Introducing Signa HDxt with Optima Edition 23.0

Similar documents
Musculoskeletal MRI Technical Considerations

GE Medical Systems Training in Partnership. Module 12: Spin Echo

SITE IMAGING MANUAL ACRIN 6698

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

MRI SEQUENCES. 1 Gradient Echo Sequence

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact:

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

Purchasing a cardiac CT scanner: What the radiologist needs to know

The smart approach to digital MRI

AI CPT Codes. x x MRI Magnetic resonance (eg, proton) imaging, temporomandibular joint(s)

GE Healthcare. pet/ct for simulation. Precision in motion.

PET/CT-MRI First clinical experience

MRI for Paediatric Surgeons

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Computed Tomography, Head Or Brain; Without Contrast Material, Followed By Contrast Material(S) And Further Sections

Advanced MRI methods in diagnostics of spinal cord pathology

CPT Radiology Codes Requiring Review by AIM Effective 01/01/2016

Voxar 3D TM. A suite of advanced visualization and analysis software tools

Current Industry Neuroimaging Experience in Clinical Trials Jerome Barakos, M.D.

GE Healthcare. Vivid 7 Dimension Cardiovascular Ultrasound System

Configuration and Use of the MR Knee Dot Engine

University Children s Hospital Basel

THE WIDEST WIDE-BORE IN THE INDUSTRY

Etude POPART'MUS MRI Component

RF Coils... They ve Come a Long, Long Way

GE Healthcare. Centricity PACS and PACS-IW with Universal Viewer* Where it all comes together

NEURO MRI PROTOCOLS TABLE OF CONTENTS

32-Channel Head Coil Imaging at 3T

MGH Adult Diffusion Data Scanning Protocols

Magnetic Resonance Quantitative Analysis. MRV MR Flow. Reliable analysis of heart and peripheral arteries in the clinical workflow

Ultrasound. Your versatile performer to depend on. Philips ClearVue ultrasound family for women s health care

Procedure Codes. RadConsult provides real-time decision support for physicians who order high-cost imaging procedures RADIATION THERAPY

AW Server 3 for Universal Viewer

Vivid S6. Cardiovascular ultrasound system. imagination at work. GE Healthcare

CPT * Codes Included in AIM Preauthorization Program for 2013 With Grouper Numbers

CPT CODE PROCEDURE DESCRIPTION. CT Scans CT HEAD/BRAIN W/O CONTRAST CT HEAD/BRAIN W/ CONTRAST CT HEAD/BRAIN W/O & W/ CONTRAST

Overview. Optimizing MRI Protocols. Image Contrast. Morphology & Physiology. User Selectable Parameters. Tissue Parameters

GE Healthcare. Centricity* PACS and PACS-IW with Universal Viewer. Universal Viewer. Where it all comes together.

GE Healthcare. Centricity * PACS with Universal Viewer. Universal Viewer. Where it all comes together.

Imaging of Acute Stroke. Noam Eshkar, M.D New Jersey Neuroscience Institute JFK Medical Center Edison Radiology Group

Case Report: Whole-body Oncologic Imaging with syngo TimCT

3/30/2013. Disclosure. Advanced Neuro MRI: Imaging Techniques and Protocol Optimization. MRI, 35 year ago. MRI Today. Outlines

Breast MRI Quality Control

It takes two to connect the dots in MRI.

In Practice Whole Body MR for Visualizing Metastatic Prostate Cancer

Standardized MRI Protocol for Brain Tumor Clinical Trials. Benjamin M. Ellingson, Ph.D. Assistant Professor of Radiology at UCLA

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

The Dedicated MRI Factbook. Esaote MRI: A world of difference

Diagnostic Imaging Prior Review Code List 3 rd Quarter 2016

Magnetic Resonance Imaging

MRI QA Technologist s Tests

GE Healthcare. Great treasures in small places. BrightSpeed Elite

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

Challenge of FUJIFILM in Medical ICT

Unwarping Echo Planar Images Using CMTK 1 Release 1.2

Three Dimensional Ultrasound Imaging

Image Gallery MAGNETOM Skyra Answers for life.

2016 CPT Radiology, ECHO, and PET Codes Requiring Review Modality Body Part Group # CPT Description Default CPT "1"

How To Grow With An Mri

Oncentra Brachy Comprehensive treatment planning for brachytherapy. Time to focus on what counts

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi

What s new in Trendsetting Applications?

MRI Physics for Radiologists

Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute

ViewPoint 6. Clarify your View

Company profile. Quote from the analyst of. Company Milestone. Feel the Difference. Tel: Fax:

RE: Invitation for Bid (IFB) No. Q14-32 Type of Service: Magnetic Resonance Imaging System, Maintenance Agreement and Mobile MRI Unit. Addendum No.

The New Enhanced Multiframe CT and MR DICOM Objects

GUIDE TO SETTING UP AN MRI RESEARCH PROJECT

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Software Packages The following data analysis software packages will be showcased:

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

How To Improve Your Ct Image Quality

Magnetic Resonance Imaging

Lecture 14. Point Spread Function (PSF)

Image Area. View Point. Medical Imaging. Advanced Imaging Solutions for Diagnosis, Localization, Treatment Planning and Monitoring.

POWERFUL ACCESSIBILITY. A SINGLE WORKSPACE. A MYRIAD OF WORKFLOW BENEFITS. Vue PACS. Radiology

imc FAMOS 6.3 visualization signal analysis data processing test reporting Comprehensive data analysis and documentation imc productive testing

76641 Ultrasound, breast, unilateral, real time with image documentation, including axilla when performed; complete limited

Embedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008

Shorter Scanning Times Through Efficient Software. Annette Tuffs. Article from the customer magazine Medical Solutions, December 2010

StentViz Enhanced Stent Visualization

SAMSUNG ULTRASOUND RS80A

Patient Prep Information

5 Factors Affecting the Signal-to-Noise Ratio

Recommendations for cross-sectional imaging in cancer management, Second edition

I SEE THE FUTURE

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.

Quantitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

Deformable Registration for Image-Guided Radiation Therapy

COST AID ASL post- processing Workshop

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care

THEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI. Douglas C. Noll* and Walter Schneider

Transcription:

Introducing Signa HDxt with Optima Edition 23.0 Signa HDxt gets even better with the Optima Edition 23.0 platform New Express Exam user interface New applications New GEM Flex Suite

Advanced applications designed to enhance your productivity, consistency, and image quality

PROPELLER 3.0 Significantly reduced motion and flow effects Enhanced tissue contrast Motion correction option for difficult patients Available in T2, T2 FLAIR, T1 FLAIR and Diffusion 3T PROPELLER T2 Sagittal acquisition on healthy volunteer

PROPELLER 3.0 Significantly reduced motion effects incl. peristalsis and flow Excellent tissue contrast Same scan time as conventional techniques Free breathing acquisition "I have been using PROPELLER T2 and PROPELLER T2 FLAIR routinely on all brain MRI scans at my facility during the last 4 years. During that time, I have NEVER had to repeat a PROPELLER scan. 1 A. Joseph Borelli, MD. MR at Belfair, Bluffton SC, US 1 Individual results may vary Conventional FSE PROPELLER 3.0 Correction of motion caused by peristaltic activities and fluid motion in ascites patient, at 3T. Courtesy: St Joseph s Hospital, France 1.5T HDxt Axial PROPELLER

PROPELLER 3.0 Inherent insensitivity to motion Uniform image, no Phase/Frequency Improved scan time efficiency over 2D-FSE The use of PROPELLER helped us improve the average image quality and robustness of the shoulder exams, but also resulted in a productivity gain too, not having to repeat any series anymore. Dr. E. Pessis, MD CCN, St Denis, Fr. PROPELLER 3.0, FatSat 8 ch Shoulder PA coil 3min43s acquisition per series 3.5mm slice thickness 0.6mm in-plane resolution

3D Cube 2.0 Scan once, reformat into any plane Reliably visualize even small and subtle lesions Automated, rapid, whole brain volume exam Available as T1, T2, T2 FLAIR and PD 1.5T Cube T2 FLAIR 3D rendering of healthy volunteer

3D Cube 2.0 3D FSE T2 or PD High resolution - delineate fine detail Resolve what was once obscure Scan once, reformat into any plane helps reduce total exam time A five-minute 3D Cube sequence can provide similar information as a 30 minute routine MR protocol. R. Kijowski, MD UW Madison, WI 3.0T Cube, 0.4x0.4x0.6 mm

Ready Brain Fully automated exam Accurate planes and reproducible slice positions for easy follow up exams Consistent image quality Simple and fast, also for non-expert users 1 Automatic localizer, Rx, scan, reformatting, postprocessing and data management Automatic midsagittal plane calculation for 2D/3D Rx and ACPC determination Extreme (>45 deg) rotation correction 1 Compared to conventional MR acquisition Automated Ready Brain (per protocol): Localizers acquired Midsagittal plane detected Scan planes computed All series scanned per protocol Post-processing completed Raw data pushed to PACS & selected series to AW PACS Reading room

1.5T 3D ASL Cerebral blood flow (CBF) map Courtesy of Yokohama Sakae Kyosai Hospital 3D Arterial Spin Labeling 3D whole brain coverage in high res Provides quantitative CBF values High SNR and robust at 3T and 1.5T: - Insensitive to susceptibility & motion - Free of geometrical distortion (typical for EPI) Instantaneous, automated post-processing We currently perform ASL on all patients with suspected or known cerebrovascular disease. The 3D FSE readout permitted the visualization of small structures ( ) In several cases the 3D ASL images have increased our confidence or suggested an unexpected, alternative diagnosis. Greg Zaharchuk, MD, Stanford Radiology, CA

Non-contrast 3D ASL quantitative brain perfusion Full brain coverage free of geometrical distortion (typical for EPI) 3D + FSE for high SNR (vs. 2D EPI) Robust with susceptibility & motion 3D ASL on 1.5T HDxt, 3 x 3 x 4 mm

LAVA Flex Four image contrasts in one breath-hold - rapid Water, fat, in-phase, and out-of-phase - no mis-registration Higher SNR and CNR than standard LAVA Less sensitive to field inhomogeneities LAVA Flex provides 3D T1w imaging with high SNR and CNR, with very homogeneous fat saturation Dr M. Zins, Hopital St Joseph, Paris, France In Phase Out of Phase Fat Water

Enhanced DWI 1 Improved ADC quantification Improved SNR and contrast Reduced scan time smart averaging Improved spatial resolution 3-in-1 mode Respiratory triggering support for free breathing "In our facility, we have found that the high image quality of the IR-prep DWI sequence is applicable for a broad range of oncology studies and treatment monitoring" Dr T. La Folie, HIA Laveran/Ste Anne, France 1 Compared to conventional DWI technique Respiratory Triggered edwi at 3T Courtesy: Keio University, Japan Liver mets 3-in-1, B500, 4 NEX Breath-hold b20 1NEX b500 3NEX b800 3NEX 3-in-1 192 x 224 in 30sec

Frequency Amplitude ASPIR: Adiabatic Spectral Inversion Recovery Homogeneous fat suppression Excellent contrast between soft tissue and fat Uniform inversion of the fat magnetization vector Available with: Cube, SSFSE, 2D FIESTA, Inhance Inflow IR, COSMIC, and VIBRANT Adiabatic IR TI Data Acquisition Amplitude and frequency modulated inversion Insensitive to B1 field non-uniformities SSFSE ChemSat at 3T SSFSE ASPIR at 3T Axial FIESTA ASPIR at 3T Courtesy: St. Joseph, France Images acquired with Discovery MR750, and comparable to expected results from Signa HDxt Coronal FIESTA ASPIR at 3T

MR Touch / MR Elastography Vibration Acquisition Reconstruction Active driver Passive driver Sound Waves Shear waves MRE Scan Wave Image Shear waves generated by external acoustic driver Shear waves transmitted to tissue by passive driver. Motion Synthesis Shear waves captured using phase contrast gradients GRE with modified cyclic motion-encoding gradients Inversion algorithm used to convert wave images into stiffness map External acoustic driver triggered by PSD. MEG gradient synchronized with external acoustic vibrations Soft Elastogram Hard Not available for sale in Japan

Performance of MR Touch in Real Clinical Situations Obesity 10 Ascites BMI = 36 0 20 0 Not available for sale in Japan Courtesy Mayo Clinic

IDEAL Productivity - Multiple contrast from one scan Perfect registration with & without fatsat, no chemical shift Superb fat-water separation All T1, T2, PD contrasts Select the desired output images Parallel imaging Region growing based field maps 2D FSE and 3D GRE implementations Fat Only Water Only In Phase Out of Phase

3D MERGE Patient with suspected Multiple Sclerosis Fast, high resolution axial volumetric scan Water excitation for cartilage imaging Easy reformat in any plane MERGE Knee In our clinical practice, the 3D MERGE technique has been used primarily for spine imaging and this acquisition is now included in our routine protocol for cervical, thoracic and lumbar spinal imaging. Jang-Gyu Cha, MD Soonchunhyang University Hospital, Bucheon, South Korea 3D MERGE, with Water Excitation and Without

Inhance Inflow IR 2.0 Consistent, robust NCE 3D MRA for arteries & veins (Renal, Portal, Carotids etc.) Flexible scan plane with excellent fat, flow and background suppression Fast: scan time < 4 min with respiratory trigger Inhance Inflow IR 1.5T 8 Channel Torso Coil With Inhance Inflow IR 2.0, we have noticed a change in referral patterns, with a larger volume of renal impairment patients and those who refuse IV contrast or cannot hold their breath for 25 s Prof. Wladyslaw Gedroyc @ St. Mary s Hospital, UK

Quick Step Simplified Workflow Courtesy Addenbrookes Hospital, UK Discovery MR450 1.5T Discovery MR450 1.5T Discovery MR750 3.0T Images comparable to that which could be expected with Signa HDxt 1.5T and 3.0T

Signal Intensity Signal Intensity 3D Heart, CINE-IR & FGRE-TC imaging 120 120 100 80 Blood Pool Myocardium Amyloid 100 80 Blood Pool Myocardium 60 60 40 20 9 Minutes -100 0 100 200 300 400 500 600 700 TI (ms) 40 20 Normal 9 Minutes 0-100 0 100 200 300 400 500 600 700 800 TI (ms) 3D HEART Streamlined prescription and hi-res, whole heart morphology at 3T CINE-IR Quick assessment of optimal TI time for MDE myocardial viability studies and tissue characterization through T1 curve FGRE Time Course High temporal and spatial resolution for time course studies

ReportCard Cardiac Visualization & Reporting Comprehensive CMR post-processing capability with automatic segmentation Integrate reporting with images, data and impression for effective information transfer to referring physician LV function analysis Infarct sizing LV function & auto segmentation Time-course analysis Flow Analysis Infarct sizing T2* mapping PFO analysis Research Database Macro reporting Time course analysis Flow analysis T2* mapping analysis

Cardiac VX Simple & intuitive workflow Guided UI Reduce cardiac analysis time Faster & more accurate new LV segmentation algorithm Quick report generation with macros, customizable report templates & normal values Easy comparison with multi-study viewing mode Automatic image series filter Optimized loading & post-processing speed New 2 Clicks LV segmentation algorithm Fast EF Simpson s Rule New Flow Regurgitation Fraction calculation MDE, Time Course, PFO, StarMap analysis Function Analysis Flow Analysis MDE, Time Course, StarMap Not available for sale in Japan

Flow Analysis 4 on Console 1 Quick Flow analysis during exam Helps reduce patient recall Enables fast decision making ReportCard Flow Analysis 4 available on console Full Functionality with - Automated segmentation - Displays flow rate & other parameters - Macro impression editor & report generation 1 Discovery MR70/450/750w and Optima MR450w

GEM Flex Suite GEM Flex Suite: Three high-density 16 channel arrays, knee support and fixation, coil fixation pad Variable element density helps ensure optimum imaging for patient size Light & flexible to accommodate a wide range of shapes Durable outer shell for simple cleaning and maintenance Elbow at 1.5T Axial and Coronal PD FSE Fat saturation 2.5mm 320x192 3:30 min 24 GE Healthcare Optima MR450w with GEM by NeoCoil; not compatible with 3.0T Not available for sale in Japan

MR750/450/450w High Density Cardiac Imaging Now compatible with Signa HDxt 32 Element Cardiac Coil High Density Design for Fast Imaging ASSET x 4 TR/TE=3.2/1.4, Flip 45,38x38,8 mm, 224x224, 1 NEX, ZIP 512, ASSETx4, 10 slices total coverage entire LV Scan time = 2x 20 s BH Images acquired with Discovery MR450. Comparable to that which could be expected with Signa HDxt 1.5T

Express Exam user interface New UI platform shared across Optima and Discovery product lines Site protocols easily saved, filtered, archived, and shared. Automatically prescribe image processing Automatic launch of processing immediately after acquisition Toggle visibility of secondary parameters for new or experienced users

Waveforms display and Protocol Notes

Simplified protocol management Site specific protocols easily saved, filtered, archived, and shared... Save protocol as:

Automated linking, combining and processing Automatically prescribe the acquisition based on previous series. Following parameters can be automatically updated and applied for you: Scan locations Volume size and shape Slice thickness Slice spacing Saturation Shim volume

Inline linking, combining and processing Inline processing tasks immediately after the images are acquired, without user intervention.

Liberty Docking System productivity starts before the patient enters the scan room SAFETY One Technologist can remove a patient in less than 30 seconds. PRODUCTIVITY Prepare the patient outside the scan room and help improve workflow with two tables.

Liberty Docking System more than a table SERVICE EXPANSION Grow clinical services with additional tables. SAFETY One Technologist can remove a patient in less than 30 seconds. Sentinelle Dedicated Breast PRODUCTIVITY Prepare the patient outside the scan room and help improve workflow with two tables. Radiation Oncology Surgery & Intervention

Sentinelle dedicated breast table system Enhanced imaging & intervention Variable coil geometry adjusts to patient designed to enhance SNR, resolution, and coverage Open table design for enhanced biopsy access working space Detachable table designed to optimize patient workflow and privacy with off-line set-up and patient care

Radiation therapy treatment planning table system Flat table top replicates RT position and CT simulation designed to help reduce organ distortion Indexed table edge & Lok-bar designed to enable repeatable fixation Detachable table designed to optimize patient workflow with off-line simulation set-up

Built upon an entire network to help you get the most out of your investment from day one InSite* Remote Service Performance Solutions icenter* Asset Management TiP* Virtual Assist Remote Training TiP Onsite Applications Training *Trademark of General Electric Company

Built for upgradeability, uptime, and investment protection it s all about system longevity Built for upgradeability a little or a lot. Signa LX to Signa HDxt Signa EXCITE to Signa HDxt Signa HD to Signa HDxt CXK4 to Discovery MR450 Signa HDe to Optima MR360 Signa Horizon Signa Advantage 1983 Signa Signa LX Horizon Discovery MR450 Optima Edition Signa HDxt Signa HDi Signa HDx Signa HD Signa EXCITE