A Comparison of Screen/Film and Digital Imaging: Image Processing, Image Quality, and Dose



Similar documents
Digital Mammography Update: Design and Characteristics of Current Systems

Quality Control of Full Field Digital Mammography Units

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

The Fundamentals of MTF, Wiener Spectra, and DQE. Motivation

Physics testing of image detectors

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Digital radiography conquers the veterinary world

Radiography: 2D and 3D Metrics of Performance Towards Quality Index

INTRODUCTION. A. Purpose

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Quality Control and Maintenance Programs

The Exposure Index and Its Standardization

Digital Radiography Image Quality: Image Acquisition

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

ACR AAPM SIIM PRACTICE PARAMETER FOR DIGITAL RADIOGRAPHY

Overview of Digital Detector Technology

Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

Page: 1 of 6 Page: 1 of 6

Technical Paper DENTAL MONITOR CALIBRATION

Dental Radiography Core Subject. Digital Radiography

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

Assessment of Camera Phone Distortion and Implications for Watermarking

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Understanding Digital Modalities: System Integration and Use

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Analog and Digital Systems of Imaging in Roentgenodiagnostics

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Lecture 14. Point Spread Function (PSF)

Computed Radiography: Acceptance Testing and Quality Control

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

Medical imaging monitors specification guidelines

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

The Array Scanner as Microdensitometer Surrogate: A Deal with the Devil or... a Great Deal?

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations Andrew P. Smith, Ph.D.

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations

A Proposal for OpenEXR Color Management

Fundamentals of Cone-Beam CT Imaging

Easy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology

Investigation of Color Aliasing of High Spatial Frequencies and Edges for Bayer-Pattern Sensors and Foveon X3 Direct Image Sensors

Checklist for the Qualification of Digital Detector Array Systems

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis

1. Introduction to image processing

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Recommendations for a technical quality control program for diagnostic X-ray equipment

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

DATA RATE AND DYNAMIC RANGE COMPRESSION OF MEDICAL IMAGES: WHICH ONE GOES FIRST? Shahrukh Athar, Hojatollah Yeganeh and Zhou Wang

A PACS-Aware DICOM Image Object

Bergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D.

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Using Automatic Exposure Control in Digital Radiography

A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems

Equipment. Lin muyan. Presented by: CocticaUwititonze Cell:+250 (0)

Chapter 15. Creating the Digital Image. Objectives. Key Terms

Consistency of Softcopy and Hardcopy: Preliminary Experiences with the new DICOM Extensions for Image Display

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Video Camera Image Quality in Physical Electronic Security Systems

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

Possibilities and Limits of Digital Industrial Radiology: - The new high contrast sensitivity technique - Examples and system theoretical analysis

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

Best Practices in Digital Radiography

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

K ODAK D IRECTV IEW CR 850 SYSTEM

Performance testing for Precision 500D Classical R/F System

Picture archiving and communication systems (PACS) and guidelines on diagnostic display devices

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

MACHINE VISION FOR SMARTPHONES. Essential machine vision camera requirements to fulfill the needs of our society

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Laser Diode Gas Sensors

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Scanners and How to Use Them

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

Coronis 5MP Mammo. The standard of care for digital mammography

Integrated Management & Educational Consultancy

WHITE PAPER. Are More Pixels Better? Resolution Does it Really Matter?

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Chapter 6 Telescopes: Portals of Discovery. How does your eye form an image? Refraction. Example: Refraction at Sunset.

proper way. Therefore operator training and certification is key in every inspection program to ensure compliance and improve quality and integrity.

Measuring Line Edge Roughness: Fluctuations in Uncertainty

ON-LINE MONITORING OF AN HADRON BEAM FOR RADIOTHERAPEUTIC TREATMENTS

WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception

Routine Ultrasound Equipment Tests for Quality Assurance. Contents


Radiation safety in dental radiography

Transcription:

AAPM 2005-Continuing Education Course in Radiographic and Fluoroscopy Physics and Technology A Comparison of Screen/Film and Digital Imaging: Image Processing, Image Quality, and Dose Ralph Schaetzing, Ph.D. Agfa Corporation Greenville, SC

This presentation does focus on salient characteristics of two projection-radiography acquisition technology classes does not Analog: screen/film (S/F) Digital: generic focus on technology details (see other presentations) Specific technologies used as examples only address alternatives to projection imaging (i.e., x-sectional) cheerlead No technology-class recommendations - too many other issues 1

Direct Digital Image Acquisition Technologies X-ray quanta meas. output signal Indirect X-ray quanta intermediate(s) meas. output signal Screen/Film + point scan Storage Phosphor + point scan Screen/Film + line scan Storage Phosphor + line scan Silicon Strip + line/slot scan Pressurized Gas + line/slot scan Scintillator + line/slot scan Commonly called Computed Radiography (CR) Photoconductor + flat-panel array Scintillator + area sensor(s) Commonly called Digital Radiography (DR) Scintillator + flat-panel array 2

The Medical Imaging Chain (Analog, Digital) Human Acquire ANALOGUE WORLD (visible) Reproduce Preprocess Process Process (Optimize) Process for Output Store Distribute 3 DIGITAL WORLD (hidden)

The Bigger Picture Producers/Competitors Clinical Technical Regulators/Standardizers A q c u S i P t r r o e R D o re c s e s c e e p r o d u Observers Operational Economic Consumers 4 Imaging and Information System Environment

Outline of Presentation Dose and Image Quality in S/F and Digital Systems Dose requirements: the speed limit Image quality as a dose metric Does image quality really matter? Image Processing in S/F and Digital Systems Image processing for display optimization Image processing for decision support Wrap-up and Conclusions 5

Outline of Presentation Dose and Image Quality in S/F and Digital Systems Dose requirements: the speed limit Image quality as a dose metric Does image quality really matter? Image Processing in S/F and Digital Systems Image processing for display optimization Image processing for decision support Wrap-up and Conclusions 6

When x-ray dose wasn t so important All Images Radiology Centennial, Inc. 7

When x-ray dose became important Biological effects became clearer quickly Radiology Centennial, Inc. Dose: a metric by which to compare systems (and facilities e.g., FDA s NEXT Survey) ALARA Principle: As Low As Reasonably Achievable 8

Comparing Dose Requirements: Speed Analog S/F Digital ISO 9236-1 (2004) Photography -- Sensitometry of screen/film systems for medical radiography -- Part 1: Determination of sensitometric curve shape, speed and average gradient 1000 S = K ( Gy) s µ Speed defined by incident air kerma (K s ) giving net density of 1.0 under specific conditions (exposure, processing, etc.) Linear, wide-latitude response, and variable detector kv-dependence makes definition non-trivial, manufacturer-dependent Confusion and frustration Efforts underway to create standardized definition of speed (AAPM, DIN, IEC, manufacturers) 9

Comparing Dose Requirements: Speed 10 Linear, wide-latitude response of digital systems still confused with dose efficiency Latitude Dose Reduction! (Can always find S/F system that operates at same dose level as digital system) Multiple, different S/F systems needed to cover same exposure range as one digital system Question: even if signal levels matched, is S/F image quality (e.g., sharpness, noise) level comparable to that of digital? 4 3 2 1 X-ray Sensitometry - Screen/Film and CR (Density or CR Signal vs. X-ray Exposure) S/F S=1200 1200 S/F S=400 S/F S=300 CR "pick a speed" 300 0 0.1 1.0 10.0 100.0 1000.0 µgy 4 decades of exposure

Comparing Dose Requirements: Detective Quantum Efficiency (DQE) Input Exposure Signal in Noise in Detector Signal out Noise out Recorded Image (Noise out > Noise in ) DQE = (Measured) Noise from ideal detector* Measured Noise from real detector* *Noise values must be expressed in same units = 1.0 for ideal detector DQE (Contrast or Gain) 2 x (Sharpness) 2 Measured Noise 11 spatial-frequency- and exposure-dependent, i.e., a SURFACE!

Comparing Dose Requirements: Reported DQE(0) Values for S/F and Digital 1.0 Ideal Detector Detective Quantum Efficiency (@ f = 0 cy/mm) 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 R&D Needle scint. + TFT Powder scint. + TFT Powder scint. +CCD Indirect Needle IP-CR Powder IP-CR (dual-sided) Powder IP-CR R&D Photoconductor + TFT (gen. rad.) Direct Screen/Film X-ray film 12

Comparing Dose Requirements: DQE: Caveat Emptor Standard exists IEC 62220-1 (2003) Medical electrical equipment - Characteristics of digital X- ray imaging devices - Part 1: Determination of the detective quantum efficiency But Make sure that standard was followed! My DQE is bigger than your DQE! 13

Which image has the highest quality? A C B D 14

Image Quality: What is it? Image quality depends only on intrinsic, objective physical characteristics of an imaging system, and can be measured independently of an observer Image quality is whatever the observer says it is (i.e., it is a subjective perception of the image, "in the eye of the beholder") Image quality is defined by an observer's ability to achieve an acceptable level of performance for a specified task 15

Image Quality: What is it? Perf.? Performance Measures Perf. Subj.? Diagnostic Accuracy Diagnostic Error Rate Patient Management Patient Outcome? Obj. Subjective Measures Subj. Objective Measures Perception Confidence Preference Obj. Physical Characteristics 16

Radiographic Image Quality: Does it matter? Evolution of Projection Radiography and Image Quality 1895 17 S/F (Blue) DIGITAL ANALOG CR (powder IP, point scan) Direct Film Exposure (no screen) Photon Counting DR (needle scint., TFT) DR (photocond., TFT) DR (scint., CCD) CR (needle IP, line scan) DR (II, CCD) 2005 II/TV (Fluoroscopy) S/F (UV) S/F (Green) Significant image quality changes! Significant dose changes: 50-100x Evolution of Radiologist Error Rate (unaided) 1895 2005 Very little change in performance

Radiographic Image Quality: Does it matter? Imaging system manufacturers are wasting their time trying to maintain or improve image quality because end users can't or don't use it clinically Limiting factor: radiologist Radiologists are so skilled that they can locate the relevant clinical information consistently, independent of image quality (at least, to date) Limiting factor: imaging system 1895 Evolution of Radiologist Error Rate (unaided) If the imaging system is the limiting step New acquisition, image processing systems with unprecedented objective image quality? If the radiologist is the limiting step Decision-support systems: Computer-Aided Detection/Diagnosis 2005 18

Outline of Presentation Dose and Image Quality in S/F and Digital Systems Dose requirements: the speed limit Image quality as a dose metric Does image quality really matter? Image Processing in S/F and Digital Systems Image processing for display optimization Image processing for decision support Wrap-up and Conclusions 19

Medical Image Processing Many Goals Optimize for human vision Optimize for storage Signal contrast Memory requirements Latitude Dynamic range (acquired vs. displayed) Sharpness Noise Optimize for machine vision CAD Storage media requirements Cost Optimize for distribution Network efficiency (bandwidth) Transmission/delivery time (e.g., teleradiology) CAD x Access time (read/write) Cost 20

Image Processing for Display: Optimizing for Human Vision Can you find the 20 blob targets in this image? Agfa MUSICA TM 21 MUSICA = MUlti-Scale Image Contrast Amplification

Image Processing for Display: Optimizing for Human Vision in S/F Detector choices Chemical processing choices Screen Film Exposure choices Technique (kv p, ma, s) Hypersensitization Uniform pre-exposure to light nucleates sub-image that becomes developable with further exposure Chemistry type, activity, seasoning, replenishment Time Temperature Adjacency effect Edge enhancement (unsharp masking!) through control of developer dynamics Viewing choices Improves speed, SNR Viewbox luminance, quality, spectrum, masking, magnif. 22

Image Processing for Display: Optimizing for Human Vision in Digital Wide latitude + post-processing flexibility of most digital systems enables HUGE variety of optimization techniques Manual vs. Semi-automatic (examdependent) processing vs. Fully automatic (hands-free) processing Contrast (Gradation/Tone Scale) Look-up Tables (LUTs) Histogram-based Contrast/Latitude dilemma Sharpness (Edge Enhancement) Unsharp masking Multi-scale techniques (custom contrast at each of a set of frequency bands) Noise (Reduction/Smoothing) Used sparingly (?effect on signals?) 23

Image Processing for Decision Support: Optimizing for Machine Vision (CAD) Computers can be trained to do this well and consistently (for well-defined targets) Sources of radiologist error (chest*) Search/Scanning: 15% Recognition: 37% Perceptual Decision: Interpretive Decision: 48% Performance evaluation nontrivial Pathology/target-dependent Operating point? (TP, FP) Best schemes can outperform radiologists (target-dependent) Radiologist alone Missed Detected CAD alone Missed Marked Missed Radiologist with CAD Missed Detected The Theory of CAD Total Number of Cases 24 *Kundel H, Visual search, object recognition and reader error in radiology, Proc. SPIE 5372 (2004), pp1-11 (SPIE Press, Bellingham WA)

Image Processing for Decision Support: CAD Implementation Issues Detection performance sensitive to acquisition system details Contrast resolution Wide/narrow latitude Linear/nonlinear response Spatial resolution (e.g., pixel size) Noise Operational issues S/F: extra digitization step Consistency of results? Proc. protocol (image vs. study) Testing/Scoring/Training ( truth ) Productivity/Workflow/Recalls Case load (screening?, volume?) Satisfaction of Search (faith vs. blind faith) Observer experience/knowledge Clinical Efficacy Radiologist Acceptance Cost/reimbursement 25

Outline of Presentation Dose and Image Quality in S/F and Digital Systems Dose requirements: the speed limit Image quality as a dose metric Does image quality really matter? Image Processing in S/F and Digital Systems Image processing for display optimization Image processing for decision support Wrap-up and Conclusions 26

Dose Analog or Digital Technologies Quo vadis? S/F or Digital ( ) Image Quality Physical Subjective Performance-based Image Processing Display Optimization S/F S/F Digital Digital ( ) ( ) 27 Decision Support (e.g., CAD)

Back to the Bigger Picture: The Path to System Equilibrium Convenience Producers/Competitors Consistency Clinical Technical Flexibility Regulators/Standardizers A q c u S i P t r r o e R D o re c s e s c e e p r o d u Observers Control Operational Economic 28 Interfaces (e.g., EPR) Consumers Technolust

Thank You for Your Attention