F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

Similar documents
AC-115 Compact Networked Single Door Controller. Installation and User Manual

K300/S300 User Manual. K300/S300 ID User Guide

A10/X628 Time & Attendance Terminal

Troubleshooting and Diagnostics

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Adaptability to Enhanced Security

Adaptability to Enhanced Security

USING THE MODEL V800 VELOCITY CLOCK

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Manual. Safescan TA-655

EMBEDDED ACCESS CONTROL Hardware Installation Guide

GSM Alarm System User Manual

ALARM SYSTEM INSTALLATION GUIDE

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING

Connecting to the Internet

F11 User Manual. Version:1.0 Date:Jul. 2010

V2.0 Attendance System Hardware Suite Guide Instructions Manual

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

AD-01 Slave Auto Dialer. Owner s Manual

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Digital Keypad Use s Manual

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

GSM Autodialer Professional GJD700 Speech & Text Autodialer

PK5500 v1.1 Installation Instructions

ProVisual AC-8000P. User Manual. For the optimal use and maintenance of the product, Please read the manual carefully before using it.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

EC150 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC150 Setup Guide - Page 1

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

HDCVI Series DVR Quick Start Guide

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

ipdatatel Wi-Fi BAT Installation and Configuration Guide

INSTALLATION & SERVICE MANUAL. Display Panel

Alarm Security Kit - NVR

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Auto Dialer. Manual E-921APQ E-921GPQ

The Challenger Version 8 User Guide

INSTALLATION MANUAL XM3 Reader

Start Here USB. (802.11) (Ethernet)

Fingerprint Time Attendance Terminal. Hardware Manual Rev: 1.01

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

DC-8706K Auto Dial Alarm System

1 Contactless Smartcard Reader Setup

ES&S AutoMARK. Pre-Election Day Checklist

tattletale User Guide Consumer unit version P a g e

User s Manual for Fingerprint Door Control Software

Home Wi-Fi Gateway Instructions

EC500 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC500 Setup Guide - Page 1

Digital Adapter Easy Setup Guide

Frontier DSL SelfConnect Guide

AC1200 WiFi Range Extender

ATS Control Panel. User s Manual

DVQ-2, DMR8RT, DMR16RT QUICK-START GUIDE

EQUIPMENT SPECIFICATIONS

How To Connect A300 To A300 Time Clock On A Pc Or Mac Computer

CONTENTS 4. HOW TO UNSET THE PANEL...7

GE Simon XT Quick User Guide

Security System User Guide

Wireless Home Security System Product Manual (Model #80355)

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Secure Keypads for access control

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

USING THE MODEL IQ 1000 INTELLICLOCK

VIVA 4G LTE Mini Router. Quick Start Guide

Model 2300DR Installation Guide

User s Information Guide R1A

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Setting Up the ZigBee Ethernet Gateway

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

Manual Serial PCI Cards

FrontDesk Installation And Configuration

Wireless Router Setup Manual

Electronic Time Recorder

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

SMART Board Software for Macintosh FAQ

Each ievo reader needs its own network cable, as each reader has its own IP address. Ensure this has been taken into consideration

GSM Door Phone System

2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

How To Program An Autodialer

Generator Transfer Switch Model # HTS15-AUTO

PC Tab Security System INSTRUCTION MANUAL

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Chapter 1 Connecting the Router to the Internet

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

Transcription:

F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration of the F7_F707_F708 Time & Attendance and Access Control Terminal, refer to the user manual. - 1 -

Table of Contents Before Installation... 1 Front and Read Panel views.5 Optional 3 rd Party Equipment..6 1.0 Installation... 7 1.1 Attaching Mounting Plate..7 1.2 Connecting Power Supply. 9 1.3 Selecting Door Lock 10 1.4 Connecting an electric strike or magnetic lock... 11 1.5 Powering Door Lock... 13 1.6 Connecting switches, door sensor, doorbell, etc..14 1.7 Connecting 3 rd party door controller/panel..16 1.8 Connecting network or computer.17 2.0 Testing..20 2.1 Run Auto Test...20 2.2 Test Fingerprint Enrollment.23 3.0 Fastening to mounting plate and wall..30 4.0 Miscellaneous..31 5.0 Trouble-shooting...32-2 -

Before Installation 1. Prior to beginning installation, cut off all power to prevent personal injury and damage to the F7_F707_F708 and peripheral equipment. 2. Connect the ground wire first, in order to prevent electro-static damage to the F7_F707_F708. 3. Connect 12V DC power supply to the F7_F707_F708 last. If the F7_F707_F708 does not operate properly, always cut off power to it before examining/dismantling. Be advised that wiring the F7_F707_F708 while power is on may cause damage to the terminal. Possible resulting damage from not powering off the F7_F707_F708 prior to wiring is not covered by manufacturer s warranty. 4. Mount the F7_F707_F708 at a comfortable height, typically between 4 and 5 feet from the ground. 5. After installation, remove protective film from the F7_F707_F708 display and fingerprint sensor. 6. To prevent being accidentally locked out while testing the exit-door button, keep a person on the inside of the door. 7. Run the auto-test function to confirm that installation is successful. - 3 -

8. In order to maximize the life of the F7_F707_F708, use the auto-sleep and wake up functions. 9. ONLY use a 12V DC 1.5Amp power supply for proper functioning of the F7_F707_F708 terminal. If the incorrect voltage is used, the F7_F707_F708 may keep rebooting or may not operate the electric door lock (if attached). 10. Improper wiring may cause the F7_F707_F708 s main circuit board and fingerprint sensor to burn out. Resulting damage from improper wiring is not covered under manufacturer s warranty. 11. Only use supplied transformer and cord. Do not attempt extending the cord by cutting and splicing. 12. If using RS485 mode of communication, use only a ZK Software-supplied RS485 converters. Using a 3 rd party RS485 converter may or may not work. If the RS485 cable length exceeds 200 feet, we recommend using a 120Ώ terminator. 13. Refer to the user handbook and operating instructions for further information. - 4 -

Front panel view; F7_F707_F708 Installation Instruction V1.0 Rear panel view; - 5 -

Optional 3 rd party equipment The following equipment is not provided by ZK Software, but often compliments a complete Access Control solution; Part Image Part Image PC Door Lock Door sensor Exit Button Alarm RS485/ RS232 converter Door Controller Network Cable - 6 -

1.0 Installation 1.1 Attach Mounting Plate 1. Take out the F7_F707_F708 fingerprint terminal and remove the screw (screwdriver supplied) which secures the F7_F707_F708 to its mounting plate; 2. Remove mounting plate by grasping the bottom edge and lifting it inward and upward. 3. Determine the position of mounting plate on the wall. We recommend about 4-5 feet from the ground so it is comfortably within reach of most of your users. - 7 -

4. After its position is determined, cut-out square-openings in the walls which correspond to the cut-outs in the F7_F707_F708 s mounting plate for wires to pass through; 5. Use 3 mounting screws (supplied) to affix the F7_F707_F708 mounting plate on the wall. 6. Then secure the F7_F707_F708 to the mounting plate. - 8 -

1.2 Connecting Power Supply F7_F707_F708 operates on 12V DC Power supply and connect the positive and as shown below. If you are connecting a magnetic lock or an electric strike to F7_F707_F708 than we recommend it should draw maximum current of 1A. If you need more power than please use an external power supply of higher current capacity. RS232 RXD +12V Power RS232 TXD Lock COM Lock NO RS485 A Lock NC RS485 B Alarm+ DATA0 Alarm DATA1 Button +5V Output Door Sensor Bell+ Bell 12V DC +Power supply adapter - 9 -

1.3 Selecting door lock For glass doors which swing both in and out, we recommend the use of electro-magnetic door strikes (aka mag locks ). For 1-way opening non-glass doors we recommend the use of electric door strikes, instead. While both locks are equally secure, the mag lock is considered safer than the electric strike, especially during power interruptions. During a power failure caused by fire or other safety threats, the mag lock will fail open and allow people to exit a room/building unhampered. Conversely, the electric strike fails closed. With loss of power you can still exit a door secured by an electric door strike. But you ll need a mechanical device (i.e. door handle or exit bar) to free the door during power interruptions. ZK Software is not responsible for any personal injury or damage caused by power failure. - 10 -

1.4 Connecting an electric strike or magnetic lock F7_F707_F708 has NO and NC closed contacts for controlling the locks. Since there are many different type s of locks available we recommend to connect these locks as per the recommendation of the manufacturers. Ensure that proper voltages are applied to the lock terminals and check on the current ratings of the locks. RS232 R D +12V Power RS232 T D Lock COM Lock NO RS485 A Lock NC RS485 B Alarm+ DATA0 Alarm- DATA1 Button +5V Output Door Sensor Bell+ Bell- + Lock + 12V Power supply adapter - 11 -

RS232 R D +12V Power RS232 T D Lock COM Lock NO RS485 A Lock NC RS485 B Alarm+ DATA0 Alarm- DATA1 Button +5V Output Door Sensor Bell+ Bell- + Lock + 12V Power supply adapter + 12V Power supply adapter RS232 R D +12V Power RS232 T D Lock COM Lock NO RS485 A Lock NC RS485 B Alarm+ DATA0 Alarm- DATA1 Button +5V Output Door Sensor Bell+ Bell- Lock control relay + 12V Power supply adapter + Lock + Lock Power - 12 -

1.5 Powering Door Lock The F7_F707_F708 can supply power directly to a door lock. However, in the following three scenarios, it is recommended that the door lock has an independent power source, and is NOT powered by the F7_F707_F708; If the door lock voltage is not 12V DC then provide separate power to the door lock. If the door lock runs on 12V DC, but requires more than 1A (amp), then provide separate power to the door lock. If the distance between the F7_F707_F708 and door lock is greater than 15 feet, then provide separate power to the door - 13 -

1.6 Connecting switches, door sensor, doorbell, etc. You can connect the exit switch as shown below. This is mainly used for receptionists to open the door for the visitors. The door sensor switch is used to trigger the alarm if the door is kept open for more than specified time. Furthermore, F7_F707_F708 will also send an alert signal if the door is not closed within the specified time. You can connect a doorbell to the F7_F707_F708 as shown below. Visitors can hit this button which will trigger the door bell inside the door. RS232 R D RS232 T D +12V Power Lock COM Lock NO + Siren RS485 A Lock NC RS485 B DATA0 Alarm+ Alarm- Siren + Power supply Door Sensor DATA1 Button +5V Output Exit Switch Doorbell Door Sensor Bell+ Bell- - 14 -

1.7 Connecting 3 rd party door controller/panel The F7_F707_F708 provides standard Wiegand 26-bit output, which can be connected to most 3 rd party access control panels. The F7_F707_F708 connects to the panel just like any card-reader or keypad. The distance from the controller to the F7_F707_F708 cannot be more than 16 feet. If the Wiegand signal must be transferred much further, or if electro-magnetic interference exists, utilize a Wiegand signal amplifier. Use the following connections; Access Controller DATA0 DATA1 +12V RS232 R D +12V Power RS232 T D Lock COM Lock NO RS485 A Lock NC RS485 B Alarm+ DATA0 Alarm- DATA1 Button +5V Output Door Sensor Bell+ Bell- - 15 -

1.8 Connecting network or computer F7_F707_F708 offers RS232 and RS485 interface, or Ethernet connectivity to connect with a computer network. Ethernet connection Option 1: Direct connection to PC via cross-over cable; Option 2: Indirect connection to PC via network router; - 16 -

NIC Ethernet P C R S 2 3 2 1 CD 2 RXD 3 TXD 4 DTR 5 6 DSR 7 RTS 8 CTS 9 RI F7ÓëPC ÉÒÔÍ ¹ý RS232»òEthernet ÉÑ Ïà Á ½Ó RS232 RXD +12V Power RS232 TXD Lock COM Lock NO RS485 A Lock NC RS485 B Alarm+ DATA0 Alarm- DATA1 Button +5V Output Door Sensor Bell+ Bell- - 17 -

RS485 connection RS-485 systems using a bus structure configuration connect the driver to the receiver. The transmission line is made by a group of twisted-pair cables. Each cable has a pair of conductors consisting of inverted and non-inverted signal lines. The inverted line is generally designated by the letter "A" or "-", with the non-inverted line designated as "B" or "+". In order to eliminate or reduce noise, traditional RS485 networks require a 12Ω terminal resistor to be installed at the end of the bus cables based on the physical layout of the twisted-pair cables. In the normal condition the resistor is not installed, only if the bus is extended over 125 feet, the termination must be connected with a terminal resistor. - 18 -

2.0 Test and examine after installation With power on, test for the following: The green LED lights up after power up. 2.1 Run Auto-test; Press the M (Menu) key on the F7. - 19 -

Scroll with the / keys and place the cursor ( Options. ) alongside Menu User Manage Options Press the OK key. The Options Menu will appear; Options Log Opt Access Options Auto Test Scroll with the / keys and place the cursor ( - 20 - ) alongside Auto Test.

Press the OK key. The following screen appears; AutoTest Run ALL Test LCD Test Voice Test FR Reader Key test RTC Test Scroll with the / keys and place the cursor ( you d like to test and press the OK key. ) alongside the feature When finished testing, continue pressing the C (Cancel/ESC) key repeatedly until you return to the Start-Up window. Welcome Check-In HH:MM MM/DD/YY DAY Note: The actual current date/time will appear. - 21 -

2.2 Test Fingerprint Enrollment; Press the M (Menu) key on the F7. Scroll with the / keys and place the cursor ( Manage ) alongside User Menu User Manage Options - 22 -

Press the OK key. F7_F707_F708 Installation Instruction V1.0 Scroll with the / keys and place the cursor ( User. ) alongside Enroll User Manage Enroll User Enroll Admin Press the OK key. Scroll with the / keys and place the cursor ( FP. ) alongside Enroll Enroll User Enroll FP Enroll Pwd FP & Pwd - 23 -

Press the OK key. The F7 will prompt you; Enroll FP New Enroll? ESC OK Press OK. Enroll FP New Enroll? ESC OK Since we are enrolling a New User, press OK. The F7 will then prompt you with the next available User ID; New Enroll ESC UserID 00001-0 OK In this example, no user has yet been enrolled on the F7. So the next available User ID# is 00001. - 24 -

Press the OK key to accept 00001, or manually key in a different number if desired. The F7 will then prompt; New Enroll 00001-0 Place Finger... ESC/Exit - 25 -

Remember the rules for proper finger placement; The user s finger should completely cover the sensor. The finger should be placed flat and in the center of the sensor. The finger should cover at least 80% of the sensor as shown below: The finger should NOT be placed in the following positions: - 26 -

Place your finger on the sensor for a full 2 seconds. After the F7 scans your fingerprint successfully, it will beep and then prompt you briefly with; New Enroll 00001-1 Remove Finger ESC/Exit Then you ll be prompted; New Enroll 00001-1 Second Press ESC/Exit - 27 -

Remove your finger, and then place your finger on the sensor a 2 nd time. Again, you ll be prompted briefly; New Enroll 00001-1 Remove Finger ESC/Exit Remove your finger, and then place your finger on the sensor a 3 rd and final time. You ll then be prompted; New Enroll 00001-0 ESC OK (Save) Press the OK key to accept the newly enrolled finger. The F7 will then prompt you with; New Enroll Continue? ESC OK - 28 -

UserID 0001 has now been successfully enrolled with one fingerprint. If you wish to continue enrolling additional users, press the OK key and follow the same procedures. If you re finished enrolling additional users, press the C (ESC/cancel) key repeatedly, until you return the Start-Up window; Welcome Check-In HH:MM MM/DD/YY DAY Note: The actual current date/time will appear. Test the newly enrolled fingerprint by having UserID 00001 place his/her finger on the sensor. If successful, the F7 will respond with an audible Thank you, and the screen will display; Verify Pin: 00001 Verified. - 29 -

3.0 Fasten F7_F707_F708 to mounting plate/wall Confirm all connecting wires are correct and securely fastened. Properly align the rear metal-plate of the F7_F707_F708 to the mounting plate and then push up on it. Then push the F7_F707_F708 backwards. The F7_F707_F708 is now securely affixed to the mounting plate and wall. Tighten screw on underside of F7_F707_F708. - 30 -

4.0 Miscellaneous 4.1 Reset IMPORTANT NOTE Resetting the F7_F707_F708 does NOT erase any stored data (i.e. templates, transactions, settings). This information will be available as soon as power is restored. To reset the F7_F707_F708 use a small tool (e.g., pin or paperclip) to push in the reset button (labelled reset ) located on the underside of the F7_F707_F708 (see figure below). 4.2 Tamper-proof button When the F7_F707_F708 detects it is being tampered with, it will send an alarm signal. - 31 -

Appendix 5.0 Trouble shooting Trouble Power LED is off F7_F707_F708 is unable to connect with PC LCD displays Please try again. F7_F707_F708 starts up, but cannot enter menu system Cause & Fix Cause : No power or lack of voltage Fix: Check and examine power and ground connections. Also ensure 12V DC power. Cause: Connection may be loose. Fix: Check that the RS232/RS485 or Ethernet connections are secure. Also make sure network/firewall settings are not blocking communication to the F7_F707_F708 Cause: The F7_F707_F708 s fingerprint sensor may have accumulated excess dirt or scratches over a period of time. This message indicates the sensor is unable to obtain a clear image of the fingerprint. Other possible cause may be fingerprint sensor cable has loosened from circuit board. Fix: Try using cellophane tape to remove dirt. Sensor may also need to be repaired/replaced. Cause: Fingerprint sensor cable is loose. Fingerprint sensor is broken. Circuit board is broken. Fix: Remove and plug back in Fingerprint sensor cable. - 32 -

Time continually displays 00:00 after restarting The fingerprint sensor light is off Pressing buttons no longer makes sound. Some users fingerprints sometimes can t be verified. Cause: The clock battery is drained. Fix: Replace battery. Cause: Fingerprint sensor or flat connection cable is loose or broken. Fix: Unplug the cable from the fingerprint sensor and plug it back in again. Cause: Trouble in the buzzer, loudspeaker or circuit. Fix: Need to replace the buzzer and loudspeaker. Cause: The fingerprint quality is poor. Fix: If repeated attempts with the same finger fail, try using a different finger when enrolling. Also reduce fingerprint threshold setting. If user s fingerprints completely unreadable, assign them a PIN number, instead. - 33 -