DC Ferrule Fuses 14x51, 22x58, 27x60 glb 440V DC



Similar documents
Semiconductor (AC) fuses

British BS 88 Fuses. Introduction

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable. Technical Data:

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Power Supplies 3. SDN-P DIN Rail Series

High Speed Fuses. High Speed Fuses

Actuator-Sensor-Interface

Plug-in relays Mini ISO relays

Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection

Solar circuit protection application guide. Complete and reliable solar circuit protection

NH DIN Dual Indication Fuse Links Class gg/gl, 690Vac, 2 to 800 Amps, Sizes 000 to 4 NH Series


Type: DILM9 10(24VDC) Article No.:

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Rotary Disconnect Switch Specifications

IEC and British Standard Fuses

BETA Protecting SITOR Semiconductor Fuses

Type: DILM32 10(24V50HZ) Article No.:

Photovoltaic System Overcurrent Protection

Electronic overload relay EF65, EF96 and EF146

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Manual motor starter MS116

Data Sheet. Electro-mechanical counters Hengstler 800 series

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Electronic overload relay EF19 and EF45

MAJORSINE Power Inverter

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Electro-pneumatic control valves

LAUBE TECHNOLOGY DRY REED RELAYS

Ultra Rapid Semiconductor Protection Fuses

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

IEC gg & am STANDARD LOW VOLTAGE FUSE

PSR The compact range Description

Technical catalogue. Modular DIN rail components Installation contactors

DS 600. A contact free flux gate based current measurement sensor 600A rms

Linear Luminaire with LED Series EXLUX 6402/2

BB800 Off-Grid Solar System

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

ELECTROMAGNETIC DISC BRAKES

Three-phase monitoring relay CM-PFE

DC Film Capacitors MKT Radial Potted Type

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Thermal-Magnetic Circuit Breaker M1-..

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Pluggable interface relays CR-P Pcb relays

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

DC Film Capacitor MKT Radial Potted Type

Circuit Breakers. NRC Series. NRC Series

AC and Pulse Film Foil Capacitors KP Radial Potted Type

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

EGSTON Standard E2xFxWx 12W

Manual Motor Starter MS 116 up to 16 A Technical Data

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

R.C.C.B. s two-pole LEXIC

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Catalog. Modular DIN rail components Installation contactors

Applications. diris_826_a_1_gb_cat

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue

KSC Series Sealed Tact Switch for SMT

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

ICON Server box installation manual Rev. 1.1

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

LED-INTA-0024V-41-F-O

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Rectifier circuits & DC power supplies

SPST-NO SPDT DPST-NO DPDT

Vario-Series Accessories

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

MCC. MMSZ4678 THRU MMSZ4716

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

36T Series Snap-Action Temperature Controls

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Single Output Switching Power Supply

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Control Devices Catalogue. Control Devices. Preferred and Standard Products

08. SEK IDC CONNECTORS

Relays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

48 SERIES Relay interface modules 10 A

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

SKR - industry relay

DC Film Capacitors MKT Radial Potted Type

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

CIN::APSE MICROMINIATURE D-SUB

Knob Potentiometer FEATURES. P16NP P16NM Panel Cutout. Thickness nut 2 mm washer 1.5 mm. Panel sealing ring 12 wrench Thread M10 x

Z-TRAUQ INC. Tel.: (450) Fax: (450)

Transcription:

DC Ferrule Fuses 4x5, x58, 7x6 glb 44V DC glb from to 6 A Dimensions 5 7 mini ø 4.3 ø 5 Weight 8 g 58 7 mini 6.3 7 mini ø. ø 5 ø 7 ø 5 Weight : 57 g Weight: 8 g Trip force: 4.5N at mm -.5N at 7mm Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog 4x5 x58 7x6 6 8 6 5 3 4 5 5 63 8 5 6 @ 44 V DC ka L/R = 3 ms @ 44 V DC ka L/R = 3 ms @ 44 V DC ka L/R = 3 ms.9.74.....4.6.4.9 3.3 3.9 4.9 6. 7.5.6 3.8.5.3.8.9...5.8 4. 5. 5.7 6.7 8.5.8 3. 4. CC 4.4 CP glb 4x5/ CC 4.4 CP glb 4x5/6 CC 4.4 CP glb 4x5/8 CC 4.4 CP glb 4x5/ CC 4.4 CP glb 4x5/ CC 4.4 CP glb 4x5/6 CC 4.4 CP glb 4x5/ CC 4.4 CP glb 4x5/5 CC 4.4 CP glb 4x5/3 CC 4.4 CP glb 4x5/4 CC 4.4 CP glb 4x5/5 CC 4.4 CP glb x58/5 CC 4.4 CP glb x58/63 CC 4.4 CP glb x58/8 CC 4.4 CP glb x58/ CC 4.4 CP glb 7x6/5 CC 4.4 CP glb 7x6/6 E757 Q9484 F757 G757 R9485 H7573 L3 J7574 S984 T98687 H766 L76968 M33 J98563 K9957 H9856 M7574 FD4GB44VT FD4GB44V6T FD4GB44V8T FD4GB44VT FD4GB44VT FD4GB44V6T FD4GB44VT FD4GB44V5T FD4GB44V3T FD4GB44V4T FD4GB44V5T FDGB44V5T FDGB44V63T FDGB44V8T FDGB44VT FD7GB44V5T FD7GB44V6T Minimum trip indicator ope voltage: V See Fuse Blocks, Fuse Holders and Fuse clips Pack: pieces SCDC /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses 4x5, x58, 7x6 glb 44V DC glb from to 6 A Electrical characteristics DC applications data L/R (ms) 9 8 7 6 5 4 3 3 4 5 6 7 t (s) 3 Time vs. current characteristics Left: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage - Size 4x5 - Size x58 3- Size 7x6 Max. AC voltage (5/6 Hz): 5 V with breaking capacity of ka 4 3 6 8 6 5 3 4 5 63 8 5 6 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - ± % tolerance for mean pre-arcing current - -3-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC3

DC Ferrule Fuses 7x6 grb 66V DC grb from.8 to A Dimensions 6.3 7 ø 7 ø 5 Weight : 8 g Trip force: 4.5N at mm -.5N at 7 mm Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog 7x6.8.5 3.5 4 5 6.3 8 6 5 3 4 5 63 8 @ 66 V DC 5 ka L/R = 5 ms.5.5.35.4.6.6.7.8..3.4.9.4.8 3.5 4.7 4.8 5.6 6.4 7.4 7.7.4.4.6.7..3.3.4 3.3 4. 4.7 6 8 8.3 9.6..9 3.7 CC 6.6 CP grb 7x6/.8 CC 6.6 CP grb 7x6/ CC 6.6 CP grb 7x6/.5 CC 6.6 CP grb 7x6/ CC 6.6 CP grb 7x6/3.5 CC 6.6 CP grb 7x6/4 CC 6.6 CP grb 7x6/5 CC 6.6 CP grb 7x6/6.3 CC 6.6 CP grb 7x6/8 CC 6.6 CP grb 7x6/ CC 6.6 CP grb 7x6/ CC 6.6 CP grb 7x6/6 CC 6.6 CP grb 7x6/ CC 6.6 CP grb 7x6/5 CC 6.6 CP grb 7x6/3 CC 6.6 CP grb 7x6/4 CC 6.6 CP grb 7x6/5 CC 6.6 CP grb 7x6/63 CC 6.6 CP grb 7x6/8 CC 6.6 CP grb 7x6/ CC 6.6 CP grb 7x6/ H98585 J98586 K98587 P9859 Q9859 R98593 T98595 Z986 L763 M763 L7573 N7633 C776 M75635 P7634 Q7635 R7636 P7996 S79964 T994 S7637 FD7GRB66V,8T FD7GRB66VT FD7GRB66V,5T FD7GRB66VT FD7GRB66V3,5T FD7GRB66V4T FD7GRB66V5T FD7GRB66V6,3T FD7GRB66V8T FD7GRB66VT FD7GRB66VT FD7GRB66V6T FD7GRB66VT FD7GRB66V5T FD7GRB66V3T FD7GRB66V4T FD7GRB66V5T FD7GRB66V63T FD7GRB66V8T FD7GRB66VT FD7GRB66VT Minimum trip indicator ope voltage: V See Fuse Blocks, Fuse Holders and Fuse clips Pack: 3 and pieces SCDC4 7/5

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses 7x6 grb 66V DC grb from.8 to A Electrical characteristics DC applications data L/R (ms) 9 8 7 6 5 4 3 t (s) 3 4 3 4 5 6 7 8 9 These curves indicate the maximum permissible value of time constant L/R as a function of the DC working voltage - 8 to A - 5 to 63 A 3-8 to A 4-.8 to 6.3 A Max. AC voltage (5/6 Hz): 66 V with 5 ka breaking capacity for I N 6.3A 66 V with ka breaking capacity for I N > 6.3A Time vs. current characteristics Peak arc voltage vs. working voltage Um (V) - L/R = 6 ms - L/R = 3 ms 5 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 4.8.5 3.5 4 5 6.3 8 6 5 3 4 5 63 8 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - ± % tolerance for mean pre-arcing current - -3-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC5

DC Ferrule Fuses x7 gr V DC grb-grc from 6 to 63A Dimensions 7 7 mini ø.6 ø 5 Weight : g Trip force: 4.5N at mm -.5N at 7 mm Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog x7 6 8 6 5 3 4 5 63* @ V DC ka L/R = ms...4 3. 3.7 4.4 5. 6. 7.3 8.5 9.6 3.5 3.8 4. 5.3 6.6 7.7 9.5 3. 5.5 7.4 CC 5 CP grb x7/6 D grb 6 VI CC 5 CP grb x7/8 D grb 8 VI CC 5 CP grb x7/ D grb VI CC 5 CP grb x7/ D grb VI CC 5 CP grb x7/6 D grb 6 VI CC 5 CP grb x7/ D grb VI CC 5 CP grb x7/5 D grb 5 VI CC 5 CP grb x7/3 D grb 3 VI CC 5 CP grc x7/4 D grc 4 VI CC 5 CP grc x7/5 D grc 5 VI CC 5 CP grc x7/63* D grc 63 VI* Z88 T88774 A89493 B89494 C89495 D89496 E89497 F89498 S86795 F8686 F83656* FDGBV6T FDGBV8T FDGBVT FDGBVT FDGBV6T FDGBVT FDGBV5T FDGBV3T FDGCV4T FDGCV5T FDGCV63T Minimum trip indicator ope voltage: 5 V * Use R.M.S. current less than 56 A when mounting in Fuse-disconnector See Fuse Blocks, Fuse Holders and Fuse clips Pack: 3 and pieces SCDC6 /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses x7 gr V DC grb-grc from 6 to 63A Electrical characteristics DC applications data 9 8 7 6 5 4 3 7 L/R (ms) Time vs. current characteristics t (s) 8 9 Above: Curve indicates the maximum permissible value of time constant L/R as a function of the DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of ka Peak arc voltage vs. working voltage Um (V) - L/R = 5 ms - L/R = 5 ms 3- L/R = 5 ms 4 6 8 3 Above: Curves indicate for various time constants L/R the peak arc voltage, which may appear accross the fuse terminals, vs. DC working voltage 4 3 6 8 6 5 3 4 5 63 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - ± 9% tolerance for mean pre-arcing current - -3-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC7

DC Ferrule Fuses x7 gr 5V DC grb - grd from.8 to 5 A Dimensions 7 7 mini ø.6 CC 55... ø 5 Weight: g Trip force: 4.5N at mm -.5N at 7 mm 7 ø.6 CC 5 Main Characteristics Size x7 Current I N ( A ).8.5 3.5 4 5.8.5 3.5 4 5 6 8 6 5 Breaking Capacity @ V DC ka L/R = ms @ 5 V DC 3 ka L/R = ms @ 5 V DC 3 ka L/R = 55 ms Watts loss.8 I N I N (W) (W).5.5.8.9..3.4.5.5.8.9..3.4 3.4 3.3 3.5 3.9 5 5.3 6.6.9.9.4.6...3.9.9.4.6...3 6.3 6. 6. 6.8 8.9 9.6 CC 55 CP grb x7/.8 CC 55 CP grb x7/ CC 55 CP grb x7/.5 CC 55 CP grb x7/ CC 55 CP grb x7/3.5 CC 55 CP grb x7/4 CC 55 CP grb x7/5 CC 5 CP grb x7/.8 CC 5 CP grb x7/ CC 5CP grb x7/.5 CC 5 CP grb x7/ CC 5 CP grb x7/3.5 CC 5CP grb x7/4 CC 5 CP grb x7/5 CC 5 CP grd x7/6 CC 5 CP grd x7/8 CC 5 CP grd x7/ CC 5 CP grd x7/ CC 5 CP grd x7/6 CC 5 CP grd x7/ CC 5 CP grd x7/5 D 5 grb.8 VI () D 5 grb VI () D 5 grb.5 VI () D 5 grb VI () D 5 grb 3.5VI () D 5 grb 4 VI () D 5 grb 5 VI () D 5 grb.8 V D 5 grb V D 5 grb.5 V D 5 grb V D 5 grb 3.5 V D 5 grb 4 V D 5 grb 5 V D 5 grd 6 V D 5 grd 8 V D 5 grd V D 5 grd V D 5 grd 6 V D 5 grd V D 5 grd 5 V Ref. E75743 F75744 G75745 B88367 H75746 J75747 C88368 J884 R79894 K8843 Y9943 L8844 Z9944 A9945 E884 Z8867 F8655 B8593 Q8457 D883 A843 Catalog FDGB5V,8T FDGB5VT FDGB5V,5T FDGB5VT FDGB5V3,5T FDGB5V4T FDGB5V5T FDGB5V,8 FDGB5V FDGB5V,5 FDGB5V FDGB5V3,5 FDGB5V4 FDGB5V5 FDGD5V6 FDGD5V8 FDGD5V FDGD5V FDGD5V6 FDGD5V FDGD5V5 Minimum trip indicator ope voltage: 5 V () Rating,8 to 5A with trip indicator arc. UL Recognized See Fuse Blocks, Fuse Holders and Fuse clips Pack: 3 and pieces SCDC8 /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses x7 gr 5V DC grb - grd from.8 to 5 A Electrical characteristics DC applications data 9 8 7 6 5 4 3 t (s) 4 3 L/R (ms) grb 4 grd 8 6 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of 5 ka Time vs. current characteristics grb without trip indicator.8.5 3.5 4 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 4 3 grb with trip indicator.8.5 3.5 4 5 Peak arc voltage vs. working voltage Um(V) 5 5 Curve : grd @ L/R = 3 ms Curve : grb @ L/R = 6 ms Curve 3: grd @ L/R = 5 ms Curve 4: grb @ L/R = 3 ms 4 3 6 8 6 5 Above: Curves indicate for various time constants L/R peak arc voltage which may appear across the fuse terminals, vs. DC working voltage a= 3 A=.6 B=.5 B=.6 Cf3=.8 grd without trip indicator a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 /4 3 3 3 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. SCDC9 ± 9% tolerance for mean pre-arcing current

DC Ferrule Fuses 36x7 gr V DC V DC grb-grc from 5 to A Size 36x7 Dimensions 7 7 mini ø 36 ø 5 Weight : 99 g Trip force: 4.5N at mm -.5N at 7 mm Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog 36x7 5 3 4 5 63 8 V ka ms V ka ms 5.3 6.4 6.5 8.7.5.9 3. 9.4.5.6 5.4 8.8.5 4. CC 5 CP grb 36x7/5 CC 5 CP grb 36x7/3 CC 5 CP grb 36x7/4 CC 5 CP grb 36x7/5 CC 5 CP grc 36x7/63 CC 5 CP grc 36x7/8 CC 5 CP grc 36x7/ H 8398 R 86495 G 89499 H 895 J 895 A 8365 Z 8365 FD36GBV5T FD36GBV3T FD36GBV4T FD36GBV5T FD36GCV63T FD36GCV8T FD36GCVT Minimum trip indicator ope voltage: 5 V See Fuse Blocks, Fuse Holders and Fuse clips Pack: 3 pieces SCDC /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses 36x7 gr V DC grb-grc from 5 to A Electrical characteristics DC applications data 9 8 7 6 5 4 3 7 4 L/R (ms) t (s) 8 grc 5 3 9 grb Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of ka Time vs. current characteristics 4 5 63 8 Peak arc voltage vs. working voltage Um (V) - L/R = 5 ms - L/R = 5 ms 3- L/R = 5 ms 4 6 8 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 3 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 ±7% tolerance for mean pre-arcing current - - -3-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC

DC Ferrule Fuses x9 gr 5V DC grc from 6 to 3 A Dimensions 9 7 mini ø.6 CC 59... ø 5 Weight: 76 g 9 ø.6 CC 5... Main Characteristics Weight: 76 g Trip force: 4.5N at mm -.5N at 7 mm Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog x9 6 8 6 5 3 6 8 6 5 3 @ 5 V DC 6 ka L/R = 4 ms 4.8 5.3 6.5 7. 8. 9.5 6 4.8 5.3 6.5 7. 8. 9.5 6 7.8 8.8.5.5 3 5 9.5 6 7.8 8.8.5.5 3 5 9.5 6 CC 59 CP grc x9/6 CC 59 CP grc x9/8 CC 59 CP grc x9/ CC 59 CP grc x9/ CC 59 CP grc x9/6 CC 59 CP grc x9/ CC 59 CP grc x9/5 CC 59 CP grc x9/3 CC 5 CP grc x9/6 CC 5 CP grc x9/8 CC 5 CP grc x9/ CC 5 CP grc x9/ CC 5 CP grc x9/6 CC 5 CP grc x9/ CC 5 CP grc x9/5 CC 5 CP grc x9/3 D83 V83738 G8745 Y849 N88378 Q87345 Z843 G859 Z89469 A8947 B8947 C8947 D89473 E89474 F89475 G89476 FDGC5V6T FDGC5V8T FDGC5VT FDGC5VT FDGC5V6T FDGC5VT FDGC5V5T FDGC5V3T FDGC5V6 FDGC5V8 FDGC5V FDGC5V FDGC5V6 FDGC5V FDGC5V5 FDGC5V3 Minimum trip indicator ope voltage: 9 V See Fuse Blocks, Fuse Holders and Fuse clips Pack: piece SCDC /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses x9 gr 5V DC grc from 6 to 3 A Electrical characteristics DC applications data 9 8 7 6 5 4 3 L/R (ms) 4 6 8 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 3 V with breaking capacity of 5 ka Time vs. current characteristics 45 3 5 Peak arc voltage vs. working voltage Um (V) 5 - L/R = 45 ms - L/R = 5 ms 5 Above: Curves indicate for various time constants L/R peak arc voltage which may appear across fuse terminals, vs. DC working voltage 4 6 8 6 5 3 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - ± 7% tolerance for mean pre-arcing current - -3-4 3 4 /4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. SCDC3

DC Ferrule Fuses 36x9 gr 5V DC grc - grd from 4 to A Dimensions 9 7 mini ø 36 CC 59... ø 5 Weight: 58 g 9 ø 36 CC 5... Weight: 58 g Trip force: 4.5N at mm -.5N at 7 mm Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog 36x9 4 5 63 8 4 5 63 8 @ 5 V DC 6 ka L/R = 6 ms @ 5 V DC ka L/R = 3 ms 4 6.5.6 8 3 4 6.5.6 8 3 6 3 38 33 4 6 3 38 33 4 CC 59 CP grc 36x9/4 CC 59 CP grc 36x9/5 CC 59 CP grc 36x9/63 CC 59 CP grd 36x9/8 CC 59 CP grd 36x9/ CC 5 CP grc 36x9/4 CC 5 CP grc 36x9/5 CC 5 CP grc 36x9/63 CC 5 CP grd 36x9/8 CC 5 CP grd 36x9/ M 849 N 84 P 84 N 34 Y 54 H 89477 J 89478 K 89479 Q 787 K 785 FD36GC5V4T FD36GC5V5T FD36GC5V63T FD36GD5V8T FD36GD5VT FD36GC5V4 FD36GC5V5 FD36GC5V63 FD36GD5V8 FD36GD5V Minimum trip indicator ope voltage: 9 V See Fuse Blocks, Fuse Holders and Fuse clips Pack: piece SCDC4 /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses 36x9 gr 5V DC grc - grd from 4 to A Electrical characteristics DC applications data 9 8 7 6 5 4 3 5 L/R (ms) A 5 B 5 3 A: with trip-indicator B: without trip-indicator Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage 4 3 Peak arc voltage vs. working voltage Um (V) 5 - L/R = 45 ms - L/R = 5 ms 5 5 Max. AC voltage (5/6 Hz): 3 V with breaking capacity of 5 ka Time vs. current characteristics 4 t (s) 4 5 63 8 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 ± 9% tolerance for mean pre-arcing current - - Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. -3-4 /4 3 4 SCDC5

DC Ferrule Fuses 36x5 gr V DC grb from.8 to 4 A Dimensions 55 43 ø 36 CC 9P... ø Trip force: 5 N at mm 5 Weight 667 g ø 36 CC... Weight 6 g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog 36x5.8.5 3.5 4 5 6 8 6 5 3 4 5 3 4 @ V DC 3 ka L/R = ms..8.8 4 5 5.3 6 7 7.6.5 5. 9.6 7. 7.6 5. 9.6.8 3 3.3 5 7 8.8 9 3 8 7.5 6 33.6 3 7.5 6 33.6 CC CP grb 36x5/.8 CC CP grb 36x5/ CC CP grb 36x5/.5 CC CP grb 36x5/ CC CP grb 36x5/3.5 CC CP grb 36x5/4 CC CP grb 36x5/5 CC CP grb 36x5/6 CC CP grb 36x5/8 CC CP grb 36x5/ CC CP grb 36x5/ CC CP grb 36x5/6 CC CP grb 36x5/ CC CP grb 36x5/5 CC CP grb 36x5/3 CC CP grb 36x5/4 CC 9P CP grb 36x5/ CC 9P CP grb 36x5/ CC 9P CP grb 36x5/ CC 9P CP grb 36x5/5 CC 9P CP grb 36x5/3 CC 9P CP grb 36x5/4 P 35 R 9396 S 9397 T 9398 V 9399 N 8495 Q 36 S 84955 V 9339 H 9357 W 93 X 93 H 8657 Y 844 X 844 W 8439 L 84949 M 98497 M 8495 R 8746 L 83 W 87373 FD36GBV,8 FD36GBV FD36GBV,5 FD36GBV FD36GBV3,5 FD36GBV4 FD36GBV5 FD36GBV6 FD36GBV8 FD36GBV FD36GBV FD36GBV6 FD36GBV FD36GBV5 FD36GBV3 FD36GBV4 FD36GBVK FD36GBVK FD36GBVK FD36GBV5K FD36GBV3K FD36GBV4K Minimum trip indicator ope voltage: 9 V See Fuse Blocks, Fuse Holders and Fuse clips Pack: piece SCDC6 /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses 36x5 gr V DC grb from.8 to 4 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) t (s) 4 9 8 7 6 5 4 3 4 5 6 7 8 9 3 4 Above: Curve indicates the maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 3 V with breaking capacity of 5 ka Time vs. current characteristics.8.5 3.5 4 5 6 8 6 4 3 6 5 : L/R = 45 ms : L/R = 5 ms 5 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 5 3 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 /4 3 3 3 Above: These curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. SCDC7 ± % tolerance for mean pre-arcing current

DC Ferrule Fuses 36x4 gr 4V DC grc from.8 to A Dimensions 4 ø 36 Weight: 84 g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Reference Catalog 36x4.8.5 3.5 4 5 6 8* * * 6* * @ 4 V DC 3 ka L/R = ms.5.6.4 3. 3.9 6. 9.6 3 5 5 8.6.5.7 4. 5. 6.4 6 9 3 6 7 33 CC 4 CP grc 36x4/.8 CC 4 CP grc36x4/ CC 4 CP grc 36x4/.5 CC 4 CP grc36x4/ CC 4 CP grc 36x4/3.5 CC 4 CP grc36x4/4 CC 4 CP grc36x4/5 CC 4 CP grc36x4/6 CC 4 CP grc36x4/8 CC 4 CP grc36x4/ CC 4 CP grc36x4/ CC 4 CP grc36x4/6 CC 4 CP grc36x4/ Z 93 R 37 S 38 Z 8943 T 39 A 8944 Y 9846 E 99847 V 4 G 98469 C 98396 Z 835 F 99848 FD36GC4V,8 FD36GC4V FD36GC4V,5 FD36GC4V FD36GC4V3,5 FD36GC4V4 FD36GC4V5 FD36GC4V6 FD36GC4V8 FD36GC4V FD36GC4V FD36GC4V6 FD36GC4V See Fuse Blocks, Fuse Holders and Fuse clips * Minimum breaking current = 5 IN Pack: piece SCDC8 /4

Protistor DC fuses Protistor DC fuses DC Ferrule Fuses 36x4 gr 4V DC grc from.8 to A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) t (s) 9 8 7 6 5 4 3 4 3 4 6 8 3 3 34 36 38 4.8.5 3.5 3 3:,8 à A Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 4 V with breaking capacity of 5 ka Time vs. current characteristics 4 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 4 3 8 6 4 6 8 6 : L/R = 3 ms 3 4 5 Above: Curves indicate for various time constants L/R the peak arc voltage, which may appear across fuse terminals, vs. DC working voltage a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - - - -3-3 -4 3 3 4 Above, left and right: Curves indicate, for each rated current, ± % tolerance for mean pre-arcing time vs. R.M.S. pre-arcing current pre-arcing current -4 /4 SCDC9

Sizes to 3 gr 75V DC Dimensions Size grc from 5 to 6 A Weight 75 g Weight 65 g Main Characteristics Size Current I N ( A ) 5 63 8 5 6 5 63 8 5 6 Breaking capacity @ 75 V= k A L/R = ms @ 9 V= k A L/R = 4 ms Watts loss.8 I N I N (W) (W) 4.4 5.7 7.3 9..5 5 4.4 5.7 7.3 9..5 5 8..4 3.4 6.7 7 8..4 3.4 6.7 7 Max. I t @ 9 V = L/R 4 ms IP = I N IP = 5 I N (A S) (A S) 45 755 5 35 485 45 755 5 35 485 85 5 45 4 65 85 5 45 4 65 CC 7,5 grc EF 5 CC 7,5 grc EF 63 CC 7,5 grc EF 8 CC 7,5 grc EF CC 7,5 grc EF 5 CC 7,5 grc EF 6 CC 7,5 grc TTF 5 CC 7,5 grc TTF 63 CC 7,5 grc TTF 8 CC 7,5 grc TTF CC 7,5 grc TTF 5 CC 7,5 grc TTF 6 Ref. Y84776 R857 Q856 P855 R864 N854 B84 Q84 Z9435 R84 P855 R8553 Catalog DGC75V5EF DGC75V63EF DGC75V8EF DGC75VEF DGC75V5EF DGC75V6EF DGC75V5TF DGC75V63TF DGC75V8TF DGC75VTF DGC75V5TF DGC75V6TF Microswitch: MC 3E -5N Ref. : D3 Pack: piece SCDC /4

Protistor DC fuses Protistor DC fuses Sizes to 3 gr 75V DC size grc from 5 to 6 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 6 7 8 9 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of 7 ka 4 6 8 4 4 6 8 : L/R = ms : L/R = 4 ms Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage Time vs. current characteristics t (s) 4 3 63 5 8 5 6 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - ± 7% tolerance for mean pre-arcing current - -3-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC

Sizes to 3 gr 75V DC Dimensions Sizes grc from to 5 A Weight 3 g Weight 88 g Main Characteristics Size Current I N ( A ) 5 5 Breaking Capacity @75 V DC ka L/R = ms @ 9 V DC ka L/R = 4 ms Watts loss.8 I N I N (W) (W).5 5.5.5 5.5 37.5 46.7 37.5 46.7 Max. I t @ 9 V = L/R 4 ms IP = I N IP = 5 I N (A S) (A S) 755 5 755 5 5 5 5 5 CC 7,5 grc EF CC 7,5 grc EF 5 CC 7,5 grc TTF CC 7,5 grc TTF 5 Ref. A867 M853 N855 Q855 Catalog DGC75VEF DGC75V5EF DGC75VTF DGC75V5TF Microswitch: MC 3E -5N Ref. : D3 Pack: piece SCDC /4

Protistor DC fuses Protistor DC fuses Sizes to 3 gr 75V DC Sizes grc from to 5 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 6 7 8 9 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of 7 ka 4 6 8 4 4 : L/R = ms : L/R = 4 ms 6 8 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage Time vs. current characteristics t (s) 4 3 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - ± 7% tolerance for mean pre-arcing current - Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. -3-4 /4 3 4 SCDC3

Sizes to 3 gr 75V DC Dimensions Size grc-grd from 5 to 5 A Weight: 3 g Weight: 5 g Main Characteristics Size Current I N ( A ) 5 35 35 4 45 5* 5 35 35 4 45 5* Breaking Capacity @75 V DC ka L/R = ms @ 9 V DC ka L/R = 4 ms Watts loss Max. I t @ 9 V = L/R 4 ms.8 I N I N IP = I N P = 5 I N (W) (W) (A S) (A S) 5.5 3.5 35 4.5 49 5 5.5 3.5 35 4.5 49 5 46.7 58 64.5 74.5 9 95 46.7 58 64.5 74.5 9 95.5 6 6.5 6 3. 6 4 6 6. 6 *.5 6 6.5 6 3. 6 4 6 6. 6 * 5, 4, 5, 6, 8,. 6 * 5, 4, 5, 6, 8,. 6 * CC 7,5 grc EF 5 CC 7,5 grc EF 35 CC 7,5 grc EF 35 CC 7,5 grc EF 4 CC 7,5 grd EF 45 CC 7,5 grd EF 5* CC 7,5 grc TTF 5 CC 7,5 grc TTF 35 CC 7,5 grc TTF 35 CC 7,5 grc TTF 4 CC 7,5 grd TTF 45 CC 7,5 grd TTF 5* Ref. A8733 B8733 W4 L89388 P95 Q95 B9437 M8549 G898 C9438 R953 S954 Catalog DGC75V5EF DGC75V35EF DGC75V35EF DGC75V4EF DGD75V45EF DGD75V5EF DGC75V5TF DGC75V35TF DGC75V35TF DGC75V4TF DGD75V45TF DGD75V5TF * Max. It @ 8 V=, L/R=4 ms and Breaking capacity = ka @ 75VDC/5ms Microswitch: MC 3E -5N Ref. : D3 Pack: piece SCDC4 /4

Protistor DC fuses Protistor DC fuses Sizes to 3 gr 75V DC Size grc-grd from 5 to 5 A Electrical characteristics DC applications data Peak arc voltage vs. working voltage L/R (ms) 9 8 7 6 5 4 3 5 6 7 8 9 : curve grc - grd 45A : curve grd 5A Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of 7 ka Time vs. current characteristics t (s) 4 3 5 35 35 4 a= 3 A=.6 B=.5 B=.6 Cf3=.8 grc 4 6 8 4 Um(V) 4 6 : L/R = ms : L/R = 4 ms 8 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) 4 3 45 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 grd - - -3 - - -3-4 -4 3 4 5 3 4 5 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. ± 7% tolerance for mean pre-arcing current /4 SCDC5

Sizes to 3 gr 75V DC Dimensions Size 3 grb-grc-grd from 5 to 8 A Weight: g Weight: 9 g Main Characteristics Size Current I N ( A ) 5 5 Breaking capacity @ 75 V DC ka L/R = ms @ 9 V DC ka L/R = 4 ms Watts loss Max. I t @ 9 V = L/R 4 ms.8 I N I N IP = I N P = 5 I N (W) (W) (A S) (A S) 5 5 93.5 93.5 5 6 5 6 6 6 maximum I t (A s) @ 8 V = L/R 4 ms I P = I N I P = 5 I N CC 7,5 grc 3 EF 5 CC 7,5 grc 3 TTF 5 Ref. M89389 D9439 Catalog D3GC75V5EF D3GC75V5TF 3 63 7 75 63 7 75 @ 75 V DC ka L/R = 5 ms 74 8 8 74 8 8 See max. ope current next page 7.5 6 6 6 7.5 6 6 6.5 6 6 6.5 6 6 6 maximum I t (A s) @ 66 V = L/R 3 ms I P = I N I P = 5 I N CC 7,5 grb 3 EF 63 CC 7,5 grb 3 EF 7 CC 7,5 grd 3 EF 75 CC 7,5 grb 3 TTF 63 CC 7,5 grb 3 TTF 7 CC 7,5 grd 3 TTF 75 B98556 Q789 F943 C98557 F944 H945 D3GB75V63EF D3GB75V7EF D3GD75V75EF D3GB75V63TF D3GB75V7TF D3GB75V75TF 8 8 @ 66 V DC ka L/R = 5 ms 9 9.5 6.5 6.6 6.6 6 CC 6.6 grb 3 EF 8 CC 6.6 grb 3 TTF 8 G944 J946 D3GB66V8EF D3GB66V8TF Microswitch: MC 3E -5N Ref. : D3 Pack: piece SCDC6 /4

Protistor DC fuses Protistor DC fuses Sizes to 3 gr 75V DC Size 3 grb-grc-grd from 5 to 8 A Electrical characteristics DC applications data Peak arc voltage vs. working voltage L/R (ms) : curve grc : curve grb-grd 3: curve grb ( 8 A ) Um(V) 9 8 7 6 5 4 3 3 5 6 7 8 9 4 6 8 4 4 6 8 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of 7 ka Time vs. current characteristics : L/R = ms : L/R = 4 ms Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) 4 5 63 7-75 8 3 a= 3 A=.5 B=.5 B=.5 Cf3=.8 Current (A) 63 55 7 6 75 6 8 65 Maximum ope current (A) ± 7% tolerance for mean pre-arcing current - - -3-4 3 4 5 Above: curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC7

Sizes x - x3 gr 75V DC Dimensions Size x grc - grd from 5 to A Weight: 85 g Main Characteristics Size Current I N ( A ) 5 63 8 9 x * Breaking Capacity @ 9V DC ka L/R = 4 ms @ 75 V DC ka L/R = ms Watts loss Max. I t @ 9 V = L/R 4 ms.8 I N I N IP = I N P = 5 I N (W) (W) (A S) (A S) 5 63 8 98 94 6 49 8 5 6 8 6.4 6 6 6 6.6 6.4 6 3. 6 maximum I t (A s) @ 8 V = L/R 4 ms I P = I N I P = 5 I N 4 9 5 6 * 4.8 6 * CC 7,5 grc TTF 5 CC 7,5 grc TTF 63 CC 7,5 grc TTF 8 CC 7,5 grd TTF 9 CC 7,5 grd TTF * Ref. Q 9473 R 9474 S 9475 T 955 V 956 Catalog DGC75V5TF DGC75V63TF DGC75V8TF DGD75V9TF DGD75VCTF Microswitch: MC 3E -5N Ref. : D3 * Max I t @ 8V = 75 VDC ka L/R = 5 ms and breaking capacity @75 VDC ka L/R = 5 ms Pack: piece SCDC8 /4

Protistor DC fuses Protistor DC fuses Sizes x - x3 gr 75V DC Size x grc - grd from 5 to A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 5 6 7 8 : curve grc - grd 9 : curve grd 9 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of 7 ka Time vs. current characteristics t (s) 5 63 8 4 6 8 4 4 6 8 : L/R = ms : L/R = 4 ms Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 9 4 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - - - -3-3 -4-4 3 4 5 3 4 5 Above, left and right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. ± 7% tolerance for mean pre-arcing current /4 SCDC9

Sizes x - x3 gr 75V DC Dimensions Size x3 grc-grb-grd from to 6 A Weight: 49 g Main Characteristics Size Current I N ( A ) x3 5 4 5 6 Breaking Capacity @ 75 V DC ka L/R = ms @ 9 V DC ka L/R = 4 ms @ 75 V DC ka L/R = 5 ms @ 66 V DC ka L/R = 5 ms Watts loss Max. I t @ 9 V = L/R 4 ms.8 I N I N IP = I N P = 5 I N (W) (W) (A S) (A S) 48 64 64 74 8 8 8 87 See max. ope current next page 6 3 6 4 6 4 6 48.6 6 4 6 maximum I t (A s) @ 8 V = L/R 4 ms I P = I N I P = 5 I N 6 6 8 6 8 6 maximum I t (A s) @ 66 V = L/R 3 ms I P = I N I P = 5 I N. 6 CC 7,5 grc 3 TTF CC 7,5 grb 3 TTF 5 CC 7,5 grb 3 TTF 4 CC 7,5 grd 3 TTF 5 CC 6.6 grb 3 TTF 6 Ref. Z 948 D 98558 B 9483 K 947 L 948 Catalog D3GC75VCTF D3GB75VCTF DGB75V4CTF D3GD75V5TF D3GB66V6TF Microswitch: MC 3E -5N Reference : D3 Pack: piece SCDC3 /4

Protistor DC fuses Protistor DC fuses Sizes x - x3 gr 75V DC Size x3 grc-grb-grd from to 6 A Electrical characteristics DC applications data L/R (ms) 9 8 7 6 5 4 3 5 6 7 8 Time vs. current characteristics t (s) 4 3 5 4 9 3: curve grc 4: curve grd 5: curvee grb 6 A Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage. Max. AC voltage (5/6 Hz): 5 V with breaking capacity of 7 ka 5 3 a= 3 A=.5 B=.5 B=.6 Cf3=.8 Current (A) 5 4 5 6 3 4 6 8 4 4 3 Peak arc voltage vs. working voltage Um(V) 4 6 8 : L/R = ms : L/R = 4 ms Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage Maximum ope current (A) 4/5 6 a= 3 A=.5 B=.5 B=.6 Cf3=.8 - - - - -3-3 -4 3 4 5 Above, left and right: Curves indicate, for each rated 3 4 5 ± 7% tolerance for mean pre-arcing current current, pre-arcing time vs. R.M.S. pre-arcing current. -4 /4 SCDC3

Sizes 7-7 - x7 SR V DC Size 7 SRF from to 5 A Dimensions 9 59,5 63 3 6 4 63 39 Weight: 68 g 38 9 3 Main Characteristics Size Current I N ( A ) 5 3 4 5 63 7 8 5 6 5 Breaking Capacity @ V DC ka L/R = 5 ms Watts loss.8 I N I N (W) (W) 4.5 7 8.5 5 8.5.5 8 34 35 46 5.5 8.5 6 33 37.5 44.5 54 64 65.5 89 Max. I t @ V L/R = 5 ms L/R = 45 ms (A S) (A S) 8 8 35 58 3 6 3 58 9 9 45 55 3 3 6 8 8 54 6 33 785 95 CC SRF 7 QF CC SRF 7 QF 5 CC SRF 7 QF 3 CC SRF 7 QF 4 CC SRF 7 QF 5 CC SRF 7 QF 63 CC SRF 7 QF 8 CC SRF 7 QF CC SRF 7 QF 5 CC SRF 7 QF 6 CC SRF 7 QF CC SRF 7 QF 5 Ref. C76638 S79435 T79436 V79437 W79438 X79439 Y7944 Z7944 A7944 B79443 C79444 D79445 Catalog D7SFVQF D7SFV5QF D7SFV3QF D7SFV4QF D7SFV5QF D7SFV63QF D7SFV8QF D7SFVQF D7SFV5QF D7SFV6QF D7SFVQF D7SFV5QF Microswitch: MC 3E -5N Ref. : D3 Pack: piece SCDC3 /4

Protistor DC fuses Protistor DC fuses Sizes 7-7 - x7 SR V DC Size 7 SRF from to 5 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 7 8 9 Time vs. current characteristics 3 4 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 9 V with breaking capacity of ka 6 8 4 3 : L/R = 45 ms : L/R = 5 ms 6 9 Above: Curves indicate for various time constants L/R the peak arc voltage,which may appear across fuse terminals, vs. DC working voltage t (s) 4 3 5 4 3 5 C C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 C 63 6 5 C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 C 8 5 C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 3 4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC33

Sizes 7-7 - x7 SR V DC Size 7 SRG from 6 to 4 A Dimensions 5 77 8.5 3 6 4 63 9 6 65 weight : 5 g 6 8 ø3 Main Characteristics Size Current I N ( A ) 7 6 5 35 4 4 Breaking Capacity @ V DC ka L/R = 5 ms Watts loss.8 I N I N (W) (W) 4 48 57 6 66 67 77.5 88 96 9 3 Max. I t @ V L/R = 5 ms L/R = 45 ms (A S) (A S) 455 9 8 36 785 54 34 38 CC SRG 7 QF 6 CC SRG 7 QF CC SRG 7 QF 5 CC SRG 7 QF 35 CC SRG 7 QF 4 CC SRG 7 QF 4 Ref. K7948 L7949 M7943 N7943 P7943 Q79433 Catalog D7SGV6QF D7SGVQF D7SGV5QF D7SGV35QF D7SGV4QF D7SGV4QF Microswitch: MC 3E -5N Ref. : D3 Pack: piece SCDC34 /4

Protistor DC fuses Protistor DC fuses Sizes 7-7 - x7 SR V DC Size 7 SRG from 6 to 4 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 7 8 9 3 4 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltag Max. AC voltage (5/6 Hz): 9 V with breaking capacity of ka Time vs. current characteristics 6 8 4 3 : L/R = 45 ms : L/R = 5 ms 6 9 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across the fuse terminals, vs. DC working voltage 4 3 C 35 4 C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 6 5 4 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 4 3 4 Above, left and right: These curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC35

Sizes 7-7 - x7 SR V DC Size x7 SRG from 5 to 84 A Dimensions 6 36 3 59.5 6 6 5 77 86.5 76.5 6 8 4 63 9 ø3 65 weight : 4 g Main Characteristics Size Current I N ( A ) x7 5 63 8 84 Breaking Capacity @ V DC ka L/R = 5 ms Watts loss.8 I N I N (W) (W) 6 39 4 3 7 75 Max. I t @ V L/R = 5 ms L/R = 45 ms (A S) (A S) 8 36 78 88 34 66.5 6.53 6 CC SRG 7 QF 5 CC SRG 7 QF 63 CC SRG 7 QF 8 CC SRG 7 QF 84 Ref. P77983 F79447 G79448 H79449 Catalog D 7 SG V 5 QF D 7 SG V 63 QF D 7 SG V 8 QF D 7 SG V 84 QF Microswitch: MC 3E -5N Ref. : D3 Pack: piece SCDC36 /4

Protistor DC fuses Protistor DC fuses Sizes 7-7 - x7 SR V DC Size x7 SRG from 5 to 84 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 7 8 9 3 4 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltag Max. AC voltage (5/6 Hz): 9 V with breaking capacity of ka Time vs. current characteristics 6 8 4 3 : L/R = 45 ms : L/R = 5 ms 6 9 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across the fuse terminals, vs. DC working voltage 4 3 63 84 a= 3 A=.6 B=.5 B=.6 Cf3=.8 5 8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 4 3 4 Above, left and right: These curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC37

Sizes - - x SR V DC Size SRC from to 5 A Dimensions 3 59.5 63 7 95 7 39 38 9 Weight : 9 g 3 Main Characteristics Size Current I N ( A ) Breaking Capacity 5 3 4 5 63 8 5 6 5 @ V= ka L/R = 5 ms Watts loss.8 I N I N (W) (W) 8.5 4.5 7.5.5 6 3 35 43 49 49.5 5 6 5 9.5 36 4 53.5 6.5 7.5 87.5 99 6 Max. I t @ 6 V L/R = 5 ms L/R = 45 ms (A S) (A S) 8 8 35 58 3 6 3 58 9 9 45 55 3 3 6 8 8 54 6 33 785 95 CC SRC QF CC SRC QF 5 CC SRC QF 3 CC SRC QF 4 CC SRC QF 5 CC SRC QF 63 CC SRC QF 8 CC SRC QF CC SRC QF 5 CC SRC QF 6 CC SRC QF CC SRC QF 5 Ref. J7945 K7945 L7945 M79453 N79454 P79455 Q79456 R79457 S79458 T79459 V7946 W7946 Catalog DSCCQF DSCC5QF DSCC3QF DSCC4QF DSCC5QF DSCC63QF DSCC8QF DSCCQF DSCC5QF DSCC6QF DSCCQF DSCC5QF Microswitch: MCR 3E -5N BS Ref. : G33 Pack: piece SCDC38 /4

Protistor DC fuses Protistor DC fuses Sizes - - x SR V DC Size SRC from to 5 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 4 6 Time vs. current characteristics 8 4 Above: Curve indicates the maximum permissible value of time constant L/R as a function of the DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of ka 4 35 3 5 5 4 8 : L/R = 45 ms : L/R = 5 ms 6 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across the fuse terminals, vs. DC working voltage t (s) 4 3 5 4 3 5 C C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 63 6 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 8 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 3 4 3 4 Above, left to right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC39

Sizes - - x SR V DC Size SRD from 6 to 4 A Dimensions 8 77 8.5 3 73 95 7 9 6 65 6 8 ø3 Weight : 8 g Main Characteristics Size Current I N ( A ) 6 5 35 4 Breaking capacity @ 8 V DC ka L/R = 3 ms @ V DC k A L/R = 5 ms Watts loss.8 I N I N (W) (W) 5.5 6.5 69 74 87 8 3 5 75 Max. I t @ 6 V L/R = 5 ms L/R = 45 ms (A S) (A S) 5 6 5 7 9 5 44 87 38 CC SRD QF 6 CC SRD QF CC SRD QF 5 CC SRD QF 35 CC SRD QF 4 Ref. D76639 X7946 Y79463 Z79464 A79465 Catalog DSDC6QF DSDCQF DSDC5QF DSDC35QF DSDC4QF Microswitch: MCR 3E -5N BS Ref. : G33 Pack: piece SCDC4 /4

Protistor DC fuses Protistor DC fuses Sizes - - x SR V DC Size SRD from 6 to 4 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 4 6 8 4 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of ka Time vs. current characteristics 4 35 3 5 5 4 8 : L/R = 45 ms : L/R = 5 ms 6 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) 4 3 C 35 C' a= 3 A=.6 B=.3 B=.6 Cf3=.8 t (s) 4 3 C 6 5 4 C' a= 3 A=.6 B=.3 B=.6 Cf3=.8 - - - - -3-3 -4 3 4-4 3 4 Above, left and right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC4

Sizes - - x SR V DC Size x SRD from 5 to 8 A Dimensions 95 5 3 59.5 6 6 86.5 76.5 6 8 4 63 9 ø3 65 Weight : 335 g Main Characteristics Size Current I N ( A ) x 5 63 8 Breaking capacity @ 8 V DC ka L/R = 3 ms @ V DC k A L/R = 5 ms Watts loss.8 I N I N (W) (W) 45 55 8 74 34 367 Max. I t @ 6 V L/R = 5 ms L/R = 45 ms (A S) (A S) 468 876 348 8 CC SRD QF 5 CC SRD QF 63.5 CC SRD QF 8 Ref. E7664 F7664 V9666 Catalog DSDC5QF DSDC63QF DSDC8QF Microswitch: MCR 3E -5N BS Ref. : G33 Pack: piece SCDC4 /4

Protistor DC fuses Protistor DC fuses Sizes - - x SR V DC Size x SRD from 5 to 8 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 4 6 8 4 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 5 V with breaking capacity of ka Time vs. current characteristics 4 35 3 5 5 4 8 : L/R = 45 ms : L/R = 5 ms 6 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) 4 3 5 8 C C' a= 3 A=.6 B=.3 B=.6 Cf3=.8 t (s) 4 3 63 C C' a= 3 A=.6 B=.3 B=.6 Cf3=.8 - - - - -3-3 -4 3 4-4 3 4 Above, left and right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC43

Sizes 3-3 - x3 gr Brackets size 3-75 to V DC grc-gre from 6 to 5 A Dimensions 3 7 46 68 59.5 63 48 58 38 9 Weight: 5 g 3 Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog 6 8 6 @ 75 V DC 3 ka L/R = 3 ms 3.4 4.4 5.8 6 6.7 6 8.6 CC 7,5 grc 3 QF 6 CC 7,5 grc 3 QF 8 CC 7,5 grc 3 QF CC 7,5 grc 3 QF CC 7,5 grc 3 QF 6 P83733 Q83734 M89435 R87898 N89436 D3GC7C6QF D3GC7C8QF D3GC7CQF D3GC7CQF D3GC7C6QF 3 5 3 4 5 63 8 @ V DC 3 ka L/R = 3 ms 7.9 3.5 6 9 3.5 8.5 4 8 4 9 34 4.5 5.5 CC grc 3 QF CC grc 3 QF 5 CC grc 3 QF 3 CC grc 3 QF 4 CC grc 3 QF 5 CC grc 3 QF 63 CC grc 3 QF 8 R8693 S86933 T86934 V86935 W86936 X86937 Y86938 D3GCCQF D3GCC5QF D3GCC3QF D3GCC4QF D3GCC5QF D3GCC63QF D3GCC8QF 8 5 @ V DC 3 ka L/R = 4 ms @ 8 V= ka L/R = ms 8 3 4 5 55 CC gre 3 QF 8 CC gre 3 QF CC gre 3 QF 5 P7575 Q75753 R75754 D3GEC8QF D3GECQF D3GEC5QF Microswitch: MC R 3E -5N Ref. : G33 Pack: piece SCDC44 /4

Protistor DC fuses Protistor DC fuses Sizes 3-3 - x3 gr Brackets size 3-75 to V DC grc-gre from 6 to 5 A Electrical characteristics DC applications data 9 8 7 6 5 4 3 L/R (ms) 3 6 3 Curve grc 75 V 4 Curve grc V 5 Curve gre V Time vs. current characteristics Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz):,7 V with breaking capacity of 8 ka 4 4 Peak arc voltage vs. working voltage Um(V) 5 Curve grc : L/R = 3 ms Curve gre : L/R = 5 ms Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) grc grc 8 5 gre 4 3 6 8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 6 5 3 4 5 63 8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 4 3 4 3 4 Above, left to right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current ± % tolerance for mean pre-arcing current /4 SCDC45

Sizes 3-3 - x3 gr Blades size 3-75 to V DC Size 3 grc from to 8 A Dimensions 39 8 4 8 5 348 3 Weigth: 5 g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog 6 @ 75 V DC 3 ka L/R = 3 ms 5.8 6 6.7.6 CC 7 CV3 grc 3PSP CC 7 CV3 grc 3PSP CC 7 CV3 grc 3PSP 6 Y8887 X86 L86996 D 3 GC 7C P D 3 GC 7C P D 3 GC 7C 6P 3 5 3 4 5 63 8 @ V DC 3 ka L/R = 3 ms 7.9 3.5 6 9 3.5 8.5 4 8 4 9 34 4.5 5.5 CC CV3 grc 3PSP CC CV3 grc 3PSP 5 CC CV3 grc 3PSP 3 CC CV3 grc 3PSP 4 CC CV3 grc 3PSP 5 CC CV3 grc 3PSP 63 CC CV3 grc 3PSP 8 K86995 Q8894 J86994 M86997 G8699 F8699 E8699 D 3 GC C P D 3 GC C 5P D 3 GC C 3P D 3 GC C 4P D 3 GC C 5P D 3 GC C 63P D 3 GC C 8P Pack: piece Microswitch MC R 3E -5N BS Reference number: J35 SCDC46 /4

Protistor DC fuses Protistor DC fuses Sizes 3-3 - x3 gr Blades size 3-75 to V DC Size 3 grc-gre from to 56 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 4 3 6 3 Curve grc 75 V 4 Curve gre V Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage 4 Curve grc : L/R = 3 ms Max. AC voltage (5/6 Hz): 7 V with breaking capacity of 8 ka Time vs. current characteristics Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across the fuse terminals, vs. DC working voltage t (s) 4 6 5 3 4 5 63 8 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 ±% tolerance for mean pre-arcing current - - -3-4 3 4 Above, left and right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current 7/5 SCDC47

Sizes 3-3 - x3 gr Brackets size 3 - V DC grc-gre from to 8 A Dimensions 86.5 5 3 9 8 46 68 74 77 6 8 ø3 Weigth: 44 g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog 5 6 @ V DC 3 ka L/R = 3 ms 3 37 47.5 58.5 7 93 CC grc 3 QF CC grc 3 QF 5 CC grc 3 QF 6 N8699 P8693 Q8693 D3GCCQF D3GCC5QF D3GCC6QF 3 6 5 8 @ V DC 3 ka L/R = 4 ms @ 8 V DC ka L/R = ms 4 48 57 6 7 8 95 CC gre 3 QF 6 CC gre 3 QF CC gre 3 QF 5 CC gre 3 QF 8 S75755 T75756 V75757 W75758 D3GEC6QF D3GECQF D3GEC5QF D3GEC8QF Microswitch MC R 3E -5N BS Reference number: J35 SCDC48 /4

Protistor DC fuses Protistor DC fuses Sizes 3-3 - x3 gr Brackets size 3 - V DC grc-gre from to 8 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 7 V with breaking capacity of 8 ka 4 3 6 3 Curve grc V 4 Curve gre V Time vs. current characteristics 4 Curve grc : L/R = 3 ms Curve gre : L/R = 5 ms Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across the fuse terminals, vs. DC working voltage t (s) grc t (s) 6 5 8 gre 4 5 6 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - - - -3-3 -4 3 4 5-4 3 4 5 Above, left and right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current ±% tolerance for mean pre-arcing current /4 SCDC49

Sizes 3-3 - x3 gr Blades size x3 - V DC grc-gre from to 56 A Dimensions 77 5 9 83.5 6 83.5 9 8 46 68 6 74,5 6 8 ø3 Weigth: g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog 5 @ V DC 3 ka L/R = 3 ms 6 74 7 44 CC grc 3 QF CC grc 3 QF 5 B7993 C7994 D3GCCQF D3GCC5QF x3 35 4 5 56 @ V DC 3 ka L/R = 4 ms @ 8 V DC ka L/R = ms 84 96 5 4 6 9 CC gre 3 QF 35 CC gre 3 QF 4 CC gre 3 QF 5 CC gre 3 QF 56 X75759 Y7576 Z7576 A7576 D3GEC35QF D3GEC4QF D3GEC5QF D3GEC56QF Pack: piece Microswitch MC R 3E -5N BS Reference number: J35 SCDC5 /4

Protistor DC fuses Protistor DC fuses Sizes 3-3 - x3 gr Blades size x3 - V DC grc-gre from to 56 A Electrical characteristics DC applications data L/R (ms) 3 Curve grc V 4 Curve gre V Peak arc voltage vs. working voltage Um(V) Time vs. current characteristics t (s) 4 3 9 8 7 6 5 4 3 5 6 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 7 V with breaking capacity of 8 ka 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 grc t (s) 4 3 4 35 4 5 56 Curve grc : L/R = 3 ms Curve gre : L/R = 5 ms a= 3 A=.6 B=.5 B=.6 Cf3=.8 gre Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across the fuse terminals, vs. DC working voltage - - - - -3-3 -4 3 4 5 /4 Above, left and right: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current -4 3 4 5 ±% tolerance for mean pre-arcing current SCDC5

Sizes 3-3 - x3 SR Brackets size 3-4V DC SRE from to 8 A Dimensions 9 3 7 46 68 47.5 63 48 58 38 9 Weight: 5 g 3 Main Characteristics Size Current I N ( A ) 3 5 3 4 5 63 8 5 6 8 Breaking Capacity @ 4 V DC ka L/R = 5 ms @ V DC ka L/R = 45 ms Watts loss.8 I N I N (W) (W) 8 6 3 35 38 4 49 5 5 36 4 43 5 6 69 75 8 95 96 98 Max. I t @ V L/R = 5 ms L/R = 45 ms (A S) (A S) 5 6 3 53 75 65 37 8 4 34 57 6 46 54 9 3 9 65 4 5 6 CC 4 SRE 3 QF CC 4 SRE 3 QF 5 CC 4 SRE 3 QF 3 CC 4 SRE 3 QF 4 CC 4 SRE 3 QF 5 CC 4 SRE 3 QF 63 CC 4 SRE 3 QF 8 CC 4 SRE 3 QF CC 4 SRE 3 QF 5 CC 4 SRE 3 QF 6 CC 4 SRE 3 QF 8 Ref. X7599 W7598 G7947 H7947 J79473 K79474 L79475 M79476 N79477 P79478 Q79479 Catalog D3SE4CQF D3SE4C5QF D3SE4C3QF D3SE4C4QF D3SE4C5QF D3SE4C63QF D3SE4C8QF D3SE4CQF D3SE4C5QF D3SE4C6QF D3SE4C8QF Pack: piece Microswitch MC R 3E -5N BS Ref. : J35 SCDC5 /4

Protistor DC fuses Protistor DC fuses Sizes 3-3 - x3 SR Brackets size 3-4V DC SRE from to 8 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 4 6 8 Time vs. current characteristics 4 6 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): V with breaking capacity of 8 ka 5 4 3 4 8 : L/R = 45 ms : L/R = 5 ms 6 4 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) t (s) 3 5 6 63 5 4 8 5 8 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - - - -3-3 -4 3 4-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC53

Sizes 3-3 - x3 SR Brackets size 3-4V DC SRD - SRF from 6 to 4 A Dimensions 86.5 5 3 9 8 46 68 74 77 6 8 ø3 Weigth: 83 g Main Characteristics Size 3 Current I N ( A ) 6 5 35 35 4 Breaking Capacity @ 4 V DC ka L/R = 5 ms @ V DC ka L/R = 45 ms Watts loss.8 I N I N (W) (W) 7 76 9 94 95 96 4 49 79 86 87 88 Max. I t @ V L/R = 5 ms L/R = 45 ms (A S) (A S) 8,5 38, 68, 5, 3, 95, 3, 66,, 5, 4, 35, CC 4 SRD 3 QF 6 CC 4 SRD 3 QF CC 4 SRD 3 QF 5 CC 4 SRD 3 QF 35 CC 4 SRD 3 QF 35 CC 4 SRF 3 QF 4 Ref. J 76644 R7948 S7948 T7948 V79483 V7597 Catalog D3SD4C6QF D3SD4CQF D3SD4C5QF D3SD4C35QF D3SD4C35QF D3SF4C4QF Microswitch MC R 3E -5N BS Ref. : J35 Pack: piece SCDC54 /4

Protistor DC fuses Protistor DC fuses Sizes 3-3 - x3 SR Brackets size 3-4V DC SRD - SRF from 6 to 4 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 4 6 8 Time vs. current characteristics 4 6 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): V with breaking capacity of 8 ka t (s) 4 3 35 C C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 5 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 4 8 : L/R = 45 ms : L/R = 5 ms 6 4 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage SRD SRD SRF 6 C 5 35 C' 4 C C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 4 3 4 5 5 5 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC55

Sizes 3-3 - x3 SR size x3-4v DC SRD - SRF from 4 to 8 A Dimensions 77 5 3 83.5 6 83.5 9 8 46 68 6 74,5 6 8 ø3 Weight: 44 g Main Characteristics Size x3 Current I N ( A ) 4 5 63 7 8 Breaking Capacity @ 4 V DC ka L/R = 5 ms @ V DC ka L/R = 45 ms Watts loss.8 I N I N (W) (W) 6 89 97 5 33 376 39 393 395 Max. I t @ V L/R = 5 ms L/R = 45 ms (A S) (A S) 55, 75, 6, 9, 78, 65, 48, 6.6 6.3 6 CC 4 SRD 3 QF 4 CC 4 SRD 3 QF 5 CC 4 SRD 3 QF 63 CC 4 SRD 3 QF 7 CC 4 SRF 3 QF 8 Ref. K8495 L8496 M8497 N8498 T7596 Catalog D3SD4C4QF D3SD4C5QF D3SD4C63QF D3SD4C7QF D3SF4C8QF Microswitch MC R 3E -5N BS Ref. : J35 Pack: piece SCDC56 /4

Protistor DC fuses Protistor DC fuses Sizes 3-3 - x3 SR size x3-4v DC SRD - SRF from 4 to 8 A Electrical characteristics DC applications data L/R (ms) Peak arc voltage vs. working voltage Um(V) 9 8 7 6 5 4 3 4 6 8 Time vs. current characteristics 4 6 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): V with breaking capacity of 8 ka t (s) 4 3 4 63 C C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 5 4 3 a= 3 A=.6 B=.5 B=.6 Cf3=.8 4 8 : L/R = 45 ms : L/R = 5 ms 6 4 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage SRD SRD SRF 5 7 C C' 8 C C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 4 3 4 5 5 5 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current. /4 SCDC57

Sizes 6-6 - x6 gr Brackets size 6-35 to 4 V DC grb-grd from 6 to 5 A Dimensions 9 3 365 394 46 47.5 63 48 58 38 9 Weight: 9 g 3 Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog 6 6 8 6 5 3 4 5 63 8 8 5 @ 35 V DC 3 ka L/R = 3 ms @ 4 V DC 3 ka L/R = 3 ms @ 4 V DC 3 ka L/R = 5 ms 5.3 7. 3. 4 8 5.5 35 9 4 5 39 5.5 63 9.5.7 8.5 4 5.4 3.5 46 63 5 76.5 9 67 88 CC 35 grb 6 QF 6 CC 35 grb 6 QF 8 CC 35 grb 6 QF CC 35 grb 6 QF CC 35 grb 6 QF 6 CC 35 grb 6 QF CC 35 grb 6 QF 5 CC 4 grb 6 QF 3 CC 4 grb 6 QF 4 CC 4 grb 6 QF 5 CC 4 grb 6 QF 63 CC 4 grb 6 QF 8 CC 4 grd 6 QF 8 CC 4 grd 6 QF CC 4 grd 6 QF 5 S83736 R83735 N8939 V8 P8939 Q8939 R89393 A86963 B86964 C86965 D86966 E86967 B75763 C75764 D75765 D6GB35C6QF D6GB35C8QF D6GB35CQF D6GB35CQF D6GB35C6QF D6GB35CQF D6GB35C5QF D6GB4C3QF D6GB4C4QF D6GB4C5QF D6GB4C63QF D6GB4C8QF D6GD4C8QF D6GD4CQF D6GD4C5QF Pack: piece Microswitch MC R 3E -5NBS Ref. : J35 SCDC58 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 gr Brackets size 6-35 to 4 V DC grb-grd from 6 to 5 A Electrical characteristics DC applications data Peak arc voltage vs. working voltage 9 8 7 6 5 4 3 4 L/R (ms) 8 3 3 36 3 : 35 V grb 4 : 4 V grb 5 : 4 V grd Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 36 V with breaking capacity of 3 ka Time vs. current characteristics 5 4 4 44 48 8 6 4 Um(V) 3 4 5 : L/R = 3 ms-35-4 V grb : L/R = 5 ms 4 V grd Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) grb grb 8 5 grd 4 3 6 8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 6 5 3 4 5 63 8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 a= 3 A=.6 B=.5 B=.6 Cf3=.8 - - -3-4 3 4 3 4 Above: Curves indicate, for each rated current, the pre-arcing time vs. the R.M.S. pre-arcing current. 3 4 5 ± % tolerance for mean pre-arcing current /4 SCDC59

Sizes 6-6 - x6 gr Blades size 6-35 to 4 V DC grb from to 8 A Dimensions 39 8 4 366 399 496 3 Weigth: 44 g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog 6 6 5 3 4 5 63 8 @ 35 V DC 3 ka L/R = 3 ms @ 4 V DC 3 ka L/R = 3 ms. 3. 4 8 5.5 35 9 4 5 8.5 4 5.4 3.5 46 63 5 76.5 9 CC 35 CV3 grb 6 PSP CC 35 CV3 grb 6 PSP CC 35 CV3 grb 6 PSP 6 CC 35 CV3 grb 6 PSP CC 35 CV3 grb 6 PSP 5 CC 4 CV3 grb 6 PSP 3 CC 4 CV3 grb 6 PSP 4 CC 4 CV3 grb 6 PSP 5 CC 4 CV3 grb 6 PSP 63 CC 4 CV3 grb 6 PSP 8 K8845 T83 D86989 N8748 E86783 A86986 Z86985 Y86984 X86983 W8698 D 6 GB 35 C P D 6 GB 35 C P D 6 GB 35 C6 P D 6 GB 35 C P D 6 GB 35 C5 P D 6 GB 4 C3 P D 6 GB 4 C4 P D 6 GB 4 C5 P D 6 GB 4 C63 P D 6 GB 4 C8 P Pack: piece SCDC6 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 gr Blades size 6-35 to 4 V DC grb-grd from to 8 A Electrical characteristics DC applications data Peak arc voltage vs. working voltage 9 8 7 6 5 4 3 4 L/R (ms) 8 3 3 36 Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 36 V with breaking capacity of 3 ka Time vs. current characteristics 5 3 : 35 V grb 4 : 4 V grb 5 : 4 V grd 4 4 44 48 8 6 4 Um(V) 3 4 5 : L/R = 3 ms-35-4 V grb : L/R = 5 ms 4 V grd Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) 4 3 6 5 3 4 5 63 8 grb a= 3 A=.6 B=.5 B=.6 Cf3=.8 ± 8% tolerance for mean pre-arcing current - - -3-4 3 4 Above: Curves indicate, for each rated current, the pre-arcing time vs. the R.M.S. pre-arcing current. /4 SCDC6

Sizes 6-6 - x6 gr Brackets size 6-4 V DC grb-grd from to 8 A Dimensions 86.5 5 3 9 376 394 46 74 74 6 8 ø3 Weight: 3,6 g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog 6 5 6 6 5 8 @ 4 V DC 3 ka L/R = 3 ms @ 4 V DC 3 ka L/R = 5 ms 55.6 7.4 84.8 58 76.5 95 8.8 3. 53.6 4 74 98 CC 4 grb 6 QF CC 4 grb 6 QF 5 CC 4 grb 6 QF 6 CC 4 grd 6 QF 6 CC 4 grd 6 QF CC 4 grd 6 QF 5 CC 4 grd 6 QF 8 V86958 W86959 X8696 E75766 F75767 G75768 H75769 D6GB4CQF D6GB4C5QF D6GB4C6QF D6GD4C6QF D6GD4CQF D6GD4C5QF D6GD4C8QF Pack: piece Microswitch MC R 3E -5NBS Ref. : J35 SCDC6 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 gr Brackets size 6-4 V DC grb-grd from to 8 A Electrical characteristics DC applications data L/R (ms) Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 36 V with breaking capacity of 3 ka Time vs. current characteristics t (s) 4 3 9 8 7 6 5 4 3 4 5 6 8 3 36 4 : 4 V grb 5 : 4 V grd 4 5 4 44 48 a= 3 A=.6 B=.5 B=.6 Cf3=.8 grb t (s) 4 3 8 6 4 Peak arc voltage vs. working voltage Um(V) : L/R = 3 ms 4 V grb : L/R = 5 ms 4 V grd Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 6 5 8 3 4 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 grd - - - - -3-3 -4 /4 3 4 5 Above, left and right: Curves indicate, for each rated current, prearcing time vs. R.M.S. pre-arcing current -4 SCDC63 3 4 5 ± % tolerance for mean pre-arcing current

Sizes 6-6 - x6 gr Brackets size x3-4 V DC grb-grd from to 56 A Dimensions 77 49 9 83.5 6 83.5 9 376 394 46 6 74,5 6 8 ø3 Weight: 765 g Main Characteristics Size Current I N ( A ) Breaking Capacity Watts loss.8 I N I N (W) (W) Ref. Catalog x6 5 35 4 5 56 @ 4 V DC 3 ka L/R = 3 ms @ 4 V DC 3 ka L/R = 5 ms 9 38 6 53 9 6 54 3 8 348 396 CC 4 grb x6 QF M CC 4 grb x6 QF 5M CC 4 grd x6 QF 35M CC 4 grd x6 QF 4M CC 4 grd x6 QF 5M CC 4 grd x6 QF 56M R86955 S86956 J7577 K7577 L7577 M75773 D6GB4CQF D6GB4C5QF D6GD4C35QF D6GD4C4QF D6GD4C5QF D6GD4C56QF Pack: piece Microswitch MC R 3E -5NBS Ref. : J35 SCDC64 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 gr Brackets size x3-4 V DC grb-grd from to 56 A Electrical characteristics DC applications data L/R (ms) Above: Curves indicate maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 36 V with breaking capacity of 3 ka Time vs. current characteristics t (s) 4 3 9 8 7 6 5 4 3 4 8 5 3 36 4 : 4 V grb 5 : 4 V grd 5 4 4 44 48 a= 3 A=.6 B=.5 B=.6 Cf3=.8 grb t (s) 4 3 8 6 4 Peak arc voltage vs. working voltage Um(V) : L/R = 3 ms 4 V grb : L/R = 5 ms 4 V grd Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 35 4 5 56 3 4 5 a= 3 A=.6 B=.5 B=.6 Cf3=.8 grd - - - - -3-3 -4 /4 3 4 5 Above, left and right: Curves indicate, for each rated current, prearcing time vs. R.M.S. pre-arcing current -4 SCDC65 3 4 5 ± % tolerance for mean pre-arcing current

Sizes 6-6 - x6 SR Brackets size 6-35 to 4 V DC 35-4 VDC SRB from to 3 A Dimensions 9 3 365 394 46 59.5 63 48 58 38 9 Weight: 9 kg 3 Main Characteristics Size Current I N ( A ) Breaking capacity Watts loss.8 I N I N Ref. Catalog 6 6 5 3 under 35 V = 6 ka L/R = 5 ms under 4 V: 6 ka L/R = 5 ms 5.5 8..5 3.3 6.5 8 3 9 36 CC 35 SRB 6 QF CC 35 SRB 6 QF 6 CC 4 SRB 6 QF CC 4 SRB 6 QF 5 CC 4 SRB 6 QF 3 E8945 F8946 G86946 H86947 J86948 D6SB35CQF D6SB35C6QF D6SB4CQF D6SB4C5QF D6SB4C3QF Pack: piece Microswitch MC R 3E -5NBS Ref. : J35 SCDC66 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 SR Brackets size 6-35 to 4 V DC SRB from to 3 A Size 6 Electrical characteristics DC applications data Peak arc voltage vs. working voltage Um(V) 8 6 L/R (ms) 4 V SRE 8 6 4 4 8 3 36 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 38 V with breaking capacity of 5 ka Time vs. current characteristics 4 4 3 : L/R = 5 ms 4 V SRE : L/R = 45 ms 4 V SRE 4 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage t (s) 6 5 3 4 3 C C' a= 3 A=.6 B=.3 B=.6 Cf3=.8 C C' a= 3 A=.6 B=.3 B=.6 Cf3=.8 C C' a= 3 A=.6 B=.3 B=.6 Cf3=.8 - - -3-4 3 3 4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC67

Sizes 6-6 - x6 SR Brackets size 6-35 to 4 V DC 4-4 V DC SRE from 4 to 5 A Dimensions 9 3 365 394 46 47.5 63 48 58 38 9 Weight: 9 g 3 Main Characteristics Size 6 Current I N ( A ) 4 5 63 8 5 5 Breaking Capacity @ 4 V DC 6 ka L/R = 5 ms @ 4 V DC 6 ka L/R = 5 ms Watts loss.8 I N I N (W) (W) 5 5 57 65 7 75 78 3 4 8 4 47 55 Max. I t @ 35 V L/R = 5 ms L/R = 45 ms (A S) (A S) 48 5 35 8 65 3 85 8 35 6 35 8 55 CC 4 SRE 6 QF 4 CC 4 SRE 6 QF 5 CC 4 SRE 6 QF 63 CC 4 SRE 6 QF 8 CC 4 SRE 6 QF CC 4 SRE 6 QF 5 CC 4 SRE 6 QF 5 Ref. C7949 D7949 E7949 F79493 G79494 H79495 V79667 Catalog D6SE4C4QF D6SE4C5QF D6SE4C63QF D6SE4C8QF D6SE4CQF D6SE4C5QF D6SE4C5QF Microswitch MC R -5NBS Ref. : J35 Pack: piece SCDC68 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 SR Brackets size 6-35 to 4 V DC 4-4 V DC SRE from 4 to 5 A Electrical characteristics DC applications data Peak arc voltage vs. working voltage Um(V) 8 6 L/R (ms) 4 V SRE 8 6 4 4 8 3 36 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 38 V with breaking capacity of 5 ka Time vs. current characteristics 4 4 3 : L/R = 5 ms 4 V SRE : L/R = 45 ms 4 V SRE 4 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 4 5 63 5 8 5 4 3 C C' a= 3 A=.6 B=.5 B=.6 Cf3=.8 C a= 3 A=.6 B=.5 B=.6 Cf3=.8 C a= 3 A=.6 B=.5 B=.6 Cf3=.8 C' C' - - -3-4 3 3 4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC69

Sizes 6-6 - x6 SR Bracket size 6-4 V DC SRF-SRH from to 375 A Dimensions 86.5 5 3 9 376 394 46 74 74 6 8 ø3 Weight: 356 g Main Characteristics Size Current I N ( A ) 6 5 35 375 Breaking capacity @ 4 V DC 6 ka L/R = 5 ms Watts loss.8 I N I N (W) (W) 9 8 47 8 3 45 8 Max. I t @ 35 V L/R = 5 ms L/R = 45 ms (A S) (A S) 45 95 8 8 375 35 CC 4 SRF 6 QF CC 4 SRF 6 QF 5 CC 4 SRF 6 QF 35 CC 4 SRH 6 QF 375 Ref. J79496 K79497 L79498 H76643 Catalog D6SF4CQF D6SF4C5QF D6SF4C35QF D6SH4C375QF Pack: piece Microswitch MC R 3E -5NBS Ref. : J35 SCDC7 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 SR Bracket size 6-4 V DC SRF-SRH from to 375 A Electrical characteristics DC applications data Peak arc voltage vs. working voltage Um(V) L/R (ms) 4 V SRF-SRH 8 8 6 6 4 4 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 3,8 V with breaking capacity of 5 ka Time vs. current characteristics t(s) 8 3 36 4 4 t(s) : L/R = 5 ms 4 V SRF-SRH : L/R = 45 ms 4 V SRF-SRH Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 5 35 375 3 4 4 3 C a= 3 A=.6 B=.5 B=.6 Cf3=.8 4 3 C a= 3 A=.6 B=.5 B=.6 Cf3=.8 C' C' - - - - -3-3 -4 3 4-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC7

Sizes 6-6 - x6 SR Brackets size x6-4 V DC SRF-SRH from 4 to 75 A Dimensions 77 49 83.5 6 83.5 9 376 394 46 6 74,5 6 8 ø3 Weight: 77 g Main Characteristics Size Current I N ( A ) x6 4 5 63 75 Breaking capacity @ 4 V DC 6 ka L/R = 5 ms Watts loss.8 I N I N (W) (W) 5 56 7 3 48 487 55 59 Max. I t @ 35 V L/R = 5 ms L/R = 45 ms (A S) (A S) 8 4 88 78 3 7 5 3 CC 4 SRF 6 QF 4 CC 4 SRF 6 QF 5 CC 4 SRF 6 QF 63 CC 4 SRH 6 QF 75 Ref. M79499 N795 H7954 N7843 Catalog D6SF4C4QF D6SF4C5QF D6SF4C63QF D6SH4C75QF Pack: piece Microswitch MC R 3E -5NBS Ref. : J35 SCDC7 /4

Protistor DC fuses Protistor DC fuses Sizes 6-6 - x6 SR Brackets size 6-4 V DC SRF-SRH from 4 to 75 A Size x6 Electrical characteristics DC applications data Peak arc voltage vs. working voltage Um(V) L/R (ms) 4 V SRF-SRH 8 8 6 6 4 4 Above: Curve indicates maximum permissible value of time constant L/R as a function of DC working voltage Max. AC voltage (5/6 Hz): 3,8 V with breaking capacity of 5 ka Time vs. current characteristics t(s) 8 3 36 4 4 t(s) 3 : L/R = 5 ms 4 V SRF-SRH : L/R = 45 ms 4 V SRF-SRH 4 Above: Curves indicate for various time constants L/R the peak arc voltage which may appear across fuse terminals, vs. DC working voltage 4 3 4 5 63 C a= 3 A=.6 B=.5 B=.6 Cf3=.8 4 3 75 C a= 3 A=.6 B=.5 B=.6 Cf3=.8 C' C' - - - - -3-3 -4 3 4-4 3 4 Above: Curves indicate, for each rated current, pre-arcing time vs. R.M.S. pre-arcing current /4 SCDC73

Microswitches & metric Studs Microswitches for other square-body Protistor REMOTE SIGNALING SYSTEMS FOR FITTING ON FERRAZ SHAWMUT FUSES EQUIPED WITH MICROSWITCH SUPPORT: All square-body sizes AC 44 / 8X / 9X / X / 7X / X / 3X and DC 7X / X / 7X / 3X / 6X PERMANENT INDICATION OF FUSE STATE: - CONDUCTIVE - BLOWN MANUAL RESETTING STANDARD AND LOW ELECTRICAL LEVEL WITH DIFFERENT INSULATION LEVELS VAPOR AND WATER TIGHT TYPE FOR USE IN CORROSIVE ATMOSPHERE Main Characteristics Type Standard Low level Watertight IP 5 MC3E -5N MCR3E -5N MC3E -5NBS MC3E -9NBS MCR3E -5NBS MCR3E -9NBS MCR3E -5NBS MCR3E -9NBS MC3E -5NET MCR3E -5NET MCR3E -5NET AC or DC Insulation voltage Ui (V) 5V 5 V V 6 V 5 V V 6 V AC voltage withstand test ( * ) 5 kv kv 5 kv kv () 3 kv () 4 kv () 6 kv () 3 kv (3) kv kv () 4 kv () Impulse voltage test Uimp,/5 µs ( ** ) kv 3 kv kv 3 kv 4 kv 6 kv 3 kv 4 kv Positive ope min.voltage /min.current V 5 ma V ma V ma Current 5 A 3 A 3 A Interrupting Current Non-inductive circuit Inductive circuit: L/R = 5ms 3V V 5V 3V V 5V 5/6 Hz A A 7 A 6 A DC 5 A.5 A,6 A,3 A 5/6 Hz DC 5 Hz DC 3 A 3 A 3 A A A A 3 A.5 A,5A 3 A, A. A 3 A 3 A A A.5 A, A Catalog ing system: MC3E -5 single pole microswitch - MC3E -9 double pole microswitch - MCR, MCR reinforced insulation microswitch. * Between power circuit and microswitch terminals as per IEC 6 and 694 and NFC 64 (5/6 Hz min duration in dry air). ** Between power circuit and microswitch terminals Uimp: impulse voltage according to IEC 947-. *** Between power circuit and microswitch terminals () fitting sizes 44-7 - 7-7 - 73-83 - 84 fuses. () fitting sizes 9-9 - 93-94 - - - - 3-4 fuses. (3) fitting sizes 7-7 - 73-74 - - 3-3 - 3-6 - 6 fuses. SCDC74 /4

Protistor DC fuses Protistor DC fuses Microswitches & metric Studs Microswitches for other square-body Protistor Remote signaling with 5 V AC/DC insulation voltage Quantity of NO-NC separated circuits Contact standard low level low level watertight MC3E -5N MC3E -5NBS MC3E -9NBS MC3E -5NET Ref. D3 E3 F3 L37 Weight (g) 39.5 39.5 45.7 4. Pack. () 3 3 3 3 Catalog MC3E-5N MC3E-5NBS MC3E-9NBS MC3E-5N ETANCHE Remote signaling with insulation voltage up to V AC/DC Quantity of NO-NC separated circuits Contact standard low level low level watertight MCR3E -5N MCR3E -5NBS MCR3E -9NBS MCR3E -5NET Ref. G33 P33 H34 Q33 Weight (g) 5.7 5.7 58. 5.5 Pack. () Catalog MCR3E-5N MCR3E-5NBS MCR3E-9NBS MCR3E-5N ETANCHE Remote signaling with insulation voltage up to 6 V AC/DC Quantity of NO-NC separated circuits Contact low level MCR3E -5NBS watertight MCR3E -5NET low level MCR3E -9NBS Ref. J35 N39 K36 Weight (g) 64. 64.8 7.3 Pack. () Catalog MCR3E-5NBS MCR3E-5NET MCR3E-9NBS Electrical diagram of each microswitch circuit NOTE (): The 6.4 dimension is the same with or separated circuits NO-NC. Non-blown fluse Microswitch ON Blown fluse Microswitch OFF Tests with sine vibrations carried out at ambient with scanning of the three main holder axes. Spectrum: st segment ( to 6 Hz) constant trip x = 5 mm peak. nd segment (6 to 5 Hz) constant acceleration g = 5 g peak. Exponential scanning speed : octave per minute. Duration: hours per axis. All of these signalling systems are hand resettable and fitted with silverplated 3-terminal microswitch C, NO and NC. The C terminal is on the top and connection is made via 6.35 mm clips except for watertight models whose clips are 4.8 mm wide. /4 SCDC75

Microswitches & metric Studs Metric-Studs Metric studs for threaded terminal fuses Type and fuse size Ref. Unit weight (g) Pack. Catalog Sizes and HC stud pair M8x3 & M8x35 S988 3 6 pairs STU M8x3 M8x35 Size HC stud pair Mx3 & Mx5 T988 4 6 pairs STU Mx3 Mx5 Size 3 HC stud pair Mx35 & Mx5 V9883 6 6 pairs STU Mx35 Mx5 Size HC stud pair Mx5 W9884 45 6 pairs STU Mx5 Size 3 HC stud pair Mx5 X9885 45 6 pairs STU Mx5 We recommend the use of studs, whose quality is suited to all FERRAZ SHAWMUT square-body fuses with terminals Stud mounting Torque type Stud type Maximum stud tightning torque (Nm) () Maximum nut tightning torque (Nm) () Balanced torque M8x3 & M8x35 Mx3 & Mx5 Mx35 & Mx5 5 5 3.5 6 46 Balanced torque M8x3 & M8x35 Mx3 & Mx5 Mx35 & Mx5 5 5 3.5 6 46 Unbalanced torque M8x3 & M8x35 Mx3 & Mx5 Mx35 & Mx5 5 5 3.5 6 46 () Factory limit on torque at C ambient: +, -Nm; except on 46Nm value (+, -4Nm) SCDC76 /4