Service & Support. How can you establish a connection between an S7-1200 PLC and SIMATIC NET OPC? S7-1200 PLC, SIMATIC NET OPC.



Similar documents
Service & Support. How can you establish a connection between a S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

FAQ Communication over IE

TECHNICAL NOTE TNOI34

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

S7 OPC Server Tutorial

1 Application Description Objective Goals... 3

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

Profinet to EDV111 Series LED Signs Siemens Function Block Software Manual

FAQ about Drive Technology

HTML Code Generator V 1.0 For Simatic IT Modules CP IT, IT, IT

1 Application Description System Topology Hardware and Software Requirements... 3

The goal is to program the PLC and HMI to count with the following behaviors:

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Service & Support. How do you synchronize the time of the HMI Basic Panel with a S PLC? S PLC, HMI Basic Panel.

How-To-Do. Hardware Configuration SLIO CPU 014

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

PROFINET IO Diagnostics 1

SIMATIC Expert Communication Connecting S7-400H to PC Station (WinCC)

8/23/13 Configuring the S7 I/O Server for Windows 95 to Access S7 PLCs Via the Profibus Network

8/23/13 Configuring the S7 Server for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP1613 Card for ISO (Industrial Ethernet)

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

Cover PROFINET IO. Code Reader System SIMATIC MV440 / MV420. FAQ June Service & Support. Answers for industry.

SIMATIC NET. Step by Step: Ethernet Communication between OPC Server and S7-200 incl. CP Overview and Environment. Contents

FAQ Communication over IE


SIMATIC PCS 7. SIMATIC Maintenance Station PDM A stand-alone Solution. Siemens AG All Rights Reserved.

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

SIMATIC PDM V6.0. Getting Started Edition 12/2004

Service & Support. How do you configure time synchronization using the NTP procedure (without SICLOCK) for small PCS 7 plants?

Cover sheet PROFINET IO. SIMATIC MV440 Code Reading System. FAQ February Service & Support. Answers for industry.

Installing a Browser Security Certificate for PowerChute Business Edition Agent

How many high-speed counters (HSCs) are provided by the SIMATIC S PLC? SIMATIC S FAQ March Service & Support. Answers for industry.

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

DCOM Setup. User Manual

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

DEPLOYING A VISUAL BASIC.NET APPLICATION

Service & Support. How Can You Have Diagnostics Data of IPCs Displayed in WinCC? WinCC, IPC and DiagMonitor. FAQ July Answers for industry.

Service & Support. How do you create a communication of VNC with an Industrial Thin Client SIMATIC ITC? Thin Client.

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato

Symantec Enterprise Vault

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

1 How configure S7 PLC in the configuration tool

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

Configuring the SST DeviceNet OPC Server

BASLER ACE QUICK INSTALLATION GUIDE

IGSS. Interactive Graphical SCADA System. Quick Start Guide

S SIMATIC S Welcome. Automation task. Hardware section 2. Software section 3. Security. Getting Started 05/2014 A5E AC

S7 for Windows S7-300/400

Applications & Tools. Migration to TIA Portal. WinCC Basic / Comfort / Advanced STEP 7 V5.x / WinCC flexible 2008 SP3. Migration Guide September 2013

Service & Support. How do you create a communication of RDP with an Industrial Thin Client SIMATIC ITC? Thin Client.

MS830 / MS833 Barcode Reader v1.0 9-December-2014

Changing Your Cameleon Server IP

Recommended Network Setup

How-To-Do. EtherCAT Communication with CPU 300S

XStream Remote Control: Configuring DCOM Connectivity

CMP-102U. Quick Installation Guide

Applications & Tools. Remote Control Concept with SCALANCE S Modules over IPsec-secured VPN Tunnel SCALANCE S. Application Description February 2010

Tech Tips Helpful Tips for Pelco Products

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

28 What s New in IGSS V9. Speaker Notes INSIGHT AND OVERVIEW

Windows Vista / Windows 7 Installation Guide

Connecting the DG-102S VoIP Gateway to your network

Loyalty Program Guide

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

Continuous PROFIBUS PA Instruments and Step 7. Configuring a Siemens Continuous Level PROFIBUS PA device in a S7-300 or S7-400 PLC

DB Administration COMOS. Platform DB Administration. Trademarks 1. Prerequisites. MS SQL Server 2005/ Oracle. Operating Manual 09/2011

Video Administration Backup and Restore Procedures

Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2

How to Program a Commander or Scout to Connect to Pilot Software

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Technical Information Sheet Page 1 of 8

HP ProLiant DL380 G5 High Availability Storage Server

Quick Guide: Troubleshooting Info from SNAP PAC Systems

How to install USB driver (MICRO/I)

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A5. PLC-Simulation with S7-PLCSIM

SIMATIC. Working with STEP 7 V5.1. Important Notes, Contents. Introduction to STEP 7. The SIMATIC Manager. Programming with Symbols

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

Service & Support. Higher-level safe switch-off of the power supply of functionally nonsafe standard modules? Wiring Examples.

Flexi Soft Ethernet IP: Implicit Messaging with a Omron PLC

TRIAL SOFTWARE GUIDE 1. PURPOSE OF THIS GUIDE 2. DOWNLOAD THE TRIALSOFTWARE 3. START WIDS 4. OPEN A SAMPLE COURSE, PROGRAM

Operating Instructions

Importing Contacts to Outlook

Downloading Driver Files

Automation License Manager

Windows XP Home Edition / Windows XP Professional

Application Note Siemens PLC and SIMATIC STEP 7 / TIA Portal

USB Driver Installation for Windows XP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE C2. High Level Programming with S7-SCL

Colligo Contributor File Manager 4.6. User Guide

Remote Access for Siemens S7-300 & 400 PLCs, and their VIPA equivalents S300 SPEED7.

EnGenius ERB M Range Extender. Quick Start Guide

Transcription:

Cover How can you establish a connection between an S7-1200 PLC and SIMATIC NET OPC? S7-1200 PLC, SIMATIC NET OPC FAQ January 2010 Service & Support Answers for industry.

This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply. Clicking the link below directly displays the download page of this document: http://support.automation.siemens.com/ww/view/en/39960679 Question Answer How can you establish a connection between an S7-1200 PLC and SIMATIC NET OPC? The instructions and notes listed in this document provide a detailed answer to this question. 2 Version 1.0, Item-ID: 39960679

Table of contents Table of contents 1 Introduction... 4 1.1 Use case... 4 1.2 Requirements... 4 2 Setting up your S7-1200 PLC using STEP 7 Basic... 5 2.1 Hardware configuration... 5 2.2 Software configuration... 8 2.3 Finalize the S7-1200 PLC work... 10 3 Create and configure the PC-Station... 12 3.1 Create a new STEP 7 project... 12 3.2 Add a SIMATIC PC station... 12 3.3 Add an OPC server... 13 3.4 Add an Ethernet interface IE General... 15 3.5 Save and compile the PC-Station... 17 3.6 Setup the Station Configurator... 17 3.6.1 Open from the Start menu... 17 3.6.2 Insert the OPC Server and the IE General... 17 3.7 Set the PG/PC interface... 18 3.8 Download the hardware configuration... 19 4 Configure the network with NetPro... 21 4.1 Create an S7-connection... 21 4.2 Configure an S7-connection... 22 4.3 Compile the project... 22 5 OPC Scout... 24 5.1 Create a new group... 24 5.2 Select the connection and create the items... 24 5.3 View the values... 25 Version 1.0, Item-ID: 39960679 3

1 Introduction 1 Introduction 1.1 Use case As it is not possible to create a PC Station with STEP 7 Basic V10.5, you need to use one of the following tools: SIMATIC NCM PC tool of SIMATIC NET Edition 2008 SIMATIC MANAGER V5.4 SP5 Figure 1-1 1.2 Requirements PG/PC STEP 7 Basic V10.5 SIMATIC MANAGER V5.4 SP5 or SIMATIC NET Edition 2008 NCM PC tool OPC Server OPC Scout S7-1200 PLC Ethernet Cable Figure 1-2 4 Version 1.0, Item-ID: 39960679

2 Setting up your S7-1200 PLC using STEP 7 Basic 2 Setting up your S7-1200 PLC using STEP 7 Basic Configure your S7-1200 PLC and provide data to be monitored via an OPC connection. 2.1 Hardware configuration For the hardware configuration, use the project view of STEP 7 Basic V10.5. Create the project Select the menu command "Project > New". The dialog box "Create a new project" opens. Enter the name "S7-1200_OPC_SIMATIC-NET" in the "Project name" input field. Click the "Create" button. Figure 2-1 Version 1.0, Item-ID: 39960679 5

2 Setting up your S7-1200 PLC using STEP 7 Basic Add a new PLC to the project Double-click the project tree command Add new device. The Add new device dialog box opens. In the work area, click the SIMATIC PLC button, and select your PLC by clicking its MLFB. Click the OK button. Figure 2-2 6 Version 1.0, Item-ID: 39960679

2 Setting up your S7-1200 PLC using STEP 7 Basic Change the IP address of the Ethernet port Double-click the project tree command Devices & Networks. In the Devices & Networks work area, click the Ethernet port of your S7-1200 PLC. In the navigation area of the Properties tab, select the Ethernet addresses instruction. Define the IP address 192.168.0.110 for the Ethernet port in the IP address input field. Click the Add new subnet button. In the Devices & Networks work area, you will find the subnet PN/IE_1 connected to your S7-1200 PLC. Figure 2-3 Version 1.0, Item-ID: 39960679 7

2 Setting up your S7-1200 PLC using STEP 7 Basic 2.2 Software configuration To see value changes, you will now create a small program in which two hardware inputs and a hardware output of your PLC are connected to a software flip-flop. Add a global data block In the Project tree, click the expand button of your PLC folder (for example, PLC_1 [CPU 12 ]). Open the Program blocks sub-folder by clicking its expand button, and double-click the Add new block instruction. In the Add new block dialog box, select the Data block (DB) button, enter the name Data_block_1 in the Name input field, and uncheck the Symbolic access only check box. Click the OK button. The Data_block_1 work area opens. Figure 2-4 8 Version 1.0, Item-ID: 39960679

2 Setting up your S7-1200 PLC using STEP 7 Basic Create static data in a global data block Create a "Bool" data type tag named static_01 in the Data_block_1 work area. Figure 2-5 Create a program in Main [OB1] In the Program blocks folder of your PLC, double-click the Main [OB1] instruction. Copy the program shown in the next picture. You will find the bit logic operations in the Bit logic folder in the Instructions pane on the Instructions task card. Drag n Drop the Normally open contacts, the Output coil, and the Set/Reset flip-flop into Network 1 of your Main [OB1] work area, according to the picture shown below. Make sure that the input fields are configured in the same way as shown in the picture and in the table. Figure 2-6 Contacts Table 2-1 SR FlipFlop input S: normally open contact I1.0 SR FlipFlop input R: normally open contact I1.1 SR tag DB1.DBX0.0 SR FlipFlop output Q: output coil Q1.0 Version 1.0, Item-ID: 39960679 9

2 Setting up your S7-1200 PLC using STEP 7 Basic Note: The % in front of the addresses is added by STEP 7 Basic V10.5 automatically. 2.3 Finalize the S7-1200 PLC work Highlight the PLC_1 [CPU12 ] folder in your project tree in order to compile, download, and run your S7-1200 PLC. Compile and download the program Press the Download to device button in the Toolbar. Figure 2-7 The Extended download to device dialog box opens. Ensure that the selected PG/PC interface and subnet are correct. Select PLC_1. Click the Load button. Figure 2-8 If you have downloaded your project before, the load preview dialog box may open instead of the Extended download to device dialog box. 10 Version 1.0, Item-ID: 39960679

2 Setting up your S7-1200 PLC using STEP 7 Basic Another dialog box may open, asking to stop the S7-1200 PLC for downloading. Acknowledge by clicking the OK button. Figure 2-9 The load preview dialog box opens. Click the Load button. Figure 2-10 Switch the S7-1200 PLC to run The load result dialog box opens. Check the Start all check box, and press the Finish button. Your S7-1200 PLC status LED changes from stop to run. Figure 2-11 Version 1.0, Item-ID: 39960679 11

3 Create and configure the PC-Station 3 Create and configure the PC-Station To access the data in your S7-1200 PLC via OPC, you have to create and configure an S7-connection in a STEP 7 project with the SIMATIC MANAGER tool or with the SIMATIC NCM PC tool. The following description refers to the SIMATIC MANAGER tool. 3.1 Create a new STEP 7 project Open your SIMATIC MANAGER tool. To create a new STEP 7 project, click the menu command File > new. The New Project dialog box opens. Write S7-1200_OPC-Test in the Name input field. Click the OK button. Figure 3-1 3.2 Add a SIMATIC PC station Click the menu command Insert > station > SIMATIC PC-Station. A SIMATIC PC- Station is added to your project. Figure 3-2 12 Version 1.0, Item-ID: 39960679

3 Create and configure the PC-Station 3.3 Add an OPC server Select the OPC server Select the SIMATIC PC-Station in the project tree, and click the menu command Edit > Open Object. The HW Config dialog box opens. Figure 3-3 Click line number one of the (0) PC rack in the work area. Double-click SIMATIC PC-Station > User Application > OPC Server > SW V7 in the catalog. The OPC server is inserted into line number one of the rack. Figure 3-4 Version 1.0, Item-ID: 39960679 13

3 Create and configure the PC-Station Configure the OPC server properties Double-click the OPC Server module in line number one of the (0) PC rack. The Properties dialog box opens. Click the S7 tab. Set the Use Symbols radio button to None. Click the OK button. Note: Symbol use is not supported by S7-1200 PLCs. Figure 3-5 14 Version 1.0, Item-ID: 39960679

3 Create and configure the PC-Station 3.4 Add an Ethernet interface IE General Select the Ethernet interface Click line number two of the (0) PC rack in the work area. Double-click SIMATIC PC-Station > CP Industrial Ethernet > IE General > SW V6.2 SP1 in the catalog. Figure 3-6 The Properties dialog box opens. Version 1.0, Item-ID: 39960679 15

3 Create and configure the PC-Station Enter the IP address In the Parameters tab, enter the IP address of your PC in the IP address input field (for example, 192.168.0.11). Figure 3-7 Add a subnet to the Ethernet Interface Click the New button. The Properties dialog box for a new subnet opens. Figure 3-8 Click the OK button. The subnet properties dialog box closes. Click the OK button. The Ethernet interface properties dialog box closes. The Ethernet interface is inserted into line number two of the rack. 16 Version 1.0, Item-ID: 39960679

3 Create and configure the PC-Station 3.5 Save and compile the PC-Station Click the menu command Station > Save and Compile. Figure 3-9 3.6 Setup the Station Configurator 3.6.1 Open from the Start menu Double-click the Station Configurator symbol in the task bar. The Station Configuration Editor window opens. Figure 3-10 3.6.2 Insert the OPC Server and the IE General Click the Add button. The Add Component dialog box opens. Select OPC Server as the component type for Index 1, and click the OK button. Acknowledge any dialog box that opens. Add IE General as the component type for Index 2. Close the Station Configurator Editor dialog box by clicking the OK button. Version 1.0, Item-ID: 39960679 17

3 Create and configure the PC-Station Figure 3-11 Ignore any warning and proceed by clicking the OK button. The import is finished. 3.7 Set the PG/PC interface Click the menu command Options > Set PG/PC Interface. The dialog box opens. Figure 3-12 18 Version 1.0, Item-ID: 39960679

3 Create and configure the PC-Station Assign the interface parameter to PC internal (local) and click the OK button. Figure 3-13 3.8 Download the hardware configuration Make sure that your S7-1200 PLC is connected to your PG/PC. Open your SIMATIC MANAGER project. Select the SIMATIC PC Station in the project tree, and click the menu command Edit > Open Object. The HW Config dialog box opens. Figure 3-14 Version 1.0, Item-ID: 39960679 19

3 Create and configure the PC-Station Click the Download button in the tool bar. Acknowledge the Select Target Module dialog box by clicking the OK button. The Select Node Address dialog box opens. Figure 3-15 Ensure that the IP address of your SIMATIC PC-Station(1) matches the IP address of your PC. Click the OK button. Figure 3-16 20 Version 1.0, Item-ID: 39960679

4 Configure the network with NetPro 4 Configure the network with NetPro 4.1 Create an S7-connection Click the menu command Options > Configure Network. The NetPro window opens. Figure 4-1 Select the OPC server slot of the PC-Station(1). Click the menu command Insert > New Connection. The Insert New Connection dialog box opens. Figure 4-2 Since the S7-1200 PLC is an S7 Station, we are able to use an S7-Connection. The partner should be unspecified since the S7-1200 is not available in the same STEP 7 project. Click the OK button. The Properties - S7 connection dialog box opens. Version 1.0, Item-ID: 39960679 21

4 Configure the network with NetPro 4.2 Configure an S7-connection Enter the IP address 192.168.0.110 of your S7-1200 PLC in the Partner Address input field of the Properties - S7 connection dialog box. Click the Address Details button. The Address Details dialog box opens. Enter 0 in the Partner Rack input field and 1 in the Partner Slot input field. Click the OK button. Close the Properties - S7 connection dialog box by clicking its OK button. Close the Insert New Connection dialog box by clicking its OK button. Figure 4-3 4.3 Compile the project Click the menu command Network > Save and Compile. Figure 4-4 22 Version 1.0, Item-ID: 39960679

4 Configure the network with NetPro Download the connection Select the SIMATIC PC Station (1). Download the connection to the SIMATIC PC Station (1) by clicking the Download button. Acknowledge any dialog box that opens. The connection should now be downloaded to your device. Figure 4-5 Version 1.0, Item-ID: 39960679 23

5 OPC Scout 5 OPC Scout 5.1 Create a new group Open OPC Scout. Double-click OPC.SimaticNET in the server tree. The Add Group dialog box opens. Enter S7-1200_OPC_Test in the Group Name input field. Click the OK button. Figure 5-1 5.2 Select the connection and create the items Double-click the new group S7-1200_OPC_Test. The OPC - Navigator dialog box opens. Figure 5-2 Browse the Nodes tree to Connections > \S7 > S7 connection_1 > objects > I > [New Definition]. Double-click the option [New Definition]. The Define New Item dialog box opens. Fill in the data as shown in the Table 5-1: Table 5-1 Datatype Address Bit No. No. Values X 1 0 1 24 Version 1.0, Item-ID: 39960679

5 OPC Scout Click the OK button. Move the new item to the right column four times by clicking the --> button. Double-click on each item, and modify its name as shown in Table 5-2: Table 5-2 S7:[S7 connection_1]ix1.0 S7:[S7 connection_1]ix1.1 S7:[S7 connection_1]db1, X0.0, 1 S7:[S7 connection_1]qx1.0 Click the OK button to end the OPC Navigator window. 5.3 View the values In the Value column, you can see the actual values of the listed items. If you are connected to your S7-1200 PLC, the Quality of the item is listed as good. Figure 5-3 Version 1.0, Item-ID: 39960679 25