Symmetrical Fault Calculations



Similar documents
THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.

Electrical Fault Level Calculations Using the MVA Method

EEL303: Power Engineering I - Tutorial 4

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

Direct Current Motors

GENERATOR DIFFERENTIAL PROTECTION RELAY STABILITY VIS-A -VIS SELECTION OF CTS MR. H. C. MEHTA & MR. JAY MEHTA Power Linker Group Co.

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

CHECK LIST OF SITE INSPECTION ON LV ELECTRICAL INSTALLATION (Basic Information to be filled by Consultant)

Power Technology Issue 106. Modeling of Three-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

Fault location on power cables. Fault location on power cables

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

Technical Guide. SKM Arc Flash Line Side vs. Load Side

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

Hardware design for ray tracing

Power Technology Issue 104. Modeling of Two-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

EARTHING SYSTEM CALCULATION

Preliminary Feasibility Assessment For. The Rio Tinto Alcan to BCH Transfer Limit of 460 MW. With 50% Series Compensation on Both KMO KIT lines

Fuse Selection Method Module 2. Date of the presentation

Chapter 9 Balanced Faults

STANDARDS. Site-Specific Loss Adjustments PUBLIC

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

SYNCHRONOUS MACHINES

Softstart. Upgrade to Torque control PSTB Contents. 1. ESD Warning Tools PCB information Step by step...

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

TRANSFORMER: THREE PHASE

An Introduction to Fault Tree Analysis (FTA)

The following table shows approximate percentage wise the

Softstart. Changing of Printed Circuit Board, Display, Keypad and upgrade to Torque control PSTB Contents. 1. ESD Warning Tools...

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

SPECIAL TOPICS ON GROUND FAULT PROTECTION AND PROTECTION COORDINATION IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Electricity distribution network design

Earthing Guidance Notes

Lines and Planes in R 3

Dynamic Security Assessment in the Future Grid. Vijay Vittal Ira A. Fulton Chair Professor Arizona State University

Fault Characteristics in Electrical Equipment

NCN8025 / NCN8025A. Compact SMART CARD Interface IC

3-Phase AC Calculations Revisited

Extending Rigid-Flex Printed Circuits to RF Frequencies

ETAP Validation Cases and Comparison Results

Size template. Grid Connection Masterclass Energex John Lansley Senior Network Solutions Engineer

AC vs. DC Distribution: A Loss Comparison

GE Multilin technical note

New 1200V Integrated Circuit Changes The Way 3-Phase Motor Drive Inverters Are Designed David Tam International Rectifier, El Segundo, California

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

ACTIVE NETWORKS: DEMAND SIDE MANAGEMENT & VOLTAGE CONTROL. Master of Science in Energy Systems and the Environment. Jayanth Krishnappa

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Simulation of Ungrounded Shipboard Power Systems in PSpice

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Transient Recovery Voltages (TRVs) for High-Voltage Circuit Breakers Part 2

Universitat Politècnica de València HERE. TODAY. TOMORROW.

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Three-phase analysis of unbalanced systems

Fault Analysis I PowerWorld Corporation

Steady-State Power System Security Analysis with PowerWorld Simulator

PREPARATORY COURSE FOR PE FUNDAMENTALS OF ENGINEERING EXAMINATION (ELECTRICAL ENGINEERING)

Introduction to PowerWorld Simulator: Interface and Common Tools

Installation Considerations for Multi - Motor AC Drives & Filters Used In Metal Industry Applications

Design of Electrical Power Supply System in an Oil and Gas refinery. Master of Science Thesis in Electric Power Engineering

Engineering Recommendation G81 - Part 1: Design and Planning

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

CT Application Guide for the 489 Generator Management Relay

3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS

BJT AC Analysis. by Kenneth A. Kuhn Oct. 20, 2001, rev Aug. 31, 2008

Customer connection enquiry form (For the connection of loads and generators)

PSS SINCAL - Overview -

Data sheet AS-40 / ASP-40. Arc- Series. Architectural Sound Design.

Protection from Short-circuit

Engineering Recommendation G81 Issue: October 2004

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

6. Synchronous machine dynamics

TRANSFORMER LOSS COMPENSATION FOR METERMEN PRESENTED BY: MICHAEL K. BEARDEN

What Matters for Successful Integration of Distributed Generation

SURVEY OF HARMONIC DISTORTION IN LV AND MV NETWORKS: RESULTS AND CORRECTIVE STRATEGIES

Application Note AN- 1095

Agilent Balanced Measurement Example: Differential Amplifiers

1 = 13.8 kv. 1 = 69 kv

TECHNIQUES OF. C.T. Pan 1. C.T. Pan

PowerWorld Transmission Line Parameter Calculator

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

Physical Address: City: State: Zip Code:

Cahier technique no. 158

The Basics of Digital Multimeters

Calculating voltage dips in power systems using probability distributions of dip durations and implementation of the Moving Fault Node method

PowerWorld Transmission Line Parameter Calculator Version 2

APPLICATION NOTE. Increasing PV Hosting Capacity on LV Secondary Circuits with the Gridco System empower TM Solution

Overcurrent Protection for the IEEE 34 Node Radial Test Feeder

Date Day Plan Objective and Essential Question

Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison

COLD JET USED INVENTORY LIST Discounted Price

IF Transformer. V2 is 2Vp-p sinusoidal

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Make your electric distribution network safe

Transcription:

Symmetrical ault Calculations

Eample 1 SCC 1200 10/12.5 Calculate the fault current at

Eample 1 SCC 1200 10/12.5 Step 1: Calculate Base Values I 100 34.5 34.5 100 2 2 2898.55A 11.9ohms 100 Calculate the fault current at

Eample 1 SCC 1200 Step 2: Calculate p.u impedances Tpu t 100 0.06 12.5 old 0.48 10/12.5 Calculate the fault current at

Eample 1 SCC 1200 Step 2: Calculate p.u impedances Tpu t 100 0.06 12.5 old 0.48 10/12.5 Calculate the fault current at utility old 100 34.5 1200 34.5 0.0833 old

Eample 1 SCC 1200 Step 3: Calculate fault current I pu V pu total 1.0 0.48 + 0.0833 1.775 pu 10/12.5 Calculate the fault current at

Eample 1 SCC 1200 Step 3: Calculate fault current I pu V pu total 1.0 0.48 + 0.0833 1.775 pu 10/12.5 Calculate the fault current at I I HV LV I Ipu 3 2898.55 1.775 3 IHV 34.5 13.8 7426 A 2970 A

Eample 2 Addition of a Generator SCC 1200 10/12.5 5 0.12 Calculate the fault current at

Eample 2 Addition of a Generator Step 1: Calculate impedances SCC 1200 10/12.5 5 0.12 utility old 100 34.5 1200 34.5 0.0833 old Calculate the fault current at

Eample 2 Addition of a Generator Step 1: Calculate impedances SCC 1200 10/12.5 5 0.12 utility Tpu 100 34.5 1200 34.5 0.0833 t old 100 0.06 12.5 old 0.48 old Calculate the fault current at

Eample 2 Addition of a Generator Step 1: Calculate impedances SCC 1200 10/12.5 5 0.12 Calculate the fault current at utility Tpu Gpu 100 34.5 1200 34.5 0.0833 t old 100 0.06 12.5 G old 100 0.12 5 0.48 old 2.4 old

Eample 2 Addition of a Generator Step 2: Calculate equivalent impedances SCC 1200 1.0V 10/12.5 5 0.12 utility 0.0833 2.4 Gpu Tpu 0.48 Calculate the fault current at

utility 2.4 Eample 2 Addition of a Generator Step 2: Calculate equivalent impedances 1.0V 0.5633 * 2.4 Eq 0.5633 + 2.4 0.456 0.0833 Tpu 0.48 Gpu 0.456

Eample 2 Addition of a Generator Step 3: Calculate fault current 1.0V 0.5633 * 2.4 Eq 0.5633 + 2.4 0.456 0.0833 utility 2.4 I V 1.0 pu pu Eq 0.456 2.192 pu Tpu 0.48 Gpu 0.456

Eample 2 Addition of a Generator Step 3: Calculate fault current 1.0V 0.5633 * 2.4 Eq 0.5633 + 2.4 0.456 0.0833 utility 2.4 I V 1.0 pu pu Eq 0.456 2.192 pu Tpu 0.48 Gpu 0.456 I I HV LV I Ipu 3 2898.55 2.192 3 IHV 34.5 13.8 9170 A 3668 A

Eample 1 & 2 Comparison SCC 1200 SCC 1200 10/12.5 10/12.5 5 0.12 I 7426 Amps I 9170 Amps

Eample 3 Presence of transformer & motor SCC 1200 10/12.5 5 0.12 3 5% 2.4 M 2500 HP 0.17 Calculate the fault current at

Eample 3 Presence of transformer & motor Step 1: Calculate impedances SCC 1200 10/12.5 5 0.12 utility old 100 34.5 1200 34.5 0.0833 old 3 5% 2.4 M 2500 HP 0.17 Calculate the fault current at

Eample 3 Presence of transformer & motor Step 1: Calculate impedances SCC 1200 10/12.5 5 0.12 utility old 100 34.5 1200 34.5 0.0833 old 3 5% Tpu1 t 100 0.06 12.5 old 0.48 2.4 M 2500 HP 0.17 Calculate the fault current at

Eample 3 Presence of transformer & motor Step 1: Calculate impedances SCC 1200 10/12.5 5 0.12 utility old 100 34.5 1200 34.5 0.0833 old 3 5% Tpu1 t 100 0.06 12.5 old 0.48 M 2500 HP 0.17 2.4 Calculate the fault current at Gpu G 100 0.12 5 old 2.4

Eample 3 Presence of transformer & motor Step 1: Calculate impedances SCC 1200 utility Tpu1 Gpu 0.0833 pu 0.48 pu 2.4 pu 10/12.5 3 5% 5 0.12 Tpu2 t 100 0.05 3 old 1.667 2.4 M 2500 HP 0.17 Calculate the fault current at

Eample 3 Presence of transformer & motor Step 1: Calculate impedances SCC 1200 10/12.5 5 0.12 utility Tpu1 Gpu Tpu2 0.0833 pu 0.48 pu 2.4 pu 1.667 pu M 2500 HP 0.17 3 5% 2.4 Motor Mpu rating 2500 * 0.746 pf 1865 2154 0.866 m old 100 0.17 2.154 7.89 Calculate the fault current at

Eample 3 Presence of transformer & motor Step 1: Calculate impedances SCC 1200 10/12.5 3 5% 5 0.12 2.4 utility Tpu1 Gpu Tpu2 Mpu 0.0833 pu 0.48 pu 2.4 pu 1.667 pu 7.89 pu M 2500 HP 0.17 Calculate the fault current at

Eample 3 Presence of transformer & motor Step 2: Calculate Equivalent impedances SCC 1200 1.0V 10/12.5 5 0.12 0.0833 1.667 utility 2.4 Mpu 3 5% Tpu1 0.48 Gpu 7.89 Tpu2 2.4 M 2500 HP 0.17 Calculate the fault current at

Eample 3 Presence of transformer & motor Step 2: Calculate Equivalent impedances 1.0V 1.0V 0.0833 1.667 utility 2.4 Mpu 0.4354 Gpu Tpu1 0.48 7.89 Tpu2

Eample 3 Presence of transformer & motor Step 3: Calculate fault current 1.0V I V 1.0 pu pu Eq 0.4354 2.297 pu 0.4354 I I HV LV I Ipu 3 2898.55 2.297 3 IHV 34.5 13.8 9609 A 3844 A

Symmetrical ault SCC 1200 SCC 1200 SCC 1200 10/12.5 5 0.12 10/12.5 10/12.5 5 0.12 3 5% 2.4 M 2500 HP 0.17 I 7426 Amps I 9170 Amps I 9609 Amps