EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

Size: px
Start display at page:

Download "EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams"

Transcription

1 EPEX Direct-to-Digital System for General Radiography Featuring... Versatility for a complete range of general radiographic exams The Hologic EPEX General Radiography System is a direct-to-digital, fully integrated imaging system for general-purpose radiology. Using a single digital detector, the EPEX system can perform almost all general radiographic procedures. This detector replaces both the wall and table Bucky in a conventional radiographic room. Designed for through and cross-table, extremity, upright, wheelchair, and stretcher applications, the system provides high throughput, spectacular images and longterm reliability. The EPEX system uses DirectRay technology to directly capture and convert x-ray energy into a digital image. The unique signal profile produced by DirectRay technology results in high quality digital images across the full range of general radiographic exams a necessity for the successful realization of an all-digital department. The EPEX system consists of the following components: DirectRay x-ray image capture system DirectRay Console Ceiling-mounted Omniflex tube crane X-ray generator Table and detector support

2 See the Difference with DirectRay Technology The Hologic EPEX system offers the highest image quality available in digital radiography because it is built to optimize the DirectRay amorphous selenium (a-se) direct-to-digital detector. Most digital radiography systems use indirect-conversion detectors. These detectors first convert x-rays into light and then convert light energy into electrical signals. Because light is used, the signal profile is degraded and resolution is compromised due to image blur. The Evolution of Digital Radiography Detectors Scintillator screen Film Scintillator screen Screen-Film System Storage phosphor imaging plate Computed Radiography Photostimulatable storage phosphor imaging plate Imaging plate moved to reader Indirect imaging CCD Detector with Scintillator Screen Mirror Scintillator screen Focusing Lenses CCD Cameras Scintillator (Phosphor or Cesium Iodide) with Photodiode Array Surface reflector CsI (Tl) Photodiode array with a-silicon Thin-Film Transistor (TFT) and storage capacitor Direct imaging Amorphous Selenium DirectRay Detector Field electrode Dielectric layer Semiconductor (a-selenium) Electrode collection array with a-silicon Thin-Film Transistor (TFT) matrix and storage capacitor Laser Productivity and Cost Savings Hologic s digital radiography systems have been shown to decrease overall exam time by three times compared with computed radiography systems. For a two-view chest exam, the productivity gain was four-fold.* * DeMaster D, Applied Radiology, March Productivity gains translate into cost savings through more efficient use of space and the ability to accommodate growth in patient volume with existing staff. There is also an operating cost advantage, since there are no cassettes to replace or films to process and store. Minutes Time for Two-view Chest Exam Total Exam Time Last Exposure to Review DR CR

3 Applications Through-table and Extremity Exams Upright Exams

4 Cross-table Exams Stretcher and Wheelchair Exams Optimize Patient Care The EPEX system allows hospitals and imaging centers to optimize patient care by streamlining their diagnostic imaging operation with: Reduced exam time no need for casettes, traditional processing, or exposure calculation time. Improved quality of care because the technologist stays with the patient rather than leave to process film or CR casettes. The potential to reduce dose due to the need for less repeat exposures. The opportunity to speed time to diagnosis with high quality, soft copy images. The capability to make departments more cost-efficient by saving time, materials, and facilities.

5 Typical EPEX System Room Layout EPEX shown in 72" stretcher chest position 19'-0" (579 cm) Recommended Ceiling Height: 9'-3" '-0" (518 cm) Equipment Legend Item Description Wt/lbs. Width Depth Height 001 Omniflex tube mount " 118" Var. 002 EPEX table " 38" Var. 003 X-ray generator cabinet " 21" 71" 004 DirectRay Console " 20" 40" 48" Door (122 cm) 005 DirectRay Digital Bucky (dimensions included with table) 36" Door (92 cm) 004 Omniflex Ceiling-mounted Tube Suspension System 10'-3" 5'-0" Take-up Rail 16'-0" Standard Rails 19" 60" Vertical Travel 9'-3" 32" "

6 EPEX Product Specifications DirectRay X-ray image capture system Digital detector with full field, non-tiled 14 x 17 inch /35 x 43 cm nominal active image area Easy detector rotation for portrait and landscape orientation Accurate image information throughout the full diagnostic range of spatial frequencies (0 to 3.6 cycles/mm) Superior imaging of small anatomical structures such as bone trabeculae or pulmonary calcifications Selenium (a-se) semiconductor x-ray absorber coating over amorphous silicon (a-si) Thin-Film Transistor (TFT) 139 µm detector element pitch 3.6 cycles/mm detector Nyquist frequency Detail equivalent to high-resolution screen-film systems Operated at exposures routinely used for screen-film Wide dynamic range 14-bit data captured DirectRay Console The single DirectRay Console lets technologists control the DirectRay detector and x-ray exposure equipment while providing upstream connectivity to the hospital HIS/RIS and downstream connectivity to DICOM workstations, archives, and printers Patient demographics can be entered via HIS/RIS connectivity (DICOM Worklist), manually via keyboard, or a bar code reader Exam Coach software for tracking the progress of complex exams Anatomically Programmed Radiography (APR) is operator programmable Automatic Exposure Control (AEC) is operator adjustable Two stage exposure button Preview images within 12 seconds of exposure Image formatting at 1, 2 or 4 up DICOM 3.0 Print Management and Storage Service Class network output - Multiple destination routing - Storage Service Class utilizes Grayscale Standard Display Function (GSDF) for image formatting Omniflex ceiling mounted tube suspension Fully counterbalanced Ceiling suspended Microprocessor controlled - Digital S.I.D. display Operator handle allows movement in all directions with one hand Multiplanar motions: Vertical travel: nominal 60 inches/152 cm Vertical rotation: +/- 180 Horizontal rotation: +/- 115 Standard ceiling rails: 192 inches/488 cm Standard carriage rails: 123 inches/312 cm The data in this publication are for illustration purposes only and do not necessarily represent standards or specifications which must be met by Hologic, Inc. Characteristics of the products described in this publication may be changed at any time without notice. Suggested ceiling height: 111 inches/282 cm Electromagnetic positioning brakes Automatic collimation X-ray tube 400,000 heat unit x-ray tube 0.6/1.2 mm focal spots 34/100 kw, 12 target angle X-ray generator 80 kw high frequency output kvp kvp kvp kvp ma Generator control integrated into the DirectRay Console Two-point and three-point manual techniques and manual APR/AEC override capabilities Dual speed starter Line voltage range ± 10% kvp typical high voltage ripple 380, 440 and 480 VAC, 3 phase Table and detector support device High-capacity table 450 lb / 205 kg end-load weight capacity Physical dimensions (W x L) of 38 x 84 inches/ 96 x 213 cm Elevation of 25 to 35 inches/64 to 89 cm Table top thickness: 1.75 in/4.5 cm Multiplanar Bucky and table motion Carbon fiber, 4 way float table top Longitudinal table top travel ± 20 inches, 50 cm Transverse table top travel ± 5 inches, 13 cm 10 inches, 26 cm vertical top travel Electromagnetic positioning brakes 34 inches, 86 cm longitudinal Bucky travel 49 inches, cm vertical Bucky travel Vertical detector tower rotation Tower rotation ± 180 Arm rotation ± 120 Bucky rotation ± 180 Reciprocating grid - Removable 10:1, 70 lines per cm - Aluminum interspace material - Frequency matched to detector to ensure optimum image quality HOLOGIC, INC. North and South America, Middle East, Africa 35 Crosby Drive Bedford, MA Phone: Fax: Asia and Pacific Rim 11/F Nanyang Plaza 57 Hung To Road Kwun Tong, Kowloon Hong Kong Phone: Fax: Europe Horizon Park Leuvensesteenweg 510, BUS Zaventem, Belgium Phone: Fax: [email protected] S-DR-100 US/International (2/02) Hologic, Inc. 2001

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X DIGITAL X-RAY SYSTEM with ceiling mounted tube support Universal Digital Radiographic System Conventional system, full DR components Best-in-class image quality Flexible connectivity to PACS systems General

More information

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen

More information

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General

More information

Digital Mammography Update: Design and Characteristics of Current Systems

Digital Mammography Update: Design and Characteristics of Current Systems : Design and Characteristics of Current Systems Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington AAPM Annual Meeting 2009 Anaheim,

More information

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950 HIGH PERFORMANCE MOBILE SURGICAL C-ARM 1K x 1k CCD Digital Camera System H.F. GENERATOR & ROTATING ANODE TUBE WITH DIGITAL WORKSTATION DESCRIPTION: Mobile Surgical C-arm systems are integrated with a triple

More information

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids Principles of Imaging Science II (RAD 120) Radiographic Grids 1 Image-Forming X-Rays Four X-ray paths a. X-rays interact with patient and scatter away from the receptor b. X-rays interact and are absorbed

More information

A Breakthrough in Breast Specimen Imaging

A Breakthrough in Breast Specimen Imaging BreAST HEALTH SOLUTIONS A Breakthrough in Breast Specimen Imaging Trident Specimen Radiography System Superb Image Quality for Streamlined Workflow The Trident system s sharp, high quality images allow

More information

Page: 1 of 6 Page: 1 of 6

Page: 1 of 6 Page: 1 of 6 Page: 1 of 6 Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique

More information

MEDICAL IMAGING. 90/30 Remote Controlled RF System

MEDICAL IMAGING. 90/30 Remote Controlled RF System MEDICAL IMAGING 90/30 Remote Controlled RF System The Easy solution for your Remote Controlled room Apollo EZ represents the Easy approach for the radiographic/fluoroscopic room and it comes from the experience

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

K ODAK D IRECTV IEW CR 850 SYSTEM

K ODAK D IRECTV IEW CR 850 SYSTEM CR 850 SYSTEM A fast, premium single-cassette CR system HEALTH IMAGING A BETTER V IEW OF L IFE. CR 850 SYSTEM A FAST, PREMIUM SINGLE-CASSETTE CR SYSTEM FOR PRODUCTIVE X-RAY IMAGING Boost productivity with

More information

Overview of Digital Detector Technology

Overview of Digital Detector Technology Overview of Digital Detector Technology J. Anthony Seibert, Ph.D. Department of Radiology University of California, Davis Disclosure Member (uncompensated) Barco-Voxar Medical Advisory Board ALARA (CR

More information

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,

More information

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis David Bernard & Steve Ainsworth Dage Precision Industries Abstract Non-destructive testing during the manufacture of

More information

Digital radiography conquers the veterinary world

Digital radiography conquers the veterinary world Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing

More information

AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM

AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM SAMSUNG SMART DIGITAL RADIOGRAPHY 2012 Samsung Electronics All rights reserved. Samsung Electronics reserves the right to modify the design, packaging, specifications and features shown herein, without

More information

Quality Control of Full Field Digital Mammography Units

Quality Control of Full Field Digital Mammography Units Quality Control of Full Field Digital Mammography Units Melissa C. Martin, M.S., FACMP, FACR, FAAPM [email protected] 310-612-8127 ACMP Annual Meeting Virginia Beach, VA May 2, 2009 History of

More information

Go filmless the easy way Philips Essenta DR Digital radiography system

Go filmless the easy way Philips Essenta DR Digital radiography system Go filmless the easy way Philips Essenta DR Digital radiography system Small effort, Are you still harboring doubts about going digital? Here s the good news. All it takes to work with Essenta DR is one

More information

KS-70. Catheterization Table GENERAL

KS-70. Catheterization Table GENERAL PD505-009A Catheterization Table KS-70 GENERAL This Catheterization Table KS-70, which is combined with X-ray high voltage generator, X-ray tube assembly, X-ray image system (Image Intensifier, Flat Panel

More information

Cardius. XPO Series. Cardius 3 XPO

Cardius. XPO Series. Cardius 3 XPO Cardius XPO Series Cardius 3 XPO Three imaging systems, all of which provide outstanding image quality, superior efficiency, and increased patient comfort. Cardius 2 XPO Includes the standard features

More information

Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations Andrew P. Smith, Ph.D.

Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations Andrew P. Smith, Ph.D. Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations Andrew P. Smith, Ph.D. Introduction Screen-film image receptors have been the standard detector used in conventional

More information

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation LORAD Stereotactic Breast Biopsy System AAPM Spring Clinical Meeting Phoenix, AZ March 17, 2013 Melissa C. Martin, M.S., FACR,

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1

Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1 Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1 Comparison of Amorphous Selenium and Amorphous Silicon Flat-Panel Detectors November 20, 2012 COMPARISON OF FLAT-PANEL DETECTORS 2 Abstract

More information

Equipment. Lin muyan. Presented by: CocticaUwititonze Email: [email protected] Cell:+250 (0)7888 44764

Equipment. Lin muyan. Presented by: CocticaUwititonze Email: costicauwitonze@yahoo.com Cell:+250 (0)7888 44764 Digital Medical Radiography Diagnostic (DR) system X-ray Equipment Presented by: CocticaUwititonze Email: [email protected] Cell:+250 (0)7888 44764 Lin muyan 1. Goals 2. Introduction 3. X-ray machine

More information

Digital Dental X-ray. Midmark Animal Health Products

Digital Dental X-ray. Midmark Animal Health Products Digital Dental X-ray Midmark Animal Health Products Disease you can't see... 60% of periodontal disease lies below the gum line, and many issues aren't detectable via probing or visual inspection.* Don't

More information

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC CHAPTER 5 QC Test For Radiographic Equipment Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC Lesson Outcomes Describe the objectives of each QC test done.(importance)

More information

www.siemens.com/agile Luminos Agile A RADical new way in fluoroscopy Answers for Life

www.siemens.com/agile Luminos Agile A RADical new way in fluoroscopy Answers for Life www.siemens.com/agile Luminos Agile A RADical new way in fluoroscopy Answers for Life 2 Easy patient transfer with table height adjustment from 65 cm -112 cm (26 "- 44 ") True dual-use capability for fluoroscopy

More information

REGIUS History. Touch REGIUS110. REGIUS170 ImagePilot REGIUS150 REGIUS330 CS-1

REGIUS History. Touch REGIUS110. REGIUS170 ImagePilot REGIUS150 REGIUS330 CS-1 Konica Minolta has been a CR technology leader since 1996, consistently designing, developing, and delivering innovative solutions. The REGIUS Σ represents the sum of this experience. REGIUS Σ delivers

More information

The professional for your diagnostics.

The professional for your diagnostics. CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS DIGITAL PANORAMIC X-RAY MADE SIMPLE The professional for your diagnostics. System concept ORTHOPHOS XG 5 completes the next

More information

Digital Radiography Image Quality: Image Acquisition

Digital Radiography Image Quality: Image Acquisition Digital Radiography Image Quality: Image Acquisition Mark B. Williams, PhD a, Elizabeth A. Krupinski, PhD b, Keith J. Strauss, MS c, William K. Breeden, III, MS d, Mark S. Rzeszotarski, PhD e, Kimberly

More information

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography Name: Date: Team: Lab Experiment # 3 Focused Grid Positioning Errors Computed Radiography and Direct Digital Radiography Purpose This experiment is designed to demonstrate the effect of off-level error,

More information

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis Application of Digital Radiography for the Detection and Classification of Pneumoconiosis DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention National Institute for Occupational

More information

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter T.M.Taha Radiation Protection Department, Nuclear Research Center, Atomic Energy Authority, Cairo.P.O.13759 Egypt.

More information

INTRODUCTION. A. Purpose

INTRODUCTION. A. Purpose New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programs Computed Radiography INTRODUCTION A. Purpose This guide describes

More information

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors Application Note Case Study Technology Primer White Paper X-RAY IMAGING Emerging Digital Technology - CMOS Detectors Image Sensors X-Ray DETECTORS Scanners Image Processing Custom Solutions In all domains

More information

HP EliteDisplay LED Backlit Monitors. User Guide

HP EliteDisplay LED Backlit Monitors. User Guide HP EliteDisplay LED Backlit Monitors User Guide 2012, Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. The only warranties for HP

More information

DR Retrofit Kit 1417 WL Configuration Integrated PACS

DR Retrofit Kit 1417 WL Configuration Integrated PACS DR Retrofit Kit 1417 WL Configuration Integrated PACS Description: The DR Retrofit Kit 1417WL - Configuration Integrated PACS makes the use of CR Cassettes/Imaging Plates or the use of analogue x-ray films,

More information

ProOne Digital X-ray Imaging Hardware Diagrams and System Requirements

ProOne Digital X-ray Imaging Hardware Diagrams and System Requirements Digital X-ray Imaging Hardware Diagrams and System Requirements Digital X-Ray Note: An Uninterrupted Power Supply (UPS) / Power Conditioner is recommended for the X-Ray. Install a new Planmeca Power Conditioner

More information

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1. R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction

More information

AXIOM Artis U The little big one for universal angiography and cardiology applications

AXIOM Artis U The little big one for universal angiography and cardiology applications AXIOM Artis U The little big one for universal angiography and cardiology applications AXIOM The versatile system for universal angiography and cardiology applications Unchain your workflow! Ease of Use

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOSCOPY)

More information

Product Catalogue EXAMION Systems

Product Catalogue EXAMION Systems EN Product Catalogue EXAMION Systems... A SYSTEM OF CHOICES INTRODUCTION EXAMION - a business division of Arzt & Praxis GmbH is a worldwide supplier of systems in the field of digital and conventional

More information

Create a premium DR room like no other

Create a premium DR room like no other Table of contents DigitalDiagnost overall benefits 2-3 Radiography rooms DR High performance room 4-5 DR Flex room 6-7 DR Value room 8-9 DR Emergency room 10-11 DR Chest room 12-13 DR room to go 14-15

More information

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MAMMOGRAPHY) SECTION

More information

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical

More information

The convenient and compact CR system for veterinary practices

The convenient and compact CR system for veterinary practices Divario CR-Fvet with dicom PACS DX-R Software CR Systems for the Future The convenient and compact CR system for veterinary practices Divario CR-F20/ F40/ F60/ F80 vet Divario CR-F20/ F40/ F60/ F80 vet

More information

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT Although the medical uses of X-rays to examine a patient without surgery became an amazing medical breakthrough,

More information

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ

More information

Data. microcat +SPECT

Data. microcat +SPECT Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for

More information

The Convenient and Compact CR System for Veterinary Practices

The Convenient and Compact CR System for Veterinary Practices The Convenient and Compact CR System for Veterinary Practices Fire CR+ 20 / 40 / 60 / 80 vet with a throughput of 20 to 70 cassettes per hour and the option of a space - saving wall mount The small and

More information

Universal Mount Industrial Monitors

Universal Mount Industrial Monitors Universal Mount Industrial Monitors Tu Sitio de Automatización! VESA Mount Options Yoke Mount Options Pedestal Mount Options VESA Mount Options Radial Arm Wall Mount Bracket Benchtop Stand Radial Arm Mount

More information

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D.

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D. Slide 1 Digital Mammography Detector QC Slide 2 Introduction What is FFDM QC and why is it important? Eric A. Berns, Ph.D. What to know before you start [email protected] Overview and compare QC tests

More information

A PACS-Aware DICOM Image Object

A PACS-Aware DICOM Image Object Designing and Implementing A PACS-Aware DICOM Image Object For Digital X-ray, Mammography and Intraoral Applications David A. Clunie Quintiles Intelligent Imaging Clear Vision for the Healthcare Industry

More information

Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet

Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet Description The AEDB-9140 series are three channel optical incremental encoder modules

More information

Dental Radiography Core Subject. Digital Radiography

Dental Radiography Core Subject. Digital Radiography Dental Radiography Core Subject Digital Radiography Aims: To develop an understanding of the history of digital radiography, the different types of digital x-rays and the advantages and disadvantages of

More information

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13 Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer

More information

Complete coverage extends beyond 360.

Complete coverage extends beyond 360. ERGON 3 BOOMS Complete coverage extends beyond 360. Skytron helps healthcare facilities realize a whole new degree of coverage. Ergon 3 booms are designed to provide 360 equipment coverage but they do

More information

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Radiographic Image Production X-ray photons emitted from the x-ray tube interact with the body, exit the patient (exit beam) and interact

More information

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through

More information

Mammomat Inspiration Mammomat Inspiration Prime

Mammomat Inspiration Mammomat Inspiration Prime s Data Sheet Mammomat Inspiration Mammomat Inspiration Prime Digital Mammography Platform for Screening, Diagnostics, Biopsy and Tomosynthesis www.siemens.com/inspiration Mammomat Inspiration Digital Mammography

More information

Chapter 15. Creating the Digital Image. Objectives. Key Terms

Chapter 15. Creating the Digital Image. Objectives. Key Terms Chapter 15 Creating the Digital Image Objectives Describe how a digital image is created and processed. Sequence the steps of image production and evaluation of the digital image. Identify the components

More information

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 2166-Handout College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 13 September - 1 October, 2010 Digital Radiography Image Parameters SNR,

More information

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School Digital Breast Tomosynthesis

More information

www.icrcompany.com I SEE THE FUTURE

www.icrcompany.com I SEE THE FUTURE www.icrcompany.com I SEE THE FUTURE Stephen Neushul saw the future when he first designed a film scanner back in 1990 called the OmniMedia scanner. He built the scanner with a fixed light source, an innovation

More information

thyroid uptake systems www.capintec.com

thyroid uptake systems www.capintec.com 64 thyroid uptake systems Captus 3000 Thyroid Uptake System Comprehensive Software Quick-start feature for rapid set-up User defined, HIPAA compliant counting protocols Thyroid uptake Wipe test Bioassay

More information

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION Publication Date: November 2010 Implementation Date: March 2011 The purpose of the American Registry of Radiologic Technologists Fluoroscopy Examination

More information

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS Note: This is a courtesy copy and is not the official version of this rule. The official, legally effective version of this rule is available through www.lexisnexic.com/bookstore (Phone: (800) 223-1940).

More information

X-Mind. Instinct for perfection

X-Mind. Instinct for perfection X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOGRAPHY)

More information

HP Compaq LA1905wl, LA1905wg, LA2205wg, LA2205wl, LA22f, LA2405wg, and LA2405x LCD Monitors. User Guide

HP Compaq LA1905wl, LA1905wg, LA2205wg, LA2205wl, LA22f, LA2405wg, and LA2405x LCD Monitors. User Guide HP Compaq LA1905wl, LA1905wg, LA2205wg, LA2205wl, LA22f, LA2405wg, and LA2405x LCD Monitors User Guide 2009 2012 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows Vista are either

More information

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology

More information

Clean, Sustainable Energy from the Sun Now, and for Our Children s Future

Clean, Sustainable Energy from the Sun Now, and for Our Children s Future Clean, Sustainable Energy from the Sun Now, and for Our Children s Future An Industry Leader NovaSolar is an industry leader in manufacturing thin-film silicon based solar panels and constructing large

More information

Modern Fluoroscopy Imaging Systems

Modern Fluoroscopy Imaging Systems Modern Fluoroscopy Imaging Systems Eric Gingold, PhD Thomas Jefferson University, Philadelphia, PA SUMMARY Fluoroscopy, or real-time projection X-ray imaging, has been in clinical use since shortly after

More information

PLANMED SOPHIE MAMMOGRAPHY X-RAY UNIT TECHNICAL MANUAL 788405/11 LAT LAT SIN DEX. kv kv. mas. mas CTL

PLANMED SOPHIE MAMMOGRAPHY X-RAY UNIT TECHNICAL MANUAL 788405/11 LAT LAT SIN DEX. kv kv. mas. mas CTL LAT mas 8 3 2 1 LAT mas PLANMED SOPHIE MAMMOGRAPHY X-RAY UNIT OBL CC OBL SIN DEX kv kv TECHNICAL MANUAL En 788405/11 TABLE OF CONTENTS Chapter A Chapter B Chapter C GENERAL & TECHNICAL DATA 1 WARNINGS...............................................

More information

Digital panoramic X-ray for practical diagnostics

Digital panoramic X-ray for practical diagnostics ORTHOPHOS XG 3 instruments treatment centers Imaging systems cad/cam systems ORTHOPHOS XG 3 Digital panoramic X-ray for practical diagnostics System concept Standard panoramic X-ray with proven technology.

More information

The Exposure Index and Its Standardization

The Exposure Index and Its Standardization The Exposure Index and Its Standardization Ulrich Neitzel Philips Medical Systems Clinical Science Hamburg, Germany [email protected] Content The Exposure Index (EI) What is it? What is it good

More information

DENTAL Cone beam 3D X-RAY SYSTEM with

DENTAL Cone beam 3D X-RAY SYSTEM with VERSATILE INTUITIVE efficient DENTAL Cone beam 3D X-RAY SYSTEM with dedicated panoramic imaging With thirty years of experience in designing and manufacturing state-of-the-art dental panoramic and tomographic

More information

HP Compaq LA1956x, LA2006x, LA2206x, and LA2306x LED Backlit LCD Monitors. User Guide

HP Compaq LA1956x, LA2006x, LA2206x, and LA2306x LED Backlit LCD Monitors. User Guide HP Compaq LA1956x, LA2006x, LA2206x, and LA2306x LED Backlit LCD Monitors User Guide 2010-2012, Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows Vista are either trademarks or

More information

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES (a) Applicability Quality assurance programs as described in paragraph (c) of this section are recommended for all diagnostic radiology facilities.

More information

Systematic X-ray diagnostics as flexible and individual as your dental practice.

Systematic X-ray diagnostics as flexible and individual as your dental practice. CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS XIOS PLUS THE INTRAORAL SENSOR SYSTEM Systematic X-ray diagnostics as flexible and individual as your dental practice. T h

More information

A d v a n c e d 1 2 8

A d v a n c e d 1 2 8 Advanced 128 SCENARIA Advanced 128 Hitachi Innovation at Work for You. Continuing its commitment to the SCENARIA scalable CT platform, Hitachi introduces cutting-edge 128-slice technology with the SCENARIA

More information

Radiation safety in dental radiography

Radiation safety in dental radiography Radiation safety in dental radiography Dental Radiography Series The goal of dental radiography is to obtain diagnostic information while keeping the exposure to the patient and dental staff at minimum

More information

Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound)

Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound) Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound) UNSPSC Code: ECRI Code: 1. Description of Function 1.1 Cardiac Catheterization

More information

Rodenstock Photo Optics

Rodenstock Photo Optics Rogonar Rogonar-S Rodagon Apo-Rodagon N Rodagon-WA Apo-Rodagon-D Accessories: Modular-Focus Lenses for Enlarging, CCD Photos and Video To reproduce analog photographs as pictures on paper requires two

More information

Interfacing Fuji CR in a DICOM Network Environment

Interfacing Fuji CR in a DICOM Network Environment Interfacing Fuji CR in a DICOM Network Environment Wayne T. DeJarnette, Ph.D., Valmore Albrecht, RT, Alan Orth, RT, Jon Sayer, M.S. DeJarnette Research Systems, Inc. 401 Washington Avenue Towson, MD 21204

More information

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life. Veraview IC5 HD High definition, digital imaging excellence Thinking ahead. Focused on life. Thinking ahead. Focused on life. 2 3 IC5 HD Super High-Speed with High Definition Clarity For dental radiology

More information

Update on ACR Digital Mammography QC Manual

Update on ACR Digital Mammography QC Manual Update on ACR Digital Mammography QC Manual Priscilla F. Butler, M.S. Medical Physicist and Senior Director, ACR, Reston, VA (with thanks to Eric Berns, Ph.D.) Overview Phantom Specifications QC Manual

More information

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic) GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES 1. PROTECTIVE SCREENS (a) Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic) Typically, 15 kg m -2 (1.3 mm) sheet lead or its shielding

More information

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the

More information

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered vs. Wall-Mount X-Ray X Systems Edgar Bailey*, MSEHE, CHP Consultant Joel Gray*, PhD, FAAPM DIQUAD, LLC

More information

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels Scanner Parts Start and indicator light Photo Print USB port The has a transparency unit built into the scanner lid and holder for 35 mm film and slides: EPSON Perfection 1650 owners can purchase an optional

More information

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7) Q.A. Collectible Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7) Mammography Phantom Image Quality Evaluation (from the American College of Radiology 1999 Mammography Quality

More information

CR 30-Xm. CR 30-Xm Digitizer

CR 30-Xm. CR 30-Xm Digitizer D I G I T I Z E R CR 30-Xm Complete solution for digital mammography and all general radiography applications The CR 30-Xm is a versatile computed radiography (CR) digitizer that can handle digital mammography,

More information

Physics testing of image detectors

Physics testing of image detectors Physics testing of image detectors Parameters to test Spatial resolution Contrast resolution Uniformity/geometric distortion Features and Weaknesses of Phantoms for CR/DR System Testing Dose response/signal

More information

Datex-Ohmeda Critical Care Monitor

Datex-Ohmeda Critical Care Monitor GE Healthcare Datex-Ohmeda Critical Care Monitor Comprehensive monitoring for the challenging Critical Care environment Critical Care monitor offers a flexible range of module frame options, displays and

More information

301.7D. Mini Hydraulic Excavator

301.7D. Mini Hydraulic Excavator 301.7D Mini Hydraulic Excavator Engine Weights Gross Power (ISO 14396) 17.9 kw 24.3 hp Operating Weight with Canopy 1610 kg 3,550 lb Net Power 13.2 kw 17.7 hp Operating Weight with Cab 1720 kg 3,792 lb

More information

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations Alzen,, G., Beiderwellen,, K., Volz,, M., Berthold,, L.D.,

More information

Innomed Medical. Catalogue

Innomed Medical. Catalogue Innomed Medical Catalogue Innomed Innomed Medical Innomed medical Innomed Inc. was founded in 1989 by young engineers with the goal of developing and manufacturing medical devices that meet the modern

More information