NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals



Similar documents
AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Technical catalogue. Modular DIN rail components Installation contactors

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Electronic overload relay EF65, EF96 and EF146

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Catalog. Modular DIN rail components Installation contactors

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ZS25 Screw Clamp Terminal Blocks Feed-through

Electronic overload relay EF19 and EF45

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: DILM9 10(24VDC) Article No.:

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Analog signal converters CC-E I/I Current / current isolators

Manual motor starter MS116

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

R.C.C.B. s two-pole LEXIC

ZS10 Screw Clamp Terminal Block

Technicaldata General

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM4TG20 three-phase network control relay RM4-T - range V

D-Line Contactors, Overload Relays and Accessories

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Relés e Contatores de Estado Sólido SIRIUS

Bimetallic Overload Relay Specifications

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Panorama. Motor protection and control Manual motor starters, contactors and overload relays

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Manual Motor Starter MS 116 up to 16 A Technical Data

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Thermistor motor protection

48 SERIES Relay interface modules 10 A

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

RY2 miniature industrial relays

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Pluggable interface relays CR-P Pcb relays

PSR The compact range Description

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

38 Series - Relay interface modules A

Safety automation solutions

49 Series - Relay interface modules A. Features

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

38 Series - Relay interface modules A

System pro M compact Miniature Circuit Breaker S 200/S 200 M

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

E-STOP relays, safety gate monitors

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

MasterINTERFACE 39 Series - Relay interface modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Preventa Machine Safety Products

MasterINTERFACE 39 Series - Relay interface modules

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Redundancy Module QUINT-DIODE/40

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

SURGE PROTECTIVE DEVICES

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

CompactLogix Power Supplies Specifications

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Safety dialogue solutions

EBS852 (Contrac) Power Electronic Unit

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Safety technique. Emergency stop module BO 5988 safemaster

Bulletin 150 SMC Flex Smart Motor Controller Specifications

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Catalog January. Heavy industrial power applications Motor contactors and starters

High Performance Circuit Breaker S800HV-K for applications up to 1000 V AC

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Pendant control stations 6

Safety detection solutions

Transcription:

Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z) contactor relays include an electronic coil interface providing reduced pull-in and holding consumption, particularly for AC control circuits Only four coils are needed to cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC NF(Z) offer extended operating limits and are suitable worldwide for different control voltages. e.g.: the coil 100...250 V 50/60 Hz - DC is suitable for Europe (230 V 50 Hz) and for North America (120 V 60 Hz and 208 V 60 Hz). NF(Z) contactors can manage large control voltage variations. NFZ contactor relays equipped with a 24...60 V 50/60 Hz - 20...60 V DC coil allow direct control by 24 V DC 500 ma PLC-output NFZ contactor relays withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) NF(Z) contactor relays have built-in surge protection and do not require additional surge suppressors The contactor relays have mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and include the "Mechanically Linked" symbol on their side. 3D CAD outline drawings available on «Control Product 3D» portal Ordering Details Number of contacts Control voltage Type Order code EAN Weight 1st stack 2nd stack Uc min.... Uc max. Pack (ing) 1 piece V 50/60 Hz V DC kg Contactor Relays 13 14 23 24 33 34 43 44 53 54 61 62 73 74 83 84 24...60 20...60 NF71E-11 1SBH 137 001 R1171 3471523100411 0.320 48...130 48...130 NF71E-12 1SBH 137 001 R1271 3471523100428 0.320 100...250 100...250 NF71E-13 1SBH 137 001 R1371 3471523100435 0.320 250...500 250...500 NF71E-14 1SBH 137 001 R1471 3471523100442 0.360 Note: NF71E-11 not suitable for a direct control by PLC-output. NF71E-11 available in some countries: please consult your ABB representative. Contactor Relays - Low Consumption 13 14 23 24 33 34 43 44 53 54 61 62 73 74 83 84-12...20 NFZ71E-20 1SBH 136 001 R2071 3471523102002 0.360 24...60 20...60 NFZ71E-21 1SBH 136 001 R2171 3471523102019 0.360 48...130 48...130 NFZ71E-22 1SBH 136 001 R2271 3471523102026 0.360 100...250 100...250 NFZ71E-23 1SBH 136 001 R2371 3471523102033 0.360 Note: Only NFZ contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: + for the positive pole and - for the negative pole Certifications and Approvals CE culus CCC GOST C-Tick ABB Technical Datasheet 1SBC101433D0201 1

Contact Utilization Characteristics according to IEC Standards IEC 60947-1 / 60947-5-1 and EN 60947-1 / 60947-5-1 Rated operational voltage Ue max. 690 V Conventional free-air thermal current Ith θ 40 C 16 A Rated frequency limits 25... 400 Hz Rated operational current Ie / AC-15 acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6 A 220-240 V 50/60 Hz 4 A 400-440 V 50/60 Hz 3 A 500 V 50/60 Hz 2 A 690 V 50/60 Hz 2 A Making capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1 Breaking capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1 Rated operational current Ie / DC-13 acc. to IEC 60947-5-1 24 V DC 6 A / 144 W 48 V DC 2.8 A / 134 W 72 V DC 1 A / 72 W 110 V DC 0.55 A / 60 W 125 V DC 0.55 A / 69 W 220 V DC 0.27 A / 60 W 250 V DC 0.27 A / 68 W 400 V DC 0.15 A / 60 W 500 V DC 0.13 A / 65 W 600 V DC 0.1 A / 60 W Short-circuit protection gg type fuse 10 A Rated short-time withstand current I cw for 1.0 s 100 A for 0.1 s 140 A Minimum switching capacity 12 V / 3 ma with failure rate acc. to IEC 60947-5-4 10-7 Non-overlapping time between N.O. and N.C. contacts 2 ms Heat dissipation per pole at 6 A 0.1 W Max. electrical switching frequency AC-15 1200 cycles/h DC-13 900 cycles/h Main Pole - Utilization Characteristics according to UL / CSA Standards UL 508, CSA C22.2 N 14 Rated insulation voltage U i 600 V Max. rated voltage 600 V AC, 600 V DC Pilot duty A600, Q600 AC thermal rated current 10 A AC maximum volt-ampere making 7200 VA AC maximum volt-ampere breaking 720 VA DC thermal rated current 2.5 A DC maximum volt-ampere making-breaking 69 VA 2 Technical Datasheet 1SBC101433D0201 ABB

General Technical Data Rated insulation voltage Ui acc. to IEC 60947-5-1 acc. to UL / CSA Rated impulse withstand voltage Uimp Electromagnetic compatibility Ambient air temperature close to contactor Operation in free air -40... +70 C Storage -60... +80 C Climatic withstand Operating altitude Mechanical durability Number of operating cycles Max. switching frequency Shock withstand acc. IEC 60068-2-27 and EN 60068-2-27 Mounting position 1 C1 Closed or open position A A B1 Vibration withstand acc. to IEC 60068-2-6 C2 B2 Shock direction A B1 B2 C1 C2 690 V 600 V 6 kv Devices complying with IEC 60947-1 / EN 60947-1 - Environment A Category B according to IEC 60947-1 Annex Q 3000 m 20 millions operating cycles 6000 cycles/h 1/2 sinusoidal shock for 11 ms: no change in contact position 30 g 25 g Closed position / 5 g Open position 15 g 25 g 25 g 5... 300 Hz 4 g Closed position / 2 g Open position Magnet System Characteristics Coil operating limits AC supply at θ 60 C 0.85 x Uc min... 1.1 x Uc max acc. to IEC 60947-5-1 at θ 70 C 0.85 x Uc min... Uc max DC supply at θ 60 C 0.85 x Uc min... 1.1 x Uc max at θ 70 C (NF) 0.85 x Uc min... Uc max - (NFZ) 0.85 x Uc min... 1.1 x Uc max AC control voltage Rated control circuit voltage Uc 24... 500 V AC 50/60 Hz Coil consumption Average pull-in value (NF) 50 VA - (NFZ) 16 VA Average holding value (NF) 2.2 VA / 2 W - (NFZ) 1.7 VA / 1.5 W DC control voltage Rated control circuit voltage Uc 12... 500 V DC Coil consumption Average pull-in value (NF) 50 W - (NFZ) 12... 16 W Average holding value (NF) 2 W - (NFZ) 1.7 W PLC-Output control (NFZ) 500 ma 24 V DC Drop-out voltage in % of Uc min. 60 % Uc min Voltage sag immunity according to SEMI F47-0706 (NFZ) conditions of use on request Dips withstand (level 0% according to IEC 61000-4-11) (NFZ) 22 ms average for Uc = 24... 250 V 50/60Hz -20 C θ +60 C Operating time between coil energization and: N.O. contact closing 40... 95 ms N.C. contact opening 38... 90 ms between coil de-energization and: N.O. contact opening 11... 95 ms N.C. contact closing 13... 98 ms Mounting Characteristics Mounting positions Pos. 2 +30-30 Pos. 4 Pos. 3 Pos. 1 Pos. 1 ± 30 Pos. 5 Mounting distances Fixing on rail according to IEC 60715, EN 60715 by screws (not supplied) Max. add-on N.C. auxiliary contacts: see accessory fitting details for a NF contactor relay The contactor relays can be assembled side by side. 35 x 7.5 mm or 35 x 15 mm 2 x M4 screws placed diagonally ABB Technical Datasheet 1SBC101433D0201 3

Connecting Characteristics Main terminals Screw terminals with cable clamp Connecting capacity (min.... max.) Pole and coil terminals Rigid 1 x 1... 2.5 mm² 2 x 1... 2.5 mm² Flexible with non insulated ferrule 1 x 0.75... 2.5 mm² 2 x 0.75... 2.5 mm² Flexible with insulated ferrule 1 x 0.75... 2.5 mm² 2 x 0.75... 1.5 mm² L Bars or lugs L < 8 mm 6 Capacity according to UL/CSA 1 or 2 x AWG 18... 14 Stripping length 10 mm Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 All terminals IP20 Screw terminals (delivered in open position, screws of unused terminals must be tightened) All terminals M3.5 Screwdriver type Flat Ø 5.5 / Pozidriv 2 Tightening torque Pole terminals 1.2 Nm / 11 lb.in Coil terminals 1.2 Nm / 11 lb.in 4 Technical Datasheet 1SBC101433D0201 ABB

Accessory Fitting Details for a NF Contactor Relay Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted. Front-mounted accessories Auxiliary contact blocks Side-mounted accessories Auxiliary contact blocks 1-pole CA4 Left side Right side 1-pole CC4 4-pole CA4 2-pole CAL4-11 1 Overview of main accessories (other accessories available) NF contactor relay 2-pole CAL4-11 4-pole CA4 1-pole CA4, CC4 ABB Technical Datasheet 1SBC101433D0201 5

Main Accessories Ordering Details Description Auxiliary contacts Type Order code EAN Pack (ing) Weight piece Additional auxiliary contact blocks Side-mounted instantaneous auxiliary contact blocks kg (1 pce) 1 1 - - CAL4-11 1SBN 010 120 R1011 3471523130043 1 0.040 1 1 - - CAL4-11-T 1SBN 010 120 T1011 3471523130418 10 0.040 Additional coil terminal block Additional coil terminal block LDC4 1SBN 070 156 T1000 3471523130678 10 0.010 Protective covers Protective covers BX4-CA 1SBN 110 109 W1000 3471523130715 50 0.001 Function markers Function markers BA4 1SNA 235 156 R2700 3472592351568 16 0.011 HTP500-BA4 1SNA 235 712 R2400 3472592357126 1 0.220 SPRC 1 1SNA 360 010 R1500 3472593600108 1 0.290 6 Technical Datasheet 1SBC101433D0201 ABB

Terminal Marking and Positioning Standard devices without addition of auxiliary contacts 13 23 33 43 13 23 33 43 53 61 73 83 53 61 73 83 14 24 34 44 54 62 74 84 NF71E-.. / NFZ71E-.. 54 62 74 84 14 24 34 44 NF71E-.. / NFZ71E-.. Dimensions mm, inches 110.5 4.35" 77 3.03" 45 1.77" 45 1.77" 71 2.80" 5.5 0.22" 10 0.39" 71 2.80" 5.5 0.22" 35 1.38" ø 4.2 0.17" 2 x M4 8-32 U 35 1.38" ø 4.2 0.17" 2 x M4 8-32 U 80 3.15" 6 0.24" 35 mm 80 EN/IEC 3.15" 60715 6 0.24" 5.5 0.22" 35 mm EN/IEC 60715 5.5 0.22" 43 1.69" 60 2.36" 70 2.76" 5 0.20" 60 2.36" 70 2.76" 5 0.20" 10 0.39" 5 0.20" 5 0.20" NF71E NF71E Note: contactor lateral distance to grounded component 2 mm 0.08" min. ABB Technical Datasheet 1SBC101433D0201 7

Contact us ABB France Low Voltage Products Division 10, rue Ampère Z.I. - B.P. 114 F-69685 Chassieu cedex / France You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage products Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2011 ABB All rights reserved Technical Datasheet 1SBC101433D0201 (28/03/11) www.abb.com/lowvoltage