Masterseal Plus TM technical hotline +44 (0) 268 63720 Improved catch Rear drill holes Available in grey, white and black Fixed gasket speds installation gasket Now has all the features and logic plus range Manufactured from recycled polycarbonate Sealed in use with virtualy any standard 3 amp plug, Patented gel seal
6 Masterseal Plus TM wiring devices ingress protected Switch Socket Outlets, Timer Socket Outlets, And Key Operated Socket Outlets 3 AMP RCD PROTECTED 3 AMP Socket Outlets 3 AMP 6 AMP K6486GRY K6486WHI K6486BLK 3 AMP DP GANG SWITCHED K6482GRY K6482WHI K6482BLK 3 AMP DP SWITCHED K6488GRY K6488WHI K6488BLK 3 AMP DP SWITCHED NEON CLEAR COVER K648GRY K648WHI K648BLK 3 AMP SP GANG WITH ELECTRONIC TIMER- MODULE K6487GRY K6487WHI K6487BLK 3 AMP DP GANG DP KEY OPERATED SOCKET K630GRY K630WHI K630BLK GANG DP ACTIVE CONTROL CIRCUIT K623GRY K623WHI K623BLK SP ACTIVE CONTROL CIRCUIT K6233GRY K6233WHI K6233BLK SP PASSIVE CONTROL CIRCUIT K6480GRY K6480WHI K6480BLK 3 AMP GANG UNSWITCHED K648GRY K648WHI K648BLK 3 AMP UNSWITCHED K6483GRY K6483WHI K6483BLK 6 AMP GANG 2P+E UNSWITCHED (NON UK) woodscrews K6483 is for use with plugs having right angled cable exit. 7 x 0 x 89mm IEC60884-: 2006 BS EN 6029: 992 Fixing Holes Are For No.8 Woodscrews (Not Supplied). K6486 Has 4 X 20mm Entries, On Top, Bottom And Each Side And Is Supplied With An Earth Terminal In The Back Box. 2 Gang Backbox Has Cable Entries, 2 On Top And Centrally On Other 3 Sides. Supplied With Earth Terminals In Backbox. Gang: 7 X 0 X 89mm 2 Gang: 7 X 7 X 89mm Bs 363 Pt. 2: 99 Bs En 6029: 992 Timer Module Meets The Requirements Of IEC 60730- And IEC 60730-2-7 RCD protected sockets are pulsating d.c. and a.c. fault current sensitive. woodscrews Supplied with an earth terminal in the back box. The Sentrysocket has entries. Suitable for supply voltage of 240V a.c. 0Hz Standard Shutters. : 7 x 7 x 89mm BS 7288: 990 BS EN 6029: 992 woodscrews K6480 has 4 x 20mm entries, on top, bottom and each side and is supplied with an earth terminal in the back box. BS 363: Pt2: 99 BS EN 6029: 992 K648 Backbox has cable entries, 2 on top and centrally on other 3 sides. Supplied with earth terminals in backbox. gang: 7 x 0 x 89mm 2 gang: 7 x 7 x 89mm BS 363 Pt.2: 99 BS EN 6029: 992
Masterseal Plus TM 7 technical hotline +44 (0) 268 63720 Key Operated Switches Connection Units Switches Grid Plus 3 AMP 0 AMP 0 AMP IP6 K642GRY K642WHI K642BLK GANG DP KEY OPERATED SWITCH Fitted with a 3A fuse link to BS 362. woodscrews (not supplied) K642 Backbox has 4 x 20mm entries, on top, bottom and each side and is supplied with an earth terminal in the back box. gang: 7 x 0 x 89mm BS EN 60669-: 999 BS EN 6029: 992 K640GRY K640WHI K640BLK 3 AMP DP GANG SWITCHED, FUSED Fitted with a 3A fuse link to BS 362. woodscrews (not supplied) on each edge, and is supplied with an earth terminal in the backbox. 7 x 0 x 89mm BS 363 Pt.4: 99 BS EN 6029: 992 K6400GRY K6400WHI K6400BLK 0 AMP GANG SP ONE-WAY K640GRY K640WHI K640BLK 0 AMP GANG K6402GRY K6402WHI K6402BLK 0 AMP SP ONE-WAY Each switch is fitted with a neon which can be wired as a locator. entries, on top, bottom and terminal in the back box K6406GRY K6406WHI K6406BLK 0 AMP GANG DP ONE-WAY K6407GRY K6407WHI K6407BLK 0 AMP GANG PUSH TO MAKE OR PUSH TO BREAK BELL K6408GRY K6408WHI K6408BLK 0 AMP GANG PUSH TO MAKE OR PUSH TO BREAK PRESS These switches (except push switches) do NOT have to be derated when used with 9 x 9 x 7mm BS EN 60669-: 999 to BS EN 6029: 992 K6409GRY K6409WHI K6409BLK GANG DP ONE-WAY PRESS Each switch is fitted with a neon which can be wired as a locator. entries, on top, bottom and terminal in the back box. These switches (except push switches) do NOT have to be derated when used with 9 x 9 x 7mm BS EN 60669-: 999 to BS EN 6029: 992 K644GRY K644WHI K644BLK Modular Grid Plus Enclosure Supplied with &2 G Inserts on top, bottom and each side. Supplied with an earth terminal and a loop terminal in the backbox. 9 x 9 x 80mm BS EN 60669-: 999 IP6 to BS EN 6029: 992
8 Masterseal Plus TM wiring devices ingress protected Switch Switch Neon Data/Telecom Euro Format Euro Data 0 AMP TELECOM K6420GRY K6420WHI K6420BLK GANG FOR USE WITH ANY ONE SWITCH MODULE K642GRY K642WHI K642BLK GANG WITH NEON FOR USE WITH ANY SWITCH AND ANY NEON MODULE K6422GRY K6422WHI K6422BLK FOR USE WITH ANY TWO SWITCH MODULE 688 BLK 6882 BLK 6883 BLK 0 689 BLK 0 SP ONE-WAY 6892 BLK SP TWO-WAY 0 0 0 6893 BLK 0 INTERMEDIATE 6889 RED 200-20V NEON RED 0 K6423GRY K6423WHI K6423BLK GANG DATA ENCLOSURE FOR 2 MODULE EURO OUTLET HALF MODULE BLANKS SOLD SEPARATELY K820 WHI K820 BLK BT MASTER K82 WHI K82 BLK BT SECONDARY 6896 BLK DP ONE-WAY 0 Each enclosure is fitted with a neon which should be wired as a locator. entries, on top, bottom and terminal in the back box. NOTE: These enclosures are for use with the Masterseal Plus switch and neon modules. 9 x 9 x 7mm to BS EN 6029: 992 For use only with Masterseal Plus switch enclosures. These switches do NOT have to be derated when used with BS EN 60669-: 999 2 data modules can be accommodated providing care is used to ensure that the cables are correctly routed through the outlet. on each edge. Supplied with terminal in the backbox. 7 x 0 x 89mm to BS EN 6029: 992
Masterseal Plus TM 9 technical hotline +44 (0) 268 63720 Euro Data Junction Boxes Flush Mounting Frames Flush Mounting Bezels Conduit Entries Accessories DATA 30 AMP K844WHI RJ4 CAT E ANGLED UNSCREENED K887WHI K887BLK RJ/2 K606GRY K606WHI K606BLK JUNCTION BOX WITH FOUR 4-WAY TERMINALS K600GRY K600WHI 600 GRY 600 WHI K60GRY K60WHI K602GRY K602WHI GANG FLUSH MOUNTING BEZEL FOR USE WITH 7 X 0MM PRODUCTS 602 GRY 602 WHI GANG FLUSH MOUNTING BEZEL FOR USE WITH 9 X 9MM PRODUCTS K603GRY K603WHI FLUSH MOUNTING BEZE 6460 GRY 6460 WHI ENTRY BLANK 646 BLK 646 WHI PVC CABLE ENTRY TO PROVIDE DIRECT ENTRY OF POWER CABLE TO THE UNIT VIA THE BOTTOM BOX ENTRY 6462 BLK 6462 WHI 20MM PLAIN CONDUIT ENTRY PUSH FIT ADAPTOR BETWEEN BACK BOX AND 20MM PLAIN CONDUIT 6837 BLK REPLACEMENT GEL SEAL FOR SOCKETS 9933 M20 EARTH LEAD ADAPTOR FOR EARTHING METAL CONDUIT 6890 GRN REPLACEMENT NEON LOCATOR K844 K887 Fixing holes are for No. 8 The enclosure has 4 entries, on top, bottom and both sides. terminal capacity: Each terminal block accepts four 2.mm2 cables. 9 x 9 x 6mm BS 6220: 983 to BS EN 6029 6463 BLK 6463 WHI 20MM THREADED CONDUIT ENTRY PUSH FIT ADAPTOR BETWEEN BACK BOX AND 20MM THREADED CONDUIT 6464 GRY 6464 WHI BOX COUPLER FOR GANGING ONE MASTERSEAL OR MASTERSEAL PLUS BOX NEXT TO ANOTHER K9944 FLANGE FOR PANEL MOUNTING GANG 9 X 9MM MODULES