SIMATIC S7-1200 Update to the S7-1200 System Manual, edition 04/2012 Product Information



Similar documents
Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

How many high-speed counters (HSCs) are provided by the SIMATIC S PLC? SIMATIC S FAQ March Service & Support. Answers for industry.

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

The goal is to program the PLC and HMI to count with the following behaviors:

LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4

Service & Support. How can you establish a connection between an S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

Cover PROFINET IO. Code Reader System SIMATIC MV440 / MV420. FAQ June Service & Support. Answers for industry.

IMPORTANT PRODUCT INFORMATION

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

Service & Support. How can you establish a connection between a S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

CPUs - CPU PN/DP

Profinet to EDV111 Series LED Signs Siemens Function Block Software Manual

TECHNICAL NOTE TNOI34

Automation License Manager

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

S and STEP 7 Basic V10.5

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

1 Application Description Objective Goals... 3

DB Administration COMOS. Platform DB Administration. Trademarks 1. Prerequisites. MS SQL Server 2005/ Oracle. Operating Manual 09/2011

SIMATIC S Basic Controller in the TIA Portal

SIMATIC HMI. WinCC flexible Getting Started First Time User. Order number 6ZB5370-1CL02-0BA2. Edition 04/2006 A5E

Service & Support. How do you configure time synchronization using the NTP procedure (without SICLOCK) for small PCS 7 plants?

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

1. TIB388 about the Windows compatibility of all Mutoh devices subdivided in

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

Sierra Wireless AirCard Watcher Help for Mac OS X

Applications & Tools. Migration to TIA Portal. WinCC Basic / Comfort / Advanced STEP 7 V5.x / WinCC flexible 2008 SP3. Migration Guide September 2013

How to read this guide

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

HTML Code Generator V 1.0 For Simatic IT Modules CP IT, IT, IT

Modicon M580 Change Configuration On The Fly User Guide

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

Cover sheet. Software Update from PCS 7 V7.1 SP3 to PCS 7 V7.1 SP4 SIMATIC PCS 7. FAQ September Service & Support. Answers for industry.

Modicon M340 Firmware

Application Note Profinet Modules

Phone: Fax: Web: info@ctiautomation.net

Siemens AG. SIMATIC S7 Ethernet 04/

SIMATIC. TIA Portal STEP 7 Basic V10.5. TIA Portal Introduction 1. Simple example 2. Extended example 3. Example "PID control" 4. Example "Motion" 5

IX Support Tool Setting Manual

Commissioning IDENTControl Compact IC-KP2-2HB17-2V1D Profinet Protocol with a Siemens S7 PLC

SIMATIC NET PC Software V8.2 SIMATIC NET. PG/PC - Industrial Ethernet / PROFIBUS SIMATIC NET PC Software V8.2. Introduction 1

BIGPOND ONLINE STORAGE USER GUIDE Issue August 2005

Historian SQL Server 2012 Installation Guide

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

Transferring AIS to a different computer

Installing and Configuring SQL Express 2008 R2 for Supply Chain Guru

Practice Fusion API Client Installation Guide for Windows

McAfee Content Security Reporter Software

Web server SIMATIC. S Web server. Preface. Documentation guide. General information. Websites 3. Function Manual 12/2014 A5E AD

Setting/Monitoring Tools for the C Controller Module Version 4 Operating Manual -SW4PVC-CCPU-E

DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface

Unity Pro. Unity Loader User Manual 07/2008 eng

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

SIMATIC HMI. WinCC flexible 2005 Transfer. Basic principles. Transferring and back transfer of a project. Managing Files on the HMI Device.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

SIMATIC. S7 Graph V5.1 for S7-300/400 Programming Sequential Control Systems. Preface, Contents. Product Overview. Installation and Authorization

Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power

Modicon M340 Peripheral Remote I/O Adapter BMX PRA 0100 User Manual

RecoveryVault Express Client User Manual

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Continuous PROFIBUS PA Instruments and Step 7. Configuring a Siemens Continuous Level PROFIBUS PA device in a S7-300 or S7-400 PLC

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

SKP16C62P Tutorial 1 Software Development Process using HEW. Renesas Technology America Inc.

Online Backup Linux Client User Manual

Online Backup Client User Manual

Web Designer for Modicon M340, Premium and Quantum

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

S SIMATIC S Welcome. Automation task. Hardware section 2. Software section 3. Security. Getting Started 05/2014 A5E AC

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

ATTO ExpressSAS Troubleshooting Guide for Windows

Reconfiguring VMware vsphere Update Manager

PROFINET IO Diagnostics 1

QUANTIFY INSTALLATION GUIDE

1. Product Information

Online Backup Client User Manual Linux

The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example. Select [Project] [New].

SIMATIC. S Getting started with S Preface. Quick review 1. Installation 2. Create a simple latch circuit 3. Complete the user program 4

SIMATIC S Workshop. Unrestricted / Siemens AG All Rights Reserved.

Technical Brief High Availability Policy Server

Table of Contents. FleetSoft Installation Guide

Migrating MSDE to Microsoft SQL 2005 Express SP4

Bellplast S.R.L. Informe del Dpto. Técnico

Troubleshooting Sprint Mobile Broadband USB Modem by Novatel Wireless TM (Ovation TM U727)

Introweb Remote Backup Client for Mac OS X User Manual. Version 3.20

CW Configurator Operating Manual -SW1DND-RCCPU-E


Transcription:

SIMATIC S7-1200 Product Information In spite of efforts to ensure the accuracy and clarity in the product documentation, some of the pages in the S7-1200 Programmable Controller System Manual contain information that has been identified as being incomplete, incorrect or misleading. New modules for the S7-1200 New modules expand the power of the S7-1200 CPU and provide the flexibility to meet your automation needs: New and improved CPUs: New CPU 1215C DC/DC/DC, CPU 1215C DC/DC/Relay, and CPU 1215C AC/DC/Relay offer 100 Kbytes of work memory, dual Ethernet, and analog outputs. New and improved CPU 1211Cs, CPU 1212Cs, and CPU 1214Cs have faster processing time, the possibility of 4 PTOs (the CPU 1211C requires a signal board), increased retentive memory (10 Kbytes), and increased time-of-day hold up time (20 days). New I/O signal module: SM 1231 AI 4 x 16-bit provides higher sample rate and increased number of bits. New battery board (BB 1297) offers long term backup of the real-time clock. The BB 1297 is pluggable in the signal board slot of the S7-1200 CPU (firmware V3.0 and later versions). Prerequisites To use the new modules you must use STEP 7 V11 SP2 Update 3 or later (Basic or Professional) and you must download the hardware support package (HSP) for new modules from the STEP 7 Options > Support Packages menu command. Follow the instructions for adding modules to the hardware catalog for STEP 7 (TIA Portal) from the Siemens Service and Support Site (http://support.automation.siemens.com). S7-1200 behavior following a fatal error When the S7-1200 CPU detects a fatal error, it enters a defective state and performs the following actions: 1. Turns on the error LED: When the CPU goes defective, it attempts to signal the condition by flashing the error LED. Note: The defective state of the CPU, however, might prevent the CPU from flashing the error LED. 2. Performs a warm restart, which removes the user program, hardware configuration and resets all outputs to 0. Note A defective state is not a STOP state or non-fatal error state where the user program remains and restores outputs to their substitute values. Securing access to the S7-1200 CPU As described in the Chapter 11, Web Server, section 11.1 "Enabling the Web server" in the S7-1200 Programmable Controller System Manual, take care to avoid unauthorized access to the CPU from the Web server interface. In addition to the security practices described in the topic "Enabling the Web server", also ensure that you isolate the CPU network behind a firewall. Siemens, All rights reserved P 2012 A5E03929122-AB, 07/2012 1

Incorrect HSC configuration after CPU version change The S7-1200 CPU V3.0 does not require a high-speed counter for correct PTO operation. However, previous firmware versions of the S7-1200 CPU (V1.0 or V2.x) do require an associated high-speed counter. It is possible to encounter compile errors when exchanging CPUs between V3.0 and V1.0 or V2.x. The following are specific scenarios that exhibit this behavior. Scenario: PTO and motion V1.0 or V2.x to V3.0 When you have an S7-1200 CPU V1.0 or V2.x with enabled PTOs and select to exchange this CPU with a CPU that supports V3.0, compile errors result from improperly configured high-speed counters due to differences in the operation of PTO. After the exchange, the resulting compile error appears as follows: To eliminate the compile error, follow these steps: 1. Double-click on the error in the compile output listing. The properties of the high-speed counter are displayed: 2. Select the "Type of counting" field and select one of the available options ("Frequency" or "Count"). The entry is no longer red. 3. Next, select the "General" section of the properties, as shown below: 2 A5E03929122-AB, 07/2012

4. Deselect the "Enable this high-speed counter" checkbox. The high-speed counter is no longer needed for correct PTO operation. 5. Recompile your project and verify that the compile succeeds. Scenario: PTO V3.0 to V1.0 or V2.x When you have an S7-1200 CPU V3.0 with enabled PTO and select to exchange this CPU with a CPU that only supports older firmware version (V1.0 or V2.x), compile errors result from improperly configured high-speed counters due to differences in the operation of PTO. The resulting compile error appears as follows: To eliminate the compile error, follow these steps: 1. Double-click on the error in the compile output listing. The properties of the pulse output appear as follows. 2. Set the "Pulse generator" to "PWM", select another field, then select the "Pulse generator" field and change it back to "PTO". This causes the associated high-speed counter to be configured correctly if it is not already in use. 3. Recompile your project and verify that the compile succeeds. A5E03929122-AB, 07/2012 3

Note If you configured an associated high-speed counter for "counting" or "frequency", a compile error is still shown. You need to make changes to your program in order to use PTO. Scenario: Enabled motion control V3.0 to V1.0 or V2.x When you have an S7-1200 CPU V3.0 using motion functionality and select to exchange this CPU with a CPU that only supports older firmware version (V1.0 or V2.x), compile errors result from improperly configured high-speed counters and motion control support. Motion Support V1.0 PLC V1.0 Motion V2.x PLC V1.0, 2.0 Motion V3.0 PLC V1.0, 2.0, 3.0 Motion The resulting compile error appears as follows: To eliminate the compile error, follow these steps: 1. Select the "Properties" tab for the PLC 2. Select the "high-speed counter" for the Axis configured and enable it. HSC1 must be associated with Axis 1 HSC2 must be associated with Axis 2 Note V1.0 and V2.x only support two (2) axes of motion. V3.0 supports four (4) axes of motion. When converting from V3 to V1.0 or V2.x, you must delete axes not assigned to PTO1 or PTO2 from the project prior to download. 3. Expand the "high-speed counter" and select "Axis" as the "Type of counting". Do this for each axis. 4 A5E03929122-AB, 07/2012

4. Save and recompile your project. If you have used V3.0 motion elements in the program, a compile error occurs. 5. Open the "Instruction Tree" and select the appropriate version for the PLC being used. Appropriate versions are indicated when the motion instructions are selectable. 6. You must replace all blocks with the version-appropriate motion instructions. 7. Recompile and download the project. Incomplete password configuration If you select a protection level other than "No Protection" but do not specify a password or a matching password, then a compile error results. However, if you select compile again, the compile error is cleared and you are allowed to download the project. The level of protection that was selected is put in place, but you cannot access the protected functions of the PLC because a valid password cannot be entered. You must clear the PLC by using an empty transfer card. For more information about how to create and use an empty transfer card, refer to Chapter 4, PLC concepts, section 4.5.3 "Transfer card" of the S7-1200 Programmable Controller System Manual. String or array compile error If you cannot successfully compile program blocks containing strings or arrays which successfully compiled in a previous version of STEP 7, an error results. A5E03929122-AB, 07/2012 5

Right-click "Program blocks" in the project tree and select "Compile" and "Software (rebuild all blocks)". Modifying Real value tags from the Web server WARNING Using the Variable Status Web page to modify Real data type tags with non-floating point values (for example, hexadecimal values) can produce unintended value modifications. Modifying PLC data with unintended values can cause unexpected machine or process operation which could result in death, serious injury or property damage. When you modify values for a PLC tag or data block tag from the Variable Status standard Web page for a Real data type, be sure you enter floating point values that include a decimal point on the Variable Status Web page. Example For example, consider a project with the following tags: PLC tag table: "Tag_1", data type Real Data block: "Data_block_1".db_tag, data type Real When you enter these tags in the Address field of the Variable Status Web page, use floating point values in the Modify Value field, such as "10.0". Floating-point values have different internal representations than integer values or hexadecimal values. If you configure tags in STEP 7 to use Real data types, you must modify those tags as Real values in your STEP 7 user program, on the Variable Status Web page, and any other usage. Do not try to write hexadecimal representations into a Real tag from the Variable Status Web page. The Web server converts the hexadecimal value to a Real value, which is NOT the same internal bit representation as the hexadecimal value. Note If you modify values for an absolute memory address such as MD100 or DB1.DBD1, using non-floating point values on the Variable Status Web page does not produce unintended results. Because there is no associated data type, the Web server makes no conversion based on the STEP 7 data type and modifies the value exactly as you enter it. Unintended results can occur only when you use non-floating point values for PLC tags or data block tags of data type Real. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG 6 A5E03929122-AB, 07/2012 A5E03929122-AB, 07/2012