS MACHINES

Lecture 6: AC machinery fundamentals

Induction Motor Theory

Control of Motor Characteristics by Squirrel-Cage Rotor Design

8 Speed control of Induction Machines

CHAPTER 5 SYNCHRONOUS GENERATOR

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

DIRECT CURRENT GENERATORS

Lab 14: 3-phase alternator.

Unit 33 Three-Phase Motors

Prof. Krishna Vasudevan, Prof. G. Sridhara Rao, Prof. P. Sasidhara Rao

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Introduction. Upon completion of Basics of AC Motors you should be able to:

Motor Fundamentals. DC Motor

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

AC Induction Motor Slip What It Is And How To Minimize It

13 ELECTRIC MOTORS Basic Relations

Synchronous motor. Type. Non-excited motors

Basics of Electricity

Three-Phase Induction Motor

How To Understand And Understand The Electrical Power System

Principles of Adjustable Frequency Drives

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Lab 8: DC generators: shunt, series, and compounded.

THREE-PHASE INDUCTION MOTOR March 2007

Direct Current Motors

How the efficiency of induction motor is measured?

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

Application Information

Electric Motor Brake Horsepower Calculations

Data Sheet. AC Industrial Electric Motors

USER MANUAL THE RESOLVER

Synchronous generators are built in large units, their rating ranging from tens to hundreds of megawatts.

Outline. Turbine Generators. Generator History 3/25/2014

FREQUENCY CONTROLLED AC MOTOR DRIVE

Principles and Working of DC and AC machines

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Motors and Generators

Chapter 6. Synchronous Machines

AC Generators and Motors

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

chapter6 Electrical machines and motors Unit 1 outcome 6

INSTRUMENTATION AND CONTROL TUTORIAL 2 ELECTRIC ACTUATORS

The DC Motor/Generator Commutation Mystery. Commutation and Brushes. DC Machine Basics

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

TERMINAL MARKINGS AND CONNECTIONS PART WINDING START

SIMULATION AND SPEED CONTROL OF INDUCTION MOTOR DRIVES

Technical Guide No High Performance Drives -- speed and torque regulation

How to Optimize Performance and Minimize Size in High Speed Applications High Performance Brushless DC Motors

AC Generators. Basic Generator

Module Title: Electrotechnology for Mech L7

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

C Standard AC Motors

WIND TURBINE TECHNOLOGY

SHIP SERVICE GENERATORS (AC)

DYNAMIC MODEL OF INDUCTION MOTORS FOR VECTOR CONTROL. Dal Y. Ohm Drivetech, Inc., Blacksburg, Virginia

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

USE OF ARNO CONVERTER AND MOTOR-GENERATOR SET TO CONVERT A SINGLE-PHASE AC SUPPLY TO A THREE-PHASE AC FOR CONTROLLING THE SPEED OF A THREE-PHASE INDUCTION MOTOR BY USING A THREE-PHASE TO THREE-PHASE CYCLOCONVERTER

ET 332b Ac Electric Machines and Power Systems

Traditional Design of Cage Rotor Induction Motors. Ronald G. Harley and Yao Duan Georgia Institute of Technology November, 2009

Chapter 4.5: Electric Motors, Variable Speed Drives

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5

Three phase circuits

On the Influence of Stator Slot shape on the Energy Conservation Associated with the Submersible Induction Motors

NATIONAL CERTIFICATE (VOCATIONAL)

Chapter 12: Three Phase Circuits

INDUCTION REGULATOR. Objective:

Inductance. Motors. Generators

Chapter 22: Electric motors and electromagnetic induction

Section 10. Application Manual for NEMA Motors. Special Applications

THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.

Direction of Induced Current

AN887. AC Induction Motor Fundamentals INTRODUCTION BASIC CONSTRUCTION AND OPERATING PRINCIPLE. Stator

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

Understanding the Alternator

We will discuss common industrial applications with guides for the proper use of electric motors on these.

5. Measurement of a magnetic field

INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2

Understanding Energy Efficient Motors

THIS paper reports some results of a research, which aims to investigate the

Full representation of the real transformer

VARIABLE FREQUENCY DRIVES THEORY, APPLICATION, AND TROUBLESHOOTING

Three-phase AC circuits

Transformer circuit calculations

PART I THEORY, CONSTRUCTION, AND OPERATION

Physical Address: City: State: Zip Code:

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

Transcription:

Induction Motors

Introduction Three-phase induction motors are the most common and frequently encountered machines in industry - simple design, rugged, low-price, easy maintenance - wide range of power ratings: fractional horsepower to 10 MW - run essentially as constant speed from no-load to full load - Its speed depends on the frequency of the power source not easy to have variable speed control requires a variable-frequency power-electronic drive for optimal speed control

Construction An induction motor has two main parts - a stationary stator consisting of a steel frame that supports a hollow, cylindrical core core, constructed from stacked laminations (why?), having a number of evenly spaced slots, providing the space for the stator winding Stator of IM

Construction - a revolving rotor composed of punched laminations, stacked to create a series of rotor slots, providing space for the rotor winding one of two types of rotor windings conventional 3-phase windings made of insulated wire (wound-rotor)» similar to the winding on the stator aluminum bus bars shorted together at the ends by two aluminum rings, forming a squirrel-cage shaped circuit (squirrel-cage) Two basic design types depending on the rotor design - squirrel-cage: conducting bars laid into slots and shorted at both ends by shorting rings. - wound-rotor: complete set of three-phase windings exactly as the stator. Usually Y-connected, the ends of the three rotor wires are connected to 3 slip rings on the rotor shaft. In this way, the rotor circuit is accessible.

Construction Squirrel cage rotor Wound rotor Notice the slip rings

Construction Slip rings Cutaway in a typical woundrotor IM. Notice the brushes and the slip rings Brushes

Rotating Magnetic Field Balanced three phase windings, i.e. mechanically displaced 120 degrees form each other, fed by balanced three phase source A rotating magnetic field with constant magnitude is produced, rotating with a speed n sync 120 f e P rpm Where f e is the supply frequency and P is the no. of poles and n sync is called the synchronous speed in rpm (revolutions per minute)

Synchronous speed P 50 Hz 60 Hz 2 3000 3600 4 1500 1800 6 1000 1200 8 750 900 10 600 720 12 500 600

Rotating Magnetic Field

Rotating Magnetic Field

Rotating Magnetic Field B () t B () t + B () t + B () t net a b c B sin( ωt) 0 + B sin( ωt 120 ) 120 + B sin( ωt 240) 240 B M M M M sin( ωt)ˆ x 3 [0.5B sin( 120 )] ˆ M ωt x [ BM 2 sin( ωt 120 )] yˆ 3 [0.5B sin( 240 )] ˆ M ωt x+ [ BM 2 sin( ωt 240 )] yˆ

Rotating Magnetic Field 1 3 1 3 Bnet ( t) [ BM sin( ωt) + BM sin( ωt) + BM cos( ωt) + BM sin( ωt) BM cos( ωt)]ˆ x 4 4 4 4 3 3 3 3 + [ BM sin( ωt) BM cos( ωt) + BM sin( ωt) BM cos( ωt)]ˆ y 4 4 4 4 [1.5B sin( ωt)] xˆ [1.5B cos( ωt)] yˆ M M

Rotating Magnetic Field

Principle of operation This rotating magnetic field cuts the rotor windings and produces an induced voltage in the rotor windings Due to the fact that the rotor windings are short circuited, for both squirrel cage and wound-rotor, and induced current flows in the rotor windings The rotor current produces another magnetic field A torque is produced as a result of the interaction of those two magnetic fields τ kb B ind R s Where τ ind is the induced torque and B R and B S are the magnetic flux densities of the rotor and the stator respectively

Induction motor speed At what speed will the IM run? - Can the IM run at the synchronous speed, why? - If rotor runs at the synchronous speed, which is the same speed of the rotating magnetic field, then the rotor will appear stationary to the rotating magnetic field and the rotating magnetic field will not cut the rotor. So, no induced current will flow in the rotor and no rotor magnetic flux will be produced so no torque is generated and the rotor speed will fall below the synchronous speed - When the speed falls, the rotating magnetic field will cut the rotor windings and a torque is produced

Induction motor speed So, the IM will always run at a speed lower than the synchronous speed The difference between the motor speed and the synchronous speed is called the Slip Where n slip slip speed n sync speed of the magnetic field mechanical shaft speed of the motor n m n n n slip sync m

The Slip Where s is the slip s n sync n sync Notice that : if the rotor runs at synchronous speed s 0 if the rotor is stationary s 1 Slip may be expressed as a percentage by multiplying the above eq. by 100, notice that the slip is a ratio and doesn t have units n m

Induction Motors and Transformers Both IM and transformer works on the principle of induced voltage - Transformer: voltage applied to the primary windings produce an induced voltage in the secondary windings - Induction motor: voltage applied to the stator windings produce an induced voltage in the rotor windings - The difference is that, in the case of the induction motor, the secondary windings can move - Due to the rotation of the rotor (the secondary winding of the IM), the induced voltage in it does not have the same frequency of the stator (the primary) voltage

Frequency The frequency of the voltage induced in the rotor is given by P n fr 120 Where f r the rotor frequency (Hz) P number of stator poles n slip speed (rpm) f r P ( ns nm) 120 P sns sfe 120

Frequency What would be the frequency of the rotor s induced voltage at any speed n m? f r sf e When the rotor is blocked (s1), the frequency of the induced voltage is equal to the supply frequency On the other hand, if the rotor runs at synchronous speed (s 0), the frequency will be zero

Torque While the input to the induction motor is electrical power, its output is mechanical power and for that we should know some terms and quantities related to mechanical power Any mechanical load applied to the motor shaft will introduce a Torque on the motor shaft. This torque is related to the motor output power and the rotor speed τ load P ω out m Nm. and ω m 2π n 60 m rad / s

Horse power Another unit used to measure mechanical power is the horse power It is used to refer to the mechanical output power of the motor Since we, as an electrical engineers, deal with watts as a unit to measure electrical power, there is a relation between horse power and watts hp 746 watts

Example A 208-V, 10hp, four pole, 60 Hz, Y-connected induction motor has a full-load slip of 5 percent 1. What is the synchronous speed of this motor? 2. What is the rotor speed of this motor at rated load? 3. What is the rotor frequency of this motor at rated load? 4. What is the shaft torque of this motor at rated load?

Solution 1. n sync 120 fe 120(60) 1800 P 4 rpm 2. n m (1 sn ) s (1 0.05) 1800 1710 rpm 3. f sf 0.05 60 3Hz r e 4. τ load P ω out m Pout nm 2π 60 10 hp 746 watt / hp 1710 2 π (1/ 60) 41.7 Nm.

Equivalent Circuit The induction motor is similar to the transformer with the exception that its secondary windings are free to rotate As we noticed in the transformer, it is easier if we can combine these two circuits in one circuit but there are some difficulties

Equivalent Circuit When the rotor is locked (or blocked), i.e. s 1, the largest voltage and rotor frequency are induced in the rotor, Why? On the other side, if the rotor rotates at synchronous speed, i.e. s 0, the induced voltage and frequency in the rotor will be equal to zero, Why? E se R R0 Where E R0 is the largest value of the rotor s induced voltage obtained at s 1(loacked rotor)

Equivalent Circuit The same is true for the frequency, i.e. f sf It is known that So, as the frequency of the induced voltage in the rotor changes, the reactance of the rotor circuit also changes Where X r0 is the rotor reactance at the supply frequency (at blocked rotor) r X ωl 2π fl e X ω L 2π f L r r r r r 2π sf L sx r0 e r

Equivalent Circuit Then, we can draw the rotor equivalent circuit as follows Where E R is the induced voltage in the rotor and R R is the rotor resistance

Equivalent Circuit Now we can calculate the rotor current as I R ER ( RR + jx R) ser0 ( R + jsx ) R Dividing both the numerator and denominator by s so nothing changes we get I R Where E R0 is the induced voltage and X R0 is the rotor reactance at blocked rotor condition (s 1) R0 ER0 RR ( + jx R0) s

Equivalent Circuit Now we can have the rotor equivalent circuit

Equivalent Circuit Now as we managed to solve the induced voltage and different frequency problems, we can combine the stator and rotor circuits in one equivalent circuit Where X a X 2 2 2 eff R0 R a R I 2 2 eff R eff E a E a R 1 eff R0 eff I a N N S R

Power losses in Induction machines Copper losses - Copper loss in the stator (P SCL ) I 12 R 1 - Copper loss in the rotor (P RCL ) I 22 R 2 Core loss (P core ) Mechanical power loss due to friction and windage How this power flow in the motor?

Power flow in induction motor

Power relations P 3 VI cosθ 3V I cosθ in L L ph ph PSCL 3 I R 2 1 1 P P ( P + P ) AG in SCL core PRCL 3I R 2 2 2 Pconv PAG PRCL P P ( P + P ) out conv f + w stray τ ind P conv ω m

Equivalent Circuit We can rearrange the equivalent circuit as follows Actual rotor resistance Resistance equivalent to mechanical load

Power relations P 3 VI cosθ 3V I cosθ in L L ph ph PSCL 3 I R 2 1 1 P P ( P + P ) AG in SCL core PRCL 3I R 2 2 2 Pconv PAG PRCL P conv (1 sp ) AG 3I P P ( P + P ) out conv f + w stray 2 2 2 P + R conv (1 s) s τ ind P RCL P 3I R s 2 2 2 P (1 ) RCL s s conv ω m (1 sp ) AG (1 s) ω s P RCL s

Power relations P AG 1 P conv 1-s P : P : P AG RCL conv 1 : s : 1-s P RCL s

Example A 480-V, 60 Hz, 50-hp, three phase induction motor is drawing 60A at 0.85 PF lagging. The stator copper losses are 2 kw, and the rotor copper losses are 700 W. The friction and windage losses are 600 W, the core losses are 1800 W, and the stray losses are negligible. Find the following quantities: 1. The air-gap power P AG. 2. The power converted P conv. 3. The output power P out. 4. The efficiency of the motor.

Solution 1. P 3VI cosθ in L L 3 480 60 0.85 42.4 kw PAG Pin PSCL Pcore 42.4 2 1.8 38.6 kw 2. 3. Pconv PAG PRCL 700 38.6 37.9 kw 1000 P P P out conv F & W 600 37.9 37.3 kw 1000

Solution 37.3 P out 0.746 50 hp 4. Pout η 100% P in 37.3 100 88% 42.4

Example A 460-V, 25-hp, 60 Hz, four-pole, Y-connected induction motor has the following impedances in ohms per phase referred to the stator circuit: R 1 0.641Ω R 2 0.332Ω X 1 1.106 Ω X 2 0.464 Ω X M 26.3 Ω The total rotational losses are 1100 W and are assumed to be constant. The core loss is lumped in with the rotational losses. For a rotor slip of 2.2 percent at the rated voltage and rated frequency, find the motor s 1. Speed 2. Stator current 3. Power factor 4. P conv and P out 5. τ ind and τ load 6. Efficiency

Solution 1. 2. n n sync m 120 fe 120 60 1800 rpm P 4 (1 sn ) (1 0.022) 1800 1760 rpm sync R2 0.332 Z2 + jx 2 + j0.464 s 0.022 15.09 + j0.464 15.1 1.76 Ω 1 1 Z f 1/ jx + 1/ Z j0.038 + 0.0662 1.76 M 2 1 12.94 31.1 Ω 0.0773 31.1

Solution 3. 4. Z Z + Z tot stat f 0.641+ j1.106 + 12.94 31.1 Ω 11.72 + j7.79 14.07 33.6 Ω 460 0 Vφ I 3 1 18.88 33.6 A Ztot 14.07 33.6 PF cos 33.6 0.833 lagging P 3VI cosθ 3 460 18.88 0.833 12530 W in L L PSCL 3I R 3(18.88) 0.641 685 W 2 2 1 1 PAG Pin PSCL 12530 685 11845 W

Solution P conv (1 sp ) (1 0.022)(11845) 11585 W AG 5. 6. Pout Pconv PF & W 11585 1100 10485 W 10485 14.1 hp 746 PAG 11845 τ ind 62.8 N.m ω 2 1800 sync π 60 Pout 10485 τ load 56.9 N.m ω 2 1760 m π 60 Pout 10485 η 100% 100 83.7% P 12530 in

Torque, power and Thevenin s Theorem Thevenin s theorem can be used to transform the network to the left of points a and b into an equivalent voltage source V TH in series with equivalent impedance R TH +jx TH

Torque, power and Thevenin s Theorem jx M VTH Vφ R + jx ( + X ) 1 1 R + jx ( R + jx ) // jx TH TH 1 1 M M V V TH φ X M R + ( X + X ) 2 2 1 1 M

Torque, power and Thevenin s Theorem Since X M >>X 1 and X M >>R 1 X M VTH Vφ X 1 + X M Because X M >>X 1 and X M +X 1 >>R 1 X X X M RTH R1 X 1 + X M TH 1 2

Torque, power and Thevenin s Theorem I 2 V Z TH T V TH 2 R2 RTH + + XTH + X2 s ( ) Then the power converted to mechanical (P conv ) P conv 3I R 2 2 2 (1 s) s And the internal mechanical torque (T conv ) τ ind P conv ω m P conv (1 s) ω s 2 R2 3I2 s ω s P 2 ω AG s

Torque, power and Thevenin s Theorem τ ind 3 V R TH 2 ω 2 s s R2 2 RTH + + ( XTH + X2) s 2 τ ind 1 ω s 3V 2 2 TH 2 R2 RTH + + XTH + X2 s R s ( ) 2

Torque-speed characteristics Typical torque-speed characteristics of induction motor

Comments 1. The induced torque is zero at synchronous speed. Discussed earlier. 2. The curve is nearly linear between no-load and full load. In this range, the rotor resistance is much greater than the reactance, so the rotor current, torque increase linearly with the slip. 3. There is a maximum possible torque that can t be exceeded. This torque is called pullout torque and is 2 to 3 times the rated full-load torque.

Comments 4. The starting torque of the motor is slightly higher than its full-load torque, so the motor will start carrying any load it can supply at full load. 5. The torque of the motor for a given slip varies as the square of the applied voltage. 6. If the rotor is driven faster than synchronous speed it will run as a generator, converting mechanical power to electric power.

Complete Speed-torque c/c

Maximum torque Maximum torque occurs when the power transferred to R 2 /s is maximum. This condition occurs when R 2 /s equals the magnitude of the impedance R TH + j (X TH + X 2 ) R s T 2 max R + ( X + X ) 2 2 TH TH 2 s T max R R + ( X + X ) 2 2 2 TH TH 2

Maximum torque The corresponding maximum torque of an induction motor equals τ max 2 1 3V TH 2 ω R + R + ( X + X ) 2 2 s TH TH TH 2 The slip at maximum torque is directly proportional to the rotor resistance R 2 The maximum torque is independent of R 2

Maximum torque Rotor resistance can be increased by inserting external resistance in the rotor of a wound-rotor induction motor. The value of the maximum torque remains unaffected but the speed at which it occurs can be controlled.

Maximum torque Effect of rotor resistance on torque-speed characteristic

Example A two-pole, 50-Hz induction motor supplies 15kW to a load at a speed of 2950 rpm. 1. What is the motor s slip? 2. What is the induced torque in the motor in N.m under these conditions? 3. What will be the operating speed of the motor if its torque is doubled? 4. How much power will be supplied by the motor when the torque is doubled?

Solution 1. 2. 120 fe 120 50 nsync 3000 rpm P 2 nsync nm 3000 2950 s 0.0167 or 1.67% n 3000 no P sync f + W given assume P P and τ τ τ ind conv load ind load 3 Pconv 15 10 48.6 N.m ω 2π m 2950 60

Solution 3. In the low-slip region, the torque-speed curve is linear and the induced torque is direct proportional to slip. So, if the torque is doubled the new slip will be 3.33% and the motor speed will be n m (1 sn ) (1 0.0333) 3000 2900 rpm sync 4. P τ ω conv ind m 2π (2 48.6) (2900 ) 29.5 kw 60

Example A 460-V, 25-hp, 60-Hz, four-pole, Y-connected woundrotor induction motor has the following impedances in ohms per phase referred to the stator circuit R 1 0.641Ω R 2 0.332Ω X 1 1.106 Ω X 2 0.464 Ω X M 26.3 Ω 1. What is the maximum torque of this motor? At what speed and slip does it occur? 2. What is the starting torque of this motor? 3. If the rotor resistance is doubled, what is the speed at which the maximum torque now occur? What is the new starting torque of the motor? 4. Calculate and plot the T-s c/c for both cases.

Solution V TH V φ X M R + ( X + X ) 2 2 1 1 M 460 26.3 3 255.2 V 2 2 (0.641) + (1.106 + 26.3) X M RTH R1 X 1 + X M XTH 2 26.3 (0.641) 0.590Ω 1.106 + 26.3 X1 1.106Ω 2

Solution 1. s T max R R + ( X + X ) 2 2 2 TH TH 2 0.332 2 2 (0.590) + (1.106 + 0.464) 0.198 The corresponding speed is n m (1 sn ) (1 0.198) 1800 1444 rpm sync

Solution The torque at this speed is τ max 2 1 3V TH 2 ω R + R + ( X + X ) 2 2 s TH TH TH 2 2 3 (255.2) 2π + + + 60 229 N.m 2 2 2 (1800 )[0.590 (0.590) (1.106 0.464) ]

Solution 2. The starting torque can be found from the torque eqn. by substituting s 1 2 R2 3V TH 1 s τstart τind s 1 2 ωs R2 2 RTH + + ( XTH + X2) s 3V 2 TH 2 2 2 s ( RTH + R2) + XTH + X2 ω [ ( )] 2 3 (255.2) (0.332) 2π + + + s 1 2 2 1800 [(0.590 0.332) (1.106 0.464) ] 60 104 N.m R

Solution 3. If the rotor resistance is doubled, then the slip at maximum torque doubles too s T max R 2 2 2 RTH + ( XTH + X2) The corresponding speed is 0.396 n m (1 sn ) (1 0.396) 1800 1087 rpm sync The maximum torque is still τ max 229 N.m

Solution The starting torque is now τ start 2 3 (255.2) (0.664) 2π + + + 2 2 1800 [(0.590 0.664) (1.106 0.464) ] 60 170 N.m

Determination of motor parameters Due to the similarity between the induction motor equivalent circuit and the transformer equivalent circuit, same tests are used to determine the values of the motor parameters. - DC test: determine the stator resistance R 1 - No-load test: determine the rotational losses and magnetization current (similar to no-load test in Transformers). - Locked-rotor test: determine the rotor and stator impedances (similar to short-circuit test in Transformers).

DC test - The purpose of the DC test is to determine R 1. A variable DC voltage source is connected between two stator terminals. - The DC source is adjusted to provide approximately rated stator current, and the resistance between the two stator leads is determined from the voltmeter and ammeter readings.

DC test - then R DC - If the stator is Y-connected, the per phase stator resistance is R R DC 1 2 - If the stator is delta-connected, the per phase stator resistance is 3 R R 1 V I DC DC 2 DC

No-load test 1. The motor is allowed to spin freely 2. The only load on the motor is the friction and windage losses, so all P conv is consumed by mechanical losses 3. The slip is very small

No-load test 4. At this small slip R (1 s) R (1 s) R & s s 2 2 2 2 The equivalent circuit reduces to X

No-load test 5. Combining R c & R F+W we get

No-load test 6. At the no-load conditions, the input power measured by meters must equal the losses in the motor. 7. The P RCL is negligible because I 2 is extremely small because R 2 (1-s)/s is very large. 8. The input power equals Where P P + P + P in SCL core F & W 3I R + P 2 1 1 rot P P + P rot core F & W

No-load test 9. The equivalent input impedance is thus approximately Vφ Zeq X1 + X I 1, nl M If X 1 can be found, in some other fashion, the magnetizing impedance X M will be known

Blocked-rotor test In this test, the rotor is locked or blocked so that it cannot move, a voltage is applied to the motor, and the resulting voltage, current and power are measured.

Blocked-rotor test The AC voltage applied to the stator is adjusted so that the current flow is approximately full-load value. The locked-rotor power factor can be found as PF cosθ Pin 3VI The magnitude of the total impedance l l Z LR V I φ

Blocked-rotor test Z R + jx ' LR LR LR Z cosθ + LR jz LR sinθ R R + R LR 1 2 ' ' ' LR 1+ 2 X X X Where X 1 and X 2 are the stator and rotor reactances at the test frequency respectively R R R 2 LR 1 f rated ' XLR XLR X1+ X2 ftest

Blocked-rotor test X 1 and X 2 as function of X LR Rotor Design X 1 X 2 Wound rotor 0.5 X LR 0.5 X LR Design A 0.5 X LR 0.5 X LR Design B 0.4 X LR 0.6 X LR Design C 0.3 X LR 0.7 X LR Design D 0.5 X LR 0.5 X LR

Midterm Exam No.2

Example The following test data were taken on a 7.5-hp, four-pole, 208-V, 60- Hz, design A, Y-connected IM having a rated current of 28 A. DC Test: V DC 13.6 V No-load Test: V l 208 V I 8.17 A Locked-rotor Test: V l 25 V I 27.9 A I DC 28.0 A f 60 Hz P in 420 W f 15 Hz P in 920 W (a) Sketch the per-phase equivalent circuit of this motor. (b) Find the slip at pull-out torque, and find the value of the pull-out torque.