1 OPERATING LIMITS Useful volume up to : L 9 L Ambient temperature : to + C Max.fluid temperature : + C* passing blade at : mm Ø Inlet dia. : mm DN Ø Outlet dia. : / Ø Vent dia.: mm Ø Cable passage : mm * (+ C for min) SIR 9- INTERMEDIATE LIFTING STATIONS Communal waste water Hz 9 Hmt ppe L L 9 L 9 L APPLICATIONS Lifting of muddied waste water containing faecal matter, industrial effluent, water containing fibre, tissue, straw, non metallic particles, sludge, rainwater or greasy wastewater from kitchens, wherever the discharge level is situated below the level of the sewer, or for transferring water to a distant or elevated treatment works. industrial sites, farms, slaughter-houses, sports complexes, h o t e l s, restaurant kitchens, camp sites, small rural communities, housing estates. AdVANTAGES 9 with cover Completely sealed below the level of the inlet channel. No holes in the bottom part of the tank. Unbreakable tank, unaffected by acidic mixtures, bases, oil, milk or hydrocarbons. Designed to resist to water pressure in the event of flooding thanks to its stabilising fins. Standard version: or grinding pumps. pump version allowing automatic backup in the event of breakdown of one of the pumps;cascade type operation of pumps in the event of increased flow. Ecological, mercury free floaters, pear shaped to avoid snagging paper, fibre, fabric, etc. ; or air pressure switch Lockable cover (protection of people). Vent opening allowing the fitting of a carbon filter (not supplied). Height of tank can be adjusted by adding an extension piece (plus replacement gasket not supplied) or by cutting back the specially designed upper section. System allowing rapid installation and removal of pump(s)by means of a positioning flange and a stainless steel chain. Extension piece 9 (cut-away section) N.T. No -/ENG. - Ed. /-

2 SIR 9- DESIGN Lifting stations comprising - circular concave-bottomed tank with stabilising fins and lifting rings, - cover with stainless steel safety locks (designed to resist foot traffic loading of dan), - or type SDLi pumps: to, kw V single-phase or V three-phase, Hz (see special SDLI notice), - Stainless steel discharge pipework with /, DIN ISO /-G/ (DIN 999) threads, - ball valve, plug valve and stainless steel lifting chain per pump, - float support and: pump : - NIVOSTABLE floats ; or I.P.A.E. - a Yn or YN E control box - fault management board. STATION IDENTIFICATION SINGLE PUMP VERSION : Intermediate lifting station 9 L tank pump Type of pump 9 / SDLi-.T PRINCIPLE OF INSTALLATION SINGLE OR DOUBLE PUMP VERSION: Intermediate lifting station L tank or pumps Type of pump(s) / SDLi-.T atelier pumps : - NIVOSTABLE floats ; or I.P.A.E. - a Yn or YN E control box, - fault management board. possibilities of connection to inlet pipe for 9 Nom dia.; possibilities for Nom dia.. - Comply with EN ; EN -; EN -. STANDARD CONSTRUCTION Standard material : MDPE mm Medium Density Polyethylene station épuration Relevage - assainissement Modules eaux chargées

3 SIR 9- STATIONS DESCRIPTION double pump version Tank. Central support. Fixed nom. dia. coupling Non-return valve. Isolating valve. Tee adapter plug Tee adapter for attaching rinsing hose. Support bar. 9 Lifting chain. Chain support. Gasket. Stainless steel discharge pipe (). Stainless steel discharge pipe (). SDLI pump(s). Cover Floats. 9

4 SIR 9- INTERMEDIATE LIFTING STATION SELECTION CHART inhabitants Equivalent equivalent habitants 99 Number Nombre of de lodgings logements The following values are generally deemed to apply : l/head/day for lower class rural housing l/head/day for higher class rural housing l/head/day for small middle class communities l/head/day for small towns of more than inhabitants l/head/day for small towns of more than inhabitants l/head/day for small towns of more than inhabitants. A B C,,,,,,,,, Volume use utile in en m m A = starting/h démarrages/h B = starting/h démarrages/h C = démarrages/h starting/h 9 L/Head/day L/équ./j L/Head/day L/équ./j L/Head/day L/équ./j L/Head/day L/équ./j L/Head/day L/équ./j L/Head/day L/équ./j HYDRAULIc PERFORMANCES Hm Imp.gpm SDL i /,T SDL i /,T SDL i /,T SDL i /,T SDL i /,T SDL - i Hz Hft Hydraulic perfomances at 9 rpm for a pump in operation. Take into account the loss of head due to : pipes, bends, valves, f l a p s SDL i /,T P kw Qm /h SDL i /,T SDL i /,T SDL i /,T SDL i /,T SDL i /,T SDL i /,T Ql/min Ql/s Relevage - assainissement Modules eaux chargées

5 SIR 9- DIMENSIONS 9 Yn boxes Yn (single pump version) Yn (double pump version). Supplied with the module. Functions Ensures fully automated operation of the station and thermal protection of the pumps : - direct start-up, - automatic pump switching (Yn ), - Integrated sound alarm and fault relay. Control panel Front panel features - General safety switch. - Indicator lights : power on, pump running, fault (pump), direction of rotation detector. - way switch: temporary manual operation, stop, automatic. - single pump version Dimensions Yn Yn Height mm mm Length mm mm Depth mm mm Mass, kg,9 kg Protection IP IP See special Yn information sheet.

6 SIR 9- ELECTRICAL DATA AND DIMENSIONS - double pump version FEATURES a) Electrical - volt single/ volt -phase Hz, - Motor protection by means of Yn or Yn box. b) Installation - The box must be installed in a room or externally under an accessible, rigid, water-tight vandal-proof enclosure. - The station is designed to be able to be placed in green areas. Provide a safety barrier around the cover. Comply with applicable standards when installing the station within a roadway or pavement,and provide an inspection pit with a high strength manhole cover. Recommendation Provide a sand trap before the station inlet where effluent contains a lot of sand and heavy particles, and a grease trap where the water is greasy. c) Packaging - Station delivered on pallets ready for installation, together with instructions for putting into operation. One pallet with the station, the other with the control box and the pumps(s) and accessories. REFERENCE Tension Supply ORDER REFERENCE COMMANDE aliment. voltage Motor P. Intensité Abs. Effluents Nominal Nominal Ø p. moteur rating current abs. inlet entrée Ø outlet sortieø Masse Vent évent Ø câble cable V kw A DN ND DN ND mm mm kg 9/SDLI-T x, / 9/SDLI-,M x, 9, /, 9/SDLI-,T x,, / 9/SDLI-,T x,, / 9/SDLI-,T x,, / 9/SDLI-,T x,, / 9/SDLI-,T x,, / /SDLI-T x, / /SDLI-,M x, 9, /, /SDLI-,T x,, / /SDLI-,T x,, / /SDLI-,T x,, / /SDLI-,T x,, / /SDLI-,T x,, / /SDLI-T x x, / /SDLI-,M x, x9, /, /SDLI,T x, x, / /SDLI-,T x, x, / 9 /SDLI-,T x, x, / /SDLI-,T x, x, / /SDLI-,T x, x, / d) Maintenance - Replacement of spare pump parts or kits containing a number of spare parts : - Mechanical seal kit, please contact us. additional order reference numbers Yn : Current range in A Control box reference Yn PUMP Yn PUMPS, to (Yn) (Yn), to (Yn) (Yn) - I.P.A.E : (+YN E) - NIVOSTABLE (m) : 9 - Fault management board for connection of sensors per pump : OPTIONS and recommended accessories Flexible connection (not supplied). Carbon filter (not supplied). Replacement gasket (not supplied). Tank extension piece :. Relevage - assainissement Modules eaux chargées

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

EVAC ONLINEVAC TECHNICAL DATA 6547655 EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

EVAC ONLINEVAC TECHNICAL DATA 6547655 EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13 Date: 9 Apr 202 Doc. 002967-6547655 6, 24 V DC Ø3 360 Required maintenance 990±0 960 40 040 20 890 350 (P/N 546664) 95±5 67±5 Vacuum sensor G /4 88±5 INLET DN40 943 Connection Frame: Steel S235 EN 0025

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

lifting stations motralec

lifting stations motralec 3.0 lifting stations motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : [email protected] www.motralec.com

More information

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. SANITARY & WASTE WATER PUMPING SYSTEMS Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere. Wallace Pumps solve all those waste disposal problems, big or small, with

More information

1. Description. 2. List of Accessories included A B C F G H

1. Description. 2. List of Accessories included A B C F G H 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to

More information

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812 TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

ACO Building Drainage

ACO Building Drainage ACO Building Drainage Backflow systems Backflow systems 33 Stop that backflow ACO backflow stops and lifting plant Contents Background What causes backflow?... 3 Liability aspects... 3 The backflow level...

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

Manual piston sampler...m 11

Manual piston sampler...m 11 SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water

More information

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PACKAGE SEWAGE TREATMENT SYSTEM Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

Midland Combustion Electric Line Heaters with Integral Panels

Midland Combustion Electric Line Heaters with Integral Panels Midcom Electric Line Heaters are available to work with even the most difficult oils and process fluids when there is no other heating medium available. High viscosity crude oils as well as coal tar, bitumen,

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Flygt 3068, 50Hz. Technical Specification

Flygt 3068, 50Hz. Technical Specification Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating

More information

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Selecting the correct separator Areas of application Hotels Restaurants

More information

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. 1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

VDL 53 - Vacuum drying oven for flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed

More information

DRAIN CLEANING MACHINES

DRAIN CLEANING MACHINES CLEANER, PIPE CLEANING, For blockages in bathroom, toilet & laundry Drain Cleaner H 75 With Bulb Head:DH75B ø20~75mm Manual Plastic wire drum for easy maintenance after use. High quality wire for smooth

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: [email protected] Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9 CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Shower and Floor Gullies Channel Drain and Tile Drain SECTION Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions

More information

MANTA Piston Distributor for Oil and Fluid Grease

MANTA Piston Distributor for Oil and Fluid Grease MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

swimming pool accessories

swimming pool accessories 76 swimming pool accessories 77 Dolphin pool cleaners Dolphin Plus Battery Cordless pool cleaner with lithium ion battery Cleans the pool in 1.5 hours Special programs Clogged filter bag indicator Incl.

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 [email protected] www.viflow.fi

More information

The most advanced Undersink Sullage System with inbuilt controls and alarms.

The most advanced Undersink Sullage System with inbuilt controls and alarms. Optional Interlock Panel The most advanced Undersink Sullage System with inbuilt controls and alarms. The Aquatec Sinktec Sullage System is used to handle sink and basin waste in circumstances where gravity

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual V - JET Counteflow System V-JET Counterflow System Installation and Operation Manual 1. System Installation By purchasing the V - JET counterflow system you have obtained high-quality product, which will

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Pressure regulating valve with modulating kit, type DRV

Pressure regulating valve with modulating kit, type DRV Operation Installation and Maintenance Instructions Pressure regulating valve with modulating kit, type DRV hp-technik GmbH Industriepumpen-Förderaggregate und Anlagenbau Gablonzer Straße 21 D-76185 Karlsruhe

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

kymanual or Automatic - it s your Choice

kymanual or Automatic - it s your Choice . kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw. Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Jay R. Smith Mfg. Co.

Jay R. Smith Mfg. Co. Jay R. Smith Mfg. Co. Automatic Backwater Valve SMITH CUSTOMER DRIVEN FLOOD-GATE FEATURES Index Page Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Valve

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB Grunfos KP sump pump completely made of stainless steel.. Very effective

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Spare Parts Program. Parts, Consumables & Accessories. 800.837.9711 superproductsllc.com

Spare Parts Program. Parts, Consumables & Accessories. 800.837.9711 superproductsllc.com Spare Parts Program Parts, Consumables & Accessories TABLE OF CONTENTS Program Introduction 3 Body 4 5 Boom 5 6 Hydraulic 6 Lights & Accessories 7 Tubes, Nozzles & Hose Fittings 8 11 Vacuum 11 Water 12

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

14. Tools and Software

14. Tools and Software 14. Tools and Software System overview: Geberit welding machine MEDIA 160 and tools... 364 System overview: Geberit welding machine UNIVERSAL 315 and tools... 365 14.1 Tools for Geberit Silent-db20 / Geberit

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Affordable and Reliable. Wastewater. &Rainwater Solutions for Domestic & Commercial Applications FREE. Delivery. On-site advice.

Affordable and Reliable. Wastewater. &Rainwater Solutions for Domestic & Commercial Applications FREE. Delivery. On-site advice. Affordable and Reliable Wastewater &Rainwater Solutions for Domestic & Commercial Applications On-site advice available FREE Delivery Wastewater &Rainwater When budget matters - Count on Clearwater Solutions

More information

Fabricated Drainage Products

Fabricated Drainage Products Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage

More information

1300 MAXTRAK SPECIFICATION

1300 MAXTRAK SPECIFICATION CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having

More information

No: 898501 En Revision 02 2009.08. Parts List. MINEX 8101.171 100-110 222 200-21 3

No: 898501 En Revision 02 2009.08. Parts List.  MINEX 8101.171 100-110 222 200-21 3 No: 89850 En Revision 02 2009.08 Parts List MINEX 80.7 www.grindex.com 2 3 6 3 5 00-0 7 8 9 5 6 7 20 2 22 6 8 9 0 2 3 5 20 2 22 23 23 2 25 26 27 7 8 9 50 5 52 53 5 220 22 222 200-2 3 55 56 57 28 58 59

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

Section 8 Storage Tanks & Equipment

Section 8 Storage Tanks & Equipment Section Storage Tanks & Equipment Table of Contents Section Storage Tanks & Equipment Above Ground Horizontal Tanks... -1-4 Containment Sumps...-5 Fillrite AC & Transfer Pumps... -9-10 Fillrite Diesel

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Product catalogue, pipe and sewer cleaning systems

Product catalogue, pipe and sewer cleaning systems Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public

More information

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information