Control Devices for Pump & Irrigation



Similar documents
SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

HERZ-Thermal Actuators

OPL BASIC. Dosing System for Professional Laundry machines. Contents

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Single sub-base valve

Centro-Matic Automatic Lubrication Systems System Controls

40.3. Control Relays and Timers

SELF-POWERED VOLTAGE DETECTING & PROTECTING RELAY

Liquid Level Limit Switch liquiphant T FTL 20

LC/LCD ranges level controllers

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS)

Safety at a high level!

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

Conlift1, Conlift2, Conlift2 ph+

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

PS1800 Centrifugal Pumping Systems

Turbine Flow Sensor Series VTR

API Marine. BMS Presentation. Ballast Measurement Systems

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

Combi switchbox with integrated 3/2 way pilot valve

General Purpose Relays Types K, R, N, and C

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

MEASURE AND CONTROL INVENTORY MANAGEMENT CONSOLE (IMC) Console for stand alone use Console with PC interface, software & USB cable

Vacuum drying oven for non-flammable solvents

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

No Power Interval Reset Timer Anti Re-Cycle Timer Over Watering Timer Percentage Timer

RY2 miniature industrial relays

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

SWIMMING POOL HEAT PUMP Owners Manual

Thermometer in stainless steel with capillary and switch contacts

Series 8146/5-V37 and Series 8150/5-V37

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Control Panels. Single-phase electric panels for submersible pumps QSM - QPC - QPCS - QSC - QSCS

UNITOR ULTRASONIC cleaning

GROENEVELD AUTOMATIC GREASING SYSTEMS

Operating Instructions for Plastic Flow Meter. Model: KSK

38 Series - Relay interface modules A

WHOLESALE DIRECT INC WEST 65TH STREET

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Solid-State Timer H3G

Magnum Mobile Generator MMG55 Specifications

MANTA Piston Distributor for Oil and Fluid Grease

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

VOYAGER 570G. 744A Sprayer Control

Assisted lift operated 2/2-way solenoid valves Type EV250B

ISO/VDMA Actuators. Engineering GREAT Solutions

swimming pool accessories

Hydraulic Control Solutions

MS41-22Ex0-R/24VDC MS41-22Ex0-R/115VAC MS41-22Ex0-R/230VAC

E2 Series Electric Furnaces

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

CHEMICAL CLEANING UNIT Product number:

HL Series - Commercial Heaters Tankless Water Heating Solutions

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

DCS Input/Output Relay Card Series

WD-AMX Water Detection Controllers

2.24. Pump Controller 704. Data Sheet

38 Series - Relay interface modules A

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

OPERATING AND MAINTENANCE MANUAL

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Control- and feedback head for integrated mounting on Robolux valves Type 2036

PSR The compact range Description

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

Relay mounting systems

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

IEC Connectors. Introduction

SMS 4 / SMS 5 safety mat Product information

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Technical Information

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

SECTION LOW VOLTAGE LIGHTING CONTROLS

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

48 SERIES Relay interface modules 10 A

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

TIG INVERTER INSTRUCTION MANUAL

UNITOR VACUUM cleaners

Self Monitoring Power Supply (BPSM)

Colima Visco and Colima Viscorol Magnetic Level Indicators

Cable Plug acc. to DIN EN , Form A

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Transcription:

Control Devices for Pump & Irrigation Flow Switches Page 5.2 Pressure Switches Page 5.2 Float Switches Page 5.3 Aquaman Filter Flushing Timer Pivot Chemical Controller Blac Bocs Motorscope Surge Arrestors Avanti Pump Protection Relay Avanti Distance Control Unit Avanti Liquid Level Relay Electrode Mechanical Time Clock 5. January 26

FLOW SWITCHES PARTNO HFS-25 DESCRIPTION Flow Switch with change over contacts. bar maximum pressure. " BSP connection 6 paddle Price 7.6 KIT2A62 6 paddle kit for HFS-25 flow switch 5. HFS-25 BRIO2-M BRIO2-M Flow control switch - Performs the operations normally carried out by pressure tank, pressure switch & non-return valve - bar pressure " BSP male connection IP 65 protection / Max. Current: 2 amp Max. temp: 55 C Max. flow: 8 l/min 264. 4 PRESSURE SWITCHES P77AAA-93.5-7 bar pressure. Differential.5-3 bar Max bellow pressure 22 bar 43. P77AAA-93 - bar pressure. Differential - 3 bar Max bellow pressure 5 bar 43. PENN - P77AAA-93 P77AAA-935 3-3 bar pressure. Differential 3-2 bar Max bellow pressure 33 bar 43. ADP Spare for PENN Pressure Switches 57.2 5.2 27 January 26

FLOAT SWITCHES MERCURY SWITCH For regulation of turbulent or suspended agglomerative residues in service & sewer waters. Colour - Orange 5M-MK2 M-MK2 m cable (5m, 2m & 2 lengths available on request) 553. 599. Rated Voltage Load 22v AC/DC A NB. In accordance with SAFETY REGULATIONS, the float switches MUST be connected to a low-voltage control circuit through an isolating transformer, and used in conjunction with suitably rated relays. MERCURY SWITCH ROLLER BALL SWITCH For use in clean liquids for regulation of high & low levels in tanks and cisterns. (limited differential) Colour - Red Amp Switch MICROSTART/C5- MICROSTART/C- m cable 363. 3 528. 2 2 hp Switch MICROSTART/C5-2 MICROSTART/C-2 m cable 48. 3 595. 8 ROLLER BALL SWITCH (A) (2HP) Rated Voltage 25v AC 25v AC Resistive load A A Inductive load 4A 8A Max working pressure bar bar Differential 3 3 ACCESSORIES MATICCW Spare counter weight for float switch 4.5 COUNTER WEIGHT 5.3 January 26

AQUAMAN FILTER FLUSHING TIMERS Run-time: Flushing Time:.3-6 hours.3-6 minutes AQUAMAN FILTER FLUSHING TIMER PARTNO AQUA2S AQUA3S AQUA4S AQUA5S AQUA6S AQUA7S AQUA8S FTSS24AD DESCRIPTION Larger units available on request Master + 2 step Master + 3 step Master + 4 step Master + 5 step Master + 6 step Master + 7 step Master + 8 step Master + step with plug-in base VOLTAGE Price 83. 23. 2433. 2734. 347. 3749. 45. SPARE MODULES FTM24AD FTS24AD Master Slave PIVOT CHEMICAL CONTROLLER Run-time: Dosing Time:.3-6 seconds.3-6 seconds BLAC BOCS PCC2S PCC3S PCC4S PCC5S PCC6S PCC7S PCC8S Master + 2 step Master + 3 step Master + 4 step Master + 5 step Master + 6 step Master + 7 step Master + 8 step Larger units available on request 83. 23. 2433. 2734. 347. 3749. 45. SPARE MODULES PCC24AD PCC24AD Master Slave BLAC BOCS MOTORSCOPE 382 382 3822 3823 3824.37 to.5 Kw 2.2 to 5.5 Kw 7.5 to 8.5 Kw 22. to 75. Kw 93. to 5. Kw 7.5Kw and above, use C.T. Provided. 252. 252. 2367. 2367. 2367. MOTORSCOPE TRIO SUPRA 3 phase up to 5.6 Kw without C.Tx 3 phase 7.5Kw to 37 Kw with C.Tx 2348. 468. SURGE ARRESTORS SURGE ARRESTOR AVSURGE AVSURGE/DIN AVSURGE/DIN8 AVANTI Surge Arrestor - 8KA 28 VAC AVANTI Surge Arrestor - 4KA DIN mount 28 VAC AVANTI Surge Arrestor - 8KA DIN mount 28 VAC 47. 488. 26. 5.4 27 January 26

AVANTI ELECTRONIC MODULES (Refer Section for more details) PUMP PROTECTION RELAYS (PPR) with Underload Restart Function PPR For new installations, a CT and pin base must be purchased with PPR PPR-T8-23 PPR-3T8-4 Single phase PPR Three phase PPR 78. 78. DISTANCE CONTROL UNIT DCU/23STR DCU/4STR Distance Control Unit - single pump Distance Control Unit - single pump 429. 429. DCU/223STR DCU/24STR Distance Control Unit - double pump Distance Control Unit - double pump 66. 66. DCU LIQUID LEVEL CONTROL Filling & Emptying Selectable LLC23 LLC4 LLC Switch - single pump LLC Switch - single pump 323. 323. LLC323 LLC34 LLC Switch - double pump with duty cycle LLC Switch - double pump with duty cycle 23VAC 4VAC 462. 462. LLC ELECTRODE (for use with LLC) AEL Stainless Steel Electrode 79.65 ACCESSORIES AEL ES FMA pin base - surface / DIN mount Flush Mount Kit for Avanti Modules 64. 99. Refer to page:.2 for Wiring Diagram of PPR. MECHANICAL TIMERS - AUTO STOP Panel mount NO + NC contact C53-2 C53-24 2 hour 24 hour 74. 74. MECHANICAL TIMER 5.5 January 26