Comm5 Wiring Installation



Similar documents
Specification SFTP CAT6 Network Cable 23AWG CU

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Grounding and Shield Termination. Application Note 51204

Technical Description U00980 Revision 2

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Modular I/O System Analog and Digital Interface Modules

RS485 & RS422 Basics

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Square D Clipsal C-Bus Network Analyzer

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

ENCL-MZ800-WAL ENCL-MX800-PAN MNL TAC I/A Series MicroNet MN 800 Series Controller Installation Instructions. Application.

MNL-10Rxx Series MNL-15Rxx Series MNL-20Rxx Series

AC and DC Drive System Installation Information

AutoRanging Digital MultiMeter

Screened cable and data cable segregation

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Standards Affecting a Premise T-1 Installation

AC-DC Converter Application Guidelines

E2 Controller Wiring Practices Rev 4 19-APR-2010

ABR Brake Rectifier Instruction Manual

T7560A,B,C Digital Wall Module

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

ADACSNET USB Control Module

How To Fix A Cbus Network From A Power Supply To A Power Source

PART 1 - INTRODUCTION...

UniStream CPU-for-Panel

Video Camera Installation Guide

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Product Catalog BAS-PRC010-E4. Tracker Version 12 Building Automation System. August 2010

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

Communication, Signal & Data Cables

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Current Probes. User Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

with Component Rating A Simple Perspective

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

User's Guide. True RMS Industrial Multimeter

Standard Buccaneer - Ethernet

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

HSG Engineering Tech Bulletin

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

PERF10 Rubidium Atomic Clock

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

MCR1900 Media Converter 19-Slot Chassis

E Series. E Series. Category 6 and 5e. Features

Crosstalk effects of shielded twisted pairs

How to Choose the Right Cable Category

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

Manual Ranging MultiMeter

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Technical Note Series

Tracker. Tracker Version 12 Building Automation System BAS-PRC010-EN. March 2008

Achat 115MA full-range speaker. user manual

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Quick Design & Install Guide. Computerised Emergency Evacuation System LONWORKS TM Powerline Technology

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Cable Solutions for Servo and Variable Frequency Drives (VFD)

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Cisco Integrated 4G Low-profile Outdoor Saucer Antenna (ANT-4G-SR-OUT-TNC)

Installation & Weatherproofing Guide for ENCOM Broadband Radios

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

GenTech Practice Questions

Provides one channel for Ethernet over existing

QSE-CI-DMX Control Interface

BACnet Wiring Guidelines. For Price Controls MANUAL INSTALLATION

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

How To Buy Honeywell Genesis Series Fire Alarm Cables

Networks. The two main network types are: Peer networks

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

LocoNet, the Digitrax Difference

LMR8TT Mini 10BASE-T Hub/Repeater

MYTHBUSTING Takes on Shielded Cabling

FlexPoint T1/E1 Copper to Fiber Line Driver

Model CFA-24 Transparent Cable Farm Automation Switch

Power supply unit Model: PAC-SC50KUA

CX Zoner Installation & User Guide

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

AC 800M EtherNet/IP DeviceNet Installation

BACnet Automation Interface Module (Network Version)

STRANDED AND SOLID CONDUCTOR

Outside Telephone Cable

VDSL2 POTS Splitters and Microfilters

Security & Control Cables

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

Operating Instructions

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Transcription:

Comm5 Wiring Installation This wiring information applies to the following Trane products: Tracer Summit systems (Comm5 communications, Version 12.0 and higher) Tracker systems (BMTK models) Tracer loop controller systems Tracer MP580/581 systems BAS-SVN01A-EN June 2003

Notice: Warnings and Cautions appear at appropriate sections throughout this manual. Read these carefully. WARNING Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION Indicates a situation that may result in equipment or property-damageonly accidents. Conventions used: The following notifications and formats may appear at appropriate locations throughout this guide. IMPORTANT Alerts installer, servicer, or operator to potential actions that could cause the product or system to operate improperly but will not likely result in potential for damage Note: A note may be used to make the reader aware of useful information, to clarify a point, or to describe options or alternatives. This symbol precedes a procedure that consists of only a single step. The following are trademarks or registered trademarks of their respective companies: Lon- Talk from Echelon Corporation; Rover, Tracer, Tracer Summit, Tracker, Trane, and VariTrac from Trane. 2003 American Standard Inc.

Wiring and topology recommendations Comm5 is Trane s implementation of LonTalk. Trane has updated its recommendations for Comm5 wiring and topology. These recommendations are different than originally published Comm5 installation practices. The following information summarizes the wiring and topology recommendations: Use 22 AWG Level 4 unshielded communication wire for most Comm5 installations. Use shielded Level 4 wire for all communication wiring on the Vari- Trac central control panel (CCP). See Specifications for Level 4-compliant cables on page 11. Limit Comm5 links to 4,500 ft and 60 devices maximum (without a repeater). Use the following termination resistors on all links: 105 Ω at each end for Level 4 wire 82 Ω at each end for Trane purple wire Use daisy chain topology. Limit zone sensor communication stubs to 8 per link, 50 ft each maximum. Use one repeater for an additional 4,500 ft, 60 devices, and 8 communication stubs. Recommended wiring practices To ensure proper network communication, follow these recommended wiring and planning guidelines when installing communication wire: All wiring must comply with the National Electrical Code (NEC) and local codes. Although Comm5 does not require polarity sensitivity, Trane recommends keeping polarity consistent throughout the site. Make sure that 24 Vac power supplies are consistent in how they are grounded. Avoid sharing 24 Vac between Comm5 controllers. Avoid overtightening cable ties and other forms of cable wraps. This can damage the wires inside the cable. Do not run Comm5 cable alongside or in the same conduit as 24 Vac power. This includes the conductors running from triac-type inputs. In open plenums, avoid running wire near lighting ballasts, especially those using 277 Vac. Use a daisy chain configuration. Use termination resistors as described in resistance placement for Comm5 links on page 5. Insulate termination-resistor leads. Use only one type of communication wire; do not mix different types of wire. BAS-SVN01A-EN 3

Wiring requirements The recommended Comm5 communication-link wiring is 22 AWG, Level 4, twisted-pair wire. See Specifications for Level 4-compliant cables on page 11. The wire can be either shielded or unshielded. However, unshielded wire is recommended for most installations. You can also use low capacitance, 18 AWG, shielded, twisted-pair with stranded, tinned-copper conductors (Trane purple wire). The maximum wire length for Comm5 communication links is 4,500 ft (1,400 m). Comm5 communication-link wiring must be installed in a daisy-chain configuration (Figure 1 and Figure 2 on page 4). Figure 1. Daisy chain configuration System Panel Figure Note: Maximum wire length for Comm5 is 4,500 ft (1,400 m) (Comm5 wire length limitations can be extended through the use of a link repeater; see Comm5 physical link repeater on page 6.) For termination resistor placement, see resistance placement for Comm5 links on page 5. Figure 2. Alternate daisy chain configuration Repeater System panel Figure Note: The system panel may be placed in the middle of the link. Maximum wire length for Comm5 is 4,500 ft (1,400 m) on each side of the repeater For termination resistor placement, see resistance placement for Comm5 links on page 5. 4 BAS-SVN01A-EN

resistance placement for Comm5 links resistors are required at each end of Comm5 communication daisy chain links. To correctly place termination resistors, follow these guidelines: Terminate a daisy chain configuration with a resistor at each end of the link (Figure 3): 22 AWG, Level 4 wire, 105 Ω, 1%, ¼ W 18 AWG, Trane purple wire, 82 Ω, 1%, ¼ W If a repeater is used, each link of the configuration that is created by the repeater requires termination resistors (Figure 4 on page 6). Trane recommends that only one type of wire be used for the Comm5 communication link. Make a set of as-built drawings or a map of the communication wire layout during installation. Any sketch of the communication layout should feature the termination resistor placement. Figure 3. Daisy chain resistor placement System panel resistor resistor Figure Note: Use 105 Ω, 1%, ¼ W for 22 AWG, Level 4. Use 82 Ω, 1%, ¼ W for 18 AWG, Trane purple wire. BAS-SVN01A-EN 5

Figure 4. Alternate daisy chain resistor placement resistors resistors Repeater System panel Figure Note: Maximum wire length for the entire configuration is 4,500 ft (1,400 m). Comm5 wire length limitations can be extended through the use of a link repeater, see Comm5 physical link repeater. Comm5 physical link repeater A Comm5 link repeater regenerates the signal on a Comm5 link. The configurations on either side of the repeater should be daisy chain. Both link segments require proper termination (Figure 4). Link repeater requirements A link repeater is required when: The total wire length is greater than the maximum wire run length of 4,500 ft (1,400 m). More than 60 devices are connected to a link This total does not include the BCU, the link repeater, and the temporary use of a service tool on the same link. More than eight zone sensor communication stubs (maximum 50 ft) are required on a Comm5 link See Comm5 zone sensor comm jack on page 9. Link repeater guidelines Follow these guidelines when using link repeaters: Use only one link repeater on a link. Note: Use a repeater to double the maximum allowable wire length. For example, when a repeater is used with a daisy chain configuration, the total wire length can be 9,000 ft (3,800 m) (with half the wire length on either side of the repeater). 6 BAS-SVN01A-EN

Limit the link repeater to 60 devices on either side of the link. Use an earth ground with the link repeater. Make sure the installer is aware of this before making any power connections. Link repeater connections The recommended shield connections are shown in Figure 5. Use these connections for instances where shielded communication wire is used. For an example of using a repeater to create an extended daisy chain configuration, see Figure 6 on page 8. Follow these guidelines when using a repeater: Read the Comm5 repeater installation (3270 3285) information that comes with the link repeater. For information about terminating daisy chain configurations, see resistance placement for Comm5 links on page 5. Connect shield-drain wires entering the repeater to a terminal marked with a capacitor symbol. The entering shield-drain wire must be connected to earth ground at the system panel. Connect shield-drain wires leaving the repeater to the repeater terminal marked with an earth ground symbol. Figure 5. Comm5 shield repeater connection Line voltage To earth ground 24 Vac Transformer by others Link repeater Entering shield (Coming from the system panel) Leaving shield should be connected to earth ground BAS-SVN01A-EN 7

Figure 6. Comm5 daisy chain repeater connection and shielded wire System panel 105 Ω/82 Ω** resistor Comm Shield Splice* Splice* 105 Ω/82 Ω** resistor Link repeater 24 Vac Comm 105 Ω/82 Ω** resistor Splice* Comm 105 Ω/82 Ω** resistor Splice* Figure Note: * A continuous shield is required when shielded wire is used. At each controller, splice shield wire and tape back to prevent grounding. Connect shield wire to earth ground at system panel and repeater. If unshielded communication wire is used, no shield connections are necessary. **The value of the termination resistor is dependent on the wire type: 105 Ω for 22 AWG, Level 4 wire and 82 Ω for 18 AWG, Trane purple wire. 8 BAS-SVN01A-EN

Figure 7. Communication stubs used with a repeater Comm5 zone sensor comm jack Many Trane zone sensor models include a communication jack. When properly wired to the communication terminals on the unit controller, the communication jack provides easy access to both the controller and the entire Comm5 link. This access enables you to view and modify the status and configuration information of any controller on the link using the Rover service tool. The recommended wire between the controller and the communication jack is 22 AWG, Level 4 wire; or 18 AWG shielded, twisted-pair with stranded, tinned-copper conductors (Trane purple wire). Thermostat wire is not recommended for the communication jack. Zone sensor communication stubs The wire that runs between the controller and zone sensor is commonly referred to as the communication stub. Figure 7 shows an example of communication stubs on a Comm5 link when a repeater is used. Note: Only eight stubs can be used per Comm5 link. To add more stubs to the link, use a repeater. Up to eight stubs may be used on each side of the repeater (16 total stubs). Each communication stub must not exceed 50 ft in length. System panel Repeater Comm stub Comm stub Figure Note: Maximum wire length on either side of the repeater is 4,500 ft (1,400 m). The link repeater is limited to 60 devices on either side of the link. Place termination resistors at the end of each link. Use a 105 Ω resistor at each end of the link for Level 4 wire and an 82 Ω resistor for Trane purple wire. BAS-SVN01A-EN 9

Verifying communication status The information in this section will help you to interpret the Comm lightemitting diode (LED) on the Comm5 system panel. The yellow Comm LED indicates the communication status of the Comm5 controller. Table 1 describes Comm LED activity. Table 1. Yellow Comm LED LED activity LED is off continuously LED blinks LED is on continuously Explanation The controller is not detecting any communication (normal for stand-alone applications). The controller detects communication (normal for communicating applications). This is a condition that may occur during discovery. The LED may flash fast enough to look as if it is on continuously. If this LED activity occurs at any other time, the site may have excessive radio frequency interference (RFI). 10 BAS-SVN01A-EN

Table 2. Cable specifications Specifications for Level 4-compliant cables Specification Value dc resistance (Maximum resistance of a single copper conductor regardless of whether or not it is solid or stranded and regardless of whether or not it is metal coated.) 18.0 Ω/1,000 ft 20 C dc resistance unbalance (maximum) 5% Mutual capacitance of a pair (maximum) 17 pf/foot Pair-to-ground unbalance (maximum) 1,000 pf/foot/1,000 ft Characteristic impedance 772 khz 102 Ω ± 15% 1.0 MHz 100 Ω ± 15% 4.0 MHz 100 Ω ± 15% 8.0 MHz 100 Ω ± 15% 10.0 MHz 100 Ω ± 15% 16.0 MHz 100 Ω ± 15% 20.0 MHz 100 Ω ± 15% Attenuation (maximum db/1,000 ft at 20 C) 772 khz 4.5 db/1,000 ft at 20 C 1.0 MHz 5.5 db/1,000 ft at 20 C 4.0 MHz 11.0 db/1,000 ft at 20 C 8.0 MHz 15.0 db/1,000 ft at 20 C 10.0 MHz 17.0 db/1,000 ft at 20 C Worst-pair near-end crosstalk (minimum) 772 khz 58 db (Values shown are for information only. The minimum NEXT coupling loss for any pair 1.0 MHz 56 db combination at room temperature is to be greater than the value determined using the formula NEXT (F MHz )>NEXT(0.772)-15 log10 (F MHz /0.72) for all frequencies in the range of 4.0 MHz 47 db 0.772 MHz 20 MHz for a length of 1,000 ft.) 8.0 MHz 42 db 10.0 MHz 41 db 16.0 MHz 38 db 20.0 MHz 36 db dc resistance unbalance (maximum) 5% BAS-SVN01A-EN 11

Trane A business of American Standard Companies www.trane.com For more information, contact your local Trane office or e-mail us at comfort@trane.com Literature Order Number File Number Supersedes Stocking Location BAS-SVN01A-EN SV-ES-BAS-BAS-SVN-01A-EN-0603 New Electronic only Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. Only qualified technicians should perform the installation and servicing of equipment referred to in this publication.