Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large flow capacity V 4 V 4A C: 0.07 (Standard)/C: 0.07 (Large flow capacity) Flow characteristics C[dm /(s bar)] b Cv 0.07 0. 0.008 0.07 0.070 0.0 Variations Series Standard Large flow capacity V4 V4 V4A V4A Type of actuation N.C. N.O. N.C. N.O. Operating pressure range (MPa) Power consumption (W) With power Standard saving circuit 0. 0. 0. 0. 97
Port Solenoid Valve/Direct Operated Series V00 Rubber Seal Specifications Fluid Air Ambient and fluid temperature ( C) 0 to 0 (No freezing) Note ) Response time (DC) (ms) ON: or less OFF: 4 or less Max. operating frequency (Hz) 0 Manual override Non-locking push, Locking slotted Lubrication Not required Mounting position Unrestricted Impact/Vibration resistance (m/s Note ) ) 0/0 Enclosure Dust proof Note ) Based on dynamic performance test JIS B874-98 (standard type: at coil temperature of 0 C, with rated voltage, without surge voltage suppressor) Note ) Impact resistance: No malfunction resulted in an impact test using a drop impact tester. The test was performed one time each in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. (Value in the initial stage) Vibration resistance: No malfunction resulted in 4 to 000 Hz, a one-sweep test performed in the axial and right angle directions of the main valve and armature for both energized and de-energized states. (Value in the initial stage) Solenoid Specifications Symbol V4(A) V4(A) Series V4/V4 V4A/V4A Electrical entry Grommet (G)/(H), L plug connector(l) M plug connector (M) rated voltage (V) DC 4,,,, AC 0 /0 Hz 00, 0, 00, 0 Allowable voltage fluctuation 0 to 0% Power consumption Standard: 0. (with light: 0.4) (W) DC With power saving circuit 0. W (with light:.) 00 V 0.78 (with light: 0.8) 0 V 0.8 (with light: 0.89) Apparent power (VA) AC [ V] [0.94 (with light: 0.97)] 00 V.8 (with light:.) 0 V.0 (with light:.4) [0 V] [.4 (with light:.4)] Surge voltage suppressor Indicator light Refer to page 97. LED Can be used for 0 VAC and VAC, 0 VAC and 0 VAC in common. For VAC and 0 VAC, the allowable voltage fluctuation will be % to % of the coil rated voltage. The voltage drop will occur due to the internal circuit of S, Z and T types (with energy saving circuits). Allowable voltage fluctuations should be within the range below. S and Z types 4 VDC: 7% to +0% VDC: 4% to +0% T type 4 VDC: 8% to +0% VDC: % to +0% 98
Port Solenoid Valve Series V00 Specifications Valve model V4 V4A V4 Note ) V4A Note ) Valve model V4 V4A V4 Note ) V4A Note ) Construction V4(A) Type of actuation N.C. Standard N.C. Large flow capacity N.O. Standard N.O. Large flow capacity u t o e Model C[dm /(s bar)] 0.07 0.07 0.04 0.099 Operating pressure range (MPa) V4(A) b 0. 0.07 0. 0. Vacuum specification (MPa) Port size Port Port Port, Port 00 kpa to 0. 00 kpa to 0. 00 kpa to 0 00 kpa to 0 00 kpa to 0 00 kpa to 0 00 kpa to 0. 00 kpa to 0. Cv 0.008 0.0 0.0 0.04 Note ) For both V4 and V4A, pressure from port and exhaust from port. Note ) The values shown in ( ) are for values with sub-plate. Flow characteristics C[dm /(s bar)] 0.04 0.099 0.07 0.07 No. 4 7 8 9 Grommet V 4:(7) V 4A:(0) b 0. 0. 0. 0.07 Component Parts Description Body Cover Push rod Armature assembly Poppet Return spring Poppet spring assembly Manual override Weight (g) Note ) L plug connector M plug connector Plug connector V 4:() V 4A:(9) Cv 0.0 0.04 0.008 0.0 Material Resin Stainless steel Resin Stainless steel, Resin FKM Stainless steel Stainless steel Resin VV0 VV00 V00 -V F VS Replacement Parts No. 0 Description Gasket assembly Sub-plate Part no. V00--A V00-74- Material FKM, Steel Aluminum die-cast Note Gasket, screws How to Order Connector Assembly q!0 (P)(A) (R) w! y i r : For 00 VAC: SY00 0 4A SY00 0 A For 00 VAC: For other voltages of AC: SY00 0 A SY00 0 A Without : (with connector and sockets) SY00 0 A Lead wire length Nil 00 mm 00 mm 0 000 mm 00 mm 0 000 mm 00 mm 0 000 mm 0 000 mm 99
Series V00 Note) How to Order Note) DC specifications only Standard type Base mounted V 4 M port Port size Nil: Without sub-plate M: With sub-plate Sub-plate style, For manifold type S4 Type of actuation Normally closed Normally open (With gasket and screws) specification Nil 0. W 0. W (with power saving circuit) T (4 VDC, VDC only) All the types with power saving circuit are with light and surge voltage suppressor Z. Manual override Nil: Non-locking push V S R Rated voltage CE-compliant 4 VDC VDC VDC VDC VDC B: Locking slotted For AC ( 0/0 Hz) 4 00 VAC 00 VAC 0 VAC [ VAC] 0 VAC [0 VAC] CE-compliant Electrical entry 4 V, V, V, V, VDC/00 V, 0 V, 00 V, 0 VAC Grommet L plug connector M plug connector G: 00 mm H: 00 mm L: With 00 mm M: With 00 mm +- MN: Without +- Light/Surge voltage suppressor Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar) With light/surge voltage suppressor (Non-polar) Only Z is available for the types with power saving circuit., AC, AC + LN: Without LO: Without connector MO: Without connector - LN and MN types are with sockets. Refer to page 9 for the different lengths of L and M plug connectors. Refer to page 97 for the connector assembly with a dustproof cover for L and M plug connectors. 90
Port Solenoid Valve Series V00 How to Order Large flow type Base mounted port Sub-plate style, For manifold type S4 Type of actuation V 4 A M Normally closed Normally open Large flow capacity Port size Nil: Without sub-plate (With gasket and screws) Manual override Nil: Non-locking push M: With sub-plate VV0 VV00 V00 -V F VS Rated voltage V S R 4 VDC VDC VDC VDC VDC B: Locking slotted Electrical entry 4 V, V, V, V, VDC Grommet L plug connector M plug connector G: 00 mm H: 00 mm L: With 00 mm M: With 00 mm +- MN: Without +- Light/Surge voltage suppressor Nil R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor LN: Without LO: Without connector MO: Without connector LN and MN types are with sockets. Refer to page 9 for the different lengths of L and M plug connectors. Refer to page 97 for the connector assembly with a dustproof cover for L and M plug connectors. 9
Series V00 Base Mounted (With sub-plate) Grommet (G), (H): V 4(A)- -M G H (Light/Surge voltage suppressor). Note) [ ]: AC : values for the large flow type (A) 0 L plug connector (L): V 4(A)- L -M M plug connector (M): V 4(A)- M -M. 9. [4.] 4. 40.7 [4.9] 4.9 0.9 [.]..9. x ø. (Mounting hole) G: Approx. 00 H: Approx. 00 (Lead wire length) 8. [.].4.7.4 7.7.7 0.8 []. 9. (Piping port) 9 (Light/Surge voltage suppressor) (Light/Surge voltage suppressor) Approx. 00 (Lead wire length) Approx. 00 (Lead wire length) Other dimensions are same as the grommet type. Other dimensions are same as the grommet type. 9
Port Solenoid Valve Series V00 Manifold Specifications Flow Characteristics Manifold Type VV00-S4 V4 V4A V4 V4A Port size Port,, Note) Values when mounted on the manifold base ( stations). Manifold Specifications Model Manifold P (SUP)/R (EXH) style Valve stations Output port porting specifications Port size C[dm /(s bar)] 0.0 0.070 0.00 0.08 How to Order Valve Manifold Assembly (Example) Ordering example Valve (N.C.) V4-GZ Location Direction Port,, Note ) V4(A) and V4(A) cannot be mounted to the same manifold. Note ) For V4(A), pressure from port and exhaust from port. b 0. 0.0 0. 0. Flow characteristics Cv 0.007 0.0 0.0 0.00 Type S4 Single base style/b mount Common SUP/Common EXH to 0 stations Base Side C[dm /(s bar)] 0.00 0.08 0.0 0.070 b 0. 0. 0. 0.0 Cv 0.0 0.00 0.007 0.0 VV0 VV00 V00 -V F VS Stations 4 Manifold base ( stations) VV00-S4-0-M Blanking plate assembly V00-77-A VV00-S4-0-M V00-77-A V4-GZ set (Type S4, station manifold base part no.) set (Blanking plate assembly part no.) 4 sets (Valve) The asterisk ( ) is used when referring to assembly. Enter the asterisk at the beginning of individual component part numbers. Beneath the manifold base part number, enter the valve and option part numbers to be mounted. 9
Series V00 Common SUP/Common EXH Type S4 Port Port Port How to Order VV00 S4 0 M Stations port size 0 stations M 0 0 stations Note) V4(A) and V4(A) cannot be mounted to the same manifold. Applicable solenoid valve Note) V4- V4A- V4- V4A- Applicable blanking plate assembly V00-77-A Gasket Assembly Part No. V00--A Round head combination screw Blanking Plate Assembly Part No. V00-77-A Place the notch mark on a blanking plate to the port side when assembling. Round head combination screw Notch mark Blanking plate Gasket Gasket Applicable base Sub-plate Type VV00-S4 manifold base Applicable base Sub-plate Type VV00-S4 manifold base Caution Mounting screw tightening torques M: 0. N m 94
Port Solenoid Valve Series V00 Type S4 Manifold: Side Ported/VV00-S4- Stations -M Note) [ ]: AC : values for the large flow type (A) Grommet (G), (H) (Pitch) P=0.. VV0 7 [4] 0.9.. 0 VV00 V00 x ø. (Mounting hole) L L (Indicator light and surge voltage suppressor) G: Approx. 00 H: Approx. 00 (Lead wire length).4 [4.] 4. (Port, ) -V F (n station) ( station) VS L plug connector (L) M plug connector (M). [4.7] 4.7 8. [4.] 4. 7.7 (Port ) (Pitch) P=0. 0. 4. [44.] 44. 7. Other dimensions are same as the grommet type. Other dimensions are same as the grommet type. Station L L stations. 7. 44 8 4 4. 48. 9 7. 9. 7 8 80 8 9. 90. 9 07 0 0 7.. 8 8.. 49 4 4 9.. 70 4 80. 74. 7 9 8 8 0. 9. 9 0 0 stations.. 9
Series V00 Specific Product Precautions Be sure to read before handling. Refer to front matter for Safety Instructions and pages to 8 for /4/ Port Solenoid Valve Precautions. Warning Manual Override Operation Since connected equipment will be actuated when the manual override is operated, first confirm that conditions are safe. Non-locking push type [Standard type] Press in the direction of the arrow Caution How to Use of Plug Connector. Attaching and detaching connectors To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever's pawl is pushed into the groove and locks. To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. Core wire crimping area Socket Cover Groove Pin Connector Crimping area Core wire Lead wire Locking slotted type [B type] Turn in the direction of arrow. Cover Groove Pin. Crimping of s and sockets Strip. to.7 mm at the end of the s, insert the ends of the core wires evenly into the sockets, and then crimp with a crimping tool. When this is done, take care that the coverings of the s do not enter the core wire crimping area. Use special tool when crimping. (Consult with SMC for the crimping tool.) -+ Hook Caution When operating with a screw driver, turn it gently using a watchmakers screw driver. [Torque: less than 0.Nm] Lever DC polarity indication Socket Part no. DXT70-7- Lead wire 0. to 0. mm Max. cover diameter: ø.7 mm Caution How to Use a Plug Connector. Attaching and detaching s with sockets Attaching Insert the sockets into the square holes of the connector ( +, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the s. Detaching To detach a socket from a connector, pull out the while pressing the socket's hook with a stick having a thin tip (about mm). If the socket will be used again, first spread the hook outward. Socket Plug Connector Lead Wire Length How to Order Connector Assembly : For 00 VAC: For 00 VAC: For other voltages of AC: Hook Without : (with connector and sockets) SY00 0 4A SY00 0 A SY00 0 A SY00 0 A SY00 0 A Connector Lead wire Standard length is 00 mm, but the following length is also available. How to Order To order a valve with length of other than 00 mm, indicate part numbers of the valve without connector and the required connector assembly separately. <Example> Lead wire length 000 mm V4-LO SY00-0-4A-0 For AC V4A-LO SY00-0-A-0 Lead wire length Nil 0 0 0 0 00 mm 00 mm 000 mm 00 mm 000 mm 00 mm 000 mm 000 mm Hook Insulation 9
Series V00 Specific Product Precautions Be sure to read before handling. Refer to front matter for Safety Instructions and pages to 8 for /4/ Port Solenoid Valve Precautions. Surge Voltage Suppressor <> Grommet, L and M Plug Connector Standard type (with polarity) With surge voltage suppressor ( S) Red (+) Black ( ) Red (+) Black ( ) (+, ) (,+) Varistor (+, ) Varistor LED Polarity protection diode Polarity protection diode (,+) LED Please connect correctly the s to + (positive) and (negative) indications on the connector. voltages other than, 4 VDC, incorrect wiring will cause damage to the surge voltage suppressor circuit since a diode to prevent reverse current is not provided. (Wrong polarity will cause trouble.) Solenoids, whose s have been pre-wired: positive side red and negative side black. With power saving circuit Power consumption is reduced by approximately 7% compared with the standard product by eliminating the need for electrical current for holding. (Effective after more than ms energized and 4 VDC rated voltage applied.) Operating Principle The electrical circuit as shown above, allows reduced holding current consumption and measures power saving. Refer to the electric waveform on the right. Please be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for the power saving circuit. (~) Varistor With light/surge voltage suppressor ( Z) Non-polar type With surge voltage suppressor ( R) With light/surge voltage suppressor ( U) Electric circuit (with power saving circuit) For Single Solenoid Red (+) Black ( ) Diode LED Timer circuit Polarity protection diode Not available in the VDC specifications. (~) Caution In the case of varistor surge voltage suppressor, note the surge voltage to be suppressed at controller side as there will be a residual voltage according to the protective element and rated voltage. Moreover, the residual voltage of the diode is approximately V. : Starting current, : Holding current <Electric waveform in power saving, in the case of V 4T> Applied voltage 4 V 0 V 0.4 W 0. W <For AC> Grommet, L and M Plug Connector With light ( Z) 0 W ms Standard With power saving circuit Connector Assembly with Cover Connector assembly with protective cover enhances dust protection Effective in preventing possible short circuit problems due to contaminants in contact with connector section. Cover material is chloroprene rubber which has excellent weatherability and electric insulation properties. However, be careful not to allow contact with cutting oil, etc. Round cord provides neat appearance. How to Order SY00-8 - A - L Lead wire length (L) Nil 0 0 0 0 00 mm 00 mm 000 mm 00 mm 000 mm 00 mm 000 mm 000 mm Connector Assembly with Cover/Dimensions (8) (ø4.) Gray Red Black (4.) How to Order Indicate part number of connector assembly with cover in addition to the solenoid valve part number without connector of the plug connector. <Example > Lead wire length: 000 mm V4-LOZ-M SY00-8-A-0 <Example > Lead wire length: 00 mm (Standard) V4-LPZ-M Symbol for a connector assembly with cover (40) (0) Connector Connector (.9) (8) No need to indicate the part number for a connector assembly with cover in this case. 97 VV0 VV00 V00 -V F VS