Etude POPART'MUS MRI Component

Size: px
Start display at page:

Download "Etude POPART'MUS MRI Component"

Transcription

1 TECHNICAL SURVEY Dear Investigators, This document is a Technical Survey which provides the teams of THERALYS and of the Pierre Wertheimer Neurological Hospital of Lyon with an overview of your site s imaging context. During this Study, each patient will have: One MRI scan performed at randomization visit, which takes place at the 6 th week of amenorrhea. This scan taking place during pregnancy, it will therefore be done without Gadolinium. Four post-delivery MRI scans performed at weeks: W4, W8, W12 and W24 post delivery. The following MRI sequences (with a slice thickness of mm, acquired parallelly to the ) will be available for each study: Proton Density (PD) and T2-weighted FLAIR Diffusion T1-weighted T1-weighted after a Gadolinium injection, only at W4, W8, W12 and W24 THERALYS will ensure that the image acquisition procedure implemented at your site complies with the Study s MRI protocol. The quality of the MRI scans will have a major impact on the overall quality of the Study. Please complete this Technical Survey and send it back to THERALYS either by fax using the following fax number: +.() or by filling this electronic document and by ing it back to: [email protected] Should you have any question or comment regarding this survey or related to the imaging component of the POPARTMUS Study in general, please do not hesitate to contact us: Luc BRACOUD - Projet Manager : [email protected] Tel: +.() : +.() Please note that to contact the THERALYS team, the following address can also be used: : [email protected] We thank you very much in advance for your precious collaboration and are looking forward to meeting you soon. THERALYS team. Abbreviations used in this document: AC-PC Anterior Commissure Posterior Commissure FTP File Transfer Protocol ADC Apparent Diffusion Coefficient Left-Right AP Anterior-Posterior NEX Number of Excitations DICOM Digital Imaging and Communications in Medicine NSA Number of Signal Averages EPI Echo Planar Imaging PD Proton Density FLAIR FLuid Attenuated Inversion Recovery SE Spin Echo FOV Field Of View TSE Turbo Spin Echo FSE Fast Spin Echo Page 1 of 5 THERALYS - Bioparc, 6 avenue Rockefeller Lyon - France : +.() : +.() : [email protected] POPARTMUS-25-2 EN 2.2

2 TECHNICAL SURVEY Clinical site City / Institution :.. Survey completed by: Date: MRI system Manufacturer:... Model: Version:. Can your MRI system export data in DICOM format on CDROMs? Are you able and willing to transfer the image data via File Transfer Protocol (FTP)? What storage medium is used by your site for onsite archiving of MRI data? Coil Manufacturer : Type:.. Gadolinium Injection Contrast agent used:.. Concentration :.. Type of injection (automatic / manual) and rate:... Diffusion sequence THERALYS will systematically generate Apparent Diffusion Coefficient (ADC) and Mean Diffusivity ( Trace ) maps from native diffusion-weighted images. Can your MRI system export directional images of the diffusion sequence (b images + b~1 s/mm 2 images per slice, that is to say 4 image series): Can your MRI system export ADC parametric maps? Can your MRI system export MD ( Trace ) parametric maps? Page 2 of 5 THERALYS - Bioparc, 6 avenue Rockefeller Lyon - France : +.() : +.() : [email protected] POPARTMUS-25-2 EN 2.2

3 Etude POPART MUS - - TECHNICAL SURVEY Clinical site City / Institution: The following table provides a common basis of acquisition parameters for all sites. The other parameters will be finalized depending on the manufacturer and model of your MRI system, following your answer to this survey. In the lower right part of each cell are indicated the values requested by the MRI protocol. Please confirm that you can fulfil these requirements. Comments: Orientation Number of slices Slice thickness (mm) Slice gap (mm) FOV (mm) Rect. FOV (%) Acquisition Matrix Number of acquisitions (NSA or NEX) Phase encoding direction Specific settings PD / T2 T1 and T1 Gado FLAIR Diffusion 4 1 FSE / TSE 4 1 SE % AP SE EPI b= et b=1 s/mm 2 directions Exportation of directional images Please see that full brain coverage is achieved for each sequence The acquisition will be parallel to the for all the sequences of the protocol The T1-weitghed sequence with Gadolinium injection will be the last to be performed, 5 minutes following the injection. The same contrast agent must be used for all the studies of a given patient Your comments: Page of 5 THERALYS - Bioparc, 6 avenue Rockefeller Lyon - France : +.() : +.() : [email protected] POPARTMUS-25-2 EN 2.2

4 CONTACT LIST Clinical site City / Institution: You may want us to contact other neuroradiologists or imaging technologists from your site. In such case, please use the following contact sheet to provide us with their contact information. Page 4 of 5 THERALYS - Bioparc, 6 avenue Rockefeller Lyon - France : +.() : +.() : [email protected] POPARTMUS-25-2 EN 2.2

5 CONTACT LIST Clinical site City / Institution: Page 5 of 5 THERALYS - Bioparc, 6 avenue Rockefeller Lyon - France : +.() : +.() : [email protected] POPARTMUS-25-2 EN 2.2

SITE IMAGING MANUAL ACRIN 6698

SITE IMAGING MANUAL ACRIN 6698 SITE IMAGING MANUAL ACRIN 6698 Diffusion Weighted MR Imaging Biomarkers for Assessment of Breast Cancer Response to Neoadjuvant Treatment: A sub-study of the I-SPY 2 TRIAL Version: 1.0 Date: May 28, 2012

More information

Musculoskeletal MRI Technical Considerations

Musculoskeletal MRI Technical Considerations Musculoskeletal MRI Technical Considerations Garry E. Gold, M.D. Professor of Radiology, Bioengineering and Orthopaedic Surgery Stanford University Outline Joint Structure Image Contrast Protocols: 3.0T

More information

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R GE 3.0T 3.0T WRIST Invivo 8CH Wrist Coil Sequence Ax T2 Cor PD Cor PDFS Cor T1 Cor PD (Small FOV) FOV (mm) 80 80 80 80 40 Matrix 384x224 384x256 320x256 384x320 320x192 Phase Direction RL RL RL RL RL #

More information

GE Medical Systems Training in Partnership. Module 12: Spin Echo

GE Medical Systems Training in Partnership. Module 12: Spin Echo Module : Spin Echo Spin Echo Objectives Review the SE PSD. Review the concepts of T, T, and T*. Spin Echo PSD RF Gz Gy 90 80 Gx Spin Echo - SE Spin echo is a standard pulse sequence on Signa MRi/LX and

More information

MRI SEQUENCES. 1 Gradient Echo Sequence

MRI SEQUENCES. 1 Gradient Echo Sequence 5 An MRI sequence is an ordered combination of RF and gradient pulses designed to acquire the data to form the image. In this chapter I will describe the basic gradient echo, spin echo and inversion recovery

More information

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs

More information

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: [email protected]

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: kturek@mri-tech.pl Cirrus 0.2T MRI for Everyone North America, Asia, Europe contact: [email protected] MRI-TECH inc. Cirrus MRI system for all your needs: Low costs Low maintenance High quality Open geometry Imaging of

More information

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi Diffusione e perfusione in risonanza magnetica E. Pagani, M. Filippi DW-MRI DIFFUSION-WEIGHTED MRI Principles Diffusion results from a microspic random motion known as Brownian motion THE RANDOM WALK How

More information

MRI for Paediatric Surgeons

MRI for Paediatric Surgeons MRI for Paediatric Surgeons Starship David Perry Paediatric Radiologist Starship Children s Hospital CHILDREN S HEALTH What determines the brightness of a pixel in MRI? i.e. What determines the strength

More information

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Excelart Vantage Magnet Configuration: Ultra-short-bore Strength (or W x H): 1.5 T Homogeneity, ppm V-RMS: Dimensions of maximum

More information

5 Factors Affecting the Signal-to-Noise Ratio

5 Factors Affecting the Signal-to-Noise Ratio 5 Factors Affecting the Signal-to-Noise Ratio 29 5 Factors Affecting the Signal-to-Noise Ratio In the preceding chapters we have learned how an MR signal is generated and how the collected signal is processed

More information

GUIDE TO SETTING UP AN MRI RESEARCH PROJECT

GUIDE TO SETTING UP AN MRI RESEARCH PROJECT GUIDE TO SETTING UP AN MRI RESEARCH PROJECT Formal requirements and procedures OVERVIEW This document is intended to help a principle investigator set up a research project using magnetic resonance imaging

More information

Overview. Optimizing MRI Protocols. Image Contrast. Morphology & Physiology. User Selectable Parameters. Tissue Parameters

Overview. Optimizing MRI Protocols. Image Contrast. Morphology & Physiology. User Selectable Parameters. Tissue Parameters Overview Optimizing MRI Protocols Clinical Practice & Compromises Geoffrey D. Clarke, Radiology Department University of Texas Health Science Center at San Antonio Pulse timing parameters for adjusting

More information

32-Channel Head Coil Imaging at 3T

32-Channel Head Coil Imaging at 3T 32-Channel Head Coil Imaging at 3T Thomas Benner Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA

More information

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications Safety Issue 3.0 T MRI Pro 3.0 T MRI Con Immediate fringe field surrounding magnet A ferromagnetic object inadvertently brought into the scan room will experience a sharp increase in attraction toward

More information

Current Industry Neuroimaging Experience in Clinical Trials Jerome Barakos, M.D.

Current Industry Neuroimaging Experience in Clinical Trials Jerome Barakos, M.D. Current Industry Neuroimaging Experience in Clinical Trials Jerome Barakos, M.D. Melbourne Australia March 28, 2012 Synarc Experience and Expertise Largest imaging service provider dedicated to clinical

More information

Unwarping Echo Planar Images Using CMTK 1 Release 1.2

Unwarping Echo Planar Images Using CMTK 1 Release 1.2 Unwarping Echo Planar Images Using CMTK 1 Release 1.2 Torsten Rohlfing October 1, 2012 Neuroscience Program, SRI International, Menlo Park, CA Abstract This document describes the workflow for unwarping

More information

Update: MRI in Multiple sclerosis

Update: MRI in Multiple sclerosis Nyt indenfor MS ved MR Update: MRI in Multiple sclerosis Hartwig Roman Siebner Danish Research Centre for Magnetic Resonance (DRCMR) Copenhagen University Hospital Hvidovre Dansk Radiologisk Selskabs 10.

More information

MRI DATA PROCESSING. Compiled by: Nicolas F. Lori and Carlos Ferreira. Introduction

MRI DATA PROCESSING. Compiled by: Nicolas F. Lori and Carlos Ferreira. Introduction MRI DATA PROCESSING Compiled by: Nicolas F. Lori and Carlos Ferreira Introduction Magnetic Resonance Imaging (MRI) is a clinical exam that is safe to the patient. Nevertheless, it s very important to attend

More information

Case Report: Whole-body Oncologic Imaging with syngo TimCT

Case Report: Whole-body Oncologic Imaging with syngo TimCT Case Report: Whole-body Oncologic Imaging with syngo TimCT Eric Hatfield, M.D. 1 ; Agus Priatna, Ph.D. 2 ; John Kotyk, Ph.D. 1 ; Benjamin Tan, M.D. 1 ; Alto Stemmer 3 ; Stephan Kannengiesser, Ph.D. 3 ;

More information

3/30/2013. Disclosure. Advanced Neuro MRI: Imaging Techniques and Protocol Optimization. MRI, 35 year ago. MRI Today. Outlines

3/30/2013. Disclosure. Advanced Neuro MRI: Imaging Techniques and Protocol Optimization. MRI, 35 year ago. MRI Today. Outlines http://www.magnet.fsu.edu Disclosure Advanced Neuro MRI: Imaging Techniques and Protocol Optimization Research funding provided by Siemens Healthcare. Chen Lin, PhD DABR Indiana University School of Medicine

More information

MRI Technical Operations Manual. Final Version 7.0 20.January.2015

MRI Technical Operations Manual. Final Version 7.0 20.January.2015 MRI Technical Operations Manual Final Version 7.0 20.January.2015 2 Table of Contents 1 Functional Magnetic Resonance Imaging... 3 1.1 MRI Acquisition Procedures... 3 1.2 MRI Local Read Requirement (Baseline

More information

Kap 8 Image quality, signal, contrast and noise

Kap 8 Image quality, signal, contrast and noise 4/5/ FYS-KJM 474 contrast SNR MR-teori og medisinsk diagnostikk Kap 8 Image qualit, signal, contrast and noise resolution vailable MRparameters speed Main source of noise in MRI: Noise generated within

More information

SMRT Student Scope Submission

SMRT Student Scope Submission SMRT Student Scope Submission Title and Author Title: Massive Disk Herniation of the Thoracic Vertebrae Author: Tamara N. Lewis E-mail: [email protected] Phone: (404)963-2304 Expected date of graduation:

More information

NEURO MRI PROTOCOLS TABLE OF CONTENTS

NEURO MRI PROTOCOLS TABLE OF CONTENTS TABLE OF CONTENTS NEURO MRI PROTOCOLS BRAIN...2 Brain 1 Screen... 2 Brain 2 Brain Tumor... 2 Brain 3 Brain Infection / Meningitis... 2 Brain 4 Trauma... 3 Brain 5 Hemorrhage... 3 Brain 6 Demyelinating

More information

Configuration and Use of the MR Knee Dot Engine

Configuration and Use of the MR Knee Dot Engine Configuration and Use of the MR Knee Dot Engine Kai Reiter (RT); Sebastian Auer (RT) Radiology Herne, Herne, Germany 1 42 MAGNETOM Flash 3/2011 www.siemens.com/magnetom-world We are a radiological joint

More information

MGH Adult Diffusion Data Scanning Protocols

MGH Adult Diffusion Data Scanning Protocols MGH Adult Diffusion Data Scanning Protocols Structural scans SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\AAHScout_64 TA:0:14 PAT:3 Voxel size:1.6 1.6 1.6 mm Rel. SNR:1.00 :fl

More information

The smart approach to digital MRI

The smart approach to digital MRI Philips Healthcare is part of Royal Philips Electronics How to reach us: www.philips.com/healthcare [email protected] Product information: www.philips.com/smartpathtodstream The smart approach to

More information

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research. ParaVision 6 The Next Generation of MR Acquisition and Processing for Preclinical and Material Research Innovation with Integrity Preclinical MRI A new standard in Preclinical Imaging ParaVision sets a

More information

Breast MRI Quality Control

Breast MRI Quality Control Donna M. Reeve, MS, DABR, DABMP Department of Imaging Physics Educational Objectives Discuss the importance of breast MRI quality control (QC). Provide an overview of the new ACR Breast MRI Accreditation

More information

The in-house dedicated Vet MRI. Vet -MR

The in-house dedicated Vet MRI. Vet -MR Vet-MR The in-house dedicated Vet MRI Vet -MR Welcome to the world of Vet-MR The Innovation in imaging Pets: > Why Vet-MR > Vet-MR: the reasons for success > Easy MRI With more than twenty years of experience

More information

Chapter 10. Summary & Future perspectives

Chapter 10. Summary & Future perspectives Summary & Future perspectives 123 Multiple sclerosis is a chronic disorder of the central nervous system, characterized by inflammation and axonal degeneration. All current therapies modulate the peripheral

More information

Standardized MRI Protocol for Brain Tumor Clinical Trials. Benjamin M. Ellingson, Ph.D. Assistant Professor of Radiology at UCLA

Standardized MRI Protocol for Brain Tumor Clinical Trials. Benjamin M. Ellingson, Ph.D. Assistant Professor of Radiology at UCLA Standardized MRI Protocol for Brain Tumor Clinical Trials Benjamin M. Ellingson, Ph.D. Assistant Professor of Radiology at UCLA Standardized MRI Protocol for Therapeutic Studies FDA Meeting in January

More information

Magnetic Resonance Imaging

Magnetic Resonance Imaging Magnetic Resonance Imaging What are the uses of MRI? To begin, not only are there a variety of scanning methodologies available, but there are also a variety of MRI methodologies available which provide

More information

MEDIMAGE A Multimedia Database Management System for Alzheimer s Disease Patients

MEDIMAGE A Multimedia Database Management System for Alzheimer s Disease Patients MEDIMAGE A Multimedia Database Management System for Alzheimer s Disease Patients Peter L. Stanchev 1, Farshad Fotouhi 2 1 Kettering University, Flint, Michigan, 48504 USA [email protected] http://www.kettering.edu/~pstanche

More information

runl I IUI%I/\L Magnetic Resonance Imaging

runl I IUI%I/\L Magnetic Resonance Imaging runl I IUI%I/\L Magnetic Resonance Imaging SECOND EDITION Scott A. HuetteS Brain Imaging and Analysis Center, Duke University Allen W. Song Brain Imaging and Analysis Center, Duke University Gregory McCarthy

More information

In vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance

In vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance In vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance imaging (MRI) systems Piotr A. Wielopolski Erasmus MC Department

More information

MR Imaging of Peritoneal Malignancy Russell N. Low, MD

MR Imaging of Peritoneal Malignancy Russell N. Low, MD MR Imaging of Peritoneal Malignancy Russell N. Low, MD From: Sharp and Children's MRI Center and Sharp HealthCare, 7901 Frost Street, San Diego, California, 92123. Phone: (858) 939-3600. Email: [email protected]

More information

Secretin Enhanced Imaging of the Pancreas

Secretin Enhanced Imaging of the Pancreas Secretin Enhanced Imaging of the Pancreas Pablo R. Ros, MD University Hospitals Case Medical Center Case Western Reserve University SCBT-MR Boston, MA October, 2012 [email protected] Disclosures

More information

Prepublication Requirements

Prepublication Requirements Issued Prepublication Requirements The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals

More information

In Practice Whole Body MR for Visualizing Metastatic Prostate Cancer

In Practice Whole Body MR for Visualizing Metastatic Prostate Cancer In Practice Whole Body MR for Visualizing Metastatic Prostate Cancer Prostate cancer is the second most common cancer in men worldwide, accounting for 15% of all new cancer cases. 1 Great strides have

More information

7/16/2010. Pulse Sequences and Acquisition Techniques for Breast MRI. Objectives. ACR Breast MRI Accreditation Program Launched May 2010

7/16/2010. Pulse Sequences and Acquisition Techniques for Breast MRI. Objectives. ACR Breast MRI Accreditation Program Launched May 2010 Pulse Sequences and Acquisition Techniques for Breast MRI ACR Breast MRI Accreditation Program Launched May 2010 Ron Price Vanderbilt University Medical Center Nashville, TN 37232 Information available:

More information

LONI De-Identification Policy

LONI De-Identification Policy The following defines how different file formats are de-identified with LONI tools. Each metadata attribute of each file can have the following operations performed: Operation keep Remove Replace Description

More information

The MRI Study Guide for Technologists

The MRI Study Guide for Technologists The MRI Study Guide for Technologists Kenneth S. Meacham The MRI Study Guide for Technologists With 51 Illustrations Springer-Verlag New York Berlin Heidelberg London Paris Tokyo Hong Kong Barcelona Budapest

More information

It takes two to connect the dots in MRI.

It takes two to connect the dots in MRI. It takes two to connect the dots in MRI. www.siemens.com/healthcare Tim+ Tim (Total imaging matrix) technology has made fast, flexible and accurate scans the rule, rather than the exception. But we know

More information

THE WIDEST WIDE-BORE IN THE INDUSTRY

THE WIDEST WIDE-BORE IN THE INDUSTRY THE WIDEST WIDE-BORE IN THE INDUSTRY The Widest Wide Bore in the Industry 74cm Oval Bore Provides a comfortable and spacious environment around the patient WIT Monitor Allows technologist to review and

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001 NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)

More information

DWI Case Study - QIBA PDF- MRI Technical Committee. What is IMI?

DWI Case Study - QIBA PDF- MRI Technical Committee. What is IMI? DWI Case Study - QIBA PDF- MRI Technical Committee QIBA Annual Meeting May 21, 2014 What is IMI? The Innovative Medicines Initiative (IMI) is the world s largest biomedical /healthcare public-private initiative

More information

Advanced MRI methods in diagnostics of spinal cord pathology

Advanced MRI methods in diagnostics of spinal cord pathology Advanced MRI methods in diagnostics of spinal cord pathology Stanisław Kwieciński Department of Magnetic Resonance MR IMAGING LAB MRI /MRS IN BIOMEDICAL RESEARCH ON HUMANS AND ANIMAL MODELS IN VIVO Equipment:

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001 NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009

More information

The History and Current Practice of Magnetic Resonance Imaging (MRI) A White Paper presented by the American Registry of Magnetic Resonance Imaging

The History and Current Practice of Magnetic Resonance Imaging (MRI) A White Paper presented by the American Registry of Magnetic Resonance Imaging The History and Current Practice of Magnetic Resonance Imaging (MRI) A White Paper presented by the American Registry of Magnetic Resonance Imaging Technologists (ARMRIT) (A Brief History of MRI & the

More information

Digital Image Processing with DragonflyPACS

Digital Image Processing with DragonflyPACS Digital Image Processing with DragonflyPACS The Smarter PACS The smartest image processing system in veterinary medicine. Outstanding image quality that s compliant with DICOM 3.0 standards. Compatible

More information

RF Coils... They ve Come a Long, Long Way

RF Coils... They ve Come a Long, Long Way GE Healthcare MR Field Notes The sensitivity area relates to the diameter of the coil. By Increasing coil size, the area of sensitivity also increases. But as with most MR princicloser a coil s position

More information

Electronic Supplementary Information

Electronic Supplementary Information Electronic Supplementary Material (ESI) for Physical Chemistry Chemical Physics. This journal is the Owner Societies 2016 Electronic Supplementary Information Achieving High Resolution and Controlling

More information

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project Software Tools for DICOM Media Exchange in Clinical Research: the SWABIK Project Software Tools for DICOM Media Exchange in Clinical Research: the SWABIK Project O. ElGazzar 1, M. Onken 1, M. Eichelberg

More information

Shorter Scanning Times Through Efficient Software. Annette Tuffs. Article from the customer magazine Medical Solutions, December 2010

Shorter Scanning Times Through Efficient Software. Annette Tuffs. Article from the customer magazine Medical Solutions, December 2010 Shorter Scanning Times Through Efficient Software Annette Tuffs Article from the customer magazine Medical Solutions, December 2010 www.siemens.com/healthcare-magazine Highlight Topic Efficiency: MRI A

More information

RE: Invitation for Bid (IFB) No. Q14-32 Type of Service: Magnetic Resonance Imaging System, Maintenance Agreement and Mobile MRI Unit. Addendum No.

RE: Invitation for Bid (IFB) No. Q14-32 Type of Service: Magnetic Resonance Imaging System, Maintenance Agreement and Mobile MRI Unit. Addendum No. VIA EMAIL DATE: June 16, 2014 TO: FROM: Prospective Proposers Maureen Crystal Director of Contracts RE: Invitation for Bid (IFB) No. Q14-32 Type of Service: Magnetic Resonance Imaging System, Maintenance

More information

PET and PET/CT in Clinical Trials

PET and PET/CT in Clinical Trials PET and PET/CT in Clinical Trials Nathan C. Hall, M.D., Ph.D. The Ohio State University Medical Center CALGB Imaging Core Lab CALGB Imaging Committee Outline Introduction to PET Positron Emitter Physics

More information

Brain Extraction, Registration & EPI Distortion Correction

Brain Extraction, Registration & EPI Distortion Correction Brain Extraction, Registration & EPI Distortion Correction What use is Registration? Some common uses of registration: Combining across individuals in group studies: including fmri & diffusion Quantifying

More information

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Magnetic Resonance Imaging V. Prof. Dr.

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Magnetic Resonance Imaging V. Prof. Dr. 1 12/9/2008 Page 1 Master s Program in Medical Physics Physics of Imaging Systems Basic Principles of Magnetic Resonance Imaging V Chair in Faculty of Medicine Mannheim University of Heidelberg Theodor-Kutzer-Ufer

More information

Radiologic Science Degree Completion Program. 2011-2012 Assessment Report

Radiologic Science Degree Completion Program. 2011-2012 Assessment Report Radiologic Science Degree Completion Program 2011-2012 Assessment Report I. Introduction II. III. Mission, Objectives, and Student Learning Outcomes a. Radiologic Science Degree Completion Program Mission

More information

Spatial Encoding Using Multiple rf Coils: SMASH Imaging and Parallel MRI

Spatial Encoding Using Multiple rf Coils: SMASH Imaging and Parallel MRI SPATIAL ENCODING USING MULTIPLE RF COILS: SMASH IMAGING AND PARALLEL MRI 1 Spatial Encoding Using Multiple rf Coils: SMASH Imaging and Parallel MRI Daniel K. Sodickson Beth Israel Deaconess Medical Center

More information

Basic Principles of Magnetic Resonance

Basic Principles of Magnetic Resonance Basic Principles of Magnetic Resonance Contents: Jorge Jovicich [email protected] I) Historical Background II) An MR experiment - Overview - Can we scan the subject? - The subject goes into the magnet -

More information

Neuroimaging module I: Modern neuroimaging methods of investigation of the human brain in health and disease

Neuroimaging module I: Modern neuroimaging methods of investigation of the human brain in health and disease 1 Neuroimaging module I: Modern neuroimaging methods of investigation of the human brain in health and disease The following contains a summary of the content of the neuroimaging module I on the postgraduate

More information

DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB)

DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB) DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS FLEXART-series/VISART-series/ EXCELART-series/SECOND CONSOLE (MIIMR0001EAB)

More information

Magnetic Resonance Imaging Level 1

Magnetic Resonance Imaging Level 1 MIAP1 Revised July 2015 MEDICAL IMAGING ADVISORY PANEL 1 Course Syllabus Magnetic Resonance Imaging Level 1 Page 1 of 13 MIAP1 MRI Course Syllabus Guide Under Revision 07 July 2015 Please refer to Medical

More information

510(k) Summary. This summary of 510(k) safety and effectiveness is being submitted in accordance with the requirements of 21 CFR 807.

510(k) Summary. This summary of 510(k) safety and effectiveness is being submitted in accordance with the requirements of 21 CFR 807. MAR, 2009 / \MLECH MRI-TECH Sp. z o.o., ul. Zielihska 3, 31-227 Krak6w, Poland MRI-TECH Canada, Inc. 206-3820 Cambie Street Vancouver BC V5Z 2X7 510(k) Summary This summary of 510(k) safety and effectiveness

More information

Why do we have so many brain coordinate systems? Lilla ZölleiZ WhyNHow seminar 12/04/08

Why do we have so many brain coordinate systems? Lilla ZölleiZ WhyNHow seminar 12/04/08 Why do we have so many brain coordinate systems? Lilla ZölleiZ WhyNHow seminar 12/04/08 About brain atlases What are they? What do we use them for? Who creates them? Which one shall I use? Brain atlas

More information

The Magnetic Resonance Imaging Examination

The Magnetic Resonance Imaging Examination The Magnetic Resonance Imaging Examination The purpose of The American Registry of Radiologic Technologists (ARRT ) Examination in Magnetic Resonance Imaging (MRI) is to assess the knowledge and cognitive

More information

Diagnostic performance of MRI in differentiating metastatic from acute osteoporotic compression fractures of the spine

Diagnostic performance of MRI in differentiating metastatic from acute osteoporotic compression fractures of the spine Diagnostic performance of MRI in differentiating metastatic from acute osteoporotic compression fractures of the spine Poster No.: C-1399 Congress: ECR 2013 Type: Scientific Exhibit Authors: J. Martel,

More information

Alessandro Laio, Maria d Errico and Alex Rodriguez SISSA (Trieste)

Alessandro Laio, Maria d Errico and Alex Rodriguez SISSA (Trieste) Clustering by fast search- and- find of density peaks Alessandro Laio, Maria d Errico and Alex Rodriguez SISSA (Trieste) What is a cluster? clus ter [kluhs- ter], noun 1.a number of things of the same

More information

Reproducibility of T1 and T2 Relaxation Times Calculated from Routine MR Imaging Sequences: Phantom Study

Reproducibility of T1 and T2 Relaxation Times Calculated from Routine MR Imaging Sequences: Phantom Study 277 Reproducibility of T1 and T2 Relaxation Times Calculated from Routine MR Imaging Sequences: Phantom Study Bent O. Kjos 1 Richard L. Ehman Michael Brant-Zawadki Measurement of nand T2 relaxation times

More information

7/22/2011. Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis. Objectives. Challenges in DCE Breast Imaging

7/22/2011. Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis. Objectives. Challenges in DCE Breast Imaging Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis Objectives Ron Price Vanderbilt University Medical Center Nashville, TN 37232 1. Review background of MRI breast cancer imaging 2. Present

More information

University Children s Hospital Basel

University Children s Hospital Basel Cooperation Siemens International Reference Center Pediatric MRI www.siemens.com/skyra University Children s Hospital Basel Siemens International Reference Center Pediatric MRI Answers for life. Partnering

More information

BIOMEDICAL ULTRASOUND

BIOMEDICAL ULTRASOUND BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic

More information

Monitoring Patient Radiation Dose in VA. Charles M. Anderson MD, PhD Chief Consultant for Diagnostic Services Veterans Health Administration

Monitoring Patient Radiation Dose in VA. Charles M. Anderson MD, PhD Chief Consultant for Diagnostic Services Veterans Health Administration Monitoring Patient Radiation Dose in VA Charles M. Anderson MD, PhD Chief Consultant for Diagnostic Services Veterans Health Administration TWENTY ONE/NOVEMBER 2011 Computed Tomography (CT), Magnetic Resonance

More information

REVIEW. Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging

REVIEW. Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging REVIEW Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging Matthew D. Robson, PhD, Peter D. Gatehouse, DPhil, Mark Bydder, PhD, and Graeme M. Bydder, MB, ChB Abstract: The background underpinning

More information

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants Master of Science Thesis in Biomedical Engineering, MPBME Karl-Johan Fredén Jansson Department of Signals and Systems

More information

An fmri study on reading Hangul and Chinese Characters by Korean Native Speakers

An fmri study on reading Hangul and Chinese Characters by Korean Native Speakers 언 어 치 료 연 구, 제14 권 제4호 Journal of Speech & Hearing Disorders 2005, Vol.14, No.4, 29 ~ 36 An fmri study on reading Hangul and Chinese Characters by Korean Native Speakers Hyo-Woon Yoon(Brain Science Research

More information

Embedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008

Embedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008 Embedded Systems in Healthcare Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008 About the Speaker Working for Philips Research since 1982 Projects

More information

Subjects: Fourteen Princeton undergraduate and graduate students were recruited to

Subjects: Fourteen Princeton undergraduate and graduate students were recruited to Supplementary Methods Subjects: Fourteen Princeton undergraduate and graduate students were recruited to participate in the study, including 9 females and 5 males. The mean age was 21.4 years, with standard

More information

The multitude of symptoms following a whiplash injury has given rise to much discussion because of the lack of objective radiological findings.

The multitude of symptoms following a whiplash injury has given rise to much discussion because of the lack of objective radiological findings. HELPFUL PERSONAL INJURY INFORMATION COURTESY OF RIVERVIEW CHIROPRACTIC FROM ABSTRACT: Dynamic kine magnetic resonance imaging in whiplash patients Pain Research and Management 2009 Nov-Dec 2009;Vol. 14,

More information

UMHS-PUHSC JOINT INSTITUTE

UMHS-PUHSC JOINT INSTITUTE Imaging Biomarkers for Staging and Assessing Response to Therapy in Multiple Myeloma Qian Dong, MD. Radiology University of Michigan Wei Guo, MD. Orthopedic Oncology Peking University Second Hospital Team

More information

Obtaining Knowledge. Lecture 7 Methods of Scientific Observation and Analysis in Behavioral Psychology and Neuropsychology.

Obtaining Knowledge. Lecture 7 Methods of Scientific Observation and Analysis in Behavioral Psychology and Neuropsychology. Lecture 7 Methods of Scientific Observation and Analysis in Behavioral Psychology and Neuropsychology 1.Obtaining Knowledge 1. Correlation 2. Causation 2.Hypothesis Generation & Measures 3.Looking into

More information

Medical Imaging. MRI Instrumentation, Data Acquisition, Image Reconstruction. Assistant Professor Department of Radiology, NYU School of Medicine

Medical Imaging. MRI Instrumentation, Data Acquisition, Image Reconstruction. Assistant Professor Department of Radiology, NYU School of Medicine G16.4426/EL5823/BE6203 Medical Imaging MRI Instrumentation, Data Acquisition, Image Reconstruction Riccardo Lattanzi, Ph.D. Assistant Professor Department of Radiology, NYU School of Medicine Department

More information

Moving Beyond RECIST

Moving Beyond RECIST Moving Beyond RECIST Ihab R. Kamel, M.D., Ph.D. [email protected] Associate Professor Clinical Director, MRI Department of Radiology The Johns Hopkins University School of Medicine Outline Standard measures

More information

PET/CT-MRI First clinical experience

PET/CT-MRI First clinical experience 20 th April 2013, Barcelona, Sp PET/CT-MRI First clinical experience Philippe Appenzeller, MD Staff Radiologist and Nuclear Medicine Physician Department Medical Imaging, University Hospital Zurich PET/CT-MR

More information

Brains Unlimited, UHF MRI, 3T, 7T, 9.4T

Brains Unlimited, UHF MRI, 3T, 7T, 9.4T Brains Unlimited, UHF MRI, 3T, 7T, 9.4T Erik van den Bergh, Siemens Nederland 2e Hans Boter symposium 1 november 2013 siemens.com/answers Komende 40 minuten o De bouw van een geavanceerd scannerlab o 3T

More information

Patient Prep Information

Patient Prep Information Stereotactic Breast Biopsy Patient Prep Information Imaging Services Cannon Memorial Hospital Watauga Medical Center Table Weight Limits for each facility Cannon Memorial Hospital Watauga Medical Center

More information

Normal Distribution. Definition A continuous random variable has a normal distribution if its probability density. f ( y ) = 1.

Normal Distribution. Definition A continuous random variable has a normal distribution if its probability density. f ( y ) = 1. Normal Distribution Definition A continuous random variable has a normal distribution if its probability density e -(y -µ Y ) 2 2 / 2 σ function can be written as for < y < as Y f ( y ) = 1 σ Y 2 π Notation:

More information

ADNI 2 Alzheimer s Disease Neuroimaging Initiative 3T MRI Technical Procedures Manual

ADNI 2 Alzheimer s Disease Neuroimaging Initiative 3T MRI Technical Procedures Manual 1 V1. 01_31_2011 ADNI 2 Alzheimer s Disease Neuroimaging Initiative 3T MRI Technical Procedures Manual 2 Table of Contents I. Contact Information...4 II. ADNI2 3T Study Overview..5 III. Site Qualification..7

More information