Ultra Rapid Semiconductor Protection Fuses
|
|
|
- Jasmin Boyd
- 9 years ago
- Views:
Transcription
1 Product Brief Ultra Rapid Semiconductor Protection Fuses October 2012 Issue 1 Whatever your need, IXYS UK can provide the protection you require for your design With a reputation as one of the world leading manufacturers of power semiconductor devices, IXYS UK is renowned for high quality and class leading research, development, manufacture and marketing of high power silicon products. This brochure details the range of ultra rapid semiconductor protection fuses available for the power electronics industry from IXYS UK, specifically designed to provide protection for power semiconductors against circuit faults and to isolate failed devices. Utilising proven advanced technology, our fuses provide the performance and characteristics necessary to meet the levels of protection required in the onerous circuit conditions encountered in today s and tomorrow s power conversion equipment. The IXYS UK range of fuses offers fast acting, ultra rapid protection against device rupture, external short circuits, destructive energy let through and excessive peak currents. Applications Protection of rectifiers, inverters, DC drives, UPS systems, reduced voltage motor starters and other equipment in globally accepted applications These fuses are produced using proven, advanced technology to international standards. The majority of the IXYS UK range has UL recognition. Product range PSC (Prospective short circuit) square body fuses o American standard, square body o French standard, European square body o German standard, European square body British standard BS88 fuses DIN80 standard fuses French cylindrical fuses Associated microswitches Associated fuse holders
2 PSC Square body fuses Our PSC square body fuse links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. The 690/700V square body fuse links are available in 4 different body sizes, each having seven worldwide acceptable mounting styles. The 1250/1300V square body fuse links are available in 4 different body sizes with four mounting styles. Our PSC fuses have been engineered to provide state of the art protection for SCR s, diodes, thyristors, GTO s and IGBT s. All fuse links are equipped with a low voltage trip indicator. This indicator can operate a field mountable microswitch, also available from IXYS UK, which is easily mounted directly onto the fuse even while in service. Extremely fast acting Current limiting Very low I 2 t Worldwide acceptability Superior cycling ability Choice of mounting styles Broad range of current ratings in a given body size IEC compliance for worldwide semiconductor applications
3 North American mounting style Fuse Type: Part Number Voltage Range (V) Current Range (A) Body size Outline V End Contact V Blade Contact V Blade Contact V End Contact V Blade Contact 070US0UxxxxB US1UxxxxB US2UxxxxB US3UxxxxB US0BxxxxB US1BxxxxB US2BxxxxB US3BxxxxB US0DxxxxB US1DxxxxB US2DxxxxB US3DxxxxB US0UxxxxB US1UxxxxB US2UxxxxB US3UxxxxB US0DxxxxB US1DxxxxB US2DxxxxB US3DxxxxB F1 F2 F2 F1 F2
4 Outline F1 Size A B C D d E G P /16" x /16" x /8" x /2" x Outline F2 Size A B C D E1 E2 H J K L e USxB USxB USxB USxB USxD USxD USxD USxD
5 European mounting style Fuse Type: Part Number Voltage Range (V) Current Range (A) Body Size Outline (690)V End Contact 660(690)V Blade Contact V End Contact 069UR0SxxxxB UR1SxxxxB UR2SxxxxB UR3SxxxxB UF0AxxxxB UF1AxxxxB UF2AxxxxB UF3AxxxxB UR0SxxxxB UR1SxxxxB UR2SxxxxB UR3SxxxxB F3 F4 F3 Size A B C D d E G M N P M M M M Size A B C D E F H J K L e
6 German mounting style Fuse Type: Part Number Voltage Range (V) Current Range (A) Body Size Outline DIN (690)V Blade Contact DIN (690)V Blade Contact DIN V Blade Contact NR Size 000 & 00 Knife Blade Contact NH Size 000, 00 & 0 Knife Blade Contact 069UR0AxxxxB UR1AxxxxB UR2AxxxxB UR3AxxxxB UR0DxxxxB UR1DxxxxB UR2DxxxxB F25 069UR3DxxxxB UR0DxxxxB UR1DxxxxB UR2DxxxxB UR3DxxxxB NRCKxxxxF F26 066NRDKxxxxF F27 069NHCKxxxxF NHDKxxxxF NH0KxxxxF NH1KxxxxF F28 069NH2KxxxxF NH3KxxxxF Outline F25 Size A B C D H J L e DIN 80 Size DIN 80 Size DIN 80 Size DIN 80 Size DIN 110 Size DIN 110 Size DIN 110 Size DIN 110 Size
7 Outline F26 Outline F27 Outline F28 Size A B C H L M N P R T Product Brief Ultra Rapid Semiconductor Protection Fuses
8 European Semiconductor Fuses British standard BS88 These are extremely high interrupting fuses for the protection of power semiconductors as per IEC and They have voltage ratings up to 690V complying with IEC, DIN and VDE standards and have exceptionally low I2t power losses as well as a non magnetic construction. They also include a highly reliable low voltage indicator system and are UL recognised. They have increased technical performance, higher ratings and a reduced volume and weight. Extremely high interrupting rate Protection of power semiconductors as per IEC standard V rating as per IEC 33 Connections as per DIN 43653/00C These fuses are UL recognised All models include integrated trip indicator Fuse Type: Part Number Voltage Range (V) Current Range (A) Diameter (mm) Outline xlcw F5 xlew F6 xlewi F7 BS88 250V xlmw F8 xlmwi F9 xlmmw F10 xlmwwi F11 xcw F12 xew F13 BS88 660V 690V xewi F14 xmw F15 xmmw F16 xmmwi F17 BS88 660V Twin BS88 660V Size 000 xeew 070BQCLxxxxN F18 F20 xeewi 070BQCLxxxxI F19 F21 F5 xlcw F6 xlew F7 xlewi F8 xlmw
9 F9 xlmwi F10 xlmmw F11 xlmmwi F12 xcw F13 xew F14 xewi F15 xmw F16 xmmw
10 F17 xmmwi F18 xeew F19 xeewi F20 070BQCLxxxxN F21 070BQCLxxxxI
11 European Semiconductor Fuses DIN80 standard OPTIMAL PROTECTION OF POWER EQUIPMENT Thanks to recent technological developments, IXYS UK can bring you this range of protestor fuse, capable of clearing all types of overloads, from low multiples of current ratings up to very high short circuit currents. Enhanced performance enables these fuses to provide solutions to many previously unsolved problems in power electronics: protection of cables without the use of additional components, protection of equipment from fire hazards, selective coordination of different fuses within a single power distribution installation. Extremely high interrupting rate Protection of power semiconductors as per IEC standard V rating as per IEC 33 Connections as per DIN 43653/00C These fuses are UL recognised Fuse Type: Part Number Voltage Range (V) Current Range (A) Body Size Outline DIN80 Size 000 DIN80 Size GQCAxxxxF F23 070GQCAxxxxN F22 070GTCAxxxxF F24 070GGCAxxxxF F23 070GGCAxxxxN F22 070GSCAxxxxF F24 069GSDAxxxxF F24 069GUDAxxxxF F24 Outline F22 Outline F23 Outline F24
12 French Cylindrical Fuses Extremely high interrupting rate Protection of power semiconductors as per IEC standard V rating as per IEC 33 Connections as per DIN 43653/00C These fuses are UL recognised Fuse Type: Ferrule Fuses Part Number Voltage Range (V) Current Range (A) F070AxxxN F070BxxxN F070BxxxS F070CxxxN F070CxxxS F070AxxxN F070BxxxN F070CxxxN F070BxxxS F070CxxxS
13 Microswitches IXYS UK can offer a range of microswitches to suit our American square bodied fuses, European square bodied fuses, BS88 round body fuses and BS88 square body fuses Microswitch system: MS 3V 1 Fuse sizes: 0, 1, 2, 3 Indication style: MS 3V 1 5 = Standard NO NC MS 3V 1 5 BS = Low Level NO NC MS 3V 1 5 ET = Low Level NO NC IP 50 (9) MS 3V 1 9 BS = Low Level NO NC Part number AC Insulation Voltage Rating *** (V) Positive Operating Voltage/Current (V/mA) Current Rating (A) Current (A) Interrupting Rating (A) Non inductive circuit Inductive Circuit: L/R = 25ms 30V 110V 250V 30V 110V 250V AC Voltage Withstand * (kv) Impulse Voltage test V imp 1.2/50µs ** (kv) Fire Class according to UL 94 MS 3V 1 5 MS 3V 1 5 BS MS 3V 1 5 ET MS 3V 1 9 BS /50 10/10 10/10 10/ AC 50/60Hz DC AC 50/60Hz DC AC 50/60Hz DC AC 50/60Hz DC H.B. Microswitch system: MS 7V 1 Fuse sizes: 0, 1, 2, 3 Indication style: MS 7V 1 5 = Standard NO NC MS 7V 1 5 BS = Low Level NO NC MS 7V 1 5 ET = Low Level NO NC IP 50 (9) MS 7V 1 9 BS = Low Level NO NC Part number MS 7V 1 5 MS 7V 1 5 BS AC Insulation Voltage Rating *** (V) 1500 Positive Operating Voltage/Current (V/mA) Current Rating (A) 20/ /10 3 MS 7V 1 5 ET 10/10 3 MS 7V 1 9 BS 10/10 3 Current (A) Interrupting Rating (A) Non inductive circuit Inductive Circuit: L/R = 25ms 30V 110V 250V 30V 110V 250V AC Voltage Withstand * (kv) Impulse Voltage test V imp 1.2/50µs ** (kv) AC 50/60Hz DC AC 50/60Hz DC AC 50/60Hz DC AC 50/60Hz DC Fire Class according to UL 94 H.B.
14 Microswitch system: MS 4L 2 Fuse sizes: 0, 1, 2, 3 Indication style: MS 4L 2 5 B2 = Standard NO NC MS 4L 2 5 B6 = Low Level NO NC Part number MS 4L 2 5 B2+PRES AC Insulation Voltage Rating *** (V) 1000 Positive Operating Voltage/Current (V/mA) Current Rating (A) 20/100 5 MS 4L 2 5 B6+PRES 20/50 10 Current (A) Interrupting Rating (A) Non inductive circuit Inductive Circuit: L/R = 25ms 30V 110V 250V 30V 110V 250V AC Voltage Withstand * (kv) Impulse Voltage test V imp 1.2/50µs ** (kv) AC 50/60Hz DC AC 50/60Hz DC Fire Class according to UL 94 VO Microswitch system: MC 6.3 GR 2.5 N Fuse sizes: 0, 1, 2, 3 Indication style: For BS88 4 w/separate blown fuse trip indicators Part number MC 6.3 GR 2 5 N AC Insulation Voltage Rating *** (V) Positive Operating Voltage/Current (V/mA) Current Rating (A) Current (A) Interrupting Rating (A) Non inductive circuit Inductive Circuit: L/R = 25ms 30V 110V 250V 30V 110V 250V AC Voltage Withstand * (kv) Impulse Voltage test V imp 1.2/50µs ** (kv) Fire Class according to UL 94 AC 50/60Hz / H.B. DC Microswitch system: MC/MCR3E 1 5 N Fuse sizes: 0, 1, 2, 3 Indication style: Single pole microswitch for permanent indication of fuse state; conductive or blown Part number AC Insulation Voltage Rating *** (V) Positive Operating Voltage/Current (V/mA) Current Rating (A) Current (A) Interrupting Rating (A) Non inductive circuit Inductive Circuit: L/R = 25ms 30V 110V 250V 30V 110V 250V AC Voltage Withstand * (kv) Impulse Voltage test V imp 1.2/50µs ** (kv) MC3E 1.5 N /50 5 AC 50/60Hz DC MCR3E 1 5N /50 5 AC 50/60Hz DC Fire Class according to UL 94 H.B.
15 Fuseholders Standard version SI fuseholders for: Stud-type fuses Blade type fuses (SI00 and SI000) Bracket type fuses (SI DIN80 and DIN110 Part Number Fuse size Fuse Type Insulation Voltage (V) AC, 50/60Hz & DC Rated Current (A) Connection Outline SI 00 DIN80 00 DIN Blade FH1 SI 000 DIN DIN Blade FH2 SI DIN80 630A DIN Blade SI DIN A DIN Blade SI DIN A DIN Blade FH3 SI DIN A DIN Blade SI TT 30/31 30, 31 Stud type End SI TT 32/33 32, 33 Stud type End SI TT 70/71 70, 71 Stud type End FH4 SI TT 72/73 72, 73 Stud type End FH1 FH2 Outline Part Number A B C D E G L Fuse Sizes FH1 SI 00 DIN DIN 80 FH2 SI 000 DIN DIN80
16 Outline Part Number a e1 b c Fuse Sizes FH3 SI DIN80 630A SI DIN A SI DIN A SI DIN A DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN DIN110 IXYS UK Westcode Ltd s BS EN ISO9001 quality system is registered by BSI Langley Park Way Chippenham, SN15 1GE United Kingdom Tel: +44 (0) Fax: +44 (0) E mail: [email protected] Product Brief Ultra Rapid Semiconductor Protection Fuses Edisonstr. 15 D Lampertheim Germany Tel: +49 (0) Fax: +44 (0) E mail: [email protected] We are supported by a global network of local offices, representatives and distributors. Please visit our website for more information
PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES
PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available
BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
IXYS Solar Products. Product Brief. Harnessing energy has taken on a new dimension. Applications
Product Brief IXYS Solar Products November 2013 Issue 3 Harnessing energy has taken on a new dimension Over the past twelve years, IXYS UK has been actively involved in the renewable energy industry, providing
Type: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
British BS 88 Fuses. Introduction
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
BETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
High Speed Fuses. High Speed Fuses
Section Contents Page General Applications........................ 9-95 North American fuses & accessories............9-113 DFJ - High speed Class J fuse...................97 Square Body fuses & accessories............
Photovoltaic System Overcurrent Protection
Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and
IEC 60269 gg & am STANDARD LOW VOLTAGE FUSE
IEC 60269 gg & am STANDARD LOW VOLTAGE FUSE. INTRODUCTION 2. INTRODUCTION TO THE IEC 60269 STANDARD 3. COMPARISON OF THE TIME CURRENT CURVES OF DIFFERENT FUSE TYPES 3.. Comparison of IEC and UL fuses 3.2.
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
Fuse Selection Method Module 2. Date of the presentation
Fuse Selection Method Module 2 Date of the presentation Fuse Selection When selecting LV fuses certain important information must be known. 1.System Voltage This is the voltage of the system or distribution
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
Pluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Manual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Bourns Resistive Products
Bourns Resistive Products Diverse Requirements Drive Innovations to Pulse Resistors Introduction Countless circuits depend on the protection provided by one of the most fundamental types of passive components:
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Power transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
Thermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
Thermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
IXYS UK Westcode Ltd. currently has the following Employment Opportunities
IXYS UK Westcode Ltd is an Equal Opportunities employer, committed to the development of a skilled and quality focused workforce. IXYS UK Westcode Ltd is a registered NVQ Assessment Centre, and we encourage
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power
A sophisticated design for a demanding field. prima series
A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally
60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Catalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
E-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
A Practical Guide to Dielectric Testing
Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
Technicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
Contact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
IEC Connectors. Introduction
Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
Tape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current
MNS is Switchgear System Technical Overview
Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives
3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform
Principles of Adjustable Frequency Drives
What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable
1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
Bimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
E-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
DC Combiner box and AC solutions. Leadership in circuit protection
DC Combiner box and AC solutions Leadership in circuit protection Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability
Actuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
NEC Class 2 Power Circuits and Power Supplies
NEC Class 2 Power Circuits and Power Supplies Abstract: The NEC (National Electrical Code) is a North American standard, which can be regarded as a law in most of the North American states. Among others,
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
mpm DIN 43650 CONNECTORS
mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide
The complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
SMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
