GFC-L3 ADVANCED TECHNOLOGIES GFC-L3. Comfort. Ef ciency. Safety. Ecology. Energy Saving, Permanent Magnet Motor



Similar documents
PASSENGER ELEVATOR (COMPACT MACHINE ROOM SYSTEM) Series-IP/AP Version2

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM

S WORK CATALOGUE FAA29100H_BWC

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

Switch. Building technology for the real world.

freight elevators 2008 planning guide ThyssenKrupp Elevator Americas Business Unit

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

V1504 Vertical Platform Lift OWNER S MANUAL

Planning Information. Passenger and Freight Elevators.

Machine Room Less (MRL) Elevators. Evolution in elevator design.

Expertise in heavy loads. ThyssenKrupp freight elevators.

Roped Hydraulic Residential Elevator Specifications

Schindler 3100 Simple and practical. Our passenger elevator for small residential buildings really gets you moving.

V1504 Vertical Platform Lift OWNER S MANUAL

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

Schindler 3300 AP A remarkable style that suits the building. The machine room-less passenger elevator that unifies form and function.

MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY. KONE EcoSpace

Refined design Refined design to give consideration to health and the environment adds new value to the elevator.

Hospital Bed ElevatorS

Lift and Escalator Installations

ThyssenKrupp Company Name

LIFT CONTROL SYSTEMS CATALOGUE 2007

Interfacing Elevators with Fire Alarm and Sprinklers

LIFT CONTROL SYSTEMS CATALOGUE 2007

UBC Technical Guidelines Division Edition CONVEYING EQUIPMENT Page 1 of 1 INDEX. Section

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

OPTIONS Living Collection and Prime Series

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

Hydraulic Controllers, PHC, HS

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

Schindler 5500 Efficiency. Flexibility. Performance.

Recommendations to improve the safety of existing lifts

Automatic Door Selection Guide

LET OUR HYDRAULIC LIFTS HANDLE THE PRESSURE

Cooktop Low-Profile Ventilation Hoods

A1.5 Classroom Standards

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

KONE EN81-71 CAtegory 1. Vandal Resistant Lift

BLADE S-MAX Cabinet for Blade Server

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

OTIS. Lumina. LUMINA. We set out to meet your design expectations. Then we endeavoured to exceed them.

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Schindler 6400 NA A complete modernization solution for mid-rise elevators

MONORAIL. Scomi Rail THE REVOLUTION OF URBAN TRANSIT. A smooth ride quality. Higher passenger capacity. Energy efficiency. Lower operating costs.

DUOTOUR WITH SLIDING DOORS OPERATING MANUAL

MOOVO, BEAUTIFULLY PRACTICAL

Mechanical Engineering and Material Handling Aspects of NSDF

MODIFIED INDUSTRY STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS

Lödige Goods Passenger Lifts

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

TESTING AND COMMISSIONING PROCEDURE FOR LIFT, ESCALATOR AND PASSENGER CONVEYOR INSTALLATION GOVERNMENT BUILDINGS

At the completion of this guide you should be comfortable with the following:

Fire Pump Plan Review March 2010

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE

PLM series Permanent load lifting magnets

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT SUBMITTAL OF CONVEYANCE INSTALLATION/ALTERATION PLANS

RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles;

Product Data Sheets. Belt Conveyor System

Distribution Voltage Regulators

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

P.A.L. S SPECIFICATIONS

The Complete KASTO Program: Economic Sawing and Storing of Metal.

BROWACOM PRODUCTS. Our web-pages can be found from:

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Page 1. Description

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

The mechanics finish work on time today...

Understanding Emergency Power Off (EPO)

Standard Design TKLP Cab

Visual Tutorial Basic Edition 1. Visual. Basic Edition Tutorial.

GSM Home Alarm System User Manual.

ASSEMBLY MANUAL SE-4S35

Secondary Unit Substations

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Walking and Working Surface Checklist:

Customized Server Cabinets

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Shunt lock function 3066

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Architectural Planning Guide

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

HERNANDO COUNTY FIRE ALARM GUIDELINES

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

DEPARTMENT OF CORRECTIONS

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

I.S :2013 Fire Detection & Alarm Systems

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

LOS 2500 SUPER CEILING SENSOR. Installation Manual

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

LIFT CONTROL SYSTEMS CATALOGUE 2009

Electrical. This section applies to the design and installation of building power distribution systems.

Transcription:

ADVANCED TECHNOLOGIES Comfort Ef ciency Energy Saving, Permanent Magnet Motor freight elevator equipped with high efficient permanent magnet motor. Through the advanced technology of permanent magnet motor, brings more comfortable and quiet riding for the passengers. Moreover, it saves more electricity compared with the traditional worm gear driven traction machine. Variable Voltage Variable Frequency (VVVF) Control System The application of VVVF control to the freight elevator is a great breakthrough of technology. Not only does it provide smooth and steady operation, but also greatly improves the efficiency of energy utilization to achieve more energy saving performance. Safety Ecology ata et or it rti cial ntelligence an Frien ly Man Mac ine nter acing The elevator system configures with a data network. Developed using leading edge technology, it connects with microprocessors at each distributed modules through a serial transmission line. Each module is assigned appropriate intelligent features, resulting in a substantial improvement in man-machine interfacing. A mutual check function ensures further reliability and efficiency in data. More ser Frien ly erating Features To ensure the safety and smooth riding for both passengers and goods, the new series freight elevator employs more user friendly features. They have been strictly tested and simulated in the factory before delivery, thus the reliability is greatly improved and possibility of breaking down is reduced. Energy saving, permanent magnet motor. 1 2

CAR DESIGNS ENTRANCE DESIGNS Specification Car Type FCD-A FCD-B Lighting Fluorescent lighting through covers Fluorescent lighting through embed milky-white resin covers Ventilation equipment Diffuser Electric blower with slit vents Walls and doors Entrance columns Car wall protection plate Flooring Sill Painted steel sheet Stainless steel hairline (Opional) Stainless steel hairline Stainless steel hairline (for painted steel walls only) Steel checker plate with black paint Durable vinyl tile (Opional) Extruded hard aluminum (Capacity of 2,000kg or less) Steel plate with black paint (Capacity over 2,000kg) Specification Door frame Doors Sill Painted steel sheet Stainless steel hairline (Opional) Painted steel sheet Stainless steel hairline (Opional) Extruded hard aluminum (Capacity of 2,000kg or less) Steel plate with black paint (Capacity over 2,000kg) Detailed disposing of fan and lighting, plesae consult our local agents. 3 Elevator color shown is slightly different from actual tone. Elevator color shown is slightly different from actual tone. 4

FINISH COLORS AND PATTERNS FEATURES FOR PRODUCTS Durable Vinyl Tiles (For Car Flooring) FOR COMFORT, CONVENIENCE AND SAFETY False Call Canceling-Car Button Type (FCC-P) If the wrong car button is pressed, it can be canceled by quickly pressing the same button again twice. on- er ice to peci c Floors-Car Button Type (NS-CB) [Optional] To enhance security, service to specific floors can be disabled using the car operating panel. This function is automatically deactivated during emergency operation. Repeated Door-Close (RDC) Painted Finish (For Car Walls / Car Doors / Door Frames) Should an obstacle prevent the doors from closing, the doors will repeatedly open and close until the obstacle is cleared from the doorway. Extended Door-Open Button (DKO-TB) When the button inside a car is pressed, the doors will remain open longer to allow loading and unloading of baggage, a stretcher, etc. Door Load Detector (DLD) When excessive door load has been detected while opening or closing, the doors immediately reverse. Mitsubishi Emergency Landing Device (MELD) [Optional] Upon power failure, a car equipped with this function automatically moves and stops at the nearest floor using a rechargeable battery, and the doors open to ensure passenger safety. (Maximum allowable floor-to-floor distance is 10 meters.) (MELD is only applied bellow: 750~1000 kg ~105 m/min, 1500~2500 kg 45~105 m/min.) 5 Color shown is slightly different from actual tone. * See page 21-24 for details of other features. 6

SIGNAL FIXTURES Car Operating Panel Hall Position Indicators Hall Buttons Buttons accented with LED halo illumination Standard Optional Yellow-orange Yellow-orange White White Assembled into transom panel Tactile button : 1 Flat button : 2 Blue Tactile button : 3 Blue Flat button : 4 Specification Faceplate Stainless steel hairline (PIH-D417) Display panel Smoky gray plastic, matte surface Direction light and indicator Segment LED indicator (orange color when illuminated) Specification Faceplate Call button Respones light Metal-like resin faceplate (HBV1-A710) Stainless steel hairline (HBV1-C710) Micro stroke click button LED (Buttons accented with LED halo illumination) Tactile button : 5 Flat button : 6 Hall Position Indicators and Call Buttons Specification Faceplate Display panel Direction light and indicator Call button Respones light Stainless steel hairline Smoky gray plastic, matte surface Segment LED indicator Micro stroke click button LED (Buttons accented with LED halo illumination) Specification Faceplate Display panel Direction light and indicator Metal-like resin faceplate (PIV1-A710 / PIV1-A720) Stainless steel hairline (PIV1-C710 / PIV1-C720) Smoky gray plastic, matte surface (PIV1-C710 / PIV1-C720) Segment LED indicator Call button Micro stroke click button Respones light LED (Buttons accented with LED halo illumination) 7 Elevator color shown is slightly different from actual tone. Elevator color shown is slightly different from actual tone. 8

INSTALLATION DRAWINGS 750kg, 1000kg (,,105m/min) 1500kg~2500kg (45,,,105m/min) Y BB X AA Machine room height 100 (HM) Cinder Concrete finish Hoisting hook X AA Machine room height 100 (HM) Cinder Concrete finish Hoisting hook BM R2 R1 Vent. window CONTROL PANEL JJ Entrance width AM R4 R3 Power supply for lighting Traction machinery power supply Access door 750 kg = 1000 2000 1000 kg = 1200 2000 Ventilation fan 150 Total height (HT) Pit depth Travel (TR) Overhead (OH) (PD) Floor height Entrance height (HH) Top clearance Top clearance (HB) (TC) P1 P2 BM Y BB R1 R2 R3 Vent. window JJ Entrance width AM R4 R5 R6 Power supply for lighting Traction machinery power supply Access door 1200 2000 150 Total height (HT) Pit depth Travel (TR) Overhead (OH) (PD) Floor height Entrance height (HH) P2 P1 CONTROL PANEL Ventilation fan 9 * The above installation drawings ( 1:1 roping ) are only applicable for rated capacity 750~1000kg. * The above installation drawings ( 2:1 roping ) are only applicable for rated capacity 1500~2500kg. 10

SUPPLY SCOPE 750kg,1000kg (,,105m/min) 1500kg~2500kg (,105m/min) Rated capacity (kg) Door type Rated speed (m/min) Entrance width JJ Car internal (AA BB) Dimensions Minimum hoistway (X Y) Minimum machine room (AM BM) Reaction loads (kn) Machine room Pit R1 R2 R3 R4 P1 P2 Rated capacity (kg) Door type Rated speed (m/min) Entrance width JJ Car internal (AA BB) Dimensions Minimum hoistway (X Y) Minimum machine room (AM BM) Reaction loads (kn) Machine room Pit R1 R2 R3 R4 R5 R6 P1 P2 750 2S 75.2 66.2 1200 1500 2000 2300 2570 3000 4000 32.1 32.2 15.9 23.3 86.9 76.5 1500 2S 162.0 159.1 1700 2200 2400 3255 3105 4000 5100 44.8 39.7 33.6 49.5 13.7 5.7 105 1.8 171.7 105 102.4.2 102.6 89.4 2000 2S 184.0 148.5 1800 2200 2800 3280 3320 4300 5100 49.2 43.6 35.8 54.2 15.6 6.0 105 216.7 174.8 1000 2S 1500 1800 2200 2720 2720 3400 4400 41.4 45.5 21.7 32.2 113.7 98.5 105 134.0 116.1 2500 3S 251.6 171.7 2100 2500 3000 3530 3595 4500 5700 65.2 57.0 49.1 69.3 17.5 6.5 105 271.4 202.2 When CWT safety gear is required, please consult with the engineering section. When CWT safety gear is required, please consult with the engineering section. 1500kg~2500kg (45,m/min) Maximum Number Stops,Travel and Minimum Floor Height Rated capacity (kg) Door type 1500 2S 2000 2S 2500 3S Rated speed (m/min) Entrance width JJ Car internal (AA BB) Dimensions Minimum hoistway (X Y) Minimum machine room (AM BM) Reaction loads (kn) Machine room Pit R1 R2 R3 R4 R5 R6 P1 P2 45 132.0 111.5 1700 2200 2400 3150 3105 4000 5100 47.7 34.4 33.9 48.1 9.7 4.5 139.0 117.5 45 157.4 128.5 1800 2200 2800 3280 3320 4300 5100 50.6 44.1 37.9 57.1 15.5 6.2 165.2 135.3 45 202.7 165.6 2100 2500 3000 3530 3595 4500 5700 65.2 57.0 49.1 69.3 17.5 6.5 213.5 174.4 When CWT safety gear is required, please consult with the engineering section. Rated capacity (kg) 750~1000 1500 2000 2500 Rated speed (m/min) 105 45 105 45 105 45 105 Maximum number of stops 30 Maximum travel (m) 80 HH+700 11 12

SUPPLY SCOPE Vertical Dimensions Rated capacity (kg) 750 1000 1500 2000 2500 OH: Overhead PD: Pit depth TC: Top clearance HH: Enteance height HB: Car frame height HM: Machine room height Rated speed (m/min) OH PD TC 4650 1550 1450 4800 1800 10 105 5000 2100 1800 4650 1550 1450 4800 1800 10 105 5000 2100 1800 45 4450 1250 1250 4650 1550 1450 4800 1800 10 105 5000 2100 1800 45 4450 1250 1250 4650 1550 1450 4800 1800 10 105 5000 2100 1800 45 4850 1250 1250 5050 1550 1450 5200 1800 10 105 5400 2100 1800 When CWT safety gear is required, please consult with the engineering section. HH HB HM 2100 3200 2500 2100 3200 2650 2100 3200 2100 3200 2500 2650 2650 2950 2500 30 2950 Power Feeder Data Capacity (KG) Speed (m/min) Capacity of Power Supply (KVA) Breaker Current Rating in M/R (200V) (400V) 750 5 30A 15A 750 7 50A 30A 750 105 8 50A 30A 1000 7 40A 20A 1000 10 A 30A 1000 105 11 75A 40A 1500 45 8 50A 30A 1500 10 A 30A 1500 14 100A 50A 1500 105 16 100A 50A 2000 45 10 A 30A 2000 13 75A 40A 2000 19 125A A 2000 105 20 150A 75A 2500 45 12 75A 40A 2500 16 100A 50A 2500 23 150A 75A 2500 105 26 175A 100A NOTE: Freight elevators of less than 2500kg capacity can only be loaded by handtrucks with casters. Goods cannot be loaded by forklift. Please consult our local agents if you plan to use a forklift to load and unload goods with our traction-type freight elevators of 2500kg capacity. 13 14

ENTRANCE LAYOUT 2S Doors (E-102) (2-panel side sliding doors) 3S Doors (E-202) (3-panel side sliding doors) 2CO Doors (E-202) (4-panel center opening doors) 15 * For other door types and JD dimension, please contact our local agents for detail. 16

FEATURES Table of Features (Standard) Feature Description Feature Description Operation System Door Operation features (1C-2BC) 1 CAR Selective Collective Operational and Service Features (CCC) Car Call Canceling (OLH) Overload Holding Stop (SFL) Safe Landing The system consists of call buttons in the car, and a riser of up will respond to those car and hall calls that comply with its direction of system regards remaining calls in the other direction as mistakes and (DLD) Door Load Detector (DODA) Door Sensor Self-diagnosis (DOT) Automatic Door-open Time Adjustment (DSAC) Automatic Door Speed Control (RDC) Repeated Door-Close (ROHB) Reopen with Hall Button When excessive door load has been detected while opening or closing, the doors immediately reverse. Failure of non-contact door sensors is checked automatically, and if a problem is diagnosed, the door-close timing is delayed and the closing speed is reduced to maintain elevator service and ensure passenger safety. The time doors are open will automatically be adjusted, depending on whether the stop was called from the hall or the car, to allow smooth boarding of passengers or loading of baggage. monitored to adjust the door speed, thereby making the door speed Should an obstacle prevent the doors from closing, the doors will repeatedly open and close until the obstacle is removed. corresponding to the traveling direction of the car. (CFO-A) Car Fan Shut Off Automatic (SDE) Safety Door Edge Sensitive door edges detect passengers or objects during door closing. (CLO-A) Car Light Shut Off Automatic (FCC-A) False Call Canceling Automatic (IND) Independent Service (FCC-P) Car Call Erase If the number of registered car calls does not correspond to the car operation for independent use, such as maintenance or repair, and Signal and Display Features (ITP) Inter Communication System Emergency Operations and Features (ECL) Emergency Car Lighting (HE-B) Reserved Operation for Emergency Block Sign Type A system which allows communication between passengers inside a car and the building personnel. In the state of emergency, the lift can discontinue the service for other 17 18

FEATURES Table of Features (Optional) Feature Description Feature Description Operational and Service Features Signal and Display Features (ABP) Automatic Bypass (AS) Attendant Service (HOS) Out-of-Service by Hall Key Switch A fully-loaded car bypasses hall calls in order to maintain maximum Exclusive operation where an elevator can be operated using the buttons and switches located in the car operating panel, allowing smooth For maintenance or energy-saving measures, a car can be taken out of (AECC/AECH)) Car Arrival Chime Car or Hall (EXCL) Excluding Operation Signal Light (FHL) Flashing Hall Lantern Electronic chimes sound to indicate that a car will soon arrive. (The chimes are mounted either on the top and bottom of the car, or in each hall.) As the Reserved Operation for Emergency (HE-B) function is started, hall indicator instructs the lantern fair to light special-purposely, remind and take advantage of hall passenger's changing to take other lifts indicate that the car will soon arrive. (NS-CB) Floors Car Button Type (NS/NS-T) Floors Switch/Timer Type (SCS-B) Secret Call Service Door Operation features Emergency Operations and Features (EER-S/P) Earthquake Emergency Return (FER) Fire Emergency Return (OEPS) Operation by Emergency Power Source Automatic/Manual Upon activation of secondary wave seismic sensors, all cars stop at evacuation of passengers. the doors open to ensure safe passenger evacuation. Upon power failure, the building's emergency power moves and stops normal operation will be available with only pre-determined car(s). (SR) Safety Ray (WP) Superviosry Panel A panel installed in a building s supervisory room, etc., which monitors and controls each elevator s status and operations by remote, using indicators and switches which are provided on request. (DKO-TB) Extended Door-Open Button (MBS) Multi-beam Door Sensor A button located inside a car which keeps the doors open for a longer than usual period to allow loading and unloading of a stretcher, baggage, Multiple infrared-light beams cover adoor height of approximately (MELD) Mitsubishi Emergency Landing Device (WP-W)MelEye Mitsubishi Elevators & Escalators Monitoring and Control System Upon power failure,a car equipped with this function automatically moves is 10 meters.)(meld is only applied bellow:750~1000 kg ~105 m/min, 1500~2500 kg 45~105 m/min.) Each elevator s status and operation can be monitored and controlled using an advanced Web-based technology which provides an interface through personal computers. Special optional features such as 19 20

NOTES ON INSTALLANTION PLANNING Elevator Site Requirements MEMO Work Not Included in Elevator Contract Ordering Information 21 22

11-GFCL3-3000A Printed in Taiwan Revised publication effective Jan. 2016. Superseding publication of 1412-GFCL3-3000. Specifications are subject to change without notice. 2016 Mitsubishi Electric Corporation