Energy Management Power Analyzer Type WM14-96 Basic Version

Similar documents
Energy Management Energy Meter Type EM23 DIN

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Panel Meters and Controllers Modular Panel Meter Type EDM 35

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

A project to optimise quality and energy efficiency must include metering

Applications. diris_826_a_1_gb_cat

SOLAR300N Rel /01/10

Energy Management Energy Analyzer Type EM24 DIN

Power Meter Series 700

Quick Connect. quick - simple - efficient.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Digital Panel Meters Modular Indicator and Controller Type UDM35

Installation manual. Generator Paralleling Controller GPC multi-line C

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Preset Counter signo 721

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Telephone- and leased line modem for industrial applications TD-36

M2M The measure of efficiency

3-phase, bidirectional energy meter

PCS0100en Persy Control Services B.V. Netherlands

Digital Clamp-on DMMs with uncompromising performance

SINEAX U553 Transducer for AC Voltage

Static energy meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

NC-12 Modbus Application

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Voltage Regulator SPAU 341 C. Product Guide

Polyphase kwh Electricity Meter

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DC Electronic Loads 8500 series

Duct Humidity Transmitter

Digital input modules

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Control Devices Catalogue. Control Devices. Preferred and Standard Products

FREJA 300 Relay Testing System

Maximum Demand Control

CARLO GAVAZZI MDM 40 TF

smart-house Controller Central Unit Module Type SH2WEB24

Digital Pressure Measuring Instrument MDR480

Rack mounted telephone- and leased line modem for industrial applications

Short information Parameters are programmed via front-side membrane keypad

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

EM-PQ 1500 Power Quality Monitor. Operating Manual

Multifunction devices

Digital multimeters DMG

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

Variable Preset Counter signo 723.1

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

Speed Control Relays SX2

1. SAFETY INFORMATION

Integrating Sound Level Meter and Datalogger

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Current and voltage measuring relays

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Features, Benefits, and Operation

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Safety technique. Emergency stop module BO 5988 safemaster

One Meter Works for Both Energy Saving and Power Quality Surveillance

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

User s Manual. Multifunction Transducer MT440

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Capacitor Protection Relay SPAJ 160 C. Product Guide

AIS750 Series Alarm Annunciator

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Metering Devices IQ Analyzer 6400/6600 Series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Application/Connection Examples

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Disturbance Recoder SPCR 8C27. Product Guide

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

Temperature & Humidity SMS Alert Controller

CQM1-SF200/CS1W-SF200

Technical note NT588 NT604 NT695 NT782

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Thyristor-controlled power supplies and battery chargers

PowerGem Pro Uninterruptible Power Supply

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Eaton s E-Series protective relay family

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

38 Series - Relay interface modules A

is then retained absolutely without interruption.

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Transcription:

Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer with built-in programming keypad. Particularly recommended for displaying the main electrical variables. Housing for panel mounting, Type Selection Range codes (front) protection degree IP65, and optional RS485 serial port or dual pulse output. Parameters programmable by means of CptBSoft. System Class 1 (active energy) Class 2 (reactive energy) Accuracy ±0.5 F.S. (current/voltage) Power analyzer Display of instantaneous variables: 3x3 digit Display of energies: 8+1 digit System variables and phase measurements: W, W dmd, var, VA, VA dmd, PF, V, A, An, A dmd, Hz A max, A dmd max, W dmd max indication Energy measurements: kwh and kvarh Hour counter (5+2 DGT) TRMS meas. of distorted sine waves (voltages/currents) Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC Protection degree (front): IP65 Front dimensions: 96x96mm Optional RS422/485 serial port How to order Model Range code System Power supply Option How to order Power supply WM-96 AV5 3 D PGX CptBSoft CptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables. Options AV5: AV6: 380/660V -/5(6)AAC V-: 185 V to 460 V V-: 320 V to 800 V 0/208V -/5(6)AAC V-: 45 V to 5 V V-: 78 V to 250 V Phase current: 0.03A to 6A eutral current: 0.09 to 6A Input specifications 3 : 1-2-3-phase, balanced/unbalanced load,with or without neutral Rated inputs Current X-S options 3 (non insulated each other) Current SG-PG options 3 (insulated each other) Voltage 4 Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25 C ±5 C, R.H. 60%) 1150W-VA-var, FS:230V, 400V; AV6: 285W-VA-var, FS:57V, 100V Current 0.25 to 6A: ±(0.5% FS +1DGT) 0.03A to : ±(0.5%FS+7DGT) eutral current 0.25 to 6A: ±(1.5% FS +1DGT) 0.09A to : ±(0.5%FS+7DGT) Phase-phase voltage ±(1.5% FS +1 DGT) Phase-neutral voltage ±(0.5% FS + 1 DGT) Active and Apparent power, 0.25 to 6A: ±(1% FS +1DGT); 0.03A to : ±(1% FS +5DGT) Reactive power 0.25 to 6A: ±(2% FS +1DGT); A: 24VAC B: 48VAC C: 115VAC D: 230VAC 3: 18 to 60VDC (not available in case of SG or PG options) Active energy X-S option Reactive energy X-S option Active energy SG-PG opt. Reactive energy SG-PG opt. Frequency Additional errors Humidity Temperature drift Sampling rate Display refresh time Display Type Read-out for instant. var. Read-out for energies X: one S: RS485 port SG: RS485+galvanic insulated measurig inputs PG: Dual pulse output + galvanically insulated measuring inputs. 0.03A to : ±(2% FS +5DGT) Class 2 (start up I : 30mA) Class 3 (start up I : 30mA) Class 1 (start up I : 30mA) Class 2 (start up I : 30mA) ±0.1Hz (48 to 62Hz) 0.3% FS, 60% to 90% RH 200ppm/ C 00 samples/s @ 50Hz 1700 samples/s @ 60Hz 700ms ED, mm 3x3 DGT 3+3+3 DGT (Max indication: 999 999 99.9) Specifications are subject to change without notice WM 96 DS EG 200508 1

Input specifications (cont.) Display (cont.) Read-out for hour counter Measurements Coupling type Crest factor 1+3+3 DGT (Max. indication: 9 999 9.99) Current, voltage, power, power factor, frequency, energy, TRMS measurement of distorted waves. Direct < 3, max 10A peak Input impedance (X-S options) 380/660V - (AV5) 1 MΩ ±5% 0/208V - (AV6) 453 KΩ ±5% Current 0.02Ω Input impedance (PG-SG options) 380/660V - (AV5) 1 MΩ ±1% 0/208V - (AV6) 1 MΩ ±1% Current 0.02Ω Frequency Overload protection Continuos voltage/current For 500ms: voltge/current 48 to 62 Hz 1.2 F.S. 2 Un/36A RS485 Serial Port Specifications RS422/RS485 (on request) Type Connections Addresses Protocol Multidrop bidirectional (static and dynamic variables) 2 or 4 wires, max. distance 00m, termination directly on the instrument 1 to 255, key-pad selectable MODBUS/JBUS Data (bidirectional) Dynamic (reading only) Static (writing only) Data format Baud-rate System, phase variables and energies All configuration parameters 1 bit di start, 8 data bit, no parity, 1 stop bit 9600 bit/s CptBSoft software: parameter programming and reading data CptBSoft Multi language software to program the working parameters of the power analyzer and to read the energies and the instantaneous variables. The program runs under Windows 95/98/98SE/2000/ Working mode Data access T/XP. Two different working modes can be selected: - management of a local RS485 network; - management of communication from a single instrument to PC (RS232); By means of RS485 serial port. Dual pulse output Digital outputs (on request) Pulse outputs umber of outputs umber of pulses Output type 2 (one for kwh one for kvarh) From 0.01 to 999 in compliance with the following formula: [Psys max (kw or kvar)*pulses (pulses/kwh or kvarh)] <400 Relay min current: 0.05A@250VAC/30VDC max current: 5A@250VAC/30VDC Pulse duration Insulation Electrical life: min 2*10 5 cycles Mechanial life: 5*10 6 cycles 100ms <0ms (O) 100ms (OFF) According to E622053-31 By means of relays, 4000 V RMS outputs to measuring inputs, 4000 V RMS output to supply input. Insulation between the two outputs: 1000V RMS 2 Specifications are subject to change without notice WM 96 DS EG 200508

Software functions Password umeric code of max. 3 digits; 2 protection levels of the programming data 1st level Password 0, no protection 2nd level Password from 1 to 999, all data are protected System selection 3-phase with/without n, unbal. 3-phase balanced 3-phase ARO, unbalanced 2-phase Single phase Transformer ratio CT 1 to 999 VT 1.0 to 99.9 Filter Operating range Filtering coefficient 1 to 16 Filter action Displaying 3-phase system with neutral 0 to 100% of the input display scale Measurements, alarms, serial out. (fundamental var: V, A, W and their derived ones). Up to 3 variables per page Page 1: V 1, V 2, V 3 Page 2: V, V 23, V 31 Page 3: A 1, A 2, A 3 Page 4: A 1 dmd, A 2 dmd, A 3 dmd Alarms Reset Page 5: An, An Alarm Page 6: W 1, W 2, W 3 Page 7: PF 1, PF 2, PF 3 Page 8: var 1, var 2, var 3 Page 9: VA 1, VA 2, VA 3 Page 10: VA, W, var Page 11: VA dmd, W dmd, Hz Page : W dmd max (*) Page : Wh (*) Page : varh (*) Page 15: V-, PF, V Alarm Page 16: A max (*) Page 17: A dmd max (*) Page 18: hour counter (*) (*) = These variables are stored in EEPROM when the instrument is switched off Programmable, for the V and An (neutral current). ote: the alarm is only visual, by means of ED on the front of the instrument. Independent alarm (V, An) max: A dmd, W dmd all energies (Wh, varh) and hour counter Power Supply Specifications Auxiliary power supply 230VAC 115VAC 48VAC Power consumption 24VAC 18 to 60VDC AC: 4.5 VA DC: 4W General Specifications Operating temperature Storage temperature Installation category Insulation (for 1 minute) 0 to +50 C (32 to 2 F) (RH < 90% non condensing) -30 to +60 C (-22 to 0 F) (RH < 90% non condensing) Cat. III (IEC 60664, E60664) 4000VAC, 500VDC between mesuring inputs and power supply. 500VAC/DC between mesuring inputs and RS485. 4000VAC, 500VDC between power supply and RS485 Dielectric strength 4000 VAC (for 1 min) EMC Emissions E50084-1 (class A) residential environment, commerce and light industry Specifications are subject to change without notice WM 96 DS EG 200508 3

General Specifications (cont.) EMC (cont.) Immunity E61000-6-2 (class A) industrial environment. Pulse voltage (1.2/50µs) E61000-4-5 Safety standards IEC60664, E60664 Approvals CE, (curus, CSA only X and S options) Connections 5(6) A Screw-type Max cable cross sect. area 2.5 mm 2 Display pages Housing Dimensions (WxHxD) Material Mounting Protection degree Weight 96 x 96 x 63 mm ABS self-extinguishing: U 94 V-0 Panel Front: IP65 (standard), EMA4x, EMA Connections: IP20 Approx. 400 g (pack. incl.) Display variables in 3-phase systems (in a 3-phase system with neutral) o 1 st variable 2 nd variable 3 rd variable ote 1 V 1 V 2 V 3 2 V V 23 V 31 Decimal point blinking on the right of the display 3 A 1 A 2 A 3 4 A 1 dmd A 2 dmd A 3 dmd dmd = demand (integration time selectable from 1 to 30 minutes) 5 An A.n A.n if neutral current alarm is active 6 W 1 W 2 W 3 Decimal point blinking on the right of the display if generated power 7 PF 1 PF 2 PF 3 8 var 1 var 2 var 3 Decimal point blinking on the right of the display if generated power 9 VA 1 VA 2 VA 3 10 VA system W system var system 11 VA dmd W dmd Hz dmd = demand (integration time (system) (system) (system) selectable from 1 to 30 minutes) W dmd MAX Maximum sys power demand Wh (MSD) Wh Wh (SD) The total indication is given in max 3 groups of 3 digits. varh (MSD) varh varh (SD) The total indication is given in max 3 groups of 3 digits. 15 V system A.U PF system A.U= is activated only if one of V is not within the set limits. 16 A MAX max. current among the three phases 17 A dmd max max. dmd current among the three phases 18 h hour counter MSD: most significant digit SD: least significant digit 1 V A VA k M 1) Example of kwh visualization: This example is showing 15 933 453.7 kwh 1 V A VA k M 2 W 2 W h 3 var Hz al PF dmd 2) Example of kvarh visualization: This example is showing 3 553 944.9 kvarh h 3 var Hz al PF dmd 4 Specifications are subject to change without notice WM 96 DS EG 200508

Waveform of the signals that can be measured Figure A Sine wave, undistorted Fundamental content 100% Harmonic content 0% A rms = 1.1107 A Accuracy Figure B Sine wave, indented Fundamental content 10...100% Harmonic content 0...90% Frequency spectrum: 3rd to 16th harmonic Additional error: <1% FS Figure C Sine wave, distorted Fundamental content 70...90% Harmonic content 10...30% Frequency spectrum: 3rd to 16th harmonic Additional error: <0.5% FS kwh, accuracy (RDG) depending on the current kvarh, accuracy (RDG) depending on the current PF=1 +1.5% +1% 0% +1% +1.5% PF=1 PF=0.5 or C0.8 Error 0.10A (0.02In) 0.5A (0.1In) Class 2 accuracy limits (Active energy) 5(6A) Start-up current: 30mA PF=0.5 or C0.8 +4% Error +3% Class 2 +1.5% + 1% Class 3 Class 1 0% Class 2 Class 2-1% -1.5% +3% +4% sinϕ=1 sinϕ=0.5 0.1A (0.02In) 0.5A (0.1In) Class 3 Class 3 accuracy limits (Reactive energy) 5(6A) Start-up current: 30mA : this graph is only referred to instrument models with the SG or PG option. : this graph is only referred to instrument models with the X or S option. Used calculation formulas Phase variables Instantaneous effective voltage Instantaneous active power Instantaneous power factor Instantaneous effective current Instantaneous apparent power Instantaneous reactive power System variables Equivalent 3-phase voltage 3-phase reactive power 3-phase active power 3-phase apparent power 3-phase power factor eutral current An = A 1 + A 2 + A 3 Specifications are subject to change without notice WM 96 DS EG 200508 5

Used calculation formulas (cont.) Energy metering Where: i = considered phase (1, 2 or 3) P = active power Q = reactive power t 1, t 2 = starting and ending time points of consumption recording n = time unit t = time interval between two successive power consumptions n 1, n 2 = starting and ending discrete time points of consumption recording Wiring diagrams Fig. 1 Fig. 2 Fig. 3 17 19 21 15 24 23 26 25 28 27 17 19 21 15 24 23 26 25 28 27 17 19 21 24 23 26 25 1 2 3 1 2 3 1 2 3 CT connection 3CT and 3VT connection ARO and VT connection Fig. 4 Fig. 5 Fig. 6 17 19 15 24 23 26 25 17 15 24 23 17 15 24 23 1 2 1 2 3 1 2-phase connection 3-phase load balanced connection 1-phase connection = 315mA OTE: Only for PG and SG options: the current measuring inputs are galvanically insulated and therefore they can be connected to ground singly. OTE: For all models except for PG or SG the current inputs can be connected to the lines OY by means of current transformers. The direct connection is not allowed. ATTETIO: only one ammeter input can be connected to earth, as shown in the electrical diagrams. 6 Specifications are subject to change without notice WM 96 DS EG 200508

RS485 port connections Dual pulse output connections [a] [b] [c] GD T 9 GD 9 GD 10 T 10 RS485 RS232 11 11 PC Pulse 1 Pulse 2 Fig. 8 4-wire connection [a] [b] [c] GD T 9 GD 9 GD 10 T 10 RS485 RS232 11 11 PC 1 3 116 7 8 9 3 2-wire connection + - Fig. 7: a-ast instrument; b-1...n Instrument c-rs485/232 serial converter Front Panel Description 2 1 1. Key-pad To program the configuration parameters and the display of the variables. S Key to enter programming and confirm selections; Keys to: - programme values; - select functions; - display measuring pages. 2. Display ED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. Dimensions and Panel Cut-out 96mm 96mm 91mm 96mm 61.4mm 15.4mm Specifications are subject to change without notice WM 96 DS EG 200508 7