5-1 Area Product Description Area Page Series Classification No. Incandescent AEV Incandescent Zone 1 5-2 AEVA-EOLA Obstruction Marker Zone 1 5-6 T100A Small Bulkhead Luminaire Zone 1 5-7 Fluorescent ellk92 Ceiling Mount Fixtures Zone 1 5-8 ellm92 Pole Mount Fixtures Zone 1 5-11 ell 92 Emergency Fixtures Zone 1 5-13 AEVF Exd Fluorescent Luminaires Zone 1 and Zone 21&22 5-15 NDFA Exn/DIP Heavy Duty Fluorescent Zone 2 and Zone 21&22 5-16 nllk Exn/DIP Fluorescent Fixtures Zone 2 and Zone 21&22 5-18 H.I.D. AEVBH Large Bulkhead Luminaire Zone 1 and Zone 21&22 5-20 EVM Hazard Gard HID Fixtures Zone 1 Integral Ballast Factory Sealed and Zone 21&22 5-21 EVME Exde Hazard Gard HID Fixtures Zone 1 Integral Ballast and Zone 21&22 5-26 NVMV Champ HID Exn / DIP Zone 2 Fixtures and Zone 21&22 5-34 Floodlights NFMV Exn Floodlight Luminaire Zone 2 and Zone 21&22 5-39 Beacons FSFB301 Flashing Beacon Zone 1 and Zone 21&22 5-42 FRFB301 Rotating Beacon Zone 1 and Zone 21&22 5-43
5-2 AEV Incandescent Fixtures Flameproof, Exd, IIC, IP66 Zone 1 Application: AEV incandescent lighting fixtures are used: In locations which are hazardous due to the presence of flammable vapours or gases and where dampness or corrosion are present In petroleum refineries, chemical and petrochemical plants and other process industry facilities where similar hazards exist As pendant, ceiling, wall bracket or bulkhead fixtures indoors for general area or room lighting, or outdoors for "spot" lighting Features: Factory sealed - no external seal needed Easy to assemble and relamp Shock absorbing receptacle Gasket seals out dirt and liquids Positive locking of globe holder Inner reflector eliminates upward spill light Light weight, corrosion resistant, copper-free aluminium Standard Materials: Body and guard... Copper free aluminium Glass... configurated glass, heat and impact resistant Standard Finish: Body and guard...grey polyurethane Size Ranges: 20mm through 40mm hubs Capacity Ranges: 100W to 300W incandescent 160W self ballasted mercury vapour 25W SL fluorescent lamp Options: Reflectors Exit Sign AEVX... See Accessories on page 5-4 Compliances: AS2380 Electrical equipment for explosive atmospheres - Flameproof enclosure AS1939 - Degrees of Protection IP66 Certificate of Compliance No. Ex 491 Temperature Classification to AS2480 Incandescent Self-Ballasted Mercury SL Fluorescent Lamp Size T Rating Lamp Size T Rating Lamp Size T Rating 100W T5 160W T4 18W T6 150W T5 25W T6 200W T5 300W T4
5-3 Ordering Information: Max. Lamp Hub Wall Size Style Size Pendant Ceiling Bracket Bulkhead With- 20mm AEVA211 AEVCX211 AEVBX211 AEVJ211 150W Incandescent Guard 25mm AEVA221 AEVCX221 AEVBX221 AEVJ221 SL 18W Fluorescent Without- 20mm AEVA210 AEVCX210 AEVBX210 AEVJX210 Guard 25mm AEVA220 AEVCX220 AEVBX220 AEVJX220 With - 20mm AEVA311 AEVCX311 AEVBX311 AEVJ311 300W Incandescent Guard 25mm AEVA321 AEVCX321 AEVBX321 AEVJ321 SL25W Fluorescent Without- 20mm AEVA310 AEVCX310 AEVBX310 AEVJ310 160W S/B M/V Guard 25mm AEVA320 AEVCX320 AEVBX320 AEVJ320 Notes: 1: Ratings are for lamp base up mounting 2: AEVBX and AEVJ fixtures take 30 angle reflectors only Dimensions: 20mm 25mm Max. Lamp Size Type A B C D E F F 150W AEVA 184 322 298 Incandescent AEVCX 184 347 324 16 20 SL18 Fluorescent AEVBX 184 390 368 318 16 20 AEVJ 184 359 337 244 238 300W AEVA 216 375 343 Incandescent AEVCX 216 397 368 16 20 SL25 Fluorescent AEVBX 216 441 413 333 16 20 160W S/B M/V AEVJ 216 413 384 267 260 Notes: 1: Ratings are for lamp base up mounting 2: When angle reflectors are used, dimension "b" should be changed as follows: add 70mm to AEVA, AEVBX and AEVCX fixtures. Add 76mm to AEVJ fixtures. 3. Remove reflector for application with SL25W lamp
5-4 Replacement Parts & Accessories Lamp Receptacles Glass and holder assemblies Dome 30 Angle Guards High Bay Reflectors Material: Dome and 30 angle... white fibreglass reinforced polyester (Krydon ) High bay... etched Alzak aluminium with natural finish Max. Lamp Size Style Diam. Cat. No. 150W incandescent Dome 300mm RD63 18W fluorescent } 30 Angle 300mm RA63 300W incandescent Dome 400mm RD72 25W fluorescent } 30 Angle 400mm RA72 250W S/B M/V High Bay 370mm EV2912 Receptacles, Guards, Glass & Holder Assemblies Glass & Lamp Holder Fixture Receptacle Guards Assemblies Size Cat. No. Cat. No. Cat. No. 100W-150W EV60 EV505 EV78 200W-300W EV60 EV502 EV7202 Exit Sign Cover Cat. No. AEVXA3584 Photometric Data Lamp : 200W Fixture with glass, 30 angle reflector without guard Total Lumens Eff% With Guard 2090 55.0 Without Guard 2481 65.3 Measurements taken from A-A' plane
5-5 Photometric Data Fixture with glass and with or without guard Fixture with glass, dome reflector and with or without guard Lamp Data: 100W through 300W Note: All data provided is for 200W incandescent lamp. Use following candlepower / lumens multipliers for other lamp sizes: 100W 0.44; 150W 0.72; 300W 1.57 Example: Zonal lumens for 200W lamp without guard for 20-30 is 218. Zonal lumens for 150W lamp for 20-30 is 218 x 0.72 =157 Example: Zonal lumens for 200W lamp without guard for 20-30 is 366. Zonal lumens for 150W lamp for 20-30 is 366 x 0.72 =263 Coefficient of Utilisation Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff.Ceil. Wall 1 2 3 4 5 50.706.601.521.457.403 80 30.659.537.451.382.330 10.618.483.395.326.275 50.671.572.497.435.384 70 30.629.513.432.367.316 10.590.465.380.314.265 50.605.515.449.393.349 50 30.571.468.395.336.291 10.541.426.351.292.247 Coefficient of Utilisation Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff.Ceil. Wall 1 2 3 4 5 50.700.618.547.485.432 80 30.672.576.497.428.373 10.648.540.457.385.330 50.685.606.538.476.423 70 30.659.566.490.424.369 10.636.535.453.382.328 50.655.583.519.459.410 50 30.635.550.478.414.362 10.617.520.445.378.325 50.545.464.404.355.316 30 30.519.426.361.308.266 10.494.392.324.269.229 50.491.416.363.319.284 10 30.469.385.327.280.244 10.449.358.296.247.210 % Reflectance Room Cavity Ratio Eff.Ceil. Wall 6 7 8 9 10 50.362.324.291.265.234 80 30.290.254.224.200.170 10.238.207.177.155.129 50.345.310.279.254.223 70 30.278.244.216.192.165 10.228.199.171.151..126 50.313.282.254.232.205 50 30.256.224.200.178.153 10.214.185.160.141.117 50.284.255.232.212.187 30 30.236.208.183.164.140 10.198.171.149.131.107 50.257.233.210.192.170 10 30.215.191.168.151.128 10.183.158.138.121.099 50.629.561.501.444.397 30 30.613.534.466.405.254 10.597.509.437.373.321 50.607.541.484.430.385 10 30.593.518.455.395.348 10.580.498.430.367.317 % Reflectance Room Cavity Ratio Eff.Ceil. Wall 6 7 8 9 10 50.389.350.316.289.252 80 30.331.294.261.234.197 10.290.255.221.196.162 50.383.345.312.285.248 70 30.328.328.259.232.197 10.287.252.220.196.162 50.370.335.302.277.242 50 30.322.284.254.228.194 10.285.250.219.195.161 50.360.324.294.270.235 30 30.316.281.249.224.191 10.283.247.217.193.159 50.349.317.286.262.230 10 30.310.277.246.221.188 10.279.245.216.191.158
5-6 AEV-EOLA Obstruction Marker Flameproof, Exd, IIC, IP66 Zone 1 Application: AEV incandescent lighting fixtures are used: To aid aircraft navigation in hazardous locations To mark towers and process columns in petroleum refineries or chemical process plants To indicate the presence of drilling rigs or other industrial facilities Features: Easy to assemble and re-lamp Lightweight, corrosion resistant, copper free aluminium Red fresnel prismatic lens ensures high visibility and avoids glare (other colours also available upon request) Available in single or double units, pipe or base mount versions 1 x M20 entry (other entries available upon request) Standard Materials: Body and guard - Copper free aluminium External Lens - Configurated glass, heat treated and impact resistant Internal Lens - Coloured glass with fresnel configuration Standard Finish: Body and guard - Grey polyurethane Size Ranges: 150W (max) 240/250V Incandescent Compliances: AS2380 Electrical equipment for explosive atmospheres - Flameproof enclosure AS1939 - Degrees of Protection IP66 Certificate of Compliance No. Ex 491 Ordering Information Type Single Unit Pipe Mount Double Unit Pipe Mount Single Base Mount Dimensions: Order Code Entry Size Incandescent Lamp Lamp Holder AEVA-EOLA1* 1 x M20 150W Max E27 AEVA-EOLA2* 1 x M20 150W Max E27 AEVCX-EOLA1* 4 x M20 150W Max E27
5-7 T100A Small Bulkhead Luminaire Flameproof, Exd, IIB, IP66 Zone 1 Application: For use in hazardous areas where space is limited and local lighting is required In areas where low mounting height requires a fixture with a low profile For wall mounting in confined spaces such as inspection pits For mounting in pre-cast recesses Features: Cast aluminium body with flat impact resistant glass, cast guard and mounting feet The lamp housing is separate from the terminal housing which allows direct connection to circuit wiring without the use of high temperature cable. The terminal housing is accessible by means of an inspection cover Internal LPF control gear for fluorescent and HID lamps Three 25mm entries, 1 on each side and 1 in the end Reduced maintenance costs when used with long life HID light sources Standard Materials: Body and guard... Copper free aluminium Lens...Heat resistant borrosilicate glass Standard Finish: Natural Compliances: AS2380 Electrical equipment for explosive atmospheres - Flameproof enclosure AS1939 - Degrees of Protection IP66 Certificate of Compliance No. Ex618 Electrical Rating: Incandescent...100W Mercury vapour... 50W High pressure sodium... 35W Fluorescent (SL type lamp)..18w Fluorescent (PL) type lamp). 9W All types... 240V/50Hz Ordering Information: Lamp Size & Type Cat. No. Temperature Rating 100W Incandescent T100A T3 18W SL type fluorescent T18-SL T6 9W PL type fluorescent T09-PL T6 Dimensions:
5-8 ellk92 Series Fluorescent Fixtures Increased Safety, Exde, IIC, IP66 Zone 1 Application: Suitable for use in areas where hazardous liquids, gases or vapours are present during normal operation Suitable for arduous conditions or extreme environments Ideal for walkways, bridges, tunnels, security lighting, roadways and process plants where reliable lighting is required for safe operation Low profile for use in areas where very low mounting heights or other space restrictions exist Features: Incorporates CEAG designed electronic ballasts which are suitable for use with bi-pin (to IEC 81) fluorescent lamps Electronic ballast provides high luminous efficiency, lower energy consumption and longer service life of the lamps Central locking system operated by standard SW13 hex socket key enables fixture to be opened from single point on fixture housing Diffuser fastened by 10, 20 and 24 latch points respectively on 18W, 36W, and 58W fixtures Diffuser hinges from either side and is also designed to act as a convenient lamp support when open to simplify lamp replacement Automatic disconnect switch ensures the isolation of all exposed components when the fixture is opened Lamp operation on twin lamp fixtures is independent so that failure of one does not affect the other Large internal terminal compartment with twist locking knob on the cover enables ready wiring access Supplied as standard with 2 x M20 metal entries at each end, complete with through wiring facility Wide voltage range Standard Materials: Housing... Glass-mat reinforced polyester Diffuser... Polycarbonate Bi Pin Fluorescent Lamp Electrical Ratings: Operating Voltage AC 110 to 254 V ±10% 47-63HZ DC 110 to 230 V ±10% Lamp configurations 2 x 18W, 1 x 36W, 2 x 36W, 1 x 58W, 2 x 58W Bi-pin 26mm diameter Terminals... L1, L2, L3, L, N, PE 6mm 2 maximum, 1 wire per terminal Ambient Temperature Range... -25 C to +50 C Options: Alternate entry sizes available, consult factory for details Ordering Information: Compliances: EN50014, EN50019, EN50018, Electrical apparatus for potentially explosive atmospheres, General Requirements, Increased Safety e, Flameproof Enclosure d EN60529 Specification for degrees of protection provided by enclosures (IP Code) IP66 PTB ATEX 96 2144 SAA Aus Ex 3558X Type Lamps Rated Power Temp. Catalogue Current Factor Class No. ellk92018/18 2 x 18W 0.18A 0.95 T4 1 2265 875 111 ellk92036 1 x 36W 0.18A 0.95 T4 1 2263 875 103 ellk92036/36 2 x 36W 0.34A 0.95 T4 1 2266 875 111 ellk92058 1 x 58W 0.27A 0.95 T4 1 2264 875 111 ellk92058/58 2 x 58W 0.53A 0.95 T4 1 2267 875 111
5-9 Dimensions & Mounting Accessories Dimensions: ellk92018/18 ellk92036 & ellk92036/36 ellk92058 & ellk92058/58 Mounting Accessories: Note: Supplied as sets of two Ceiling Mount D2 Cat No. 2 2480 102 000 Eye bolt A2 Cat No. 2 2480 002 000 Pipe Clamp Type Pipe Diameter Height H Cat No: R12 38-42mm 85mm 2 2480 462 000 R22 47-50mm 95mm 2 2480 472 000 R32 58-62mm 105mm 2 2480 482 000 Hex Screw S4 Cat No. 2 2480 054 000
5-10 Photometric Data 2 x 18 W Fixture Rated luminous flux of lamps 2 x 18 W = 2,700 Im Light efficiency in operation: 2 x 18 W = 78% Illumination data acc. to LiTG B 30 1 x 36 W Fixture 2 x 36 W Fixture Rated luminous flux of lamps 1 x 36 W = 3,350 lm Light efficiency in operation: 1 x 36 W = 86% Illumination data acc. to LiTG B 30 Rated luminous flux of lamps 2 x 36 W = 6,700 lm Light efficiency in operation: 2 x 36 W = 78% Illumination data acc. to LiTG B 30 1 x 58 W Fixture 2 x 58 W Fixture Rated luminous flux of lamps 1 x 58 W = 5,200 lm Light efficiency in operation: 1 x 58 W = 81% Illumination data acc. to LiTG B 30 Rated luminous flux of lamps 2 x 58 W = 10,400 lm Light efficiency in operation: 2 x 58 W = 72% Illumination data acc. to LiTG B 30
5-11 ellm92 Series Fluorescent Pole Fixtures Increased Safety, Exde, IIC, IP66/67 Zone 1 Application: Suitable for use in areas where hazardous liquids, gases or vapours are present during normal operation Suitable for arduous conditions or extreme environments Ideal for walkways, bridges, security lighting, roadways and process plants where reliable lighting is required for safe operation To provide overhead lighting from pole end mount position Features: Incorporates CEAG designed electronic ballasts which are suitable for use with bi-pin (to IEC 81) fluorescent lamps Electronic ballast provides high luminous efficiency, lower energy consumption and longer service life of the lamps Integral pole mounting sleeve recessed into housing for 44mm pipe (1 1/4 nominal bore) Large terminal compartment readily accessible and located beneath pole mount Central locking system operated by standard SW13 hex socket key enables fixture to be opened from one point on housing Diffuser fastened by 10, 20 and 24 latch points respectively on 18W, 36W and 58W fixtures Diffuser hinges from either side and is also designed to act as a convenient lamp support when open to simply lamp replacement Automatic disconnect switch ensures the isolation of all exposed components when the fixture is opened Lamp operation on twin lamp fixtures is independent so that failure of one does not affect the other Supplied with 25mm cable gland for 8-17mm cable Wide voltage range Standard Materials: Housing... Glass-mat reinforced polyester Diffuser... Polycarbonate Electrical Ratings: Operating Voltage AC 110 to 254 V ±10% 47-63HZ DC 110 to 230 V ±10% Lamp configurations... 2 x 18W, 2 x 36W Bi-pin 26mm diameter Terminals... L1, N, PE, 2 x 6mm 2 1 wire per terminal Ambient Temperature Range... -25 C to +50 C Options: Accessory kit for single ended through wiring comprising adaptor with 2 x M25 cable glands......cat No. 2 2218 602 000 Ordering Information: Bi Pin Fluorescent Lamp Compliances: EN50014, EN50019, EN50018, Electrical apparatus for potentially explosive atmospheres, General Requirements, Increased Safety e, Flameproof Enclosure d EN60529 Specification for degrees of protection provided by enclosures (IP Code) IP66 PTB96 ATEX 2144 SAA Aus Ex 3558X Type Lamps Rated Power Temp. Catalogue Current Factor Class No. ellm92018/18 2 x 18W 0.18A 0.95 T4 1 2268 875 101 ellm92036/36 2 x 36W 0.34A 0.95 T4 1 2269 875 101
5-12 Dimensions & Photometric Data Dimensions: ellm Pole Mount Internal View of Terminal Compartment Standard Through wiring option Mounting Accessories: Wall Mount Bracket W26 Cat No. 2 2485 027 000 Photometric Data: 2 x 18 W Fixture 2 x 36 W Fixture Rated luminous flux of lamps 2 x 18 W = 2,700 Im Light efficiency in operation: 2 x 18 W = 6,700 Im Illumination data acc. to LiTG B 30 Rated luminous flux of lamps 2 x 36 W = 6,700 lm Light efficiency in operation: 2 x 36 W = 78% Illumination data acc. to LiTG B 30
5-13 ellk92036/36nib Emergency Fixtures Application: Suitable for use in areas where hazardous liquids, gases or vapours are present during normal operation Suitable for arduous conditions or extreme environments In applications where lighting must be maintained under emergency conditions to ensure safe evacuation of personnel Ideal for walkways, bridges, tunnels, roadways and process plants where reliable lighting is required for safe operation Features: Incorporates CEAG designed electronic ballasts which are suitable for use with bi-pin (to IEC 81) fluorescent lamps Electronic ballast provides high luminous efficiency, lower energy consumption and longer service life of the lamps Intelligent microelectronic controller monitors battery charge cycle eliminating overcharge and ni-clad memory effect, extending battery life Battery charge level indicated by green LED display Indicates when an operating duration test is necessary at six month intervals as required by safety regulations Indication provided after duration test if a malfunction is apparent Battery set can be safely replaced within hazardous environment Emergency operation can be set for 1.5 or 3 hour duration Central locking system operated by standard SW13 hex socket key enables fixture to be opened from one point of housing Diffuser fastened by 10 and 20 latch points respectively on 18W and 36W fixtures Diffuser hinges from either side and is also designed to act as a convenient lamp support when open to simplify lamp replacement Automatic disconnect switch ensures the isolation of all exposed components when the fixture is opened Lamp configuration on twin lamp fixtures is dependent so that failure of one does not affect the other Incorporates inhibit function set by internal wire terminal link to disable emergency operation for when power is intentionally removed. Link can also be wired as external switch, for up to 10 fixtures per switch Increased Safety, Exdem ib, IIC, IP66 Zone 1 Standard Materials: Housing... Glass-mat reinforced polyester Diffuser... Polycarbonate Electrical Ratings: Operating Voltage AC 220 to 254 V ±10% 47-63HZ Lamp configurations 2 x 18W, 2 x 36W Bi-pin 26mm diameter Terminals... L1, L2, L3, L, N, PE 6mm 2 maximum, 1 wire per terminal Ambient Temperature Range... -5 C to +50 C Emergency operation single lamp for 1.5 hour or 3 hour, set by internal wire terminal link Bi Pin Fluorescent Lamp Compliances: EN500 14, EN50019, EN50018, EN50028, EN50020 Electrical apparatus for potentially explosive atmospheres, General Requirements, Increased Safety e, Flameproof Enclosure d, Encapsulation m, Intrinsic Safety i EN60529 Specification for degrees of protection provided by enclosures (IP Code) IP66 PTB96 ATEX2144 SAA AUS Ex 3558X Ordering Information: Ceiling Mounted Emergency Fittings Type Lamps Rated Power Temp. Catalogue ellk92018/18nib 2 x 18W Current 0.23A Factor 0.95 ind Class T4 No. 1 2260 879 111 ellk92036/36nib 2 x 36W 0.4A 0.95 ind T4 1 2261 879 111 Pole Mounted Emergency Fitting Type Lamps Rated Power Temp. Catalogue Current Factor Class No. ellm92018/18nib 2 x 18W 0.23A 0.95 ind T4 1 2273 879 101
5-14 Features, Dimensions & Photometric Data Operation: Status of the battery charge cycle is indicated by a series of five green Light Emitting Diodes (LED), each of which represents 20% of battery capacity. The level of charge attained is indicated by the leading green LED which flashes. The charge cycle is complete when all five green LED s are on. Emergency operation commences on mains failure or when the main supply is switched off. During emergency operation the remaining battery capacity is indicated by the number of LEDs which are on. The red LED begins flashing after six months from the last successful emergency duration test, or when during battery discharge a defective power supply or fluorescent lamp is detected. The red LED will continue to flash until a successful duration test is completed. Battery temperature is monitored during charge cycle Microelectronic controller monitors charge cycle, eliminating over charge and Ni-cad memory effect Charge status indicated by green LED display Flashing red LED indicates when an operating duration test is necessary at six month intervals as required by safety regulations Red LED continues to flash after duration test if a malfunction is apparent Dimensions: ellk92018/18 Ni Ceiling Mount - Emergency Battery set is replaceable within hazardous area ellk92036/36 Ni Ceiling Mount - Emergency ellm92018/18 Ni Pole Mount - Emergency Mounting Accessories: Refer to pages 5-9 and 5-12 Photometric Data: Emergency Operation: Apply the following luminous flux factors when determining performance under emergency single lamp operation: 18 W = approx. 1.5 h 90% / 3.0 h 45% 36 W = approx. 1.5 h 45% / 3.0 h 25% Rated luminous flux of lamps: 1 x 18 W = 1,350 Im 1 x 36 W = 3,350 lm
5-15 AEVF Series Explosionproof Fluorescent Fixture Application: AEVF Luminaires are used to illuminate areas where hazardous liquids, fumes or gases are present. Areas such as: Spray Booths Drum Filling Areas Process Plants Combustible dusts present Features: Luminaire has been designed to utilise the latest technology of compact fluorescent lamps Cast aluminium body with screw threaded construction Integral control gear in fully accessible compartment Stainless steel guard and reflector Mounting feet facilitate mounting on either wall or ceiling Ease of installation Reduced initial cost Reduced maintenance cost Can be supplied with special Emergency Exit sign Can be supplied with external Emergency Battery Pack for 2 hours standby lighting Standard Materials: Body... copper free aluminium Stainless steel guard and reflector Standard Finish: Grey polyurethane Electrical Rating: 240V 50Hz Twin and single lamps PL18, PL24, PL36. 18, 24 and 36W respectively Compliances: AS2380 Electrical equipment for explosive atmospheres - Flameproof enclosure AS2236 Electrical equipment for explosive atmospheres - Dust excluding Ignition proof AS1939 Degrees of Protection IP66 Certificate of Compliance No. Ex933X Options: Emergency Exit Sign... NCE Emergency Battery Pack...NC Pole Mount...PM Flameproof, Exd, IIB, IP66 Zone 1 Combustible Dust Zone 21 & 22 Ordering Information: Cat. No. No. & Size of Lamps Entries Temp Rating AEVF118 1 x 18W 2 x 25mm T5 AEVF136 1 x 36W 2 x 25mm T5 AEVF218 2 x 18W 2 x 25mm T5 AEVF236 2 x 36W 2 x 25mm T5 Utilisation factors: UF (F) SHR NOM = 1.75 Room reflectance Room Index C W F.60.75.801.00 1.251.50 2.002.50 3.00 4.00 5.00.70.50.20.22 N/A.24.26.29.31.35.37.38.40.42.30.19 N/A.21.23.26.28.32.34.36.38.40.10.14 N/A.17.20.23.26.29.32.34.36.38.50.50.20.14 N/A.23.25.28.30.33.35.36.38.39.30.18 N/A.20.22.25.27.30.32.34.36.38.10.15 N/A.17.19.22.25.28.30.32.35.36.30.50.20.20 N/A.22.24.26.28.31.32.34.36.37.30.15 N/A.18.21.24.26.29.31.32.34.35.10.13 N/A.16.19.22.24.27.29.31.33.34.00.00.00.13 N/A.16.17.20.22.25.26.28.30.31 Rating: Photometrically tested without ceiling board. Multiply values by service corrections factors. Calculated in accordance with CIBS Technical Memorandum No. 5 1980. Dimensions: (mm)
5-16 NDFA Heavy Duty Fluorescent Fixtures Application: For use in locations where a concentration of flammable gases or vapours may occur as the result of an abnormal situation Suitable for DIP locations such as grain handling facilities or other areas where hazardous dusts fibres & flyings are present and may become suspended in the atmosphere or settle on equipment or ledges Ideal for walkways, bridges, tunnels, security lighting, roadways and process plants where reliable lighting is required for safe operation For arduous conditions or extreme environments Low profile for use in areas where very low mounting heights or other space restrictions make installation difficult Features: Three different mounting arrangements available: Ceiling mount Pipe mount Hanger mount Corrosion resistant FRP housing makes it ideal for installations in areas where corrosive and / or wet conditions exist during normal plant operation Noryl clips secure prismatic diffuser to the body to ensure reliable sealing while still allowing ease of relamping and maintenance A reliable seal between body and diffuser is provided by a closed cell non aging rubber gasket Prismatic Diffuser eliminates glare without diminishing the amount of illuminance Reflector / gear tray is suspended on hangers for ease of installation and maintenance Standard Materials: Body... Grey FRP (Fibreglass reinforced polyester) Prismatic Diffuser... Moulded polycarbonate Gasket... Polyurethane foam Quick Release Clips... Noryl Cable entry...brass Non-Sparking, Exn, IIC, IP66/67 Zone 2 Combustible Dust Zone 21 & 22 Robust diffuser clips Standard Finishes: Body...Grey Prismatic Diffuser... Clear Options: (Refer to ordering information) Through wiring... Terminal block at each end of the fixture internally wired (4mm 2 ) to facilitate ease of connection Hanger Mounting... Eye Bolts allow for suspension of the fixture by either chain or steel cable Pipe Mounting.. Brackets to allow suspension from a pipe stanchion or wall bracket Emergency Pack... integral power pack to give 2 hours standby lighting in the event of a power supply failure Non standard voltages Stainless Steel quick-release clips Other entries available upon request Brass entry Electrical Ratings: 240 V, 50 Hz standard. Other voltages and frequencies on request 18W, and 36W Temperature rating... Exn - T3, DIP - T5 Compliances: Australian Standard 2238 Electrical Equipment for explosive atmospheres... Non-sparking apparatus. Type of Protection n. Certificate of Compliance Ex1153x Australian Standard 2236 Electrical Equipment for explosive atmospheres... Dust-excluding ignitionproof enclosure. Certificate of Compliance Ex1149DIP Australian Standard 1939 Degrees of Protection of electrical equipment IP66
5-17 Ordering Information N D F A 1M 236 8 D M N S E Product Identifier - NDFA Entry Size 1M- M20 2M- M25 1N - 1/2" NPT 2N - 3/4" NPT Wattage 118-1x18 218-2x18 136-1x36 236-2x6 Voltage & Frequency 1-110V / 60Hz 2-120V / 60Hz 3-220V / 50Hz 4-220V / 60Hz 5-230V / 50Hz 6-240V / 50Hz 8- Electronic Ballast - 220-245V / 47-63Hz Cable Entries 0 - No through entry T - Through entries S - Single through entries (2 entries on one side) D - Double through entries (2 entries on one side) Dimensions: Lamp A B Size mm mm 18W 660 550 36W 1275 800 Types of Entry P - Plastic M - Metal Emergency 0 - Standard N - Emergency Securing Clips 0 - Plastic S - Stainless Steel Exit Sign 0 - None E - Exit Sign Ceiling Mount Bracket Mounting Accessories : fixtures supplied complete with ceiling mount brackets. Order pipe clamps and eye bolts separately if required. Two required per fixture. Pipe Clamp Pipe Diameter Height H Cat No: 38-42mm 85mm UN8-43 47-50mm 95mm UN8-51 58-62mm 105mm UN8-63 Eye bolt Cat No. EBM6SS Photometric Data: C0 C90 cd/klm Typical luminous flux of lamps 1 x 18 W = 1,350 Im, 2 x 18 W = 2,700 Im 1 x 36 W = 3,350 lm, 2 x 36 W = 6,700 lm
5-18 nllk Heavy Duty Fluorescent Fixtures Application: For use in locations where a concentration of flammable gases or vapours may occur as the result of an abnormal situation Suitable for DIP locations such as grain handling facilities or other areas where hazardous dusts fibres & flyings are present and may become suspended in the atmosphere or settle on equipment or ledges Ideal for walkways, bridges, tunnels, security lighting, roadways and process plants where reliable lighting is required for safe operation For arduous conditions or extreme environments Low profile for use in areas where very low mounting heights or other space restrictions make installation difficult Features: Electronic ballast provides high luminous efficiency, lower energy consumption and longer service life of the lamps Emergency operation can be set for 2 hour duration Central locking system operated by standard SW13 hex socket key enables fixture to be opened from one point of housing Diffuser fastened by 10 and 20 latch points respectively on 18W and 36W fixtures Diffuser hinges from either side and is also designed to act as a convenient lamp support when open to simplify lamp replacement Standard Materials: Body... Grey FRP (Fibreglass reinforced polyester) Diffuser... Moulded polycarbonate Gasket... Polyurethane foam Cable entry...brass Standard Finishes: Body...Grey Prismatic Diffuser... Clear Non-Sparking, Exn, IIC, IP66/67 Zone 2 Combustible Dust Zone 21 & 22 Options: (Refer to ordering information) Through wiring... Terminal block at each end of the fixture internally wired (4mm 2 ) to facilitate ease of connection Hanger Mounting... Eye Bolts allow for suspension of the fixture by either chain or steel cable Pipe Mounting.. Brackets to allow suspension from a pipe stanchion or wall bracket Emergency Pack... integral power pack to give 2 hours standby lighting in the event of a power supply failure Other entries available upon request Electrical Ratings: 240 V, 50 Hz standard. Other voltages and frequencies on request 18W, and 36W Temperature rating. - Exn - T4 Compliances: Australian Standard 2238 Electrical Equipment for explosive atmospheres... Non-sparking apparatus. Type of Protection n. Certificate of Compliance - Aus Ex 3723 - PTB 98 ATEX 2208 (excluding Emergency Luminaires) Australian Standard 1939 Degrees of Protection of electrical equipment IP66
5-19 Ordering Information & Dimensions Ordering Information Type. Lamps Temp Class at 40 0 C Circuit Catalogue No. Standard Fixtures nllk98018/18 2 x 18W T4 Electronic 13465218021 nllk98036 1 x 36W T4 Electronic 13465136021 nllk98036/36 2 x 36W T4 Electronic 13465236021 nllk98058 1 x 58W T4 Electronic 13465158021 nllk98058/58 2 x 58W T4 Electronic 13465258021 Emergency Fixtures nllk98018/18n 2 x 18W T4 Electronic nllk1m2188dmn00 nllk98036n 1 x 36W T4 Electronic nllk1m1368dmn00 nllk98036/36n 2 x 36W T4 Electronic nllk1m2368dmn00 Accessories Type Catalogue No. Galvanised Eyebolt A2 2 2480 002 000 Stainless Steel Ceiling Bracket D92 2 2480 092 000 Pipe Clamps 43mm UN8-43SP Pipe Clamps 51mm UN8-51P Options Type Catalogue No. Diffuser c/w EXIT Sign Add E to Cat. No. Dimensions
5-20 AEVBH Large Bulkhead Luminaire Flameproof, Exd, IIC, IP66 Zone 1 Combustible Dust Zone 21 & 22 Application: The AEVBH bulkhead luminaire is suitable for use with HID, fluorescent and incandescent light sources in Zone 1 and Zone 21 & 22 hazardous locations Ideal for areas with low headroom or mounting height where it allows the use of energy efficient HID light sources For wall mounting in inspection pits and similar wall mounting application where the adjustable reflector allows the light to be directed Features: Low profile (180mm) enables it to be mounted in tight spots Adjustable reflector allows direction of light in specific directions Available with a variety of light sources including energy efficient HPS Reduced maintenance costs when used with long-life HID light sources Standard Materials: Body and dome cover...... Copper free aluminium Diffuser...... Heat and impact resistant glass Guard... Stainless steel wire Reflector... Stainless steel Standard Finish: Grey polyurethane Electrical Rating: 240V 50Hz 200W incandescent 175W mercury vapour 150W high pressure sodium 2 x 11W fluorescent 175W metal halide Option: Pipe mounting... Add suffix J Corro free powder polyester finish...information on request Compliances: AS2380 - Electrical equipment for explosive atmospheres - Flameproof enclosure AS2236 - Electrical equipment for explosive atmospheres - Dust excluding ignition proof AS1939 - Degrees of Protection IP66 Certificate of Compliance No. Ex647 Ordering Information: Cat. No. Lamp Lamp Entry Temperature Size Type Size Rating AEVBH 22201 200W Incandescent 25mm T3 AEVBH 42051 50W HPS 25mm T4 AEVBH 42071 70W HPS 25mm T4 AEVBH 42101 100W HPS 25mm T4 AEVBH 42151 150W HPS 25mm T3 AEVBH 52021 2 x 11W PL Fluorescent 25mm T6 AEVBH 82051 50W Mercury Vapour 25mm T3 AEVBH 82081 80W Mercury Vapour 25mm T3 AEVBH 82101 100W Mercury Vapour 25mm T3 AEVBH 82121 125W Mercury Vapour 25mm T3 AEVBH 82171 175W Mercury Vapour 25mm T3 AEVBH 92171 175W Metal Halide 25mm T3 Dimensions:
5-21 EVM Hazard Gard H.I.D. Fixtures Integral Ballast Factory Sealed Application: EVM Hazard Gard lighting fixtures are used in areas, both indoors and outdoors where long lamp life and low maintenance costs are desired Heavy process industries having environments where flammable or explosive vapours or gases, or where combustible dusts are present Features: Fixture is factory wired; power is fed through "wireless" connection block which serves as a mechanical seal between entry and ballast compartment. The result is fast, easy installation with improved reliability and safety, enabling cost effective installation and maintenance Dome and angle reflectors made of Krydon - will not rust, corrode, dent, chip or peel High bay Alzak aluminum reflectors are available for mounting heights above 6m. Uniform attractive appearance in all wattages and mounting styles Configurated glass reduces glare improving light distribution Certified for operation in elevated ambient temperatures of up to 50 o C Wide range of light sources to meet specific lighting needs - 80, 100, 125, 175, 250 & 400W mercury vapour (MV); 175, 250 & 400W metal halide (MH); 70, 100, 150, 250W, 400W high pressure sodium (HPS) Four mounting types to suit all lighting layout... pendant, ceiling, wall bracket, and stanchion Integral ballasts... separate ballasts are not required Lowest installed cost Standard Materials: Mounting modules, cover, ballast housing, guard, globe ring - copper free aluminium Glass... Heat and impact resistant, configurated glass Lamp socket... porcelain with stainless steel screw shell Reflectors... dome and angle... fibreglass reinforced polyester (Krydon ); High Bay, Alzak aluminium External Hardware stainless steel Flameproof, Exd, IIB or IIC, IP66 Zone 1 Combustible Dust Zone 21 & 22 Standard Finishes: Copper free aluminium... Grey polyurethane Krydon... natural white Alzak... natural aluminium Options (Refer to ordering Information) For Group IIC applications Fuse... To protect ballast and capacitors against line surges May be ordered with or without guard Instant restrike ballast - enables a hot HPS lamp to immediately restrike after momentary loss of arc due to voltage fluctuation or power loss. Available for use with 50-150W LX HPS only Electrical Ratings: 240 VAC 50Hz 70 to 400 Watts Alternate operating voltages available, see ordering information Entry Sizes: 20, 25mm hubs on ceiling, pendant and wall mounted, 1 1/4 BSP on Stanchion Mount Alternate entries available, see ordering information Compliances: AS2380 Electrical equipment for explosive atmospheres - Flameproof enclosure AS2236 - Electrical equipment for explosive atmospheres. Dust excluding ignition proof AS1939 - Degrees of Protection IP66 Certificate of Compliance No. Ex434
5-22 Ordering Information E V M A H 1 M 40 B 6 0 0 0 0 Product Identifier EVMA - Pendant Mount EVMB - Wall Mount EVMC - Ceiling Mount EVMJ - Stanchion Mount Lamp Type S - HPS H - MV M - MH Gas Group B - Group IIB C - Group IIC Entry Size 1-20mm / 1/2" 2-25mm / 3/4" 3-32mm / 1" 4-1 1/4 " Entry Thread M - Metric N - 25mm / 3/4" B - BPS Wattage 07-70W 08-80W 10-100W 12-125W 15-150W 17-175W 25-250W 40-400W Voltage & Frequency 2-120V/60Hz 3-220V/50Hz 4-220V/60Hz 5-230V/50Hz 6-240V/50Hz Special Options 0 - Standard 1 - Special Instant Restrike 0 - None I - IR Special Options O - Standard S - Fuse Options 0 - Standard 1 - Offshore Paint
5-23 Ordering Information Pendant Wall Bracket Ceiling Stanchion Entry With Guard With Guard WIth Guard With Guard Watts Size Cat. No. Cat. No. Cat. No. Cat. No. Mercury Vapour - High Power Factor 80 20mm EVMA81M08B60000 EVMB81M08B60000 EVMC81M08B60000 25mm EVMA82M08B60000 EVMB82M08B60000 EVMC82M08B60000 1 1/4" BSP EVMJ84B08B60000 100 20mm EVMA82M10B60000 EVMB81M10B60000 EVMC81M10B60000 25mm EVMA82M10B60000 EVMB82M10B60000 EVMC82M10B60000 1 1/4" BSP EVMJ84B10B60000 125 20mm EVMA81M12B60000 EVMB81M12B60000 EVMC81M12B60000 25mm EVMA82M12B60000 EVMB82M12B60000 EVMC82M12B60000 1 1/4" BSP EVMJ84B12B60000 175 20mm EVMA81M17B60000 EVMB81M17B60000 EVMC81M17B60000 25mm EVMA82M017B6000 EVMB82M17B60000 EVMC82M17B60000 1 1/4" BSP EVMJ84B17B60000 250 20mm EVMA81M25B60000 EVMB81M25B60000 EVMC81M25B60000 25mm EVMA82M25B60000 EVMB82M25B60000 EVMC82M25B60000 1 1/4" BSP EVMJ84B25B60000 400 20mm EVMA81M40B60000 EVMB81M40B60000 EVMC81M40B60000 25mm EVMA82M40B60000 EVMB82M40B60000 EVMC82M40B60000 1 1/4" BSP EVMJ84B40B60000 High Pressure Sodium - High Power Factor 70 20mm EVMA41M07B60000 EVMB41M07B60000 EVMC41M07B60000 25mm EVMA42M07B60000 EVMB42M07B60000 EVMC42M07B60000 1 1/4" BSP EVMJ44B07B60000 100 20mm EVMA41M10B60000 EVMB41M10B60000 EVMC41M10B60000 25mm EVMA42M10B60000 EVMB42M10B60000 EVMC42M10B60000 1 1/4" BSP EVMJ44B10B60000 150 20mm EVMA41M15B60000 EVMB41M15B60000 EVMC41M15B60000 25mm EVMA42M15B60000 EVMB42M15B60000 EVMC42M15B60000 1 1/4" BSP EVMJ44B15B60000 250 20mm EVMA41M25B60000 EVMB41M25B60000 EVMC41M25B60000 25mm EVMA42M25B60000 EVMB42M25B60000 EVMC42M25B60000 1 1/4" BSP EVMJ44B25B60000 400 20mm EVMA41M40B60000 EVMB41M40B60000 EVMC41M40B60000 25mm EVMA42M40B60000 EVMB42M40B60000 EVMC42M40B60000 1 1/4" BSP EVMJ44B40B60000 Metal Halide - High Power Factor Ballast 175 20mm EVMA91M17B60000 EVMB91M17B60000 EVMC91M17B60000 25mm EVMA92M17B60000 EVMB92M17B60000 EVMC92M17B60000 1 1/4" BSP EVMJ94B17B60000 250 20mm EVMA91M25B60000 EVMB91M25B60000 EVMC91M25B60000 25mm EVMA92M25B60000 EVMB92M25B60000 EVMC92M25B60000 1 1/4" BSP EVMJ94B25B60000 400 20mm EVMA91M40B60000 EVMB91M40B60000 EVMC91M40B60000 25mm EVMA92M40B60000 EVMB92M40B60000 EVMC92M40B60000 1 1/4" BSP EVMJ94B40B60000 Fixtures are supplied as standard suitable for 240/50 hz operation. For other voltages please specify required voltage. Ceiling and bracket mounts have 4 hubs; 3 are plugged
5-24 Accessories Dome Reflector Cat.No. RD739 Lamp Receptacle Cat. No. EV62 All sizes Glass Assembly Watts Cat. No. Up to 175 EV7302 250/400 EV7404 Guard Watts Cat. No. Up to 175 EV503 250/400 EV5140 30 Angle Reflector Cat.No. RA739 Ceiling Mount Entry Cat. No. 20mm EV16 25mm EV26 Wall Mount Entry 20mm 25mm Cat. No. EV16 + EV87 EV26 + EV87 High Bay Reflector Cat.No. EV3912 Pendant Mount Entry Cat. No. 20mm EVMP2 25mm EVMP3 Stanchion Mount Entry Cat. No. 1 1/4" BSP EVMJ4 Temperature Classification: 40 o c Ambient Power Mercury High Pressure Metal Rating (W) Vapour (MV) Sodium (HPS) Halide (MH) 70 - T6-80 T6 - - 100 T4 T4-125 T4 - - 150 - T4-175 T3 - T4 250 T3 T3 T3 400 T3 T3 T3 50 o c Ambient Power Mercury High Pressure Metal Rating (W) Vapour (MV) Sodium (HPS) Halide (MH) 70 - T6-80 T6 - - 100 T4 T4-125 T4 - - 150 - T4-175 T3 - T4 250 T3 T3 T3 400 T3 T3 T3
5-25 Accessories Wall Mount Pendant Mount Ceiling Mount Stanchion Mount 80, 100, 125, 175, MV 70, 100, 150W HPS 250W & 400W 175 MH MV, HPS, MH All Type A B C D E EVMA 553 610 499 564 618 EVMBX 635 693 581 646 697 EVMCX 553 610 499 564 618 EVMJ 543 594 573
5-26 EVME Hazard Gard H.I.D. Fixtures Integral Ballast Flameproof, Exde, IIB or IIC, IP66 Zone 1 Combustible Dust Zone 21 & 22 Application: EVME Hazard Gard lighting fixtures are used in areas, both indoors and outdoors where long lamp life and low maintenance costs are desired Heavy process industry environments where flammable or explosive vapours or gases, or combustible dusts are present Features: Indirect cable entry into a separate Exe termination enclosure ensures ease of installation Dome and angle reflectors made of Krydon - will not rust, corrode, dent, chip or peel High bay Alzak aluminium reflectors are available for mounting heights above 6m Uniform attractive appearance in all wattages and mounting styles Configurated glass reduces glare improving light distribution Certified for operation in elevated ambient temperatures of up to 50 o C Wide range of light sources to meet specific lighting needs - 80, 100, 125, 175, 250 & 400W mercury vapour (MV); 175, 250 & 400W metal halide (MH); 70, 100, 150, 250W, 400W high pressure sodium (HPS) Standard ceiling mount luminaires can be adapted for wall, pendant or stanchion mount by using brackets (order brackets seperatetly) Integral ballasts... separate ballasts are not required Lowest installed cost Standard Materials: Mounting modules, cover, ballast housing, guard, globe ring - copper free aluminium Glass... Heat and impact resistant, configurated glass Lamp socket... porcelain with stainless steel screw shell Reflectors... dome and angle... fibreglass reinforced polyester (Krydon ); High Bay, Alzak aluminium External Hardware stainless steel Standard Finishes: Copper free aluminium... Grey polyurethane Krydon... natural white Alzak... natural aluminium Options (Refer to ordering Information) For Group IIC applications Fuse... To protect ballast and capacitors against line surges Instant restrike ballast - enables a hot HPS lamp to immediately restrike after momentary loss of arc due to voltage fluctuation or power loss. Available for use with 50-150W LX HPS only Alternate entries available - please consult factory Electrical Ratings: 240 VAC 50Hz 70 to 400 Watts Alternate operating voltages available, see ordering information Entry Sizes: 20, 25mm hubs on ceiling, pendant and wall mounted, 1 1/4 BSP on Stanchion Mount Alternate entries available, see ordering information Compliances: EN50014 EN50018 EN50019 EN60529 EN60598 AS/NZS: 60079.0.2000 AS/NZS: 60079.1.2000 AS/NZS: 60079.7.2002 Certificate of Compliance No. PTB ATEX1056 Aus EX Pending Ambient Temperature -50 0 to 55 0 C
5-27 Ordering Information E V M E H 1 M 40 B 6 0 0 0 0 Product Identifiers Gas Group B - Group IIB C - Group IIC Lamp Type S - HPS H - MV M - MH Entry Size 1-20mm / 1/2" 2-25mm / 3/4" 3-32mm / 1" 4-1 1/4 " Entry Thread M - Metric N - 25mm / 3/4" B - BPS Wattage 07-70W 08-80W 10-100W 12-125W 15-150W 17-175W 25-250W 40-400W Voltage & Frequency 2-120V/60Hz 3-220V/50Hz 4-220V/60Hz 5-230V/50Hz 6-240V/50Hz Special Options 0 - Standard 1 - Special Instant Restrike 0 - None I - IR Special Options O - Standard S - Fuse Options 0 - Standard 1 - Offshore Paint
5-28 Ordering Information Mercury Vapour (M/V) Wattage T Rating Cat No. 80W T6 EVMEH1M08B60000 100W T5 EVMEH1M10B60000 125W T4 EVMEH1M12B60000 175W T4 EVMEH1M17B60000 250W T3 EVMEH1M25B60000 400W T3 EVMEH1M40B60000 High Pressure Sodium (HPS) Wattage T Rating Cat No. 70W T6 EVMES1M07B60000 100W T4 EVMES1M10B60000 150W T4 EVMES1M15B60000 250W T3 EVMES1M25B60000 400W T3 EVMES1M40B60000 High Metal Halide (MH) Wattage T Rating Cat No. 70W T6 EVMEM1M07B60000 100W T4 EVMEM1M10B60000 150W T4 EVMEM1M15B60000 175W T4 EVMEM1M17B60000 250W T3 EVMEM1M25B60000 400W T3 EVMEM1M40B60000 * Please refer to table for other possible configurations Mounting Brackets (order seperately) Pendant Mount Cat No. M20 EVMEPM1 M25 EVMEPM2 1/2" NPT Clearance Hole EVMEPN1 3/4" NPT Clearance Hole EVMEPN2 Wall Mount M20 Thread M25 Thread Stanchion Mount Cat No. EVMEWM1 EVMEWM2 Cat No. 2" Slipfitter Pipe EVMEJ 1 1/4" BSP Thread EVMEJB4 1 1/2" NPT Thread EVMEJN5
5-29 Accessories Dome Reflector Cat.No. RD739 Glass Assembly Watts Cat. No. Up to 175 EV7302 250/400 EV7404 Wall Bracket Cat No. EVMEW 30 Angle Reflector Cat.No. RA739 Guard Watts Cat. No. Up to 175 EV503 250/400 EV5140 Stanchion Bracket Cat No. EVMEJ High Bay Reflector Cat.No. EV3912 Lamp Holder Watts Cat. No. Up to 125 EVMVS62600-SA 150 to 400 EVMVS12850-SA Pendant Bracket Cat No. EVMEP
5-30 Dimensions Wall Mount Pendant Mount Ceiling Mount Stanchion Mount
5-31 Fixture With Globe and Without Guard Lamp: 100W mercury vapour - (MV) Total bare lamp lumens: 4200 Fixture With Globe, Dome Reflector and Without Guard Lamp: 100W mercury vapour - (MV) Total bare lamp lumens: 4200 NOTE: Photometric data was developed using a 100 watt diffuse mercury vapour lamp (4200 lumens). For other diffuse lamps, use the following conversion factors (multipliers): 175W MV - 2.05; 70W MH - 1.33; 100W MH - 1.85; 175W MH - 3.3. Multipliers are for use with candela curve only. Luminaire Spacing ratio is 1.30. Coefficient of Utilisation Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff.Ceil. Wall 1 2 3 4 5 50.694.584.503.439.386 80 30.644.516.428.361.311 10.600.459.369.302.253 50.660.556.479.418.368 70 30.615.493.410.347.297 10.572.441.355.291.244 50.596.501.432.377.334 50 30.559.450.375.317.274 10.526.405.328.270.227 50.538.451.389.339.302 30 30.509.410.342.290.250 10.481.373.302.249.210 50.485.405.349.305.271 10 30.461.371.310.263.223 10.439.341.277.228.193 0 0.410.313.251.204.171 % Reflectance Room Cavity Ratio Eff.Ceil. Wall 6 7 8 9 10 50.347.312.282.259.230 80 30.273.241.214.192.166 10.220.192.165.147.125 50.331.298.270.248.220 70 30.262.231.206.185.162 10.211.184.160.143.121 50.300.272.246.227.203 50 30.241.212.190.172.150 10.197.171.149.134.113 50.272.245.225.207.185 30 30.222.196.175.158.138 10.183.158.139.124.105 50.246.224.203.188.169 10 30.202.180.160.146.127 10.168.147.129.115.096 0 0.148.128.111.099.082 NOTE: Photometric data was developed using a 100 watt diffuse mercury vapour lamp (4200 lumens). For other diffuse lamps, use the following conversion factors (multipliers): 175W MV - 2.05; 70W MH - 1.33; 100W MH - 1.85; 175W MH - 3.3. Multipliers are for use with candela curve only. Luminaire spacing ratio is 1.25. Coefficient of Utilisation Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff.Ceil. Wall 1 2 3 4 5 50.715.637.570.509.458 80 30.688.596.521.455.401 10.655.562.483.413.359 50.699.624.560.500.448 70 30.675.586.514.450.396 10.652.556.478.410.356 50.668.598.539.481.434 50 30.648.568.500.438.388 10.631.540.468.404.353 50.640.576.519.465.420 30 30.624.550.487.428.379 10.609.527.459.398.348 50.615.554.502.450.407 10 30.602.553.474.418.372 10.589.514.450.391.343 0 0.575.500.436.377.329 % Reflectance Room Cavity Ratio Eff.Ceil. Wall 6 7 8 9 10 50.414.375.340.313.275 80 30.358.319.286.259.222 10.318.282.247.222.187 50.407.369.335.308.271 70 30.354.315.283.256.222 10.315.278.246.221.187 50.394.358.325.229.264 50 30.347.309.278.252.217 10.312.275.244.219.185 50.383.346.316.292.257 30 30.340.304.273.248.214 10.308.272.242.217.183 50.371.338.307.284.251 10 30.333.299.268.244.210 10.304.269.240.215.181 0 0.292.257.227.204.170
5-32 Isolux Chart: Fixture With Globe and 30 0 Angle Reflector, Without Guard Lamp: 100W diffuse mercury vapour (MV) Total bare lamp lumens: 4,200 Fixture With Globe and Without Guard Lamp: 150W high pressure sodium (HPS) Total bare lamp lumens: 16,000 NOTE: Photometric data was developed using a 100 watt diffuse mercury vapour lamp (4200 lumens). For other diffuse lamps, use the following conversion factors (multipliers): 175W MV - 2.05; 70W MH - 1.33; 100W MH - 1.85; 175W MH - 3.3. Illumination in footcandles on work plane 3m below light centre. Multiply by factor shown to convert to other mounting heights Height (m) Factor Height (m) Factor 1.8 2.78 2.7 1.23 2.1 2.04 3.3 0.83 2.4 1.56 3.7 0.70 NOTE: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16,000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS -.25; 70W HPS -.40; 100W HPS -.59. Multipliers are for use with candela curve only. Luminaire spacing ratio is 0.80. Coefficient of Utilisation Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff.Ceil. Wall 1 2 3 4 5 50.695.579.494.410.382 80 30.644.509.417.326.305 10.599.450.356.262.246 50.659.549.469.387.363 70 30.613.484.397.311.291 10.570.431.341.251.236 50.592.491.419.344.237 50 30.555.439.360.279.265 10.522.393.312.229.218 50.531.438.373.304.292 30 30.502.396.325.250.240 10.474.358.284.207.200 50.476.390.331.267.260 10 30.451.355.291.222.217 10.429.325.257.184.181 0 0.399.295.230.159.159 % Reflectance Room Cavity Ratio Eff.Ceil. Wall 6 7 8 9 10 50.342.306.278.265.233 80 30.266.234.209.198.168 10.212.184.160.153.127 50.324.292.265.253.222 70 30.254.223.201.191.163 10.202.176.155.149.123 50.292.263.240.231.203 50 30.232.203.184.177.150 10.187.162.143.139.114 50.262.236.218.210.185 30 30.211.186.167.162.138 10.172.148.132.129.105 50.234.213.195.191.167 10 30.190.169.152.149.125 10.156.135.121.118.096 0 0 0.135.116.103.081
5-33 Fixture With Globe, Hi-Bay Reflector and Without Guard Lamp: 150W high pressure sodium - (HPS) Total bare lamp lumens: 16,000 Fixture With Globe, Dome Reflector and Without Guard Lamp: 150W high pressure sodium - (HPS) Total bare lamp lumens: 16,000 NOTE: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS -.25; 70W HPS -.40; 100W HPS -.59. Multipliers are for use with candela curve only. Luminaire spacing ratio is 1.00. Coefficient of Utilisation Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff.Ceil. Wall 1 2 3 4 5 50.688.618.573.531.494 80 30.651.592.542.495.455 10.636.569.517.468.427 50.655.608.566.525.487 70 30.639.583.536.491.452 10.525.564.513.464.425 50.629.587.550.511.476 50 30.616.568.525.482.446 10.606.550.505.459.422 50.606.569.535.498.466 30 30.597.554.514.474.438 10.588.539.497.454.418 50.586.533.522.487.457 10 30.578.539.504.466.433 10.570.528.489.449.413 0 0.560.517.479.439.404 % Reflectance Room Cavity Ratio Eff.Ceil. Wall 6 7 8 9 10 50.460.427.396.369.328 80 30.420.388.358.330.288 10.394.361.330.303.262 50.455.423.392.366.325 70 30.418.385.356.328.288 10.391.359.329.303.262 50.444.414.385.360.320 50 30.412.380.352.325.285 10.388.357.328.301.261 50.436.406.379.354.315 30 30.407.377.348.322.282 10.385.354.326.300.259 50.428.400.373.348.311 10 30.402.373.345.319.280 10.382.352.324.298.258 0.373.343.315.290.249 NOTE: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS -.25; 70W HPS -.40; 100W HPS -.59. Multipliers are for use with candela curve only. Luminaire spacing ratio is 1.00. Coefficient of Utilisation Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff.Ceil. Wall 1 2 3 4 5 50.716.637.568.507.455 80 30.689.596.519.452.398 10.666.561.480.410.355 50.700.624.559.498.446 70 30.675.585.512.447.393 10.653.555.476.407.353 50.668.598.538.479.432 50 30.648.567.498.435.385 10.631.539.466.400.349 50.640.575.518.463.417 30 30.625.549.485.425.376 10.610.526.457.394.344 50.615.554.500.447.404 10 30.602.532.472.415.369 10.590.513.448.388.339 0 0.575.498.434.373.326 % Reflectance Room Cavity Ratio Eff.Ceil. Wall 6 7 8 9 10 50.413.373.339.312.275 80 30.355.318.285.258.222 10.316.280.246.221.187 50.405.368.334.308.271 70 30.352.314.283.256.222 10.312.277.245.221.187 50.392.356.324.299.264 50 30.345.307.277.252.217 10.309.274.243.219.185 50.380.345.316.291.257 30 30.338.303.272.247.214 10.306.270.241.217.183 50.369.337.307.283.251 10 30.331.298.267.244.210 10.301.267.238.215.181 0 0.292.257.227.204.170
5-34 NVMV Champ HID Fixtures Integral Ballast Non-Sparking, ExnR, IIC, IP66 Zone 2 Combustible Dust Zone 21 & 22 Application: Used in locations where a concentration of hazardous gases liquids or vapours may occur for short periods of time at infrequent intervals Used in hazardous locations where combustible dusts, fibres or flyings may be present Used where maintenance access is difficult and extended periods between relamping is required Ideal for processing plants, waste and sewage treatment facilities security lighting, roadways, garages & other heavy industrial applications Used where space is limited and high levels of lighting are required Features: All Units: Several mounting arrangements: Pendant Ceiling for flush to surface mounting Wall bracket-through feed Stanchion - 25 angle Integral long-life ballast Choice of light source - mercury vapour (MV), high pressure sodium (HPS) or metal halide Operating ambient temperature between minus 45 C and 55 Attractive gray polyurethane paint finish Configured glass and prismatic refractors reduce glare and improve light distribution Recessed hubs Restricted breathing design gives improved T Rating allowing use of higher lumen output fixtures Special Exn terminals to ensure positive connection to circuit wiring Standard Materials: Ballast housings and mountings - copper free aluminium (less than 0.4 of 1%) Guards - copper free aluminium or stainless steel wire Exterior hardware - stainless steel Globes - configurated glass Reflectors - dome or angle white Krydon fibreglass - reinforced polyester material Reflector lens assy - Alzak aluminium reflector, tempered glass lens Ceiling mount with dome reflector Standard Finishes: Aluminium ballast housings, mountings and aluminium guards... grey polyurethane paint Stainless steel wire guards... natural Reflectors... natural Options: (Refer to ordering information) Corro-free powder polyester coating, information available on request Quartz auxiliary lamp to provide light during the period required for HID lamps to restrike following resumption of power after a power failure - Large body fixtures only Instant restrike ballast - enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. Available for use with 50-150W HPS LX only Large body for improved T Rating on 250 Watt fixtures For application subject to extreme thermal shock, Tuff-skin coated G34 and G251 glasses are available Non-standard supply voltage and frequency, consult factory Fuse - to protect against abnormal line conditions and provide additional circuit protection Other entries available upon request Electrical Rating: 240V 50Hz 70 to 400W P.F. 0.9 Compliances: AS2380 Electrical equipment for explosive atmospheres - Non- Sparking Equipment, & Dust Excluding Ignition Proof AS 1939... Degrees of protection IP66 EN50021:1999 Certificate of Compliance No. - Ex426 - PTB00 ATEX 2215 Dimensions: See Pages 6-8 to 6-9 Photometric Data: See Pages 6-10 to 6-13 Accessories: See Page 5-38
5-35 Ordering Information NVMV S 1 M C 40 6 P I 0 0 Product Group NVMV- Champ Lamp Type S - HPS H - MV M - MH Wattage 07-70W 08-80W 10-100W 12-125W 15-150W 17-175W 25-250W 40-400W Entry Size 1-20mm / 1/2" 2-25mm / 3/4" 3-32mm / 1" 4-1 1/4" 5-1 1/2" Entry Thread M - Metric N - NPT B - BSP Mounting C - Ceiling W - Wall J - Stanchion Special Options 0 - Standard S - Fuse Voltage & Frequency 2-120V / 60Hz 3-220V / 50Hz 4-220V / 60Hz 5-230V / 50Hz 6-240V / 50Hz Guard 0 - Without Guard P - Guard R - RD4A Instant Restrike 0 - None / Small Body I - IR L - Large Body Options 0 - Standard 1 - Offshore Paint R - Red Body
5-36 Ordering Information Mercury Vapour (M/V) 240V/50Hz* High power factor reactor ballast (.9) Large body ceiling mount with RD4A reflector lens assembly Entry Lamp With Glass and Guard With Reflector Lens Assy. Size Watts Cat. No. Cat. No. Ceiling/Pendant Mount 20mm 80 NVMVH1MC086P000-25mm 80 NVMVH2MC086P000-20mm 100 NVMVH1MC106P000-25mm 100 NVMVH2MC106P000-20mm 125 NVMVH1MC126P000-25mm 125 NVMVH2MC126P000-20mm 175 NVMVH1MC176P000 25mm 175 NVMVH2MC176P000 20mm 250 NVMVH1MC256P000 NVMVH1MC256RL00 25mm 250 NVMVH2MC256P000 NVMVH2MC256RL00 20mm 400 NVMVH1MC406PL00 NVMVH1MC406RL00 25mm 400 NVMVH2MC406PL00 NVMVH2MC406RL00 Wall Mount 20mm 80 NVMVH1MW086P000-25mm 80 NVMVH2MW086P000-20mm 100 NVMVH1MW106P000-25mm 100 NVMVH2MW106P000-20mm 125 NVMVH1MW126P000-25mm 125 NVMVH2MW126P000-20mm 175 NVMVH1MW176P000-25mm 175 NVMVH1MW176P000-20mm 250 NVMVH1MW256P000 NVMVH1MW256RL00 25mm 250 NVMVH2MW256P000 NVMVH2MW256RL00 20mm 400 NVMVH1MW406PL00 NVMVH1MW406RL00 25mm 400 NVMVH2MW406PL00 NVMVH2MW406RL00 Stanchion Mount 1 1/4" BSP 80 NVMVH4BJ086P000-1 1/4" BSP 100 NVMVH4BJ106P000-1 1/4" BSP 125 NVMVH4BJ126P000-1 1/4" BSP 175 NVMVH4BJ176P000-1 1/4" BSP 250 NVMVH4BJ256P000-1 1/4" BSP 400 NVMVH4BJ406PL00 -
5-37 Ordering Information High Pressure Sodium (HPS) 240V/50Hz* High power factor reactor ballast (.9) with solid state ignitor With Glass With Reflector Entry Lamp And Guard & Lens Assy. Size Watts Cat. No. Cat. No. Ceiling / Pendant Mount 20mm 70 NVMVS1MC076P000-25mm 70 NVMVS2MC076P000-20mm 100 NVMVS1MC106P000-25mm 100 NVMVS1MC106P000-20mm 150 NVMVS1MC156P000-25mm 150 NVMVS2MC156P000-20mm 250 NVMVS1MC256P000 NVMVS1MC256RL00 25mm 250 NHMVS2MC256P000 NVMVS2MC256RL00 20mm 400 NVMVS1MC406PL00 NVMVS1MC406RL00 25mm 400 NVMVS2MC406PL00 NVMVS2MC406RL00 Wall Mount 20mm 70 NVMVS1MW076P000-25mm 70 NVMVS2MW076P000-20mm 100 NVMVS1MW106P000-25mm 100 NVMVS2MW106P000-20mm 150 NVMVS1MW156P000-25mm 150 NVMVS2MW156P000-20mm 250 NVMVS1MW256P000 NVMVS1MW256RL00 25mm 250 NVMVS2MW256P000 NVMVS2MW256RL00 20mm 400 NVMVS1MW406PL00 NVMVS1MW406RL00 25mm 400 NVMVS2MW406PL00 NVMVS2MW406RL00 Stanchion Mount 1 1/4" BSP 70 NVMVS4BJ076P000-1 1/4" BSP 100 NVMVS4BJ106P000-1 1/4" BSP 150 NVMVS4BJ156P000-1 1/4" BSP 250 NVMVS4BJ256P000 NVMVS4BJ256RL00 1 1/4" BSP 400 NVMVS4BJ406PL00 NVMVS4BJ406RL00 Metal Halide (MH) High power factor reactor ballast (.9) with solid state ignitor Ceiling / Pendant Mount 20mm 175 NVMVM1MC176P000-25mm 175 NVMVM2MC176P000-20mm 250 NVMVM2MC256P000 NVMVM1MC256RL00 25mm 250 NVMVM2MC256P000 NVMVM1MC256RL00 20mm 400 NVMVM2MC406PL00 NVMVM1MC406RL00 25mm 400 NVMVM2MC406PL00 NVMVM1MC406RL00 Wall Mount 20mm 175 NVMVM1MW176P000-25mm 175 NVMVM1MW176P000-20mm 250 NVMVM1MW256P000 NVMVM1MW256RL00 25mm 250 NVMVM1MW256P000 NVMVM1MW256RL00 20mm 400 NVMVM1MW406PL00 NVMVM1MW406RL00 25mm 400 NVMVM1MW406PL00 NVMVM1MW406RL00 Stanchion Mount 1 1/4" BSP 175 NVMVM4BJ176P000-1 1/4" BSP 250 NVMVM4BJ176P000 NVMVM4BJ256RL00 1 1/4" BSP 400 NVMVM4BJ176PL00 NVMVM4BJ406RL00 Please refer to page 5-30 for other configurations
5-38 Accessories GLASSES Configured Lamp Fixture Glass Size Cat. No. Type 70-250W G34 Heat (No Guard) Resistant G251 Heat (With Guard) Resistant 400W G303 Heat Resistant REFLECTORS Lamp Size Cat. No. Type 70-250W RD70 Dome RA70 30 Angle 400W RD739 Dome (Large Body) RA739 30 Angle REFLECTOR/LENS Lamp Size Cat. No. 400W RD4A GUARDS Lamp Suits Glass Guard. Size Cat No. Cat No. 70-250W G251 P22 250W (Large Body) G303 P33 400W G303 P33 Temperature Classification: Power Mercury High Pressure Metal Rating (W) Vapour (MV) Sodium (HPS) Halide (MH) G34 G303 G251 G34 G303 G251 G34 G303 G251 70 - - T5 T5 - - 80 T4 T4 - - - - 100 T4 T4 T4 T3 - - 125 T4 T3 - - - - 150 - - T4 T3 - - 175 (small body) T3 T3 - - T3 T3 175 (large body) T4 250 (small body) T3 T2 T3 T2 T3 T2 250 (large body) T3 T3 T3 400 T2 T3 T2 400 (using sealed T3 T4 T3 reflector/glass RD4A) Note: Light fixtures up to 250W use small body. 400W fixtures use large body 250W can be supplied in large body to give improved T rating - Please refer to table on
5-39 NFMV Industrial Floodlight Luminaires Application: NFMV floodlights are suitable for use in: Outdoor locations such as those found in process plants, manufacturing plants, loading and storage areas, petrochemical, waster or sewerage treatment plants Features: Enclosed and gasketed for wet locations Choice of HID light sources including HPS; 70, 100, 150, 250, & 400 MV; 175, 250 & 400 MH;175, 250 & 400 Versatile yoke mounting bracket simplifies installation Slipfitter adaptor available for 2 pole top mounting Door frame is hinged and has captive fastening screws for ease of relamping Silicone rubber gaskets are standard, ensuring long life and reliable environmental sealing even under adverse conditions Die cast aluminium exterior components are epoxy powder coated for superior corrosion resistance Corrosion resistant stainless steel external hardware Standard Materials: Housing and door frame...die cast aluminium Lens... tempered heat and impact resistant glass Gasket... extruded silicone Exterior hardware... stainless steel Standard Finishes: Grey epoxy powder coated Electrical Rating: 240 50Hz 70 to 400 watts Other voltages and frequencies available on request Compliances: AS2380.9 Exn AS 2236... 1994 DIP EN50021 Certificate of Compliance No. - Aus Ex 3562 - PTB 00 Atex 2214 Non-Sparking, Exn R, IIC, IP66 Zone 2 Combustible Dust Zone 21 & 22 Ordering Information: Cat No. Mercury Vapour NFMVH1MY4060000 T3 400W MV NFMVH1MY2560000 T3 250W MV NFMVH1MY1760000 T4 175W MV High Pressure Sodium NFMVS1MY4060000 T3 400W HPS NFMVS1MY2560000 T4 250W HPS NFMVS1MY1560000 T5 150W HPS NFMVS1MY1060000 T5 100W HPS NFMVS1MY0760000 T6 70W HPS Metal Halide NFMVM1MY4060000 T3 400W MH NFMVM1MY2560000 T4 250W MH NFMVM1MY1760000 T4 175W MH Mounting Accessory Slipfitter SFA6 - M20 SFA6 / 2M - M25 NFMV showing SFA6 slipfitter adaptor and gland (order separately)
5-40 Ordering Information NFMV S 1 M Y 40 6 0 0 0 0 Product Group NFMV - Floodlight Lamp Type S - HPS H - MV M - MH Wattage 07-70W 08-80W 10-100W 12-125W 15-150W 17-175W 25-250W 40-400W Entry Size 1-20mm / 1/2" 2-25mm / 3/4" 3-32mm / 1" 4-1 1/4" 5-1 1/2" Entry Thread M - Metric N - NPT B - BSP Mounting C - Ceiling W - Wall J - Stanchion Voltage & Frequency 1-110V / 60Hz 2-120V / 60Hz 3-220V / 50Hz 4-220V / 60Hz 5-230V / 50Hz 6-240V / 50Hz 7-227V / 60Hz 0 - NFMV Instant Restrike 0 - None I - IR Special Options 0 - Standard S - Fused Options 0 - Standard 1 - Offshore Paint R - Red Body
5-41 Photometric Data & Dimensions Lamp: 400W metal halide (M / H) Total bare lamp lumens: 34,000 For 250 watt clear metal halide, multiply lux values by 0.6 Lamp: 400W high pressure sodium (HPS) Total bare lamp lumens: 50,000 For 150 watt HPS, multiply lux by 0.32. For 250 watt high pressure sodium, multiply lux values by 0.6 Dimensions (mm) 430 175 65 450 660 530 390 Ratio of Distance to Mounting Height Ratio of Distance to Mounting Height Ratio of Distance to Mounting Feet Ratio of Distance to Mounting Feet Isolux Values at Various Mounting Heights (Lux values for both charts) Mounting Height A B C D E 5m 86.0 43.0 21.52 8.61 4.30 6m 18.42 24.75 11.84 5.38 2.47 7m 31.20 15.06 7.53 3.23 1.51 9m 21.52 10.76 5.38 2.15 1.08 11m 16.14 7.53 4.30 1.61 0.75 12m 11.84 6.46 3.23 1.18 0.65 Fixtures located at 0 0, 0 0 Aiming angle at 45 0 Fixture aiming angle 30 0 past vertical through 60 0 before vertical EPA Data - Aiming Angle 0 0 = 2.9 30 0 = 2.5 45 0 = 2.5 10 120 20mm Entry 2 Holes ø15 Mounting Details
5-42 FSFB 301 Flashing Beacon Application: The FSFB flashing beacon can be used as: as an obstruction marker as a visual alarm signal in areas which may be hazardous due to the presence of flammable liquids, gases or vapours,and dusts Features: Solid state beacon means no moving parts to wear out or fail Flametight threaded joints O-ring gaskets for weatherproofing Lightweight, copper free aluminium principal parts Easy to assemble Standard Materials: Body... Copper free cast aluminium Dome... Heat and impact resistant glass Beacon...Solid state strobe light Standard Finish: Grey polyurethane Options: Cast aluminium guard...cat. No. EV505 Special paint or protective finishes... specify Other colours: Clear, Green, Blue, Amber. Add C, G, B or A to Cat. No. when ordering Pendant entry... specify size & thread form Compliances: AS2480 Electrical equipment for explosive atmospheres - Flameproof enclosure AS2236 - Electrical equipment for explosive atmospheres. Dust excluding Ignition - proof AS1939 - Degrees of Protection IP65 Certificate of Compliance No. Ex491 Ordering Information: FSFB201 / Voltage / Colour Example FSFB20124R = 24 Volt red Technical Data: Supply Flash Rate Light Output Conduit Entries 2 x 20mm (1 Plugged) 24V DC 240V AC 60 FPM 2.25 Joules per flash Flameproof, Exd, IIC, IP66 Zone 1 Combustible Dust Zone 21 & 22 Dimensions:
5-43 FRFB 301 Rotating Beacon Application: The FRFB rotating beacon can be used as: as an obstruction marker as a visual alarm signal in areas which may be hazardous due to the presence of flammable liquids, gases or vapours, and dusts Features: Flametight threaded joints O-ring gaskets for weatherproofing Lightweight, copper free aluminium principal parts Easy to assemble Standard Materials: Body.. Copper free cast aluminium Dome... Heat and impact resistant glass - red Beacon...Lamp size 70 W quartz Halogen / 24V DC 55W quartz Halogen / 12V DC 25W incandescent / 240V AC Add 12, 24 or 240 to Cat. No. when ordering Standard Finish: Grey polyurethane Options: Cast aluminium guard...cat. No. EV505 Special paint or protective finishes... specify Other dome colours: Clear, Green, Blue, Amber. Add C, G, B or A to Cat. No. when ordering Pendant entry... specify size & thread form Compliances: AS2480 - Electrical equipment for explosive atmospheres - Flameproof enclosure AS2236 - Electrical equipment for explosive atmospheres. Dust excluding Ignition - proof AS1939 - Degrees of Protection IP65 Certificate of Compliance No. Ex491 Technical Data: Supply 12/24V DC 240V 50HZ AC Flash Rate 150 RPM Conduit Entries 2 x 20mm (1 Plugged) Ordering Information: FRFB301 / Voltage / Colour Example FRFB30124R = 24 Volt red Flameproof, Exd, IIC, IP66 Zone 1 Combustible Dust Zone 21 & 22 Dimensions:
5-44