Square D Clipsal Two-Channel DIN-Rail DALI Gateway
|
|
|
- Elijah Peters
- 9 years ago
- Views:
Transcription
1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway SLC5502DAL for Use with C-Bus Wired Networks Instruction Bulletin Retain for future use.
2 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. Caution, used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, can result in property damage or improper operation. NOTE: Provides additional information to clarify or simplify a procedure Schneider Electric. All Rights Reserved.
3 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin PLEASE NOTE Class B FCC Statement Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. This document is not intended as an instruction manual for untrained persons. No responsibility is assumed by Square D for any consequences arising out of the use of this manual. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help Schneider Electric. All Rights Reserved. 3
4 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 INTRODUCTION Before You Begin This bulletin provides instructions for installing the Square D Clipsal Two-Channel DIN-Rail Digital Addressable Lighting Interface (DALI) Gateway. The SLC5502DAL provides an isolated two-way communications path between a C-Bus network and two DALI networks and enables C-Bus network control of DALI ballasts. The gateway detects and reports faulty lamps in fluorescent ballasts as well as failed DALI ballasts. DALI Gateways obtain their power from the C-Bus network, so they do not require an external power source. NOTE: DALI networks do not receive power from the C-Bus network, so they require a separate power supply (not included with the DALI Gateway). DALI Gateways are 4M wide (1M = 0.69 in. [17.5 mm]) and designed for mounting in suitably rated DIN-style enclosures, such as the Square D Clipsal 36M Enclosure. Built-in RJ-45 connectors enable quick connection to the C-Bus network and configuration with the C-Bus Toolkit software. Before installing a Two-Channel DIN-Rail DALI Gateway unit, verify that your order is complete by comparing the contents of the package with the list in the table below. Also verify that the catalog number on the box label matches your order. Table 1: Contents of the Box Part Number Description Quantity SLC5502DAL C-Bus Two-Channel DALI Gateway 1 Included with each unit Rubber RJ-45 terminal plugs 3 Included with each unit C-Bus network cable, 15.7 in. (400 mm) Schneider Electric. All Rights Reserved.
5 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin Features Enables two-way communications between C-Bus and DALI networks Invisible to DALI ballasts User-configured addressing structure Receives its power from the C-Bus network LEDs display the status of the power, communications, and the C-Bus network Remote Override (ON and OFF) options Software-selectable network burden and network clock Two standard built-in C-Bus RJ-45 network connectors Non-volatile memory protects unit against power outages Configured by using the C-Bus Toolkit software 2006 Schneider Electric. All Rights Reserved. 5
6 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 COMPONENTS AND OPERATION This section provides a detailed summary of the Two-Channel DIN-Rail DALI Gateway s capabilities and operation. Power The DALI Gateway unit draws 32 ma from the C-Bus network, which is its sole power source. NOTE: DALI networks require a separate (DALI-specific) power supply, which is not included with the DALI Gateway. Status Indicators The front of the DALI Gateway has two status indicator LEDs that display the status of the Unit and the network (see figure Status Indicators, Two-Channel DALI Gateway ). Figure 1: Status Indicators, Two-Channel DALI Gateway KEY: A. Unit-Comms B. C-Bus The Unit-Comms status indicator LED displays a steady light when the DALI Gateway has power and is operating. This LED flashes when data is being transferred between the C-Bus and DALI systems (C-Bus to DALI as well as DALI to C-Bus). Table 2: Unit-Comms Status Indicator Definitions Indicator Status ON Flashing Meaning Power is ON and the unit is functioning Data exchange in progress Schneider Electric. All Rights Reserved.
7 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin C-Bus The C-Bus status indicator LED displays a steady light when there is sufficient network voltage and a valid C-Bus Clock signal. The LED flashes when the available power on the C-Bus network is lower than the current load. The LED is off when there is no C-Bus network clock, there is no C-Bus power to the unit, or the C-Bus power is not sufficient to support the network. Table 3: C-Bus Status Indicator Definitions Indicator Status ON Flashing OFF Meaning Power is ON and the C-Bus network is functioning Marginal C-Bus network power No C-Bus network clock, insufficient power to support the C-Bus network, no C-Bus network connection (check terminations) Remote Overrides The DIN-Rail Relay has provisions for connecting two remote switches that provide Remote Override ON and OFF functions (for wiring examples, see section Remote Override Connections ). Activation of a Remote Override occurs when the switch mechanism contact closes. When one of the remote override inputs is activated, all the group addresses will be set to either ON or OFF accordingly. If the Remote ON and OFF are activated simultaneously, the Remote OFF has priority (see the table Operating Mode Hierarchy ). If Remote ON is activated, the DALI Gateway issues a global message Direct Arc Power 100% to both DALI networks. If Remote OFF is activated, the gateway issues a global message Indirect Arc Power OFF to both DALI networks. Table 4: Operating Mode Hierarchy Mode Priority Function Remote OFF 1 (Highest) Turns all group addresses OFF Remote ON 2 Turns all group addresses ON C-Bus input unit (keypad, PIR, etc.) 3 Controls the group addresses if there is no override in effect 2006 Schneider Electric. All Rights Reserved. 7
8 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 C-Bus System Support The remote switches can be located up to 3280 ft (1000 m) from the DALI Gateway unit. Multiple switches can be connected in parallel to the same remote input, allowing remote control of the unit from different locations by using any type of cable (for wiring examples, see section Remote Override Connections ). A single switch also can be used to remotely control up to 30 different units within the same C-Bus network. NOTE: C-Bus is a balanced network, so C-Bus positive (+) must be present at any point where C-Bus negative ( ) is taken. Therefore both network conductors [C-Bus positive (+) and C-Bus negative ( )] must be looped through all Remote Override input switches on the network. DALI Gateway units can generate a C-Bus system clock signal and a network burden, so they are capable of supporting a simple C-Bus network. See the "Configuration" section for instructions on enabling the clock and burden. C-Bus System Clock DALI Gateway units incorporate a software-selectable C-Bus System Clock, which synchronizes data communications waveforms on the C-Bus network. Typically the clock is disabled: Only one active clock is required for successful C-Bus network communications, and a maximum of three C-Bus units per network should have the clock circuitry enabled. See "Using a System Clock or Network Burden" in the Configuration section for instructions on enabling the clock. Network Burden DALI Gateway units incorporate a software-selectable network burden that can be enabled in the event the network does not yet have a burden. One hardware or software network burden is required for network termination and biasing, but only one network burden should be installed per network. To determine if one must be installed for a network, consult the C-Bus Toolkit software. See "Using a System Clock or Network Burden" in the Configuration section for instructions on enabling the burden Schneider Electric. All Rights Reserved.
9 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin User-Configured Addressing Structure Power Outage and Restoration Standalone Configuration C-Bus to DALI and DALI to C-Bus communications are configured by using the C-Bus Toolkit software. All C-Bus units have onboard non-volatile memory, which is used to store the operating state of the unit in case of a power outage. The DALI Gateway draws 32 ma from the C-Bus network, making it possible to configure the unit without a connection to an external power source. Requirements for configuring a unit include connection to an operational C-Bus network that is capable of supporting one or more extra C-Bus units (32 ma current required per gateway). For more information about configuration requirements, see "Configuration" in the "Installation" section Schneider Electric. All Rights Reserved. 9
10 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 SAFETY PRECAUTIONS This section contains important safety precautions that must be followed before attempting to install or maintain electrical equipment. Carefully read and follow the safety precautions below. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This equipment must be installed and serviced by qualified electrical personnel. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E. Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury. Transient Voltage Surge Protection Each unit incorporates transient protection circuitry. Additional external power surge protection devices should be used to enhance system immunity to power surges. It is strongly recommended that appropriate transient voltage surge protection be installed at all service entrance equipment Schneider Electric. All Rights Reserved.
11 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin INSTALLATION Network Considerations Configuration Prerequisites Follow the procedures in this section to mount the DALI Gateway units and to make electrical and C-Bus network wiring connections. The DALI Gateway units draw 32 ma from the C-Bus network at all times. Determine the total network current load and verify that there will be adequate C-Bus power to support all the connected devices. Also verify that the amount of available power is no more than 2 A. Generally, one physical C-Bus network can have a maximum of 50 DALI Gateway units. However, the design of the network, including the specific number and types of units on it, could decrease the maximum number of allowable DALI Gateway units. Before a DALI Gateway can operate on the C-Bus network, the C-Bus Toolkit software must be used to assign a unique identification (unit address) and mode of operation on the network. When the units are being installed as part of a large or complex network, it is most efficient to perform the basic configuration before the units are physically installed. However, the units can be configured before or after physical installation. The following components are typically required to configure a DALI Gateway unit. (Specific items and product numbers can vary according to the network and type of C-Bus unit.) PC with the C-Bus Toolkit software installed DALI Gateway unit being configured (SLC5502DAL) Using a C-Bus Clock or Network Burden The following sections describe how to enable and disable a system clock or a network burden. All procedures are carried out by using the C-Bus Toolkit software. NOTE: A C-Bus network should have a maximum of three system clocks and one network burden enabled Schneider Electric. All Rights Reserved. 11
12 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 Enabling a System Clock or Network Burden NOTE: Remove any hardware burden if a software burden is to be enabled. HAZARD OF IMPROPER OR UNSTABLE OPERATION Networks require only one burden. Before enabling a network burden, use the graphical user interface (GUI) software to verify that the network does not already have one. Failure to follow this instruction can result in improper C-Bus network operation. 1. Start the C-Bus Toolkit software 2. If this is a new unit, add it to the network and set its Address. 3. Double-click on the unit's name to open its graphical user interface (GUI). 4. Find the check boxes for Enable C-Bus Clock and Enable Burden. In the DALI Gateway GUI they might be on the top right side of the page. If either box already has been selected, that function has been enabled at this unit. NOTE: There should be a maximum of one network burden and three system clocks per C-Bus network. 5. Verify that the network has fewer than three clocks enabled. To enable a system clock at this unit, select (click in) the box next to Enable C-Bus Clock. 6. Verify that the network does not already have a burden enabled. To enable a burden at this unit, select (click in) the box next to Enable Burden. 7. Click on the OK button. 8. When the Save Location dialog box opens, click on the OK button. The graphical user interface will close Schneider Electric. All Rights Reserved.
13 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin Disabling a System Clock or Network Burden 1. Start the C-Bus Toolkit software. 2. Double-click on the unit's name to open its graphical user interface (GUI). 3. Find the check box for Enable C-Bus Clock or Enable Burden and click in the box until it is empty. 4. Click on the "OK" button. 5. When the "Save Location" dialog box opens, click on the "OK" button. The graphical user interface will close. Identifying the C-Bus Units and Their Locations The location of each C-Bus unit must be tracked. Two recommended methods are given below, one for when the units are configured before installation (see section Labeling the C-Bus Units ), the other for when the units are configured after installation (see section Recording Each Unit s Location ). Labeling the C-Bus Units When C-Bus units are configured before physical installation, it is important to label them to indicate where they are to be placed. One method for doing this would be to write each unit s address directly on it. NOTE: Verify that each configured unit has been marked to indicate where it should be placed in an enclosure or a building or site. Recording Each Unit's Location In order to track C-Bus units that will be configured after physical installation, they must be identified and their location must be recorded at the time they are installed. NOTE: If a unit has already been configured and assigned a location on a site map, it is not necessary to make another record of its location Schneider Electric. All Rights Reserved. 13
14 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 HAZARD OF UNEXPECTED OR IMPROPER SYSTEM BEHAVIOR Properly record the physical location of each unit using the lift-and-peel label provided on the box and a site plan or location log. Retain location records and provide them to the person(s) responsible for configuring and commissioning the network. Failure to follow these instructions can result in unexpected or improper system behavior. Before installing a unit, use the following guidelines to record its location. Recording each unit's location is required for configuration with the C-Bus Toolkit software. Each unit is identified by a unique serial number found on the box label (see the figure Box Label with Lift-and-Peel Section ). The serial number provides important information for recording a unit's location. Figure 2: Box Label with Lift-and-Peel Section KEY: A. Serial number B. Bar code C. Lift-and-peel section The box label also has a bar code that can be read by an infrared scanner and used for a record of a specific unit s location. A liftand-peel section of the box label duplicates the box label s information (see Box Label with Lift-and-Peel Section diagram). To record the location of a unit, remove the lift-and-peel section from the box label and attach it to a site plan or other document. The lift-and-peel section now provides a record of the physical location where that unit is installed. When installing multiple units of one kind in an area or enclosure, such as six four-channel DIN dimmers in an enclosure, verify that the document or site plan indicates the relative position of each specific unit Schneider Electric. All Rights Reserved.
15 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin Mounting DIN-Rail Units onto the DIN Rail The DIN-rail units are designed to be installed onto a standard 1.38 in. (35 mm) DIN rail. To mount (i.e., attach) the dimmer unit, hook it onto the top of the DIN rail. Swing the bottom of the unit down until it clicks into place. Figure 3: Mounting the Unit onto the DIN Rail KEY: A. DIN rail B. DIN-rail unit 1. Hook the unit onto the top of the DIN rail 2. Swing the bottom of the unit down 3. Mounted unit Removing DIN-Rail Units from the DIN Rail Use a small flat-bladed screwdriver to pull either the upper or lower slide release out and disengage the unit from the DIN rail. Figure 4: Removing the Unit from the DIN Rail KEY: A. DIN rail B Unit 1. Pull out the slide release 2. Pull the unit away from the DIN rail 3. Lift the unit away from the rail 2006 Schneider Electric. All Rights Reserved. 15
16 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 Electrical Wiring Connections Follow the safety precautions and guidelines for making electrical connections that are given in this section. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage-sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury. NOTE: DALI networks are typically wired as Class 1 control circuits. Although DALI networks have a low operating voltage of 16 V, dangerous voltage levels could appear on DALI wiring as a result of wiring errors or insulation faults Schneider Electric. All Rights Reserved.
17 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin Wiring Guidelines The guidelines below are important to consider when working with DIN-Rail DALI Gateways. Verify that the power to the system is turned OFF before handling electrical power conductors. Observe national and local electrical codes. Verify the number and types of units that can be connected to this network (see section Network Considerations ). Consult the figure Electrical Wiring Connections to connect a DALI network to the gateway. Use suitably rated copper DALI cable, one #12 or two #14 22 AWG (one x 3.1 mm² or two x 2.0 mm² 0.33 mm²). Isolate the DALI Gateway unit from the electrical power lines. The recommended torque for tightening the terminal screws is 5 lb-in. (0.56 Nm). Do not exceed this torque. Insert the rubber terminal plugs into any unused RJ-45 ports. Do not Megger test C-Bus data cabling or terminals. HAZARD OF C-BUS NETWORK PERFORMANCE DEGRADATION Do not Megger test C-Bus data cabling or terminals as it can degrade the performance of the C-Bus network. Failure to follow this instruction will result in damage to the C-Bus network Schneider Electric. All Rights Reserved. 17
18 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 Connecting a DALI Gateway Unit to a DALI Network Optocouplers in the DALI Gateway isolate the DALI networks from each other and from the C-Bus network. Use any suitably rated copper DALI cable, one #12 or two #14 22 AWG (one x 3.1 mm² or two x 2.0 mm² 0.33 mm²) for the connection between the DALI Gateway and DALI network. Figure 5: Electrical Wiring Connections KEY: NOTE: Use suitably rated copper cable, one #12 or two #14 22 AWG (one at 3.1 mm² or two at 2.0 mm² 0.33 mm²). DALI 1: DALI Network 1 (typical connections) DALI 2: DALI Network 2 A. Power B. DALI power supply C. Fixture with DALI ballasts D. Hot, neutral, and ground connections E. C-Bus RJ-45 connections Connecting the DALI Gateway Unit to the C-Bus Network The DALI Gateway unit is connected to the C-Bus network through one of the RJ-45 sockets (see the figure Connecting to the C-Bus Network ). Use Category 5 unshielded twisted pair (UTP) data cable and an appropriately wired RJ-45 connector to make the connection (see figure C-Bus Wiring Connections and table C-Bus Cable Conductor Assignments ). NOTE: The C-Bus connection is polarity sensitive. Verify that the C-Bus network connection is to the C-Bus connections port [see (A and C) in figure "Connecting to the C-Bus Network"]. NOTE: Insert the provided rubber plugs into any unused RJ-45 cable terminals Schneider Electric. All Rights Reserved.
19 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin Figure 6: Connecting to the C-Bus Network KEY: A. C-Bus wiring connections B. RJ-45 connectors C. RJ-45 pin outs D. Rubber RJ-45 terminal plug for any unused port A Cat 5 UTP patch cord is included with the unit to facilitate easy interconnection of units. Verify that the network current load and available power are within limits (see the section Network Considerations ) before adding any units to the C-Bus network. Prevent wire clippings and other debris from entering the DALI Gateway unit by inserting a rubber RJ-45 terminal plug into any unused ports. Figure 7: C-Bus Wiring Connections KEY: A. C-Bus positive (+): blue + orange B. C-Bus negative (-): blue-white + orange-white C. Remote OFF: brown + brown-white D. Remote ON: green + green-white Table 5: C-Bus Cable Conductor Assignments RJ Pin C-Bus Network Connection Color 1 Remote ON Green-White 2 Remote ON Green 3 C-Bus Neg ( ) Orange-White 4 C-Bus Pos (+) Blue 5 C-Bus Neg ( ) Blue-White 6 C-Bus Pos (+) Orange 7 Remote OFF Brown-White 8 Remote OFF Brown 2006 Schneider Electric. All Rights Reserved. 19
20 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 Remote Override Connections NOTE: External voltage sources are not required and MUST NOT be connected to either of the Remote Override inputs. The C-Bus connectors have extra pairs of conductors (see the figure C-Bus Wiring Connections and the table C-Bus Cable Conductor Assignments ) that can be used to enable Remote Overrides (ON/OFF) that will operate without using the C-Bus network, as is discussed in the section Remote Overrides. The Remote Override connections are optional, but it is recommended that they be maintained for correct operation of these services across the C-Bus network. The Remote Override (ON/OFF) services can be disabled by using the C-Bus Toolkit software. NOTE: C-Bus is a balanced network, so C-Bus positive (+) must be present at any point where C-Bus negative ( ) is taken. Therefore both network conductors [C-Bus positive (+) and C-Bus negative ( )] must be looped through all Remote Override input switches on the network. The figure "Wiring for Remote Overrides" shows how one or more switches can be connected in parallel on any one network. If connecting a Remote ON switch, use the green and green white conductors; if connecting a Remote OFF switch, use the brown and brown white conductors. Remote Overrides are triggered by connecting the relevant conductors to C-Bus negative (see the figure Wiring for Remote Overrides and the table C-Bus Cable Conductor Assignments ). Figure 8: Wiring for Remote Overrides KEY: 1. Remote ON connections 2. Remote OFF connections A. Remote OFF: Brown + Brown-White B. C-Bus negative ( ):Orange-White + Blue-White C. Remote ON: Green + Green-White D. C-Bus positive (+): Orange + Blue Schneider Electric. All Rights Reserved.
21 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin STANDARDS Table 6: U.S. and Canadian Product Safety Standards and U.S. FCC Regulations Standards/Regulations CSA C22.2 No. 205 Title Complies with cul Standards for Signal Equipment UL916 Energy Management Equipment FCC Part 15 Complies with FCC Standards for Home or Office Use Table 7: Other Standards and Directives Regulation AS/NZS 3548 IEC Title Limits and Methods of Measurement of Radio Interference of Information Technology Equipment General Emission 2006 Schneider Electric. All Rights Reserved. 21
22 Square D Clipsal Two-Channel DIN-Rail DALI Gateway A1 Instruction Bulletin 10/2006 SPECIFICATIONS Table 8: Two-Channel DALI Gateway Specifications Nominal Voltage Requirements Max. # Gateway Units per C-Bus Network V 32 ma, drawn from the C-Bus network Based on the total network current load and available power. Status Indicators C-Bus Connections Gateway to DALI Terminals Dimensions Weight 4.6 oz (130 g) Unit-Comms LED: Unit power C-Bus LED: Power levels and presence of C-Bus clock Two RJ-45 connectors, in. (400 mm) patch lead included Use suitably rated DALI copper cable, one #12 or two #14-22 AWG (1 x 3.1 mm² or 2 x 2.0 mm² 0.33 mm²) 2.8 in. (L) x 3.4 in. (W) x 2.6 in. (H) [72 mm (L) x 85 mm (W) x 65 mm (H)] Mounting Operating Environment DIN rail, 4M wide Temperature: 32 F 113 F (0 C 45 C) Relative Humidity: 95%, noncondensing Dimensions Figure 9: Dimensions of the Two-Channel DIN-Rail DALI Gateway Schneider Electric. All Rights Reserved.
23 A1 Square D Clipsal Two-Channel DIN-Rail DALI Gateway 10/2006 Instruction Bulletin SUPPORT AND SERVICE Contact the Square D Customer Information Center for technical support by phone at Square D ( ) or at [email protected]. Contact your local Square D service representative or Square D Clipsal certified installer for repairs or service to your network. You may also find helpful information on our web site at Schneider Electric. All Rights Reserved. 23
24 Square D Clipsal Two-Channel DIN-Rail DALI Gateway Instruction Bulletin Schneider Electric, USA 295 Tech Park Drive La Vergne, TN, SquareD ( ) Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. Square D,, Clipsal, C-Bus, and Powerlink are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries Schneider Electric. All Rights Reserved A1 10/2006
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Square D Clipsal C-Bus Network Analyzer
Square D Clipsal C-Bus Network Analyzer for Use with C-Bus Wired Networks Instruction Bulletin Retain for future use. Square D Clipsal C-Bus Network Analyzer 63249-420-234A1 Instruction Bulletin 12/2006
How To Fix A Cbus Network From A Power Supply To A Power Source
Online Introductory C-Bus Network Tutorial Square D Clipsal C-Bus Products Training Course Basic Series Online Introductory C-Bus Network Tutorial 1250SM0702A1 Square D Clipsal C-Bus Products Training
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
=============================== WARNING
=============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that
FCC COMPLIANCE STATEMENT
MEDIA CONVERTER Fiber to UTP Ethernet Media Converter ET90110SC ET90110ST Instruction Guide * Actual product may vary from photo Revised: December 6, 2002 The Professionals Source For Hard-to-Find Computer
USB/VGA Cat 5 UTP Console Extender
USB/VGA Cat 5 UTP Console Extender SV565UTPU SV565UTPUGB SV565UTPUEU Instruction Manual FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
ADSL Modem Installation Guide. Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000. ADSL Modem Installation Guide
ADSL Modem Installation Guide Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000 ADSL Modem Installation Guide Installation Instructions Westell ADSL Modem 1. Package Inspection and Contents...2
INSTALLATION GUIDE ConnectLine TV Adapter Getting started
INSTALLATION GUIDE ConnectLine TV Adapter Getting started PURPOSE OF THIS GUIDE READ THIS FIRST Before your hearing instruments can receive sound from the TV, the adapter must be connected to the TV and
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
IFS SP-PoE Splitter User Manual
IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware
EPSON USB/Parallel Adapter User s Guide
EPSON USB/Parallel Adapter User s Guide EPSON Stylus COLOR 440 EPSON Stylus COLOR 800 EPSON Stylus COLOR 600 EPSON Stylus COLOR 850 EPSON Stylus COLOR 640 EPSON Stylus COLOR 1520 EPSON Stylus Photo EX
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Pad. Quick Start Guide
Pad Quick Start Guide Copyright 2008 Mimio Congratulations on your mimio Pad purchase! mimio Pad is a 4 GHz wireless pad. To configure mimio Pad for use, install the mimio Studio software and plug the
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
Energy Smart Electric Water Heater Controller
Installation, Operation and Troubleshooting Instructions Energy Smart Electric Water Heater Controller Table of Contents Installation and Setup, 2 Operation, 5 Troubleshooting, 7 Regulatory Notices, 11
HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual
HP-1000E v2 Powerline Ethernet Adapter User s Manual HP1000E v2 User s Manual Table of Contents Chapter 1: Introduction...1 Chapter 2: Planning your Powerline Network...1 Network Topology...1 Chapter 3:
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT
C-Bus Single Zone Thermostat 5070THB Series REGISTERED DESIGN REGISTERED PATENT Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008.
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
110244-003. PrintPAD CN3/4/3e/4e. User Guide
110244-003 PrintPAD CN3/4/3e/4e User Guide TABLE OF CONTENTS PrintPAD CN3/4 & PrintPAD CN3e/4e Printer Views...1 Open View...1 Closed View...1 Using Batteries: General Guidelines...1 Installing and/or
Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
RC8021 Indoor Camera Installation Guide
RC8021 Indoor Camera Installation Guide P/N: 957YL502GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owners i Package
user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4
user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable
Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA
Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
2 Port KVM Switch. If anything is damaged or missing, contact your dealer.
2 Port KVM Switch User Manual CS-82A Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect
Perle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
C-Bus Basic Training Manual Volume 1. 1A. Introduction to C-Bus 1B. C-Bus Concepts 1C. C-Bus Hardware Revision Number: V2
C-Bus Basic Training Manual Volume 1 1A. Introduction to C-Bus 1B. C-Bus Concepts 1C. C-Bus Hardware Revision Number: V2 Copyright Clipsal Australia Pty Ltd 2007. All rights reserved. This material is
USB Mini Print Server PS121. Installation Guide
USB Mini Print Server PS121 Installation Guide Introduction Thank you for purchasing a NETGEAR PS121 USB Mini Print Server. With this print server you can share your printer with all the computers in your
Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location
45136 Wireless Alarm System Alarm Siren User s Manual Low Batt On Armed ON/OFF LEARN Choice ALERT Control all Sensors & accessories from one location Table of Contents Important Safeguards 4 Introduction
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS
TM BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS IN-HOME ASSEMBLY OF YOUR BIGGAMES HOME VIDEO ARCADE MAY BE AVAILABLE IN YOUR AREA FOR AN ADDITIONAL CHARGE. FOR INFORMATION, PLEASE CALL (800) 749-4345.
USB to VGA Adapter USB2VGAE2. Instruction Manual. USB 2.0 to VGA Multi Monitor External Video Adapter
USB to VGA Adapter USB2VGAE2 Instruction Manual USB 2.0 to VGA Multi Monitor External Video Adapter *Please ensure that the driver installation is complete prior to the physical installation of the USB
FTP-1000 Touchpad/Display. Installation Manual. Stay. Away. Disarm. Quick Exit
FTP-1000 Touchpad/Display Installation Manual A B 1 2 3 4 5 6 7 8 9 0 * # Stay Away Disarm Quick Exit C D Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
Wave/PC Interactive System USB Adapter Kit. Installation Guide
Wave/PC Interactive System USB Adapter Kit Installation Guide Safety Information 1. Read these instructions for all components before using this product. 2. Keep these instructions for future reference.
Bluetooth Stereo Headphone. User Guide. Hive
Bluetooth Stereo Headphone User Guide Hive 1. Product Description Avantree Hive is a Bluetooth stereo headphone with MIC from the Avantree family. It delivers clear voice transmission and high quality
Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual
High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions
4-Port Pocket. USB KVM Switch with USB 2.0 Hub
4-Port Pocket USB KVM Switch with USB 2.0 Hub Manual - 1 - Index 1. INTRODUCTION... 3 1.1 FEATURES... 3 1.2 PHYSICAL DIAGRAM... 4 1.3 PACKAGE CONTENTS... 4 2. SPECIFICATIONS... 5 2.1 ERAL... 5 2.2 LED
palm Switch 500 5 Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide
palm Switch 500 5 Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide Rev. 1.0 June, 2003 User Guide 1. Introduction Welcome to the World of Mini-Networking. In the modern business society, communication
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
VGA USB KVM Console Extender over CAT5 UTP (500 ft)
VGA USB KVM Console Extender over CAT5 UTP (500 ft) SV565UTPU SV565UTPUGB SV565UTPUEU DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com
e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL
Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
For the US-market only! CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts
BeoLab 6000 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent fire
The Third Rail System User Manual
The Third Rail System User Manual System Contents: Slim Case and Smart Battery for iphone 4 Slim Case for iphone 4 Smart Battery micro-usb Cable USB Adapter Cable User Manual Smart Battery only Smart Battery
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
CONSOLE REMOTE I /O AC 9V
CONSOLE CONSOLE REMOTE I /O AC 9V AC 9V REMOTE I /O User Manual CE-220 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units
ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide
31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become
Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.
Sense Components Sense monitor Antenna assembly External mounting kit Current sensors Download the Sense app. Go to sense.com/app Power cable Technical Specifications Sense is a home energy monitoring
Universal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
Serial ATA Hard Drive Docking Station
Serial ATA Hard Drive Docking Station UNIDOCK2U Instruction Manual USB to SATA, IDE External Hard Drive Docking Station for 2.5 or 3.5 Hard Drives FCC Compliance Statement This equipment has been tested
2.5/3.5 SATA HDD Docking Station
SATADOCKU2 SATADOCKU2E SATADOCK22UE 2.5/3.5 SATA HDD Docking Station FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
OC810 Outdoor Camera Setup Guide
OC810 Outdoor Camera Setup Guide P/N: 957YU60001 Document Version: 1.0 Copyright 2010. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package Contents
Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server
Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server NETRS232485 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
INSTALLATION GUIDE. AXIS T8133 Midspan 30W
INSTALLATION GUIDE AXIS T8133 Midspan 30W ENGLISH Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis Communications
SATA and SAS Hard Drive Backplane
SATSASBAY3BK Instruction Manual SATA and SAS Hard Drive Backplane 3 Drive 3.5 Removable SATA/SAS Mobile Rack Backplane FCC Compliance Statement This equipment has been tested and found to comply with the
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1
BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved
Instruction Guide. Professional VGA to NTSC/PAL TV Converter with Remote VGA2NTSCPRO. The Professionals Source For Hard-to-Find Computer Parts
VIDEO CONVERTER Professional VGA to NTSC/PAL TV Converter with Remote VGA2NTSCPRO Instruction Guide * Actual product may vary from photo Revised: February 4, 2003 The Professionals Source For Hard-to-Find
Model 70A00-1. GSM Cellular Communications Center
Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
InnoMedia ESBC 9380-4B. Quick Install Guide. www.innomedia.com 1
InnoMedia ESBC 9380-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
USB 2.0 Peripheral Switch USER MANUAL US221A / US421A
USB 2.0 Peripheral Switch USER MANUAL US221A / US421A FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Residential Gateway (RG) Battery Backup REV B
Residential Gateway (RG) Battery Backup REV B Save this user manual This manual contains important instructions regarding the installation and operation of this device. Read this manual thoroughly before
RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack
RC930 Manual 6/10/99 1:23 PM Page 1 Wireless Modem Jack Table of Contents Safety Precautions...1 Important Notes...4 Getting Started...5 System Installation...5 Connecting to Computer...6 Trouble Shooting...7
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
VS-0202 VS-0204. User Manual
User Manual VS-0202 VS-0204 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them.
Power supply unit Model: PAC-SC50KUA
Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
Broadband Telecommunications Drop Amplifier
INSTALL SHEET BDA Broadband Telecommunications Drop Amplifier Introduction The Broadband Telecommunications Drop Amplifier (BDA) is a two-way, 1 GHz amplifier designed for customer-premise amplification
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
HDMI Switch USER MANUAL VS481A
HDMI Switch USER MANUAL VS481A FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
OC810 Outdoor Camera Installation Guide
OC810 Outdoor Camera Installation Guide P/N: 957YU601GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
QNAP RAID Expansion Enclosure Hardware User Manual. 2014. QNAP Systems, Inc. All Rights Reserved.
QNAP RAID Expansion Enclosure Hardware User Manual 2014. QNAP Systems, Inc. All Rights Reserved. Thank you for choosing QNAP products! This user manual provides descriptions of the hardware of the QNAP
Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10
Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation
Manual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
READ FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
HDMI over Cat5 Video Extender with RS232 and IR Control
HDMI over Cat5 Video Extender with RS232 and IR Control ST121UTPHD2 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
Kinivo 301BN HDMI Switch
Kinivo 301BN HDMI Switch User Manual 2012 Kinivo LLC. All rights reserved. Kinivo is a trademark of Kinivo LLC. Bluetooth word mark and the Bluetooth logo are registered trademarks of Bluetooth SIG. All
Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating