siemens.com/mobility Trainguard LEU S21 Central trackside equipment component



Similar documents
siemens.com/mobility/mobility Trainguard Imu 100 inductive transmission system Efficient and reliable rail operations

S 700 K point machine. Setting points reliably.

Trainguard Full Interoperability for European Railways

siemens.com/mobility Trainguard Full interoperability for rail traffic

Trainguard Sirius CBTC

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Product Information Fire alarm panel 8000 C

Permissible ambient temperature Operation Storage, transport

Rack mounted telephone- and leased line modem for industrial applications

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Digital input modules

Telephone- and leased line modem for industrial applications TD-36

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Single Channel Loop Detector

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

Siemens AG Mobility Division Nonnendammallee Berlin Germany

FAdC i FRAUSCHER Advanced Counter i

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SAFETY MANUAL SIL RELAY MODULE

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

OZW30. Central Unit SYNERGYR

Modular I/O System Analog and Digital Interface Modules

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems

European Rail Traffic Management System (ERTMS) Complete Solutions for ETCS and GSM-R

Power network telecommunication

ST900 intersection controller. Traffic Solutions

FIREDEX Conventional Fire Panels

What ensures easy and fast wiring?

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Number 1 in efficiency

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Voltage Regulator SPAU 341 C. Product Guide

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

F2400 FOM II Series Fiber Optic Modem Technical Manual

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

TX OPEN RS232/485 module

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

GAE953 Electrical Alarm Unit 19" with Indicator

CTCS Chinese Train Control System

Features, Benefits, and Operation

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Thameslink Desiro City & Signalling Press Trip April 20 to 21, 2015 Evolution in Motion. Siemens Mobility Division

Supplement to the Operating Instructions for SIMOREG DC-MASTER Series 6RA70. for Software Release 3.2. Version 13 Order no.

RRV934. Multi-controller. Synco living

Technical Data. Dimensions

M-Bus-Logger Data Logger

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Simis W electronic interlocking. Safe and economical.

TMS TANK MANAGEMENT SYSTEM

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Safety Relays ESM/ESM-F

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

PCS0100en Persy Control Services B.V. Netherlands

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

SAFETY MANUAL SIL Switch Amplifier

Repeaters and Mimics Data Sheet

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Complementary Tests: the key of the successful ERTMS deployment in Spain.

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

instabus KNX / EIB System System E F G H

On-line Machine Condition Monitoring [The CMS System]

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Intersection Preassembled 19-inch Rack

C9 HD Video Conference Terminal

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

DC Electronic Loads 8500 series

Non-Stop Manufacturing Excellence. Automotive. Answers for industry.

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS


Danfoss Link Mobile Phone Butler

Terminal and Dimension

PLICSMOBILE: Measurement data via the mobile network

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PD 100A. Printing data system

Job Aid Pre-Installation Information S8500 Media Server

Power Feeding Equipment for Optical Submarine Cable Systems

Frequency Converter Fv

New XUY roller sensors

The solution for Europe: Type 2 charging socket with or without shutter

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Catalog. Arc Guard System TM TVOC-2

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Transcription:

siemens.com/mobility Central trackside equipment component

cross-border safety with ETCS Level 1 Ensuring mobility is one of the big challenges in our society. To ensure our mobility in future, we need networked transportation and information systems. And we will only meet these mobility requirements through efficient coordination and perfect meshing of all modes of transportation. This is why Siemens with its Complete mobility approach is offering integrated transportation and logistics solutions for safe, cost-effective and environmentfriendly passenger and freight services. Trainguard is the Siemens solution for the standardized European ETCS automatic train control system which is gradually replacing the different national train protection and train control systems. The (lineside elec-tronic unit) is the link between the existing fixed trackside signals and the in-track ETCS components Trainguard Eurobalise S21 and Trainguard Euroloop S21 F. In more than 1,000 applications in various countries, the has demonstrated its extreme reliability. Principle of operation A transmission point equipped for ETCS normally comprises a fixed-data balise and a variable-data balise. The telegrams are transmitted intermittently using Eurobalises, but continuous transmission by means of Euroloops is also possible at certain locations. The aspect shown by a signal is extracted by the Trainguard LEU S21, the associated telegram selected and a serial data stream transmitted continuously to the variable-data balise(s) or Euroloop modem via a stand-ardized interface. When a vehicle equipped with ETCS passes, the ETCS telegram is sent and evaluated by the EVC (European vital computer). All the configuration data, signal codes and telegrams belonging to a signal are stored in the. When the LEU detects an invalid signal aspect, a fault telegram is output. Programming and diagnostics The core element for program-ming and diagnostics is a handheld computer. The data created during configuration is transferred via the handheld computer and safely stored in the memory. Moreover, the displays on the as well as the handheld computer offer convenient support for diagnostics. Installation The entire wiring and all connectors for external connections are integrated into a mounting rack and accessible from the front. The is generally accommodated in the signal cabinet of the signal being equipped. It is connected directly to the cable feeder from the interlocking to the signal or the lamp circuit.

1 2 Benefits and features of the Compact design Installation is possible in practically all off-the-shelf cabinets which are accessible from the front. This enables easy component replacement and guarantees low modification costs. Safe current pick-off A low-impedance transformer can be looped into existing signal circuits without affecting the control distance. Lamp tapping using a current transformer is in conformance with SIL 4. Absence of interaction Easily proven thanks to the properties of the isolating current transformer. The has already been approved for various signaling systems. Cascadability A modular with signal interface supplies the signal aspect to up to three simplified cascaded LEUs. Hence, a maximum of eight outputs is available for balises / loops. Patented programming procedure The patented programming procedure ensures data transmission between the handheld computer and the Trainguard LEU S21 in conformance with SIL 4. Three-level diagnostic concept General diagnostics without tools is possible at two levels: LEDs (operating state) 7-segment display (cause of fault) Detailed diagnostics using a handheld computer allows data recording in the case of temporary faults. High level of availability The disables outputs for Eurobalises/Euroloops in the event of faults and enables them as soon as the fault has been remedied. Monitoring functions ensure smooth operation, thus increasing availability of trackside equipment considerably and minimizing the number of maintenance staff deployed. 3 Maintenance-free operation The is maintenancefree no periodic checking is required. 7 European vital computer (EVC, on-board computer) 8 DMI (driver-maschine interface) 9 Odometer pulse generator 10 Radar 7 6 8 1 2 S21 fixed-data balise 3 S21 variable-data balise 4 Trainguard Euroloop S21 F (optional) 5 Balise/loop antenna 6 Receive-and-forward unit 9 10 5 4 2 3 1

4 Technical data Current inputs Number of inputs Input range Flashing detectors up to 16 inputs configurable 30 ma to 4 A (15 to 440 Hz) up to four inputs configurable Voltage inputs Number of inputs Input range Flashing detectors up to eight inputs configurable AC 0 Vrms bis 181 Vrms (15 Hz bis 66 Hz); DC 0 bis 181 V 2 inputs configurable Power supply Input ranges AC 88 Vrms bis 264 Vrms (15 Hz bis 90 Hz); DC 34 V bis 177 V Telegram generator/outputs Outputs Extension Interface signal 'C' Interface signal 'CL' Number of telegrams Telegram length 2 S21 variable-data balises 2 Trainguard Euroloops of type S21 F or combination up to eight outputs using cascaded as per UNISIG SUBSET-036 FFFIS for Trainguard Eurobalise as per UNISIG SUBSET-044 FFFIS for Trainguard Euroloop 1,023 (2 x) telegrams per output 341 or 1,023 (2x) bits (selectable)

4 Technical data Reliability (MTBF as per SN 29500) Dimensions (L x W x H) Weight > 31.7 years 185 x 190 x 286 mm 3.8 kg Ambient temperature 40 C to +70 C IP rating IP20 (installation in housing with rating of at least IP 54 1 2 for bus connection with handheld computer 3 with ELM S21 F Euroloop modem in signal cabinet 4 for signal connection

Trainguard is a registered trademark of Siemens AG. Siemens AG Mobility Division Nonnendammallee 101 13629 Berlin Germany Siemens AG 2014 Printed in Germany PPG177 PA09140.5 Dispo 01000 Order No.: A19100-V100-B875-V4-7600 The information in this document contains general descriptions of the technical options available. The required features should therefore be specified in each individual case at the time of closing the contract. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action and integrate each component into a holistic, state-of-the-art security concept. Third-party products that may be in use should also be considered. www.siemens.com