NH DIN Dual Indication Fuse Links Class gg/gl, 690Vac, 2 to 800 Amps, Sizes 000 to 4 NH Series
|
|
- Mitchell George
- 7 years ago
- Views:
Transcription
1 Description: A range of Class gg/gl square bodied industrial fuse links for a variety of applications. Packaging: MOQ: 3 (size 000 to 3) MOQ: 1 (size 4) Catalogue Symbol: Class of Operation: (amp)nhg(size)b-690 gg/gl Fuse Size: 000 to 4 Fuse Holders: Fuse Bases: SD*-D single-pole, TD*-D three-pole Fuse Rails-Vertical: BFR Fuse Switch Disconnectors-Vertical: BFD Fuse Switch Disconnectors-Horizontal: BFH * Select required size of fuse base Standards/Approvals: IEC and 2, DIN Part 1 and 3 Optional Microswitch: BVL50 and 170H0236 Technical Data: Sizes: 000 to 4 Rated Voltage: 690Vac* Rated Current: 2 to 800A Rated Breaking Capacity: 120kA** Operating Frequency: 45-62Hz Construction: - Steatite ceramic body - Corrosion resistant aluminium end plates - Corrosion resistant zinc plated plated screws - Silver-plated brass or copper contact blades Environmental 100% Recyclable (including packaging) RoHS Compliant Cadmium and lead free Features Low watts loss Reliable dual indicator system Metal gripping lugs * 160A size 00 rated at 660Vac ** 160A size 00 rated at 50kA BU-SB Form NH 690V gg/gl Page 1 of 9 Data Sheet
2 Dimensions (mm) Sizes 000 to 3 Size a1 a2 (max) a3 a4 b1 c1 c2 d1 e1 (max) e2 (max) e3 e4 f1 (max) ± ±1.5 49± ± ± ± ±1.5 49± ± ± ± ±2.5 68± ± ± ± ±2.5 68± ± ± ± ±2.5 68± ± ± Size BU-SB Form NH 690V gg/gl Page 2 of 9 Data Sheet
3 Size 000, 2 to 63 Amps Size 000 Time-Current Characteristics Currents in Amps (A) Size 000 Technical Data I 2 t (A 2 s) 2NHG000B NHG000B NHG000B NHG000B NHG000B NHG000B NHG000B NHG000B NHG000B , NHG000B , NHG000B , NHG000B , BU-SB Form NH 690V gg/gl Page 3 of 9 Data Sheet
4 Size 00, 50 to 160 Amps Size 00 Time-Current Characteristics Size 00 Technical Data I 2 t (A 2 s) 50NHG00B , NHG00B , NHG00B ,000 54, NHG00B ,000 92, NHG00B , , NHG00B-660* , , * 160A: 50kA breaking capacity BU-SB Form NH 690V gg/gl Page 4 of 9 Data Sheet
5 Size 1, 50 to 250 Amps Size 1 Time-Current Characteristics Size 1 Technical Data I 2 t (A 2 s) 50NHG1B , NHG1B , NHG1B ,500 47, NHG1B , , NHG1B , , NHG1B , , NHG1B , , NHG1B , , NHG1B , , BU-SB Form NH 690V gg/gl Page 5 of 9 Data Sheet
6 Size 2, 200 to 315 Amps Size 2 Time-Current Characteristics Size 2 Technical Data I 2 t (A 2 s) 200NHG2B , , NHG2B , , NHG2B , , NHG2B , , BU-SB Form NH 690V gg/gl Page 6 of 9 Data Sheet
7 Size 3, 250 to 500 Amps Size 3 Time-Current Characteristics Size 3 Technical Data I 2 t (A 2 s) 250NHG3B , , NHG3B ,000 1,400, NHG3B ,000 1,650, NHG3B ,000 1,600, NHG3B ,000 1,700, NHG3B ,000 2,480, BU-SB Form NH 690V gg/gl Page 7 of 9 Data Sheet
8 Size 4, 630 to 800 Amps Size 4 Time-Current Characteristics Size 4 Technical Data I 2 t (A 2 s) 630NHG4B ,730,000 6,550, NHG4B ,300,000 11,000, BU-SB Form NH 690V gg/gl Page 8 of 9 Data Sheet
9 Cut-off Characteristics Peak Cut-Off Current (ka) RMS Symetrical Prospective Current (ka) The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications BU-SB Form NH 690V gg/gl Page 9 of 9 Data Sheet
Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable. Technical Data:
Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable Catalogue Symbol: Class of Operation: Fuse Size: NIT (amp rating) NET (amp rating) TIA (amp rating) TIS
More informationIEC and British Standard Fuses
IEC and British Standard Fuses Section Contents Page Application Data...7-8 CSA Type P and Type D fuses (CDS, CDN & PON)............................9 Tron HRC Form II Class C fuses (CGL Form II Class C)..........................
More informationPhotovoltaic System Overcurrent Protection
Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and
More informationHigh Speed Fuses. High Speed Fuses
Section Contents Page General Applications........................ 9-95 North American fuses & accessories............9-113 DFJ - High speed Class J fuse...................97 Square Body fuses & accessories............
More informationSolar Circuit Protection Application Guide. Complete and reliable solar circuit protection
Solar Circuit Protection Application Guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s Circuit Protection Solutions Complete and Reliable Circuit Protection for Photovoltaic
More informationBRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
More informationFuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
More informationSolar circuit protection application guide. Complete and reliable solar circuit protection
Solar circuit protection application guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s circuit protection solutions Complete and reliable circuit protection for photovoltaic
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationBritish BS 88 Fuses. Introduction
British BS 88 Introduction British BS 88 Contents Fuse Volts Amp Range Page 0-900 188-190 90-791-19 Accessories Indicator System & Fuse Bases 195 British BS 88 Fuse Ranges Amps Vac Vdc -900 0 150-710 90
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationW DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
More informationSWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
More informationDigital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester
Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More informationAC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models
TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual
More informationPSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES
PSC SQUARE BOY Ferraz Shawmut 690/700V PSC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse-links are available
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationSolid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection
More informationSOURIAU s discrete wire sealing
SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing
More informationSeries P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
More informationFuse Selection Method Module 2. Date of the presentation
Fuse Selection Method Module 2 Date of the presentation Fuse Selection When selecting LV fuses certain important information must be known. 1.System Voltage This is the voltage of the system or distribution
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationAutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationCEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61
FUSES Catalogue CEF 9 CEF-S 23 CEF-VT 27 CMF 31 WBP 39 WBT 47 BPS 61 INTRODUCTION The main function of current limiting fuses is to protect electrical apparatus, such as distribution transformers, motors
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More information3K Load-Break Switches The Program for Safety and Performance. sentric
3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break
More informationPhysical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C
M I/O Interconnect System 2.0 mm for IEEE 194 Wiremount Receptacle (Female) E206 Series Designed to mate to all M I/O Interconnect System 2.0 mm for IEEE 194 Boardmount Plugs Polarized to provide proper
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More informationUMEC International Corporation
UP1301A SERIES 130 Watt Open Frame Switchers Small Size 3*5*1.2(inches) Universal Input to 264 VAC Low Power Consumption Overvoltage Protection Continuous Short Circuit Protection Over Temperature Protection
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More information3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series
M Pin Strip Header Single and Dual Row.100,.25 /.18 Mating Length, &, Solder Tails 929 Series Stackable Gold, Matte Sn, or -Lead plating options High Temperature (PCT) plastic for Wave or IR soldering
More information3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series
M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series Stackable Tin Lead or gold plating available Solder stand-offs facilitate production wave soldering Board pin
More informationProblem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationhandbook, 2 columns handbook, halfpage 085 CS
FEATURES Polarized aluminium electrolytic capacitors, non-solid, self healing Extended voltage and capacitance range SMD-version, fully moulded, insulated Flexible terminals, reflow and wave solderable
More informationwww.jameco.com 1-800-831-4242
Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. SPECIFICATION CUSTOMER: JAMES DATE: 04.08.23 MODEL NO: DBU090030 DESIGNED
More informationKAM 25-32 A Lighting Busbar System KAP 40-63 A Plug-in Busbar Distribution System
2-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / E-LINE KX Compact Busbar Distribution System 63...63 A E-LINE KB Compact Busbar Distribution System 8...63 A E-LINE KO Plug-in
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationSolid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationAC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC
4L Series AC Line Rated Ceramic Disc Capacitors Class X, 76 V AC / Class Y, 5 V AC FEATURES Complies with IEC 6384-4, 4 th edition High reliability Radial leads High capacitance up to nf Singlelayer AC
More informationTop Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION
SPECIFICATION High Quality Switching Wallmount Adapter Interchangeable AC Plugs 90-264VAC Input 13.5W 9VDC 1.5A Output P/N: W090015HK-XP ** Specification Approval** This specification (total 11 pages including
More informationCCM05 SD, MMC & minisd
For one of the most common card formats, we offer various reading options in a small and sturdy packaging. This includes the smaller standard of the minisd, designed for the mobile communication needs.
More informationTerminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire
9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Miniature Standard Amperage Rating - CU Wire 115 amp. 115 amp. 175 amp. 175 amp. Amperage Rating - AL Wire 90 amp. 90 amp. 135 amp.
More informationZ-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com
CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH
More informationONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationTechnical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment
fischer Rugged Flash Drive New Rugged Solution for Safe Data Storage in Harsh Environment Headquarters Fischer Connectors SA Ch. du Glapin 20 1162 Saint-Prex Switzerland Phone +41 21 800 95 95 mail@fischerconnectors.ch
More informationCopper and Aluminum busbars
Copper and Aluminum busbars Two metals are currently used as conductors in electric panel boards: copper and aluminum In particular, when in need to define a power distribution inside an electric panel
More informationWood pellet and biomass system ceramic igniter
Wood pellet and biomass system ceramic igniter Specification Data Product name: Ceramic Igniter PSx-2-120-W Drawing number: IBA-HH020A Revised on: 2015.12.20 1. Application This engineering specification
More informationTC50 High Precision Power Thin Film chip resistors (RoHS compliant Halogen Free) Size 1206, 0805, 0603
WF2Q, WF08Q, WF06Q ±%, ±0.5%, ±0.25%, ±0.%, ±0.05% TC50 High Precision Power Thin Film chip resistors (RoHS compliant Halogen Free) Size 206, 0805, 0603 *Contents in this sheet are subject to change without
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationModel CS 64 Mini-DIN Cable and Adaptor
Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More information3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series
M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Ultra-low signal skew for high data rate transmission
More informationICON Server box installation manual Rev. 1.1
ICON Server box installation manual Rev. 1.1 Contents 1.0 About this manual... 3 2.0 Intended use... 3 2.1 European WEEE directive... 3 3.0 Installation and service instructions... 4 Server box overview...
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationLinkeo 19" freestanding cabinets
87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3
More informationSemiconductor (AC) fuses
14x51 & 22x58 URC / URD - 600 to 690 VAC EXTREMELY BREAKING CAPACITY RATING FUSES: PROTECTION OF POWER SEMI CONDUCTORS COMPLYING WITH IEC STANDARD 60269.1 AND 4 600-690 V AC VOLTAGE RATING ar-class ACCORDING
More informationSelector Switch Type 01
Selector Switch Type 0 Compact positions selector switch,000 switching cycles with up to.0 Ncm switching torque Gold plated contacts: micron Robust metal housing with metal shaft Optional IP front panel
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationMedium voltage products. Fuses
Medium voltage products Fuses Index Introduction... 3 Main definitions... 4 ABB HV Fuses with Temperature Control Unit... 5 General principles for fuse link selection... 6 CEF... 8 CEF-S... 16 CEF-VT...
More informationB MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
More informationHigh Speed Infrared Emitting Diode, 870 nm, GaAlAs Double Hetero
TSFF55 High Speed Infrared Emitting Diode, 87 nm, GaAlAs Double Hetero 26 DESCRIPTION TSFF55 is an infrared, 87 nm emitting diode in GaAlAs double hetero (DH) technology with high radiant power and high
More informationOptocoupler, Phototransistor Output, with Base Connection
4N25, 4N26, 4N27, 4N28 Optocoupler, Phototransistor Output, FEATURES A 6 B Isolation test voltage 5000 V RMS Interfaces with common logic families C 2 5 C Input-output coupling capacitance < pf NC 3 4
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationPCMC063T- Power Choke Coil
PCMC063T- Power Choke Coil Features Low loss realized with low DCR 100% lead (Pb) free, RoHS compliant High performance (Isat) realized by metal dust core Low profile: 12.6mm x 13.8mm x 5.0mm Capable of
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationRPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007
Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid
More informationMedium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationExample of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.
Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on
More informationRoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
More informationLightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS
LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS 1 st Edition 29 th November 2013 Table of content a. Disclaimer... 3 b. Introduction... 3 c. Summary check lists for components...
More informationSwitchboard system. NorLine 800
Switchboard system NorLine 800 NorLine 800 SWITCHBOARD SYSTEM 2 NorLine 800 Switchboard system Table of contents Subject Page Table of contents 2 Overview 2-3 NorLine 800 technical specifications 4 Structural
More informationHow To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationSurface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications
Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications ELECTRICAL SPECIFICATIONS X7R GENERAL SPECIFICATION Note Electrical characteristics at +25 C unless otherwise specified
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
More informationtype V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
More informationEMERGENCY EGRESS LIGHTING POWER SUPPLY PART NO. 5925-6 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST
EMERGENCY EGRESS LIGHTING POWER SUPPLY PART NO. WITH ILLUSTRATED PARTS LIST Initial Issue: June 16, 1995 33-51-80Page 1 May 20/2010 RECORD OF REVISIONS REV. NO. ISSUE DATE A 01-26-96 B 09-21-99 C 10-26-09
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More informationSealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationProtection from Short-circuit
Protection from Short-circuit Back-up Fuse-Link with ÜLA (controlled power dissipation) Test device for tripping device Special version with threat High-voltage Fuse-Link for voltage transformers (HSW)
More informationOutdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationIEC 60269 gg & am STANDARD LOW VOLTAGE FUSE
IEC 60269 gg & am STANDARD LOW VOLTAGE FUSE. INTRODUCTION 2. INTRODUCTION TO THE IEC 60269 STANDARD 3. COMPARISON OF THE TIME CURRENT CURVES OF DIFFERENT FUSE TYPES 3.. Comparison of IEC and UL fuses 3.2.
More information