- Sybil Scott
- 10 years ago
- Views:
Transcription
1 Application Note Case Study Technology Primer White Paper X-RAY IMAGING Emerging Digital Technology - CMOS Detectors Image Sensors X-Ray DETECTORS Scanners Image Processing Custom Solutions
2 In all domains of Medical, Dental and Scientific X-Ray imaging, the replacement of film and analog video imaging techniques with a fully digital workflow is underway. Digital X-Ray Technology Workflow Benefits: increased operational efficiency resulting in higher patient comfort; the adoption of digital information workflow and archival infrastructure; opportunity for digital communication and collaboration with peers at remote sites advanced digital image processing capabilities; and lower X-Ray dose with real-time image availability Shad-o-Box 1280 HS There are four primary digital X-Ray technologies in use today, these include: Computed Radiography - uses phosphor imaging plates that are converted to digital format in a separate scanning operation (in a similar manner to traditional film-scanning) and cannot be used for real-time X-Ray imaging such as endovascular procedures. Image Intensified CCD-cameras (II-CCD) - in which the x-ray signal is converted to electrical charges (electrons), which are multiplied and converted to visible light photons inside a high voltage glass vacuum tube. The visible light is imaged onto a CCD-camera to generate real-time images at low x-ray dose levels, e.g. to act as the surgeon s eyes during minimally invasive procedures. Although recognized for their excellent for low-dose image quality and cost-effectiveness, II-CCD cameras offer significant drawbacks in terms of physical size, inability to support challenging projections, vulnerability and shorter intervals between calibrations. Flat Direct Detectors - Direct conversion uses either amorphous selenium (ase), cadmium telluride (CdTe) or mercuric iodine (HgI2) layers to convert X-Ray photons directly to electrons for immediate image capture. An important drawback of selenium is the instability and mechanical vulnerability of the material over time and under normal transport temperature conditions, as well as the environmental impact during production and repair or disposal. Amorphous selenium is also suffering from image lag, a memory effect where information from previous images is retained during next captures, rendering the technology unsuitable for real-time imaging applications. Flat Indirect Detectors - As the most common method, indirect detection uses scintillators (such as Gadolinium Oxides or Cesium- Iodides) to convert X-Rays to visible light. Traditionally, the light generated by the scintillator is imaged onto a CCD sensor using a bulky lens system. In modern flat-panel detectors, the scintillator output is captured by either an amorphous silicon (TFT) panel or CMOS sensor that converts the image to digital format. Teledyne DALSA is a leader in the design and manufacture of CCD (Charge Coupled Device) and CMOS (Complementary Metal-Oxide Semiconductor) for digital medical imaging technology. This technology primer examines the unique engineering features and panel architecture of Teledyne DALSA s advanced CMOS detectors. CMOS Imaging Technology CMOS image detectors offer numerous advantages including the ability to record smaller image details at higher resolutions allowing for the diagnostics of medical anomalies at earlier stages, and significantly increasing the probability of early intervention, patient recovery and reduced treatment costs. Current and planned wafer-scale X-Ray CMOS image sensor designs are using pixel pitches ranging from 20 to 100 microns. Another important benefit of CMOS image sensors is the absence of so-called image lag, or the presence of residual image information in successive images, that is typical of amorphous TFT technologies. Image lag leads to poor quality images because of small image displacement. The image lag in Teledyne DALSA s X-Ray CMOS technology is less than 0.1%. 02 Teledyne DALSA X-Ray Imaging Emerging Digital Technology - CMOS Detectors
3 Low Dose Image Quality Active Pixel Sensor technology and expertise in low noise circuit design are the hallmark s of Teledyne DALSA s CMOS X-Ray image sensors. Our CMOS image sensors exhibit unrivalled low readout noise levels and deliver superior Dynamic Range even at low X-Ray dose, contributing to the high image quality required to support medical diagnostics. Teledyne DALSA s active pixel implementation process significantly reduces the read noise which typically dominates system noise when compared with amorphous silicon (TFT) based detectors. Our CMOS detector deliver low-dose image quality equal to or even surpassing high quality II-CCD systems, combined with the form factor and patient comfort advantages offered by flat detectors. On system level, the low-noise raw images from Teledyne DALSA s CMOS detectors require less pre-processing before the diagnostics image enhancements, preserving image detail, and reducing system processing overhead and complexity. DETECTIVE QUANTUM EFFICIENCY High DQE (the efficient use of incoming x-rays) is vital to minimizing patient dose and obtaining the best quality image to support further medical image processing and diagnostics. Teledyne DALSA s CMOS detectors deliver industry leading DQE performance as a result of our low readout noise and ability to resolve very small image details at high spatial frequencies. High-Speed, High Resolution Readout Taking full advantage of the high-speed capabilities of crystalline silicon material, Teledyne DALSA CMOS X-Ray detectors deliver detailed images at rates exceeding 30fps, at full resolution and each with excellent image quality. OEM system architects have a choice to achieve even higher speeds either through defining a specific region of interest (ROI or windowing ) or by selecting one of the flexible pixel binning modes. Thanks to the advanced processing technology and small feature size, our CMOS detectors offer the capability to create x-ray detectors with very high resolution, without sacrificing the pixel s ability to efficiently detect and convert the incoming x-ray signal. The ability to create CMOS pixels with high optical aperture (or fill factor ) is unmatched by the resolution capabilities of either amorphous or imageintensified detector technologies. Teledyne DALSA X-Ray Imaging Emerging Digital Technology - CMOS Detectors 03
4 Switchable In-Pixel Gain More and more medical modalities offer combined static (still) and dynamic (real-time) imaging capabilities. As the total X-Ray dose to which a patient can be exposed is strictly regulated, the amount of X-Ray dose available per image in dynamic mode is much less when compared to static images. A traditional pixel with a fixed signal gain, optimized to handle the large dose required for still images, will only utilize a fraction of the dynamic range capability when operated in real-time imaging applications. Low dose results in a lower signal level which necessitates the application of higher analog gain to the output signal. In this case both the X-Ray signal and the readout noise are amplified which lowers the signal-to-noise ratio. Readout noise is one of the most important limiting factors of image quality when capturing images under low dose conditions. The advanced Teledyne DALSA CMOS pixel design offers the ability to switch between different pixel charge capacities, each optimized for a specific imaging mode. This eliminates the need for additional gain that amplifies readout noise. Switching is done via software and can be programmed in between consecutive frames. Dynamic images for video analysis are crisp and clear, and do not suffer from low signal-to-noise ratio (SNR) after the required contrast stretching. The switchable pixel full well capacity also has advantages for binned mode operation when higher frame rates and higher sensitivity are desired. Pixel binning can be used to increase the frame rate, but generally the sensitivity is not increased since the saturation charge is increased by the binning factor. An improvement of the SNR in binned operation would be very welcome. The Teledyne DALSA switchable pixel achieves higher frame rates and higher sensitivity when operated in binned mode. A sensitivity increase of up to a factor of 4 is within reach of the technology. IMAGES 30fps 40kV/20uA (46nGy/FRAME) 100 FRAMES AVERAGE 04 Teledyne DALSA X-Ray Imaging Emerging Digital Technology - CMOS Detectors
5 Scalability Teledyne DALSA CMOS X-Ray detectors are created from individual CMOS sensor tiles. These buttable sensors are designed with flexibility in mind for assembly into large two-dimensional arrays with less than one pixel spacing in between individual sensors. This modularity enables multiple detectors with different active areas and resolutions to exist within the same sensor design, leveraging investments in development and production tooling while offering the same high imaging quality performance for multiple detector formats, optimized for a wide range of applications. Real-Time Image Preview (RTIP) To facilitate medical diagnostics, it s important to have access to correctly exposed X-Ray images. However, to minimize patient dose and to maximize equipment utilization, it is neither practical nor acceptable to take multiple X-Ray exposures to determine the optimal X-Ray setting. Ion chambers are most often used to achieve a better X-Ray exposure on the first attempt, but ion chambers can only report the average exposure averaged over a large area through a single analog signal. 23X28CM Teledyne Dalsa FULL FIELD DIGITAL MAMMOGRAPHY CMOS DETECTOR, FEATURING A 2X3 ARRAY OF CMOS IMAGE SENSOR TILES WITH A 33 MICRON PIXEL PITCH. TOTAL RESOLUTION: 60MP Teledyne DALSA CMOS X-Ray detectors offer a unique way to ensure optimal X-Ray exposure for every image. A grid of dose-sensing pixels is embedded in and distributed over the full active image area, which can be read repeatedly at high speed during the actual X-Ray exposure period. Because dose sensing pixels are exactly the same as the pixels in a final image, the low-resolution dose sensing image delivers a qualitative and quantitative thumbnail preview of the final X-Ray image. Read-out of these RTIP pixels is non-destructive and delivers highly valuable image statistics to support intelligent exposure and contrast control algorithms during the actual X-Ray exposure. By using this information to control X-Ray exposure parameters, the highest possible image quality is achieved while the patient is exposed to the lowest possible X-Ray dose in a first-time-right procedure. This is critically important for single-shot applications like mammography screening. PERSPECTIVE ILLUSTRATION OF PIXEL ARRAY SHOWING THE UNIFORMLY DISTRIBUTED RTIP PIXELS AS LIGHTER PIXELS Teledyne DALSA X-Ray Imaging Emerging Digital Technology - CMOS Detectors 05
6 Lifetime Reliability Similar to human bone and tissue, image sensor structures suffer damage from high-energy X-Ray photons, which results in increased noise (or reduced signal-to-noise ratio). This will become increasingly more apparent throughout the lifetime of the detector. Through many years of experience and a thorough understanding of the advanced processes in CMOS manufacturing, Teledyne DALSA has created a proprietary pixel design that is far more resistant to performance degradation from X-Ray radiation. By isolating and protecting critical structures within the basic pixel cell design, the pixel performance remains constant even after high total ionization dose, enabling long operating lifetimes and less frequent calibration routines. INTRA-ORAL DENTAL CMOS-SENSOR WITH INTEGRATED CIRCUIT DRIVERS AND 12-BIT ANALOG-TO-DIGITAL CONVERSION Unlike amorphous technology, the advanced CMOS design and manufacturing process supports the integration of sensor control, readout and signal digitization functionality from the peripheral electronics into the pixel array. This ability reduces component and interconnect count, reducing system cost and assembly complexity while improving product reliability at the same time. The low power consumption of crystalline CMOS detectors also eliminates the need for active cooling, which allows the use of detectors in environments with less stringent temperature conditioning. Cooler-running detectors deliver better image quality over longer lifetimes. Teledyne DALSA CMOS detectors deliver constantly high imaging performance throughout their extended product lifetime. Extended equipment lifetime and reduced maintenance downtime deliver more efficient equipment utilization and increased patient throughput without the need to reschedule appointments. 06 Teledyne DALSA X-Ray Imaging Emerging Digital Technology - CMOS Detectors
7 Teledyne DALSA knows the highly regulatory stringent quality requirements for medical and scientific imaging applications. We offer OEMs more than just a technology advantage; we provide a comprehensive consultation program to meet your business model and a single point of accountability for service, support and manufacturing. Our imaging technology is backed by a field proven track record and an extensive install base; propelled by next generation R&D and delivered by a dedicated and highly trained team of imaging engineers. Teledyne DALSA X-Ray detectors and sensors are designed to deliver the highest imaging quality for improved diagnostics, while optimizing patient comfort and safety including: The ability to offer lower noise and higher image quality which in-turn facilitates improved diagnostics, more accurate procedures and potentially contributes to higher patient survival rates and lower treatment costs Implementation of dose-sensing to optimize image quality in first-time-right exposures, resulting in reduced patient dose, increased patient comfort and workflow efficiency Optimized imaging modes for static and dynamic procedures, best of both worlds, offering true integration of modalities and more effective utilization of capital investments without sacrificing diagnostic quality. Provides radiation hard pixel technology which delivers constant and reliable operation throughout extended periods of daily use, reducing periodic re-calibration and system down-time to a minimum, optimizing patient throughput. Teledyne DALSA X-Ray Imaging Emerging Digital Technology - CMOS Detectors 07
8 Americas Waterloo, ON Tel: europe Eindhoven, The Netherlands Tel: asia pacific Tokyo, Japan Tel: Teledyne DALSA is an international leader in digital imaging and semiconductors and has its corporate offices in Waterloo, Ontario, Canada. All trademarks are registered by their respective companies. Teledyne DALSA reserves the right to make changes at any time without notice. Teledyne DALSA dls_cmos_bro_111308
Remote RadEye Product Family
Remote RadEye Product Family Overview The Remote RadEye x-ray camera provides the ultimate flexibility in design and product options for your complex imaging applications. Our unique camera design separates
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General
Endoscopy & X-Ray Image Sensors Markets
Endoscopy & X-Ray Image Sensors Markets IMAP December 2012 2012 Le Quartz - 75 cours Emile Zola - 69100 LYON-Villeurbanne Tel: +33 472 83 01 80 - Fax: +33 472 83 01 83 Web: www.yole.fr Agenda Overview
Digital Mammography Update: Design and Characteristics of Current Systems
: Design and Characteristics of Current Systems Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington AAPM Annual Meeting 2009 Anaheim,
product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology
product overview family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology scmos knowledge base scmos General Information PCO scmos cameras are a breakthrough
Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis
Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis David Bernard & Steve Ainsworth Dage Precision Industries Abstract Non-destructive testing during the manufacture of
COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS
COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen
Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1
Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1 Comparison of Amorphous Selenium and Amorphous Silicon Flat-Panel Detectors November 20, 2012 COMPARISON OF FLAT-PANEL DETECTORS 2 Abstract
College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries
2166-Handout College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 13 September - 1 October, 2010 Digital Radiography Image Parameters SNR,
Introduction to CCDs and CCD Data Calibration
Introduction to CCDs and CCD Data Calibration Dr. William Welsh San Diego State University CCD: charge coupled devices integrated circuit silicon chips that can record optical (and X-ray) light pixel =
CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging
Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through
Advantage of the CMOS Sensor
- TECHNICAL DOCUMENTATION Advantage of the CMOS Sensor Contents 1. Introduction...2 2. Comparing CCD & CMOS...2 3. CMOS Sensor Exmor...3 4. New Wide-D Technology Using High-speed Readout of the CMOS Sensor
Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology
Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology Summary The increasing customer requirements for comfort and safety and
Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators
Technical Note: 9 Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators 1- Introduction The VALIDATOR, model TN-ID-60, is a compact, and stand-alone dosimetry
WHITE PAPER. Are More Pixels Better? www.basler-ipcam.com. Resolution Does it Really Matter?
WHITE PAPER www.basler-ipcam.com Are More Pixels Better? The most frequently asked question when buying a new digital security camera is, What resolution does the camera provide? The resolution is indeed
AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM
SAMSUNG SMART DIGITAL RADIOGRAPHY 2012 Samsung Electronics All rights reserved. Samsung Electronics reserves the right to modify the design, packaging, specifications and features shown herein, without
Solar Photovoltaic (PV) Cells
Solar Photovoltaic (PV) Cells A supplement topic to: Mi ti l S Micro-optical Sensors - A MEMS for electric power generation Science of Silicon PV Cells Scientific base for solar PV electric power generation
Embedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008
Embedded Systems in Healthcare Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008 About the Speaker Working for Philips Research since 1982 Projects
Graphical displays are generally of two types: vector displays and raster displays. Vector displays
Display technology Graphical displays are generally of two types: vector displays and raster displays. Vector displays Vector displays generally display lines, specified by their endpoints. Vector display
Equipment. Lin muyan. Presented by: CocticaUwititonze Email: [email protected] Cell:+250 (0)7888 44764
Digital Medical Radiography Diagnostic (DR) system X-ray Equipment Presented by: CocticaUwititonze Email: [email protected] Cell:+250 (0)7888 44764 Lin muyan 1. Goals 2. Introduction 3. X-ray machine
Basler. Line Scan Cameras
Basler Line Scan Cameras High-quality line scan technology meets a cost-effective GigE interface Real color support in a compact housing size Shading correction compensates for difficult lighting conditions
pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps 37 500:1 > 70 % pco. low noise high resolution high speed high dynamic range
edge 4.2 LT scientific CMOS camera high resolution 2048 x 2048 pixel low noise 0.8 electrons USB 3.0 small form factor high dynamic range 37 500:1 high speed 40 fps high quantum efficiency > 70 % edge
How To Use An Edge 3.1 Scientific Cmmos Camera
edge 3.1 scientific CMOS camera high resolution 2048 x 1536 pixel low noise 1.1 electrons global shutter USB 3.0 small form factor high dynamic range 27 000:1 high speed 50 fps high quantum efficiency
Understanding Network Video Security Systems
Understanding Network Video Security Systems Chris Adesanya Panasonic System Solutions Company [email protected] Introduction and Overview This session will provide vendor neutral introduction
TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes
TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes Tektronix oscilloscopes provide several different acquisition modes. While this gives the user great flexibility and choice, each mode is optimized
Basler pilot AREA SCAN CAMERAS
Basler pilot AREA SCAN CAMERAS VGA to 5 megapixels and up to 210 fps Selected high quality CCD sensors Powerful Gigabit Ethernet interface Superb image quality at all Resolutions and frame rates OVERVIEW
White paper. CCD and CMOS sensor technology Technical white paper
White paper CCD and CMOS sensor technology Technical white paper Table of contents 1. Introduction to image sensors 3 2. CCD technology 4 3. CMOS technology 5 4. HDTV and megapixel sensors 6 5. Main differences
APPLICATION NOTE. Basler racer Migration Guide. Mechanics. www.baslerweb.com. Flexible Mount Concept. Housing
62 62 APPLICATION NOTE www.baslerweb.com Basler racer Migration Guide This paper describes what to consider when replacing the Basler L100 Camera Link or the Basler runner Gigabit Ethernet (GigE) line
Basler. Area Scan Cameras
Basler Area Scan Cameras VGA to 5 megapixels and up to 210 fps Selected high quality Sony and Kodak CCD sensors Powerful Gigabit Ethernet interface Superb image quality at all resolutions and frame rates
ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution
Product Information Version 1.0 ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution ZEISS Axiocam 506 color Sensor Model Sensor Pixel
A Breakthrough in Breast Specimen Imaging
BreAST HEALTH SOLUTIONS A Breakthrough in Breast Specimen Imaging Trident Specimen Radiography System Superb Image Quality for Streamlined Workflow The Trident system s sharp, high quality images allow
Dental Radiography Core Subject. Digital Radiography
Dental Radiography Core Subject Digital Radiography Aims: To develop an understanding of the history of digital radiography, the different types of digital x-rays and the advantages and disadvantages of
Physics testing of image detectors
Physics testing of image detectors Parameters to test Spatial resolution Contrast resolution Uniformity/geometric distortion Features and Weaknesses of Phantoms for CR/DR System Testing Dose response/signal
Digital radiography conquers the veterinary world
Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,
X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology
X- and Gamma Ray Imaging Systems based on dte-mos Detector Technology Konstantinos Spartiotis, Ray Durrant, nssi Leppänen, Henrik Lohman, Olli Männistö, Tuomas Pantsar, Jouni Pyyhtiä, Tom Schulman, Oy
Spectral Measurement Solutions for Industry and Research
Spectral Measurement Solutions for Industry and Research Hamamatsu Photonics offers a comprehensive range of products for spectroscopic applications, covering the, Visible and Infrared regions for Industrial,
Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter
Basler beat AREA SCAN CAMERAS High-resolution 12 MP cameras with global shutter Outstanding price / performance ratio High speed through Camera Link interface Flexible and easy integration Overview Convincing
Advances in scmos Camera Technology Benefit Bio Research
Advances in scmos Camera Technology Benefit Bio Research scmos camera technology is gaining in popularity - Why? In recent years, cell biology has emphasized live cell dynamics, mechanisms and electrochemical
R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.
R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction
Trigger-to-Image Reliability (T2IR)
sensors cameras frame grabbers processors software vision solutions TECHNOLOGY PRIMER Trigger-to-Image Reliability (T2IR) Learn more about: What is Trigger-to-Image Reliability (T2IR)? Understanding T2IR
APPLICATION OF APS ARRAYS TO STAR AND FEATURE TRACKING SYSTEMS
APPLICATION OF APS ARRAYS TO STAR AND FEATURE TRACKING SYSTEMS Christopher Clark, OrlyYadid-Pecht, Eric Fossum, Phil Salomon and Ed Dennison Jet Propulsion Laboratory, California Institute of Technology
Series. X-ray Inspection. www.nordsondage.com
Series X-ray Inspection www.nordsondage.com 2 Nordson DAGE Quadra X-ray Inspection Nordson DAGE Quadra X-ray Inspection 3 Nordson DAGE, the leaders in X-ray inspection for electronics, presents its 4th
Understanding Megapixel Camera Technology for Network Video Surveillance Systems. Glenn Adair
Understanding Megapixel Camera Technology for Network Video Surveillance Systems Glenn Adair Introduction (1) 3 MP Camera Covers an Area 9X as Large as (1) VGA Camera Megapixel = Reduce Cameras 3 Mega
Basler scout AREA SCAN CAMERAS
Basler scout AREA SCAN CAMERAS VGA to 2 megapixels and up to 120 fps Selected high quality CCD and CMOS sensors Gigabit Ethernet and FireWire-b interfaces Perfect fit for a variety of applications - extremely
Quality Control of Full Field Digital Mammography Units
Quality Control of Full Field Digital Mammography Units Melissa C. Martin, M.S., FACMP, FACR, FAAPM [email protected] 310-612-8127 ACMP Annual Meeting Virginia Beach, VA May 2, 2009 History of
Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections
Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections 296 Intelligent Measurement and Diagnostic Techniques for Non-destructive Inspections Fuminobu Takahashi, D. Eng. Shigeru
Optimal Vision Using Cameras for Intelligent Transportation Systems
WHITE PAPER www.baslerweb.com Optimal Vision Using Cameras for Intelligent Transportation Systems Intelligent Transportation Systems (ITS) require intelligent vision solutions. Modern camera technologies
Using visible SNR (vsnr) to compare image quality of pixel binning and digital resizing
Using visible SNR (vsnr) to compare image quality of pixel binning and digital resizing Joyce Farrell a, Mike Okincha b, Manu Parmar ac, and Brian Wandell ac a Dept. of Electrical Engineering, Stanford
High Definition Imaging
High Definition Imaging Scientific CMOS Camera Photon Technology International www.pti-nj.com Scientific CMOS Camera The new HDI camera is a breakthrough in scientific imaging cameras, due to its distinctive
Fundamentals of Photovoltaic solar technology For Battery Powered applications
Fundamentals of Photovoltaic solar technology For Battery Powered applications Solar is a natural energy source for many battery powered applications. With energy harvested from the sun, the size of batteries
DENTAL Cone beam 3D X-RAY SYSTEM with
VERSATILE INTUITIVE efficient DENTAL Cone beam 3D X-RAY SYSTEM with dedicated panoramic imaging With thirty years of experience in designing and manufacturing state-of-the-art dental panoramic and tomographic
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules Abstract J.L. Crozier, E.E. van Dyk, F.J. Vorster Nelson Mandela Metropolitan University Electroluminescence (EL) is a useful
Five Essential Components for Highly Reliable Data Centers
GE Intelligent Platforms Five Essential Components for Highly Reliable Data Centers Ensuring continuous operations with an integrated, holistic technology strategy that provides high availability, increased
Overview of Digital Detector Technology
Overview of Digital Detector Technology J. Anthony Seibert, Ph.D. Department of Radiology University of California, Davis Disclosure Member (uncompensated) Barco-Voxar Medical Advisory Board ALARA (CR
Grasshopper3 U3. Point Grey Research Inc. 12051 Riverside Way Richmond, BC Canada V6W 1K7 T (604) 242-9937 www.ptgrey.com
Grasshopper3 U3 USB 3.0 Camera Imaging Performance Specification Version 12.0 Point Grey Research Inc. 12051 Riverside Way Richmond, BC Canada V6W 1K7 T (604) 242-9937 www.ptgrey.com Copyright 2012-2015
Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:
Basler runner Line Scan Cameras High-quality line scan technology meets a cost-effective GigE interface Real color support in a compact housing size Shading correction compensates for difficult lighting
Indirect X-ray photon counting image sensor with 27T pixels and 15 electrons RMS accurate threshold
Indirect X-ray photon counting image sensor with 27T pixels and 15 electrons RMS accurate threshold B. Dierickx 1,2, B. Dupont 1,3, A. Defernez 1, N. Ahmed 1 1 Caeleste, Antwerp, Belgium 2 Vrije Universiteit
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer
The Heartbeat behind Portable Medical Devices: Ultra-Low-Power Mixed-Signal Microcontrollers
The Heartbeat behind Portable Medical Devices: Ultra-Low-Power Mixed-Signal Microcontrollers The proliferation of sophisticated yet affordable personal medical devices is transforming the health care industry,
issues Scanning Technologies Technology Cost Scanning Productivity Geometric Scanning Accuracy Total Cost of Ownership (TCO) Scanning Reliability
CISvs.CCD Scanning Technologies issues to consider before purchasing a wide format scanner Technology Cost Scanning Productivity Geometric Scanning Accuracy Total Cost of Ownership (TCO) Scanning Reliability
http://dx.doi.org/10.1117/12.906346
Stephanie Fullerton ; Keith Bennett ; Eiji Toda and Teruo Takahashi "Camera simulation engine enables efficient system optimization for super-resolution imaging", Proc. SPIE 8228, Single Molecule Spectroscopy
RVG 6500. Innovation set free.
RVG 6500 Innovation set free. Several steps ahead Introducing the RVG 6500 system the first RVG sensor to offer Wi-Fi compatibility while maintaining the same best-in-class image quality you trust. The
PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X
DIGITAL X-RAY SYSTEM with ceiling mounted tube support Universal Digital Radiographic System Conventional system, full DR components Best-in-class image quality Flexible connectivity to PACS systems General
White Paper. "See" what is important
Bear this in mind when selecting a book scanner "See" what is important Books, magazines and historical documents come in hugely different colors, shapes and sizes; for libraries, archives and museums,
Fundamentals of Cone-Beam CT Imaging
Fundamentals of Cone-Beam CT Imaging Marc Kachelrieß German Cancer Research Center (DKFZ) Heidelberg, Germany www.dkfz.de Learning Objectives To understand the principles of volumetric image formation
Distributed Temperature Sensing - DTS
Intelligent Solutions Distributed Temperature Sensing - DTS Enabling fast, reliable and cost-effective sensing through highly integrated optical measurement systems Fire detection Power cable monitoring
Data. microcat +SPECT
Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for
Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note
Keysight Technologies Using Fine Resolution to Improve Thermal Images Application Note Introduction Digital imaging opened up new possibilities and has been very much part of our lives since social media
White Paper. The Next Generation Video Codec Scalable Video Coding (SVC)
White Paper The Next Generation Video Codec Scalable Video Coding (SVC) Contents Background... 3 What is SVC?... 3 Implementations of SVC Technology: VIVOTEK as an Example... 6 Conclusion... 10 2 Background
Séries U3-CMOS. Nouvelles. Caméras Numériques USB3. Ultra rapides
Séries U3-CMOS Nouvelles Caméras Numériques USB3 Ultra rapides 1 Cette nouvelle série de caméras pour la microscopie et adaptée à un grand nombre d applications. 2 Fabrications et contrôles en salles blanches
Checklist for the Qualification of Digital Detector Array Systems
Paper No. 010-12 Checklist for the Qualification of Digital Detector Array Systems 1 February 2012 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
MEDICAL IMAGING. 90/30 Remote Controlled RF System
MEDICAL IMAGING 90/30 Remote Controlled RF System The Easy solution for your Remote Controlled room Apollo EZ represents the Easy approach for the radiographic/fluoroscopic room and it comes from the experience
EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams
EPEX Direct-to-Digital System for General Radiography Featuring... Versatility for a complete range of general radiographic exams The Hologic EPEX General Radiography System is a direct-to-digital, fully
Mikro-Tasarım Next Generation Imaging Sensors
Mikro-Tasarım Next Generation Imaging Sensors NIR SWIR High- Performance ROICs, Sensors, and ASICs for Infrared Imaging Systems LWIR Mikro- Tasarım was founded in 2008 as a fabless semiconductor IC design
Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations Andrew P. Smith, Ph.D.
Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations Andrew P. Smith, Ph.D. Introduction Screen-film image receptors have been the standard detector used in conventional
Industrial vision cameras CAMERA LINK DVI-D FULL HD CAMERA LINE
Industrial vision cameras CAMERA LINK DVI-D FULL HD CAMERA LINE CAMERA LINK DVI-D FULL HD CAMERA LINE 12.000.000 PIXEL WITH 25 FRAMES PER SECOND Since 1996 NET distributes teli cameras. High-speed output
EVA. Digital X-Ray System. Exceptional Image Quality Ideal For Any Practice Full Integration Best Supported Sensor Great Value
EVA Digital X-Ray System Exceptional Image Quality Ideal For Any Practice Full Integration Best Supported Sensor Great Value ImageWorks Generations of Imaging www.imageworkscorporation.com Generations
AngiX III FD Boost your confidence beyond the clinical. gehealthcare.com
AngiX III FD Boost your confidence beyond the clinical gehealthcare.com Boost your confidence beyond the clinical If you re considering investing in a system to do cardiovascular procedures, think beyond
Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate
Basler racer Line Scan Cameras Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate Flexible and easy integration, supported by a very compact design Low power consumption
Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP
Now Powered by LightField FEATURES BENEFITS Back Illuminated CCD (248B) For highest sensitivity Front illuminated CCD (248F) Affordable technology for moderate light level applications Ultra low noise
REGIUS History. Touch REGIUS110. REGIUS170 ImagePilot REGIUS150 REGIUS330 CS-1
Konica Minolta has been a CR technology leader since 1996, consistently designing, developing, and delivering innovative solutions. The REGIUS Σ represents the sum of this experience. REGIUS Σ delivers
The Fundamentals of MTF, Wiener Spectra, and DQE. Motivation
The Fundamentals of MTF, Wiener Spectra, and DQE Robert M Nishikawa Kurt Rossmann Laboratories for Radiologic Image Research Department of Radiology, The University of Chicago Motivation Goal of radiology:
MACHINE VISION FOR SMARTPHONES. Essential machine vision camera requirements to fulfill the needs of our society
MACHINE VISION FOR SMARTPHONES Essential machine vision camera requirements to fulfill the needs of our society INTRODUCTION With changes in our society, there is an increased demand in stateof-the art
Smart Data Center Solutions
Smart Data Center Solutions New Data Center Challenges Require New Solutions Data Center Architecture. Inside and Out. Data centers are mission-critical facilities. A silo-based approach to designing,
Coronis 5MP Mammo. The standard of care for digital mammography
Coronis 5MP Mammo The standard of care for digital mammography The standard of care For thousands of women every day, details make all the difference. This understanding, along with many years of commitment
A 10,000 Frames/s 0.18 µm CMOS Digital Pixel Sensor with Pixel-Level Memory
Presented at the 2001 International Solid State Circuits Conference February 5, 2001 A 10,000 Frames/s 0.1 µm CMOS Digital Pixel Sensor with Pixel-Level Memory Stuart Kleinfelder, SukHwan Lim, Xinqiao
INTRODUCTION. A. Purpose
New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programs Computed Radiography INTRODUCTION A. Purpose This guide describes
Fundamentals of Photovoltaic Materials
Fundamentals of Photovoltaic Materials National Solar Power Reasearch Institute, Inc. 12/21/98-1 - 12/21/98 Introduction Photovoltaics (PV) comprises the technology to convert sunlight directly into electricity.
Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW
Qiang Lu Chapter 3. System Scanning Hardware Overview 79 Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Since all the image data need in this research were collected from the highly modified AS&E 101ZZ system,
Data Center Solutions
Data Center Solutions New Data Center Challenges Require New Solutions Data Center Architecture. Inside and Out. Data centers are mission-critical facilities. A silo-based approach to designing, deploying
I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit
I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete
Development of a high-resolution, high-speed vision system using CMOS image sensor technology enhanced by intelligent pixel selection technique
Development of a high-resolution, high-speed vision system using CMOS image sensor technology enhanced by intelligent pixel selection technique Kenji Tajima *a, Akihiko Numata a, Idaku Ishii b a Photron
The Dusk of FireWire - The Dawn of USB 3.0
WWW.LUMENERA.COM The Dusk of FireWire - The Dawn of USB 3.0 Advancements and Critical Aspects of Camera Interfaces for Next Generation Vision Systems WHAT S INSIDE Executive Summary Criteria for Selecting
Page: 1 of 6 Page: 1 of 6
Page: 1 of 6 Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique